Type No.NR 60 level sensor (voltage rating DC9-36V)
MediaW for water and liquids of similar viscosities (εr = 35 to 85) F for oil and fuel (εr = 1.5 to 5.0)
Process Connection1 thread M 14 x 1.5 DIN 13, part 6 2 thread 1/4" NPTF ANSI B1.20.23 thread 3/8" NPTF4 thread M 18 x 1.5
FunctionA Minimum OC (open circuit principle) B Maximum OC (open circuit principle) -upon request-C Minimum RC (closed circuit principle)D Maximum RC (closed circuit principle) -upon request-
Output signalL LSS (minus switching)H HSS (plus switching) -upon request-
Self-test function0 0 sec. (standard for Function C)2 2 sec. (standard for Function A)
Response delay0 0 sec.1 7 sec. (standard)
Connection methodA bayonet B16S IP65B thread M27x1 IP67C bayonet DIN 72585-A1-3.1-Sn/kl IP69kD cable FLR 3x0.75 mm2/AWG 18 IP69k
Cable connection(only with connection method D)1 without plug
Cable length(only with connection method D)1 250 mm
NR60 - W 1 A L 2 1 A . . Ordering example
Level Sensor NR 60
04/05 159
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Level Sensor NR 60 is designed to monitor water, oils and fuels. It isthe ideal solution for a wide range of uses, especially in theautomotive and marine industry.
Features
Ordering information Technical data
Accessories
Options
EMC tested transistor output no moving parts maintenance free overload / short circuit protected environmental protection class up to IP69 customised signal delay and response time possible 1 A signal output up to +125 °C (+257 °F)
0Z031Z010001 Adapter M27 x 1 / 3/4" NPTF0Z051Z003011 Connector, M27 x 1, 90 °0Z051Z003012 Connector, M27 x 10Z051Z003010 Connector, bayonet 16S0Z051Z003009 Connector, bayonet 16S, 90°
AC voltage ratings and relay outputs:only with power supply NG 03 (see page 177)
Input voltage DC 9...36 V or with power supply NG 03
Closed-circuit currentconsumption: approx. 6 mA
Output signal LSS NPN transistor, low side switchingIMAX = 1 A short-circuit and overload protected
over the ambient temperature range
Voltage drop < 300 mV
Ambient temperature -30 °C...+125 °C / -22 °F...+257 °F
Medium temperature -30 °C...+125 °C / -22 °F...+257 °F
Response delay approx. 7 s (standard)
Switching point hysteresis horizontally mounted:
(depending on viscosity of NR 60-F = max. 10.5 mm (sensor dia.)medium) NR 60-W = max. 5 mm (sensor dia.)
Degree of protection IP65...IP69K (see ordering code)(IEC 529/DIN 40050)
Cable connection bayonet B16S, or DIN 72585-A1-3.1-Sn/kl or M27x1 thread or fixed cable FLR 3x0.75 mm2/AWG 18
Pressure resistance 25 bar/367.5 PSI
Reverse polarity protection in-built
Materialprobe coating ETFEfitting Ms sealing (0 ring) Viton®
housing Ms
Material specification ETFE = Tefzel® (Ethylene Tetrafluoromethylene)Ms = brass
Mounting thread M14x1.5, or 1/4" NPTF, or 3/8” NPTF, or M18x1.5
Mounting attitude optional
Cable length standard without cable (connection methods A, B, C) max. 300 m, LVCC 3x0.2 mm2/AWG 24Observe voltage drop! standard 250 mm (connection method D 1 1), other lengths upon request
Mass approx. 125 g
mark to demonstrate compliance with applicable directive.
NR 60-...
Level Sensor NR 60
04/05160
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Status indication factory preset
Dimensions
Function: Minimum OC Function: Minimum RC
Medium level Transistor output (LSS) Transistor output (LSS)Medium level
S
S
S
S
switching point28 mm ± 6
461.81
1.10±.236
switching point28 mm ± 6
461.81
1.10±.236
SW27
101.5
10
51.5
41
.394
1.64
2.03
3.97
.413
(1.06 in.)
SW27
101.5
10
51.5
41
.394
1.64
2.03
3.97
.197
(1.06 in.)
bay
onet
16S
ø5ø1
0.5b
ayon
et 1
6S
NR 60-W-…A
NR 60-F-…A
NR 60-F-…C NR 60-W-…D
switching point28 mm ± 6
461.81
1.10±.236
101.53.97
.413
ø10.
5
bayonetDIN 72585-A1-3.1-Sn/K1
ø27
SW27
10
62
.394
2.44
(1.06 in.)
switching point28 mm ± 6
461.81
1.10±.236SW27
101.5
10
51.5
41
.394
1.64
2.03
3.97
.413
(1.06 in.)
M27
x1
ø10.
5
SW27
M27
x1101.5
ø5switching point28 mm ± 6
10
46
51.5
41
.394
1.64 1.81
2.03
3.97
.197
1.10±.236(1.06 in.)
NR 60-W-…B
NR 60-F-…B
ø5switching point28 mm ± 6
10
46
.394
1.81
.197
1.10±.236SW27
441.73
(1.06 in.)
1114.37
ø27
612.40
cable FLR 3 x 0.75
This is a metric design and millimeter dimensions take precedence ( mm )inch
Level Sensor NR 60
04/05 161
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Connection diagramConnectors / Adapter
+
S
-
+
S
-
+
S
lamp connection relay connection
integral free-wheeling diode
CAUTION: Do not connect minus potential to signal terminalor plus potential to minus terminal!
IN 4007
Output signal LSS:
90° cover for corrugatedconduit NW10Y 306 499 01
ø25.8
42
ø25.8
33
90° cover for sheathedcableY 306 499 02
47.5 ø25.8
180° cover for sheathed cableY 306 500 01
ø5.9
7.8
SealY 306 502 01
31
ø18.
3
Jack for female connectorY 306 501 01
20.7
1.22
.720
.307
.232
.815
1.87 1.02
1.02
1.30
1.02
1.65
ø22
67
ø34
ø34
1.34
1.69
2.09
1.34
2.6443
53
65
ø34
39ø3
4
53
11/4"(SW32)
M 27x1
3/4" NPTF
15
27
2
10.0
79
.394
.591
.866
1.061.34
1.54
2.09
1.34
2.56
Connector M27x10Z051Z003012
Connector M27x1, 90°0Z051Z003011
Adapter0Z031Z010001
Bayonet 16S0Z051Z003010
Bayonet 16S, 90°0Z051Z003009
Female connector SWX 221 378 01 3-way
ø32.81.29
This is a metric design and millimeter dimensions take precedence ( mm )inch
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
Level Sensor NR 80
04/05 163
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Technical dataOrdering information
Options
Features
NR 80-...
Level Sensor NR 80 is designed to monitor a preset medium level in electrically non-conductive containers with a wall thickness up to approx. 5 mm. It is fitted outside the container.Suitable for water and other electrically conductive liquids with a highrelative dielectric constant εr.Available as MIN or MAX sensor.
Type No.NR80 level sensor for liquids
Voltage rating DC 6 - 36 V
Housing1 moulded housing (54.5 x 36 x 18 mm)
Output1 NPN transistor, low side switching2 PNP transistor, high side switching
Function (factory preset) MIN minimum sensorMAX maximum sensor
Cable (type: LVCC, AWG 24,3x0.2mm2)
Cable 2 m standard10 m max. (1)
NR80 - DC6-36 V - 1 1 - MIN - 2 m ordering example
(1) Available cable lengths: 2 m, 3 m, 5 m, 8 m, 10 m
Input voltage DC 6...36 Vor with power supply NG 03
Power consumption typically 5 mA
Output NPN transistor, low side switching, orPNP transistor, high side switching
max. load 100 mA, with free-wheeling diode
Voltage drop approx. 2 V
Ambient temperature 0 °C ... +70 °C
Medium temperature sensor not in contact with medium
Response delay approx. 60 ms
Switch point hysteresis vertically mounted:(depending on medium 12.5 mm max. (probe dia. = dia. of viscosity) active surface)
Degree of protection IP 54 housingto IEC 529/DIN 40050
Medium liquids
Pressure resistance N/A
Connection 3-wire AWG 24 cable
Reverse polarity protection in-built
Materialhousing ABS = acrylonitrile butadine styrene
Mounting method outside container (see dimension diagram)
Mounting attitude optional
Cable length 2 m standard, 10 m max.
Mass approx. 90 g
AC voltage ratings and relay outputs:only with power supply NG 03 (see page 177)
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
non-invasive mounting transistor output minimum or maximum sensor LED status indication very small physical size
mark to demonstrate compliance with applicable directive.
Level Sensor NR 80
04/05164
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Status indication factory preset for MIN or MAX
Dimensions
Schematic diagram
Connection diagram
ON
OFF
Minimum Maximum
medium level transistor output transistor outputmedium levelLED green LED green
load
load
ON
OFF
load
load
+
–
+
NPN PNP
–
load
load
load
load
+
–
+
NPN PNP
–3618
.5
54.5
3.5
69.5
62±0.3 2
18
6
7
15 28
12
.591 1.10
.472
2.44±.012
.138
.079
.276
.236
.709
.728
1.42
2.15
2.74
sensorelectrode
HF oscillator demodulator comparator output
adjustment
sensorelectrode
HF oscillator demodulator comparator output
adjustment
NPN transistor, low side switching
PNP transistor, high side switching
sensitivity adjustment22-turn adjustment screw without final stop
-
red
brown
black
+
external
free-wheeling diode
load
-
+
LED
NR 80-DC 6-36-11-...(NPN transistor)
NR 80-DC 6-36-12-...(PNP transistor)
sensitivity adjustment22-turn adjustment screw without final stop
-
red
brown
black
+
external
free-wheeling diode
load
-
+
LED
This is a metric design and millimeter dimensions take precedence ( mm )inch
Level Sensor NR 100
04/05 165
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Features
Technical data
Options
Accessories
NR 100-...
Level Sensor NR 100 is designed to monitor liquids, granules, and powder. It is especially suitable for aggressive media and foodstuffs. Available as MIN or MAX monitor.
Type No.NR100 Sanitary Level Sensor
Voltage ratingDC 24 V
Mounting methodSTD for use with compression nut
(to be ordered separately) G1A thread to DIN 13, part 6, ISO 228/11"NPT thread to ANSI B1.20.1
Probe and fitting materialB4 PTFE Teflon®
Function (factory preset)MIN minimum sensorMAX maximum sensor
Cable (type LVCC, AWG16,3x1.31 mm2)
standard without cable
NR100 - DC24V - G1A - B4 - MAX ... ordering example
Mating connector supplied with the product.
Input voltage DC 24 V ±25%or with power supply NG 03
Power consumption typically 30 mA
Output PNP transistor, high side switching,max. load max. 0.3 A (0.5 A short-time)
short-circuit and overload protectedwith free-wheeling diode
Voltage drop approx. 2 V
Ambient temperature -20 °C...+85 °C
Medium temperature -20 °C...+130 °C (max. +150 °C short-time)
Response delay approx. 1 s
Switching point hysteresis horizontally mounted:(depending on medium viscosity) 30 mm/32.5 mm max. (probe dia.)
Degree of protection IP 65 housing (with mating connector)to IEC 529/DIN 40050
Cable gland PG 9 (for 6.5 ... 8 mm cable dia.)
Pressure resistance 2 bar/29.4 PSI, with PTFE *)
Connection screw terminals max. 1.5 mm2 (AWG 16)
Reverse polarity protection in-built
Material probe PTFE *)fitting PTFE *)housing PTFE *)connector PBTP gv
Material spec. PTFE = teflon®
PolytetrafluorethylenPBTP gv = Polybutylene terephtalate
with glass fibre
Mounting method see dimension diagram
Mounting attitude optional
Cable length standard without cable300 m max.Observe voltage drop!
Mass approx. 180 g
*) Polyamide PA 12 to special order (pressure resistance 25 bar/367.5 PSI)
AC voltage ratings and relay outputs:only with power supply NG 03 (see page 177)
Ordering information
MIN or MAX sensor transistor output max. medium temperature +130 °C LED status indication sanitary probe
mark to demonstrate compliance with applicable directive.
0Z121Z000034 compression nut (for STD), consisting of- slotted nut- pressure spring- threaded bush
Level Sensor NR 100
04/05166
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Status indication factory preset for MIN or MAX
Dimensions Connection diagram
Schematic diagram
3
3
+
+
Minimum Maximum
medium level transistor output transistor outputmedium levelLED green LED green
3
3
+
+
short-circuit in the load circuit:
ON
OFF
ON
OFF
OFF OFF
external
4 = NC
LED
4
3
2
1
sensitivity adjustment20-turn adjustment screw without final stop
-
+
-+
suppression diode
load
LED
LED
sensorelectrode
HF-oscillator demodulator comparator output
adjustment
1.28
1.42
G1A
or
1"N
PT
SW32(1.26 in.) 3015
ø44.
5
45
ø30
80
approx. 145
56
female plugSW17
(.669 in.)
PG9
10
sleeve
ø32.
5
ø63PG9
ø64
slotted nut
3014
approx. 49 sensor
G1A or 1"NPT
STD (with compression nut)0Z121Z000034
threadedbush
spring
slotted nut
36
80
56
female plug44
45°
ø44.
5
drill-hole4 x 90°
velded joint
approx. 5.71
2.211.18.591
1.18
1.75
1.77.394
3.15
2.21
3.15
1.75
1.73
approx. 145approx. 5.71
1.18
2.52
.551
2.48
SW17(.669 in.)
approx.1.93
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
This is a metric design and millimeter dimensions take precedence ( mm )inch
Level Sensor NR 150
04/05 167
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Technical dataOrdering information
Options
Accessories
NR 150-...
Level Sensor NR 150 is suitable for liquids with low relative dielectricconstant εr (e.g. oil). With MIN/MAX selector switch.
Features
status indication by 2 LEDs suitable for general industrial applications recommended for oil or media with similar electrical conductivity min/max selector switch transistor output max. medium temperature +130 °C
Type No.NR150 Level Sensor
Voltage ratingDC 9-36 V short-circuit proof PNP transistor output
Mounting methodG3/4A thread to DIN 13, part 6, ISO 228/13/4"NPT thread to ANSI B1.20.1
Probe materialC Tefzel® (ETFE)
Fitting material2 stainless steel 1.4571/AISI 316 Ti
Connection (optional)(blank)standard with cable gland
type PGcable type: Ka type 1*)
B connector M 12 to DIN EN 60947-5-2cable type: Do + Ka type 24*)
NR150 -DC9-36V -G3/4A - C 2 - ... ordering example
*) cable to be ordered separately (see page 165)
AC voltage ratings and relay outputs:only with power supply NG 03 (see page 177)
Input voltage DC 9-36 Vor with power supply NG 03
Power consumption typically 15 mA
Output PNP transistor, high side switching,max. load max. 0.3 A (0.5 A short-time)
short-circuit and overload protected,with free-wheeling diode
Voltage drop approx. 2 V
Ambient temperature -20 °C...+85 °C
Medium temperature -20 °C...+130 °C (to +150 °C short-time)
Response delay approx. 0.1 s
Switching point hysteresis horizontally mounted:(depending on medium viscosity) 5 mm max. (probe dia.)
Degree of protection IP 65 housing (with mating connector)to IEC 529/DIN 40050
Cable gland PG 7
Pressure resistance 25 bar/367.5 PSI
Connection screw terminals max. 1.5 mm2 (AWG 16)
Reverse polarity protection in-built
Materialprobe ETFE fitting V4A, DIN 1.4571/AISI 316 Tiseal (O ring) Viton®
housing cover PA6-3-T
Material spec. ETFE = Tefzel®Ethylene TetrafluoromethyleneCopolymerisatePA6-3-T = Trogamide, transparent
Vibration 2 Hz ............25 Hz 1,6 mm(sinusoidal) 25 Hz ........400 Hz 4 g(IEC 60068-2-6) 400 Hz.....1330 Hz 5 g
1330 Hz...2700 Hz 10 g2700 Hz ..5000 Hz 25 g
Shock 50 g/11 ms(IEC 60068-2-27)
Mounting method screw in
Mounting attitude optional
Cable length 200 m max. (AWG 24)Observe voltage drop!
