Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
JK-DVF-ACVandal-resistant Color Video Door Station
with Access Control KeypadPlatine vidéo couleur résistante au vandalisme
avec clavier à codes rétro-éclairéAntivandalisme deurpost met kleurencamera en
ingebouwd codeklavier
83799600 A P1009YZ
INSTALLATION & OPERATION MANUALMANUEL D’INSTALLATION ET D’UTILISATION
INSTALLATIE & GEBRUIKSHANDLEIDING
JK-DVF-AC
JK-DVF-AC_ENG.indd 1 2009/10/05 21:18:28
1
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Registered User Code List / Liste des codes utilisateur programmés / Lijst Codes Geregistreerde Gebruikers
group 1 / groupe 1 / groep 1 group 2 / groupe 2 / groep 2
RECORD OF SETTINGS AND REGISTRATION DETAILS FOR ACCESS CONTROL (Please make sure to write down your settings below.)AIDE MEMOIRE DES PROGRAMMATIONS ENREGISTREES POUR LE CLAVIER (Faire en sorte de bien noter vos réglages ci-dessous.)LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES VOOR CODEKLAVIER (Zorg ervoor uw instellingen hieronder op te schrijven.)
External output settingParamétrage de sortie externeActivering AlarmuitgangLockoutBlocageBlokkering klavierAuto-relockAuto-reverrouillageAutomatische hersluitingTimer-linked unlockingDéverrouillage lié à l'horlogeTijdsgebonden ontgrendelingOperation toneBip de fonctionnementZoemer klavier
Master codeCode maître HoofdcodeKey illumination timeTemporisation d'éclairageVerlichtingsduur klavier
secRelay output timeTemporisation des relaisRelais outputtijd
Relay 1Relais 1Relais 1
secRelay 2Relais 2Relais 2
sec
ONAAN
OFFUIT
ONAAN
OFFUIT
ONAAN
OFFUIT
ONAAN
OFFUIT
1 2 1&2
JK-DVF-AC_ENG.indd 1 2009/10/05 21:18:29
2
English
FrançaisNederlands
English
WARNING
(Negligence could result in death or serious injury to people)1. Theunitmustbeinstalledandwiredbyaqualified
technician. Having installation performed by an unqualifiedtechniciancouldresultinelectricshock.
2. Donotconnectanynon-specifiedpowersourcetotheV, V terminals, and do not install two power supplies in parallel to a single input. Fire, damage to the unit, or system malfunction could result.
3. The unit is not explosion-proof. Do not install or use neargasesorflammablematerials.Fireorexplosioncould result.
4. Donotdismantleoraltertheunit.Fireorelectricshockcould result.
5. Do not allow the wires or DC output terminals to be shorted.Fireorelectricshockcouldresult.
6. Existing wiring such as chime wiring, etc. may contain high voltage AC electricity. Damage to the unit or electricshockcouldresult.Wiringandinstallationshouldbedonebyaqualifiedtechnician.
CAUTION
(Negligence could result in injury to people or damage to property)1. Whenmountingtheunitonawall,installtheunitina
convenient location, but not where it could be jarred or bumped. Injury could result.
2. Donotinstallormakeanywireterminationswhilepower supply is plugged in. It can cause electrical shockordamagetotheunit.
3. Beforeturningonpower,makesurewiresarenotcrossedorshorted.Fireorelectricshockcouldresult.
4. Do not install the unit in any of the following locations. Fire,electricshock,orunittroublecouldresult.* Places subject to dust, oil, chemicals, hydrogen
sulfide(hotspring).* Places subject to moisture and humidity extremes,
such as bathroom, cellar, greenhouse, etc.* Places where the temperature is quite low, such
as inside a refrigerated area or in front of air-conditioner.
* Placessubjecttosteamorsmoke(nearheatingorcookingsurfaces).
* Wherenoisegeneratingdevicessuchasdimmerswitches, invertor electrical appliances, are closeby.
