UTNA general features

INDEX General featur es page 3 Technical features page 6 Installation soluti ons page 8 Coil perfor mance page 10 Fan perfor mance page 28 Fan module page 32 Coil module page 33 Modules and accessories page 34 Accessories: electrical connecti on page 42

Conditions of use ○ UTNA units are modular air handling terminal units for horizontal ins tallati on, designed for ci vil air conditioning. ○ The appliance is designed for indoor installation. Construction features ○ Chassis made of galvanised sheet steel. Featuring completel y r emovable panels made of pre- painted (RAL 9002) sheet metal; including self-extinguishing heat and soundproof insulati on made of heat-bonded pol yester featuring Class 1 fire resistance and 40 kg/m3 density. ○ BA2R, B A4R, B A6R coil module complete with: pleated dual section filter (extractable from any direction) featuring G3 efficiency index; heat exchanger with finned coil, made of copper pipes and al umini um fins featuring 2-4-6 rows with r eversible right hand connections on the left; duct connecti on fitting; gravity feed condensate drain pan made of plastic on models 015-051 and gal vanised sheet metal on models 078-150 for BA4R and BA6R onl y. ○ SV fan module complete with dual intake centrifugal fan and IP55 direct coupled 3 speed motor on models 015÷038; IP55 2 speed motor on model 051; IP55 4 pole single speed motor with variable V-belt pulley coupling on models 078-150. Control board housed in a sealed box (IP55) on model 051- 078-107-130-150, completed with magnetoter mic switch and power contactor for the models 078- 107- 130-150. • On reques t the SV fan modul e on units 078÷150 is supplied with an IP55 three phase motor with 4/6 pol es or 4/8 pol es. ○ Power suppl y: 230V-1ph-50Hz on models 015÷038; 400V-3ph+N-50Hz on models 051÷150.

Page 4: K11142 ed.5 UTNA GB

44

UTNA general features

Accessory modules supplied separately PMA- Intake/delivery plenum made of pre-painted gal vanised sheet steel, with free front outlet for fixi ng KSER, KPBC, KPBM or KPCC accessories. SIL- Gal vanised and pre-pai nted sheet steel plenum featuring silencer with soundproofing cartridges to be fitted on the deli ver y or intake. MUV – Plenum with humidifier complete with linear steam distributor to be used in combinati on with the PR V el ectric external steam pr oducer. PRV – Electric external s team producer featuring immersed elec trodes (for the use of PRV in the models 015-020-029-038 buying the control board KQE is pr eferable).

Factory fitted accessories KB 2R - Additi onal water-filled heating coil made of copper pipes and alumini um fins, inserted in the BA modul e (models 078÷150 onl y). KR – Carbon steel el ectrical heater with zinc steel fi ns fitted i n the BA module (for models 078÷150 onl y) compl eted with control board with magnetothermic switch, 2 safety thermostats, power contactors and user terminal board. KSER – Conjugated damper made of galvanised s teel for air renewal (25% max.) and air recirculation. Fixed to the PMA intake plenum ( models 078÷150 onl y). KSG – Droplet eliminator made of plastic material. Inserted in the BA module ( models 078÷150 onl y).

Accessories supplied separately KB 2R – Additional water-filled heating coil made of copper pipes and alumini um fins, inserted in the BA modul e (models 015÷051 onl y). KR – Carbon steel el ectrical heater with zinc steel fi ns fitted i n the BA module (for models 015÷051 onl y) completed with control board with magnetothermic switch, 2 safety thermostats, power contactors and user terminal board. KPCC - Blind panel made of pr e-painted steel featuring knockout for duct connec tion. Designed to be fi xed to the PMA intake/deli ver y plenum. KPBM – Delivery panel made of pre-painted steel with rectangular alumini um spigot featuring a double row of adjus table fins . Connect to the PMA delivery plenum. KPBC – Pre-painted steel panel with circular spigots. Designed to be fi xed to the PMA intake/deli ver y plenum (models 015÷051 only). KSER – Conjugated damper made of galvanised s teel for air renewal (25% max.) and air recirculation. Designed to be fi xed to the PMA intake plenum (models 015÷051 onl y. KCMS – Manual control for KSER damper. KQE – Control board in seal ed housing (IP55) with power termi nal boar d to be located inside the SV fan module (models 015-020-029-038 onl y) completed with relay for the use of PRV steam pr oducer.

Standard controls ● KCV2 (supplied loose) Panel with 3-speed switch compl ete with summer/off/winter switch, with possibility to connect the mini mum temper ature thermostat externally.

(Dimensions 145 x 82 x 40 mm)

● KTCV2 (supplied loo se) Control and regulation panel comprising: off/continuous ventilati on/ther mostat-controlled ventilati on switch; ambi ent thermostat; summer/winter switch; speed switch; auxiliary contacts (230 Vac) for controlling ON/OFF val ves in 2-pipe, 2- pipe with heater or 4-pipe systems, with possibility to connect the minimum temperature thermostat externally.

(Dimensions 145 x 82 x 40 mm)

● KTCVA (supplied loose) Electronic contr ol panel comprising: continuous ventilati on/off/ ther mostat-controlled ventilation switch; three-speed switch; ambient thermostat; automatic summer/winter switch; red/green heating/cooling LED; auxiliary contact (230 Vac) for controlling the ON/OFF val ve for 2-pipe systems.

(Dimensions 145 x 82 x 40 mm)

● KTCVR (supplied loose) Electronic contr ol panel comprising: on/off/heater switch; automatic summer/winter switch; automatic speed/mini mum speed switch; comfort adj ustment knob ±5°C; auxiliary contacts (230 Vac) for controlling the ON/OFF val ve for 2-pipe, 2-pipe with heater or 4-pipe systems. Minimum temperature thermostat functi on, de-layering cycle and dirty filter signal.

0

(Dimensions 145 x 82 x 40 mm)

● KSO (supplied loose) Air sensor with remote control option (2m) for KTCV2, KTCVA, KTCVR.

● KTCVM (supplied loose) Control and adj ustment panel comprising: ON/OFF switch, speed switch; room thermostat; outputs (0-10 V DC) for control of variable-openi ng val ves i n 4-pi pe systems.

(Dimensions 145 x 82 x 40 mm)

● KPAU (supplied loose) Panel with humidistat for contr ol of humidifi er, availabl e in units UTNB and UTNA.

%40

50

80

90

100

60

70

(Dimensions 75 x 75 x 25,5 mm)

Page 5: K11142 ed.5 UTNA GB

55

Evolved controls

● KPCM (supplied loose) Electronic contr ol panel with LCD display and 11 keys, for the manual or automatic regulation of all the machine functions on the basis of the chosen ambient temperature. T he panel is designed to be wall-mounted.

Mode

CONT

ON OFF

S C

(Dimensions 70 X 101 X 20 mm)

● KICM (supplied loose) Fitted panel with liquid cr ystal displ ay, designed for installation in fitted wall boxes and thr ee-module plates, for the manual or automatic regulation of all the unit functi ons on the basis of the chosen ambient temperature, in combinati on with the KCMS electr onic car d.

(Dimensions 65,2 x 44,4 x 27,3 mm)

● KCMS (supplied loose) Electronic card, which can be configured as a MASTER or SLAVE card, for the manual or automatic regulati on of all the machi ne functi ons, complete with container for any additi onal KMVR modules.

● KMVR (supplied loose) Module for management of ON/OFF val ves in 2-pipe or 4-pi pe systems and for management of el ectric heater, to be used in conjuncti on with the electronic card KCMS, KCMS/PCM, CMS, CMS/PCM. Includes two auxiliary contacts: summer/winter consensus and boiler control.

● KSTI (supplied loo se) Temperature sensor for additional water heating coil, to be used in combinati on with the KCMS.

Serial interfaces (for ev olv ed controls) ● KISI (supplied loose) CAN-bus (Controller Area N etwor k) serial interface for sys tems , indispensable for networ king the units and serial addresses, for use with the KCMS, KCMS/PCM, CMS, CMS/PCM electronic card (Can-Open pr otocol).

● KRS485 ( supplied loo se) RS485 serial interface for logical dialogue with building automation and supervision systems, for use with the KCMS, KCMS/PCM, CMS, CMS/PCM electronic card (Supported protocols: proprietor protocol; ModBus® RTU).

Serial converters (supplied loose) ● KRS232 ( supplied loo se) RS485/RS232 serial converter for connection to super vision systems, for use with one or more KRS485 serial i nterface systems in the event of centralised unit management.

● KUSB (supplied loose) RS485/USB serial converter for connection to super vision systems, for use with one or more KRS485 serial i nterface systems in the event of centralised unit management.

Note: For further information on command s and controls and for the electrical connection diagrams, refer to the Technical Note code K20002.

Page 6: K11142 ed.5 UTNA GB

66

UTNA technical features

MODEL UTNA 015 020 029 038 051 Technical dat a Rated heating capacity (**) BA 2R KB2R kW 11,3 14,2 20,7 25,8 35,2 Water flow rate (**) BA 2R KB2R L/h 985 1.237 1.806 2.258 3.073 Water pressure drop (**) BA 2R KB2R kPa 4 7 8 10 15 Rated cooling capacity (total heat) (*) BA 4R kW 7,2 8,8 13,9 17,3 21,4 Rated cooling capacity (perceptibl e heat) (*) BA 4R kW 6,2 8,2 11,6 14,7 19,5 Water flow rate (*) BA 4R L/h 1.232 1.508 2.303 2.972 3.674 Water pressure drop (*) BA 4R kPa 6 9 16 22 7 Rated heating capacity (**) BA 4R kW 18,5 24,0 33,7 42,8 57,6 Water flow rate (**) BA 4R L/h 1.614 2.100 2.945 3.740 5.037 Water pressure drops (**) BA 4R kPa 8 13 20 26 10 Heating capacity (50°C inl et water) (***) BA 4R kW 10,5 13,4 19,3 24,6 32,4 Rated cooling capacity (total heat) (*) BA 6R kW 9,9 12,5 17,9 22,4 30,9 Rated cooling capacity (perceptibl e heat) (*) BA 6R kW 7,8 10,4 14,1 18,0 25,2 Water flow rate (*) BA 6R L/h 1.699 2.141 3.076 3.856 5.307 Water pressure drop (*) BA 6R kPa 12 18 12 14 22 Rated heating capacity (**) BA 6R kW (•) (•) (•) (•) (•) Heating capacity (50°C inl et water) (***) BA 6R kW 13,3 17,7 24,0 30,6 42,5 Coil water content BA 2R/4R/6R L 1,1 / 2,2 / 3,3 1,1 / 2,2 / 3,3 1,9 / 3,9 / 5,9 2,3 / 4,5 / 6,8 2,8 / 5,6 / 8,4 Maxi mum allowed pressure water si de kPa 600 600 600 600 600 Fans SV n. 1 1 1 1 1 Rated air flow rate ( ); speed: maxi mum SV m3/h 1.800 2.640 3.220 4.260 6.120 average SV m3/h 1.370 2.240 2.400 3.500 - minimum SV m3/h 1.060 1.480 1.560 2.850 4.390 E.S.P. ( ); speed: maxi mum SV Pa 90 90 90 90 130 sound pr essure speed maxi mum dB(A) 50,9 55,6 54,9 59,8 61,5 average dB(A) 44,3 50,2 48,3 55,7 - minimum dB(A) 37,1 42,1 38,7 51,4 54,4 Reusable filter n.x(axb) n. x mm 2x( 415x290) 2x( 415x290) 2x( 565x355) 2x( 565x410) 2x( 615x460) Electrical data Power suppl y V-ph-Hz 230-1- 50 230-1- 50 230-1- 50 230-1- 50 400-3- 50 Maxi mum power input W 370 700 700 1.250 1.850 Maxi mum current input A 1,7 3,0 3,0 5,4 3,1 Steam humidifier (☼) MUV PRV Maxi mum steam produc tion 230V-1ph-50Hz kg/h 3,0 3,0 5,0 5,0 - 400V-3ph-50Hz 3,0 3,0 5,0 5,0 10,0

Electrical heater (☼) KR Power 230V-1ph-50Hz kW 1,5 3 4,5 6 -

230V-1ph-50Hz kW 3 4,5 6 9 - 230V-1ph-50Hz kW 4,5 6 9 12 - 400V-3ph-50Hz kW 1,5 3 4,5 6 9 400V-3ph-50Hz kW 3 4,5 6 9 12 400V-3ph-50Hz kW 4,5 6 9 12 18

(*) In the followi ng conditions : ambi ent temperature: 27°C DB; 19°C WB. (47% rh); inlet water temperature: 7°C with ∆t : 5°C; maxi mum speed. (**) In the followi ng conditions : ambi ent temperature: 20°C; inlet water temperature: 70°C with ∆t: 10°C; maximum speed. (***) In the following conditions: ambient temperature 20°C; inlet water temperature: 50°C, water fl ow rate as in cooling mode; maxi mum speed.

(•) Do not use with water at 70°C. Performances with different temperatures ar e illustrated i n the perfor mance tables on the followi ng pages. ( ) In the following conditi ons: 4 row coil (BA4R) and filter (G3). Fan performances with different configurations are illustrated on the followi ng pages. (****) The sound pr essure l evel in dB(A) refers to readings taken 3 m from the duct-free air outlet (with a directionality factor equal to 2).

(☼) Other technical features are described on pages 35 and 41.

Page 7: K11142 ed.5 UTNA GB

77

UTNA technical features

MODEL UTNA 078 107 130 150 Technical dat a Rated heating capacity (**) BA 2R KB2R kW 57,5 82,6 92,7 106,0 Water flow rate (**) BA 2R KB2R L/h 5.025 7.223 8.102 9.249 Water pressure drop (**) BA 2R KB2R kPa 10 5 6 7 Rated cooling capacity (total heat) (*) BA 4R kW 41,8 60,6 67,8 77,1 Rated cooling capacity (perceptibl e heat) (*) BA 4R kW 33,7 48,2 55,1 63,0 Water flow rate (*) BA 4R L/h 7.181 10.425 11.656 13.260 Water pressure drop (*) BA 4R kPa 15 12 14 14 Rated heating capacity (**) BA 4R kW 92,9 133,0 152,0 174,0 Water flow rate (**) BA 4R L/h 8.125 11.622 13.312 15.226 Water pressure drops (**) BA 4R kPa 15 11 15 14 Heating capacity (50°C inl et water) (***) BA 4R kW 54,4 77,9 88,9 101,6 Rated cooling capacity (total heat) (*) BA 6R kW 55,6 82,7 94,4 108,0 Rated cooling capacity (perceptibl e heat) (*) BA 6R kW 41,9 60,7 70,4 80,7 Water flow rate (*) BA 6R L/h 9.564 14.222 16.221 18.555 Water pressure drop (*) BA 6R kPa 12 21 27 28 Rated heating capacity (**) BA 6R kW (•) (•) (•) (•) Heating capacity (50°C inl et water) (***) BA 6R kW 67,3 96,7 112,3 128,7 Coil water content BA 2R/4R/6R L 5,1/10,2/15,3 8,0/16,1/24,1 8,0/16,1/24,1 9,0/18,1/27,1 Maxi mum allowed pressure water si de kPa 600 600 600 600 Fans SV n. 1 1 1 2 (+) Rated air flow rate ( ); speed: maxi mum SV m3/h 8.580 11.770 14.300 16.500 minimum SV m3/h (••) (••) (••) (••) Maxi mum E.S.P. ( ) SV Pa 170 160 145 140 Minimum E.S.P. ( ) SV Pa 83 87 49 57 Sound pressure: speed (****) maxi mum dB(A) 59,7 61,7 65,4 61,9 Reusable filter n.x(axb) n. x mm 2x( 760x630) 2x( 970x780) 2x( 970x780) 2x( 970x880) Electrical data Power suppl y V-ph-Hz 400-3- 50 400-3- 50 400-3- 50 400-3- 50 4 pole motor power kW 1,5 1,5 2,2 3,0 4/6 pole motor power (•••) KW 1,5 1,5 2,2 3,0 4/8 pole motor power (•••) KW 1,5 1,5 2,2 3,0 4 pole motor maximum current A 3,6 3,6 5,0 6,5 4/6 pole motor maxi mum current (•••) A 3,6 3,6 5,0 6,9 4/8 pole motor maxi mum current (•••) A 3,8 3,8 5,3 6,4 Steam humidifier (☼) MUV PRV Maxi mum steam produc tion 400V-3ph-50Hz kg/h 15,0 15,0 25,0 25,0

Electrical heater (☼) KR Power 400V-3ph-50Hz kW 12 18 18 24 400V-3ph-50Hz kW 18 24 24 36 400V-3ph-50Hz kW 24 36 36 - (*) In the followi ng conditions : ambi ent temperature: 27°C DB; 19°C WB. (47% rh); inlet water temperature: 7°C with ∆t : 5°C; maxi mum speed. (**) In the followi ng conditions : ambi ent temperature: 20°C; inlet water temperature: 70°C with ∆t: 10°C; maximum speed. (***) In the following conditions: ambient temperature 20°C; inlet water temperature: 50°C, water fl ow rate as in cooling mode; maxi mum speed. (•) Do not use with water at 70°C. Yields with different temperatures are illustrated in the yield tables on the followi ng pages. ( ) In the following conditi ons: 4 row coil (BA4R) and filter (G3). Fan performances with different configurations are illustrated on the followi ng pages.

(****) The sound pr essure l evel in dB(A) refers to readings taken 3 m from the duct-free air outlet (with a directionality factor equal to 2). (••) Variable ratio belt drive. (•••) On request the SV fan module on units 078-107-130-150 can be supplied with a three phase 4/6 or 4/8 pole motor. (+) Paired. (☼) Other technical features are described on pages 35 and 41.

Page 8: K11142 ed.5 UTNA GB

8

UTNA installation solutions

○ UTNA air handling ter minal units are designed to air condition mainl y resi dential or commercial environments. ○ Their exceptional features i nclude: • restricted height; • all-inclusive functions: UTNA units are

authentic air handling centr es; • flexi ble and straightforwar d installation; • a wi de range of accessories for refi ned

air handling; • silent running. ○ The UTNA base unit featur es the BA coil module and the SV fan module. ○ If required, the SV module can be used alone as an extrac tor fan. ○ A vast series of modules and accessories supplied under separate cover make UTNA terminal units immensel y versatile and practical.

PMA BA SV

KPBC

PMA KPCC BA SV

BA SV PMA

PMA

BA SV

PMA

KPBM BA SV PMA

BA SV

(1)

PMA BA SV KSER

(1)

(1)

(1)

Page 9: K11142 ed.5 UTNA GB

9

UTNA installation solutions

BA = Coil module SV = Fan module PMA = Intake/deli ver y plenum SIL = Pl enum with silencer KSER = Conjugated damper KPCC = Blind panel with knockouts KPBM = Panel with rectangular spigot KPBC = Panel with circular spigots MUV = Plenum with humidifi er (1) connect to the duc t

I.1.1 POSSIBILE CONFIGURATIONS

(1) (1)

BA SV SIL SIL

(1)

BA SV SIL

(1)

BA SV SIL MUV

BA SV SIL PMA PMA KPBC KSER

MUV

(1)

KPBM + + ductduct + KPCC + + KPBMduct + KPBC + + KPCC + ductduct + KSER + + KPBC + duct

KPBM + + KSER + ductduct + KPCC + + KPBMduct + KPBC + + KPCC + ductduct + KSER + + KPBC + duct

duct + + KSER + ductKPBM + + KPCC + duct

duct + KPCC + + KPBC + ductduct + KPBC + + KSER + ductduct + KSER + + KPBM

KPBM + + KPBMduct + KPCC + + KPCC + ductduct + KPBC + + KPBC + ductduct + KSER + + KSER + duct

KPBM + + KPBMduct + KPCC + + KPCC + ductduct + KPBC + + KPBC + ductduct + KSER + + KSER + duct

duct + + KPCC + ductKPBM + + KPBC + duct

duct + KPCC + + KSER + ductduct + KPBC + + KPBMduct + KSER + + duct

PMA

PMA+

PMA

+ MUV

+

+

+

+PMA SIL

PMAPMA

++

+

+

+

MUV

SIL

+

SV

BA

PMA

PMA + SIL +

Page 10: K11142 ed.5 UTNA GB

10

UTNA 015 performance Cooling capacity

UTNA 015 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 770 3 5,6 5,5 14,9 83 6,3 5,9 16,2 84 6,8 6,1 16,9 84 7,2 6,3 17,6 84 9,1 6,9 20,3 84 11,2 7,5 23,2 84 5 1232 6 6,6 6,0 14,1 84 7,7 6,5 15,3 84 8,3 6,7 15,9 84 8,8 6,9 16,5 84 11,2 7,6 19,1 84 13,9 8,3 21,8 85 5 2055 16 7,7 6,5 13,3 84 9,0 7,0 14,4 84 9,7 7,2 15,0 84 10,3 7,5 15,5 84 13,2 8,3 17,9 85 16,3 9,1 20,4 85 6 770 3 5,3 5,2 15,4 80 5,9 5,7 16,5 84 6,3 5,9 17,2 84 6,8 6,1 17,8 84 8,7 6,7 20,6 84 10,7 7,3 23,5 84 6 1232 6 6,1 5,8 14,5 84 7,2 6,2 15,7 84 7,7 6,5 16,3 84 8,3 6,7 16,9 84 10,7 7,4 19,5 84 13,3 8,1 22,2 85 6 2055 16 7,1 6,2 13,8 84 8,4 6,7 14,9 84 9,0 7,0 15,4 84 9,7 7,2 16,0 84 12,6 8,1 18,3 84 15,7 8,9 20,8 85 7 770 3 5,1 5,0 15,8 78 5,6 5,5 16,8 82 5,9 5,8 17,3 85 6,3 5,9 18,1 84 8,2 6,6 20,9 84 10,2 7,2 23,7 84 7 1232 6 5,7 5,6 14,8 83 6,6 6,0 16,0 84 7,2 6,2 16,6 84 7,7 6,5 17,2 84 10,1 7,2 19,8 84 12,7 7,9 22,5 84 7 2055 16 6,5 6,0 14,2 84 7,8 6,5 15,3 84 8,4 6,7 15,8 84 9,1 7,0 16,4 84 11,9 7,9 18,7 84 15,0 8,7 21,2 85 8 770 3 4,8 4,7 16,3 76 5,4 5,2 17,3 80 5,6 5,5 17,8 82 5,9 5,8 18,3 85 7,7 6,4 21,2 84 9,7 7,0 24,0 84 8 1232 6 5,3 5,2 15,4 80 6,1 5,8 16,4 84 6,6 6,0 17,0 84 7,2 6,2 17,6 84 9,5 7,0 20,1 84 12,1 7,7 22,8 84 8 2055 16 5,8 5,7 14,6 84 7,1 6,2 15,7 84 7,8 6,5 16,2 84 8,4 6,7 16,8 84 11,2 7,6 19,1 84 14,3 8,4 21,6 85 9 770 3 4,5 4,4 16,8 73 5,1 5,0 17,8 78 5,4 5,3 18,3 80 5,6 5,5 18,8 82 7,2 6,3 21,4 84 9,2 6,9 24,2 84 9 1232 6 5,0 4,9 15,9 78 5,7 5,6 16,8 83 6,0 5,8 17,3 84 6,6 6,0 17,9 84 8,9 6,8 20,5 84 11,5 7,5 23,1 84 9 2055 16 5,5 5,4 15,2 81 6,5 6,0 16,1 84 7,1 6,2 16,7 84 7,8 6,5 17,2 84 10,6 7,4 19,5 84 13,6 8,2 22,0 85