Mass approx. 220 g
0Z031Z000097 metal coupling if the sensor is to be used as an immersion sensor
mark to demonstrate compliance with applicable directive.
Level Sensor NR 150
04/05168
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Status indication: MIN or MAX
Dimensions Connection diagram
Schematic diagram
load
flashing
load
ON
OFF
OFF
ON
ON
LEDgreen red
Maximumselector switch pos. 2
+
Minimumselector switch pos. 1
medium level transistor output transistor outputmedium level
load
short-circuit in the load circuit:flashing
load
+
+
+
LEDgreen red
ON
OFF
OFF
ON
ON
external
selector switch
sensitivity adjustment15-turn adjustment screw without final stop
-
+
free -wheeling diode
load
LED
Connectorpins DIN EN 50044 or IEC 947M12x1 3pole
21- +
L- +
Cable gland
1brown
+4blackload
3blue
–
sensorelectrode
HF-oscillator demodulator comparator output
adjustment
20.2
SW32(1.26 in.)
SW32(1.26 in.)
approx. 5.91
.984
G3/
4A
ø14
6635
PG7without »B«
25
16
3/4"
NP
T
ø14
55
25
130
50
ø26.
7
13
Connector »B«
22
G3/
4A
M27
x1.5
45
PG 7
9
Metal coupling (for pipe extension)0Z031Z000097(to be ordered separately)
approx. 150
1.38
.630
2.60
.551
5.12
approx. 5.91
.98425
approx. 150
2.17
.795 2.60
.551
.984
1.05
.512
.866 .354
1.77
SW32(1.26 in.)
PG7without »B«
This is a metric design and millimeter dimensions take precedence ( mm )inch
NR 150 - Cable types
04/05 169
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Cable and cable connectorfor NR 150 with connection type B
M12 plug-in electrical connection for supply voltage and transistoroutput for supply voltage and transistor output.
Cable and cable connector Do + Ka type 24 - 5 m with connector to IEC60947-5-2, 3 pole
M12 and PUR insulated cable 3x0.34 mm2 (AWG 22)
Do + Ka type 24 - 5 m ordering example
Cable type 24
Technical data
Cable type 24Features: Protection degree IP 68 (only with
connector fitted)Resistant to chemicals and oils
Temperature range: -25 °C...+80 °C
Contact resistance: < 5 mΩCurrent carrying capacity: 4 A
Insulation resistance: > 109 ΩWithstand voltage: 2.0 kVeff. / 60 s
Ordering information for cable type 1for NR 150 with cable gland type PG7
Type No.Ka type 1 LVCC, 3x0.2 mm2 (AWG 24)
Available cable lengths... m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m,
25 m, 30 m ... 200 m (in 10 m steps)
Ka type 1 - 2 m ordering example
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
Level Sensor NR 160
04/05 171
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Features
Technical dataOrdering information
Accessories
NR 160-...
Capacitive Level Sensor NR 160 is designed to monitor liquids andpowders with high relative dielectric constant εr. With MIN/MAXselector switch.
Type No.NR160 Level Sensor
Voltage ratingDC 9...36V short-circuit proof PNP transistor output
Mounting methodG3/4A thread to DIN 13, part 6, ISO 228/13/4"NPT thread to ANSI B1.20.1
Probe materialA Polyamide® PA12-Gf
Fitting material2 stainless steel 1.4571/AISI 316 Ti
Connection (optional)(blank) standard with cable gland
type PGcable type: Ka type 1 *)
B connector M 12 to DIN EN 60947-5-2cable type: Do + Ka type 24 *)
NR160 - DC9...36V- G3/4A - A 2 - ... ordering example
*) cable to be ordered separately (see page 169)
Input voltage DC 9...36 Vor with power supply NG 03
Power consumption typically 17 mA
Output PNP transistor, high side switching,max. load max. 0.3 A (0.5 A short-time)
short-circuit and overload protectedwith free-wheeling diode
Voltage drop approx. 2 V
Ambient temperature -20 °C...+85 °C
Medium temperature -20 °C...+130 °C (max. +150 °C short-time)
Response delay approx. 0.1 s
Switching point hysteresis horizontally mounted:(depending on medium viscosity) 21.8 mm max. (probe dia.)
Degree of protection IP 65 housing to IEC 529/DIN 40050
Cable gland PG 7
Pressure resistance 25 bar/367.5 PSI
Connection screw terminals max. 1 mm2 (AWG 18)
Reverse polarity protection in-built
Material probe PA12-Gf fitting V4A, DIN 1.4571/AISI 316 Tisealing (O ring) Viton®
housing cover PA6-3-T
Material spec. PA12-Gf = Polyamide with glass fibrePA6-3-T = Trogamide, transparent
Vibration 2 Hz ............25 Hz 1.6 mm(sinusoidal) 25 Hz ........400 Hz 4 g(IEC 60068-2-6) 400 Hz.....1330 Hz 5 g
1330 Hz...2700 Hz 10 g2700 Hz ..5000 Hz 25 g
Shock 50 g/11 ms(IEC 60068-2-27)
Mounting method screw in
Mounting attitude optional
Cable length 200 m max. (AWG 24)Observe voltage drop!
Mass approx. 200 g
0Z031Z000097 metal coupling if the sensor is to be used as an immersion sensor
Options
AC voltage ratings and relay outputs:only with power supply NG 03 (see page 177)
status indication by 2 LEDs max. medium temperature +130 °C min/max selector switch transistor output recommended for granules, powder, water and other electrically
conductive media
mark to demonstrate compliance with applicable directive.
04/05172
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Status indication: MIN or MAX
Dimensions Connection diagram
Schematic diagram
transistor output
ONON
LEDgreen red transistor output
load
load
OFF ONOFF ON
flashing
ON
OFF
ON
Maximumselector switch pos. 2
Minimumselector switch pos. 1
medium level medium level
load
short-circuit in the load circuit:flashing
load
LEDgreen red
OFF
+
+
+
+
external
selector switch
sensitivity adjustment15-turn adjustment screw without final stop
-
+
free -wheeling diode
load
LED
Connectorpins DIN EN 50044 or IEC 947M12x1 3pole
21- +
L- +
Cable gland
1brown
+4blackload
3blue
–
sensorelectrode
HF-oscillator demodulator comparator output
adjustment
SW32(1.26 in.)
approx. 5.24
.984
G3/
4A
ø21.
8
5926
PG7without »B«
25
16
113
13
Connector »B«
22
G3/
4A
M27
x1.5
45
PG 7
9
Metal coupling (for pipe extension)0Z031Z000097(to be ordered separately)
approx. 133
1.02
.630
2.32
.858
4.45
.512
.866 .354
1.77
SW32(1.26 in.)
SW32(1.26 in.)
approx. 5.24
.984
ø21.
8
592625
16
113
approx. 133
1.02
.630
2.32
.858
4.45
3/4"
NP
T
PG7without »B«
This is a metric design and millimeter dimensions take precedence ( mm )inch
Level Sensor NR 160
NR 160 - Cable types
04/05 173
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
M12 plug-in electrical connection for supply voltage and transistoroutput.
Cable type 24
Technical data
Cable type 24 Features: Protection degree IP 68 (only with
connector fitted) Resistant to chemicals and oils
Temperature range: -25 °C...+80 °C
Contact resistance: < 5 mΩCurrent carrying capacity: 4 A
Insulation resistance: > 109 ΩWithstand voltage: 2.0 kVeff. / 60 s
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
Cable and cable connectorfor NR 160 with connection type B
Cable and cable connector Do + Ka type 24 - 5 m with connector to IEC60947-5-2, 3 pole
M12 and PUR insulated cable 3x0.34 mm2 (AWG 22)
Do + Ka type 24 - 5 m ordering example
Ordering information for cable type 1for NR 160 with cable gland type PG7
Type No.Ka type 1 LVCC, 3x0.2 mm2 (AWG 24)
Available cable lengths... m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m,
25 m, 30 m ... 200 m (in 10 m steps)
Ka type 1 - 2 m ordering example
Level Sensor NR 200
04/05 175
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Technical dataOrdering information
Options
Capacitive Level Sensor NR 160 is designed to monitor oil and mediawith low relative dielectric constant εr. With MIN/MAX selector switch.
Features
LED status indication max. medium temperature +85 °C min/max selector switch relay output switch delay, 1-60 s adjustable
Type No.NR200 Level Sensor
Voltage ratingAC115V 50/60 HzAC230V 50/60 HzAC240V 50/60 Hz
Mounting methodG3/4A thread to DIN 13, part 6, ISO 228/13/4"NPT thread to ANSI B1.20.1
Probe materialC Tefzel® (ETFE)
Fitting material2 stainless steel 1.4571/AISI 316Ti
NR200 - AC230V - G3/4A - C 2 ordering example
Input voltage AC 115 V +10% -15%AC 230 V +10% -15%AC 240 V +10% -15%
Power consumption < 4 VA
Output (relay) change-over contact
Max. loadswitching capacity DC 50 - 270 W
AC 2000 VA switching voltage DC 300 V/AC 250 Vswitching current 6 A
Ambient temperature -20 °C ... +70 °C
Medium temperature -20 °C ... +85 °C (to +125 °C short-time)
Response delay adjustable between 1 and 60 s
Switching point hysteresis horizontally mounted:(depending on medium viscosity) 5 mm max. (probe dia.)
Degree of protection IP 67 housing to IEC 529/DIN 40050
Cable gland PG 13.5 with 2 cable entries
Pressure resistance 25 bar/367.5 PSI
Connection screw terminals max. 1.5 mm2 (AWG 16)
Reverse polarity protection not required
Materialprobe ETFEfitting DIN 1.4571/AISI 316 Ti sealing (O ring) Viton®
housing ABShousing cover Polycarbonate
Material spec. ABS = Acrylonitrile butadine styreneETFE = Tefzel®Ethylene Tetrafluoromethylene Copolymerisate
Mounting method screw in
Mounting attitude optional
Mass approx. 480 g
Connection cable: only supplied without cable
NR 200-...
mark to demonstrate compliance with applicable directive.
Level Sensor NR 200
04/05176
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Status indication: MIN or MAX
Dimensions Connection diagram
Schematic diagram
LED greenmedium level relay contacts
2 1
3
2 1
3
LED green
Maximumselector switch pos. 2
Minimumselector switch pos. 1
medium level relay contacts
2 1
3
2 1
3
ON
OFF
ON
OFF
time delay22-turn adjustment screwwithout final stop
sensitivity adjustment15-turn adjustment screwwithout final stop
mains cable
selector switch: 1 - MIN2 - MAX
+
-
1
2
LED
123
relay
NL1
+
-
control cable
contact position de-energized
Standard cable gland insert: for 2 cablesInsert for 1 cable to separate order (accessory 0Z081Z000018)
sensorelectrode
adjustment
power supplyand relay output
HF oscillator demodulator comparator
SW 32(1.26 in.)
16
PG13.5
10580.5
82.5
G3/
4A
SW 32(1.26 in.)
ø14
66
35
20.2
ø14
22
ø26.
7
3/4"
NP
T
552.17
.551
1.05
.795
3.17
3.25
.866
.551
1.38
.630
2.60
4.13
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
This is a metric design and millimeter dimensions take precedence ( mm )inch
Power supply NG 03
04/05 177
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Technical dataOrdering information
Connection diagram
NG 03
The NG 03 power supply is suitable for E-T-A Level Sensors NR 60,NR 80, NR 100, NR 150 and NR 160. It has a relay output withadjustable switching delay which is controlled by the signal output ofthe sensor. Status indication is by green LED. Power failure and wirebreak are indicated in the same way as incorrect medium level (closedcircuit principle).
Features
DIN rail mounting relay output with adjustable switch-off delay LED status indication
Type No.NG 03 Power Supply for mounting on DIN rail 50 022-35
Input voltageAC 115 V 50/60 HzAC 230 V 50/60 HzAC 240 V 50/60 Hz
NG 03 - AC 230 V ordering example
Dimensions
123 45
70
73.5
20
2.89 2.76
4.84 1.77
.787
NR 60/LSSDC 9-36 V
+signal
DC 24 Vload0 VNG 03
687
redbrownblack
+signal NR 80/PNP
DC 6-36 V
DC 24 Vload0 VNG 03
697
redbrownblack
NR 80/NPNDC 6-36 V
+signal
DC 24 Vload0 VNG 03
687
redbrownblack
+load
DC24 V+load0 VNG 03 NR 160
DC 9-36 V
697
redbrownblack
mains
PNPload
NPNload
1
(+)DC 24 V
(-)0 V
NC
N L1
2 3
6 7 8 9 10
- +
LED
54DC24 V+load0 VNG 03 NR 150
DC 9-36 V
697
browngreenwhite
-
time delay
time delay270° adjustmentscrew withfinal stop
relay
Contact position de-energized.LED lights when relay is energized.
+load
DC24 V+load0 VNG 03 NR 100
DC 24 V
697
132
DC24 V+load0 VNG 03 NR 60/HSS
DC 24 V
697
+signal
Input voltage AC 115 / 230 V / 240 V 50/60 Hz+10 %/-15 %
Power consumption max. 4 VA
Output voltage DC 24 V
Output current 50 mA
Ambient temperature 0 °C...+70 °C
Degree of protection IP 20to IEC 529/DIN 40050
Connection screw terminalsmax. 2.5 mm2 (AWG 14)
Relay output potential-free change over contact120 W / 1200 VADC 100 V / AC 250 V / 5 A
Switching delay 1 - 60 s, adjustable
Mounting method on DIN rail 50 022-35
Mass approx. 290 g
mark to demonstrate compliance with applicable directive.
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
This is a metric design and millimeter dimensions take precedence ( mm )inch
FM 1-ST-CC (front panel mounted housing)144
96
M
4
82
92
140
mounting holeDIN 43700
FM 1-CC (rail-mounted housing)
100
75
56
60FM 1-FH-CC (surface mounted housing)
103
140
71
M16
140
125 M
M16ø4.5
mounting holes
2.95
3.94 2.21
2.36
4.06
5.51
2.80
5.514.92
.177
3.78
3.23
.157
3.62
5.51
5.67
This is a metric design and millimeter dimensions take precedence ( mm )inch
04/05 79
1
Electronic Flow Meter FM 1-CC
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Micro controller operated Flow Meter to monitor and display flowrates and temperature.Suitable for use with calorimetric or turbine-type monitoring heads.Either factory-preset or to be set by customer on site (various mediapossible, suitable for gear or lubricating oil up to viscosity classISOVG220).
Features Dimensions
Menu driven (keypads) LC display (2 x 16 digits) of:
- actual flow rate, volume flow or mass flow, medium temperature:
- bargraph status indication of limit contacts, actual flow rate/quantity or medium temperature
- directions for parameter assignment, configuration, diagnosis and error correction;
- base value indication Two scalable analogue outputs Peak memory (MIN + MAX) Two freely selectable limit contacts Quantity-related pulse output Versions for rail, front panel and surface mounting Higher accuracy as the exact characteristic curve of the
connected calorimetric monitoring head is recorded in thesoftware (= medium classification)
Ordering information FM 1-CC
TypeFM 1-CC Flow Meter, in rail-mounted housing (standard software version)FM 1-FH-CC Flow Meter, in surface mounted housing (IP 64)FM 1-ST-CC Flow Meter, in front panel mounted housing (IP 65)
Input voltageU1 DC 19...32 V or AC 24 V ±10 %
Signal outputsR2 2 relay outputs (2 limit values)T4 4 transistor outputs (2 limit value + 2 status, or 2 limit value +
1 status + 1 pulse output (menu-selected))Analogue outputsV1 0/1- 5 VV2 0/2-10 VC1 0/4-20 mA (self-powered, physically isolated)
Specification of mediumxxx
FM 1-CC - U1 R2 V1 - ... ordering example
The characteristic curve for water (CST and CSF-MK) has beenstored as standard.Please specify when ordering if we shall store a different curve(e. g. for air, or a turbine-head curve).