5. Do not put anything on the unit or cover the unit with cloth, etc. Fire or unit trouble could result.
GENERAL PRECAUTIONS
1. This product, being a control unit of door release, should not be used as a crime-prevention device.
2. This product is weather-resistant, but do not spray high-pressure water on it. Unit trouble could result.
3. The product becomes inoperative during power failure.4. As to other manufacturer's devices, such as sensor,
door releases, timer, used with this system, comply withtheSpecificationsandWarrantyconditionsmanufacturers or venders present.
5. Whenoutsidetemperaturelowerssharplyafterrainfall,etc., the inside of the camera may fog up slightly, causing a blurry picture, but this is not a malfunction. Normal operation will be restored when moisture evaporates.
6. Due to the environmental sound around the unit, it may hinder smooth communication, but this is not a malfunction.
RECORD OF SETTINGS AND REGISTRATIONDETAILS FOR ACCESS CONTROL ……………………… 1PRECAUTIONS …………………………………………… 2PACKAGE CONTENTS …………………………………… 3MOUNTING ………………………………………………… 3PART NAMES ……………………………………………… 4
WIRINGANDCONNECTIONS …………………………… 5FUNCTIONS/SETTING UP FOR ACCESS CONTROL … 7OPERATION OF ACCESS CONTROL ………………… 11TECHNICAL PRECAUTIONS ………………………… 11SPECIFICATIONS ……………………………………… 12WARRANTY ……………………………………………… 12
General Prohibitions Prohibition to Dismantle the Unit General Precautions
PRECAUTIONS
CONTENTS
ThankyouforselectingAiphoneforyourcommunicationandsecurityneeds.Pleasereadthismanualcarefullybeforeinstallation,andkeepitinasafeplaceforfuturereference.* Refer to the “INSTALLATION & OPERATION MANUAL” for the JK-1MED or JK-1MD for complete
information regarding this system.
JK-DVF-AC_ENG.indd 2 2009/10/05 21:18:31
3
Eng
lish
Fran
çais
Nede
rland
s
Door station with Flush mount back box Special screwdriver Transparent nameplate (x2) Installation & Operation manual
"Do not install this unit in any of the following locations where lighting or the ambient environment could impact the display on the video monitor due to the characteristics of the door station's camera."
a Locations subject to direct sunlight
b Under street lights or door lights
c Other locations subject to strong lighting or backlighting conditions
Wide picture
Zoom picture
The zoom position can be changed. (Refer to the master station's operation manual.) The factory setting is "Center" for Zoom mode.
Approx. 1,050 mm
(3' 5")
Approx. 700 mm (2' 3")
Approx. 900 mm (3')
Objects appear smaller due to greater distortion in the surrounding sections compared to the central section, but a wider area is displayed.
The display range is a rough estimation and may change due to the installation environment.
Up/Down Mounting position 1,500 mm (5')
Left/Right
Approx. 1,050 mm (3' 5")
Approx. 2,050 mm (6' 9")
Approx. 1,000 mm(3' 4")
500 mm (20")
1,500 mm (5')
Unit centerApprox. 1,850 mm
(6' 2")
Approx. 1,050 mm (3' 5")
Approx. 800 mm(2' 7")
Mounting position 1,300 mm (4' 3")
Unit center
1,300 mm (4' 3")
500 mm (20")
Approx. 170°
Left/Right
Up/Down
500 mm (20")
Zoom <Up>
Approx. 850 mm (2' 9")
Approx. 1,450 mm(4' 9")
500 mm (20")
Unit center
1,500 mm (5')
Approx. 700 mm (2' 3")
Approx. 1,200 mm (3' 11")
Zoom <Center> Zoom <Down>
Approx. 1,650 mm (5' 6")
Approx. 850 mm (2' 9")
500 mm (20")
Unit center
1,500 mm (5')
Zoom <Left> Zoom <Center> Zoom <Right>
500 mm (20")500 mm
(20")
Approx. 100 mm (4")
Approx. 1,300 mm (4' 3")Approx. 900 mm (3')
Approx. 1,300 mm (4' 3")
Approx. 100 mm (4")
Unit center
1,500 mm (5')
500 mm (20")
Wide picture
Zoom picture (when mounting position is 1,500 mm (5'))
500 mm (20")
An area over a range of approx. 170° in a 500 mm (20") radius from the camera displays.