10 770 3 4,2 4,1 17,2 71 4,8 4,7 18,2 75 5,1 5,0 18,7 78 5,4 5,3 19,2 80 6,7 6,1 21,7 84 8,7 6,7 24,5 84 10 1232 6 4,7 4,6 16,4 75 5,3 5,2 17,3 80 5,7 5,6 17,7 83 6,0 5,8 18,3 84 8,4 6,6 20,8 84 10,9 7,4 23,4 84 10 2055 15 5,1 5,0 15,7 78 5,8 5,7 16,5 84 6,4 6,0 17,1 84 7,1 6,2 17,6 84 9,9 7,2 19,9 84 12,9 8,0 22,3 84

UTNA 015 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 1065 5 7,7 7,0 12,7 92 8,9 7,5 13,8 92 9,5 7,7 14,3 92 10,2 7,9 14,9 92 12,9 8,8 17,3 92 15,9 9,5 19,9 93 5 1699 12 9,1 7,6 11,7 92 10,6 8,2 12,6 92 11,4 8,5 13,1 92 12,2 8,7 13,6 92 15,5 9,8 15,7 92 19,2 10,7 18,0 93 5 2835 30 10,4 8,1 10,8 92 12,1 8,8 11,6 92 13,0 9,1 12,0 92 14,0 9,5 12,4 92 17,9 10,7 14,2 93 22,2 11,7 16,2 93 6 1065 5 7,0 6,7 13,1 92 8,3 7,2 14,2 92 8,9 7,5 14,7 92 9,6 7,7 15,3 92 12,3 8,6 17,7 92 15,2 9,3 20,3 93 6 1699 12 8,4 7,3 12,2 92 9,9 7,9 13,1 92 10,6 8,2 13,6 92 11,4 8,4 14,1 92 14,8 9,5 16,2 92 18,4 10,4 18,5 93 6 2835 30 9,6 7,8 11,4 92 11,3 8,5 12,2 92 12,2 8,8 12,6 92 13,1 9,1 13,0 92 17,0 10,3 14,8 93 21,3 11,4 16,7 93 7 1065 5 6,7 6,5 13,4 91 7,6 7,0 14,6 92 8,3 7,2 15,2 92 8,9 7,5 15,7 92 11,6 8,3 18,1 92 14,5 9,1 20,6 92 7 1699 12 7,6 7,0 12,7 92 9,1 7,6 13,6 92 9,9 7,8 14,1 92 10,7 8,1 14,6 92 14,0 9,2 16,7 92 17,6 10,1 18,9 93 7 2835 30 8,7 7,4 11,9 92 10,5 8,1 12,8 92 11,4 8,4 13,2 92 12,3 8,8 13,6 92 16,1 10,0 15,4 93 20,4 11,1 17,3 93 8 1065 5 6,3 6,1 14,0 88 7,0 6,7 15,0 92 7,6 7,0 15,6 92 8,2 7,2 16,1 92 10,9 8,1 18,5 92 13,8 8,9 21,0 92 8 1699 12 6,9 6,7 13,2 92 8,4 7,3 14,1 92 9,1 7,5 14,6 92 9,9 7,8 15,1 92 13,2 8,9 17,2 92 16,8 9,8 19,4 93 8 2835 30 7,9 7,1 12,5 92 9,6 7,8 13,3 92 10,5 8,1 13,7 92 11,4 8,4 14,2 92 15,3 9,6 15,9 92 19,5 10,8 17,8 93 9 1065 5 5,9 5,8 14,6 84 6,7 6,5 15,4 91 6,9 6,7 16,0 92 7,6 7,0 16,5 92 10,2 7,9 18,9 92 13,1 8,7 21,4 92 9 1699 12 6,5 6,3 13,7 89 7,6 7,0 14,6 92 8,3 7,3 15,1 92 9,1 7,5 15,6 92 12,4 8,6 17,6 92 16,0 9,6 19,9 93 9 2835 30 7,0 6,7 13,1 92 8,7 7,4 13,9 92 9,6 7,7 14,3 92 10,5 8,1 14,7 92 14,4 9,3 16,5 92 18,6 10,4 18,4 93

10 1065 5 5,5 5,4 15,3 81 6,3 6,1 16,0 87 6,7 6,5 16,3 90 7,1 6,9 16,7 94 9,5 7,7 19,2 92 12,4 8,5 21,7 92 10 1699 12 6,1 5,9 14,4 86 6,9 6,7 15,0 93 7,6 7,0 15,6 92 8,3 7,3 16,1 92 11,6 8,3 18,1 92 15,2 9,3 20,3 93 10 2835 29 6,5 6,3 13,7 89 7,8 7,1 14,5 92 8,7 7,4 14,9 92 9,6 7,7 15,3 92 13,4 9,0 17,0 92 17,7 10,1 18,9 93

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 1800

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors::

UTNA 015

Air flow m3/h 600 900 1200 1500 1800 2100 Capacity correction factor 0,59 0,74 0,85 0,93 1,00 1,05

Page 11: K11142 ed.5 UTNA GB

11

UTNA 015 performance Heating capacity

UTNA 015 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 485 1 10,6 10,7 9,6 14,5 7,6 21,9 6,6 25,5 5,7 29,1 5,3 30,6 50 650 2 11,5 12,1 10,4 15,7 8,3 22,9 7,2 26,4 6,1 29,9 5,7 31,3 50 985 5 12,7 13,7 11,4 17,2 9,0 24,1 7,9 27,5 6,7 30,8 6,2 32,1 60 485 1 12,7 13,7 11,6 17,5 9,6 25,0 8,6 28,7 7,6 32,3 7,2 33,7 60 650 2 13,8 15,4 12,6 19,1 10,4 26,3 9,3 29,8 8,2 33,3 7,8 34,7 60 985 4 15,1 17,3 13,8 20,8 11,4 27,8 10,2 31,1 9,0 34,5 8,5 35,8 70 485 1 14,7 16,8 13,7 20,6 11,6 28,2 10,6 31,8 9,6 35,5 9,2 36,9 70 650 2 16,0 18,7 14,9 22,4 12,6 29,7 11,5 33,2 10,4 36,8 9,9 38,1 70 985 4 17,5 20,9 16,2 24,5 13,7 31,4 12,5 34,9 11,3 38,2 10,8 39,6

UTNA 015 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 770 2 14,5 16,1 12,8 19,0 9,5 24,6 7,8 27,3 6,2 29,9 5,6 31,0 40 1232 6 16,3 18,8 14,4 21,3 10,6 26,3 8,8 28,7 7,0 31,1 6,2 32,0 40 2055 14 17,8 20,9 15,6 23,2 11,5 27,7 9,5 29,9 7,5 32,0 6,8 32,8 45 770 2 16,2 18,6 14,5 21,5 11,1 27,1 9,4 29,8 7,8 32,4 7,2 33,5 45 1232 6 18,2 21,5 16,2 24,1 12,4 29,1 10,6 31,5 8,7 33,9 8,0 34,8 45 2055 14 19,8 23,9 17,7 26,2 13,5 30,7 11,4 32,9 9,4 35,0 8,7 35,9 50 770 2 17,9 21,1 16,1 24,0 12,7 29,6 11,1 32,3 9,4 35,0 8,8 36,0 50 1232 5 20,1 24,3 18,1 26,9 14,2 31,9 12,3 34,3 10,5 36,7 9,8 37,6 50 2055 14 21,8 26,9 19,7 29,2 15,4 33,8 13,4 35,9 11,4 38,1 10,6 38,9 60 790 2 21,4 26,3 19,7 29,2 16,1 34,8 14,4 37,6 12,7 40,3 12,1 41,3 60 1060 4 23,1 28,7 21,2 31,4 17,4 36,7 15,5 39,2 13,7 41,7 12,9 42,7 60 1614 9 25,1 31,5 22,9 34,0 18,7 38,8 16,7 41,2 14,7 43,4 13,9 44,3 70 790 2 24,9 31,3 23,1 34,3 19,5 40,0 17,7 42,8 16,0 45,5 15,3 46,5 70 1060 4 26,8 34,1 24,8 36,9 20,9 42,2 19,0 44,8 17,2 47,3 16,4 48,3 70 1614 8 29,0 37,4 26,9 39,9 22,6 44,8 20,5 47,1 18,5 49,4 17,7 50,3

UTNA 015 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Q Tau Q Tau QT Tau °C l/h kPa kW °C kW °C kW °C kW °C kW °C kW °C 40 1065 4 19,0 22,4 16,7 24,6 12,3 28,8 10,2 30,8 8,1 32,7 7,2 33,5 40 1699 10 20,9 25,2 18,4 27,1 13,5 30,6 11,1 32,3 8,8 33,9 7,9 34,6 40 2835 26 22,5 27,4 19,7 29,0 14,5 32,0 11,9 33,5 9,4 34,8 8,4 35,4 45 1065 4 21,2 25,6 18,9 27,8 14,4 32,0 12,2 34,0 10,1 35,9 9,3 36,7 45 1699 10 23,3 28,7 20,8 30,5 15,8 34,1 13,4 35,8 11,1 37,4 10,1 38,1 45 2835 26 25,0 31,1 22,2 32,7 16,9 35,8 14,3 37,2 11,8 38,6 10,8 39,1 50 1065 4 23,4 28,7 21,0 30,9 16,5 35,2 14,3 37,2 12,2 39,2 11,3 39,9 50 1699 10 25,7 32,1 23,1 34,0 18,1 37,6 15,7 39,3 13,3 41,0 12,4 41,6 50 2835 25 27,6 34,8 24,8 36,4 19,4 39,5 16,7 40,9 14,2 42,4 13,2 42,9 60 985 4 27,2 34,3 24,9 36,6 20,4 41,0 18,2 43,1 16,0 45,2 15,1 46,0 60 1310 6 29,1 37,0 26,6 39,1 21,7 43,1 19,3 45,0 17,0 46,8 16,1 47,6 60 2003 13 31,3 40,2 28,6 42,0 23,3 45,5 20,7 47,1 18,2 48,7 17,2 49,4 70 985 4 31,5 40,5 29,2 42,9 24,5 47,4 22,3 49,5 20,1 51,6 19,2 52,5 70 1310 6 33,7 43,7 31,1 45,8 26,1 49,8 23,7 51,8 21,4 53,7 20,4 54,4 70 2003 13 36,3 47,4 33,5 49,2 28,0 52,7 25,4 54,4 22,9 56,0 21,9 56,7

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 1800

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit

Page 12: K11142 ed.5 UTNA GB

12

UTNA 020 performance Cooling capacity

UTNA 020 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 940 4 7,1 7,0 16,1 77 7,8 7,7 17,2 80 8,2 8,0 18,0 81 8,8 8,2 18,7 81 11,1 9,0 21,6 81 13,6 9,7 24,7 81 5 1508 9 8,1 7,9 15,2 81 9,4 8,4 16,5 81 10,1 8,7 17,1 81 10,8 8,9 17,8 81 13,7 9,9 20,6 81 16,9 10,7 23,5 81 5 2515 24 9,5 8,4 14,5 81 11,1 9,1 15,7 81 11,9 9,4 16,3 81 12,7 9,7 17,0 81 16,2 10,8 19,6 81 20,0 11,7 22,3 82 6 940 4 6,8 6,6 16,5 75 7,5 7,4 17,6 78 7,9 7,7 18,2 80 8,2 8,0 18,9 81 10,5 8,8 21,8 81 13,0 9,5 24,9 81 6 1508 9 7,7 7,5 15,5 80 8,8 8,1 16,8 81 9,4 8,4 17,4 81 10,1 8,7 18,1 81 13,0 9,6 20,9 81 16,2 10,5 23,8 81 6 2515 23 8,8 8,1 14,8 81 10,3 8,8 16,1 81 11,1 9,1 16,7 81 12,0 9,4 17,3 81 15,4 10,5 19,9 81 19,2 11,4 22,6 81 7 940 4 6,4 6,3 16,9 73 7,1 7,0 18,0 76 7,5 7,4 18,6 78 7,9 7,7 19,2 80 9,9 8,6 22,0 81 12,4 9,4 25,1 81 7 1508 9 7,2 7,1 16,0 77 8,1 7,9 17,1 81 8,8 8,2 17,7 81 9,4 8,4 18,4 81 12,3 9,4 21,1 81 15,4 10,3 24,0 81 7 2515 23 8,0 7,8 15,2 81 9,5 8,4 16,4 81 10,3 8,8 17,0 81 11,2 9,1 17,7 81 14,6 10,2 20,2 81 18,3 11,2 22,9 81 8 940 4 6,0 5,9 17,3 71 6,8 6,7 18,5 74 7,1 7,0 19,0 76 7,5 7,4 19,6 78 9,4 8,4 22,3 81 11,8 9,2 25,3 81 8 1508 9 6,8 6,7 16,4 75 7,7 7,5 17,5 79 8,1 7,9 18,0 81 8,8 8,2 18,7 81 11,6 9,2 21,4 81 14,7 10,0 24,3 81 8 2515 23 7,5 7,4 15,7 79 8,8 8,1 16,8 81 9,5 8,5 17,4 81 10,4 8,8 18,0 81 13,8 9,9 20,6 81 17,5 10,9 23,3 81 9 940 4 5,7 5,6 17,7 69 6,4 6,3 18,9 73 6,8 6,7 19,4 74 7,1 7,0 20,0 76 8,8 8,2 22,5 81 11,2 9,0 25,5 81 9 1508 9 6,4 6,3 16,9 73 7,2 7,1 17,9 77 7,7 7,5 18,4 79 8,1 7,9 19,0 81 10,9 8,9 21,7 81 14,0 9,8 24,5 81 9 2515 23 7,0 6,9 16,2 76 8,0 7,8 17,1 81 8,7 8,1 17,7 81 9,5 8,5 18,4 81 13,0 9,6 20,9 81 16,7 10,6 23,6 81

10 940 4 5,3 5,2 18,1 67 6,0 5,9 19,3 71 6,4 6,3 19,8 72 6,8 6,7 20,4 74 8,3 8,1 22,6 82 10,6 8,8 25,7 81 10 1508 9 6,0 5,9 17,4 71 6,8 6,7 18,4 75 7,3 7,1 18,9 77 7,7 7,5 19,4 79 10,2 8,7 22,0 81 13,2 9,6 24,8 81 10 2515 23 6,6 6,5 16,7 74 7,5 7,4 17,6 78 8,0 7,8 18,1 81 8,7 8,2 18,7 81 12,1 9,3 21,2 81 15,8 10,4 23,9 81

UTNA 020 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 1345 8 9,6 9,3 13,6 89 11,2 9,9 14,8 89 12,0 10,2 15,4 89 12,8 10,5 16,1 89 16,2 11,6 18,7 90 19,9 12,5 21,4 90 5 2141 18 11,6 10,0 12,7 89 13,4 10,8 13,8 89 14,4 11,1 14,4 89 15,4 11,5 14,9 90 19,6 12,8 17,3 90 24,2 13,9 19,8 90 5 3585 46 13,3 10,8 11,9 89 15,5 11,6 12,9 89 16,6 12,0 13,4 90 17,8 12,4 13,9 90 22,7 13,9 16,0 90 28,1 15,2 18,2 91 6 1345 8 9,2 9,0 13,9 88 10,4 9,6 15,2 89 11,2 9,9 15,8 89 12,0 10,2 16,4 89 15,4 11,3 19,0 90 19,1 12,3 21,7 90 6 2141 18 10,6 9,6 13,2 89 12,5 10,4 14,3 89 13,5 10,8 14,8 89 14,5 11,1 15,4 89 18,6 12,4 17,7 90 23,2 13,6 20,2 90 6 3585 46 12,2 10,3 12,4 89 14,4 11,2 13,4 89 15,6 11,6 13,9 89 16,7 12,0 14,4 90 21,6 13,5 16,5 90 27,0 14,9 18,7 90 7 1345 8 8,7 8,5 14,5 85 9,8 9,4 15,3 91 10,4 9,6 16,1 89 11,2 9,9 16,8 89 14,5 11,0 19,3 90 18,2 12,0 22,0 90 7 2141 18 9,7 9,3 13,6 89 11,5 10,0 14,7 89 12,5 10,4 15,2 89 13,5 10,7 15,8 89 17,6 12,1 18,1 90 22,2 13,2 20,6 90 7 3585 46 11,2 9,9 12,9 89 13,3 10,7 13,9 89 14,5 11,2 14,4 89 15,6 11,6 14,9 89 20,5 13,1 16,9 90 25,9 14,5 19,2 90 8 1345 8 8,2 8,0 15,0 82 9,3 9,0 15,9 88 9,8 9,4 16,3 90 10,3 9,6 17,1 89 13,7 10,7 19,6 90 17,3 11,7 22,3 90 8 2141 18 9,1 8,8 14,1 87 10,6 9,7 15,1 89 11,5 10,0 15,6 89 12,5 10,4 16,2 89 16,6 11,7 18,5 90 21,1 12,9 21,0 90 8 3585 45 10,1 9,4 13,4 89 12,2 10,3 14,4 89 13,4 10,7 14,9 89 14,5 11,1 15,3 90 19,4 12,7 17,4 90 24,7 14,1 19,6 90 9 1345 8 7,7 7,5 15,6 79 8,8 8,5 16,4 85 9,3 9,0 16,8 87 9,8 9,4 17,3 90 12,8 10,5 19,9 90 16,4 11,5 22,6 90 9 2141 18 8,6 8,3 14,7 84 9,7 9,4 15,4 90 10,5 9,7 16,1 89 11,5 10,0 16,6 89 15,6 11,4 18,9 90 20,1 12,6 21,3 90 9 3585 45 9,3 9,0 13,9 88 11,1 9,9 14,9 89 12,2 10,3 15,3 89 13,4 10,7 15,8 89 18,2 12,3 17,9 90 23,5 13,7 20,1 90

10 1345 8 7,2 7,0 16,1 76 8,2 8,0 17,0 82 8,8 8,5 17,4 84 9,3 9,0 17,8 87 12,0 10,2 20,3 90 15,5 11,2 22,9 90 10 2141 18 8,0 7,8 15,3 81 9,1 8,8 16,0 87 9,7 9,4 16,4 90 10,5 9,7 17,0 90 14,6 11,0 19,3 90 19,0 12,3 21,7 90 10 3585 45 8,6 8,4 14,6 84 10,0 9,4 15,4 89 11,1 9,9 15,8 89 12,2 10,3 16,3 89 17,0 11,9 18,3 90 22,3 13,3 20,5 90

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 2640

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 020

Air flow m3/h 1200 1500 1800 2100 2400 2640 2700 2920 Capacity correction factor 0,73 0,81 0,87 0,93 0,97 1,00 1,01 1,03

Page 13: K11142 ed.5 UTNA GB

13

UTNA 020 performance Heating capacity

UTNA 020 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 610 2 13,3 8,4 12,0 12,4 9,5 20,2 8,3 24,0 7,1 27,8 6,6 29,3 50 815 3 14,4 9,6 13,1 13,4 10,4 21,0 9,0 24,8 7,7 28,5 7,2 29,9 50 1237 7 15,9 11,0 14,4 14,8 11,4 22,1 9,9 25,7 8,4 29,3 7,8 30,7 60 610 2 15,9 11,0 14,6 15,0 12,0 22,8 10,8 26,7 9,6 30,5 9,1 32,0 60 815 3 17,2 12,4 15,8 16,3 13,1 23,9 11,7 27,7 10,4 31,4 9,8 32,9 60 1237 7 18,9 14,1 17,4 17,8 14,3 25,2 12,8 28,9 11,3 32,4 10,7 33,9 70 610 2 18,5 13,6 17,1 17,6 14,6 25,5 13,3 29,4 12,0 33,3 11,5 34,8 70 815 3 20,0 15,2 18,6 19,1 15,8 26,8 14,4 30,6 13,0 34,3 12,5 35,8 70 1237 7 22,0 17,2 20,4 20,9 17,3 28,4 15,7 32,0 14,2 35,7 13,6 37,1