FM 1-CCfront panel mounted version surface mounted version
rail-mounted version
(5 % to 100 % of final value)
Electronic Flow Meter FM 1-CC
04/0580
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Technical data
(5 % to 100 % of final value)
Flow Meter FM 1-CC with CST/CSF/CSP with TSTcalorimetric monitoring heads turbine type sensors
General data
Media gases, liquids (oil etc.) gases, clean and particle-free liquids
Measuring functions flow rate/volume flow/mass flow/ flow rate, volume flowtemperature
Display 2 x 16-digit LC display
Parameter assignment, calibration by: keypads
Temperature range (electronic control unit) in circulating air 10 °C...+50 °C *)
Electrical data
Input voltage DC 24 V (19...32 V), AC 24 V ±10 % (50/60 Hz)
Power consumption DC 200 mA**) DC 110 mA
Analogue outputs (flow and temperature) 0/4-20 mA or 0/2-10 V or 0/1-5 V
(temperature N/A with TST heads)
Signal 2 relay outputs (2 limit values) 2 change over contacts AC/DC 50 V / 1 A / 50 W
outputs 4 transistor outputs (2 limit values + 2 status, or open collector outputs DC 36 V/150 mA/1.5 W
2 limits values + 1 status + 1 pulse output)
Flow measurement
Measuring range limit value if factory-preset water 0.05...3 m/s 0.1...5 m/s
(please specifiy) please enquire for oil air 0.1...20 m/s 1...20 m/s
Display range final value of span ± 10 %
(no negative display range)
Accuracy (5) Accuracy is a function of that of the reference typically approx. 2 % of measured value typically approx. 2 % of measured value
meter, of repeatability and the number of (e. g. in the measuring ranges indicated (e. g. in the measuring ranges indicated
setpoints. Accuracy also depends on the for FM 1, page 43) for FM 1, page 43)temperature and measuring range.
Repeatability (1) water ≤ 1 % of measured value ≤ 0.5 % of measured value
air ≤ 1 % of measured value ≤ 0.5 % of measured value
Temperature drift water 0.35 %/°K of final value none
(electronic control unit) (4) air 0.1 %/°K of final value none
Response delay water (2) 2.5 s 1 s
air (3) 3 s 1 s
Temperature measuring range -40 °C...+130 °C N/A
measurement accuracy ± 1 % of measuring range N/A
Mechanical data (electronic control unit)
Degree of protection rail-mounted: IP 20
surface mounted: IP 65
front panel mounted: IP 65
Materials rail-mounted: acrylic vinyl/styrene/polycarbonate; heat sink aluminium
surface mounted: aluminium/acrylic
front panel mounted: aluminium black coated; display polyester foil
Housing dimensions (LxWxH) see dimension diagrams (overleaf)
Mass rail-mounted: 485 g
surface mounted: 1250 g
front panel mounted 900 g
Cables voltage supply 3 x 0.75 mm2 (AWG 18)
to monitoring head LifYCY 4 x 2 x 0.2 mm2 (AWG 24) LifYCY 3 x 0.35 mm2 (AWG 22)
analogue outputs 2 x LifYCY 2 x 0.25 mm2 (AWG 24) 2 x LifYCY 2 x 0.25 mm2 (AWG 24)
limit value output 2 x LifYCY 3 x 0.38 mm2 (AWG 22) 1 x LifYCY 4 x 2 x 0.2 mm2 (AWG 24)
Max. cable length to monitoring head 200 m 200 m
*) With output C1 the max. admissible ambient temperature for the rail-mounted version is limited to +40 °C.**) With output C1, power consumption may be up to 300 mA ± 10 %. (1) of the set value, at constant temperature and flow conditions, and stable thermal conductivity.(2) Delay with the switch point set to 1 m/s and the flow at 2 m/s, after a sudden complete stop.(3) Delay with the switch point set to 10 m/s and the flow at 20 m/s, after a sudden complete stop.(4) Warm-up time to full accuracy: 15 minutes.(5) The accuracy values were determined under ideal conditions:
- symmetrical complete flow profile- correct mounting in the pipe- inlets and outlets according to EN ISO 5167-1
321 4321
XV XSK XTF XSF
XAS XAO XAH
321
87654321 87654321 87654321
10987654321
04/05 81
1
Electronic Flow Meter FM 1-CC
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Block diagram Connection diagram
Keyboard and display
Power supply AC/DC - DC/DC
SensorinterfaceCalorimetricmonitoringhead
SensorinterfaceTurbinetypesensor Micro controller
system
24 V AC ±10%DC 19 … 32 V
keypadsLC display2 x 16 digits
relay outputs: 2 limit valuestransistor outputs: 2 limit values +
1 error indication +1 busy or pulse output (software selected)
analogue outputscurrent or voltage
signal processingI/O - controllingmonitoringparameter memory
calorimetric monitoring headand turbine type sensor
Input voltage:
Keyboard/display:
User interface 1:
User interface 2:
Controller system:
Sensor interfaces:
Userinterface 1
Userinterface 2
Wire size: 0.14 mm2 to 1.5 mm2 single or stranded conductorStrip length: 6.5 mmClamping screw: M2 (nickel-plated brass)Contact material: pre-tinned tin bronze
XV: power supplyXSK: calorimetric monitoring headXTF: keyboard releaseXSF: turbine-type sensorXAS: not released for userXAO: analogue outputsXAH: signal outputs
Electronic Flow Meter FM 1-CC
04/0582
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
XAS XAO XAH
87654321 87654321 87654321
i C
UV
<36
V
inductance ofcounter drive
iC
tL tON t
UC
UV
t
Zener voltage
UC
tON - pick up timetL - time constant of break current
XAS XAO XAH
87654321 87654321 87654321
i L ≤
10 m
A
UV
CD
Electronic signal processing Electromagnetic pulse counter
FM 1-CC - Recommended connection of pulse output
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
Connection diagrams
calorimetricmonitoring head
blue
brown
yellow/ green
32
14
32
1
XVXS
KXT
FXS
F
XAS
XAO
XAH
32
1
8
76
54
32
1
8
76
54
32
1
8
76
54
32
1
109
87
65
43
21
(0V)
(+24 V)
GND
recommended:3x0.75 mm2
/LIM2LIM2COMLIM2SGNDL2
LifYCY 3x0.38 mm2 */LIM1LIM1COMLIM1SGNDL1
LifYCY 3x0.38 mm2 *
LifYCY 2x0.25 mm2 *
LifYCY 2x0.25 mm2 *
ANA2GNDANAO2SGNDA2SGNDA1ANA1GNDANAO1
DGNDSGNDFRINUBFR
brownblackwhitegreen
LifYCY 3x0.35 mm2
pinkgreyblack
redbluewhitebrowngreenyellow
LifYCY 4x2x0.2 mm2
R(Tdiff)-HIR(Tdiff)-LOSGND
ISAGNDR(Tref)-LOR(Tref)-HIR(HEIZ)-HIR(HEIZ)-LO * recommended
** Apply shield on one side only
input voltage
signal outputs
analogueoutputsC1, V1, V2 **
turbine type sensor
blue
brown
yellow/ green
pinkgreyblack
redbluewhitebrowngreenyellow
recommended:3x0.75 mm2
C/ +E/ -C/ +E/ -
C/+E/ -C/ +E/ -
32
14
32
1
XVXS
KXT
FXS
F
XAS
XAO
XAH
32
1
8
76
54
32
1
8
76
54
32
1
8
76
54
32
1
109
87
65
43
21
(0V)
(+24 V)
GND
LIM1LIM1LIM2LIM2 LifYCY 4x2x0.2 mm2 *BUSY/PULSEBUSY/PULSEERROR ERROR
LifYCY 2x0.25 mm2 *
LifYCY 2x0.25 mm2 *
ANA2GNDANAO2SGNDA2SGNDA1ANA1GNDANAO1
DGNDSGNDFRINUBFR
brownblackwhitegreen
LifYCY 3x0.35 mm2
LifYCY 4x2x0.2 mm2
R(Tdiff)-HIR(Tdiff)-LOSGND
ISAGNDR(Tref)-LOR(Tref)-HIR(HEIZ)-HIR(HEIZ)-LO
**
SGND
turbine type sensor
calorimetricmonitoring head
input voltage
signal outputs
analogueoutputsV1, V2, C1***
* recommended** E/ - emitter terminal C/ + collector terminal*** Apply shield on one side only.
FM 1-CC with relay outputs
FM 1-CC with transistor outputs
04/05 83
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
FM 1-CC - Monitoring head CST
Thread-mounted calorimetric monitoring head for Flow MeterFM 1-CC, suitable for general industry applications.
Description Thread-mounted calorimetric monitoring head
Features
Dimensions
CST-...
Suitable for installation in welding bushes Medium temperature -40 °C...+130 °C Material: stainless steel 1.4571/AISI 316 Ti,
or Hastelloy alloy C4 2.4610
Technical dataOrdering information
G1/2A
øA B
18 .709
mm inch
10 .394
mm inch
1/2-14NPT G1/2A
14 14
36
20
B
36
øA
SW27 SW27
round connector
.551
.787
1.42
1.06 in.
1.42
.551
1.06 in.
Type No.CST Thread-mounted monitoring head with calorimetric sensors
Process connection01 thread size G1/2A (FM 1-CC-standard)03 thread size 1/2"-14NPT11 thread size G1/2A (FM 1-CC special calibration)
MediumA airW waterS other media, e.g. oil (please enquire)
Material of areas exposed to mediumM1 stainless steel 1.4571/AISI 316 Ti (standard)M2 nickel-based alloy Hastelloy alloy C4 2.4610
Length of shank/threadL10 36 mm (standard)
Electrical connectionE10 round connector with tinned contacts
(plug and cable to separate order)CertificationT0 without certificate (standard)*)
Specification of mediumxxx
CST - 01 W M1 L10 E10 T0 - ... ordering example
*) for detailed information please see section 0.
Type of head thread-mounted
Nominal thread dia. G1/2A, 1/2"NPT
Length of shank 36 mm
Length of sensor 14 mm
Suitable for all media, depending onmaterial resistance
Temperatue range *) -40...+130 °C (of medium)
Temperature drift ±< 0.05 %/°K/measuring rangeof monitoring head (in the range between +20 °C and +80 °C)
Measuring ranges air: 0...20 m/swater: 0...3 m/s
Pressure resistance (1) 100 bar / 1470 PSI
Degree of protection connector(2): IP67
Material stainless steel 1.4571/AISI 316 TiHastelloy alloy C4 2.4610
Cable to LifYCY 4x2x0.2 mm2 (AWG 24)electronic control unit
This is a metric design and millimeter dimensions take precedence ( mm )inch
(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)
(2) with mating connector*) max. +85 °C in the connector area
Typ between calorimetric monitoring heads CST and FM 1-CC, FM 1-FH-CCDo + Ka type 15 PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18 silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15 - 2 m ordering example
Type between calorimetric monitoring heads CST and FM 1-ST-CCDo + Ka type 15-ST PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18-ST silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15-ST - 2 m ordering example
FM 1-CC - Cable types and accessories (CST)
04/0584
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Cable between Flow Meter FM 1-xxx and calorimetric monitoringhead type CST.
Connection to monitoring head by means of 8 pole round connector
Connection to FM 1-xxx by means of 10 pole clamping connector(XSK)
Cable types
Ordering information
Technical data
Cable type 15 and 15-STFeatures: highly flexible, paired, fully shielded,
electrical and thermal properties at +20 °C
Conductor resistance: < 92 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: max. 100 V AC
Withstand voltage: AC 800 V
Max. load: 0.5 A
Temperature range: -10 °C...+80 °C (processing and operation)-30 °C...+80 °C (transport and storage)
Cable type 18 and 18-STFeatures: non-halogenous, highly flexible, cold- and heat resistant,
paired, fully shielded, electrical and thermal propertiesat +20 °C
Conductor resistance: < 80 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: < 300 V AC
Withstand voltage: 1500 V / 50 Hz / 1 min
Max. load: 3 A
Temperature range: -60 °C...+200 °C
Do + Ka type 15 Do + Ka type 15-STDo + Ka type 18 Do + Ka type 18-ST
10 pole clamping connector for cable types 15 and 18(without cable, for individual wiring by customer)0Z112Z000167
10 pole clamping connector for cable types 15-ST and 18-ST(without cable, for individual wiring by customer)0Z112Z000205
24
G1/
2A
G3/
4A
SW301.18 .945
Reducing piecefrom G3/4 to G1/2Material: stainless steel 1.4571/AISI Ti 3160Z032Z000149
1.97
.709
ø18
50
8 pole round connector(without cable, for individual wiring by customer)0Z112Z003124
Accessories
Caution: Standard warranty cover will be invalidated if the correct E-T-A monitoring head/control unit connecting cable is notused.
This is a metric design and millimeter dimensions take precedence ( mm )inch
04/05 85
1
FM 1-CC - Monitoring head CSF-01
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Dimensions
Description Monitoring head CSF
CSF-01variable immersion depth
Extended calorimetric monitoring head for Flow Meter FM 1-CC,suitable for use in air-conditioning systems (variable immersion depth).
Caution: Fix with locking set 01 (see accessories).
Features
Medium temperature range: -40 °C...+130 °C Material: stainless steel 1.4571/AISI 316 Ti
Ordering information Technical data
14
M16
x0.7
5ro
und
con
nect
or
L14
ø18
monitoring head should bealigned in direction of flow(see arrow)
ø22
SW
20
Type Lmm inch
CSF-…L43… 190 7.48CSF-…L30… 300 11.81CSF-…L40… 400 15.75
.787
.866 .551
.551.709
TypeCSF Extended monitoring head with calorimetric sensors
Monitoring head design01 Monitoring head with variable immersion depth
MediumA air W water
Material of areas exposed to mediumM1 stainless steel 1.4571/AISI 316 Ti
Process connection00 without flange; see accessoires for cable gland**)
Length of shank/threadL43 190 mm (standard with process connection 00)
other lengths upon requestElectrical connectionE10 round connector with tinned contacts
(plug and cable to separate order)CertificationT0 without certificate standard *)
Specification of mediumxxx
CSF - 01 A M1 00 L43 E10 T0 - ... ordering example
*) for detailed information please see section 0.**) see next page.
Type of head push-in
Nominal shank dia. 18 mm
Length of shank 190 mm (standard)
Length of sensor 14 mm
Suitable for air (please enquire for other gases)
Temperature range*) -40... +130 °C / stainless steel(of medium)
Temperature drift ±<0.05 %/°K/measuring rangeof sensor (in the range between +20 °C and +80 °C)
Measuring ranges: air: 0...20 m/s atmospheric pressurewater: 0...3 m/s
Pressure resistance (1) 100 bar / 1470 PSI of sensor DIN 2401
Pressure resistance depending on threaded installation bushof installation 2 bar/16 bar (29.4 PSI/235.2 PSI), see next page
Degree of protection connector(2): IP67
Material stainless steel 1.457/AISI 316 Ti
Cable to LifYCY 4x2x0.2 mm2 (AWG 24)electronic unit
(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)
(2) with mating connector*) max. +85 °C in the connector area
This is a metric design and millimeter dimensions take precedence ( mm )inch
FM 1-CC - Cable types and accessories (CSF-01)
04/0586
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Cable between Flow Meter FM 1-xxx and calorimetric monitoringhead type CSF.
Connection to monitoring head by means of 8 pole round connector
Connection to FM 1-xxx by means of 10 pole clamping connector(XSK)
Cable types
Technical data
Cable type 15 and 15-STFeatures: highly flexible, paired, fully shielded,
electrical and thermal properties at +20 °C
Conductor resistance: < 92 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: max. 100 V AC
Withstand voltage: AC 800 V
Max. load: 0.5 A
Temperature range: -10 °C...+80 °C (processing and operation)-30 °C...+80 °C (transport and storage)
Cable type 18 and 18-STFeatures: non-halogenous, highly flexible, cold- and heat resistant,
paired, fully shielded, electrical and thermal propertiesat +20 °C
Conductor resistance: < 80 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: < 300 V AC
Withstand voltage: 1500 V / 50 Hz / 1 min
Max. load: 3 A
Temperature range: -60 °C...+200 °C
Do + Ka type 15 Do + Ka type 15-STDo + Ka type 18 Do + Ka type 18-ST
Ordering information
Typ between calorimetric monitoring heads CSF and FM 1-CC, FM 1-FH-CCDo + Ka type 15 PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18 silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15 - 2 m ordering example
Type between calorimetric monitoring heads CSF and FM 1-ST-CCDo + Ka type 15-ST PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18-ST silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15-ST - 2 m ordering example
04/05 87
1
FM 1-CC - Cable types and accessories (CSF-01)
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Accessories
Suitable up to 16 bar/1.6 M Pascal if used with stainless steel CSF-01 monitoring head.(Observe instructions for installation.)
