Kapitel 06 G Online

Embed Size (px)

Citation preview

  • 8/9/2019 Kapitel 06 G Online

    1/24

    http://catalog.moeller.net

    Overload relay

    Motor protection is one of the most importanttasks when machines are to equiped electrically.You will find the correct solution for everyapplication, from the price efficient bimetalsolution up to the more demanding networked,full motor protection.

    Bimetal overload relays

    Overload relays up to 630 A- Saves mounting time due to direct mounting onto contactor- ATEX approval for the protection of EEx e motors up to 250 A- Single-phasing sensitivity offers wide-ranging motor protection- Integrated Test button gives higher safety

    Page 6/6

    ZEV electronic motor-protective relayOverload relays up to 820 A

    - Flexible mounting using Rogowski current transformers- Simple parameterisation reduced commissioning time- ATEX approval for the protection of EEx e motors- Short downtime due to error messages in display- Additional thermistor evaluation offers full motor protection

    Page 6/12

    EMT6 thermistor machine protection relays

    - Overload protection by direct evaluation of the windingtemperature

    - Fast recogniction of operating state by LED display- Suitable for overload monitoring of EEx e motors- Reduced variants due to wide-range power supply

    Page 6/16

  • 8/9/2019 Kapitel 06 G Online

    2/24

    Moeller HPL0211-2007/2008

    6/2

    Moeller HPL0211-2007/2008http://catalog.moeller. net http://catalog. moeller. net

    Overloadrelays

    Technical overviewOverload relays

    Setting ranges (A)(Note max. current ofthe contactor)

    DILEM DILM7DILM9

    DILM12

    DILM15 DILM17DILM25

    DILM32

    DILM40DILM50

    DILM65

    DILM80DILM95

    DILM115

    DILM150DILM170

    M185M225

    M250

    M300M400

    M500

    M580M650

    M750M820

    M1000Overload relays

    ZE

    ZB120.1 16

    ZB320.1 32

    ZB656 65

    ZB15025-150

    Z5-.../FF25050-250

    CT-operated overload relay

    ZW7-...1)

    42 630

    Electronic motor-protective relay

    ZEV2)

    1 820

    Thermistor machine protection overload relays

    EMT6((DB)K)

    Notes 1) Can only be used up to DILM5802) Can only be used up to DILM820

  • 8/9/2019 Kapitel 06 G Online

    3/24

    Moeller HPL0211-2007/2008

    6/4

    Moeller HPL0211-2007/2008http://catalog.moeller. net http://catalog. moeller. net

    BimetalRelay

    OrderingOverload relay for mini contactors

    Overloadreleases

    Contactsequence

    A ux il ia ry con ta ct s F or us e w it h S ho rt -c ir cu it pr ot ec ti on Part no.Article no.

    Pricesee price list

    Std. pack

    N/O =Normally

    N/C =Normally

    Type 1 coordination Type 2 coordination

    Ir gG/gL gG/gL

    A A A

    ZE overload relay for mini contactor

    Phase failure sensitivity to IEC/EN60947For direct mounting

    PTB 01 ATEX 3331

    0.10.16 1 N/O 1 N/C DILEMDIULEM/21/MVSDAINLEM

    20 0.5 ZE-0,16014263

    1 o ff Ove rload re leasShort-circuit promaximum permwith direct devic

    Observe manuaor English.

    0.160.24 1 ZE-0,24014285

    0.240.4 2 ZE-0,4014300

    0.40.6 2 ZE-0,6014333

    0.61 4 ZE-1,0014376

    11.6 6 ZE-1,6014432

    1.62.4 6 ZE-2,4014479

    2.44 10 ZE-4014518

    46 ZE-6014565

    69 ZE-9014708

    2 4 6 98 96

    9 7 9 5

    ZE

  • 8/9/2019 Kapitel 06 G Online

    4/24

    Moeller HPL0211-2007/2008

    6/6

    Moeller HPL0211-2007/2008http://catalog.moeller. net http://catalog. moeller. net

    BimetalRelay

    OrderingBimetal Relay up to 150 A

    Setting rangeOverload releases

    Contact sequence Auxiliarycontacts

    For use with Short-circuit protection Part no.Article no.