UTNA 020 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 940 3 18,3 13,3 16,1 16,5 12,0 22,7 9,9 25,7 7,9 28,6 7,1 29,8 40 1508 8 20,7 15,8 18,3 18,7 13,5 24,3 11,2 27,0 8,9 29,7 8,0 30,8 40 2515 20 22,7 17,8 20,1 20,5 14,8 25,6 12,2 28,1 9,7 30,6 8,7 31,6 45 940 3 20,4 15,4 18,3 18,6 14,0 24,8 12,0 27,9 9,9 30,8 9,1 32,0 45 1508 8 23,1 18,2 20,7 21,1 15,8 26,7 13,5 29,5 11,2 32,2 10,2 33,3 45 2515 20 25,4 20,4 22,6 23,1 17,3 28,3 14,7 30,8 12,2 33,3 11,1 34,3 50 940 3 22,6 17,6 20,4 20,8 16,1 27,0 14,0 30,1 11,9 33,1 11,1 34,2 50 1508 8 25,5 20,6 23,0 23,5 18,2 29,2 15,8 32,0 13,4 34,7 12,5 35,8 50 2515 20 28,0 23,0 25,2 25,7 19,8 31,0 17,2 33,5 14,6 36,0 13,6 37,0 60 1030 4 27,6 22,7 25,3 25,9 20,8 32,0 18,6 35,0 16,5 38,0 15,6 39,2 60 1375 6 29,8 24,8 27,3 27,8 22,4 33,7 20,0 36,5 17,7 39,3 16,7 40,4 60 2100 14 32,4 27,4 29,6 30,2 24,3 35,7 21,7 38,3 19,1 40,9 18,1 41,9 70 1030 4 32,1 27,1 29,7 30,4 25,2 36,6 22,9 39,6 20,7 42,6 19,8 43,8 70 1375 6 34,6 29,6 32,0 32,7 27,0 38,6 24,6 41,5 22,2 44,3 21,3 45,4 70 2100 13 37,5 32,6 34,7 35,4 29,3 41,0 26,6 43,6 24,0 46,2 23,0 47,3

UTNA 020 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 1345 7 24,8 19,6 21,9 22,1 16,2 26,9 13,4 29,2 10,6 31,5 9,5 32,3 40 2141 16 27,6 22,3 24,3 24,5 17,9 28,7 14,8 30,7 11,7 32,6 10,5 33,4 40 3585 40 29,8 24,5 26,2 26,4 19,3 30,1 15,9 31,9 12,6 33,6 11,3 34,2 45 1345 7 27,7 22,4 24,7 24,9 18,9 29,8 16,1 32,1 13,3 34,4 12,2 35,3 45 2141 15 30,8 25,4 27,4 27,6 20,9 31,8 17,8 33,9 14,7 35,8 13,4 36,6 45 3585 39 33,2 27,8 29,6 29,8 22,5 33,5 19,1 35,3 15,8 37,0 14,4 37,7 50 1345 7 30,6 25,3 27,6 27,8 21,7 32,7 18,9 35,0 16,0 37,3 14,9 38,2 50 2141 15 33,9 28,5 30,6 30,8 24,0 35,0 20,8 37,1 17,7 39,0 16,4 39,8 50 3585 38 36,6 31,2 32,9 33,2 25,8 36,9 22,3 38,7 18,9 40,4 17,6 41,1 60 1320 6 36,2 30,8 33,1 33,4 27,2 38,3 24,3 40,7 21,4 43,1 20,2 44,0 60 1760 10 38,8 33,3 35,5 35,7 29,0 40,3 25,9 42,5 22,8 44,6 21,6 45,4 60 2682 22 41,8 36,3 38,2 38,5 31,2 42,5 27,8 44,5 24,5 46,4 23,2 47,1 70 1320 6 42,0 36,5 38,8 39,1 32,7 44,2 29,8 46,6 26,8 49,0 25,7 49,9 70 1760 10 44,9 39,4 41,6 41,8 35,0 46,5 31,8 48,7 28,6 50,9 27,4 51,7 70 2682 21 48,4 42,9 44,7 45,1 37,6 49,2 34,1 51,2 30,7 53,1 29,4 53,9

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 2640

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit.

Page 14: K11142 ed.5 UTNA GB

14

UTNA 029 performance Cooling capacity

UTNA 029 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 1495 7 10,9 10,4 14,5 84 12,6 11,1 15,8 84 13,5 11,5 16,4 84 14,4 11,8 17,1 84 18,3 13,0 19,8 84 22,4 14,1 22,6 85 5 2303 16 12,9 11,2 13,8 84 15,0 12,0 15,0 84 16,0 12,4 15,5 84 17,2 12,8 16,2 84 21,8 14,3 18,7 85 26,9 15,5 21,3 85 5 3985 44 14,9 12,1 13,0 84 17,4 13,0 14,0 84 18,7 13,5 14,6 84 20,0 13,9 15,1 84 25,5 15,6 17,4 85 31,6 17,1 19,8 85 6 1495 7 10,3 10,0 14,8 83 11,7 10,8 16,1 84 12,6 11,1 16,8 84 13,5 11,5 17,4 84 17,4 12,7 20,1 84 21,5 13,8 22,9 85 6 2303 16 11,8 10,8 14,2 84 13,9 11,6 15,3 84 15,0 12,0 15,9 84 16,1 12,4 16,5 84 20,7 13,9 19,0 84 25,8 15,2 21,6 85 6 3985 44 13,7 11,6 13,5 84 16,2 12,5 14,5 84 17,5 13,0 15,0 84 18,8 13,5 15,6 84 24,3 15,2 17,8 85 30,3 16,7 20,2 85 7 1495 7 9,8 9,5 15,3 81 10,8 10,4 16,4 84 11,7 10,8 17,1 84 12,6 11,1 17,7 84 16,4 12,4 20,4 84 20,5 13,5 23,2 84 7 2303 16 10,8 10,3 14,6 84 12,8 11,2 15,7 84 13,9 11,6 16,3 84 15,0 12,0 16,9 84 19,6 13,5 19,4 84 24,7 14,8 22,0 85 7 3985 44 12,5 11,1 13,9 84 15,0 12,0 15,0 84 16,2 12,5 15,5 84 17,5 13,0 16,0 84 23,0 14,7 18,2 85 29,1 16,2 20,6 85 8 1495 7 9,2 9,0 15,8 78 10,3 10,1 16,8 83 10,8 10,4 17,4 84 11,7 10,8 18,0 84 15,4 12,1 20,7 84 19,5 13,2 23,5 84 8 2303 16 10,1 9,8 15,0 82 11,8 10,8 16,1 84 12,8 11,2 16,7 84 13,9 11,6 17,3 84 18,5 13,1 19,7 84 23,5 14,4 22,3 85 8 3985 44 11,3 10,6 14,4 84 13,7 11,5 15,4 84 15,0 12,0 15,9 84 16,3 12,5 16,5 84 21,8 14,2 18,7 84 27,7 15,8 21,0 85 9 1495 7 8,7 8,4 16,3 76 9,8 9,5 17,3 80 10,3 10,1 17,7 83 10,9 10,6 18,2 85 14,5 11,8 21,0 84 18,5 12,9 23,8 84 9 2303 16 9,5 9,2 15,6 79 10,7 10,4 16,4 85 11,7 10,8 17,1 84 12,8 11,2 17,7 84 17,4 12,7 20,1 84 22,4 14,1 22,7 85 9 3985 43 10,3 10,0 14,9 83 12,5 11,1 15,8 84 13,7 11,5 16,4 84 15,0 12,0 16,9 84 20,5 13,8 19,1 84 26,4 15,4 21,5 85

10 1495 7 8,1 7,9 16,8 73 9,2 9,0 17,8 78 9,8 9,5 18,2 80 10,3 10,1 18,7 82 13,5 11,5 21,3 84 17,5 12,6 24,0 84 10 2303 16 8,9 8,6 16,1 77 10,1 9,8 17,0 82 10,7 10,4 17,4 84 11,7 10,8 18,0 84 16,2 12,3 20,5 84 21,2 13,7 23,0 85 10 3985 43 9,6 9,4 15,5 80 11,2 10,6 16,3 84 12,4 11,1 16,8 84 13,7 11,5 17,3 84 19,1 13,3 19,5 84 25,1 14,9 21,9 85

UTNA 029 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 1925 5 13,9 12,5 12,6 92 16,1 13,5 13,7 92 17,3 13,9 14,2 92 18,5 14,3 14,8 92 23,4 15,9 17,2 92 28,8 17,2 19,8 93 5 3076 12 16,5 13,6 11,6 92 19,2 14,7 12,5 92 20,6 15,2 13,0 92 22,0 15,7 13,5 92 28,1 17,6 15,6 93 34,8 19,2 17,9 93 5 5130 30 18,8 14,6 10,7 92 21,9 15,8 11,5 92 23,5 16,4 11,9 92 25,2 17,0 12,3 92 32,3 19,2 14,1 93 40,1 21,1 16,0 93 6 1925 5 12,7 12,1 13,0 92 15,0 13,0 14,1 92 16,1 13,4 14,7 92 17,3 13,9 15,2 92 22,2 15,4 17,6 92 27,6 16,8 20,1 93 6 3076 12 15,1 13,1 12,1 92 17,9 14,1 13,1 92 19,2 14,7 13,5 92 20,7 15,2 14,0 92 26,7 17,0 16,1 93 33,4 18,7 18,3 93 6 5130 30 17,3 14,0 11,3 92 20,4 15,2 12,1 92 22,0 15,8 12,5 92 23,7 16,4 12,9 92 30,7 18,6 14,7 93 38,5 20,5 16,6 93 7 1925 5 12,0 11,7 13,3 92 13,8 12,5 14,5 92 14,9 13,0 15,1 92 16,1 13,4 15,6 92 21,0 15,0 18,0 92 26,3 16,4 20,5 93 7 3076 12 13,8 12,5 12,6 92 16,5 13,6 13,6 92 17,9 14,1 14,0 92 19,3 14,6 14,5 92 25,3 16,5 16,6 93 31,9 18,2 18,8 93 7 5130 30 15,8 13,3 11,9 92 18,9 14,6 12,7 92 20,5 15,2 13,1 92 22,1 15,7 13,5 92 29,1 17,9 15,2 93 36,9 19,9 17,2 93 8 1925 5 11,4 11,1 13,9 88 12,6 12,1 14,9 92 13,8 12,5 15,5 92 14,9 13,0 16,0 92 19,8 14,6 18,4 92 25,1 16,0 20,9 93 8 3076 12 12,4 12,0 13,1 92 15,1 13,0 14,1 92 16,5 13,6 14,5 92 17,9 14,1 15,0 92 23,9 16,0 17,1 92 30,4 17,7 19,3 93 8 5130 30 14,2 12,7 12,5 92 17,3 13,9 13,2 92 18,9 14,5 13,7 92 20,6 15,1 14,1 92 27,5 17,3 15,8 93 35,2 19,4 17,7 93 9 1925 5 10,7 10,4 14,6 85 12,0 11,7 15,3 91 12,6 12,1 15,9 92 13,7 12,5 16,4 92 18,5 14,2 18,8 92 23,8 15,6 21,3 93 9 3076 12 11,7 11,4 13,6 90 13,7 12,5 14,6 92 15,1 13,0 15,0 92 16,5 13,6 15,5 92 22,4 15,5 17,5 92 29,0 17,2 19,7 93 9 5130 30 12,7 12,1 13,0 92 15,7 13,3 13,8 92 17,3 13,9 14,2 92 19,0 14,5 14,6 92 25,9 16,7 16,4 92 33,6 18,8 18,3 93

10 1925 5 10,0 9,7 15,2 81 11,3 11,0 15,9 88 12,0 11,7 16,2 91 12,5 12,1 16,8 92 17,3 13,8 19,2 92 22,5 15,2 21,6 92 10 3076 12 10,9 10,6 14,3 86 12,3 12,0 15,0 92 13,7 12,5 15,5 92 15,1 13,0 16,0 92 21,0 15,0 18,0 92 27,4 16,7 20,2 93 10 5130 30 11,7 11,4 13,6 90 14,1 12,7 14,4 92 15,7 13,3 14,8 92 17,4 13,9 15,2 92 24,3 16,1 16,9 92 31,9 18,2 18,8 93

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 3220

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 029

Air flow m3/h 1200 1500 1800 2100 2400 2700 3000 3220 3300 Capacity correction factor 0,60 0,69 0,76 0,82 0,88 0,92 0,96 1,00 1,00

Page 15: K11142 ed.5 UTNA GB

15

UTNA 029 prestazioni Resa termica

UTNA 029 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 890 3 19,7 11,3 17,8 15,1 14,1 22,4 12,3 25,9 10,5 29,5 9,8 30,9 50 1190 4 21,3 12,7 19,3 16,3 15,2 23,3 13,3 26,8 11,3 30,2 10,5 31,6 50 1806 9 23,2 14,3 21,0 17,7 16,6 24,5 14,4 27,8 12,3 31,1 11,4 32,4 60 890 2 23,5 14,5 21,6 18,2 17,8 25,6 15,9 29,2 14,1 32,7 13,4 34,2 60 1190 4 25,4 16,1 23,3 19,7 19,2 26,8 17,2 30,3 15,2 33,7 14,4 35,1 60 1806 9 27,6 17,9 25,3 21,4 20,8 28,2 18,6 31,6 16,4 34,9 15,6 36,2 70 890 2 27,3 17,6 25,4 21,4 21,5 28,8 19,6 32,4 17,7 36,0 17,0 37,5 70 1190 4 29,5 19,4 27,4 23,1 23,2 30,3 21,1 33,8 19,1 37,3 18,3 38,6 70 1806 8 32,1 21,6 29,7 25,1 25,1 32,0 22,9 35,4 20,7 38,7 19,8 40,0

UTNA 029 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 1495 7 27,3 17,3 24,1 20,0 17,8 25,3 14,7 27,9 11,7 30,4 10,5 31,4 40 2303 14 30,1 19,6 26,5 22,0 19,6 26,8 16,2 29,1 12,8 31,4 11,5 32,3 40 3985 38 32,7 21,7 28,8 23,9 21,2 28,2 17,5 30,3 13,8 32,3 12,4 33,1 45 1495 6 30,5 19,9 27,2 22,6 20,9 28,0 17,7 30,5 14,7 33,1 13,5 34,1 45 2303 14 33,6 22,4 29,9 24,9 22,9 29,7 19,4 32,0 16,1 34,3 14,7 35,2 45 3985 37 36,4 24,7 32,4 26,9 24,7 31,3 21,0 33,4 17,3 35,4 15,9 36,2 50 1495 6 33,6 22,4 30,4 25,2 23,9 30,6 20,8 33,2 17,7 35,7 16,4 36,7 50 2303 14 37,0 25,2 33,4 27,7 26,2 32,6 22,7 34,9 19,3 37,2 18,0 38,1 50 3985 37 40,1 27,7 36,1 30,0 28,3 34,4 24,5 36,5 20,8 38,5 19,4 39,4 60 1450 6 39,7 27,4 36,3 30,2 29,8 35,7 26,6 38,3 23,5 40,9 22,3 41,9 60 1930 10 42,5 29,6 38,9 32,3 31,8 37,4 28,4 39,9 25,0 42,3 23,7 43,2 60 2945 21 45,8 32,3 41,9 34,8 34,2 39,5 30,5 41,7 26,9 43,9 25,4 44,8 70 1450 6 46,0 32,5 42,6 35,4 35,9 40,9 32,7 43,6 29,5 46,2 28,2 47,3 70 1930 9 49,2 35,1 45,5 37,8 38,4 43,0 34,9 45,5 31,4 48,0 30,1 48,9 70 2945 20 53,0 38,3 49,0 40,7 41,2 45,5 37,4 47,8 33,7 50,0 32,2 50,9

UTNA 029 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 1925 4 34,3 22,6 30,2 24,8 22,3 28,9 18,4 30,9 14,6 32,8 13,1 33,6 40 3076 10 37,8 25,4 33,2 27,3 24,4 30,7 20,1 32,4 15,9 34,0 14,3 34,6 40 5130 26 40,5 27,6 35,6 29,2 26,1 32,1 21,5 33,6 17,0 34,9 15,2 35,5 45 1925 4 38,3 25,8 34,1 28,0 26,0 32,1 22,1 34,1 18,3 36,0 16,7 36,8 45 3076 10 42,1 28,9 37,5 30,7 28,5 34,2 24,2 35,9 20,0 37,5 18,3 38,2 45 5130 26 45,1 31,3 40,1 32,9 30,5 35,9 25,8 37,3 21,3 38,7 19,5 39,2 50 1925 4 42,2 29,0 38,0 31,2 29,8 35,4 25,9 37,4 22,0 39,3 20,4 40,1 50 3076 10 46,4 32,4 41,8 34,2 32,7 37,8 28,3 39,5 24,0 41,1 22,3 41,7 50 5130 25 49,7 35,0 44,7 36,6 34,9 39,6 30,2 41,1 25,6 42,5 23,8 43,0 60 1770 4 49,1 34,5 44,9 36,8 36,7 41,2 32,8 43,3 28,9 45,4 27,3 46,2 60 2360 6 52,5 37,3 47,9 39,3 39,2 43,3 34,9 45,1 30,7 47,0 29,1 47,7 60 3598 13 56,4 40,4 51,5 42,2 42,0 45,7 37,4 47,3 32,9 48,9 31,1 49,5 70 1770 4 56,9 40,8 52,6 43,1 44,3 47,6 40,2 49,7 36,2 51,8 34,6 52,6 70 2360 6 60,8 43,9 56,2 46,0 47,2 50,1 42,8 52,0 38,5 53,8 36,8 54,6 70 3598 13 65,3 47,6 60,3 49,4 50,5 52,9 45,8 54,6 41,2 56,2 39,4 56,8

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 3220

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit

Page 16: K11142 ed.5 UTNA GB

16

UTNA 038 performance Cooling capacity

UTNA 038 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 1860 9 13,6 13,3 14,8 83 15,5 14,0 16,2 83 16,6 14,4 16,9 83 17,7 14,9 17,5 83 22,4 16,4 20,3 83 27,5 17,7 23,2 83 5 2972 22 16,0 14,2 14,1 83 18,6 15,2 15,3 83 20,0 15,7 15,9 83 21,3 16,2 16,6 83 27,1 18,0 19,1 83 33,4 19,6 21,8 84 5 4600 49 18,1 15,1 13,5 83 21,0 16,2 14,6 83 22,6 16,8 15,2 83 24,1 17,3 15,8 83 30,8 19,4 18,2 84 38,1 21,2 20,7 84 6 1860 9 12,9 12,6 15,2 81 14,4 13,6 16,5 83 15,5 14,0 17,2 83 16,6 14,4 17,8 83 21,3 16,0 20,6 83 26,3 17,4 23,5 83 6 2972 22 14,7 13,7 14,5 83 17,3 14,7 15,7 83 18,6 15,2 16,3 83 20,0 15,7 16,9 83 25,8 17,6 19,5 83 32,0 19,2 22,2 84 6 4600 48 16,6 14,5 13,9 83 19,6 15,6 15,1 83 21,1 16,2 15,6 83 22,7 16,8 16,2 83 29,3 18,8 18,6 83 36,5 20,7 21,1 84 7 1860 9 12,2 11,9 15,7 79 13,6 13,3 16,7 83 14,3 13,6 17,5 83 15,5 14,0 18,1 83 20,1 15,6 20,9 83 25,1 17,0 23,7 83 7 2972 22 13,5 13,2 14,8 83 16,0 14,2 16,1 83 17,3 14,7 16,7 83 18,7 15,2 17,3 83 24,4 17,1 19,8 83 30,6 18,7 22,5 83 7 4600 48 15,1 13,8 14,4 83 18,1 15,0 15,5 83 19,6 15,6 16,0 83 21,2 16,2 16,6 83 27,8 18,3 19,0 83 35,0 20,1 21,5 84 8 1860 9 11,5 11,2 16,2 76 12,9 12,6 17,2 81 13,6 13,3 17,7 83 14,3 13,6 18,4 83 18,9 15,2 21,1 83 23,9 16,6 24,0 83 8 2972 22 12,7 12,4 15,4 80 14,6 13,7 16,4 83 16,3 14,3 16,9 83 17,3 14,7 17,6 83 23,0 16,6 20,2 83 29,2 18,2 22,8 83 8 4600 48 13,7 13,2 14,8 83 16,6 14,4 15,9 83 18,1 15,0 16,5 83 19,7 15,6 17,0 83 26,2 17,7 19,4 83 33,4 19,6 21,9 84 9 1860 9 10,8 10,5 16,7 74 12,2 11,9 17,7 78 12,9 12,6 18,2 80 13,6 13,3 18,6 83 17,7 14,8 21,4 83 22,7 16,3 24,2 83 9 2972 22 11,9 11,7 15,9 78 13,5 13,2 16,8 83 14,6 13,7 17,4 83 15,9 14,2 18,0 83 21,6 16,1 20,5 83 27,8 17,8 23,1 83 9 4600 48 12,8 12,5 15,3 81 15,1 13,8 16,3 83 16,6 14,4 16,9 83 18,1 15,0 17,4 83 24,6 17,2 19,8 83 31,8 19,1 22,2 84

10 1860 9 10,1 9,8 17,2 72 11,5 11,2 18,1 76 12,2 11,9 18,6 78 12,9 12,6 19,1 80 16,5 14,5 21,7 83 21,4 15,9 24,5 83 10 2972 22 11,1 10,9 16,4 75 12,7 12,4 17,3 80 13,5 13,2 17,7 83 14,5 13,7 18,3 83 20,2 15,6 20,8 83 26,3 17,4 23,5 83 10 4600 48 11,9 11,7 15,9 78 13,6 13,3 16,7 83 15,0 13,8 17,3 83 16,6 14,4 17,8 83 23,0 16,6 20,2 83 30,1 18,6 22,6 83