(The display range is a rough estimation and may change due to the installation environment.)
Approx. 2,300 mm(7' 7") Approx. 1,900 mm
(6' 4")
Approx. 800 mm (2' 7")
PACKAGE CONTENTS
MOUNTING
Mounting locations
Mounting positions and image view area of Video door station
JK-DVF-AC_ENG.indd 3 2009/10/07 18:33:40
4
English
FrançaisNederlands
Special screws for panel mounting
CameraMicrophoneWhitelightLED
Speaker
Directory cardCall buttonLEDindicator(Orange)LEDindicator(Green)
Keys(Yellow)
Special screws for panel mounting
45 mm(1-3/4")
263 mm(10-3/8")
114 mm(4-1/2")
ABC
1.Detachthedoorstationfromtheflushmountbackboxbyremovingthescrewswiththespecialscrewdriverthatissuppliedwith the unit.
2.Attachtheflushmountbackboxtothewall.3.Routewiringthroughtheflushmountbackboxandconnectwirestothedoorstation.
* See page 5 and 6 for details on wiring and connections.4.Attachthedoorstationtotheflushmountbackbox.
* Besuretousetheoriginalscrewstoreattachthedoorstationtotheflushmountbackbox.
Notes on handling wires l Afterstrippingbackthecablejacketfromtheconductors,
waterproof the area that has been cut by wrapping insulation tapearoundtheendofthejacket.Additionally,positionthe cable downward to prevent rainwater or moisture from seeping into the cable.
l Do not bend the wires at a sharp angle to prevent them frombreakingastheyage.
Flushmountbackbox
Door station
Transparent nameplate
Special screwdriver
Specialscrews(4pcs)
Do not bend at a sharp angle.
Loosen
Tighten
Flush mount backbox
Areas where the cable jacketwasremoved
Wall
To insertion opening
Using the transparent nameplatesInserting the transparent nameplates1Removethedoorstationfromtheflushmountbackbox.2Peelofftheprotectivesealsontheplate(bothsides).3 Fill in the name of the resident on the transparent nameplate.
Besuretoleave25mm(1")ofwhitespaceontheleftendto account for insertion.
4Insertthefilled-intransparentnameplateatthespecifiedinsertionopeningontherearsideofthedoorstation(indicatedwith indiagram).
25 mm(1")
Video door station
Access control keypad
PART NAMES
Mounting
JK-DVF-AC_ENG.indd 4 2009/10/05 21:18:35
5
Eng
lish
Fran
çais
Nede
rland
s
Wiring distancePower supply Diameter Distance
A - 0.65mm(22AWG) 50m(165')
- 1.0mm(18AWG) 100m(330')
B 12 - 18V AC or DC or less
0.65 - 1.0 mm (22-18AWG)
100m(330')
18 - 24V AC or DC 0.65 - 1.0 mm (22-18AWG)
300m(980')
C - 0.65 - 1.0 mm (22-18AWG)
300m(980')
D - The connection distance will depend on thespecificationsoftheelectricdoorstrike,relaysorelectromagneticdoorlocktobeconnected. To determine the operating range,pleaserefertothespecificationsofeach terminal.