    Pricesee price list

    Std. pack

    N/O =Normally

    N/C =Normally

    Type 1coordination

    Type 2coordination

    Ir gG/gL gG/gL

    A A A

    ZB12 overload relays

    Phase failure sensitivity to IEC/EN60947, VDE 0660 Part 102For direct mounting

    0.10.16 1 N/O 1 N/C DILM7, DILM9,

    DILM12,DILM15,DIULM7,DIULM9,DIULM12,SDAINLM12,SDAINLM16,SDAINLM22

    25 0.5 ZB12-0,16

    278431

    1 o ff Ove rload re

    Short-circuitmaximum pewith direct d

    Suitable for

    PTB 04 ATEX

    Observe man

    0.160.24 1 ZB12-0,24278432

    0.240.4 2 ZB12-0,4278433

    0.40.6 4 ZB12-0,6278434

    0.61 4 ZB12-1278435

    11.6 6 ZB12-1,6278436

    1.62.4 10 ZB12-2,4278437

    2.44 16 ZB12-4278438

    46 20 ZB12-6278439

    610 50 25 ZB12-10278440

    912 ZB12-12278441

    1216 ZB12-16290168

    ZB32 overload relays

    Phase failure sensitivity to IEC/EN60947, VDE 0660 Part 102For direct mounting

    0.10.16 1 N/O 1 N/C DILM17,DILM25,DILM32,DIULM17,DIULM25,DIULM32,SDAINLM30,SDAINLM45,SDAINLM55

    25 0.5 ZB32-0,16278442

    1 o ff Ove rload reShort-circuitmaximum pewith direct d

    Suitable for

    PTB 04 ATEX

    Observe man

    0.160.24 1 ZB32-0,24278443

    0.240.4 2 ZB32-0,4278444

    0.40.6 4 ZB32-0,6278445

    0.61 4 ZB32-1278446

    11.6 6 ZB32-1,6278447

    1.62.4 10 ZB32-2,4278448

    2.44 16 ZB32-4278449

    46 20 ZB32-6278450

    610 50 25 ZB32-10278451

    1016 63 35 ZB32-16278452

    1624 100 35 ZB32-24278453

    2432 125 63 ZB32-32278454

    2 4 6 98 9 6 A2 14/

    22

    9 7 9 5

    2 4 6 98 96 14/

    22

    9 7 9 5

    ZB

  • 8/9/2019 Kapitel 06 G Online

    5/24

    Moeller HPL0211-2007/2008

    6/8

    Moeller HPL0211-2007/2008http://catalog.moeller. net http://catalog. moeller. net

    BimetalRelay

    OrderingBimetal Relay up to 150 A

    O ve rl oa d r el ea se s Con ta ct s eq ue nc e Aux il ia ry co nt ac ts F or u se w it h S ho rt -c ir cu it p ro te ct io n Part no.Article no.

    Pricesee price list

    Std. pack

    N/O =Normally

    N/C =Normally

    Type 1coordination

    Type 2coordination

    Ir gG/gL gG/gL

    A A A

    Overload relays ZB65

    Phase failure sensitivity to IEC/EN60947, VDE 0660 Part 102For direct mounting

    610 1 N/O 1 N/C DILM40,DILM50,DILM65,DIULM40,DIULM50,DIULM65,SDAINLM70,SDAINLM90,SDAINLM115

    50 25 ZB65-10278455

    1 o ff Ove rload re leasShort-circuit promaximum permwith direct devi

    Suitable for pro

    PTB 04 ATEX 30

    Observe manua

    1016 63 35 ZB65-16278456

    1624 63 50 ZB65-24278457

    2440 125 63 ZB65-40278458

    4057 160 80 ZB65-57278459

    5065 160 100 ZB65-65278460

    3550 DILM80,DILM95,DILM115,DILM150,DILM170DIULM80,DIULM95,DIULM115,DIULM150,SDAINLM140,SDAINLM165,SDAINLM200,SDAINLM260

    160 125 ZB150-50278462

    5070 250 160 ZB150-70278463

    70100 315 200 ZB150-100278464

    95125 315 250 ZB150-125278465

    120150 315 250 ZB150-150278466

    145175 315 250 ZB150-175107316

    Separate mounting

    3550 1 N/O 1 N/C 160 125 ZB150-50/KK278468

    1 o ff Ove rload re leasShort-circuit promaximum permwith direct devi

    Suitable for pro

    PTB 04 ATEX 30

    Observe manua

    5070 250 160 ZB150-70/KK278469

    70100 315 200 ZB150-100/KK278470

    95125 315 250 ZB150-125/KK278471

    120150 315 250 ZB150-150/KK278472

    145175 400 315 ZB150-175KK107317

    2 4 6 98 96

    9 7 9 5

    2 4 6 98 96

    9 7 9 5

    ZB

  • 8/9/2019 Kapitel 06 G Online

    6/24

    Moeller HPL0211-2007/2008

    6/10

    Moeller HPL0211-2007/2008http://catalog.moeller. net http://catalog. moeller. net

    BimetalRelay

    OrderingOverload relay, CT-operated overload relay

    Overloadreleases

    Contact sequence Auxiliary contacts For use with Short-circuit protection Part no.Article no.

    Pricesee price list

    Std. pack Notes

    N/O =Normally

    N/C =Normally

    Type 1coordination

    Type 2coordination

    Ir gG/gL gG/gL

    A A A

    Overload relay Z5 greater than 150A

    Phase failure sensitivity to IEC/EN60947

    5070 1 N/O 1 N/C DILM185DILM225DILM250

    250 160 Z5-70/FF250210070

    1 of f O ver loa d r ele atripping class 1Short-circuitprotection: Obthe maximumpermissible fusthe contactor.

    70100 315 200 Z5-100/FF250210071

    95125 315 250 Z5-125/FF250210072

    120160 400 250 Z5-160/FF250210073

    160220 Direct mountingSeparate mounting

    400500

    315400

    Z5-220/FF250210074

    200250 Direct mountingSeparate mounting

    400500

    315400

    Z5-250/FF250210075

    ZW7 current transformer-operated overload relays

    Separate mounting

    4263 1 N/O 1 N/C ZW7-63000245

    1 of f

    6090 ZW7-90002618

    85125 ZW7-125004991

    110160 ZW7-160007364

    160240 ZW7-240009737

    190290 ZW7-290052448

    270400 ZW7-400045329

    360540 ZW7-540047702

    420630 ZW7-630050075

    1 3 5 97 95

    2 4 6 98 96

    9698

    9597

    Z5, ZW7

  • 8/9/2019 Kapitel 06 G Online

    7/24

    Moeller HPL0211-2007/2008

    6/12

    http://catalog.moeller.net

    Overloadrelay

    s

    DescriptionOverload relays

    ZEV electronic overload relay for motor currents from 1 820 A

    Technological advances require completely new approaches: the application ofnewly developed sensor systems and tripping units has made motor protectionconsiderably simpler and more economical. All Z overload relays provide thestandard functions: protection in the event of phase failure, overload, or currentimbalance. The innovative ZEV motor-protective system from Moeller can now doall these things and much more:

    Even the most severe starting situations can be dealt with by the ZEV motor-protective system. The enhanced tripping classes (up to CLASS40) provide reliableprotection for motors with starting times of up to 40 seconds. Protection for anymotor starting situation can be optimally set by preselecting one of the eighttripping classes between 5 and 40 seconds. An earth fault is quickly detected by theexternal core-balance transformers. The integrated thermistor connection allowsthe relay to be upgraded to provide a full motor-protective system.