UTNA 038 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 2410 6 17,3 16,0 12,9 91 20,1 17,1 14,1 91 21,6 17,6 14,7 91 23,0 18,2 15,3 91 29,2 20,1 17,7 91 35,9 21,8 20,4 92 5 3856 14 20,7 17,4 12,0 91 24,1 18,7 13,0 91 25,8 19,3 13,5 91 27,6 19,9 14,0 91 35,2 22,2 16,2 92 43,5 24,3 18,5 92 5 6420 36 23,6 18,6 11,1 91 27,5 20,1 12,0 91 29,6 20,9 12,4 91 31,6 21,6 12,9 92 40,5 24,3 14,8 92 50,2 26,7 16,8 92 6 2410 6 15,9 15,4 13,4 91 18,7 16,5 14,5 91 20,1 17,1 15,1 91 21,6 17,6 15,7 91 27,7 19,6 18,1 91 34,4 21,3 20,7 92 6 3856 14 19,0 16,6 12,5 91 22,4 18,0 13,5 91 24,1 18,6 14,0 91 25,9 19,3 14,5 91 33,5 21,6 16,7 92 41,7 23,7 19,0 92 6 6420 36 21,7 17,8 11,7 91 25,6 19,3 12,5 91 27,7 20,1 13,0 91 29,7 20,8 13,4 91 38,5 23,5 15,3 92 48,2 25,9 17,4 92 7 2410 6 15,3 14,8 13,7 89 17,2 16,0 14,9 91 18,7 16,5 15,5 91 20,1 17,1 16,0 91 26,2 19,1 18,5 91 32,8 20,8 21,0 92 7 3856 14 17,3 16,0 13,0 91 20,7 17,3 13,9 91 22,4 18,0 14,5 91 24,2 18,6 15,0 91 31,7 21,0 17,1 92 39,9 23,1 19,4 92 7 6420 35 19,8 17,0 12,2 91 23,7 18,5 13,1 91 25,7 19,3 13,5 91 27,8 20,0 14,0 91 36,5 22,8 15,9 92 46,2 25,2 17,9 92 8 2410 6 14,4 14,0 14,3 86 16,1 15,7 15,1 92 17,2 16,0 15,8 91 18,6 16,5 16,4 91 24,7 18,6 18,8 91 31,2 20,3 21,4 92 8 3856 14 15,9 15,4 13,3 92 18,9 16,6 14,4 91 20,7 17,3 14,9 91 22,4 17,9 15,4 91 29,9 20,3 17,6 91 38,0 22,5 19,9 92 8 6420 35 17,9 16,2 12,8 91 21,8 17,7 13,6 91 23,8 18,5 14,1 91 25,8 19,2 14,5 91 34,5 22,0 16,4 92 44,1 24,5 18,4 92 9 2410 6 13,5 13,1 14,9 83 15,3 14,8 15,7 89 16,1 15,7 16,0 92 17,1 16,0 16,8 91 23,1 18,0 19,2 91 29,6 19,8 21,7 92 9 3856 14 14,9 14,4 14,0 88 17,2 16,0 14,9 91 18,9 16,6 15,4 91 20,6 17,3 15,9 91 28,1 19,7 18,0 91 36,2 21,9 20,3 92 9 6420 35 15,9 15,4 13,3 91 19,8 17,0 14,2 91 21,8 17,7 14,6 91 23,8 18,5 15,1 91 32,5 21,3 16,9 92 42,0 23,8 18,9 92

10 2410 6 12,6 12,3 15,5 80 14,4 14,0 16,3 85 15,3 14,8 16,6 89 16,1 15,7 17,0 92 21,6 17,5 19,6 91 28,0 19,4 22,1 92 10 3856 14 13,9 13,5 14,7 84 15,8 15,4 15,3 91 17,1 16,0 15,9 91 18,8 16,6 16,4 91 26,2 19,1 18,5 91 34,3 21,3 20,7 92 10 6420 35 14,9 14,5 14,0 88 17,7 16,2 14,7 91 19,7 16,9 15,2 91 21,8 17,7 15,6 91 30,4 20,5 17,4 91 39,9 23,1 19,4 92

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 4260

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 038

Air flow m3/h 2400 2700 3000 3300 3600 3900 4260 4500 Capacity correction factor 0,78 0,83 0,87 0,90 0,94 0,97 1,00 1,02

Page 17: K11142 ed.5 UTNA GB

17

UTNA 038 performance Heating capacity

UTNA 038 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 1110 3 24,5 10,4 22,2 14,2 17,6 21,7 15,3 25,3 13,1 29,0 12,2 30,4 50 1480 5 26,6 11,7 24,0 15,3 19,0 22,6 16,5 26,1 14,1 29,6 13,1 31,0 50 2258 10 29,0 13,2 26,2 16,7 20,7 23,7 18,0 27,1 15,3 30,5 14,3 31,8 60 1110 3 29,3 13,4 26,9 17,2 22,2 24,7 19,9 28,4 17,6 32,0 16,7 33,5 60 1480 5 31,6 14,8 29,0 18,6 23,9 25,8 21,4 29,4 18,9 33,0 17,9 34,4 60 2258 10 34,5 16,6 31,6 20,2 26,0 27,2 23,3 30,7 20,5 34,1 19,5 35,4 70 1110 3 34,0 16,3 31,6 20,2 26,8 27,7 24,4 31,5 22,1 35,1 21,2 36,6 70 1480 5 36,7 18,0 34,1 21,8 28,9 29,1 26,3 32,7 23,8 36,3 22,8 37,7 70 2258 10 40,0 20,1 37,1 23,7 31,4 30,8 28,6 34,2 25,8 37,7 24,7 39,0

UTNA 038 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 1860 8 34,4 16,3 30,4 19,1 22,5 24,6 18,6 27,3 14,8 30,0 13,3 31,0 40 2972 19 38,3 18,6 33,7 21,2 24,9 26,2 20,5 28,6 16,3 31,0 14,6 31,9 40 4600 42 40,9 20,3 36,0 22,7 26,5 27,3 21,9 29,5 17,4 31,7 15,6 32,6 45 1860 8 38,4 18,7 34,3 21,6 26,3 27,1 22,4 29,8 18,5 32,5 17,0 33,5 45 2972 19 42,6 21,3 38,0 23,9 29,1 29,0 24,7 31,4 20,4 33,8 18,7 34,7 45 4600 41 45,6 23,2 40,6 25,6 31,0 30,2 26,3 32,5 21,8 34,7 19,9 35,5 50 1860 8 42,4 21,2 38,2 24,1 30,2 29,7 26,2 32,4 22,3 35,0 20,7 36,1 50 2972 19 47,0 24,1 42,4 26,7 33,3 31,7 28,9 34,2 24,6 36,6 22,9 37,5 50 4600 40 50,3 26,1 45,3 28,5 35,5 33,2 30,8 35,4 26,2 37,6 24,3 38,5 60 1840 8 50,2 26,0 46,0 29,0 37,8 34,6 33,8 37,4 29,8 40,1 28,2 41,1 60 2455 13 53,8 28,2 49,3 31,0 40,4 36,3 36,1 38,9 31,8 41,4 30,1 42,4 60 3740 27 58,0 30,8 53,0 33,4 43,4 38,3 38,7 40,7 34,1 43,0 32,3 43,9 70 1840 7 58,2 31,0 54,0 33,9 45,6 39,7 41,5 42,5 37,4 45,2 35,8 46,3 70 2455 12 62,4 33,5 57,7 36,3 48,7 41,7 44,2 44,3 39,9 46,9 38,2 47,9 70 3740 26 67,2 36,5 62,1 39,1 52,3 44,1 47,5 46,5 42,8 48,8 40,9 49,8

UTNA 038 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 2410 5 43,5 21,6 38,3 23,8 28,3 28,2 23,4 30,3 18,5 32,3 16,6 33,1 40 3856 12 48,1 24,3 42,3 26,3 31,1 30,0 25,6 31,8 20,3 33,5 18,2 34,2 40 6420 31 51,6 26,5 45,4 28,2 33,3 31,4 27,4 33,0 21,7 34,5 19,4 35,0 45 2410 5 48,5 24,6 43,3 26,9 33,1 31,3 28,1 33,4 23,2 35,5 21,3 36,3 45 3856 12 53,6 27,7 47,7 29,7 36,4 33,4 30,9 35,2 25,5 37,0 23,3 37,6 45 6420 30 57,5 30,1 51,2 31,8 38,9 35,1 33,0 36,6 27,2 38,1 24,9 38,7 50 2410 5 53,5 27,7 48,2 30,0 37,9 34,4 32,9 36,5 27,9 38,6 26,0 39,4 50 3856 12 59,1 31,1 53,2 33,0 41,7 36,8 36,1 38,6 30,6 40,4 28,5 41,1 50 6420 30 63,4 33,7 57,0 35,4 44,6 38,7 38,6 40,3 32,7 41,8 30,4 42,4 60 2270 4 62,7 33,2 57,3 35,6 46,9 40,2 41,9 42,4 36,9 44,6 34,9 45,4 60 3025 7 67,0 35,9 61,3 38,1 50,1 42,2 44,6 44,2 39,3 46,2 37,2 46,9 60 4612 16 72,1 39,0 65,9 40,9 53,7 44,6 47,8 46,3 42,1 48,0 39,8 48,7 70 2270 4 72,6 39,3 67,2 41,8 56,6 46,4 51,4 48,7 46,3 50,8 44,3 51,7 70 3025 7 77,6 42,4 71,7 44,6 60,3 48,8 54,7 50,9 49,3 52,8 47,1 53,6 70 4612 15 83,5 46,0 77,1 47,9 64,7 51,6 58,6 53,4 52,8 55,1 50,4 55,8

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons::

Air flow m3/h 4260

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit.

Page 18: K11142 ed.5 UTNA GB

18

UTNA 051 performance Cooling capacity

UTNA 051 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 2300 3 17,2 16,9 15,8 78 19,0 18,6 16,9 82 20,1 19,0 17,7 82 21,5 19,5 18,4 82 27,2 21,5 21,3 82 33,3 23,2 24,3 82 5 3674 7 19,8 18,8 14,9 82 23,0 20,1 16,2 82 24,7 20,7 16,8 82 26,4 21,3 17,5 82 33,5 23,6 20,2 82 41,2 25,6 23,1 82 5 6135 19 23,2 20,2 14,2 81 27,1 21,7 15,4 82 29,0 22,4 16,0 82 31,0 23,1 16,6 82 39,5 25,8 19,1 82 48,8 28,1 21,8 83 6 2300 3 16,3 16,0 16,2 76 18,1 17,8 17,3 80 19,0 18,7 17,8 82 20,1 19,1 18,6 82 25,8 21,0 21,5 82 31,9 22,8 24,5 82 6 3674 7 18,5 18,1 15,2 81 21,4 19,5 16,5 82 23,0 20,1 17,1 82 24,7 20,7 17,8 82 31,8 23,1 20,5 82 39,5 25,1 23,3 82 6 6135 19 21,4 19,4 14,6 82 25,2 21,0 15,7 82 27,1 21,7 16,3 82 29,1 22,4 17,0 82 37,6 25,1 19,5 82 46,8 27,4 22,1 82 7 2300 3 15,5 15,2 16,6 74 17,3 16,9 17,7 78 18,2 17,8 18,3 80 19,0 18,7 18,8 82 24,4 20,6 21,7 82 30,4 22,4 24,7 82 7 3674 7 17,5 17,1 15,7 79 19,7 18,8 16,8 82 21,4 19,5 17,4 82 23,1 20,1 18,1 82 30,1 22,5 20,8 82 37,7 24,5 23,6 82 7 6135 19 19,5 18,6 14,9 82 23,3 20,2 16,1 82 25,2 20,9 16,7 82 27,2 21,7 17,3 82 35,6 24,4 19,8 82 44,8 26,8 22,5 82 8 2300 3 14,6 14,3 17,0 72 16,4 16,1 18,1 76 17,3 16,9 18,7 78 18,2 17,8 19,2 80 22,9 20,1 22,0 82 28,9 21,9 24,9 82 8 3674 7 16,5 16,1 16,1 76 18,5 18,1 17,1 81 19,7 18,9 17,7 82 21,4 19,5 18,4 82 28,4 21,9 21,1 82 35,9 24,0 23,9 82 8 6135 19 18,1 17,7 15,4 80 21,3 19,4 16,5 82 23,3 20,2 17,1 82 25,3 20,9 17,7 82 33,6 23,7 20,2 82 42,8 26,1 22,8 82 9 2300 3 13,7 13,4 17,5 70 15,5 15,2 18,6 74 16,4 16,1 19,1 76 17,3 17,0 19,6 78 21,5 19,7 22,2 82 27,4 21,5 25,1 82 9 3674 7 15,5 15,2 16,6 74 17,5 17,1 17,6 78 18,5 18,1 18,1 81 19,7 18,9 18,7 82 26,6 21,3 21,4 82 34,2 23,5 24,2 82 9 6135 19 17,0 16,6 15,9 78 19,4 18,7 16,9 82 21,3 19,4 17,4 82 23,3 20,2 18,1 82 31,6 23,0 20,5 82 40,7 25,5 23,1 82

10 2300 3 12,8 12,6 17,9 68 14,6 14,3 19,0 72 15,5 15,2 19,5 74 16,4 16,1 20,1 76 20,0 19,2 22,4 82 25,9 21,1 25,3 82 10 3674 7 14,4 14,2 17,1 72 16,5 16,2 18,1 76 17,5 17,1 18,6 78 18,5 18,1 19,1 81 24,9 20,7 21,6 82 32,3 22,9 24,4 82 10 6135 19 15,8 15,5 16,4 75 18,1 17,7 17,3 80 19,3 18,7 17,8 82 21,2 19,5 18,4 82 29,6 22,3 20,9 82 38,6 24,8 23,5 82

UTNA 051 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 3320 9 23,9 22,4 13,2 90 27,8 24,0 14,4 90 29,8 24,8 15,0 90 31,8 25,5 15,6 90 40,3 28,2 18,1 90 49,5 30,5 20,8 91 5 5307 22 28,5 24,3 12,3 90 33,2 26,2 13,4 90 35,6 27,0 13,9 90 38,1 27,9 14,4 90 48,5 31,1 16,7 91 59,9 33,9 19,1 91 5 8860 56 32,5 26,1 11,5 90 37,9 28,2 12,4 90 40,7 29,2 12,9 90 43,6 30,2 13,3 90 55,7 33,9 15,3 91 69,1 37,2 17,5 91 6 3320 9 22,5 22,0 13,5 91 25,8 23,2 14,8 90 27,8 24,0 15,4 90 29,8 24,7 16,0 90 38,3 27,5 18,5 90 47,4 29,8 21,1 91 6 5307 22 26,2 23,4 12,8 90 30,9 25,2 13,8 90 33,3 26,1 14,3 90 35,7 27,0 14,9 90 46,1 30,2 17,1 91 57,4 33,1 19,5 91 6 8860 55 30,0 24,9 12,0 90 35,3 27,1 12,9 90 38,1 28,1 13,4 90 41,0 29,1 13,9 90 53,0 32,8 15,8 91 66,3 36,2 18,0 91 7 3320 9 21,3 20,8 14,0 88 23,8 22,4 15,2 90 25,8 23,2 15,7 90 27,8 24,0 16,3 90 36,2 26,8 18,8 90 45,2 29,2 21,5 91 7 5307 22 23,9 22,4 13,3 90 28,5 24,3 14,3 90 30,9 25,2 14,8 90 33,3 26,1 15,3 90 43,6 29,4 17,5 91 54,9 32,2 19,9 91 7 8860 55 27,3 23,8 12,6 90 32,7 26,0 13,5 90 35,4 27,0 13,9 90 38,3 28,0 14,4 90 50,3 31,8 16,4 91 63,5 35,2 18,5 91 8 3320 9 20,0 19,6 14,6 84 22,5 22,0 15,4 90 23,7 22,5 16,1 90 25,7 23,2 16,7 90 34,0 26,1 19,2 90 43,0 28,5 21,8 91 8 5307 22 22,1 21,6 13,7 90 26,1 23,4 14,7 90 28,5 24,3 15,2 90 30,9 25,2 15,8 90 41,2 28,5 18,0 90 52,3 31,4 20,3 91 8 8860 55 24,7 22,7 13,1 90 30,0 24,9 14,0 90 32,7 25,9 14,4 90 35,6 26,9 14,9 90 47,5 30,8 16,9 91 60,7 34,2 19,0 91 9 3320 9 18,8 18,4 15,2 81 21,3 20,8 16,0 87 22,5 22,0 16,4 90 23,6 22,5 17,1 90 31,9 25,4 19,5 90 40,8 27,9 22,1 91 9 5307 22 20,7 20,2 14,3 86 23,7 22,4 15,2 90 26,0 23,3 15,7 90 28,5 24,2 16,2 90 38,7 27,6 18,4 90 49,8 30,6 20,8 91 9 8860 55 22,2 21,7 13,6 90 27,2 23,8 14,5 90 30,0 24,8 15,0 90 32,8 25,9 15,4 90 44,7 29,7 17,4 90 57,8 33,2 19,5 91

10 3320 9 17,6 17,2 15,8 78 20,0 19,6 16,6 84 21,3 20,8 16,9 87 22,5 21,9 17,3 90 29,7 24,7 19,9 90 38,6 27,2 22,4 91 10 5307 21 19,4 18,9 14,9 83 22,0 21,5 15,6 89 23,6 22,4 16,1 90 26,0 23,3 16,7 90 36,1 26,8 18,8 90 47,2 29,8 21,2 91 10 8860 54 20,8 20,3 14,3 86 24,4 22,7 15,0 90 27,2 23,8 15,5 90 30,0 24,8 16,0 90 41,8 28,7 17,9 90 54,9 32,2 19,9 91

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 6120

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 051

Air flow m3/h 3000 3300 3600 3900 4200 4500 4800 5100 5400 5700 6120 6300 Capacity correction factor 0,75 0,79 0,82 0,85 0,87 0,90 0,92 0,94 0,96 0,98 1,00 1,01

Page 19: K11142 ed.5 UTNA GB

19

UTNA 051 performance Heating capacity

UTNA 051 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 1515 4 33,6 9,7 30,4 13,5 24,1 21,1 21,0 24,8 17,9 28,5 16,7 30,0 50 2020 7 36,3 10,8 32,8 14,6 26,0 22,0 22,6 25,6 19,3 29,2 17,9 30,6 50 3073 16 39,5 12,2 35,7 15,9 28,2 23,0 24,5 26,5 20,9 29,9 19,4 31,3 60 1515 4 40,0 12,5 36,7 16,3 30,3 24,0 27,2 27,7 24,0 31,4 22,8 32,9 60 2020 7 43,2 13,8 39,6 17,6 32,7 25,0 29,2 28,7 25,8 32,3 24,5 33,7 60 3073 15 46,9 15,5 43,1 19,1 35,4 26,3 31,7 29,8 28,0 33,3 26,5 34,7 70 1515 4 46,5 15,3 43,2 19,2 36,6 26,9 33,4 30,7 30,2 34,4 29,0 35,9 70 2020 7 50,1 16,9 46,5 20,7 39,4 28,2 35,9 31,8 32,5 35,5 31,1 36,9 70 3073 15 54,5 18,8 50,5 22,5 42,7 29,7 38,9 33,2 35,2 36,7 33,7 38,1

UTNA 051 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 2300 3 44,2 14,1 39,1 17,2 29,0 23,2 24,0 26,1 19,1 29,0 17,1 30,1 40 3674 7 50,0 16,6 44,1 19,4 32,6 24,8 27,0 27,5 21,4 30,1 19,2 31,1 40 6135 16 54,8 18,6 48,3 21,2 35,6 26,2 29,4 28,6 23,3 31,0 20,9 31,9 45 2300 3 49,4 16,3 44,2 19,4 34,0 25,5 28,9 28,4 24,0 31,3 22,0 32,4 45 3674 6 55,8 19,1 49,8 21,9 38,2 27,4 32,5 30,0 26,9 32,6 24,6 33,7 45 6135 16 61,1 21,4 54,5 23,9 41,7 29,0 35,4 31,4 29,2 33,8 26,8 34,7 50 2300 3 54,6 18,6 49,3 21,7 39,0 27,7 33,9 30,7 28,9 33,6 26,9 34,7 50 3674 6 61,6 21,6 55,6 24,4 43,8 29,9 38,0 32,6 32,4 35,2 30,1 36,3 50 6135 16 67,4 24,1 60,7 26,7 47,7 31,7 41,4 34,2 35,2 36,6 32,7 37,5 60 2475 3 66,5 23,7 60,9 26,8 50,1 32,8 44,8 35,7 39,6 38,6 37,5 39,8 60 3300 5 71,6 25,9 65,6 28,8 53,8 34,5 48,1 37,3 42,4 40,0 40,2 41,0 60 5037 11 77,7 28,5 71,2 31,3 58,3 36,5 52,0 39,1 45,9 41,6 43,4 42,6 70 2475 3 77,2 28,3 71,6 31,4 60,5 37,5 55,1 40,5 49,7 43,4 47,6 44,6 70 3300 5 83,1 30,9 77,0 33,8 65,0 39,6 59,1 42,4 53,3 45,1 51,0 46,2 70 5037 10 90,2 33,9 83,4 36,7 70,3 42,0 63,9 44,6 57,6 47,1 55,1 48,1