Caution: Stainless steel ring is designed to bed into monitoring head.Pressure resistant to 25 bar/367.5 PSI.Teflon ring can only be used from 0 to 2 bar (29.4 PSI).
PG16 nickel-plated brass NPT3/4" moulded, black(standard) 0Z122Z0001310Z122Z000128
3/4"NPT
SW33
PG16O ring
SW301.18 1.30
10 pole clamping connector for cable types 15-ST and 18-ST(without cable, for individual wiring by customer)0Z112Z000205
10 pole clamping connector for cable types 15 and 18(without cable, for individual wiring by customer)0Z112Z000167
1.97
.709
ø18
50
8 pole round connector(without cable, for individual wiring by customer)0Z112Z003124
approx. 52
ø18
RT3
/4"
approx. 2.05
.709
Threaded installation bush Teflon sealing ring0Z122Z000196 0Z122Z000197
Locking set 010Z122Z000204
1 chain 4 x 32 DIN 5685 (approx. 1 m)2 catch for chain NG 53 clip with screw and nuts DN15 to DIN 11850
321
This is a metric design and millimeter dimensions take precedence ( mm )inch
FM 1-CC - Monitoring head CSF-03
04/0588
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description Flange-mounted calorimetric monitoring head
Flange-mounted calorimetric monitoring head for Flow Meter FM 1-CC.Recommended for food-processing (Tri-Clamp®).
CSF-03Tri-Clamp®
Features
Medium temperature range: -40 °C...+130 °C Material: stainless steel 1.4571/AISI 316 Ti
Dimensions
ø18
round connector
1415
.551
.591
.709
Ordering information Technical data
TypeCSF flange-mounted monitoring head with calorimetric sensors
Monitoring head design03 monitoring head with flange DIN 32676
MediumW waterS other media
Material of areas exposed to mediumM1 stainless steel 1.4571/AISI 316 Ti
Prozcess connection91 flange DIN 32676-Tri-Clamp® DN1
Length of shank/threadL90 15 mm (standard)
Electrical connectionE10 round connector with tinned contacts
(plug and cable to separate order)CertificationT0 without certificate (standard) *)
Specification of mediumxxx
CSF - 03 W M1 91 L90 E10 T0 - ... ordering example
*) for detailed information please see section 0.
Type of head flange-mounted monitoring head
Process connection DIN 32676 Tri-Clamp® DN 1
Shank dia. 18 mm
Length of shank 15 mm
Length of sensor 14 mm
Suitable for all media, depending on material resistance
Temperature range *) -40 °C...+130 °C(of medium)
Temperature drift ±< 0.05 %/°K/measuring rangeof monitoring head (in the range between +20 °C and +80 °C)
Measuring range water: 0... 3 m/s
Pressure resistance (1) 40 bar/588 PSI
Degree of protection connector(2) IP67
Material stainless steel 1.4571/AISI 316 Ti
Cable to LifYCY 4x2x0.2 mm2 (AWG 24)electronic control unit
This is a metric design and millimeter dimensions take precedence ( mm )inch
(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)
(2) with mating connector*) max. +85 °C in the connector area
04/05 89
1
FM 1-CC - Cable types and accessories (CSF-03)
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Cable between Flow Meter FM 1-xxx and calorimetric monitoringhead type CSF-03.
Connection to monitoring head by means of 8 pole round connector
Connection to FM 1-xxx by means of 10 pole clamping connector(XSK
Accessories
1.97
.709
ø18
50
10 pole clamping connector for cable types 15-ST and 18-ST(without cable, for individual wiring by customer)0Z112Z000205
8 pole round connector(without cable, for individual wiring by customer)0Z112Z003124
10 pole clamping connector for cable types 15 and 18(without cable, for individual wiring by customer)0Z112Z000167
Caution: Standard warranty cover will be invalidated if the correct E-T-A monitoring head/control unit connecting cable is not used.
This is a metric design and millimeter dimensions take precedence ( mm )inch
Cable types
Ordering information
Technical data
Cable type 15 and 15-STFeatures: highly flexible, paired, fully shielded,
electrical and thermal properties at +20 °C
Conductor resistance: < 92 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: max. 100 V AC
Withstand voltage: AC 800 V
Max. load: 0.5 A
Temperature range: -10 °C...+80 °C (processing and operation)-30 °C...+80 °C (transport and storage)
Cable type 18 and 18-STFeatures: non-halogenous, highly flexible, cold- and heat resistant,
paired, fully shielded, electrical and thermal propertiesat +20 °C
Conductor resistance: < 80 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: < 300 V AC
Withstand voltage: 1500 V / 50 Hz / 1 min
Max. load: 3 A
Temperature range: -60 °C...+200 °C
Typ between calorimetric monitoring heads CSF and FM 1-CC, FM 1-FH-CCDo + Ka type 15 PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18 silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15 - 2 m ordering example
Type between calorimetric monitoring heads CSF and FM 1-ST-CCDo + Ka type 15-ST PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18-ST silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15-ST - 2 m ordering example
Do + Ka type 15 Do + Ka type 15-STDo + Ka type 18 Do + Ka type 18-ST
FM 1-CC - Monitoring head CSP-01
04/0590
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
DescriptionMonitoring head CSP
Calorimetric plug-in type monitoring head for sensor adapter TP andflow meter FM 1-CC, suitable for use in technical plants for monitoringflow of various liquids and gases.
Features
CSP-01
Ease of installation Small physical size Medium temperature range -40°C...+130°C Material: stainless steel 1.4571/AISI 316 Ti Sealing: Viton O ring
TypeCSP plug-in type monitoring head with calorimetric sensors
Process connection01 plug-in type
MediumS all media, e.g. water (please enquire)
Material of areas exposed to mediumM1 stainless steel 1.4571/AISI 316 Ti (standard)
Length of shank/threadL05 18.2 mm (standard)
Electrical connectionE10 round connector with tinned contacts
(plug and cable to separate order)CertificationT0 without certificate (standard)*)
Specification of mediumxxx
CSP - 01 S M1 L05 E10 T0 - ... ordering example
*) for detailed information please see section 0.
Ordering information
Dimensions
ø20
ø18
18.2
14
64
8
ø24
retention slot
.945
.709
.315
.551
.717
2.52
.787
Technical data
Type of head plug-in type for sensor adapter TP
Shank diameter 18 mm
Length of shank 18.2 mm
Length of sensor 14 mm
Suitable for water, oil, air, compressed air, nitrogen, oxygen and other media (please enquire)
Temperature range *) -40...+130 °C(of medium)
Temperature drift ±< 0.05 %/°K/measuring rangeof monitoring head (in the range between +20°C and +80°C)
Measuring ranges air: 0...20 m/swater: 0...3 m/soil: 0...5 m/s
Pressure resistance (1) 100 bar/1470 PSI
Degree of protection connector(2) IP67
Material housing stainless steel 1.4571O-ring Viton
Cable to LifYCY 4x2x0,2 mm2 (AWG 24)electronic control unit
(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)
(2) with mating connector*) max. +85 °C in the connector area
This is a metric design and millimeter dimensions take precedence ( mm )inch
04/05 91
1
FM 1-CC - Cable types and accessories (CSP-01)
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Cable between Flow Meter FM 1-xxx and calorimetric monitoringhead type CSP.
Connection to monitoring head by means of 8 pole roundconnector
Connection to FM 1-xxx by means of 10 pole clamping connector(XSK)
Accessories
1.97
.709
ø18
50
10 pole clamping connector for cable types 15-ST and 18-ST(without cable, for individual wiring by customer)0Z112Z000205
8 pole round connector(without cable, for individual wiring by customer)0Z112Z003124
10 pole clamping connector for cable types 15 and 18(without cable, for individual wiring by customer)0Z112Z000167
This is a metric design and millimeter dimensions take precedence ( mm )inch
Caution: Standard warranty cover will be invalidated if the correct E-T-A monitoring head/control unit connecting cable is not used.
Cable types
Ordering information
Technical data
Cable type 15 and 15-STFeatures: highly flexible, paired, fully shielded,
electrical and thermal properties at +20 °C
Conductor resistance: < 92 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: max. 100 V AC
Withstand voltage: AC 800 V
Max. load: 0.5 A
Temperature range: -10 °C...+80 °C (processing and operation)-30 °C...+80 °C (transport and storage)
Cable type 18 and 18-STFeatures: non-halogenous, highly flexible, cold- and heat resistant,
paired, fully shielded, electrical and thermal propertiesat +20 °C
Conductor resistance: < 80 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: < 300 V AC
Withstand voltage: 1500 V / 50 Hz / 1 min
Max. load: 3 A
Temperature range: -60 °C...+200 °C
Typ between calorimetric monitoring heads CSP and FM 1-CC, FM 1-FH-CCDo + Ka type 15 PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18 silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15 - 2 m ordering example
Type between calorimetric monitoring heads CSP and FM 1-ST-CCDo + Ka type 15-ST PVC insulated cable, type LifYCY 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorDo + Ka type 18-ST silicone insulated cable, type 4x2x0.2 mm2 (AWG 24)
8 pole round connector + 10 pole clamping connectorAvailable cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 15-ST - 2 m ordering example
Do + Ka type 15 Do + Ka type 15-STDo + Ka type 18 Do + Ka type 18-ST
FM 1-CC - Sensor adapter TP / Ball valve BV
04/0592
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
DescriptionSensor adapter TP-... / Ball valve BV-...
TP-... BV-...
Ordering information
Accessories
Ordering information
Ordering information
TypeTP Sensor adapter with internal thread
Process connection/Nominal size01 DN 15 G1/2 internal thread length: 50 mm02 DN 20 G3/4 internal thread length: 64 mm03 DN 25 G1 internal thread length: 78 mm04 DN 32 G1 1/4 internal thread length: 94 mm05 DN 40 G1 1/2 internal thread length: 110 mm06 DN 50 G2 internal thread length: 138 mm
Material of the area exposed to mediumM1 stainless steel 1.4571/AISI 316Ti PN 315 bar M3 brass (not TP-03..) PN 25 barM5 red brass (only TP-03..) PN 16 bar
TP - 01 M3 ordering example
TypeTP Sensor adapter with welding nipples
Process connection/Nominal size01 DN 15 dia.d: 16 mm length: 50 mm02 DN 20 dia.d: 20 mm length: 70 mm03 DN 25 dia.d: 25 mm length: 80 mm04 DN 32 dia.d: 32 mm length: 100 mm05 DN 40 dia.d: 40 mm length: 110 mm06 DN 50 dia.d: 50 mm length: 140 mm
Material of the area exposed to mediumM1 stainless steel 1.4571/AISI 316Ti
Process connectionSA welded connection
TP - 01 M1 - SA ordering example
Description Ref. No.Blanking plug, brass, with O ring 0Z121Z000186Union nut, brass Y 306 901 01Blanking plug, stainless steel 1.4571/AISI 316 Ti, with viton O ring 0Z121Z000187Union nut, stainless steel Y 306 901 03
TypeBV ball valve with internal thread
Process connection/Nominal size03 DN 25 G1 internal thread length: 88 mm04 DN 32 G1 1/4 internal thread length: 100 mm05 DN 40 G1 1/2 internal thread length: 110 mm06 DN 50 G2 internal thread length: 131 mm
Material of the area exposed to mediumM3 nickel plated brass, Delrin seal
BV - 03 M3 ordering example
Features
Correct positioning of sensor Ease of sensor replacement Measuring point can be closed if not used Sensor adapter available as screw-in or welding type Ball valve also serves as a shutoff valve (both input and out
output)
Sensor adapters TP and BV facilitate correct positioning andexchange of CSP monitoring heads, FM 3 or FS 10 in pipes withprocess connection DN 15 ... DN 50.Ball valve BV enables pressure-free installation or removal of CSPmonitoring heads and Flow Meter FM 3 and FS 10 simply by closingthe input and output pipe. The measuring points are suited totemporary measurements; after completion of the measuring cyclethey can be closed by means of blanking plugs.
04/05 93
1
FM 1-CC - Sensor adapter TP / Ball valve BV
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
DimensionsG
t
L
t
SW ød
tt
L
SW
øD ød
A
H
ød G
t
SW
L
mmmm.591.591.591.591.591.591
.8391.061.331.671.902.37
mmTP-01M1-SATP-02M1-SATP-03M1-SATP-04M1-SATP-05M1-SATP-06M1-SA
273240505570
507080
100110140
151515151515
SWtdia. d
162025324050
DNType
152025324050
dia. D
21.326.933.742.448.360.3
L
mm in..591.787.9841.261.571.97
mm in..630.787.9841.261.571.97
mm in. in. in.1.972.763.153.944.335.51
in.1.061.261.571.972.162.76
273240505570
1.972.523.073.704.335.43
50647894
110138
.433
.472
.551
.591
.591
.748
SW
111214151519
tdia. d
162025324050
DNType
TP-01 …TP-02 …TP-03 …TP-04 …TP-05 …TP-06 …
152025324050
G
1/2"3/4"1"11/4"11/2"2"
L
mm in..591.787.9841.261.571.97
mm in..630.787.9841.261.571.97
mm in. mm in.1.061.261.571.972.162.76
mm in.in.
115115150150
2.322.563.033.35
59657785
AH
mm in.4.534.535.915.91
mm in.41505470
3.473.944.335.16
88100110131
.827
.945
.9451.10
SW
21242428
tdia. d
25324050
DNType
BV-03M3BV-04M3BV-05M3BV-06M3
25324050
G
1"11/4"11/2"2"
L
mm in..9841.261.571.97
mm in..9841.261.571.97
mm in. mm in.1.611.972.132.76
mm in.in.
TP-… Sensor adapter with internal thread
TP-..M1-SA Sensor adapter with welding nipples
BV-...M3 Ball valve with internal thread
Material stainless steel (-M1): PN 315 bar / 4630.5 PSIMaterial brass (-M3): PN 25 bar / 367.5 PSIMaterial red brass (-M5): PN 16 bar / 235.2 PSI
PN 315 bar / 4630.5 PSI
PN 25 bar / 367.5 PSI
SW = width across flats
This is a metric design and millimeter dimensions take precedence ( mm )inch
FM 1-CC - Monitoring TST-..HM2
04/0594
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
DescriptionMonitoring head with turbine-type sensor
TST-..HM2
Thread mounted monitoring head with turbine-type sensor for FlowMeter FM 1-CC. Recommended for high medium temperatureapplications. The unit consists of the turbine HM2 and a pre-amplifierwhich is connected with the HM2 by means of a 2 m cable.
Features
Medium temperature 0 °... +250 °C
Ordering information Technical data
TypeTST thread-mounted monitoring head with turbine-type sensor
Process connection01 G1/2A thread
Application range - Material of the area exposed to mediumHM2 +250 °C, air 20 m/s, water 5 m/s - stainless steel,
jewel bearing, hardened tips incl. 2 m connecting cable to the pre-amplifierLength of shank/threadL10 36 mm (standard)
Accuracy0 ±1 % of final value, ±3 % of measured value
(standard) Electrical connection to FM 1-CCE10 round connector with tinned contacts
(plug and cable to separate order)
TST - 01 HM2 L10 0 E10 ordering example
Type of head thread-mounted monitoring head
Nominal thread dia. G1/2A
Length of shank 36 mm
Length of sensor 19 mm
Suitable for water, oilair
Temperature rangeMedium: 0...+250 °C air *)Monitoring head (to medium): 0...+250 °C
(to electrical connection): 0...+250 °CPreamplifier: -10...+50 °C
Measuring range air: 1...20 m/swater, oil: 0.1...5 m/s
Pressure resistance (1) 10 bar/147 PSI(please enquire for higher pressure)
Degree of protection Monitoring head/cable IP68Monitoring head/cable connector IP67Preamplifier IP65
Material fitting stainless steel 1.4571/AISI 316Materials of wetted parts
- housing and turbine: chrome nickel/molybdenum steel VUA- bearings: jewel bearing sapphire
pivot bearing Nivadur
Cable to LifYCY 3 x 0.35 mm2 (AWG 22)electronic control unit
(1) Admissible operating pressure to DIN 2401, measured at max. temperature (= max. medium temperature)
(2) with mating connector*) Please observe that ice build up on the sensor at water temperatures ≤ 0 °C will destroy
the Sensor.