    The LCD display guides the user through the setting menus and ensures straight-forward operation. In the event of a fault, the display shows the cause of the faultand enables rapid fault identification.Additional signal cables can be implemented via the freely configurable auxiliarycontacts 05-06 and 07-08.

    They can each be assigned one of the following functions: Early warning of overload Earth fault Thermistor tripping Internal fault

    The multi-voltage module automatically adapts to different voltagesfrom 24 240 V, 50/60 Hz,and 24 240 V DC, thus enabling flexible application with all conventional controlvoltages.

    Ring-type sensors enable the innovative ZEV motor protection system to be usedalso for small motors. With large motor currents and cable cross-sections, the sensorcables are simply wound round the incoming cable.A main current wiring system and complex cable matching for an additional deviceare no longer necessary, neither is the drilling of the mounting plate. Instead, thesensors are simply fastened with a Velcro fastener.This saves mounting time and expense. The volume of 58 times less thanconventional transformers enables the saving of valuable mounting space in thecontrol panel.

    General

    Application

    Handling

    Engineering

    Mounting

    ZEV

  • 8/9/2019 Kapitel 06 G Online

    8/24

    6/13

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    Electronicmot

    or-protectiverelay

    ZEV Electronic Motor-Protective RelayBasic units, accessories

    Length Diameter Overload releases For use with Faultcurrents

    Part no.Article no.

    Pricesee price list

    Std. pack

    Ir

    mm mm A A

    ZEV

    PTB 01 ATEX 3233

    1820 DILEMDILM820 ZEV209634

    1 off

    Current sensors

    6 125 DILEMDILM7DILM25 ZEV-XSW-25209635 1 off

    13 365 DILM7DILM65 ZEV-XSW-65209636

    21 10145 DILM12DILM150 ZEV-XSW-145209637

    110 40820 DILM40DILM820 ZEV-XSW-820209641

    Connecting cables

    200 ZEV-XSW-25ZEV-XSW-65ZEV-XSW-145ZEV-XSW-820

    ZEV-XVK-20209643 1 off

    400 ZEV-XVK-40209644

    800 ZEV-XVK-80209645

    SSW core-balance transformers

    For earth-leakage monitoring 40 0.3 SSW40-0,3028286

    1 off

    0.5 SSW40-0,5028305

    1 SSW40-1028306

    65 0.5 SSW65-0,5028307

    65 1 SSW65-1028316

    120 0.5 SSW120-0,5028319

    120 1 SSW120-1028321

    Fixing bracket

    ZEVZEV-XSW-25ZEV-XSW-65ZEV-XSW-145easy..., MFD...PS4..., EM4...LE4...

    ZB4-101-GF1061360

    9 off

    Documentation

    ZEV motor protective relayOverload monitoring of EEx e motors

    German AWB2300-1433D259711

    1 off

    English AWB2300-1433GB267430

    1 off

    ZEV, SSW

    6/14 E i i

  • 8/9/2019 Kapitel 06 G Online

    9/24

    Moeller HPL0211-2007/2008

    6/14

    http://catalog.moeller.net

    Electronicmot

    or-protectiverelay

    EngineeringSelection aid

    1) IF: Internal fault

    5 1 0 15 2025 30 35 40

    IF1)

    IF1)

    Class

    Y1

    T1

    T2

    Y2C2C1 A1 A2 9 5 9 7 0 5 0 7

    9 6 9 8 0 6 0 8

    ~ =

    NL3L2L1

    M3~

    Z2

    Z1

    l%

    L1 L2 L3

    PE

    PE

    Ie

    Ie

    > 105 %

    Ie

    > 105 %

    !

    P

    !

    1 820 A

    Mode

    TestReset

    Up

    Down

    Reset

    Menu

    ON OFF

    Reset

    Hand Auto

    Class

    Fault

    Freeparameter 1

    Freeparameter 2

    Freeparameter

    1

    Freeparameter

    2

    Inputs Outputs

    A 1/A 2 Rated control voltage 95/96 N/C contact overload/thermistor

    T 1/T 2 Thermistor sensor 97/98 Make contact overload/thermistor

    C 1/C 2 SSW core-balance transformer 05/06 N/C contact freely assignable

    Y 1 /Y 2 Remote r eset 07/08 Make con tac t f reely ass ignab le

    Switchgear and cable sizing correspond to the respective starting inertia (CLASS)

    The switchgear is designed for CLASS 10 in normal and overload operation. To ensure that the switchgear (circuit-breaker and contactor) as well as the cables are notoverloaded with extended tripping times, they must be over-dimensioned accordingly. The rated operational current Ie for switchgear and cables can be calculated withthe following current factor while taking the tripping class into account:

    Tripping class Class 5 Class 10 Class 15 Class 20 Class 25 Class 30 Class 35 Class 40

    Current factor forrated operationalcurrent Ie

    1.00 1.00 1.22 1.41 1.58 1.73 1.89 2.00

    Rated motor currents < 1 AWith the ZEV-XSW-25 to ZEV-XSW-145 push-through sensors, the motor incomer cables for each phase are pushed through the push-through openings. With motor cur-rents of less than 1 A, the motor incomer cables are looped into the ZEV-XSW25.