N/C contactPower supply
User group1 relay 1 User group2 relay 2Request to exit/entrybutton 1
Request toexit/entrybutton 2
N/C contact
N/O contact N/O contact
Power supply
Between 12 and 24V ACBetween 12 and 24V DC
Request to exit/entry button, Timer
Minimum overload : 100mV DC, 0.1mA or aboveContact capacity : 3V DC, 0.1A or above
Relay
24V DC, 3A (resistive load) 1A (inductive load)24V AC, 3A (resistive load) 1A (inductive load)
Minimum overload : 5V DC, 100mA or above
V V
A1 A2
PB1 PB2 C T NO1 C1 NC1 NO2 C2 NC2
TimerCommon
JK-1MDJK-1MED
A
B
2
2
2
2
2
2
2
2
CD
A1 A2
A1
A2
L
L
Master station
Video door station
Video door station
Access control keypad
Access control keypad
Power supply
Request to exit/entry button
Timer
Relay
Relay
Automatic gate
Electromagnetic doorlock Electricdoorstrike
or
Request to exit/entry button
or
or
WIRING AND CONNECTIONS
Outline of connections and wiring distance
Terminal names
(Terminals for Video door station)
(Terminals for Access control keypad)
JK-DVF-AC_ENG.indd 5 2009/10/05 21:18:37
6
English
FrançaisNederlands
n Connection of Relay 1 only
Electric door strike
AC transformer
Power supply
2 NP2 NP2 NP2 NP
2 NP
2
NP
2
NP
Automatic gate
Power supply
Request to exit/entry button(push button, etc.)
Electromagneticdoor lock
V V PB1 PB2 C T NO1 C1 NC1 NO2 C2 NC2 NO1 C1 NC1 N NO1 C1
PS
NC1 NO2 C
A1 A2
JK-1MDJK-1MED
JK-1MED/1MD
A1 A2 L L
JK-DVF-AC
n Relay 1: Automatic gate (N/O contact), Relay 2: Electric door strike (N/O contact)
Power supplyRatingBetween 12 and 24V ACBetween 12 and 24V DC
Automatic gate
Timer
For relay 2 Request to exit/entry button
For relay 1 Request to exit/entry button
To set the "auto-relock" / "External output by forced entry" function, a sensor (locally available) is required.
The request to exit/entry button for relay 2 cannot be used when the "auto-relock" / "External output by forced entry" functions are set.
Electric door strike
AC transformer
Auto-relock/External output by forced entry (sensor connection is required)
2
NP
2
NPA1 A2
JK-1MDJK-1MED
A1 A2 L L
V V PB1 PB2 C T NO1 C1 NC1 NO2 C2 NC2
Alarm, Security
Only connecting to the terminal of relay 2 is possible.
External outputNO2 C2
2 NP
2
NP
2
NP
2
NP
2 NP 2 NP
PB2
N.C
C
JK-DVF-AC
JK-1MED/1MD
or
or
or or
Example of electric door strikeconnection(N/O)
Example of automatic gateconnection(N/O)
Example of electromagnetic doorlockconnection(N/C)
Connection examples
JK-DVF-AC_ENG.indd 6 2009/10/05 21:18:39
7
Eng
lish
Fran
çais
Nede
rland
s
Thissectionexplainsthesettingsofeachfunction,includingthemastercodeformanagement,theusercodeforunlocking,thebuzzer and the LEDs. About the setting mode:Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for the desired function. After settings have been made, enter the following setting codes to continue the setting operation. Press to exit the setting mode.
Setting items Allowable setting range Default value Setting code Setting the code length
Change the length of the master code and the user code. )Theybothmustbethesamelength.
4, 5, or 6 digits 4 digits
Setting the master codeEnteramastercodeusingbetween4and6digits(alphaornumeric)toswitch to the setting mode. )Thenumberofdigitsinthecodecanbesetbysettingthecodelength.
1Validkeys:0-9,A,B
1234
Setting the code for user group 1Settheunlockingcodeforusergroup1.)Thenumberofdigitsinthecodecanbesetbysettingthecodelength.
Numberofcodes:60Validkeys:0-9,A,B
- -
Setting the code for user group 2Settheunlockingcodeforusergroup2.)Thenumberofdigitsinthecodecanbesetbysettingthecodelength.
Numberofcodes:40Validkeys:0-9,A,B
- -
Setting the key illumination timeSetthelengthoftimethatthekeyswillbelitupaftertheyarepressed.
Illuminationtime:10to99seconds, or continually lit
10 Sec.
Setting the relay 1 output timeSet the output time of relay 1.
Outputtime:1to99seconds, or latched
3 Sec.
Setting the relay 2 output timeSet the output time of relay 2.
Outputtime:1to99seconds, or latched
3 Sec.
Reset SettingsReturn all the settings to their default values.
