1
F28-US06-00 PLC CONTROL PANEL 5563 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F407 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F302 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F303 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F402 VSD # VSD # VSD # VSD # VSD # US06-V602 VSD EF135-14-00 US06-V702 VSD PMP261-2-54 US06-V703 VSD PMP261-2-70 US06-V704 VSD PMP262-2-20 US06-V705 VSD PMP266-2-05 VSD # US06-V603 VSD EF135-16-00 VSD # VSD # VSD # US06-V605 VSD EF132-09-00 US06-V606 VSD EF134-02-11 US06-V604 VSD MAH103-6-00 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F408 MCC FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 2-F1-N-5NM255 F28-US06-M502 MCC FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 2-F1-Z-5EM261 F28-US06-M503 MCC FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 2-F1AA-5NM265 F28-US06-M504 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 EOL F28-US06-F403 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F404 FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F406 F28-US21-00 CPLX BREATHING AIR F28-US27-00 CPLX WET VACUUM FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 VFB-1519 LIQUID SEPARATOR WET VACUUM 84 M 84 M 112 M 68 M 61 M 106 M 26 M 204 M 106 M 112M 50 M 93 M 169 M 26 M 142M 124M 125M 123M 108M 145M 95M 108M EOL FLEX REMOTE I/O PANEL #1 #2 #3 #4 #5 #0 #6 #7 F28-US06-F304 EOL TP EOL TP EOL TP EOL TP EOL TP EOL TP F28-TMXW01-00 F28-BCS-NA01-00 1786 RPFM 1786 RPA VSD # US06-V706 F28B-PMP266-2-05 20M VSD # US06-V707 VSD PMP702-2-05 50 M VSD # US06-V607 VSD EF135-22-00 100 M EOL TP 74 M EOL TP VSD # US06-V505 F28-PMP113-2-00 180 m F28-U821D F28-U821E F28-U821F(Future) F28-U522C PURIFIER ROOM MODBUS TCP/IP - - 1 1 1=1 NONE SCHEMATIC NETWORK TOPOLOGY FMS CONTROLNET-US06 LC11 - I & C KBI-0219 KBI-0219 A0 DRAWING SCALE PLOT SCALE OLD DWG NO. SHEET OF DRAWING NO. FILE NAME FWR NO. DATE EQT CODE APPROVED ENGINEER PLANNING SAFETY CROSSCHECK DRAWN CHECKED REV. NO. REVISION DESCRIPTION APPROVED DATE Lachish Campus Qiryat Gat 82109, Israel R Intel Israel P.O. Box 82 IT IS UNDER THE VENDORS RESPONSIBILITY AND SCOPE OF WORK TO CHECK GIVEN MEASUREMENTS AND ELEVATIONS ON SITE BEFORE PREFABRICATION!! NOTE: F28/F28A PROJECT ENGINEERING INTEL CORPORATION. THIS DRAWING CONTAINS INFORMATION WHICH IS THE C HENSEL PHELPS KEYED NOTES GENERAL NOTES A REFER TO KCI-0201 FOR CONTROL NET INSTALLATION REQUIREMENTS. B QUANTITY AND TYPE OF I/O MODULES IN FLEX PANEL SHOWN FOR ILLUSTRATION ONLY. FOR ACTUAL TYPE AND QUANTITY REFER TO FLEX I/O MAP DRAWING ASSOCIATED WITH THIS PANEL. C COMMUNICATION CABLE LENGTHS ARE APPROXIMATE, CONTRACTOR TO FIELD VERIFY LENGTHS BEFORE COMMENCING INSTALL. 1 1 CONTRACTOR TO RELOCATE END OF LINE RESISTOR AND MAINTENANCE TAP. 2 PROVIDE AND INSTALL PROSOFT ILX56 FOR PURIFIERS COMMUNICATION. 3 TELECOMMS TO PROVIDE & INSTALL T.O. FOR EQUIPMENT. 4 CONTRACTOR TO INSTALL AI CARD TYPE 1794-IE8 IN SLOT #2. 5 CONTRACTOR TO PURCHASE AND INSTALL AO CARD TYPE 1794-OE4, CABLES AND MODULE IN SLOT#5. NAME: KBI-0219.DWG USER: Lipov,Maxim/PHX DATE: 9/3/2015 2:05 PM 0 ISSUED FOR MODELING DE 10/10/14 1 IFM 6P-DRB04 DE 03/06/15 2 IFM 6P-DRB08 DE 03/09/15 1 3 3 3 2 3 3 SOW F28 FAB 1 2 1 2 2 2 5 2 2 2

KBI-0219

Embed Size (px)