UTNA 051 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 3320 8 60,4 20,7 53,2 23,1 39,2 27,6 32,4 29,8 25,7 32,0 23,1 32,8 40 5307 19 66,7 23,4 58,7 25,5 43,2 29,4 35,6 31,3 28,2 33,1 25,3 33,8 40 8860 48 71,7 25,5 63,0 27,3 46,2 30,8 38,1 32,4 30,2 34,0 27,0 34,6 45 3320 8 67,3 23,7 60,1 26,1 45,9 30,6 39,0 32,8 32,3 35,0 29,6 35,8 45 5307 19 74,3 26,6 66,2 28,7 50,5 32,7 42,9 34,6 35,4 36,4 32,4 37,2 45 8860 47 79,8 29,0 71,0 30,8 54,0 34,3 45,8 35,9 37,8 37,6 34,6 38,2 50 3320 8 74,3 26,6 66,9 29,0 52,6 33,7 45,7 35,9 38,8 38,0 36,1 38,9 50 5307 18 81,9 29,9 73,7 32,0 57,8 36,0 50,1 37,9 42,5 39,8 39,5 40,5 50 8860 46 88,0 32,5 79,1 34,3 61,9 37,8 53,6 39,5 45,4 41,1 42,2 41,7 60 3155 7 87,1 32,1 79,7 34,6 65,3 39,3 58,3 41,6 51,3 43,9 48,6 44,7 60 4210 12 93,1 34,7 85,2 36,9 69,6 41,3 62,1 43,4 54,7 45,4 51,7 46,2 60 6416 25 100,2 37,7 91,5 39,7 74,7 43,6 66,5 45,4 58,5 47,2 55,4 47,9 70 3155 7 100,9 38,0 93,4 40,5 78,7 45,3 71,5 47,7 64,4 49,9 61,6 50,8 70 4210 11 107,9 41,0 99,7 43,3 83,9 47,7 76,2 49,8 68,6 51,9 65,6 52,7 70 6416 24 116,0 44,4 107,1 46,5 89,9 50,4 81,6 52,3 73,4 54,1 70,2 54,8

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 6120

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit

Page 20: K11142 ed.5 UTNA GB

20

UTNA 078 performance Cooling capacity

UTNA 078 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 3231 4 27,9 27,9 14,7 84 31,9 29,7 16,1 84 34,2 30,7 16,7 84 36,5 31,6 17,4 84 46,3 35,09 20,3 84 56,9 38,0 23,3 84 5 7181 15 38,3 32,4 13,2 84 44,7 35,0 14,3 84 48,1 36,3 14,9 84 51,6 37,5 15,4 84 66,4 42,3 17,9 84 82,8 46,5 20,5 85 5 12208 40 43,6 34,8 12,4 84 51,1 37,8 13,4 84 55,0 39,3 13,9 84 59,1 40,7 14,4 84 76,5 46,3 16,5 85 96,1 51,4 18,8 86 6 3231 4 26,4 26,4 15,2 81 29,6 28,8 16,4 84 31,8 29,8 17,0 84 34,2 30,7 17,7 84 43,9 34,2 20,6 84 54,4 37,2 23,5 84 6 7181 15 35,2 31,0 13,6 84 41,6 33,6 14,7 84 44,9 34,9 15,3 84 48,4 36,2 15,9 84 63,1 41,0 18,3 84 79,4 45,3 20,9 85 6 12208 40 40,1 33,2 12,9 84 47,6 36,2 13,9 84 51,5 37,7 14,4 84 55,5 39,2 14,9 84 72,8 44,8 17,0 85 92,3 49,9 19,3 85 7 3231 4 25,0 25,0 15,6 79 28,0 28,0 16,6 83 29,5 28,9 17,3 84 31,8 29,8 18,0 84 41,5 33,4 20,8 84 51,9 36,5 23,8 84 7 7181 15 32,0 29,7 14,1 84 38,4 32,3 15,2 84 41,8 33,7 15,7 84 45,1 34,9 16,3 84 59,7 39,8 18,7 84 75,9 44,1 21,3 85 7 12208 40 36,6 31,6 13,4 84 44,0 34,7 14,4 84 47,9 36,2 14,9 84 51,9 37,7 15,4 84 69,1 43,3 17,5 85 88,4 48,5 19,8 85 8 3231 4 23,6 23,6 16,1 77 26,5 26,5 17,1 81 28,1 28,1 17,6 83 29,4 28,9 18,3 84 39,0 32,6 21,1 84 49,3 35,7 24,0 84 8 7181 15 28,9 28,3 14,5 84 35,2 31,0 15,6 84 38,5 32,3 16,2 84 41,9 33,6 16,7 84 56,3 38,5 19,1 84 72,4 42,9 21,6 84 8 12208 40 33,0 30,1 13,9 84 40,4 33,2 14,9 84 44,2 34,7 15,4 84 48,2 36,2 15,9 84 65,3 41,8 18,0 84 84,4 47,1 20,3 85 9 3231 4 22,2 22,2 16,6 74 25,1 25,1 17,6 79 26,6 26,6 18,1 81 28,1 28,1 18,6 83 36,5 31,7 21,4 84 46,7 35,0 24,3 84 9 7181 15 26,4 26,4 15,2 81 31,9 29,7 16,1 84 35,2 31,0 16,6 84 38,5 32,3 17,2 84 52,9 37,3 19,5 84 68,8 41,7 22,0 84 9 12208 39 29,4 28,5 14,5 84 36,7 31,6 15,4 84 40,5 33,2 15,9 84 44,4 34,7 16,4 84 61,4 40,4 18,5 84 80,4 45,6 20,7 85

10 3231 4 20,7 20,7 17,1 72 23,7 23,7 18,1 76 25,2 25,2 18,6 78 26,7 26,7 19,1 81 34,0 30,9 21,6 84 44,1 34,2 24,6 84 10 7181 14 24,6 24,6 15,8 78 28,6 28,4 16,5 84 31,8 29,8 17,0 84 35,2 31,1 17,6 84 49,4 36,1 19,9 84 65,2 40,6 22,4 84 10 12208 39 26,3 26,3 15,2 81 32,9 30,1 15,9 84 36,7 31,6 16,4 84 40,6 33,2 16,9 84 57,4 38,9 19,0 84 76,3 44,2 21,2 85

UTNA 078 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 4304 3 37,2 34,3 12,5 92 43,3 36,9 13,7 92 46,5 38,2 14,2 92 49,7 39,4 14,8 92 63,2 43,8 17,4 92 77,8 47,6 20,1 92 5 9564 12 50,7 40,3 10,5 92 59,4 43,8 11,4 92 64,0 45,6 11,8 92 68,7 47,2 12,2 92 88,8 53,7 14,1 93 111,3 59,5 16,1 93 5 16259 32 56,8 43,1 9,6 92 66,7 47,1 10,3 92 71,9 49,1 10,6 92 77,2 51,1 10,9 93 100,4 58,6 12,4 93 126,8 65,7 14,1 94 6 4304 3 34,2 33,0 13,0 92 40,2 35,6 14,1 92 43,3 36,9 14,7 92 46,5 38,1 15,3 92 59,9 42,6 17,8 92 74,3 46,5 20,5 92 6 9564 12 46,7 38,5 11,1 92 55,3 42,0 12,0 92 59,8 43,7 12,4 92 64,5 45,4 12,8 92 84,4 51,9 14,7 93 106,8 57,7 16,7 93 6 16259 32 52,3 41,0 10,3 92 62,2 45,1 10,9 92 67,3 47,0 11,3 92 72,7 49,0 11,6 92 95,7 56,6 13,1 93 121,9 63,6 14,7 94 7 4304 3 32,0 32,0 13,3 92 37,0 34,4 14,5 92 40,1 35,7 15,1 92 43,3 36,9 15,7 92 56,5 41,5 18,1 92 70,9 45,4 20,8 92 7 9564 12 42,6 36,6 11,8 92 51,2 40,2 12,6 92 55,6 41,9 13,0 92 60,2 43,6 13,4 92 80,0 50,1 15,2 93 102,1 56,0 17,3 93 7 16259 32 47,8 39,0 11,0 92 57,6 43,0 11,6 92 62,7 45,0 12,0 92 68,0 46,9 12,3 92 90,9 54,5 13,8 93 116,9 61,6 15,4 94 8 4304 3 30,1 30,1 13,9 88 33,9 33,2 14,9 92 36,9 34,4 15,5 92 40,0 35,7 16,1 92 53,2 40,3 18,5 92 67,4 44,4 21,2 92 8 9564 12 38,4 34,8 12,4 92 46,9 38,4 13,2 92 51,3 40,1 13,6 92 55,9 41,9 14,0 92 75,5 48,4 15,8 92 97,5 54,3 17,8 93 8 16259 32 43,2 36,9 11,7 92 52,9 40,9 12,3 92 58,0 42,9 12,7 92 63,2 44,9 13, 92 85,9 52,5 14,5 93 111,7 59,6 16,1 93 9 4304 3 28,3 28,3 14,5 85 32,1 32,1 15,3 91 33,7 33,2 15,9 92 36,8 34,5 16,5 92 49,8 39,2 18,9 92 63,9 43,3 21,5 92 9 9564 12 34,1 33,0 13,0 92 42,6 36,6 13,8 92 47,0 38,4 14,2 92 51,5 40,1 14,6 92 71,0 46,7 16,4 92 92,7 52,7 18,4 93 9 16259 32 38,5 34,8 12,4 92 48,1 38,9 13,0 92 53,2 40,9 13,3 92 58,4 42,9 13,7 92 80,9 50,5 15,1 92 106,5 57,6 16,7 93

10 4304 3 26,5 26,5 15,2 81 30,3 30,3 15,9 88 32,2 32,2 16,2 91 33,5 33,3 16,9 92 46,4 38,0 19,3 92 60,3 42,2 21,9 92 10 9564 2 30,6 30,6 13,8 89 38,2 34,8 14,4 92 42,6 36,6 14,8 92 47,1 38,3 15,2 92 66,4 45,0 17,0 92 87,9 51,0 19,0 93 10 16259 32 33,6 32,8 13,0 92 43,2 36,9 13,7 92 48,3 38,9 14,0 92 53,4 40,8 14,4 92 75,8 48,5 15,8 92 101,2 55,7 17,4 93

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 8.580

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 078

Air flow m3/h 4.300 5.700 8.580 Capacity correction factor 0,65 0,78 1,00

Page 21: K11142 ed.5 UTNA GB

21

UTNA 078 performance Heating capacity

UTNA 078 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 2261 3 51,8 12,3 47,2 15,8 38,1 22,7 33,4 26,2 28,8 29,6 26,9 31,0 50 3015 4 55,8 13,7 50,9 17,0 41,0 23,7 36,0 27,0 31,0 30,3 28,9 31,7 50 5025 11 61,5 15,5 56,1 18,7 45,2 25,1 39,7 28,2 34,1 31,4 31,9 32,6 60 2261 3 61,7 15,6 57,2 19,1 48,0 26,0 43,3 29,5 38,6 32,9 36,8 34,3 60 3015 4 66,5 17,2 61,6 20,6 51,7 27,3 46,7 30,6 41,6 33,9 39,6 35,2 60 5025 11 73,1 19,4 67,7 22,6 56,8 29,0 51,3 32,1 45,7 35,3 43,5 36,5 70 2261 3 71,8 19,0 67,2 22,5 58,0 29,4 53,3 32,8 48,7 36,3 46,8 37,6 70 3015 4 77,3 20,8 72,4 24,2 62,4 30,9 57,4 34,2 52,3 37,5 50,3 38,8 70 5025 10 84,9 23,4 79,5 26,6 68,6 32,9 63,0 36,1 57,5 39,2 55,2 40,5

UTNA 078 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 3231 3 67,9 17,7 60,5 20,2 45,7 25,3 38,2 27,8 30,6 30,2 27,6 31,2 40 7181 13 80,1 21,8 71,4 23,8 53,8 28,0 44,9 30,0 36,0 32,0 32,4 32,8 40 12208 34 84,9 23,4 75,7 25,3 57,0 29,0 47,6 30,9 38,1 32,7 34,4 33,5 45 3231 3 75,8 20,3 68,4 22,9 53,5 27,9 46,0 30,4 38,5 32,8 35,4 33,8 45 7181 13 89,3 24,8 80,6 26,9 62,9 31,0 54,1 33,1 45,2 35,1 41,6 35,9 45 12208 34 94,6 26,6 85,3 28,5 66,7 32,3 57,3 34,1 47,8 36,0 44,0 36,7 50 3231 3 83,8 23,0 76,4 25,5 61,5 30,5 53,9 33,0 46,3 35,5 43,3 36,5 50 7181 13 98,6 27,9 89,8 30,0 72,2 34,1 63,3 36,1 54,4 38,2 50,8 39,0 50 12208 33 104,4 29,9 95,1 31,8 76,4 35,5 67,0 37,4 57,5 39,2 53,7 39,9 60 3656 4 103,2 29,5 95,5 31,9 80,0 36,7 72,2 39,1 64,3 41,5 61,1 42,4 60 4875 6 110,0 31,8 101,8 34,0 85,2 38,5 76,9 40,7 68,5 42,9 65,1 43,8 60 8125 16 119,0 34,8 110,1 36,8 92,1 40,8 83,1 42,8 74,0 44,7 70,4 45,5 70 3656 4 119,9 35,0 112,1 37,5 96,6 42,3 88,7 44,6 80,9 47,0 77,7 48,0 70 4875 6 127,7 37,7 119,4 39,9 102,8 44,4 94,5 46,6 86,1 48,8 82,7 49,6 70 8125 15 138,0 41,1 129,1 43,1 111,1 47,1 102,0 49,1 92,9 51,1 89,3 51,8

UTNA 078 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 4304 3 86,8 24,0 77,4 25,8 58,3 29,5 48,7 31,3 39,0 33,0 35,2 33,8 40 9564 11 99,6 28,3 88,7 29,6 66,8 32,3 55,7 33,6 44,6 34,9 40,2 35,4 40 16259 28 104,3 29,9 92,9 31,0 69,8 33,3 58,3 34,5 46,7 35,6 42,0 36,0 45 4304 3 96,9 27,4 87,4 29,2 68,3 32,8 58,7 34,6 49,0 36,4 45,1 37,1 45 9564 11 111,1 32,1 100,1 33,5 78,1 36,1 67,1 37,4 56,0 38,7 51,5 39,2 45 16259 27 116,2 33,8 104,7 35,0 81,7 37,3 70,1 38,4 58,5 39,5 53,8 40,0 50 4304 3 107,1 30,8 97,6 32,6 78,4 36,2 68,7 38,0 59,1 39,7 55,2 40,4 50 9564 10 122,5 35,9 111,6 37,3 89,5 39,9 78,5 41,2 67,3 42,5 62,9 43,0 50 16259 27 128,1 37,8 116,6 39,0 93,5 41,3 82,0 42,4 70,3 43,5 65,7 43,9 60 4473 3 128,7 38,0 119,1 39,8 99,6 43,3 89,8 45,0 80,0 46,7 76,0 47,4 60 5963 4 136,4 40,6 126,1 42,1 105,5 45,2 95,1 46,8 84,7 48,3 80,5 48,9 60 9939 11 146,1 43,8 135,1 45,1 112,9 47,7 101,8 49,0 90,6 50,3 86,1 50,8 70 4473 3 149,5 44,9 139,8 46,7 120,2 50,2 110,4 51,9 100,6 53,6 96,6 54,3 70 5963 4 158,3 47,9 148,0 49,4 127,3 52,5 116,9 54,0 106,4 55,5 102,2 56,1 70 9939 10 169,3 51,6 158,3 52,9 136,1 55,5 124,9 56,7 113,7 58,0 109,2 58,5

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 8.580

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit

Page 22: K11142 ed.5 UTNA GB

22

UTNA 107 performance Cooling capacity

UTNA 107 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 4691 3 39,9 39,6 14,4 85 46,4 42,5 15,7 85 49,8 43,9 16,3 85 53,2 45,2 17,0 85 67,6 50,1 19,8 85 83,0 54,4 22,7 85 5 10425 12 55,5 46,3 12,7 85 64,9 50,1 13,8 85 69,9 52,0 14,3 85 74,9 53,8 14,9 85 96,5 60,8 17,2 86 120,6 66,9 19,7 86 5 17723 31 63,1 49,7 11,9 85 74,0 54,2 12,8 85 79,8 56,3 13,3 86 85,6 58,4 13,8 86 111,0 66,6 15,8 86 139,7 74,0 18,0 87 6 4691 3 38,1 38,1 14,7 84 43,1 41,1 16, 85 46,4 42,5 16,6 85 49,8 43,9 17,3 85 64,0 48,9 20,1 85 79,4 53,3 23,0 85 6 10425 12 51,0 44,3 13,2 85 60,4 48,2 14,3 85 65,3 50,1 14,8 85 70,3 51,9 15,3 85 91,7 58,9 17,7 86 115,6 65,1 20,1 86 6 17723 31 58,1 47,5 12,4 85 69,0 51,9 13,4 85 74,6 54,1 13,8 85 80,5 56,2 14,3 86 105,7 64,4 16,3 86 134,1 71,9 18,5 87 7 4691 3 36,1 36,1 15,2 81 40,4 40,4 16,2 86 43,0 41,2 17,0 85 46,3 42,6 17,6 85 60,4 47,7 20,4 85 75,6 52,2 23,3 85 7 10425 12 46,5 42,4 13,7 85 55,8 46,3 14,7 85 60,6 48,2 15,3 85 65,6 50,0 15,8 85 86,9 57,1 18,1 86 110,5 63,4 20,6 86 7 17723 31 53,0 45,2 13,0 85 63,8 49,7 13,9 85 69,4 51,8 14,4 85 75,2 54,0 14,8 85 100,3 62,2 16,8 86 128,5 69,8 19, 87 8 4691 3 34,0 34,0 15,7 79 38,3 38,3 16,7 83 40,5 40,5 17,1 86 42,9 41,3 17,9 85 56,8 46,5 20,7 85 71,9 51, 23,6 85 8 10425 12 41,9 40,4 14,2 85 51,1 44,3 15,2 85 55,9 46,3 15,7 85 60,9 48,2 16,3 85 82,0 55,2 18,5 85 105,4 61,6 21,0 86 8 17723 31 47,8 42,9 13,5 85 58,6 47,4 14,4 85 64,2 49,6 14,9 85 69,9 51,8 15,4 85 94,7 60,1 17,4 86 122,7 67,7 19,5 86 9 4691 3 31,9 31,9 16,2 76 36,2 36,2 17,2 81 38,4 38,4 17,6 83 40,6 40,6 18,1 85 53,2 45,3 21,0 85 68,2 50,0 23,8 85 9 10425 12 37,8 37,8 14,8 83 46,4 42,4 15,7 85 51,2 44,4 16,2 85 56,0 46,3 16,7 85 77,0 53,4 19,0 85 100,2 59,9 21,4 86 9 17723 30 42,6 40,7 14,1 85 53,2 45,2 15,0 85 58,8 47,4 15,5 85 64,5 49,6 15,9 85 89,1 57,9 17,9 86 116,9 65,6 20,0 86

10 4691 3 29,8 29,8 16,7 74 34,2 34,2 17,7 78 36,3 36,3 18,2 80 38,5 38,5 18,6 83 49,6 44,2 21,2 85 64,4 48,8 24,1 85 10 10425 12 35,3 35,3 15,4 80 41,6 40,6 16,1 85 46,3 42,5 16,6 85 51,2 44,4 17,2 85 71,9 51,7 19,4 85 95,0 58,2 21,8 86 10 17723 30 37,6 37,6 14,8 83 47,8 43,0 15,5 85 53,3 45,2 16,0 85 59,0 47,4 16,5 85 83,4 55,8 18,4 86 111,0 63,5 20,5 86

UTNA 107 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 6400 5 56,6 49,9 11,9 93 65,9 53,8 12,9 93 70,7 55,6 13,5 93 75,6 57,4 14,0 93 96,2 64,0 16,4 93 118,4 69,7 19,0 93 5 14222 22 75,2 58,3 9,8 93 88,3 63,5 10,5 93 95,1 66,1 10,9 93 102,1 68,6 11,3 93 132,2 78,3 12,9 94 166,1 87,1 14,8 94 5 24177 57 82,9 61,9 8,9 93 97,4 67,8 9,5 93 105,1 70,7 9,8 94 112,9 73,6 10,1 94 147,1 84,8 11,3 94 186,0 95,5 12,7 95 6 6400 5 51,9 47,9 12,3 93 61,2 51,8 13,4 93 65,9 53,6 13,9 93 70,8 55,5 14,5 93 91,2 62,2 16,9 93 113,2 67,9 19,5 93 6 14222 21 69,3 55,5 10,5 93 82,2 60,8 11,2 93 88,9 63,4 11,6 93 95,9 65,9 11,9 93 125,8 75,6 13,6 94 159,4 84,5 15,4 94 6 24177 56 76,4 58,8 9,7 93 90,9 64,8 10,2 93 98,5 67,7 10,5 93 106,3 70,6 10,8 93 140,2 81,8 12,1 94 178,9 92,4 13,5 95 7 6400 5 47,2 45,9 12,8 93 56,4 49,8 13,9 93 61,1 51,7 14,4 93 65,9 53,6 15,0 93 86,1 60,4 17,3 93 108,0 66,2 19,9 93 7 14222 21 63,2 52,8 11,1 93 76,0 58,1 11,9 93 82,7 60,7 12,2 93 89,6 63,2 12,6 93 119,3 72,9 14,2 94 152,6 81,9 16,1 94 7 24177 56 69,9 55,8 10,4 93 84,2 61,7 11,0 93 91,8 64,6 11,3 93 99,5 67,5 11,6 93 133,2 78,8 12,8 94 171,7 89,4 14,2 95 8 6400 5 44,5 44,5 13,2 93 51,5 47,9 14,3 93 56,2 49,8 14,9 93 61,0 51,7 15,4 93 81,0 58,6 17,7 93 102,7 64,5 20,3 93 8 14222 21 57,0 50,1 11,8 93 69,8 55,4 12,5 93 76,4 58,0 12,9 93 83,2 60,5 13,3 93 112,6 70,3 14,9 93 145,7 79,3 16,7 94 8 24177 56 63,1 52,7 11,2 93 77,4 58,7 11,7 93 84,9 61,6 12,0 93 92,6 64,5 12,3 93 126,1 75,8 13,5 94 164,3 86,4 15,0 94 9 6400 5 41,8 41,8 13,8 89 46,6 46,0 14,8 93 51,3 47,9 15,3 93 56,0 49,8 15,9 93 75,9 56,8 18,2 93 97,3 62,9 20,7 93 9 14222 21 50,7 47,4 12,5 93 63,4 52,7 13,2 93 70,0 55,3 13,5 93 76,7 57,8 13,9 93 105,9 67,7 15,5 93 138,7 76,7 17,3 94 9 24177 55 56,3 49,7 11,9 93 70,5 55,7 12,4 93 77,9 58,6 12,7 93 85,6 61,5 13,0 93 118,8 72,8 14,3 94 156,7 83,5 15,7 94