- -
External output settingThe alarm or security system connected to the terminal of relay 2 will be activatedwhenthe"Lockout"*ortheforcedentry*iscarriedout.*"Lockout":RefertoVIIIbelow.*Forcedentry:Thisfunctionislinkedwiththedooropen/closesensor(N.C.)whichisconnectedtoPB2andC,andcarriedoutwhenopeningthedoorwithoutactivatingthisunit.(Forexample,entryinanimpropermanner,manualunlock,etc.))Ifthereisawaytoopenthedoorwithoutactivatingthisunit,suchas
manualunlock,donotmaketheexternaloutputsettingfortheforcedentry.
· OFF·DuringLockout· During forced entry output· Duringlockoutandforced
entry output
OFF
LockoutIf several incorrect access codes are attempted, the code input function is disabled for a programmed period of time.
·When"Lockout"isactivated,theLED(Orange)indicatorandthekeypadblink,andthebuzzersoundsfor3seconds.Thisisjustasoundtoinformyou that the function has been activated. It is not a warning sound. If you want a warning to be sounded, please use the external output function to activate a commercially-available alarm device.
· Theunlockfunctionwillworkwhentherequesttoexit/entrybuttonispushed,evenwhilethe"Lockout"functionisoperating.
ON/OFFInvalidnumberoftimes: 10 to 99 timesInvalidtime: 10 to 99 seconds
OFF
Auto-relock (Anti-tailgate)Afterthedoorhasbeenlinkedtothedooropen/closesensor(N/C),andunlocked,itwillrelockitselfonesecondafterbeingclosed,thuspreventingthe entry of an unauthorized third party. 1
ON/OFF OFF
Timer-linked unlocking settingThesystemcanbesettounlockthedoorbypressingthe keywithinthesettimeandlinkingittotheexternaltimer(N/O).TheoperationsfortheLEDsandthebuzzerafterunlockingarethesameasthoseusedtoperformusercodeunlocking.Whenthedoorislinkedtothetimer,unlockingcanbeperformedusingtheusercodeandtherequesttoexit/entrybutton.Whenlatch output is performed for the relay settings, the relay turns ON/OFF every time the keyispressed.
Linkedrelay:relay1relay 2relay 1 and 2
0keyillumination:ON/OFF
Linkedrelay:relay1
0keyillumination:OFF
Operation tone settingsSetthetoneheardwhenthekeypadisbeingusedtoON/OFF.
ON/OFF ON
• Thesettingcanbesavedevenwhenthepowerisoff.• Thesystemcannotbeswitchedtothesettingmodewhiletherelayisunlocked.• Whenthesettingmodehasbeenactivatedandnooperationsareperformedforapproximately120seconds,thesystemwillexitthesettingmode.(Ifakeyispressedduringthattime,thetimerwillstartover.)
• Neithertherequesttoexit/entrybuttonnorthetimer-linkedunlocking keycanbeoperated,andunlockingusingtheuser code cannot be performed while the setting mode is activated.
• Thevolume(thechecktone,operationtone,etc.)fromthedoorstationmaybecomeloweraccordingtothemountingstatus.1 :Whentheauto-relockisused,therequesttoexit/entrybuttonforrelay2cannotbeused.Theoutputofrelay2is
onlypossiblewhenusercodeunlockingisperformed.
FUNCTIONS/SETTING UP FOR ACCESS CONTROL
JK-DVF-AC_ENG.indd 7 2009/10/05 21:18:42
8
English
FrançaisNederlands
Input the master code twice.(Default: )
- When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. (If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
(orange)Illumination
(green)Blinking
Orange (L) Green (R)
Bleep, Bleep
Indicator goes out Blinking
Bleep,Bleep
Inputting of user number (ex.: 01)
Inputting of code (ex.: 1006)* Numbers 0 - 9 and the
letters A and B can be used
Inputting of user number (ex.: 60)
Inputting of code (ex.: 04B2)* Numbers 0 - 9 and the
letters A and B can be used
· To make the set user code invalid, press 0000 (when 4 digits are used), 00000 (when 5 digits are used), or 000000 (when 6 digits are used). Code numbers which contain only "0" cannot be set as user codes.