    Number of loops n 4 3 2

    Rated motor current IN A 0.250.32 0.330.49 0.50.99

    Set current on the relayIE between the

    lowest and highest values

    A 1.001.28 1.001.47 1.001.98

    The set current IE of the device is calculated by: IE = nxIN

    ZEV

    6/15Engineering

  • 8/9/2019 Kapitel 06 G Online

    10/24

    6/15

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    Electronicmotor-protectiverelay

    EngineeringCharacteristics curves

    Tripping characteristics

    With a phase failure or unbalance> 50 %, the ZEV will trip within 2.5 seconds.

    Tripping times for ZEV electronic motor-protective relay

    Tripping class, adjustable CLASS 5 10 15 20 25 30 35 40

    Tripping times in s (g20 %) at 3-pole symmetric loading from cold state

    Current setting IEx 3 11.3 22.6 34 45.3 56.6 67.9 79.2 90.5

    x 4 8 15.9 23.9 31.8 39.8 47.7 55.7 63.6

    x 5 6.1 12.3 18.4 24.6 30.7 36.8 43 49.1

    x 6 5 10 15 20 25 30 35 40

    x 7.2 4.1 8.2 12.3 16.4 20.5 24.5 28.6 32.7

    x 8 3.6 7.3 10.9 14.6 18.2 21.9 25.5 29.2

    x 10 2.9 5.7 8.6 11.5 14.4 17.2 20.1 23

    Recovery time after overload trip(Overview of the recovery time in min)

    CLASS 5 10 15 20 25 30 35 40

    trecovery[min]

    5 6 7 8 9 10 11 12

    Thermistor trippingRated trip resistance R = 3200Og15 %

    Recovery resistance R = 1500O +10 %

    Total cold resistanceS RK F 1500Oat RK F 250O per sensor: 6 sensorsat RK F 100O per sensor: 9 sensors

    Ready to respond after trip at 5 K under response temperature

    Test button tripping time: 5 s

    EC prototype test certification number: PTB 01 ATEX 3233

    For protection of motors in EEx e area, also order AWB2300-1433G ZEV motor-protective system, Overload monitoring of motors in EEX e areas.

    20

    CLASS 40

    25

    15

    CLASS 5

    10

    tA

    100

    50

    20

    10

    5

    2

    1

    20

    10

    5

    2

    10.7 1 2 5 8

    3035

    xIe

    min

    s

    ZEV

    ZEV

    6/16 Ordering

  • 8/9/2019 Kapitel 06 G Online

    11/24

    Moeller HPL0211-2007/2008

    6/16

    http://catalog.moeller.net

    Thermistoroverloadrelaysformachine

    protection

    OrderingBasic units, accessories

    Description Rated operationalcurrent

    Conventionalthermal current

    Rated controlvoltage

    Part no.Article no.

    Pricesee pricelist

    Std.pack

    AC-15 AC14

    240 V 400 V

    Ie Ie Ith Us

    A A A V

    EMT6 thermistor machine protection relays

    Without automatic resetMains and fault LED display

    3 3 6 24 240 V 50/60 Hz,24 240 V DC

    EMT6066166

    1 off

    Without automatic resetMains and fault LED displayTrip with short-circuit in the sensor cable

    24 240 V 50/60 Hz,24 240 V DC

    EMT6-K269470

    Without automatic resetMains and fault LED display

    230 V 50/60 Hz EMT6(230V)066400

    Selector switch with/without automaticresetFor manual or remote resettingTest buttonMains and fault LED display

    24 240 V 50/60 Hz,24 240 V DC EMT6-DB066167

    Selector switch with/without automaticresetFor manual or remote resettingTest buttonMains and fault LED displayTrip with short-circuit in the sensor cable

    24 240 V 50/60 Hz,24 240 V DC

    EMT6-KDB269471

    Selector switch with/without automaticresetFor manual or remote resettingTest buttonMains and fault LED display

    230 V 50/60 Hz EMT6-DB(230V)066401

    Multifunction deviceSelector switch with/without automaticresetTrip with short-circuit in the sensor cableZero-voltage safeFor manual or remote resettingTest buttonShort-circuit recognition and zero-voltagesafety can be deactivatedMains and fault LED display

    24 240 V 50/60 Hz,24 240 V DC

    EMT6-DBK066168

    AccessoriesScrew adapterFor screw fixing

    CS-TE095853

    10 off

    DocumentationEMT6 thermistor overload relayOverload monitoring of machines in the EEx e area

    German AWB2327-1446D264853

    1 off

    English AWB2327-1446GB267010

    1 off

    EMT6

    6/17Ordering

  • 8/9/2019 Kapitel 06 G Online

    12/24

    6/17

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    Thermistorov

    erloadrelaysformachine

    protection

    OrderingBasic devices, accessories

    Terminal marking according to EN 50005 Notes

    Flow DiagramsLED display

    Supply voltage is available

    Device has tripped

    Device has tripped/short-circuit inthe sensor circuit

    EMT6-K, EMT6-(K)DB, EMT6-DBKAuto PTB 02 ATEX 3162

    With the EMT6, EMT6(230V), EMT6-DB and EMT6-DB(230V) an additional short-circuit protection in thesensor circuit with current monitor is to be provided.Observe the AWB2327-1446 manual (a6/16).

    Can be snap fitted on a top-hat rail to IEC/EN 60715.

    At RKF 250 per sensor: 6 sensors, at RKF 100 persensor: 9 sensors in the winding (fitted by customer),max. cable length to sensor 250 m (non-screened);Total thermistor resistance (cold) S RKF 1500

    Sensor circuit characteristic values at Us and +20 C

    EMT6...UT1-T2 IT1-T2

    RT1-T2 V DC max. mA max.