DESCRIPTION

LSS Drawing

Citation preview

Page 1: KBI-0219

F28-US06-00

PLC CONTROL PANEL

55

63

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F407

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F302

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F303

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F402

VSD #

VSD #

VSD #VSD #VSD #

US06-V602

VS

D E

F1

35

-1

4-0

0

US06-V702

VS

D P

MP

26

1-2

-5

4

US06-V703

VS

D P

MP

26

1-2

-7

0

US06-V704

VS

D P

MP

26

2-2

-2

0

US06-V705

VS

D P

MP

26

6-2

-0

5

VSD #

US06-V603

VS

D E

F1

35

-1

6-0

0

VSD #

VSD # VSD #

US06-V605

VS

D E

F1

32

-0

9-0

0

US06-V606

VS

D E

F1

34

-0

2-1

1

US06-V604

VS

D M

AH

10

3-6

-0

0

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F408

MCC FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

2-F1-N-5NM255

F28-US06-M502

MCC FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

2-F1-Z-5EM261

F28-US06-M503

MCC FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

2-F1AA-5NM265

F28-US06-M504

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

EOL

F28-US06-F403

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F404

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F406

F28-US21-00

CPLX

BREATHING AIR

F28-US27-00

CPLX

WET VACUUMFLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

VFB-1519

LIQUID SEPARATOR

WET VACUUM

84 M

84 M 112 M 68 M

61 M

106 M 26 M

204 M 106 M 112M

50 M 93 M

169 M 26 M

142M

124M

125M

123M

108M

145M

95M

108M

EOL

FLEX

REMOTE I/O PANEL

#1 #2 #3 #4 #5#0

#6 #7

F28-US06-F304

EOL

TP

EOL

TP

EOL

TP

EOL

TP

EOL

TP

EOL

TP

F2

8-T

MX

W0

1-0

0F

28

-B

CS

-N

A0

1-0

0

1786

RPFM

1786

RPA

VSD #

US06-V706

F2

8B

-P

MP

26

6-2

-0

5

20M

VSD #

US06-V707

VS

D P

MP

70

2-2

-0

5

50 M

VSD #

US06-V607V

SD

E

F1

35

-2

2-0

0

100 M

EOL

TP

74 M

EOL

TP

VSD #

US06-V505

F2

8-P

MP

11

3-2

-0

0

180 m

F28-U821D F28-U821E F28-U821F(Future) F28-U522C

PURIFIER ROOM

MODBUS TCP/IP

-

-

1 11=1 NONE

SCHEMATIC

NETWORK TOPOLOGY

FMS CONTROLNET-US06

LC11 - I & C

KBI-0219 KBI-0219

A0

DRAWING SCALEPLOT SCALEOLD DWG NO. SHEET OF

DRAWING NO.FILE NAMEFWR NO.

DATE

EQT CODE

APPROVED

ENGINEER

PLANNING

SAFETY

CROSSCHECK

DRAWN

CHECKED

REV. NO. REVISION DESCRIPTION APPROVED DATE

Lachish Campus

Qiryat Gat 82109, Israel

R

Intel Israel

P.O. Box 82

IT

IS

U

ND

ER

T

HE

V

EN

DO

RS

R

ES

PO

NS

IB

IL

IT

Y A

ND

S

CO

PE

O

F W

OR

K T

O C

HE

CK

G

IV

EN

M

EA

SU

RE

ME

NT

S A

ND

E

LE

VA

TIO

NS

O

N S

IT

E B

EF

OR

E P

RE

FA

BR

IC

AT

IO

N!!

NO

TE

:

F28/F28A PROJECT ENGINEERING

INTEL CORPORATION.

THIS DRAWING CONTAINS

INFORMATION WHICH IS THE

C

HENSEL PHELPS

KEYED NOTES

GENERAL NOTES

A REFER TO KCI-0201 FOR CONTROL NET INSTALLATION REQUIREMENTS.

B QUANTITY AND TYPE OF I/O MODULES IN FLEX PANEL SHOWN FOR

ILLUSTRATION ONLY. FOR ACTUAL TYPE AND QUANTITY REFER TO

FLEX I/O MAP DRAWING ASSOCIATED WITH THIS PANEL.

C COMMUNICATION CABLE LENGTHS ARE APPROXIMATE, CONTRACTOR

TO FIELD VERIFY LENGTHS BEFORE COMMENCING INSTALL.

1

1 CONTRACTOR TO RELOCATE END OF LINE RESISTOR AND

MAINTENANCE TAP.

2 PROVIDE AND INSTALL PROSOFT ILX56 FOR PURIFIERS

COMMUNICATION.

3 TELECOMMS TO PROVIDE & INSTALL T.O. FOR EQUIPMENT.

4 CONTRACTOR TO INSTALL AI CARD TYPE 1794-IE8 IN SLOT #2.

5 CONTRACTOR TO PURCHASE AND INSTALL AO CARD TYPE 1794-OE4,

CABLES AND MODULE IN SLOT#5.

NAME: KBI-0219.DWG USER: Lipov,Maxim/PHX DATE: 9/3/2015 2:05 PM

0 ISSUED FOR MODELING DE 10/10/14

1 IFM 6P-DRB04 DE 03/06/15

2 IFM 6P-DRB08 DE 03/09/15

1

3332 33

SOW F28 FAB

1

2

1

2

2

2

5

2 2

2