· As the factory pre-setting master code is 1234, 1234 (when 4 digits are used), 12345 (when 5 digits are used), and 123456 (when 6 digits are used) cannot be set as user codes.
· Do not set simple codes, such as 1111.* The same code cannot be set for both the user code and the
master code. The previously set code has priority.
Setting the code
00 - 59 60 - 99
group 2
Blinks twiceBlinkingIllumination
Illumination
IlluminationBlinks twiceBlinkingIllumination Illumination
When a user code that has already been set is selected
When a user code that has already been set is selected
Blinking Illumination Blinking
group 1
Bleep,BleepBleep Bleep,
BleepBleep
Beep Beep
Illumination Blinking
Setting the master code(Default:1234)
Inputting of new master code (ex.: 4321)
Input the setting code.
· Please note that the shift to the setting mode can be performed during timer-linked unlocking. However, if " " is included in the master code, the door will be unlocked, and the shift to the setting mode will not be able to be performed.
· The same code cannot be set for both the user code and the master code (the previously set code has priority).
· Do not set simple codes, such as 1111.
· We recommend that you change the default master code.
Illumination Blinking
Beep
Bleep
Illumination Blinking
· The set code will be saved in memory, even if the code length is changed. However, codes of different lengths cannot be used.
· When the code length has been changed, the master code returns to the default value (if the number of digits in the code is 4, 5, or 6, the master code is 1234, 12345, or 123456 respectively).
Inputting of code length (ex.: 5 digits)4, 5, or 6 digits
Input the setting code.
Setting the code length(Default: 4 digits)
Illumination Blinking
Beep
Bleep
The result of each operation is indicated by the lighting up of the LED indicators located just abovethekeys,andbythesoundingofthebuzzer.
JK-DVF-AC_ENG.indd 8 2009/10/05 21:18:44
9
Eng
lish
Fran
çais
Nede
rland
s
· When the relay 1 output time is set to latched output, the auto-relock function is disabled.
· When the auto-relock function is turned on, the unlock function of the request to exit/entry button of relay 2 is disabled.
· If the 0 key illumination function is turned on while the timer is on, only the 0 key illumination will light up, even if the "key illumination time setting" is set to "Indicator is continually lit".
OFF ONOFF ON OFFOFF ONONOperation tone OFF
Operation tone ON
Operation tone OFF
Operation tone ON
Relays 1 and 2 are both linkedRelays 1 and 2 are both linked
Only relay 1 is linked
Input the setting code. Input the setting code. Input the setting code. Input the setting code.
Lockout(Default: OFF)
Auto-relock (Anti-tailgate)(Default: OFF)
Timer-linked unlocking setting(Default: relay 1, OFF)
Operation sound settings(Default: ON)
0 key illumination ONwhile timer is on
0 key illumination OFFwhile timer is on
0 key illumination ONwhile timer is on
0 key illumination OFFwhile timer is on
Inputting the number of operations (ex.:10 times)10 -99
Inputting length of time in "Lockout" mode (Ex.: 10 seconds)10 - 99
Input the master code twice.
(Default : )
Only relay 1 is linked
Only relay 2 is linked
Only relay 2 is linked
Beep
(orange)Illumination
(green)Blinking
Bleep, Bleep
Illumination BlinkingIllumination BlinkingIllumination Blinking Illumination Blinking
BleepBleepBleep Bleep
Illumination BlinkingIllumination Blinking Illumination Blinking
BleepBeep Beep
Illumination Blinking Illumination Blinking
Bleep
Illumination Blinking
Bleep
Illumination Blinking
Beep
Illumination Blinking
Beep
- When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.
(If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
Indicator goes out Blinking
Bleep,Bleep
External output setting(Default: OFF)
Input the setting code.
Illumination IlluminationBlinks three times Blinking
OFFOFFDuring lockout
and forcedentry output
DuringLockout
During forcedentry output
During lockoutand forced
entry output
Input the setting code.