Dimensions of monitoring head TST-..HM2
SW 271.06 in.
G1/2A
ø11
to preamplifier
36
50
1.42
1.97
.433
approx. 2 m
This is a metric design and millimeter dimensions take precedence ( mm )inch
04/05 95
1
FM 1-CC - Turbine-type monitoring heads (TST)
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Advantages of mechanical flow rate sensingPreamplifier for monitoring head TST-..HM2
pipe
turbine
+10 %
0
error(at 10 m/s)
± 1.5 % systemtolerance band +25° -25°
-20 %
-10 %
+40° +30° +20° +10° 0 -10° -20° -30° -40°
streamline sensor
Streamline sensors are largely insensitive tooblique streaming (symmetrical to 0° line)
oblique streaming
Installation of monitoring head
Monitoring head with turbine-type sensor
Flow monitoring is often necessary in places that are not accessibleand where practical difficulties may prevent the correct alignment ofthe sensors with respect to flow direction. The special aerodynamicshape of the E-T-A sensors reduces this danger. The followingdiagram clearly shows that the “streamlined” E-T-A sensors have avery good alignment angle.
Wide medium temperature range: 0 °C to +250 °C, independent of temperature variations
short reaction time
Limitations: not suitable for media with solid particles can be overloaded only to a limited extent measuring signals depend on the viscosity of the medium shock-sensitive
Electronic flow meters with mechanical sensing rely upon a turbinemounted in the pipeline. The rotational speed of the turbine in theflowstream is proportional to the flow rate. Turbine rotation is remotelymeasured by an inductive proximity switch and transmitted as afrequency signal to the electronic control unit.
Mechanical sensing by means of turbine-type sensors isrecommended:
where temperatures may be above the temperature range of thecalorimetric heads (>130 °C)
where the media may change, where the properties (thermal conductivity) of the medium may
vary significantly, for media with air bubbles, where an immediate response to flow rate changes is required. Mind the viscosity when using with oil.
64
58
2
13
35
ground GND
output Ua
from monitoring head HM2
1.38 2.52
2.28
FM 1-CC - Cable type and accessories (TST-..HM2)
04/0596
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Cable type 16
Accessories
3 pole round connector(without cable, for individual wiring by customer)0Z112Z000138
4 pole clamping connector(without cable, for individual wiring by customer)Y 306 245 03
1.97.7
09
ø18
50
Description
Cable between turbine-type monitoring head TST and Flow MeterFM 1-CC.
Connection to monitoring head by means of 3 pole roundconnector
Connection to FM 1-CC by means of 4 pole clamping connector(XSK)
Technical data
Cable type 16Features: highly flexible, paired, fully shielded,
electrical and thermal properties at +20 °C
Conductor resistance: < 92 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: max. 100 V AC
Withstand voltage: 800 V ~
Max. load: 0.5 A
Temperature range: -10 °C...+80 °C (processing and operation)-30 °C...+80 °C (transport and storage)
Ordering information
Type between monitoring head TST and FM 1-CCDo + Ka type 16 PVC insulated cable, type LifYCY 3x0.35mm2, (AWG 22)
3 pole round connector + 4 pole clamping connector Available cable lenghts...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 16 - 2 m ordering example Caution: Standard warranty cover will be invalidated if the correct E-T-A monitoring head/control unit connecting cable is not used.
This is a metric design and millimeter dimensions take precedence ( mm )inch
04/05 97
1
FM 1-CC - Monitoring heads TST-..-AM1/WM1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Dimensions of monitoring heads TST-..-AM1/WM1
Description Monitoring heads with turbine-type sensor
Ordering information
Features
TST-...-AM1/WM1
Technical data
Thread-mounted monitoring head with turbine-type sensor for FlowMeter FM 1-CC.
Medium temperature range: TST-..WM1 water: +5... +80 °CTST-..AM1 air: -30...+140 °C
Type of head thread-mountedTST-AM1 TST-WM1
Length of shank 36 mm
Length of sensor 28.5 mm
Suitable for air water
Temperature range *) -30...+140 °C +5...+80 ° C(of medium)
Measuring range air: 1...20 m/swater: 0.1...5 m/s
Pressure resistance (1) 10 bar/147 PSI
Degree of Protectin connector (2) IP67
Material fitting stainless steel 1.4571/AISI 316Materials of wetted parts
- turbine housing PSU: TK-PSU, polysulfone, Udel- turbine: aluminium- bearings: jewel bearing Berivac (bronze-beryllium-alloy)
pivot bearing NivadurCable to LifYCY 3 x 0.35 mm2 (AWG 22)electronic unit
TypeTST thread-mounted monitoring head with turbine-type sensor
Process connection01 G1/2A thread
Application range - Material of the area exposed to mediumAM1 +140 °C, air 20 m/s; PSU, beryllium support, hardened tipsWM1 +80 °C, water 5 m/s PSU, beryllium support, hardened tips
Length of shank/threadL10 36 mm (standard)
Accuracy0 ±1 % of final value, ±3 % of measured value
(standard)Electrical connectionE10 round connector with tinned contacts
(plug and cable to separate order)
TST - 01 AM1 L10 0 E10 ordering example
G1/2A
SW 27
14
ø 38
36
58.5
ø12
round connector
.551
1.42
2.30
.472
1.06 in.
1.50
This is a metric design and millimeter dimensions take precedence ( mm )inch
(1) Admissible operating pressure DIN 2401, measured at max. temperature(= max. medium temperature)
(2) with mating connector*) max. +85 °C in the connector area
FM 1-CC - Turbine-type monitoring heads (TST)
04/0598
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Wide medium temperature range: water +5... +80 °Cair -30...+140 °C
independent of temperature variations short reaction time
Limitations: not suitable for media with solid particles can be overloaded only to a limited extent measuring signals depend on the viscosity of the medium shock-sensitive
Description
Monitoring head with turbine-type sensor
Electronic flow meters with mechanical sensing rely upon a turbinemounted in the pipeline. The rotational speed of the turbine in theflowstream is proportional to the flow rate. Turbine rotation is remotelymeasured by an inductive proximity switch and transmitted as afrequency signal to the electronic control unit.
Mechanical sensing by means of turbine-type sensors isrecommended:
where temperatures may be above the temperature range of thecalorimetric heads (>130 °C)
where the media may change, where the properties (thermal conductivity) of the medium may
vary significantly, for media with air bubbles, where an immediate response to flow rate changes is required.
pipe
turbine
connector(to electronic control unit)
fitting
+10 %
0
error(at 10 m/s)
± 1.5 % systemtolerance band +25° -25°
-20 %
-10 %
+40° +30° +20° +10° 0 -10° -20° -30° -40°
streamline sensor
Streamline sensors are largely insensitive tooblique streaming (symmetrical to 0° line)
oblique streaming
Installation of monitoring head
Flow monitoring is often necessary in places that are not accessibleand where practical difficulties may prevent the correct alignment ofthe sensors with respect to flow direction. The special aerodynamicshape of the E-T-A sensors reduces this danger. The followingdiagram clearly shows that the “streamlined” E-T-A sensors have avery good alignment angle.
Advantages of mechanical flow rate sensing
04/05 99
1
FM 1-CC - Cable type and accessories (TST-..AM1/WM1)
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Accessories
3 pole round connector(without cable, for individual wiring by customer)0Z112Z000138
4 pole clamping connector(without cable, for individual wiring by customer)Y 306 245 03
1.97
.709
ø18
50
Ordering information
Type between monitoring head TST and FM 1-CCDo + Ka type 16 PVC insulated cable, type LifYCY 3x0.35mm2, (AWG 22)
3 pole round connector + 4 pole clamping connectorLieferbare Kabellängen...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m,
30 m, 40 m, 50 m, 60 m, 70 m, 80 m, 90 m, 100 m, 110 m, 120 m, 130 m, 140 m, 150 m, 160 m, 170 m, 180 m, 190 m, 200 m
Do + Ka type 16 - 2 m ordering example
Cable type 16
Technical data
Cable type 16Features: highly flexible, paired, fully shielded,
electrical and thermal properties at +20 °C
Conductor resistance: < 92 Ω/km
Insulation resistance: > 200 MΩ/km
Operating voltage: max. 100 V AC
Withstand voltage: 800 V ~
Max. load: 0.5 A
Temperature range: -10 °C...+80 °C (processing and operation)-30 °C...+80 °C (transport and storage)
Cable between turbine-type monitoring head TST and Flow MeterFM 1-CC.
Connection to monitoring head by means of 3 pole roundconnector
Connection to FM 1-CC by means of 4 pole clamping connector(XSK)
This is a metric design and millimeter dimensions take precedence ( mm )inch
Caution: Standard warranty cover will be invalidated if the correct E-T-A monitoring head/control unit connecting cable is not used.
04/05100
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
04/05 131
1
Flow Monitor FS 10
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Features Connection diagram FS10
Ordering information
3
4black
brown
blue
1
FS 10
+ DC 24 V
loadmax. 500 mA
– minus
signal output
+UB
-UB
1brown
+4
blacksignal output
3blue
–
plug-in connector DIN EN 50044 or IEC 947M12x1 3 pole
Electrical Connection
flow rate of the medium in m/s
10001001010.10.01
liquid
gas
Flow rate ranges
FS 10-..
Compact single point flow monitor, MIN or MAX monitoring options,suitable for water, oil, air or media with similar thermal conductivities.With screw-in or plug-in type monitoring head for ease of installationand correct positioning.
If the flow rate falls below (MIN) or exceeds (MAX) the pre-adju-sted value, the signal output will be switched and the yellow LEDwill light.
wear-resistant compact design, with stainless steel 1.4571 monitoring head and housing
switch point steplessly adjustable by means of potentiometer status indication by green LED media temperature range –25°C...+100°C M12 plug-in electrical connection LED fault indication signal output with HighSide-FET output protected against short circuits and overloads
Flow monitor (calorimetric)FS10 flow monitor and integral compact housing
Power supplyU1 DC 24 V
Flow switch pointMINMAX
Process connection01 G1/2A (to DIN 3852-A), length 36 mm02 NPT1/2”-14, length 36 mm11 plug-in type (following DIN ISO 6149),
length 18.2 mmMediaA air, gasesW water, oil, liquids
Fitting materialM1 stainless steel 1.4571
Electrical connectionE12 M12x1, 3 pole
CertificationT0 without certificate *)
FS10 - U1 MAX 01 W - M1 E12 T0 ordering example
*) for detailed information please see section 0.
General data FS 10
Media liquids, gases
Monitoring function flow speed switch point (min/max)
fault indication LED (yellow)
signal output Power Fet, High Side switch, short circuit proof
max. load 500 mA, inductive load max. 100 mA
Temperature range media -25 °C...+100 °C
ambient -25 °C...+ 80 °C
Electrical data
Operating voltage UB DC 24 V (18...32 V)
Power consumption gases 28 mA ±5%
(without load) liquids 57 mA ±3%
Status indication LED (green)
Connection to DIN 50044 M 12 plug-in connection, 3 pole
Flow monitoring
Flow response level air 0.5...50 m/s with atmospheric pressure
adjustment water, oil 0.01...4.5 m/s
Repeatability (1) ≤ ±3 %
Response delay water typ. 2 sec (2)
air typ. 8 sec (3)
oil typ. 5 sec (2)
Switch point drift through temperature change of the medium approx. ±1.0 %/°C
Mechanical data
Type and size of plug-in following DIN ISO 6149
monitoring head screw-in G 1/2 A, NPT 1/2”
Pressure resistance of plug-in 100 bar
monitoring head screw-in 100 bar
Degree of protection IP67
Materials (standard) fitting (wetted) stainless steel 1.4571
sensor (wetted) stainless steel 1.4571
connection sensor/fitting laser welded
housing stainless steel 1.4571
M12 connector CuZn, nickel-plated
cap PA
O-ring Viton
Mass approx. 240 g
Flow Monitor FS 10
04/05132
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Technical Data ( ambient temperature TU = 25 °C, operating voltage UB = DC 24 V)
(1) of the set value, at constant temperature and flow conditions, and stable thermal conductivity(2) delay with the switch point set to 1 m/s and the flow at 2 m/s, after a sudden complete stop(3) delay with the switch point set to 10 m/s and the flow at 20 m/s, after a sudden complete stop
04/05 133
1
Flow Monitor FS 10
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
90 3.54
- + OON
Flow Switch
ø38
4036
14
SW27
DIN 3852form A
Adj.
G1/2"A
M12x1
Flow
dire
ctio
n
ø18
1.42
1.57
1.06
1.50
.551
.709
potentiometer for switch point adjustment
90.2
3.55
ø38
14
M12x1
Flow
dire
ctio
n
ø18
.717
2.28
1.50
.551
.709
- + OON
Flow Switch
58Adj.
cap nutG3/4"
O-ring 15.3x2.2(.602x.087) followingDIN ISO 6149material Viton®
locking slot
18.2
SW301.18
potentiometer for switch point adjustment
Dimensions of plug-in type process connection Dimensions of screw-in type process connection36
1.50
ø17.5
NPT1/2"-14
1020
ø38
14
SW27
90 3.54
- + OON
Flow Switch
40
Adj.
M12x1
Flow
dire
ctio
n1.
421.
57
1.06
.551
.689
potentiometer for switch point adjustment
.394
.787
Dimensions NPT thread
This is a metric design and millimeter dimensions take precedence ( mm )inch
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
FS 10 - Sensoradapter TP / Ball valve BV
04/05134
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Sensor adapter TP-.../Ball valve BV-...
TP-... BV-...
Description
Ordering information
Ordering information
TypeTP Sensor adapter with internal thread
Process connection/Nominal size01 DN 15 G1/2 internal thread length: 50 mm02 DN 20 G3/4 internal thread length: 64 mm03 DN 25 G1 internal thread length: 78 mm04 DN 32 G1 1/4 internal thread length: 94 mm05 DN 40 G1 1/2 internal thread length: 110 mm06 DN 50 G2 internal thread length: 138 mm
Material of the area exposed to mediumM1 stainless steel 1.4571/AISI 316Ti PN 315 bar M3 brass (not TP-03..) PN 25 barM5 red brass (only TP-03..) PN 16 bar
TP - 01 M3 ordering example
TypeTP Sensor adapter with welding nipples
Process connection/Nominal size01 DN 15 dia.d: 16 mm length: 50 mm02 DN 20 dia.d: 20 mm length: 70 mm03 DN 25 dia.d: 25 mm length: 80 mm04 DN 32 dia.d: 32 mm length: 100 mm05 DN 40 dia.d: 40 mm length: 110 mm06 DN 50 dia.d: 50 mm length: 140 mm
Material of the area exposed to mediumM1 stainless steel 1.4571/AISI 316Ti
Process connectionSA welded connection
TP - 01 M1 - SA ordering example
Features
Correct positioning of sensor Ease of sensor replacement Measuring point can be closed if not used Sensor adapter available as screw-in or welding type Ball valve also serves as a shutoff valve (both input and out
output)
Accessories
Ordering information
Description Ref. No.Blanking plug, brass, with O ring 0Z121Z000186Union nut, brass Y 306 901 01Blanking plug, stainless steel 1.4571/AISI 316 Ti, with viton O ring 0Z121Z000187Union nut, stainless steel Y 306 901 03
TypeBV ball valve with internal thread
Process connection/Nominal size03 DN 25 G1 internal thread length: 88 mm04 DN 32 G1 1/4 internal thread length: 100 mm05 DN 40 G1 1/2 internal thread length: 110 mm06 DN 50 G2 internal thread length: 131 mm
Material of the area exposed to mediumM3 nickel plated brass, Delrin seal
BV - 03 M3 ordering example
ø18
18.2
ø23.8
Welding set 050Z122Z000202
4
welded fittingstainless steel 1.4571
retention pin
cap nut
.157
.937
.717
.709
Sensor adapters TP and BV facilitate correct positioning andexchange of CSP monitoring heads, FM 3 or FS 10 in pipes withprocess connection DN 15 ... DN 50.Ball valve BV enables pressure-free installation or removal of CSPmonitoring heads and Flow Meter FM 3 and FS 10 simply by closingthe input and output pipe. The measuring points are suited to tempo-rary measurements; after completion of the measuring cycle they canbe closed by means of blanking plugs.