10 6400 5 39,0 39,0 14,5 85 44,7 44,7 15,1 92 46,3 46,0 15,8 93 51,0 47,9 16,3 93 70,7 55,0 18,6 93 92,0 61,2 21,1 93 10 14222 21 44,2 44,2 13,2 92 56,9 50,0 13,8 93 63,4 52,7 14,2 93 70,1 55,2 14,6 93 99,1 65,1 16,1 93 131,5 74,2 17,9 94 10 24177 55 49,3 46,8 12,6 93 63,4 52,7 13,2 93 70,8 55,6 13,5 93 78,4 58,5 13,7 93 111,4 69,8 15,0 93 149,0 80,5 16,4 94

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 11.770

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 107

Air flow m3/h 5.800 7.800 11.770 Capacity correction factor 0,64 0,78 1,00

Page 23: K11142 ed.5 UTNA GB

23

UTNA 107 performance Heating capacity

UTNA 107 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 3250 1 73,9 13,0 67,4 16,4 54,3 23,2 47,7 26,6 41,0 30,0 38,3 31,3 50 4334 2 79,9 14,4 72,9 17,7 58,7 24,3 51,5 27,5 44,3 30,8 41,4 32,1 50 7223 5 88,3 16,5 80,6 19,6 64,9 25,8 56,9 28,9 48,9 31,9 45,7 33,1 60 3250 1 88,2 16,5 81,7 19,9 68,5 26,7 61,9 30,1 55,2 33,4 52,5 34,8 60 4334 2 95,2 18,2 88,2 21,5 74,0 28,0 66,8 31,3 59,6 34,5 56,7 35,8 60 7223 5 105,1 20,6 97,3 23,7 81,6 29,9 73,7 32,9 65,7 36,0 62,5 37,2 70 3250 1 102,6 20,0 96,1 23,4 82,9 30,2 76,2 33,6 69,5 36,9 66,8 38,3 70 4334 2 110,7 22,0 103,7 25,2 89,4 31,8 82,2 35,0 75,0 38,3 72,1 39,6 70 7223 5 122,0 24,7 114,3 27,8 98,6 34,0 90,6 37,1 82,6 40,1 79,4 41,3

UTNA 107 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 4691 3 97,8 18,8 87,2 21,2 65,8 26,0 55,0 28,4 44,1 30,7 39,7 31,7 40 10425 10 114,9 23,0 102,4 24,9 77,1 28,8 64,4 30,7 51,6 32,6 46,5 33,3 40 17723 27 121,6 24,6 108,3 26,4 81,6 29,9 68,1 31,6 54,6 33,3 49,2 34,0 45 4691 2 109,3 21,6 98,6 24,0 77,1 28,8 66,3 31,1 55,4 33,5 51,0 34,4 45 10425 10 128,1 26,2 115,6 28,1 90,3 32,0 77,5 33,9 64,8 35,8 59,6 36,5 45 17723 26 135,5 28,0 122,2 29,8 95,4 33,2 81,9 35,0 68,4 36,7 63,0 37,3 50 4691 2 120,8 24,4 110,1 26,8 88,5 31,6 77,7 33,9 66,7 36,3 62,4 37,2 50 10425 10 141,4 29,4 128,8 31,4 103,5 35,2 90,7 37,1 77,9 39,0 72,8 39,7 50 17723 26 149,4 31,4 136,1 33,1 109,3 36,6 95,8 38,3 82,3 40,0 76,9 40,7 60 5230 3 148,0 31,1 137,0 33,4 114,7 37,9 103,5 40,2 92,2 42,5 87,7 43,4 60 6973 5 157,7 33,4 145,9 35,5 122,1 39,7 110,1 41,8 98,1 43,9 93,3 44,7 60 11622 12 170,3 36,5 157,6 38,4 131,8 42,1 118,9 44,0 105,9 45,8 100,7 46,5 70 5230 3 171,9 36,9 160,9 39,2 138,5 43,7 127,3 46,0 115,9 48,2 111,4 49,1 70 6973 5 183,0 39,6 171,2 41,7 147,4 45,9 135,4 48,0 123,3 50,0 118,5 50,9 70 11622 11 197,5 43,1 184,7 45,0 158,9 48,7 146,0 50,6 133,0 52,0 127,7 53,1

UTNA 107 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 6400 5 127,3 26,0 113,4 27,6 85,4 30,8 71,3 32,4 57,2 33,9 51,5 34,5 40 14222 19 143,3 29,9 127,6 31,1 96,0 33,4 80,1 34,5 64,2 35,6 57,8 36,1 40 24177 49 148,9 31,3 132,5 32,3 99,6 34,3 83,1 35,2 66,6 36,2 60,0 36,6 45 6400 4 142,0 29,6 128,1 31,2 100,0 34,4 85,9 35,9 71,7 37,5 66,0 38,1 45 14222 18 159,7 33,9 143,9 35,0 112,2 37,3 96,3 38,5 80,4 39,6 74,0 40,0 45 24177 48 165,8 35,4 149,4 36,4 116,5 38,4 100,0 39,3 83,4 40,3 76,8 40,7 50 6400 4 156,8 33,2 142,8 34,8 114,7 37,9 100,5 39,5 86,3 41,0 80,6 41,6 50 14222 18 176,0 37,9 160,3 39,0 128,6 41,3 112,6 42,4 96,7 43,5 90,3 44,0 50 24177 47 182,7 39,5 166,3 40,5 133,3 42,5 116,8 43,5 100,2 44,4 93,6 44,8 60 6384 4 186,4 40,4 172,4 42,0 144,1 45,1 129,9 46,7 115,7 48,2 110,0 48,8 60 8512 7 196,5 42,9 181,7 44,2 151,9 47,0 136,9 48,3 121,9 49,7 115,8 50,2 60 14187 18 208,9 45,9 193,1 47,0 161,3 49,3 145,4 50,4 129,4 51,5 123,0 52,0 70 6384 4 216,2 47,7 202,1 49,2 173,8 52,3 159,6 53,9 145,3 55,4 139,6 56,0 70 8512 7 227,8 50,5 212,9 51,9 183,0 54,6 168,0 55,9 153,0 57,3 146,9 57,8 70 14187 17 241,9 53,9 226,1 55,1 194,3 57,3 178,3 58,4 162,3 59,5 155,9 60,0

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 11.770

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit.

Page 24: K11142 ed.5 UTNA GB

24

UTNA 130 performance Cooling capacity

UTNA 130 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 5245 3 45,4 45,4 14,9 83 51,7 48,7 16,2 83 55,4 50,2 16,9 83 59,2 51,7 17,6 83 75,1 57,4 20,5 83 92,2 62,2 23,5 84 5 11656 14 62,1 52,9 13,4 83 72,7 57,3 14,5 83 78,2 59,4 15,1 83 83,8 61,4 15,7 83 107,8 69,1 18,1 84 134,4 76,0 20,8 84 5 19815 38 71,0 56,9 12,6 83 83,2 61,9 13,6 83 89,6 64,3 14,1 84 96,2 66,7 14,6 84 124,5 75,7 16,8 84 156,3 83,9 19,2 85 6 5245 3 43,1 43,1 15,4 80 47,9 47,2 16,5 83 51,6 48,8 17,2 83 55,4 50,4 17,9 83 71,1 56,1 20,8 83 88,1 61,0 23,8 84 6 11656 14 57,1 50,8 13,8 83 67,6 55,2 14,9 83 73,0 57,3 15,5 83 78,6 59,3 16,1 83 102,4 67,1 18,5 84 128,8 74,1 21,2 84 6 19815 38 65,3 54,4 13,1 83 77,5 59,4 14,1 83 83,9 61,8 14,6 83 90,4 64,2 15,1 84 118,5 73,3 17,3 84 150,0 81,6 19,6 85 7 5245 3 40,7 40,7 15,8 78 45,6 45,6 16,9 82 47,8 47,4 17,5 83 51,5 48,9 18,2 83 67,2 54,7 21,0 83 84,0 59,7 24,0 84 7 11656 14 52,0 48,6 14,3 83 62,4 53,0 15,4 83 67,8 55,1 15,9 83 73,3 57,2 16,5 83 97,0 65,1 19,0 84 123,2 72,1 21,5 84 7 19815 38 59,6 51,9 13,6 83 71,7 56,9 14,6 83 78,0 59,3 15,1 83 84,5 61,7 15,6 84 112,4 70,9 17,8 84 143,7 79,3 20,1 85 8 5245 3 38,4 38,4 16,3 76 43,3 43,3 17,3 80 45,7 45,7 17,8 82 47,7 47,5 18,5 83 63,2 53,4 21,3 83 79,8 58,6 24,3 84 8 11656 14 46,9 46,4 14,7 83 57,2 50,9 15,8 83 62,5 53,0 16,4 83 68,0 55,1 16,9 83 91,4 63,1 19,4 84 117,4 70,2 21,9 84 8 19815 37 53,8 49,3 14,1 83 65,8 54,4 15,1 83 72,0 56,9 15,6 83 78,5 59,3 16,1 83 106,1 68,5 18,3 84 137,2 77,0 20,6 84 9 5245 3 36,1 36,1 16,8 73 41,0 41,0 17,8 78 43,4 43,4 18,3 80 45,9 45,9 18,8 82 59,1 52,1 21,6 83 75,7 57,3 24,5 84 9 11656 14 43,1 43,1 15,4 80 51,9 48,8 16,2 83 57,2 50,9 16,8 83 62,6 53,1 17,4 83 85,8 61,1 19,8 84 111,6 68,3 22,3 84 9 19815 37 47,8 46,8 14,6 83 59,8 51,9 15,6 83 66,0 54,4 16,1 83 72,4 56,8 16,6 83 99,8 66,2 18,7 84 130,7 74,7 21,0 84

10 5245 3 33,7 33,7 17,2 71 38,6 38,6 18,3 75 41,1 41,1 18,8 77 43,5 43,5 19,3 80 55,1 50,8 21,8 83 71,5 56,1 24,7 84 10 11656 14 40,2 40,2 15,9 77 46,1 46,1 16,8 83 51,7 48,8 17,2 83 57,1 51,0 17,8 83 80,2 59,1 20,1 83 105,7 66,4 22,7 84 10 19815 37 43,0 43,0 15,4 80 53,6 49,5 16,1 83 59,8 52,0 16,6 83 66,1 54,4 17,1 83 93,4 63,8 19,2 84 124,0 72,4 21,5 84

UTNA 130BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 7299 6 64,2 57,9 12,4 91 74,7 62,3 13,5 91 80,1 64,5 14,1 92 85,6 66,6 14,7 92 108,8 74,1 17,1 92 133,9 80,6 19,8 92 5 16221 27 86,0 67,7 10,4 92 100,8 73,6 11,2 92 108,5 76,6 11,6 92 116,5 79,4 12,1 92 150,6 90,4 13,9 92 188,9 100,3 15,9 93 5 27576 72 95,3 72,0 9,6 92 112,0 78,8 10,2 92 120,7 82,1 10,5 92 129,7 85,4 10,9 92 168,7 98,1 12,3 93 213,1 110,0 13,9 94 6 7299 6 58,9 55,7 12,8 92 69,3 60,2 13,9 92 74,7 62,3 14,5 92 80,1 64,4 15,1 92 103,2 72,0 17,6 92 128,0 78,6 20,2 92 6 16221 27 79,1 64,5 11,1 92 93,8 70,5 11,9 92 101,5 73,5 12,3 92 109,4 76,4 12,7 92 143,3 87,3 14,5 92 181,2 97,3 16,5 93 6 27576 71 87,8 68,5 10,3 92 104,4 75,3 10,9 92 113,1 78,6 11,2 92 122,0 81,9 11,6 92 160,8 94,6 13,0 93 204,8 106,6 14,6 94 7 7299 6 53,5 53,5 13,3 92 63,9 58,0 14,4 92 69,2 60,1 14,9 92 74,6 62,2 15,5 92 97,4 70,0 18,0 92 122,1 76,7 20,6 92 7 16221 27 72,2 61,4 11,7 91 86,8 67,4 12,5 92 94,4 70,4 12,9 92 102,2 73,3 13,3 92 135,8 84,3 15,1 92 173,4 94,4 17,1 93 7 27576 71 80,2 65,0 11,0 91 96,7 71,8 11,6 92 105,3 75,2 11,9 92 114,2 78,4 12,3 92 152,7 91,2 13,7 93 196,4 103,2 15,3 93 8 7299 6 51,2 51,2 13,7 89 58,4 55,8 14,8 92 63,6 58,0 15,4 92 69,0 60,1 16, 92 91,7 68,0 18,4 92 116,1 74,8 21, 92 8 16221 27 65,1 58,3 12,3 91 79,6 64,4 13,1 92 87,1 67,4 13,5 92 94,9 70,2 13,9 92 128,2 81,4 15,7 92 165,5 91,5 17,7 92 8 27576 71 72,5 61,6 11,7 92 88,8 68,3 12,3 92 97,4 71,7 12,6 92 106,2 75,0 13,0 92 144,4 87,8 14,4 92 187,8 99,8 16, 93 9 7299 6 48,0 48,0 14,4 86 54,5 54,5 15,1 92 58,1 55,8 15,8 92 63,4 58,0 16,4 92 85,8 66,0 18,8 92 110,0 73,0 21,4 92 9 16221 27 57,9 55,3 12,9 91 72,2 61,3 13,7 92 79,7 64,3 14,1 92 87,4 67,3 14,5 92 120,5 78,4 16,3 92 157,5 88,6 18,2 92 9 27576 70 64,6 58,1 12,4 91 80,8 64,9 13,0 92 89,3 68,3 13,3 92 98,1 71,6 13,7 92 136,0 84,4 15,1 92 179,1 96,5 16,7 93

10 7299 6 44,9 44,9 15,0 82 51,4 51,4 15,7 89 54,6 54,6 16,0 92 57,7 55,9 16,8 92 80,0 64,0 19,2 92 103,9 71,1 21,7 92 10 16221 27 51,3 51,3 13,7 89 64,8 58,3 14,3 92 72,2 61,3 14,7 92 79,9 64,3 15,1 92 112,7 75,5 16,9 92 149,4 85,8 18,8 92 10 27576 70 56,5 54,7 13,0 91 72,6 61,5 13,7 91 81,1 64,9 14,0 92 89,8 68,2 14,3 92 127,4 81,1 15,7 92 170,1 93,2 17,3 93

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 14.300

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 130

Air flow m3/h 7.100 9.500 14.300 Capacity correction factor 0,65 0,79 1,00

Page 25: K11142 ed.5 UTNA GB

25

UTNA 130 performance Heating capacity

UTNA 130 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 3646 2 82,6 11,6 75,3 15,1 60,7 22,2 53,3 25,7 45,9 29,2 42,9 30,6 50 4861 3 89,4 12,9 81,5 16,3 65,7 23,2 57,7 26,6 49,6 29,9 46,4 31,3 50 8102 7 99,0 14,8 90,3 18,1 72,7 24,6 63,8 27,8 54,9 31,0 51,3 32,3 60 3646 2 98,6 14,8 91,3 18,3 76,6 25,4 69,2 28,9 61,7 32,4 58,7 33,8 60 4861 3 106,6 16,4 98,7 19,8 82,8 26,6 74,8 30,0 66,7 33,4 63,4 34,7 60 8102 6 117,8 18,6 109,1 21,9 91,5 28,4 82,7 31,6 73,7 34,8 70,1 36,1 70 3646 2 114,7 18,0 107,4 21,5 92,7 28,6 85,3 32,1 77,8 35,6 74,8 37,0 70 4861 3 123,9 19,8 116,0 23,3 100,1 30,1 92,1 33,5 84,0 36,8 80,7 38,2 70 8102 6 136,8 22,4 128,1 25,7 110,5 32,2 101,6 35,4 92,7 38,6 89,1 39,9

UTNA 130 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 5245 3 110,6 17,2 98,6 19,8 74,4 24,9 62,2 27,5 49,9 30,0 45,0 31,0 40 11656 13 130,9 21,2 116,7 23,4 87,9 27,6 73,4 29,7 58,9 31,8 53,0 32,6 40 19815 33 139,1 22,9 123,9 24,8 93,3 28,7 77,9 30,6 62,5 32,5 56,3 33,3 45 5245 3 123,5 19,8 111,5 22,4 87,3 27,5 75,0 30,0 62,7 32,6 57,7 33,6 45 11656 12 146,0 24,3 131,7 26,4 102,9 30,6 88,4 32,7 73,9 34,8 68,0 35,6 45 19815 32 155,0 26,1 139,8 28,0 109,2 31,9 93,8 33,8 78,3 35,7 72,1 36,5 50 5245 3 136,6 22,4 124,5 25,0 100,2 30,1 87,9 32,6 75,5 35,1 70,6 36,1 50 11656 12 161,2 27,3 146,9 29,4 118,0 33,7 103,5 35,7 88,9 37,8 83,1 38,7 50 19815 31 170,9 29,3 155,7 31,2 125,1 35,1 109,7 37,0 94,2 38,9 88,0 39,6 60 5990 4 168,7 28,8 156,1 31,3 130,8 36,2 118,0 38,7 105,1 41,1 100,0 42,0 60 7987 6 180,0 31,1 166,5 33,4 139,4 38,0 125,8 40,2 112,1 42,5 106,6 43,4 60 13312 15 194,9 34,1 180,3 36,2 150,9 40,3 136,1 42,3 121,3 44,3 115,3 45,1 70 5990 4 196,0 34,3 183,3 36,8 157,9 41,7 145,1 44,1 132,2 46,5 127,1 47,5 70 7987 6 208,9 36,9 195,5 39,2 168,3 43,7 154,6 46,0 140,9 48,2 135,4 49,1 70 13312 14 226,0 40,3 211,4 42,4 182,0 46,5 167,2 48,5 152,0 50,5 146,3 51,3

UTNA 130 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 7299 6 146,5 24,4 130,5 26,2 98,3 29,7 82,1 31,5 65,8 33,2 59,3 33,9 40 16221 24 166,2 28,3 148,0 29,7 111,4 32,3 92,9 33,6 74,5 34,9 67,1 35,4 40 27576 62 173,3 29,7 154,3 30,9 116,0 33,3 96,8 34,4 77,6 35,6 69,9 36,0 45 7299 6 163,4 27,8 147,4 29,6 115,1 33,1 98,9 34,8 82,6 36,6 76,0 37,2 45 16221 23 185,2 32,1 166,9 33,5 130,3 36,1 111,8 37,4 93,3 38,7 85,9 39,2 45 27576 60 193,0 33,7 173,9 34,9 135,6 37,2 116,4 38,3 97,2 39,5 89,4 39,9 50 7299 6 180,4 31,2 164,4 33,0 132,1 36,5 115,8 38,2 99,4 39,9 92,9 40,6 50 16221 23 204,2 35,9 186,0 37,3 149,2 39,9 130,8 41,2 112,3 42,5 104,8 43,0 50 27576 59 212,7 37,6 193,6 38,8 155,3 41,1 136,1 42,3 116,8 43,4 109,1 43,9 60 7430 6 215,5 38,2 199,3 40,0 166,7 43,4 150,3 45,1 133,9 46,8 127,3 47,5 60 9907 9 227,7 40,6 210,5 42,2 176,0 45,3 158,7 46,8 141,3 48,3 134,3 48,9 60 16512 23 242,9 43,7 224,5 45,0 187,6 47,6 169,1 48,9 150,5 50,2 143,1 50,7 70 7430 5 250,0 45,1 233,8 46,9 201,1 50,3 184,7 52,0 168,2 53,7 161,6 54,4 70 9907 9 264,0 47,9 246,8 49,5 212,2 52,5 194,9 54,1 177,4 55,6 170,4 56,2 70 16512 22 281,3 51,4 262,9 52,7 226,0 55,3 207,5 56,6 188,9 57,9 181,4 58,4

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 14.300

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit.