Reset Settings
Illumination Blinking Illumination Blinking
(orange)Illumination
(green)BlinkingInput the master code twice.
(Default : )
DuringLockout
During forcedentry output
Bleep, Bleep, Beep Beep
Bleep, Bleep
Bleep Bleep
Inputting of relay output time (ex.: 99 seconds)01 - 99Latched (※) : 00
When setting relay 1When setting relay 1 When setting relay 2When setting relay 2
Setting the relay output time(Default: 3 Sec.)
Input the setting code. Input the setting code.
Illumination Blinking
Illumination Blinking
Beep
Bleep
Setting the key illumination time(Default: 10 Sec.)
Input the setting code.
Inputting of illumination time (ex.: 20 seconds)10 - 99Indicator is lit up at all times: 00
Illumination Blinking
Illumination Blinking
Beep
Bleep
- When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode. (If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
Indicator goes out Blinking
Bleep,Bleep
· If the power is turned off and the , , and keys are pressed simultaneously while the unlock 1 input status is active (short circuit between terminals PB1 and C), the settings can be returned to their default values by turning the power back on and pressing the , , and keys simultaneously for 3 seconds.
· When setting the external output, do not set the relay 2 output to be latched.
· (※) If the latched status has been set and the door is unlocked, it will not be locked again until the user code is entered (or the request to exit/entry button is pressed, or the key is pressed while timer-linked unlocking is set).
· When the door is unlocked during relay outputting (including when latched), the system cannot be switched to the setting mode.
JK-DVF-AC_ENG.indd 9 2009/10/05 21:18:50
10
English
FrançaisNederlands
· When the relay 1 output time is set to latched output, the auto-relock function is disabled.
· When the auto-relock function is turned on, the unlock function of the request to exit/entry button of relay 2 is disabled.
· If the 0 key illumination function is turned on while the timer is on, only the 0 key illumination will light up, even if the "key illumination time setting" is set to "Indicator is continually lit".
OFF ONOFF ON OFFOFF ONONOperation tone OFF
Operation tone ON
Operation tone OFF
Operation tone ON
Relays 1 and 2 are both linkedRelays 1 and 2 are both linked
Only relay 1 is linked
Input the setting code. Input the setting code. Input the setting code. Input the setting code.
Lockout(Default: OFF)
Auto-relock (Anti-tailgate)(Default: OFF)
Timer-linked unlocking setting(Default: relay 1, OFF)
Operation sound settings(Default: ON)
0 key illumination ONwhile timer is on
0 key illumination OFFwhile timer is on
0 key illumination ONwhile timer is on
0 key illumination OFFwhile timer is on
Inputting the number of operations (ex.:10 times)10 -99
Inputting length of time in "Lockout" mode (Ex.: 10 seconds)10 - 99
Input the master code twice.
(Default : )
Only relay 1 is linked
Only relay 2 is linked
Only relay 2 is linked
Beep
(orange)Illumination
(green)Blinking
Bleep, Bleep
Illumination BlinkingIllumination BlinkingIllumination Blinking Illumination Blinking
BleepBleepBleep Bleep
Illumination BlinkingIllumination Blinking Illumination Blinking
BleepBeep Beep
Illumination Blinking Illumination Blinking
Bleep
Illumination Blinking
Bleep
Illumination Blinking
Beep
Illumination Blinking
Beep
- When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.
(If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
Indicator goes out Blinking
Bleep,Bleep
JK-DVF-AC_ENG.indd 10 2009/10/05 21:18:53
11
Eng
lish
Fran
çais
Nede
rland
s
* Also refer to the “INSTALLATION & OPERATION MANUAL” for the master station (JK-1MED or JK-1MD) connected to this unit regarding the operation of the video door station.
A. Unlocking of user code Whentheregisteredusercodehasbeeninputusingthe
keypad(between4and6digits),theLEDindicator(group1:orange,group2:green)lightsup,thebuzzersounds,andtheelectricdoorstrikeisunlocked.