    T1, T2 short-circuited 1,9

    4 k 3 0,8

    T1-T2 open 5,1

    Functions that can be disconnected on the EMT6-DBK:

    Function disconnection via link

    Short-circuit detection Y1 Y3Zero voltage safety Y1 Y4

    EMT6-(K)DB, EMT6-DBKHand

    EMT6-DBKZero-voltage safe operation

    L +h

    h

    N

    US

    A1 2 1 1 3

    A2 T1 T2 2 2 1 4

    PTC

    Power Tr ipped

    Tripped LED

    A1/A2

    T1/T2 3.6 K1.6 K

    0

    1314, 2122

    +Lh

    hN

    US

    A1 21

    A2 T1 T2 22 14

    PTC

    13Y2Y1

    Power Tr ipped

    Tripped LED

    A1/A2

    T1/T2 3.6 K1.6 k

    0

    1314, 2122

    Y1/Y2, RESET

    L +h

    hN

    US

    A1 21

    A2 T1 T2 22 14

    PTC

    13Y2Y1 Y4Y3

    Power Tr ipped

    A1/A2

    T1/T2 3.6 K1.6 K

    0

    1314, 2122

    Y1/Y2, RESET

    Short-circuit

    Tripped LED

    60

    750

    1650

    4000

    12000

    20 5 +5 +15

    3600 Tripping

    1600 Reset

    Tolerance limitsTemperature

    NAT NATNAT NAT NAT

    Resistance

    [

    ]

    Resettingrange

    IEC-Tripping range

    [C]

    EMT6

    6/18 Ordering

  • 8/9/2019 Kapitel 06 G Online

    13/24

    Moeller HPL0211-2007/2008

    6/18

    http://catalog.moeller.net

    BimetalRelay

    OrderingAccessories

    For use with Part no.Article no.

    Pricesee pricelist

    Std. pack Notes

    Documentation

    Overload relaysOverload monitoring of EEx e motors

    ZB12...ZB32...

    AWB2300-1527D/GB284910

    1 off German/English

    ZB65...ZB150...

    AWB2300-1545D/GB102065

    Bases

    For separate mounting ZB32 ZB32-XEZ278473

    5 o ff Can be snap fitted on atop-hat rail to IEC/EN 60715 or can bescrew fitted.

    ZB65 ZB65-XEZ278474

    1 off

    Push-buttons

    For enclosed overload relaysMounting diameter: 22.3 mm

    External reset button IP65

    ZW7...ZB12ZB32ZB65ZB150

    M22-DZ-B254833

    10 o ff Blue button plate

    ZW7...ZB12ZB32ZB65ZB150

    M22-DZ-B-GB14254834

    Blue button plate:RESET

    Off button, IP65

    ZW7...ZB12ZB32ZB65ZB150

    M22-DZ-X254835

    10 o ff Wi thout but ton pl ate ,button plate must beadded

    Button plates

    M22-DZ-X M22-XD-R216423

    10 off Red legend plate

    M22-XD-R-X0218153

    Button plate, red withwhite circle

    M22-XD-R-GB0218194

    Red legend plate STOP

    Covers

    Z5-.../FF250 Z5/FF250-XHB215217

    1 o ff Separate mounting Fitted directly to thecontactor

    Direct fittingZ5-.../FF250 toDILM185,DILM225,DILM250

    Z5/FF250-XHB-Z215218

    Z5/FF250

    -XHB

    Z5/FF250

    -XHB

    Z5-.../FF250

    Z5-.../FF250

    DIL M400

    -XHB

    Z5/FF250

    -XHB-Z

    Z5/FF250

    -XHB

    DIL M185/

    225/250

    ZB, Z5, ZW7

    6/19Engineering

  • 8/9/2019 Kapitel 06 G Online

    14/24

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    BimetalRelay

    g gSelection data

    Selection data ZEZB12

    ZB32, ZB65, ZB150 Z5 ZW7 ZEV

    Phase-failure sensitivity b b b b

    Temperature compensation b b b b b

    Auxiliary switch 1 M + 1 B b b b b b

    Test/off button b b b b b

    Reset button manual/auto b b b b b

    Separate mounting b b b b

    Protection of EEx e-motors (PTB) b b b b

    Protection with heavy starting duty b b

    Trip-free release b b b b b

    P standard features

    EU prototype test certificate number

    ZEVZEZB12ZB32ZB65ZB150EMT6

    PTB 01 ATEX 3233PTB 01 ATEX 3331PTB 04 ATEX 3022PTB 04 ATEX 3022PTB 04 ATEX 3022PTB 04 ATEX 3022PTB 02 ATEX 3162

    Protec tion of single -phase and DC current motors : Mounting posi tion :

    1 pole 2 pole ZE ZB12, ZB32, ZB65, ZB150, Z5

    These tripping characteristics are mean values of the spread at 20 C ambient temperature in a cold state. Tripping time depends on response current. When the devicesare at operational temperature the tripping time of the overload relay reduces to approx. 25 % of the read off value. Specific characteristics for each individual settingrange can be found in the manual onaPage 6/18