04/05 135
1
FS 10 - Sensoradapter TP / Ball valve BV
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
DimensionsG
t
L
t
SW ød
tt
L
SW
øD ød
A
H
ød G
t
SW
L
mmmm.591.591.591.591.591.591
.8391.061.331.671.902.37
mmTP-01M1-SATP-02M1-SATP-03M1-SATP-04M1-SATP-05M1-SATP-06M1-SA
273240505570
507080
100110140
151515151515
SWtdia. d
162025324050
DNType
152025324050
dia. D
21.326.933.742.448.360.3
L
mm in..591.787.9841.261.571.97
mm in..630.787.9841.261.571.97
mm in. in. in.1.972.763.153.944.335.51
in.1.061.261.571.972.162.76
273240505570
1.972.523.073.704.335.43
50647894
110138
.433
.472
.551
.591
.591
.748
SW
111214151519
tdia. d
162025324050
DNType
TP-01 …TP-02 …TP-03 …TP-04 …TP-05 …TP-06 …
152025324050
G
1/2"3/4"1"11/4"11/2"2"
L
mm in..591.787.9841.261.571.97
mm in..630.787.9841.261.571.97
mm in. mm in.1.061.261.571.972.162.76
mm in.in.
115115150150
2.322.563.033.35
59657785
AH
mm in.4.534.535.915.91
mm in.41505470
3.473.944.335.16
88100110131
.827
.945
.9451.10
SW
21242428
tdia. d
25324050
DNType
BV-03M3BV-04M3BV-05M3BV-06M3
25324050
G
1"11/4"11/2"2"
L
mm in..9841.261.571.97
mm in..9841.261.571.97
mm in. mm in.1.611.972.132.76
mm in.in.
TP-… Sensor adapter with internal thread
TP-..M1-SA Sensor adapter with welding nipples
BV-...M3 Ball valve with internal thread
Material stainless steel (-M1): PN 315 bar / 4630.5 PSIMaterial brass (-M3): PN 25 bar / 367.5 PSIMaterial red brass (-M5): PN 16 bar / 235.2 PSI
PN 315 bar / 4630.5 PSI
PN 25 bar / 367.5 PSI
SW = width across flats
This is a metric design and millimeter dimensions take precedence ( mm )inch
FS 10 - Cable type
04/05136
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
DescriptionCable type 24
Ordering informationTechnical data
M12 plug-in electrical connection for connection of supply voltageand switching output.
Cable and cable connectorDo + Ka type 24 - 5 m with connector to IEC60947-5-2, 3 pole
M12 and PUR insulated cable 3x0.34 mm2 (AWG 22)
Do + Ka type 24 - 5 m ordering example
Cable type 24Features: Protection degree IP 68 (only with
connector fitted) Resistant to chemicals and oils
Temperature range: -25 °C...+80 °C
Contact resistance: < 5 mΩCurrent carrying capacity: 4 A
Insulation resistance: > 109 ΩWithstand voltage: 2.0 kVeff. / 60 s
Issue D
1
USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510
General data SU 1003 SU 1004Compact housing Single Point Flow Monitor Dual Point Flow MonitorMedia liquids, gases liquids, gasesMonitoring flow rate 1 switch point (MIN or MAX) 1 or 2 switch points (MIN and MAX)
function medium temperature 1 switch point (MAX)Display flow rate 1 dual color LED 1 or 2 dual color LED’s (red/green)
medium temperature 1 dual color LEDTemperature medium and monitoring head -25°C...+70°C (-13°F...+158°F) -25°C...+70°C (-13°F...+158°F)range electronic control unit -25°C...+50°C (-13°F...+122°F) -25°C...+50°C (-13°F...+122°F)Electrical dataInput voltage AC 230, 115, 24 V 50/60 Hz +10%,-15%
DC 24 V ±20 %Power consumption approx. 1.2 VA approx. 1.5 VARelay outputs flow rate 1 change over contact 1 or 2 change over contacts
AC 250 V / DC 30 V, 5 A AC 250 V / DC 30 V, 5 Amedium temperature 1 change over contact
AC 250 V / DC 30 V, 5 AFlow monitoringFlow response level adjustment with gases: 0.5 m/s...50 m/s (2 to 160 FPS)(steplessly by means of a potentiometer) with liquids: 0.01 m/s...2 m/s (0.03 to 7 FPS)Repeatability (1) ± 10 %Response delay (2) 2 s with water, 4 s with oil, 7 s with air
selectable delay (no delay, 60 s switch-on delay or 10 s change over delay)
Switch point drift through temperature change of the medium approx. ±0.7 %/°CMechanical dataType and size of monitoring head 1/2"NPT, 3/4"NPT, 1"NPTPressure resistance of monitoring head 250 bar/3675 PSIEnvironmental monitoring head IP67
protection electronic control unit explosion proof FM, CSA approved housingfitting/sensor support stainless steel 1.4571/AISI 316Ti
Materials sensor stainless steel 1.4571/AISI 316Tisealing nickel based solder DIN 8513-L-Nielectronic control unit Epoxy painted cast aluminium
Housing electronic control unit 4.5" x 4.5" x 3.5"dimensionsCable length standard without
max. length 100 m
(1) of the set value, at constant temperature and flow conditions, and stable thermal conductivity.(2) Delay with the switch point set to 1 m/s and the flow at 2 m/s, after a sudden complete stop.
Flow Monitors SU 1003 / SU 1004
Technical data
119 a
Description
Single point flow monitor (SU 1003), dual point flow monitor (SU 1004), withchange over MIN/MAX monitoring function, suitable for water, oil, air and mediawith similar thermal conductivities. With either no delay, or with a 60 secondsswitch on delay or 10 seconds change over delay (SU 1003).
Features
Adjustable to wide range of flow ratesNo moving parts in the flow streamOperation largely independent of pipe diameterLED Status indicationFast response timeMIN or MAX switch pointSuitable for all media (water, oil and air)Explosion proof and weatherproof SU 1003 / SU 1004
1
Issue D USA (847) 827-7600 - www.e-t-a.com - CANADA (905)-764-9510
Ordering information
Flow Monitors SU 1003 / SU 1004
(see
no
te 2
)
119 b
number of feet (Example: 1-6=6" PVC Cable)
* Field Selectable** Time delay is inactive in standard unit*** Type SU 1003 only****Type SU 1004 only. Field Selectable. Setpoint ”B“ Only. Standardfactory setup is Setpoint ”A“ = low setpoint for flow (fixed) &
Setpoint ”B“ = high setpoint for flow. Setpoint ”B“ can bechanged by jumper selection to be a temperature switch.
Flow Monitor SU 1003 Single Point Flow Monitor SU 1004 Dual Point Flow Monitor
01 Explosion proof for Class 1, Div. 1, Groups B, C and D, NEMA 4xWeatherproof. FM/CSA Approved Housing with WindowPower Input03 115 V AC04 24 V AC/DC05 230 V AC
Process connection (see note 2)050 1/2" MNPT (Standard)075 3/4" MNPT100 1" MNPTF Mounting Configuration (Flanges, Spools, Tees,
Removable Probe Assembly) - Please Specify(see note 1)Sensor Material (see note 1)SS 316 Ti, 1.4571HC HastelloyB PVDF Plastic with Gold Plated Tips
(3/4"NPT only, not explosionproof)Insertion length
1/2"MNPT 3/4"MNPT 1"MNPT01 1" 1" N/A02 2" 2" 1"04 4" 3" 3"06 6" 5" 5"08 8" 7" 7"10 10" 9" 9"00 Specify length in inches
Options0 No Selection1 Remote Electronics5*** 60 Sec. ”Power On" Relay
Delay to ”De-energize" */**6*** 10 Sec. ”Setpoint Switching"
Relay Delay to ”De-energize" */**7*** Relay De-energized on
”Flow" Condition8*** Relay De-energized on
”No Flow" Condition (Standard)9 1/2"NPT Conduit Adaptor10**** Temperature switch Option11 SS Tag (Specify Markings)12 Reverse Front Cover Plate
OrientationExtension wire (see note 3)0 No Selection1 PVC2 Teflon
SU 1003 - 01 - 03 - 050 - A - 01 - 5/8/11 - 0 ordering example
Notes:1.) If mounting, switch configuration or sensor material is other than
shown in the ordering information please consult factory forpricing and availability.
2.) A Pipe thread size adaptor is supplied for 3/4"MNPT and1"MNPT process connections as shown in the chart in the abovedimension drawing and is used with a Process Connection Code”050“ probe in all cases. A Sensor Material Code ”A“ probe isshown in the above drawing. If insertion length is otherthan noted, please specify. Insertion length = from tip of probe tothe start of the insertion threads or flange.
3.) For optional remote electronics only. Enter code followed by
Issue D
1
USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510
Dimensions Connection diagram
Flow Monitors SU 1003 / SU 1004
medium switch
MIN/MAX change over switch
flowpotentiometer
LEDMIN/MAX
mai
ns
rela
you
tput
s
L N
IIIIII
V1 V2
MAXMIN
1 2 3 4 5
G R
medium switch
selector switch for 2nd function
flowpotentiometer
LED
mai
ns
rela
you
tput
s
L N
IIIIII
flow (MAX)temperature
1 2 3 4 5 6 7 8
G R
MIN MAX
R G
oilairwater
MIN MAX
SU 1003
oilairwater
SU 1004
119 c
0.5
“B”
4.5
4.5
Front view Side view
3/4"NPT Hub
GR
GR
-+
-+
3.5
“C” “A”
3/4"NPT hub
Insertion length “C”
01
02
04
06
08
10
1.0" 1
2.0" 1
4.0" 1
6.0" 1
8.0" 1
10.0" 1
1.0" 1
2.0" 1
3.0" 2
5.0" 2
7.0" 2
9.0" 2
N/A
1.0" 3
3.0" 3
5.0" 3
7.0" 3
9.0" 3
Explosion-proof/weatherproof housing
Probetips
1/2"FNPT to 3/4" MNPT adaptor or1/2"FNPT to 1" MNPT adaptor(See chart below)
# 1.0" & 2.0" insertion lengths## 3.0" thru 9.0" insertion lengths1 No size adaptor2 1/2"FNPT to 3/4"MNPT size adaptor
supplied3 1/2"FNPT to 1"MNPT size adaptor
supplied
“B”Code Process connection “A”
050
075 #
075 ##
100
1/2" MNPT3/4"MNPT
3/4"MNPT
0.7"
0.9"
0.7"
0.7"1" MNPT
Miniature Flow Monitor SW 112 for air and inert gases
04/05 137
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
General data SW 112
Media air, inert gases
Monitoring function flow rate 1 switch point (MIN)
Display flow rate 1 LED (green)
Temperature medium and monitoring head -20 °C...+60 °C
range electronic control unit -20 °C...+50 °C
Electrical data
Input voltage AC 24 V +10 %/-15 % / DC 19 ... 32 V
Power consumption approx. 20 ... 50 mA
Relay outputs flow rate 1 NO contact, AC/DC 24 V - 0.7 A
Max. load
Flow monitoring
Flow response adjustment (steplessly by means of a potentiometer) 0.5 m/s...20 m/s
Repeatability (1) ± 1 %
Response delay (2) < 1 s
Switch point drift through temperature change of the medium approx. ±0.25 %/°C
Delay on switch-on 18 s (contacts closed)
Mechanical data
Type and size of monitoring head ø18 mm for mounting flange or PG
Pressure resistance of monitoring head 1 bar/14.7 PSI (relative pressure)
Environmental protection monitoring head IP60 between medium and control unit
electronic control unit IP40
fitting/sensor support polyamide, aluminium
Materials sensor ceramics, glass-passivated
electronic control unit PVC/polyamide
Housing dimensions electronic control unit ø18 mm, 162 mm long
Mass 84 g
Cable length standard 2 m (3 x 0.20 mm2/AWG 24)
max. length 25 m
(1) of the set value, at constant temperature and flow conditions, and stable thermal conductivity.(2) Delay with the switch point set to 5 m/s and the flow at 10 m/s, after a sudden complete stop.
The Miniature Flow Monitor SW 112 operates on the provencalorimetric principle and is designed to operate with air or inertgases. Self-contained sensor head with integral electronic circuitry.
Technical data
SW 112 (without mounting flange)
Description
Features
Adjustable to wide range of flow rates No moving parts in the flow stream Operation largely independent of pipe diameter LED status indication Relay output for flow Fast response time Suitable for air and inert gases Mounting by flange (part of product) or PG cable gland (accessory)
Miniature Flow Monitor SW 112 for air and inert gases
04/05138
1
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Ordering information Dimensions
brown
2000+5012
ø32
LED
potentiometer
37 46
ø4.2 ø14
162
ø18 4
15
ø24
red
signal +black
+
–
View A
A
indication of flow direction
adjustable mounting flange(part of product)
3x0.4 mm2 cable
.472 78.74±1.97
.709
1.46
1.81
.165
.945
.157
.591
1.26
.551
6.38
Connection diagram
_~
24 V AC/DC
+ [ - ]
- [ + ]
red
brown
black
=
Flow contacts closed, LED ONNo flow or under limits (shown above): contacts open, LED OFF
Accessories
PG16
PG16 nickel-plated brass0Z122Z000128
SW30
NPT3/4" moulded, black0Z122Z000131
O-Ring3/4"NPT
SW331.18 1.30
Flow ranges
flow rate of the medium in m/s
10001001010.10.01
air
Switch point hysteresis
1.00
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
Hys
tere
sis
(con
tact
s cl
osed
) in
m/s
0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00
switch point (contacts open) at m/s
Miniature Flow MonitorSW112-RE Flow Monitor for air/inert gases, with relay output,
incl. mounting flangeInput voltageAC/DC 24 V
Cable length2 m standardor specify length up to 25 m max.*
SW112-RE AC/DC24 V - 2 m ordering example
* Available cable lengths: 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m and 25 m
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
This is a metric design and millimeter dimensions take precedence ( mm )inch
Issue D 121
1
USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510
General data SW 118 SW 119Single Point Flow Monitor Single Point Flow Monitorin a compact housing for surface mounting
Media liquids, gases liquids, gasesMonitoring flow rate 1 switch point (MIN or MAX) 1 switch point (MIN or MAX)function wire break/circuit failure standardDisplay flow rate 1 dual color LED 1 dual color LEDTemperature medium and monitoring head -25 °C...+70 °C/-13 °F...+158 °F -25 °C...+100 °C/-13 °F...+212 °Frange electronic control unit -25 °C...+50 °C/-13 °F...+122 °F -25 °C...+50 °C /-13 °F...+122 °FElectrical dataInput voltage AC 230/115/24 V 50/60 Hz AC 230/115/24 V 50/60 Hz
+10 %, -15 % +10 %, -15 %DC 24 V ±10 % DC 24 V ±10 %
Power consumption approx. 1.2 VA approx. 1.2 VARelay outputs flow rate 1 change over contact 1 change over contactMax. load AC 250 V/DC 30 V, 5 A AC 250 V/DC 30 V, 5 A
Overvoltage category II Overvoltage category IIFlow monitoringFlow response level adjustment with gases: 0.5 m/s...50 m/s with gases: 0.5 m/s...50 m/s
1.64 FPS...164 FPS 1.64 FPS...164FPS(steplessly by means of a potentiometer) with liquids: 0.01 m/s...2 m/s with liquids: 0.01 m/s...2 m/s
0.3 FPS...6.56 FPS 0.3 FPS...6.56 FPSRepeatability (1) ± 3 % ± 3 %Response delay (2) 2 s with water, 4 s with oil, 7 s with airSwitch point drift through temperature change of the medium approx. ± 0.7 %/°C approx. ± 0.7 %/°CMechanical dataType and size of monitoring head G1/2A 1/2"NPT G1/2A, 1/2"NPTPressure resistance of monitoring head (3) 100 bar / 1470 PSI 100 bar / 1470 PSIDegree of monitoring head IP67 IP67 (connector)protection electronic control unit IP65 IP65
fitting stainless steel 1.4571/V4A/AISI 316Ti stainless steel 1.4571/V4A/AISI 316Ti
Materials sensor stainless steel 1.4571/V4A/AISI 316Ti stainless steel 1.4571/V4A/AISI 316Ti
seals lasered laseredelectronic control unit polycarbonate polycarbonate
Housing electronic control unit 80.5 x 82.5 x 68.5 mm 120 x 80 68 mmdimensionsCable length to standard – 2 m (6x0.14 mm2)monitoring head max. length – 100 m(1) of the set value, at constant temperature and flow conditions, and stable thermal conductivity.(2) Delay with the switch point set to 1 m/s and the flow at 2 m/s, after a sudden complete stop.(3) Admissible operating pressure to DIN 2401, measured at the max. admissible temperature (= max. medium temperature)
SW 118 SW 119
Description
Adjustable to wide range of flow ratesNo moving parts in the flow streamOperation largely independent of pipe diameterLED status indicationFast response timeMIN or MAX switch pointSuitable for all media (water, oil, and air)Medium temperature range: SW118: -25...+70°C; SW119: -25...+100°C
Features
Single point flow monitors with change over MIN/MAX monitoringfunction, suitable for water, oil, air, and media with similar thermalconductivities (selectable by means of a medium switch). With either nodelay, or with a 60 s switch-on delay or 10 s change over delay.