Orange LED lights up (during relay1 operation)
Green LED lights up (during relay2 operation)
ex.) group 11006
group 204B2
BeepBeep
• Thetimeintervalduringwhichthebuttonmustbepressed is approximately 10 seconds. If the time interval exceeds approximately 10 seconds, the input value will be cleared.
• Ifyoumakeamistakewheninputtingtheusercode,input the user code again.
• Whenthe"Lockout"functionhasbeenset,thereleasefunctionislockedandtheinputoperationisdisabledforthespecifiedtime(10-99seconds)ifinvalidcodesareinputasetnumberoftimes(10-99times).(Reference:"Lockout".)Duringthistime,thekeyilluminationwillblink4times,theLED(orange)indicatorwillblinkforthe set deactivation time, and the buzzer will sound for approximately 3 seconds.
B. Timer-linked unlocking Whenthetimer-linkedunlockingfunctionisactive,the
doorcanbeunlockedbypressingthe keyduringthesettime,whilethetimerislinked.
The keyilluminationlightsupwhenthetimerisactivated by performing the setting.
C. Unlocking using the request to exit/entry button Whenleavingthepremises,youcanactivatetheelectric
doorstrikebypressingtherequesttoexit/entrybuttonconnected to the unit. Pressing request to exit/entry button 1 releases relay 1, and pressing request to exit/entry button 2 releases relay 2.• Whenthedoorisunlockedusingtherequesttoexit/
entry button, the LED will not light up and the buzzer will not sound.
• Operatingtemperature:Between-10°Cand60°C(+14˚Fto140˚F)
• Cleaning:Cleantheunitwithasoftclothdampenedwitha neutral household cleanser. Do not use any abrasive cleanser or cloths.
• Theunitisweatherresistant.Howeverdonotsprayhighpressure water on the unit directly. Excessive moisture may cause problems with the unit.
• Pressandreleasethe , , , and keyssimultaneouslywhentheAccesscontroldoesnotwork.* TheLEDs(orangeandgreen)willblinkandthebuzzerwillsound,andthenresettingwilltakeplace.(Thesettingsdonotreturntotheirdefaultvalues.)
• Ifresettingdoesnotwork,contacttheservicetechnicianwho installed the unit.
OPERATION OF ACCESS CONTROL
TECHNICAL PRECAUTIONS
JK-DVF-AC_ENG.indd 11 2009/10/05 21:18:54
12
English
FrançaisNederlands
Aiphone warrants its products to be free from defects of material andworkmanshipundernormaluseandserviceforaperiodoftwo years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty.Aiphonereservesuntoitselfthesolerighttomakethefinaldecisionwhetherthereisadefectinmaterialsand/orworkmanship;andwhetherornottheproductiswithinthewarranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensationforanylossordamageincurredbythebreakdownor malfunction of its products during use, or for any consequent inconvenience or losses that may result.
FCCThis device complies with Part 15 of the FCC Rules. Operation issubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept any interference received, including interference that may cause undesired operation.
General• Dimensions: Doorstation:295(H)×144(W)×8(D)(recess:30)mm H11-5/8”xW5-3/4”xD5/16”,recess1-3/16” Flushmountbackbox:263(H)×114(W)×45(D)mm H10-3/8”xW4-1/2”xD1-3/4”• Weight: Doorstation:approx.890g(1.97lbs) Flushmountbackbox:approx.600g(1.3lbs)
Video door station• Powersupply: Suppliedfromthemasterstation• Cameraunit: Complementarymetaloxidesemiconductor (CMOS)
• Scanninglines:525lines• Minimumsubjectillumination:5Luxat50cm(1'6")distance
Access control keypad• Powersupply: 12-24VAC 12 - 24V DC• Powerconsumption:DC:Max.70mA AC:Max.100mA• Numberofrelaycircuits:2• Relaycontact:N/O,N/C• Relaycontactcapacity: 24VDC,3A(resistiveload) 1A(inductiveload) 24VAC,3A(resistiveload) 1A(inductiveload)
SPECIFICATIONS
WARRANTY