    2h1006040

    20

    10

    6421

    402010642

    10.6

    ZB12, ZB32,ZB65, ZE

    1 1. 5 2 3 4 6 8 1 015 2 0x Setting current

    2-phaseSeconds

    M

    inutes

    3-phase

    2h10060402010

    6421

    402010

    642

    10.6

    ZB150

    6 8 10 15203 41 1.5 2x Setting current

    2-phaseSeconds

    M

    inutes

    3-phase

    2 h1006040

    20

    10

    642

    140

    201064

    2

    1

    1 1.5 2 3 4 6 8 1015 200.6

    ZW7

    M

    inutes

    Seconds

    Rated current

    Lowest level

    Highest level

    2h1006040

    20

    10

    6421

    402010642

    10.6

    Z5

    6 8 1015 203 41 1.5 2x Setting current

    2 phaseSeconds

    M

    inutes

    3 phase

    ZE, ZB, Z5, ZW7, ZEV

    6/20 Technical Data

  • 8/9/2019 Kapitel 06 G Online

    15/24

    Moeller HPL0211-2007/2008 http://catalog.moeller.net

    BimetalRelay

    Bimetal Relay

    ZE ZB12, ZB32 ZB65 ZB150(KK)

    General

    Standards IEC/EN 60947, VDE 0660, UL, CSA

    Climatic proofing Damp heat, constant, to IEC 60068-2-78;Damp heat, cyclic, to IEC 60068-2-30

    Ambient temperature

    Open1) C 2550 2555 2555 2555

    Enclosed1) C 2540 2540 2540 2540

    Temperature compensation Continuous

    Mounting position aEngineering selection data

    Weight 0.07 0.15 0.25 1.64

    Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27

    g 10 10 10 10

    Protection type IP20 IP 20 IP00 IP00

    Protect ion aga ins t d ir ec t contact when ac tuated f rom f ron t ( IEC 536 ) Finger- and back-o f-hand proof

    Main conducting paths

    Rated impulse withstand voltage Uimp V AC 6000 6000 6000 8000

    Overvoltage category/pollution degree III/3 III/3 III/3 III/3

    Rated insulation voltage

    AC Ui V AC 690 690 690 1000

    Rated operational voltage Ue V AC 690 690 690 1000

    Safe isolation to VDE 0106 Part 101 and Part 101/A1

    Between auxiliary contacts and main contacts V AC 300 440 440 440

    Between main circuits V AC 300 440 440 440

    Overload release setting range A 0.19 0.132 675 25150

    Temperature compensation residual error > 40C %/K F 0.25 F 0.25 F 0.25 F 0.25

    Short-circuit protection Maximum fuse apage 6/5 apage 6/7 apage 6/9 apage 6/9

    Current heat loss (3 conductors)

    Lower value of the setting range W 2.5 2.5 3 16

    Maximum setting W 6 6 7.5 18

    Terminal capacities

    Solid mm2 2x (0.75 2.5) 2x (1 6) 2x (1 16)4) 2x (4 16)

    Flexible with ferrule mm2 2x (0.5 1.5) 2x (1 4)2x (1 6)3)

    1x (125)2x (110)2)

    1x (4 70)2x (4 50)

    Stranded mm2 1x (1625) 1x (1650)2x (1650)

    Solid or stranded AWG 18 14 14 8 14 2 2/0

    Terminal screw M3.5 M4 M6 M10

    Tightening torque Nm 1.2 1.8 3.5 10

    Tools

    Pozidriv screwdriver Size 2 2 2

    Standard screwdriver mm 0.8x 5.5 1x 6 1x 6

    Hexagon socket-head spanner SW mm 5

    Notes 1) Ambient temperature: Operating range to IEC/EN 60947, PTB: -5C to +55C2) Main contacts terminal capacity solid and stranded conductors with ferrules: When using 2 conductors use identical cross-section3) 6 mm2 flexible with ferrules to DIN 462284) at ZB65-XEZ max 1x (116)

    ZE, ZB

    6/21Technical Data

  • 8/9/2019 Kapitel 06 G Online

    16/24

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    BimetalRelay

    Overload relay, CT-operated overload relay

    Z5-.../FF250 ZW7

    General

    Standards IEC/EN 60947, VDE 0660, UL, CSA

    Climatic proofing Damp heat, constant, to IEC 60068-2-78;Damp heat, cyclic, to IEC 60068-2-30

    Ambient temperature

    Open1) C 2550 2550

    Enclosed1) C 2540 2540

    Temperature compensation Continuous Continuous

    Mounting position aEngineering selection data As required

    Weight 1.55 0.8

    Mechanical shock resistance half-sinusoidal shock 10ms to IEC 60068-2-27

    g 10 10

    Protection type IP00 IP00

    Protection against direct contact when actuated fromfront (IEC 536)

    With terminal cover Finger- and back-of-hand proof

    Main conducting paths

    Rated impulse withstand voltage Uimp V AC 8000 6000

    Overvoltage category/pollution degree III/3 III/3

    Rated insulation voltage

    AC Ui V AC 1000 690

    Rated operational voltage Ue V AC 1000 690

    Safe isolation to VDE 0106 Part 101 and Part 101/A1

    Between auxiliary contacts and main contacts V AC 440 440

    Between main circuits V AC 440 440

    Overload release setting range A 50250 40630

    Temperature compensation residual error > 40C %/K F 0.25

    Short-circuit protection Maximum fuse apage 6/11 With overload relay in conjunction witha transformer as required for thecontactor

    Current heat loss (3 conductors)

    Lower value of the setting range W 16 3

    Maximum setting W 28 10

    Terminal capacities

    Flexible with cable lug mm2 95

    Stranded with cable lug mm2 120

    Solid or stranded AWG 250 MCM

    Flat conductor Number of segmentsx widthxthickness

    mm 6x 16x 0.82)

    Busbar Width mm 20x 3

    Push-through opening mm 27

    Terminal screw M8x 25

    Tightening torque Nm 24

    Tools

    Hexagon head spanner SW mm 13

    Notes 1) Ambient temperature: operating range to IEC/EN 60947, PTB: -5C to +50C2) Flat conductor terminal capacity: fixing with box terminal