Single Point Flow Monitors SW 118 / SW 119
Technical data
1
122 Issue D USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510
Dimensions SW 118
Connection diagram SW 118
Flow ranges
Electronic Control Unit
Monitoring Head
Ordering information SW 118
SW 119 – Cable and cable connector
Ordering information SW 119
Single Point Flow Monitors SW 118 / SW 119
2.66 36
NPT 1/2"
20
80.5
82.5
20
PG13.5 20
SW271.06 in.
55
1436
67.5
G 1/2A 14
67.5
3.17
3.25
.787
.551
1.42
2.66
2.17
.787
.551
1.42 .7
87
medium switchMIN/MAX change-over switch
flowpotentiometer
LEDMIN/MAX
L N
IIIIII
V1 V2
MAXMIN
1 2 3 4 5
G R
mains relayoutputs
1 2 3 4 5
MIN or MAX
relay not energized (LED red)
L N 0 I
0 = medium to be monitored is in the unadmissible rangeI = medium to be monitored is in the operating range
flow rate of the medium in m/s
10001001010.10.01
liquid
gases
This is a metric design and millimeter dimensions take precedence ( )mminch
Fitting size MK G1/2A (standard) MK 1/2"NPT
MaterialST11 only NPT threadST12 only G1/2A (standard)
MK G1/2A - ST12 ordering example
Single Point Flow Monitor SW 119 for surface mounting, with separate monitoring head
Input voltageAC 230 V 50/60 Hz (standard)AC 115 V 50/60 HzAC/DC24 V (AC: 50/60 Hz)
SW 119 - AC230V ordering example
Cable and plug between monitoring head and control unit Do + Ka type 2 7pole round connector, PVC insulated cable type
LiYCY 6x0,14 mm2 RAL 7032Available cable lengths...m 2 m, 3 m, 5 m, 8 m, 10 m, 15 m, 20 m, 25 m, 30 m,
40 m, 50 m, 60 m, 70 m, 80 m, 90 m and 100 m
Do + Ka type 2 - 2 m ordering example
Single Point Flow Monitor SW 118 in a compact housing, with integral monitoring head
Input voltageAC 230 V 50/60 Hz (standard)AC 115 V 50/60 HzAC/DC24 V (AC: 50/60 Hz)
Process connectionMK G1/2A (standard)MK 1/2"NPT
Monitoring head materialST11 only NPT threadST12 only G1/2A (standard)
SW 118 - AC230V - MKG1/2A - ST12 ordering example
Issue D 123
1
USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510
Connection diagram SW 119
Single Point Flow Monitors SW 118 / SW 119
Dimensions Electronic Control Unit SW 119 Dimensions Monitoring Head SW 119
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
sensors rotated by 90°
sensors rotated by 90°
cable
cable
SW 271.06 in.
SW 271.06 in.
3614
G 1
/2 A
20
3614
NP
T 1/
2"
.551 1.42
.551 1.42
.787
108.
5
PG9
50
120
20
20
23
80
PG9
ø4.2
4
20
55
1.97 .787
4.27 4.
72.7
87
.157
.165
.787
2.173.15
.906
mains relayoutputs
1 2 3 4 5
MIN or MAX
relay not energized (LED red)
L N 0 I
0 = medium to be monitored is in the unadmissible rangeI = medium to be monitored is in the operating range
medium switch
MIN/MAX change-over switch
flowpotentiometer
LEDMIN/MAX
mains
relayoutputs
LN
I III II
V1 V2
MAX
MIN
13 14
15
16 1
7 18
19
1 2 3 4 5yellowgreenbrown
shield
whitegrey
black
monit
oring
head
GR
54
321
6
This is a metric design and millimeter dimensions take precedence ( )mminch
TypeTLS100 tube sensor (DC 9...36 V)
MediaW water
Process Connection/tube diameterA10 mounting clips /10 mm
Function A Minimum OC (open circuit principle)B Maximum OC (open circuit principle)C Minimum RC (closed circuit principle)D Maximum RC (closed circuit principle)
Output signalL LSS (minus switching)H HSS (plus switching)
Response delay0 100 ms
Cable ConnectionA Cable (type: LVCC, AWG 24, 3 x 0,2 mm2)
Cable length 2 m (standard) (1)
TLS100 - W A10 A L 0 - A 2 m ordering example
(1) Cable lengths available: 0.1 m, 1m, 2 m, other lengths upon request.
Tube sensor TLS100
157
2
04/05 Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Technical data (TUambient temperature= 25°C, operating voltage UB = DC 24 V)
TLS100
Ordering information
WENThe TLS100 tube sensor works on the capacitive measuring principleand detects the presence of a liquid in a plastic tube. These plastictubes may also be mounted as a by-pass on a compensator in orderto signal the required medium level in containers.
The sensor is simply snapped onto the tube at the ideal level of themedium and provides versatile usage for a wide range of applicationsin medical equipment, the food stuffs industry etc.
The sensor can additionally be fixed by means of the two mountinglugs to ensure a tight fit on the tube.
Operating dataOperating voltage UB DC 12/24 V (DC 9...36 V)
Power consumption typically 8 mA
Output current max. 1 A, low-side switching, short-circuitproof and overload protected over the entire temperature range, with free-wheeling diode
Voltage drop at outputtransistor < 200 mV at 1 A
Response delay of output signal typically 100 ms (red LED lighted when
output is switched)
Reverse polarity protection fitted between plus and minus poleShort circuit and overload protection reset of output and autoreset after
remedy of short circuit
Switching point with vertical mounting position adjustable by means of potentiometer,
ideally between the two mounting clips
Visual indication red LED lighted when output is switched
Switching point hysteresis vertically mounted: typically < 3 mm
Medium temperature 0 °C...+90 °C
Ambient temperature 0 °C...+80 °C
Storage temperature 0 °C...+80 °CVibration to be defined
Protection class IP65 (standard)Materials:
sensors aluminium ALMg 3housing ultramidepoxy polyurethane
Connecting cable LVCC, AWG 24, 3 x 0.2 mm2, length min. 0.1 m
Mounting clip-on and lug mounting
Marking laser marking / labelEMC requirements CE logo in accordance with EMC directive
89/336/EWG
Dimensions 59 x 39.5 x 20 mm
Mass approx. 50 g (without cable)
Tube sensor TLS100
04/05158
Dimensions
2
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
potentiometer
sensitivity adjustment22-turn adjustment screw without final stop
red
brown
black
external
free-wheeling diode
-
+
LED+
-
TLS100 (PNP transistor)
load
.472
+
-LED
58.4
43
12
19.6
39.5
10
28
dia. 3.4
tubedia. 9.5-11.9dia. .374-.468
50.4
±0.2
cable
red +
brown load
black –
12
20
potentiometer
.394
.772
1.55
1.10
1.98
±.00
8
.134
2.30
.787
Schematic diagram
Connection diagram HSS
potentiometer
sensitivity adjustment22-turn adjustment screw without final stop
red
brown
black
external
free-wheeling diode
load
TLS100 (NPN transistor)
-
+
LED+
-
Connection diagram LSS
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
Ubatt
signal
GND
reverse polarityprotection
LED
voltage supply
Output
optional
HSS
LSS
micro controller- MIN/MAX, OC- MIN/MAX, RC- switching point
adjustment
sensor interfaceapprox. 400 kHz
capacitivesensor
This is a metric design and millimeter dimensions take precedence ( mm )inch
227 USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510Issue D
7
Load circuitVoltage rating UB DC 24 V (18...36 V)Current rating IN 0.5 A; 1 A; 2 A; 4 A (other ratings to
special order)Closed-circuit current IS typically 0.3 mAMin. load current
Standard version: Iload >1 mAwire break indication in OFF condition
Option: wire break indication in OFF and ON conditionwire break ind. in OFF cond. Rload typ. 500 kΩwire break ind. in ON cond. Iload <typ. 130 mA (0.5/1A unit)
Iload <typ. 500 mA (2/4 A unit)Voltage drop UDSmax 0.15 V; 0.3 V; 0.1 V; 0.2 VSwitch-on/switch-off time ton/toff typ. 300 µs/700 µs with resistive load
Overload disconnection approx. 1.4 x IN after approx. 100 msShort-circuit current max. 25 A (with 0.5 A and 1 A current(self-limiting) ratings)
max. 75 A (with 2 A and 4 A currentratings)
Short-circuit disconnection <250 µs
Control circuitVoltage rating DC 24 VVoltage controlled input UE DC 0 V < low level < 5 V
DC 8.5 V < high level < 36 VInput current IE 1...10 mA (8.5...36 V)Max. switching frequency fmax 500 HzReset time after short-circuit/overload disconnection 1 ms
Fault indication output(opto coupler)Voltage rating range DC 5...36 VMax. load current 100 mA (∆U < 2 V), with reverse polarity
protectionError indication output F+ / F- conductive
- wire break in load circuit- after short-circuit/overload
disconnection
General dataTemperature range 0 °C ... +60 °CInsulation voltage 2.5 kV r ms(IEC 664/VDE 0110)Mass 28 g
Solid State Remote Power Controller E-1048-60.
E-1048-600
Technical data (Tambient = 25 °C; at UN) Typical applications
Automation- interface module providing inexpensive power amplification
at PLC outputs- optimum protection of individual loads by monitoring the load
circuitProtection and control of
- motors- solenoids- lamps
Features
Ordering information
The E-T-A Solid State Remote Power Controller (SSRPC) E-1048-60. isan opto decoupled transistorised switching device providing bothprotection and signalisation.It may be used wherever safe switching and protection of resistive,inductive or lamp loads in DC voltage systems is required.
Description
Optimum load protection. Available in current ratings of 0.5 A; 1 A;2 A; 4 A. No derating required over entire temperature range!
Fast short-circuit limitation and disconnection Time/current dependent overload disconnection (simulating
thermal-magnetic CBE trip curve) Remote control Fault indication: LED and signal output for overload/short-circuit
signalization, and wire break indication in the OFF condition(version -600) and in the OFF and ON condition (version -602)
Physically isolated fault indication. Compact plug-in type
Type No. E-1048 Solid State Remote Power Controller
Version600 wire break indication in OFF condition
(standard)602 with permanent wire break monitoring
Voltage ratingDC 24 V DC 24 V (standard)
Current ratings0.5 A1.0 A2.0 A4.0 A
E-1048 - 600 DC24 V 1.0 A ordering example
Where remote control, wire break and LED indication is not required,please contact us for a thermal-magnetic circuit breaker (e.g. types2210, 3600, 3900).
228 USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510 Issue D
7
Fault indication output(opto coupler)
LEDgreen red
non-conductive, no duty
conductive, normal duty
overload or short circuit at the output(and with option wire break indication inON condition)
wire break, in the OFF position
Status indication
Solid State Remote Power Controller E 1048-60.
At the appropriate input level (>8.5 V), the opto decoupled input in theSSRPC will switch on a power transistor to connect the load to the pluspole of the load circuit supply (UB).The transistor will switch off when
- the control voltage (UE) is removed- there is a short-circuit/overload in the load circuit.
Status indication is provided by two LEDs (red and green).Thermal-magnetic overload protection occurs at approx. 1.4 times ratedcurrent. See time/current characteristic curves.The SSRPC is fitted with blade terminals DIN 46244-A6.3-0.8 and issuitable for plug-in mounting with various E-T-A sockets (see Accessories).
Control circuitON condition:If a voltage higher than 8.5 V is applied to the input terminals (-IN, +IN),the control current (from the PLC) will flow through the opto coupler.Theoutput transistor will be conductive.OFF condition:A control voltage lower than 5 V will switch the output transistor off.
Load circuitThe load circuit switches depending on the control signal (“0” or “1”). Itis electronically monitored for faults. In the event of a short-circuit thecircuit is disconnected after max. 250 µs whilst upon inadmissibleoverload it is disconnected according to the time/current curves shown.
Fault indication outputThe fault indication circuit (F+, F-) is opto decoupled from the load andcontrol circuit.In the OFF condition, this circuit will provide wire break indication, withthe transistor output being open.In the ON condition, the circuit will provide short-circuit and overloadmonitoring and indication.
Technical description
Dimensions
Typical time/current characteristics
Connection diagram
0.5 A and 1 A
Status indication
2 A and 4 A
7
3
2
5control andmonitoringelectronics
F +
F -
control circuit
red
green
load
Q
-UB
4
6
1+UB
E-1048-600
IN+
IN-
fault output
10 20
1000
100
10
1
0.1
30
Trip
tim
e in
ms
I (A)
current limitation
20 40
1000
100
10
1
0.1
60
Trip
tim
e in
ms
I (A)80
IN
IN
current limitation
50
1 4 6 3 7 5 2
56
66
11.5
LED red LED green
2.21
2.60
.453
1.97
229 USA (847) 827-7600 - www.e-t-a.com - CANADA (905) 764-9510Issue D
7
Solid State Remote Power Controller E 1048-60.
Accessories for E 1048-60.
Single mounting sockets with adapter 17-P10-Si 17-P10-Si-20025 (retaining clip Y 300 581 11 available on request)
Bus bar for type 17 socket (for max. 100 A continuous load) X 211 157 01 with terminal X 211 157 02 without terminal
Single mounting sockets 17-P70-Si, same as 17-P10-Si, but with blade terminals to DIN 46 244-C-Ms (2x A 2.8 - 0.8)
Insulated sleeving for bus bar Y 303 824 01
Connector bus links -P10 X 210 588 01/1.5 mm2 brown X 210 588 02/2.5 mm2 black X 210 588 03/2.5 mm2 red X 210 588 04/2.5 mm2 blue
2 mounting clips Installation drawing with Y 300 504 02 mounting clips Y 300 504 02
2-way 6-way mounting socket mounting socket 63-P10-Si (retaining clip Y300 581 03 23-P10-Si available on request)
depth10 mm(.394 in.)
adapter X20040901
symmetrical railEN 50022-35x7.5
polarized blade terminalDIN 46244-A6.3-0.8 (QC .250)
polarization recessG-profileEN 50035-G32
slot fitting labels from Phoenix ZB,RBS, DST Weidmüller dekafix, BS,PES Wieland Type 9003
8.5
25.8
6.5 80
33.3
10
51.4
12.5
41.3
45.8
retaining clip10
6.3
-P10
1
11
23
2(k)
12
24
2(i)
1
11
23
2(k)
12
24
2(i)
1.801.63
.335
.256
1.02
3.15
1.31
.055
.197
.492
.394
.394
.248
2
cylinder head screwM4x4 ISO1207nickel plated
washerA 4.3 DIN 125nickel plated
femaleconnector
Phoenix terminal AKG 35(max.cross section 35 mm2)
M4
10
12.87
154.8pressure-relief joint(1.1 mm (.043 in.)thick constriction)
Cu rail, tin-plated
.394
.079
.504.276
6.09
9
5.4 125
17 .669
.213
.354
4.92
6 x
6.8
= 40
.8
6 x
.268
= 1
.61
retainingclip
22.2
21
10
2
30
6
3.5
6.8
7.4
4.4
64 50 57.4
25
12.5
4.4
7.4
12.5 6.25
64
50
75
12.5
polarized blade terminalsDIN 46244-A6.3-0.8 (QC .250)
polarizedrecess
.173
.291
2.52
1.97
2.26
.492
.984
.291
.173
.394
.827
.874
.079
.236
1.18
2.52
.492
1.97
2.95
50 1.97
2.26
57.4
.268
.138
.492 .246
~70
100 quick-connect tabs 6.3 (.250)DIN 46247 tinned brass,insulated
~2.