Page 26: K11142 ed.5 UTNA GB

26

UTNA 150 performance Cooling capacity

UTNA 150 BA 4R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 5967 3 51,7 51,7 15,0 82 58,7 55,7 16,3 83 62,9 57,4 17,0 83 67,2 59,1 17,7 83 85,3 65,6 20,6 83 104,7 71,1 23,7 83 5 13260 14 70,7 60,5 13,5 83 82,7 65,4 14,6 83 88,9 67,8 15,2 83 95,3 70,2 15,8 83 122,6 78,9 18,3 84 152,8 86,7 20,9 84 5 22542 37 80,9 65,1 12,7 83 94,8 70,7 13,7 83 102,1 73,5 14,2 83 109,6 76,2 14,8 83 141,8 86,5 17,0 84 178,0 95,8 19,4 85 6 5967 3 49,1 49,1 15,5 80 54,4 54,0 16,6 83 58,6 55,8 17,3 83 62,9 57,5 18,0 83 80,8 64,0 20,9 83 100,0 69,7 23,9 83 6 13260 14 65,0 58,0 13,9 83 76,9 63,0 15,1 83 83,1 65,4 15,6 83 89,4 67,8 16,2 83 116,5 76,7 18,7 83 146,5 84,5 21,3 84 6 22542 37 74,5 62,2 13,2 83 88,3 67,9 14,2 83 95,5 70,6 14,7 83 103,0 73,4 15,3 83 134,9 83,7 17,5 84 170,8 93,1 19,8 84 7 5967 3 46,4 46,4 15,9 77 52,0 52,0 17,0 82 54,3 54,2 17,6 83 58,5 55,9 18,3 83 76,3 62,5 21,1 83 95,4 68,3 24,1 83 7 13260 14 59,2 55,5 14,3 83 71,0 60,6 15,5 83 77,1 63,0 16,1 83 83,4 65,4 16,6 83 110,3 74,3 19,1 83 140,0 82,3 21,7 84 7 22542 37 67,9 59,3 13,7 83 81,7 65,0 14,7 83 88,9 67,8 15,2 83 96,2 70,6 15,7 83 128,0 81,0 17,9 84 163,6 90,5 20,3 84 8 5967 3 43,8 43,8 16,4 75 49,3 49,3 17,4 79 52,1 52,1 17,9 82 54,9 54,9 18,5 84 71,7 61,1 21,4 83 90,6 66,9 24,4 83 8 13260 14 53,3 53,1 14,8 83 65,0 58,2 15,9 83 71,1 60,6 16,5 83 77,4 63,0 17,0 83 104,0 72,1 19,5 83 133,5 80,2 22,1 84 8 22542 36 61,3 56,4 14,2 83 74,9 62,2 15,2 83 82,1 65,0 15,7 83 89,4 67,8 16,2 83 120,9 78,3 18,4 84 156,3 87,9 20,7 84 9 5967 3 41,1 41,1 16,9 73 46,7 46,7 17,9 77 49,5 49,5 18,4 79 52,3 52,3 18,9 81 67,1 59,6 21,6 83 85,9 65,6 24,6 83 9 13260 14 49,2 49,2 15,5 80 59,0 55,8 16,3 83 65,0 58,3 16,9 83 71,2 60,7 17,5 83 97,6 69,8 19,9 83 126,9 78,0 22,4 84 9 22542 36 54,5 53,6 14,7 83 68,1 59,4 15,7 83 75,1 62,2 16,2 83 82,4 65,0 16,7 83 113,7 75,6 18,9 83 148,8 85,3 21,2 84

10 5967 3 38,4 38,4 17,3 71 44,0 44,0 18,4 75 46,8 46,8 18,9 77 49,6 49,6 19,4 79 62,5 58,1 21,9 83 81,2 64,2 24,8 83 10 13260 14 45,9 45,9 16,0 77 52,6 52,6 16,9 82 58,9 55,9 17,3 83 65,0 58,3 17,9 83 91,2 67,6 20,3 83 120,2 75,9 22,8 83 10 22542 36 49,1 49,1 15,5 80 61,1 56,6 16,2 83 68,1 59,4 16,7 83 75,3 62,2 17,2 83 106,3 72,9 19,3 83 141,2 82,7 21,6 84

UTNA 150 BA 6R

Tai: 24°C / 47% UR Tai: 26°C / 47% UR Tai: 27°C / 47% UR Tai: 28°C / 47% UR Tai: 32°C / 47% UR Tai: 36°C / 47% UR Twi G Δpw QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR QT QS Tau UR °C l/h kPa kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % kW kW °C % 5 8350 7 73,4 66,4 12,5 91 85,4 71,5 13,6 91 91,6 73,9 14,2 91 97,9 76,3 14,7 91 124,4 84,9 17,2 92 153,0 92,4 20,0 92 5 18555 28 98,4 77,6 10,5 91 115,3 84,4 11,3 91 124,1 87,8 11,8 92 133,2 91,0 12,2 92 172,3 103,5 14,0 92 216,0 114,8 16,1 93 5 31544 74 109,1 82,6 9,7 91 128,2 90,3 10,3 92 138,2 94,1 10,6 92 148,5 97,9 11,0 92 193,1 112,5 12,5 93 243,8 126,0 14,1 94 6 8350 7 67,3 63,9 12,9 91 79,2 69,0 14,0 91 85,3 71,5 14,6 91 91,6 73,8 15,2 91 117,9 82,6 17,6 92 146,3 90,1 20,3 92 6 18555 28 90,5 74,0 11,1 91 107,3 80,9 12,0 91 116,1 84,3 12,4 92 125,1 87,5 12,8 92 163,8 100,1 14,6 92 207,2 111,5 16,6 93 6 31544 73 100,5 78,6 10,3 91 119,5 86,3 11,0 92 129,4 90,2 11,3 92 139,7 93,9 11,7 92 184,0 108,5 13,2 93 234,4 122,1 14,8 93 7 8350 7 62,2 62,2 13,2 92 73,0 66,5 14,4 91 79,1 68,9 15,0 91 85,3 71,4 15,6 91 111,3 80,2 18,1 91 139,5 88,0 20,7 92 7 18555 28 82,5 70,4 11,8 91 99,2 77,4 12,6 91 108,0 80,7 13,0 91 116,9 84,0 13,4 92 155,3 96,6 15,2 92 198,3 108,1 17,2 92 7 31544 73 91,8 74,6 11,0 91 110,7 82,4 11,7 92 120,5 86,2 12,0 92 130,7 90,0 12,4 92 174,7 104,5 13,8 92 224,7 118,2 15,5 93 8 8350 7 58,6 58,6 13,8 89 66,7 64,0 14,9 91 72,7 66,5 15,4 91 78,9 68,9 16,0 91 104,7 78,0 18,5 91 132,6 85,8 21,1 92 8 18555 28 74,4 66,9 12,4 91 91,0 73,8 13,2 91 99,6 77,3 13,6 91 108,5 80,6 14,0 92 146,6 93,2 15,8 92 189,2 104,8 17,8 92 8 31544 73 83,0 70,6 11,7 91 101,7 78,4 12,4 91 111,5 82,2 12,7 91 121,6 86,0 13,1 92 165,3 100,6 14,5 92 214,9 114,4 16,1 93 9 8350 7 55,0 55,0 14,4 85 62,4 62,4 15,2 92 66,3 64,1 15,9 91 72,4 66,6 16,4 91 98,1 75,7 18,8 91 125,7 83,7 21,5 92 9 18555 28 66,2 63,4 13,0 91 82,6 70,4 13,8 91 91,2 73,8 14,2 91 100,0 77,1 14,6 91 137,8 89,9 16,4 92 180,1 101,5 18,4 92 9 31544 72 73,9 66,7 12,4 91 92,5 74,5 13,1 91 102,2 78,3 13,4 91 112,2 82,1 13,7 92 155,6 96,8 15,2 92 204,8 110,6 16,8 93

10 8350 7 51,4 51,4 15,1 82 58,8 58,8 15,8 88 62,6 62,6 16,1 91 66,0 64,2 16,9 91 91,4 73,5 19,2 91 118,8 81,6 21,8 92 10 18555 28 58,8 58,8 13,8 89 74,1 67,0 14,4 91 82,6 70,4 14,8 91 91,4 73,8 15,2 91 128,8 86,6 17,0 92 170,8 98,3 18,9 92 10 31544 72 64,7 62,8 13,1 91 83,1 70,6 13,7 91 92,8 74,4 14,1 91 102,7 78,3 14,4 91 145,8 92,9 15,9 92 194,6 106,8 17,5 92

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature UR = Relative humidity QT = Cooling capacity (total heat) QS = Cooling capacity (sensibleheat) Tau = Air outlet temperature

Capacity correction factors The given capacities refer to the following conditi ons:

Air flow m3/h 16.500

with a 4 row coil (BA4R) and filter. To calculate the capacities at the other speeds, please use the following correction factors:

UTNA 150

Air flow m3/h 8000 11000 16500 Capacity correction factor 0,64 0,79 1,00

Page 27: K11142 ed.5 UTNA GB

27

UTNA 150 performance Heating capacity

UTNA 150 BA 2R / KB 2R auxiliary coil

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 50 4162 2 94,2 11,4 86,0 14,9 69,3 22,0 60,9 25,6 52,3 29,1 48,9 30,5 50 5549 3 102,0 12,7 93,0 16,2 75,0 23,0 65,8 26,4 56,6 29,8 52,9 31,2 50 9249 7 113,0 14,6 103,1 17,9 83,0 24,4 72,9 27,7 62,7 30,9 58,6 32,2 60 4162 2 112,5 14,5 104,2 18,1 87,5 25,2 79,0 28,7 70,4 32,2 67,0 33,6 60 5549 3 121,6 16,1 112,6 19,6 94,5 26,4 85,3 29,8 76,1 33,2 72,4 34,6 60 9249 7 134,5 18,4 124,6 21,6 104,5 28,2 94,4 31,4 84,1 34,6 80,0 35,9 70 4162 2 130,9 17,7 122,6 21,3 105,8 28,4 97,3 31,9 88,8 35,4 85,3 36,8 70 5549 3 141,4 19,6 132,4 23,0 114,3 29,9 105,1 33,3 95,8 36,6 92,1 38,0 70 9249 7 156,2 22,1 146,2 25,4 126,2 31,9 116,0 35,2 106,0 38,4 101,7 39,7

UTNA 150 BA 4R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 5967 3 126,1 16,9 112,4 19,5 84,8 24,7 70,9 27,3 56,9 29,9 51,3 30,9 40 13260 12 149,6 21,0 133,3 23,2 100,4 27,5 83,9 29,6 67,3 31,7 60,6 32,5 40 22542 32 159,0 22,6 141,7 24,6 106,7 28,5 89,1 30,5 71,4 32,4 64,4 33,2 45 5967 3 140,8 19,5 127,2 22,1 99,5 27,3 85,5 29,9 71,5 32,4 65,8 33,4 45 13260 12 166,8 24,0 150,5 26,1 117,6 30,4 101,0 32,6 84,4 34,7 77,7 35,5 45 22542 31 177,2 25,8 159,8 27,8 124,8 31,7 107,2 33,6 89,6 35,6 82,5 36,3 50 5967 3 155,7 22,0 142,0 24,7 114,2 29,8 100,2 32,4 86,1 35,0 80,5 36,0 50 13260 12 184,1 27,0 167,8 29,2 134,9 33,4 118,3 35,5 101,6 37,7 94,9 38,5 50 22542 31 195,4 29,0 178,0 30,9 143,0 34,9 125,4 36,8 107,7 38,7 100,6 39,5 60 6852 4 192,7 28,5 178,4 31,0 149,4 36,0 134,8 38,4 120,1 40,9 114,2 41,8 60 9136 6 205,7 30,7 190,3 33,1 159,4 37,7 143,8 40,0 128,1 42,3 121,8 43,2 60 15226 15 222,9 33,7 206,2 35,8 172,6 40,0 155,7 42,0 138,7 44,1 131,9 44,9 70 6852 3 223,9 33,9 209,5 36,4 180,4 41,3 165,8 43,8 151,1 46,2 145,2 47,2 70 9136 6 238,8 36,5 223,4 38,8 192,4 43,4 176,7 45,7 161,0 48,0 154,7 48,9 70 15226 14 258,5 39,9 241,8 42,0 208,1 46,2 191,2 48,2 174,0 50,3 167,3 51,1

UTNA 150 BA 6R

Tai: -5°C Tai: 0°C Tai: 10°C Tai: 15°C Tai: 20°C Tai: 22°C Twi G �pw Q Tau Q Tau Q Tau Twi G �pw Q Tau Q °C l/h kPa kW °C kW °C kW °C °C l/h kPa kW °C kW 40 8350 6 167,7 24,1 149,5 26,0 112,6 29,6 94,0 31,3 75,4 33,1 67,9 33,8 40 18555 25 190,6 28,1 169,7 29,5 127,7 32,2 106,6 33,5 85,4 34,8 76,9 35,4 40 31544 63 198,8 29,5 176,9 30,7 133,1 33,1 111,1 34,3 89,0 35,5 80,1 35,9 45 8350 6 187,2 27,5 168,8 29,3 131,9 32,9 113,3 34,7 94,6 36,4 87,1 37,1 45 18555 24 212,3 31,9 191,4 33,3 149,3 35,9 128,2 37,3 107,0 38,6 98,5 39,1 45 31544 62 221,3 33,5 199,5 34,7 155,6 37,0 133,6 38,2 111,5 39,4 102,6 39,8 50 8350 6 206,7 30,9 188,3 32,7 151,3 36,3 132,6 38,0 113,9 39,8 106,4 40,5 50 18555 24 234,1 35,7 213,2 37,0 171,1 39,7 149,9 41,0 128,7 42,4 120,2 42,9 50 31544 61 243,9 37,4 222,1 38,6 178,2 41,0 156,1 42,1 134,0 43,3 125,1 43,7 60 8523 6 247,0 37,9 228,4 39,7 191,1 43,2 172,3 44,9 153,4 46,7 145,9 47,3 60 11363 10 261,0 40,3 241,4 41,9 201,8 45,1 181,9 46,6 162,0 48,1 154,0 48,8 60 18939 24 278,5 43,4 257,5 44,7 215,2 47,4 194,0 48,7 172,7 50,0 164,1 50,5 70 8523 6 286,5 44,8 267,9 46,6 230,5 50,0 211,7 51,8 192,8 53,5 185,2 54,2 70 11363 9 302,6 47,6 282,9 49,2 243,3 52,3 223,4 53,8 203,4 55,3 195,4 55,9 70 18939 23 322,6 51,1 301,6 52,4 259,2 55,0 238,0 56,3 216,7 57,6 208,1 58,2

Twi = Water inlet temperature G = Water f low rate Δpw = Pressure drop water side Tai = Air inlet temperature Q = Heating capacity Tau = Air outlet temperature

NB The given capacities refer to the following conditi ons:

Air flow m3/h 16.500

with a 4 row coil (BA4R) and standard filter. To calculate the yields at the other speeds, please use the correction fac tors on the precedi ng page. Due to the high outlet air temperatur e,

these values require an i nspection of the electric motor fit ted on the unit

Page 28: K11142 ed.5 UTNA GB

28

UTNA Available E.S.P.

UTNA 015 SV

UTNA 020 SV

UTNA 029 SV

030

6090

120150180210

240270

300330

1200 1500 1800 2100 2400 2700 3000 3300portata aria

pre

vale

nza

util

e

Pa

m3/h3220

(1)(1)(1)

0306090

120150180210240270300330

1200 1500 1800 2100 2400 2700 3000portata aria

pre

vale

nza

utile

Pa

m3/h

2640

NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e A Calculation example ○ 6 row cooling coil (BA6R) + additi onal heating coil (KB2R). ○ Required air flow: 3000 m3/h. ○ Required available E.S.P.: 120 Pa. ○ According to the UTNA 029 SV diagram, a four row coil (BA4R) and standar d filter gives an ESP equal to 170 Pa at maximum speed with an air flow rate equal to 3,000 m3/h. ○ Table A for model UTNA 029 gives the followi ng values for the required air flow rate equal to 3,000 m3/h:

• BA6R: -20 Pa ; • KB2R: -18 Pa;

○ The residual ESP is therefore equal to: 170 + (-20) + (-18) = 132 Pa.

(1) = Minimum pressure drops allowed to avoi d overloadi ng the electric motor.

0

30

60

90

120

150

180

210

240

600 900 1200 1500 1800 2100portata aria

prev

alen

za u

tile

Pa

m3/h1800

NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e A

NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e A

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Page 29: K11142 ed.5 UTNA GB

29

UTNA prevalenza utile

UTNA 038 SV

UTNA 051 SV

Table A - Variation in available E.S.P. for BA2R, BA6R, KB2R.

Model Module Air flow m3/h

1200 1500 1800 2100 2400 2640 3000 3220 3300 3600 3900 4260 4500 5100 5700 6120

BA2R 16 25 33 48 BA4R 0 0 0 0 BA6R -13 -20 -27 - KB2R -10 -15 -21 -29

UTNA 015

SIL

∆ Available E.S.P. Pa

-2 -3 -4 -5 BA2R 35 52 50 54 BA4R 0 0 0 0 BA6R -27 -39 -45 - KB2R -19 -25 -33 -40

UTNA 020

SIL

∆ Available E.S.P. Pa -3 -5 -6 -7

BA2R 17 21 21 32 36 BA4R 0 0 0 0 0 BA6R -14 -17 -20 -26 -29 KB2R -12 -14 -18 -21 -22

UTNA 029

SIL

∆ Available E.S.P. Pa

-2 -2 -3 -3 -4 BA2R 20 22 23 28 30 40 BA4R 0 0 0 0 0 0 BA6R -16 -19 -20 -24 -27 - KB2R -13 -15 -16 -19 -22 -27

UTNA 038

SIL

∆ Available E.S.P. Pa

-3 -3 -3 -4 -4 -5 BA2R 24 27 35 44 49 BA4R 0 0 0 0 0 BA6R -20 -23 -29 -37 -45 KB2R -16 -18 -23 -29 -34

UTNA 051

SIL

∆ Available E.S.P. Pa

-6 -7 -9 -11 -13

0

4590

135180

225

270315

360405

450

3000 3600 4200 4800 5400 6000 6600portata aria

prev

alen

za u

tile

Pa

m3/h6120

(1)

(1)

portata aria m3/h

portata aria m3/h

03060

90120150180210240270300330

2400 2700 3000 3300 3600 3900 4200 4500portata aria

prev

alen

za u

tile

Pa

m3/h4260

(1) = Minimum pressure drops allowed to avoi d overloadi ng the electric motor.

NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e A

NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e A

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Page 30: K11142 ed.5 UTNA GB

30

UTNA Available E.S.P. UTNA 078 SV (1) Maxi mum number of fan r evoluti ons

allowed by the variable belt pulley = 702 rpm. (2) Minimum number of fan revolutions allowed by the variable belt pulley = 598 rpm. • The belt pulley leaves the factor y calibrated to 642 rpm. (3) Power limit of installed motor. (4) Fan wor king range. NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e B.

UTNA 107 SV

(1) Maxi mum number of fan r evoluti ons allowed by the variable belt pulley = 565 rpm. (2) Minimum number of fan revolutions allowed by the variable belt pulley = 486 rpm. • The belt pulley leaves the factor y calibrated to 492 rpm. (3) Power limit of installed motor. (4) Fan wor king range. NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e B.

UTNA 130 SV

(1) Maxi mum number of fan r evoluti ons allowed by the variable belt pulley = 598 rpm. (2) Minimum number of fan revolutions allowed by the variable belt pulley = 509 rpm. • The belt pulley leaves the factor y calibrated to 547 rpm. (3) Power limit of installed motor. (4) Fan wor king range. NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e B.

Air flow rate m3/h

0

50

100

150

200

250

4000 5000 6000 7000 8000 9000 10000 Air flow rate m3/h

8580

(1)

(2) (3)

(4)

Ava

ilabl

e E.

S.P.

Pa

50

100

150

200

250

5500 6500 7500 8500 9500 10500 11500 12500por tata aria (m3/h)

prev

alen

za u

tile

(Pa)

(1)

(2)

(3)

11.770

(4)

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Pa

0

50

100

150

200

250

7000 8000 9000 10000 11000 12000 13000 14000 15000portata aria (m3/h)

prev

alen

za u

tile

(Pa)

(1)

(2) (3)

14.300

(4)

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Pa

Page 31: K11142 ed.5 UTNA GB

31

UTNA Available E.S.P

UTNA 150 SV

(1) Maxi mum number of fan r evoluti ons allowed by the variable belt pulley = 718 rpm. (2) Minimum number of fan revolutions allowed by the variable belt pulley = 610 rpm. • The belt pulley leaves the factor y calibrated to 656 rpm. (3) Power limit of ins talled motor. (4) Fan wor king range. NB ○ The cur ve in the diagram shows the availabl e ESP with a 4 row coil (BA 4R) and filter. ○ For different configurati ons, add the values indicated in Tabl e B.

Table B – Variation in available E.S.P. for BA2R, BA6R, KB2R Model UTNA 078 UTNA 107 UTNA 130 UTNA 150 Module Air flow rate

m3/h 4.300 5.700 8.580 5.900 7.800 11.770 7.100 9.500 14.300 8.000 11.000 16.500

BA2R Δpu Pa 11 19 44 9 15 34 12 21 48 12 22 50 BA4R Δpu Pa 0 0 0 0 0 0 0 0 0 0 0 0 BA6R Δpu Pa -9 -16 -36 -7 -13 -29 -9 -17 -38 -9 -18 -40 KB2R Δpu Pa -7 -12 -27 -6 -10 -22 -7 -13 -30 -7 -14 -31 SIL Δpu Pa -2 -3 -7 -3 -6 -13 -2 -4 -8 -3 -5 -12 ∆pu = Variation in available E.S.P.

0

50

100

150

200

250

8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000portata aria (m3/h)

prev

alen

za u

tile

(Pa)

(1)

(2)(3)

16.500

(4)

Air flow rate m3/h

Ava

ilabl

e E.

S.P.