    Z5, ZW7

    6/22 Technical DataO l d l

  • 8/9/2019 Kapitel 06 G Online

    17/24

    Moeller HPL0211-2007/2008 http://catalog.moeller.net

    BimetalRelay

    Overload relays

    ZE ZB12, ZB32 Z5-.../FF250 ZW7

    Auxiliary and control circuits

    Rated impulse withstand voltage Uimp V 6000 6000 6000 6000

    Overvoltage category/pollution degree III/3 III/3 III/3 III/3

    Terminal capacities

    Solid mm2 2x (0.75 2.5) 2x (0.754) 2x (0,75 4) 2x (0.75 4)

    Flexible with ferrule mm2 2x (0.5 1.5) 2x (0.75 2.5) 2x (0,75 2,5) 2x (0.75 2.5)

    Solid or stranded AWG 2x (18 12) 2x (18 12) 2x (18 12) 2x (18 12)

    Terminal screw M3.5 M3.5 M3.5 M3.5

    Tightening torque Nm 0.8 1.2 0.8 1.2 0.8 1.2 0.8 1.2

    Tools

    Pozidriv screwdriver Size 2 2 2 2

    Standard screwdriver mm 0.8x 5.5 1x 6 1x 6 1x 6

    Rated insulation voltage Ui V AC 690 500 500 500

    Rated operational voltage Ue V AC 500 500 500 500

    Safe isolation to VDE 0106 Part 101 and Part 101/A1

    between the auxiliary contacts V AC 300 240 240 240

    Conventional thermal current Ith A 6 6 6 6

    Rated operational current

    AC15

    Make contact

    120 V Ie A 1.5 1.5 1.5 1.5

    240 V Ie A 1.5 1.5 1.5 1.5

    415 V Ie A 0.5 0.5 0.5 0.5

    500 V Ie A 0.3 0.5 0.5 0.5

    Break contact

    120 V Ie A 1.5 1.5 1.5 1.5

    240 V Ie A 1.5 1.5 1.5 1.5

    415 V Ie A 0.7 0.9 0.9 0.9

    500 V Ie A 0.5 0.8 0.8 0.8

    DC-13 L/R 15 ms1)

    24 V Ie

    A 0.9 0.9 0.9 0.9

    60 V Ie A 0.75 0.753) 0.753) 0.753)

    110 V Ie A 0.4 0.4 0.4 0.4

    220 V Ie A 0.2 0.2 0.2 0.2

    Short-circuit rating without welding

    max. fuse2) A gG/gLA gG/gL

    4 6 6 6

    Notes 1) Rated operational current: Making and breaking conditions to DC-13, L/R constant as s tated2) See overlay: Fuses for short-circuit rating time/current characteristic (please enquire)3) Rated operational current DC-13, 60 V: N/O auxiliary contact 0.6 A

    ZE, ZB, Z5, ZW7

  • 8/9/2019 Kapitel 06 G Online

    18/24

    6/24 Technical DataElectronic motor protective relay

  • 8/9/2019 Kapitel 06 G Online

    19/24

    Moeller HPL0211-2007/2008 http://catalog.moeller.net

    Electronicmo

    tor-protectiverelay

    Electronic motor-protective relay

    ZEV-XSW-25 ZEV-XSW-65 ZEV-XSW-145 ZEV-XSW-820

    General

    Standards IEC/EN 60947, VDE 0660, UL, CSA

    Climatic proofing Damp heat, constant, to IEC 60068-2-78;Damp heat, cyclic, to IEC 60068-2-30

    Ambient temperature1)

    Open C 2560 2560 2560 2560

    Enclosed C 2540 2540 2540 2540

    Storage C 4080 4080 4080 4080

    Temperature compensation Continuous

    Mounting position As required

    Weight kg 0.23 0.4 0.45 0.14

    Mechanical shock resistance half-sinusoidal shock10 ms to IEC 60068-2-27

    g 15 15 15 15

    Protection type IP20 IP20 IP20 IP20

    Protection against direct contact when actuated fromfront (IEC 536)

    Finger- and back-of-hand proof

    Main conducting paths

    Rated impulse withstand voltage Uimp V AC 2) 2) 2) 8000

    Overvoltage category/pollution degree 2) 2) 2) III/3

    Rated insulation voltageAC Ui V AC 2) 2) 2) 1000

    Rated operational voltage Ue V AC 2) 2) 2) 1000

    Safe isolation to VDE 0106 Part 101 and Part 101/A1

    Between busbar and sensor V AC 500

    Overload release setting range A 125 365 10145 40820

    Short-circuit protection Maximum fuse With overload relay in conjunction with a transformer as required for the contactor

    Push-through opening mm 6 13 21 110

    Notes 1) Operating range to IEC/EN 60947, PTB: -5C to +50C2) The main current parameters are defined by the main current wiring which is used.

    ZEV

    6/25Technical DataThermistor overload relays for machine protection

  • 8/9/2019 Kapitel 06 G Online

    20/24

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    Thermistoroverloadrelaysformachine

    protection

    Thermistor overload relays for machine protection

    EMT6

    General

    Standards IEC/EN 60947, VDE 0660, EN 55011

    Climatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC60068-2-30

    Ambient temperature

    Open C 2560

    Enclosed C 2545

    Storage C 4560

    Mounting position As required

    Weight kg 0.15

    Mechan ica l shock r es is tance half -s inuso idal shock 10 ms to IEC 60068-2-27 g 10

    Protection type IP20

    Protect ion aga ins t d ir ec t contact when ac tuated f rom f ron t ( IEC 536 ) F inger- and back-o f-hand p roo f

    Safe isolation to VDE 0106 Part 101 and Part 101/A1

    between the contacts V AC 250

    between contacts and power supply V AC 250

    Auxiliary and control circuits

    Rated impulse withstand voltage Uimp V AC 6000

    Overvoltage category/pollution degree III/3

    Terminal capacities Auxiliary and control circuits

    Solid mm2 1x 2.52x (0.5 1.5)

    Flexible with ferrule mm2 1x 2.52x (0.5 1.5)

    Solid or stranded AWG 20 14

    Terminal screw M3.5

    Tightening torque Nm 1.2

    Tools

    Pozidriv screwdriver Size 2

    Standard screwdriver mm 1x 6

    Auxiliary power circuit

    Rated insulation voltage Ui V 400Rated operational current

    AC-14

    Make contact

    415 V Ie A 3

    Break contact

    415 V Ie A 3

    AC15

    Make contact

    240 V Ie A 3

    415 V Ie A 1

    Break contact

    240 V Ie A 3

    415 V Ie A 1

    Max. short-circuit protective device

    Fuse gG/gL A 6

    Control circuit

    Rated insulation voltage Ui V 240

    Rated operational voltage Ue V 2401)

    Pick-up and drop-out values xUe 0.85 1.1

    Power consumption

    AC VA 3.5

    DC W 2

    Trip at approx. O 3600

    Recovery at approx. O 1600

    Notes 1) EMT6(-DB)230V:Ue = 230 V

    EMT6

    6/26 DimensionsBimetal Relay

  • 8/9/2019 Kapitel 06 G Online

    21/24

    Moeller HPL0211-2007/2008 http://catalog.moeller.net

    Overloadrela

    ys

    Bimetal Relay

    Overload relay Base

    ZE ZB32-XEZ ZB65-XEZ

    ZB12 ZB32

    a OFFb Reset/ON

    ZB65

    a OFFb Reset/ON

    5.5

    58

    = 5

    45

    32

    49

    106

    >

    5

    b2

    16.5

    c2

    b

    a

    c

    b1

    a1

    2x d

    Part no. ZB32 ZB65

    a 45 60

    b 85 86

    c 90.5 112

    c2 3.8 4.7

    a1 35 50

    b1 75 75

    b2 40.5 47

    d M4 M5

    45

    27.5

    39 88

    84

    53

    34

    120

    a

    b

    45

    27.5

    39

    102

    62

    42

    136

    ab

    172

    40

    60

    46.5

    35 7.5

    132

    96.5

    a

    b

    ZE, ZB

    6/27DimensionsBimetal Relay

  • 8/9/2019 Kapitel 06 G Online

    22/24

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    Overloadrela

    ys

    y

    Overload relay

    ZB150

    a OFFb Reset/ON

    ZB150KK

    a OFFb Reset/ON

    a

    b

    100

    134

    44

    74

    118

    95

    516.5

    91

    90

    150

    170

    156

    160

    2

    77

    70

    o7

    1217

    4

    7

    5

    16.5

    63

    129

    134

    100

    118

    99

    95

    o 7

    a

    b

    ZB

    6/28 DimensionsBimetal Relay

  • 8/9/2019 Kapitel 06 G Online

    23/24

    Moeller HPL0211-2007/2008 http://catalog.moeller.net

    Overloadrelays

    Overload relay greater than 150 A

    Z5-.../FF250

    a OFFb Reset/ON

    Current transformer-operated overload relay

    ZW7

    a Reset/on

    Thermistor over load relays for machine protec tion External reset buttonOff button

    EMT6... M22-DZ-BM22-DZ-X

    110

    121

    96

    128

    74

    144

    169

    48

    25 5

    16.5

    144

    111

    94

    7

    7

    11

    a

    b

    a

    b

    200

    185

    6565

    71

    27

    7.5

    26

    55

    21

    857

    1 44

    33

    8

    4.3

    185

    M4

    44

    26

    55 a

    a

    1.5

    159

    172 250

    90 9090

    102

    78

    22.5

    100

    19

    2 5

    8

    2.5

    24.1

    22.3

    3.2

    o2

    9.5

    Z5, ZW7, EMT6

    6/29DimensionsElectronic motor-protective relay

  • 8/9/2019 Kapitel 06 G Online

    24/24

    http: //catalog.moel ler.net Moeller HPL0211-2007/2008

    Overloadrelays

    Electronic motor-protective relay Electronic motor-protective relay

    ZEV ZEV + ZEV-XSW-...

    Current sensors Current sensorsZEV-XSW-... ZEV-XSW-820

    Core-balance transformer

    SSW...

    29

    4.57.2

    45

    93

    37

    59.

    2

    78

    103

    75

    c1

    Part no. c1

    ZEV + ZEV -XSW-25 120

    ZEV + ZEV -XSW-65 128

    ZEV + ZEV-XSW-145 134

    93 3

    735

    78

    103

    c

    8

    a1

    4.5

    a

    d2

    d2

    3

    5

    d1

    Rfrence a a1 c d1 d2

    ZEV + ZEV-XSW-25 45 24 50 6 11.2

    ZEV + ZEV-XSW-65 70 49 58 13 19

    ZEV + ZEV-XSW-145 90 68 65 21 26

    3125

    ~150

    35

    26

    37

    Part no. a a1 a2 b b1 c d e

    SSW40-... 64 50 38 100 80 86 4.5 40

    SSW65-... 75 60 43 124 100 112 4.5 65

    SSW120-... 86.5 70 54.5 200 170 205 4.5 120

    a1

    a2

    b b1

    c

    e

    a

    d

    ZEV