Pa

Page 32: K11142 ed.5 UTNA GB

32

UTNA SV fan module

UTNA 015-020-029-038-051

a l

ig

h

c

b

d e f

1

3

2

UTNA 078-107-130

○ UTNA is designed for ceiling installati on and therefore must be assembled in a horizontal position. ○ UTNA features two base sections: the SV fan modul e and the BA coil module ○ The SV fan module includes a centrifugal fan with an IP55 protection index. ○ Models 051-078-107-130- 150 are factory fitted with a control board (IP55). ○ An accessor y control board (KQE) with a power terminal board housed in a sealed box (IP55) for assembly inside the SV fan modul e is availabl e for models 015-020-029-038. ○ On request the SV fan modul e on units 078-107-130-150 can be supplied with a three phase 4/6 or 4/8 pole motor

UTNA 150

1. Fan 2. Power suppl y 3. Control board (factory fitted on models

051÷150, accessor y on models 015÷038)

4. Elec tric motor SV Module 015 020 029 038 051 078 107 130 150 a mm 370 370 435 490 490 1040 1040 1040 1040 b mm 928 928 1228 1228 1328 1658 2058 2058 2058 c mm 398 398 463 518 568 768 918 918 1018 d mm 348 315 465 465 498,5 593,5 750,5 750.,5 384 e mm 232 298 298 298 331 471 557 557 417 f mm 348 315 465 465 498,5 593,5 750,5 750,5 366 g mm 208 262 262 262 289 404 478 478 404 h mm 127 73,5 137 144 166 96 107 107 372 i mm 63 62,5 64 112 113 - - - - l mm 10 4 10 1 9 268 333 333 242 weight SV kg 28 34 46 54 66 180 200 204 212 weight 4/8 pole SV kg - - - - - 182 202 211 230 weight 4/6 pole SV kg - - - - - 185 205 209 227

SV

BA

Page 33: K11142 ed.5 UTNA GB

33

UTNA BA coil module

UTNA 015÷150 BA coil module with additional heating coil (KB2R accessory)

○ UTNA is designed for ceiling installati on and therefore must be assembled in a horizontal position. ○ UTNA is made up of two base sections: the SV fan module and BA coil modul e ○ BA module i ncludes filter and water filled heta exchanging coil; it can be compl eted with an additi onal water filled heating coil (KB2R accessor y) or, i n alternative, with an additional heating electrical heater (KR accessory) or with a droplet eliminator (KSG accessor y) on models 078-107-130-150.

BA coil module with additional electrical heater (KR accessory)

○ The BA module is supplied factory fitted with right hand coil connections (according to the air flow direction). However, it is possible to rotate the coil so the connections are on the left ○ The filter is made of pleated synthetic fibres with a G3 efficiency index, it consists in 2 cells which can be extracted from any direction. ○ The condensate drain pan features gravity feed.

1. Reusabl e filter 5. Condensate drain pan (4R and 6R onl y) 9. Additional coil water outl et 2. 2R, 4R, 6R standard coil 6. Additional coil water inl et 10. Water outlet 3. Water inlet 7. Droplet eli minator (KSG accessor y) 11 Additi onal electrical heater (KR accessory) 4. Condensate discharge 8. Additional heating coil (acc. KB 2R) 12. Control board (QE)

Module BA 015 020 029 038 051 078 107 130 150 a mm 645 645 645 645 645 910 910 910 910 b mm 928 928 1228 1228 1328 1658 2058 2058 2058 c mm 398 398 463 518 568 768 918 918 1018 d mm 155 155 155 155 155 170 170 170 170 e mm 270 270 270 270 270 440 440 440 440 f mm 220 220 220 220 220 300 300 300 300 g mm 203 203 203 203 203 248 248 248 248 h mm 86,5 86,5 86,5 86,5 86,5 86,5 86,5 86,5 86,5 i mm 400 400 400 400 400 540 540 540 540 l mm 510 510 510 510 510 749 749 749 749 m mm 86,5 86,5 86,5 86,5 86,5 86,5 86,5 86,5 86,5 n mm 190 190 255 300 340 542 692 692 792 o mm 104 104 104 109 114 113 113 113 113 p 2R/4R/6R mm 50 / 50 / 50 50 / 50 / 50 50 / 65 / 65 50 / 65 / 65 65 / 65 / 65 69 / 69 /89 69 / 89 /89 69 / 89 / 89 69 / 89 / 89 ∅a 2R/4R/6R G ¾ / ¾ / ¾ ¾ / ¾ / ¾ ¾ / 1 / 1 1 / 1¼ / 1¼ 1 / 1¼ / 1¼ 11/4 / 11/2 /2 11/2 / 2 / 2 11/2 / 2 / 2 11/2 / 2 / 2 ∅b G ¾ ¾ ¾ 1 1 1 1/4 1 1/2 1 1/2 1 1/2 ∅c mm 25 25 25 25 25 28 28 28 28 q mm 167,5 167,5 188 188 188 188 188 188 188 r mm 200 200 236 236 236 236 236 236 236 s mm 210 210 228 228 228 268 268 268 268 t mm 39,5 39,5 41,5 41,5 56,5 101 101 101 101 u mm 254 254 316 316 316 316 316 316 316 Weight BA Weight BA2R kg 45 45 58 60 65 105 145 145 156 Weight BA4R kg 48 48 63 66 73 121 177 177 193 Weight BA6R kg 51 51 68 71 79 140 200 200 220 Weight of water filled and completely accessoried BA Weight BA2R kg 63,1 66,1 85,9 89,3 106,8 167,1 225 225 240 Weight BA4R kg 67,2 70,2 92,9 97,5 117,6 188,2 265,1 265,1 286,1 Weight BA6R kg 71,3 74,3 99,9 104,8 126,4 212,3 296,1 296,1 322,1

SV

BA

Page 34: K11142 ed.5 UTNA GB

34

UTNA modules and accessories

KSG - Droplet eliminator

○ Droplet eli minator in plastic, i ncluded in BA module for models 078-150 only.

KSG 078 107 130 150 a mm 100 100 100 100 b mm 1440 1840 1840 1840 c mm 680 830 830 930 Weight kg 15 21 21 23

KB 2R – Additional water filled heating coil

○ The additi onal water filled heating coil is with 2 rows, copper pipes and aluminium fins

○ The additi onal coil KB 2R is forseen to be inserted in the BA modul e.

KB 2R 015 020 029 038 051 078 107 130 150 a mm 160 160 160 160 160 160 160 160 160 b mm 950 950 1250 1250 1365 1665 2065 2065 2065 c mm 315 315 390 440 490 680 830 830 930 Weight kg 9 9 12 13 17 24 34 34 38

SV

BA

Page 35: K11142 ed.5 UTNA GB

35

UTNA modules and accessories

KR: additional electrical heater

○ KR electrical heater has got armoured car bon steel resistors with zinc s teel fins and is completed with control board with magnetother mic switch, safety thermostats, power contactors and user termi nal board. ○ KR electrical heater is availabl e for all models with three-phase supply and for models 015-020-029-038 also with single phase suppl y. For each models there are till 3 power sizes. ○ KR electrical heater is completed with automatic recocked and manual safety thermostats; both ar e fitted i nside the control board. ○ KR electrical heater is forseen to be fitted in BA module i n place of KB2R additional water heating coil. .

Available power Model Electrical heater KR UTNA Power suppl y 230V - 1 ph – 50Hz Technical data 015 Power/Step kW / n. 1,5 / 1 3,0 / 1 4,5 / 1 020 Power/Step kW / n. - 3,0 / 1 4,5 / 1 6,0 / 1

029 Power/Step kW / n. - - 4,5 / 1 6,0 / 1 9,0 / 1

038 Power/Step kW / n. - - - 6,0 / 1 9,0 / 1 12,0 / 2 Absorbed current 230V-1ph A 6,5 13 19,6 26,1 39,1 52,2 Electrical line section mm2 2,5 4 6 10 16 25

Model Electrical heater KR UTNA Power suppl y 400V - 3 ph – 50Hz Technical data 015 Power/Step kW / n. 1,5 / 1 3,0 / 1 4,5 / 1 020 Power/Step kW / n. - 3,0 / 1 4,5 / 1 6,0 / 1

029 Power/Step kW / n. - - 4,5 / 1 6,0 / 1 9,0 / 1

038 Power/Step kW / n. - - - 6,0 / 1 9,0 / 1 12,0 / 2

051 Power/Step kW / n. - - - - 9,0 12,0 / 2 18,0 / 2

078 Power/Step kW / n. - - - - - 12,0 / 2 18,0 / 2 24,0 / 2

107 Power/Step kW / n. - - - - - - 18,0 / 2 24,0 / 2 36,0 / 2 130 Power/Step kW / n. - - - - - - 18,0 / 2 24,0 / 2 36,0 / 2 150 Power/Step kW / n. - - - - - - - 24,0 / 2 36,0 / 2 Absorbed current 400V-3ph A 2,2 4,3 6,5 8,7 13 17,3 26 34,6 52 Electrical line section mm2 2,5 2,5 2,5 2,5 4 6 10 16 25

Thermal stage at the nominal flow Model UTNA 015 020 029 038 051 078 107 130 150 Electrical heater power KR

Nominal flow m3/h 1.800 2.640 3.220 4.260 6.120 8.580 11.770 14.300 16.500

1,5 kW Δt °C 2,5 3,0 kW Δt °C 4,9 3,4 4,5 kW Δt °C 7,4 6,4 4,2 6,0 kW Δt °C 8,5 5,5 4,2 9,0 kW Δt °C 8,3 6,3 4,4 12,0 kW Δt °C 8,4 5,8 4,2 18,0 kW Δt °C 8,7 6,2 4,5 3,7 24,0 kW Δt °C 8,3 6,1 5 4,3 36,0 kW Δt °C 9,1 7,5 6,5

Δt °C = Handled air’s ther mal stage. N. B. Using accessor y KR electrical heater to integrate the main coil, avoi d any el ectrical powers, which

can lead to outl et air temperatures up to 50° .. Dimensions

KR Model UTNA 015 020 029 038 051 078 107 130 150 1,5-3,0-4,5 kW a x b x c mm 235x1105x375 3,0-4,5-6,0 kW a x b x c mm 235x1105x375 4,5-6,0-9,0 kW a x b x c mm 235x1425x440 6,0-9,0-12,0 kW a x b x c mm 235x1425x495

9,0-12,0-18,0 kW a x b x c mm 235x1525x550 12,0-18,0-24,0 kW a x b x c mm 300x1800x740 18,0-24,0-36,0 kW a x b x c mm 300x2200x890 300x2200x890

24,0-36,0 kW a x b x c mm 300x2200x990 Peso Kg 17 20 26 27 39 42 51 51 52

SV

BA

Page 36: K11142 ed.5 UTNA GB

36

UTNA modules and accessories

PMA – INTAKE/DELIVERY PLENUM

○ The PMA module functi ons as an intake/deli ver y plenum. When used as an intake plenum, it is installed upstream of the BA module, whereas when used as a deli ver y plenum, it is installed downstream of the SV module. Ther efore, it can return or deliver air from the front, top or bottom.

○ It can be used with the following accessories: KSER conjugated damper, KPCC blind panel, KPBM delivery spigot and the KPBC panel with circular spigots

○ To obtain bottom or top intake or delivery, move the bottom or top panel on the PMA plenum on the front aperture.

PMA Module 015 020 029 038 051 078 107 130 150 a mm 370 370 435 490 540 740 890 890 990 b mm 928 928 1228 1228 1328 1658 2058 2058 2058 c mm 398 398 463 518 568 768 918 918 1018 weight kg 21 21 30 32 39 69 87 87 94

KSER – Conjugated damper

○ The conjugated damper accessor y is fi xed to the PMA intake plenum or directl y to the BA. ○ The external air flow rate equals 25% of the total. ○ The KSER accessor y can be i nstalled on the bottom or top of the PMA plenum by changing the respective panels.

KCMS Manual control

for the KSER damper

○ The KCMS contr ol allows the conjugated damper to be opened and closed manuall y. ○ It is applied to the damper manoeuvre pin. ○ Weight=0,5 kg.

KSER accessory 015 020 029 038 051 078 107 130 150 a mm 140 140 140 140 140 140 140 140 140 b mm 900 900 1200 1200 1300 1630 2030 2030 2030 c mm 370 370 315 470 520 730 880 880 980 d mm 30 30 30 30 30 110 135 135 135 e mm 310 310 355 410 460 510 610 610 710 f mm 30 30 30 30 30 30 30 30 30 g mm 650 650 890 890 970 1230 1550 1550 1550 h mm 160 160 220 220 240 310 390 390 390 weight kg 9 9 12 13 14 18 23 23 25

PMA

BA SV PMA

1. Fresh air (max 25%)

BA SV

KSER

PMA

Air flow section

Page 37: K11142 ed.5 UTNA GB

37

UTNA modules and accessories

KPCC – Blind panel for the PMA UTNA 015-020-029-038-051

g d g

b

a

fe

f

c PMA

UTNA 078-107-130 - 150

○ The blind panel is fi xed to the PMA intake/deli ver y plenum or directly to the BA; it features knockouts for connection to a duct. ○ The KPCC accessory can also be installed on the top or bottom of the PMA plenum by changing the respecti ve panels.

KPCC accessory 015 020 029 038 051 078 107 130 150 a mm 14 14 14 14 14 14 14 14 14 b mm 918 918 1228 1228 1328 1658 2058 2058 2058 c mm 370 370 435 490 540 740 890 890 990 d mm 601 601 922 922 922 1080 1402 1402 1402 e mm 214 214 306 306 402 515 614 614 702 f mm 78 78 64,5 92 69 112,5 138 138 144 g mm 163,5 163,5 153 153 203 295 334 334 334 g1 mm - - - - - 283 332 322 332 weight kg 3 3 5 5 6 11 16 16 18

BA SV PMA

KPCC

Page 38: K11142 ed.5 UTNA GB

38

UTNA modules and accessories

KPBM – Delivery panel with rectangular spigot UTNA 015-020-029-038-051

b

c

a

PMA

UTNA 078-107-140-150

○ The panel with aluminium rectangular spigot is fixed to the PMA delivery plenum or directl y to the BA. It allows air to be supplied directl y into the r oom through a double row of adjustable louvers.

The KPBM accessory can also be installed on the top or bottom of the PMA plenum by changing the respecti ve panels.

KPAM accessory 015 020 029 038 051 078 107 130 150 a mm 20 20 20 20 20 20 20 20 20 b mm 928 928 1228 1228 1328 1658 2058 2058 2058 c mm 370 370 435 490 540 740 890 890 990 weight kg 5 5 7 8 9 15 20 20 23

Page 39: K11142 ed.5 UTNA GB

39

UTNA modules and accessories

KPBC – Panel with circular spigots UTNA 015-020

ee

c PMA

g f f g

Øa

b d

a

UTNA 029

g f f f g

be

ec

a

d

ØaPMA

UTNA 038

g f f g

b

Øa

h f h

ei

e

c

a

d

PMA

UTNA 051

h

ei

e

c

a

d

PMA

Øa

g f f g

b

h f f f

KPBC accessory 015 - 020 029 038 051 a mm 14 14 14 14 b mm 928 1228 1228 1328 c mm 370 435 490 540 d mm 48 48 48 48 e mm 185 217,5 175 170 f mm 260 260 420 320 g mm 204 224 404 344 h mm - - 194 184 i mm - - 140 200 ∅a mm 204 204 204 204 weight kg 4 6 6 8

KPBC

○ The KPBC panel with circular spigots allows air to be distributed through more than one duct so conditioned air can be supplied to more than one environment. ○ It must be fixed to the PMA intake/supply plenum or, to intake, directl y to the BA. ○ The KPBC accessor y can be installed on the top or bottom of the PMA plenum by changing the respective panels

BA SV PMA

Page 40: K11142 ed.5 UTNA GB

40

UTNA modules and accessories

SIL – PLENUM WITH SILENCER

SIL module 015 020 029 038 051 078 107 130 150 a mm 960 960 960 960 960 1040 1040 1040 1040 b mm 928 928 1228 1228 1328 1658 2058 2058 2058 c mm 398 398 463 518 568 768 918 918 1018 d mm 209 209 114 114 164 329 529 279 279 e mm 500 500 1000 1000 1000 1000 1000 1500 1500 f mm 99 99 131,5 159 184 184 259 259 309 g mm 200 200 200 200 200 400 400 400 400 weight kg 50 50 63 66 71 108 126 130 134

Noise pressure reduction ○ The plenum with silencer reduces the noise level of the air flow

SIL Module Noise reduction dB(A) 11,4

Possible installations ○ The SIL accessory can be installed up or downstream of the SV fan or i n both positi ons as indicated i n the figure. ○ The SIL module should be positioned so that it conveys the air flow towards to BA+SV modules as indicated in the figure.

BA SV SIL

BA SV SIL

BA SV SIL SIL

BA SV SIL

Page 41: K11142 ed.5 UTNA GB

41

UTNA modules and accessories

STEAM HUMIDIFIER

MUV – Plenum with steam humidifier

MUV module 015 020 029 038 051 078 107 130 150 a mm 960 960 960 960 960 1040 1040 1040 1040 b mm 928 928 1228 1228 1328 1658 2058 2058 2058 c mm 398 398 463 518 568 768 918 918 1018 d mm 78 78 78 78 78 78 78 78 78 e mm 100 100 104 104 104 110 110 110 110 f mm 240 240 240 240 240 160 160 160 160 g mm - - - - - - - 200 200 h mm 480 480 480 480 480 520 520 520 520 distributor pipe n. 1 1 1 1 1 1 1 2 2 weight kg 35 35 41 42 45 74 86 90 97

PRV – External steam producer featuring immersed electrodes

○ The MUV plenum and the PRV producer are connected by the steam feed pipe and the condensate collection pipe supplied. ○ The length of the steam feed pipe must not exceed the value indicated i n the table. ○ Make sure there is sufficient space available before installing the steam producer on the wall and obser ve the clearances indicated in the figure ○ In the models 015/038 for the use of PRV steam pr oducer buying the control board is preferable. For the other models the control board is standard delivered.

PRV module 015 020 029 038 051 078 107 130 150 Technical data Maximum steam production kg/h 3,0 3,0 5,0 5,0 10,0 15,0 15,0 25,0 25,0 Power input kW 2,25 2,25 3,75 3,75 7,50 11,25 11,25 18,75 18,75

230-1- 50 - - - - - Power supply V-ph-Hz 400-3- 50 Absorbed current 230V-1ph A 9,8 9,8 16,3 16,3 - - - - - Absorbed current 400V-3ph A 3,2 3,2 5,4 5,4 10,8 16,2 16,2 27,1 27,1 Dimensions and weights Steam feed pipe and condensate discharge pipe length

m 3,0 3,0 4,0 4,0 4,0 4,0 4,0 4,0 4,0

A mm 365 365 365 365 365 365 365 555 555 B mm 275 275 275 275 275 275 275 360 360 C mm 620 620 620 620 710 710 710 890 890 Weight 1 kg 19 19 19 19 27 27 27 60 60

1= filled with water in wor king conditions

○ The steam humidifier allows the handled air to be humidified. It consists in two sections: the MUV plenum with humidifier which contains the steam distributor and the PRV external steam producer featuring immersed electr odes.

○ ○ The humidifier is controlled by the KPAU humidistat panel accessory.

○ ○

BA SV MUV

A mm ≥ 300 B mm ≥ 200 C mm ≥ 200 D mm ≥ 400 E mm ≥ 700

1. Steam distribution pipe 2. Steam feed pipe connecti on

Page 42: K11142 ed.5 UTNA GB

42

UTNA electrical connection

UTNA 015÷038

B

OT

O

K

YN

R

N Brown O-T Orange - White O Orange Common K Black Maximum speed B Blue Medium speed R Red Minimum speed Y Yellow/Green

UTNA 015÷038 (Accessory KQE)

3 1 19 AB

2 7 AB

1 Maximum speed 2 Medium speed 3 Minimum speed 7 Common 19 Humidistat relay

AB-AB Humidistat consensus

UTNA 051 UTNA 078÷150 4P

UTNA 078÷150 4/6P – 4/8P

L1 L3 7

ABL2 1

AB

2

L1 Line 1 L2 Line 2 L3 Line 3 1 Maximum speed 7 Common 2 Minimum speed

AB-AB Humidistat consensus

Note: For further information on commands and controls and for the electrical connection diagrams, refer to the Technical Note code K20002.

Page 43: K11142 ed.5 UTNA GB
Page 44: K11142 ed.5 UTNA GB

RHOSS S.P.A. declines all responsabilities forpossible mistakes in the catalogue and reserves theright to alter the features of their products withoutnotice in the interests of continuous improvement.

K11142EN ed. 510.07 - 0.000 - Stampa:

UTNA 015÷150

RHOSS S.P.A. Via Oltre Ferrovia, 32 - 33033 Codroipo (UD) - Italytel. +39 0432 911611 - fax +39 0432 [email protected] - www.rhoss.it - www.rhoss.com

IR GROUP S.A.S.7 rue du Pont à Lunettes - 69390 Vourles - Francetél. +33 (0)4 72318631 - fax +33 (0)4 [email protected]

RHOSS Deutschland GmbHHölzlestraße 23, D-72336 Balingen, OT Engstlatt - Germanytel. +49 (0)7433 260270 - fax +49 (0)7433 [email protected] - www.rhoss.de

RHOSS MERCOSURBenjamin Constant 576 - 1er Piso C.P. 1214 - Asuncion Paraguaytel/fax +595 21 493 897 - www.rhossmercosur.com

Sedi commerciali Italia: / Italy branch offices:

Area Nord-Est: 33033 Codroipo (UD) - Via Oltre Ferrovia, 32tel. +39 0432 911611 - fax +39 0432 911600

Area Nord-Ovest: 20041 Agrate Brianza (MI)Centro Colleoni - Palazzo Taurus, 1tel. +39 039 6898394 - fax +39 039 6898395

Area Centro-Sud: 00199 Roma - Viale Somalia, 148tel. +39 06 8600699-707 - fax +39 06 8600747

Area Sud: 80143 Napoli - Via G. Porzio - Centro Direzionale - Isola G8tel. +39 081 7879121 - fax +39 081 7879135