761.
9
1
0.5
27.
5
12.5
7.3
8 M4
8.5
60.4
50
16.5 20
2
.075
.039 .295
.079.020
.079
.335
.287
.315
.492
.650 .787
2.38
1.97
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
This is a metric design and millimeter dimensions take precedence ( )mminch
Voltage Monitor E-1079-... for DC
04/05 235
5
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Technical data
Features
Ordering information
E-1079-....
The E-T-A Voltage Monitor E-1079 is designed to monitor DC voltages.The MAX and/or MIN limit value can be directly set by means of thedigital switches provided on the front of the housing. Voltage fallingbelow, or rising above, the preset limit causes the integral relay (change-over contact) to de-energise.The switching delay to compensate for short duration voltage fluctuations may be set beween 0.2 and 30 s by means of thepotentiometer. The monitors operate on the closed-circuit principle, i.e.voltage failure has the same effect as an incorrect voltage level.LEDs provide indication of relay status, operating voltage and adjustment errors (LEDs extinguish when there is a fault).
Voltage ratings AC 115 V 50/60 Hz ( 90...135 V)AC 230 V 50/60 Hz (200...244V)
Power consumption 2 VA
Measuring ranges DC 199 mVRi = 20 kΩDC 1.99 V Ri = 100 kΩDC 19.9 V Ri = 100 kΩ
Accuracy 1% ± 2 digits
Hysteresis 1 digit
Min/Max difference 5 digits (MIN/MAX version only)
Response delay may be set between 0.2 and 30 s
Temperature range 0 ... +50 °C (without condensation)
Relay output AC 250 V/5 A change-over contactDC 30 V/5 A
Degree of protection IP 50 housingIP 20 terminals
Connection 2 x 2.5 mm2 (AWG 14) screw terminals
Mounting 35 mm rail to DIN EN 50022
Dimensions 45 x 74 x 125 mm (W x H x D)
Other measuring ranges and screw-less connectors to Wago licenceare available to special order.
Type No.E-1079 Voltage Monitor
Function31 MAX limit value41 MIN limit value51 MIN/MAX limit value
Voltage rating (supply)AC 115 V ( 90...135 V)AC 230 V (200...244 V)
Measuring rangeDC 199 mVDC 1.99 VDC 19.9 V
E-1079 - 31 - AC 230 V - DC 1.99 V ordering example
Digital limit value preselection Permanent limit value indication Adjustable response delay
Typical applications
Monitoring of limit values for standard signals (e.g. 0...10 V) Monitoring of operating voltages
Voltage Monitor E-1079-... for DC
5
04/05236 Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Version Switches Outputs (terminals) Signalisation
limit value I limit value II MAX relay MIN relay LED-I LED-II
E-1079-31 MAX N/A 8 / 9 / 10 N/A extinguishes when MAX ---Max Voltage Monitor limit is exceeded
E-1079-41 MIN N/A N/A 5 / 6 / 7 extinguishes when voltage ---MIN Voltage Monitor falls below MIN limit
E-1079-51 MAX MIN 8 / 9 / 10 5 / 6 / 7 extinguishes when MAX extinguishes when voltageMIN-MAX Voltage Monitor limit is exceeded falls below MIN limit
Dimensions Connection diagram
Typical time / voltage characteristics
45
1 2 3 4 5
6 7 8 9 10
I
II
E-1079
limit value I
limit value II
monitoringcircuit
AC 230 V
MAX relay
MIN relay
LED-I
LED-II
LED-UB
LED-Err
tV-I
tV-II
tv (adjustable) tv (adjustable)
trelayde-energized
relay MAXenergized
relay MINenergized
relay status
limit valueMIN
limit valueMAX
tON
U B
t
indicated value
supply voltage
tmax ON
tmin ONtmax OFF
tmin OFF tmin ON tmin OFF
tOFF
45 124
7470
1.77 4.88
2.76
2.91
Function of digit switches and relay terminal assignment
tv-I response delay of limit value I,may be set between 0.2 and 30 s.
LED-UB lights when operating voltage is applied
only with version E-1079-51:
tv-II response delay of limit value II,may be set between 0.2 and 30 s.
LED-Err extinguishes upon adjustment errorlimit value I < (limit value II + 5 digits)
Contacts shown with the supply disconnected.This is a metric design and millimeter dimensions take precedence ( mm )inch
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
Electronic Voltage Monitor E-1079-600/-601-...
04/05 237
5
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Description
Ordering information
Features
E-1079-600-...
The electronic E-T-A Voltage Monitor E-1079-60. is designed tomonitor DC or AC voltages against falling below, or rising above,preset tolerance limits. Two LEDs indicate relay status or overlimits; anopto coupler output provides a physically isolated signal.The device is available either with a (non-conducting) N/O or a(conducting) N/C contact. It is powered by the measuring signal sothat there is no need for an additional power supply.
Technical data
Voltage under and over limit monitoring (tolerance window) For DC and AC voltages between 5 V and 230 V DC and AC voltage output N/O or N/C contact (MOSFET) Status indication by red and green LEDs No need for separate power supply Reverse polarity protection Compact design (plug-in housing) 12 mm wide housing
Type No.E-1079 Electronic Voltage Monitor
Output600 signal output as N/O contact601 signal output as N/C contact
Voltage ratingDC 12 VDC 24 VDC 48 VDC 110 VDC 220 VAC 115 VAC 230 V
E-1079 -600 - DC 24 V ordering example
Input voltage UE
Voltage rating UN Tolerance Tolerance range Umin...Umax
DC 12 V ± 25% ( 9 ... 15 V)DC 24 V ± 25% (18 ... 30 V)DC 48 V ± 25% (36 ... 60 V)DC 110 V +10%/-15% (93.5 ... 121 V)DC 220 V +10%/-15% (187 ... 242 V)AC 115 V +10%/-15% (97.8 ... 126.5V)AC 230 V +10%/-15% (195.5 ... 253 V)
Load current 3 mA DC and ACDielectric strength 260 V DC and ACReverse polarity protected
Output UA/IAMOSFET outputMax. load current 80 mA DC and ACMax. load voltage 250 V DC and ACVoltage drop < 2.0 V with 80 mA load
< 0.8 V with 10 mA loadFree-wheeling diode for non-resistive loads in-builtPolarization optionalResponse time 200 mA
Signalling (> 5 V signal voltage)green LED voltage within set tolerance limitsred LED voltage outside set tolerance limits
AccuracyUndervoltage Umin -10%UN ... Umin
Overvoltage Umax ... Umax +10%UN
Environmental conditionsTemperature range 0 ... 60 °C (without condensation)Degree of protection to DIN 40050/IEC 529 IP 20Dielectric strength (IEC 664) 4 kVrms
EMC to EN50081-1 and prEN50082-2
Housing plug-in ultramid housing
Terminals 6.3 mm blade terminals to DIN 46244to plug into E-T-A socket 17-P10-Si
Mounting attitude optional, no air gap between devices required
Mass 28 g
Electronic Voltage Monitor E-1079-600/-601-...
5
04/05238 Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Function Functional diagram
output is active
output is inactive
output is active
output is inactive
LED red
LED green
LED red
LED green
LED red
LED green
LED red
LED green
LED red
LED green
LED red
LED green
LED red
LED green
0 V 5 V -10% +10%Umin UmaxUN
LED red
LED green
UE
E-1079-600
0 V 5 V -10% +10%Umin UmaxUN UE
E-1079-601
The operating voltage applied at the input terminals is monitored forupper and lower limits. When the input signal is within tolerance limits, the green LED will indicate and the MOSFET of the signal output hasthe following operating status:
- N/O contact (-600): MOSFET is active- N/C contact (-601): MOSFET is inactive
From approx. 5 V to the lower tolerance limit the red LED will indicate.It also indicates when the upper tolerance limit has been exceeded.The output will change its operating status.
Connection diagram
E-1079-600
(~UE)
comparator
input voltage
2
3
6
+UE
1
green
red
(~UE)
UA
UA
output(unpolarized)
input voltage
-UE
E-1079-601
(~UE)
comparator
input voltage
2
7
3
+UE
1
green
red
(~UE)
UA
UA
output(unpolarized)
input voltage
-UE
Dimensions
50
5665
12
LED green LED red
2.21
2.56
.472
1.97
50
1 4 6 3 7 5 2
5665
12
LED green LED red
1 4 6 3 7 5 2
E-1079-600
E-1079-601
2.21
2.56
.472
1.97
This is a metric design and millimeter dimensions take precedence ( mm )inch
Electronic Voltage Monitor E-1079-600/-601-...
04/05 239
5
Phone: Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com
Accessories for E-1079-600/601
9
5.4 125
17 .669
.213
.354
4.92
2
cylinder head screwM4x4 ISO1207nickel plated
washerA 4.3 DIN 125nickel plated
femaleconnector
Phoenix terminal AKG 35max.cross section 35 mm2 (AWG 2)
M4
10
12.87
154.8pressure-relief joint(1.1 mm (.043 in.)thick constriction)
Cu rail, tin-plated
.394
.079
.504.276
6.09
blade terminal DIN 46244 part 2C profile (2xA2.8-0.8) (QC 2x.110)
depth10 mm(.394 in.)
adapter X20040901
symmetrical railEN 50022-35x7.5
polarization recessG-profileEN 50035-G32
8.5
25.8
6.5 80
33.3
10
51.4
12.5
41.3
45.8
retaining clip
1
11
23
2(k)
12
24
2(i)
1
11
23
2(k)
12
24
2(i)1.
801.63
.335
.256
1.02
3.15
1.31
.055
.197
.492
.394
polarized blade terminalDIN 46244-A6.3-0.8 (QC .250)
slot for fitting labels fromPhoenix ZB, ZBFWeidmüller dekafix
10
6.3
-P10
10
2.8
-P70
.394
.248
.394
.110
Single mounting sockets (with adapter)(up to 16 A max. load)17-P10-Si 17-P10-Si-2002517-P70-Si 17-P70-Si-20025(retaining clip Y 300 581 11 available on request)
Bus bar (10-way) (supplied as a complete package)for type 17 socket(for max. 100 A continuous load),more positions available on requestX 211 157 01 with terminalX 211 157 02 without terminal
Insulating sleeving for bus bar (10-way)Y 303 824 01
Connector bus links -P10X 210 588 01/ 1.5 mm2, (AWG 16), brown (up to 13 A max. load)X 210 588 02/ 2.5 mm2, (AWG 14), black (up to 20 A max. load)X 210 588 03/ 2.5 mm2, (AWG 14), red (up to 20 A max. load)X 210 588 04/ 2.5 mm2, (AWG 14), blue (up to 20 A max. load)
2-way mounting socket 6-way mounting socket23-P10-Si 63-P10-Si(retaining clip Y 300 581 03 available on request)
2 mounting clips Installation drawing withY 300 504 02 mounting clips Y 300 504 02
6 x
6.8
= 40
.8
6 x
.268
= 1
.61
retainingclip
22.2
21
10
2
30
6
3.5
6.8
7.4
4.4
64 50 57.4
25
12.5
4.4
7.4
12.5 6.25
64
50
75
12.5
polarized blade terminalsDIN 46244-A6.3-0.8 (QC .250)
polarizedrecess
.173
.291
2.52
1.97
2.26
.492
.984
.291
.173
.394
.827
.874
.079
.236
1.18
2.52
.492
1.97
2.95
50 1.97
2.26
57.4
.268
.138
.492 .246
~70
100 quick-connect tabs 6.3 (.250)DIN 46247 tinned brass,insulated
~2.
76
1.9
1
0.5
27.
5
12.5
7.3
8 M4
8.5
60.4
50
16.5 20
2
.075
.039 .295
.079.020
.079
.335
.287
.315
.492
.650 .787
2.38
1.97
All dimensions without tolerances are for reference only. In the interest of improved design,performance and cost effectiveness the right to make changes in these specifications withoutnotice is reserved. Product markings may not be exactly as the ordering codes. Errors andomissions excepted.
This is a metric design and millimeter dimensions take precedence ( mm )inch
THERMAL MAGNETIC CIRCUIT BREAKER QUICK LINKS
201/-WA
VIEW PDF FILE
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a narrow profile housing, recessed terminals, standard EN rail mounting, and precision CBE performance.Approved to CBE standard EN 60934 (IEC 60934)
2210-S2
VIEW PDF FILE
One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Designed for panel or plug-in mounting. Available with auxiliary contacts (1 x N/O, 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. A choice of characteristic curves further extends the range of applications possibilities for these CBEs. Approved to CBE standard EN 60934 (IEC 60934). Suitable for use in distribution rails.
2210-S291
VIEW PDF FILE
Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact arrangement to provide high voltage DC capability and high switching performance. Designed for plug-in mounting in distribution rails X 2210-S0606J, X 2210-K, or terminal blocks 23-P10- Si-202005 and 63-P10-Si-202005. Approved to CBE standard EN 60934 (IEC 60934).
2215-L.../G...
VIEW PDF FILE
Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models.Suitable for use in distribution rails – see section 7.Complies with CBE standard EN 60934 (IEC 60934).
2215-F1
VIEW PDF FILE
Miniaturized two pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Fitted with panel mounting flange and push-on termination, also suitable for mounting on Euro Cards. Available with auxiliary contacts and a choice of fast, medium or long delay characteristics.Complies with CBE standard EN 60934 (IEC 60934).
3120-...-M1-...
VIEW PDF FILE
Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 60934). The addition of a magnetic tripping module to the type 3120 range described in catalogue section 1 extends the choices available to include single pole with thermal-magnetic protection; double pole switching with thermalmagnetic protection on one pole, thermal protection on the other;double pole switching with thermal-magnetic protection on one pole only. All are offered with rocker switch or push button control - twobuttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional. Approved to CBE standard EN 60934 (IEC 60934).
3120--F7..-M1-..
VIEW PDF FILE
Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 60934). The addition of a magnetic tripping module to the type 3120 range described in catalogue section 1 extends the choices available to include single pole with thermal-magnetic protection; double pole switching with thermal-magnetic protection on one pole, thermal protection on the other; double pole switching with thermal-magnetic protection on one pole only. All are offered with rocker switch actuation. Illumination is optional. Approved to CBE standard EN 60934 (IEC 60934).
3200
VIEW PDF FILE
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, press-to-reset, snap action mechanism and additional manual release (M-type TM CBE to EN 60934). Designed for plug-in mounting withE-T-A sockets 10 and 16. Approved to CBE standard EN 60934 (IEC 60934).
3300/3400
VIEW PDF FILE
Single pole thermal-magnetic circuit breakers with tease-free, trip-free, press-to-reset, snap action mechanism (R-type TM CBE to EN 60934; M-type with manual release -H). Available with fast acting and standard magnetic tripping characteristics - types 3300 and 3400 - both with threadneck panel mounting. Options include auxiliary contacts, a separate shunt tap terminal (-A3), and pull-to-trip manual release (-H).Approved to CBE standard EN 60934 (IEC 60934).
3500/4000
VIEW PDF FILE
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring a flange for panel mounting, and optional auxiliary contacts and unprotected shunt tap terminal. Type 4000 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated.Approved to CBE standard EN 60934 (IEC 60934).
3600/3900
VIEW PDF FILE
Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Designed for plug-in mounting with E-T-A sockets 17-P10-Si, 23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring an unprotected shunt tap terminal and optional auxiliary contacts. Type 3900 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated. Approved to CBE standard EN 60934 (IEC 60934).
[Main Products Page] [Thermal] [Thermal Magnetic] [Magnetic] [High Performance]
[Door Locking, Time Delay & Motor Controls] [Power Distribution] [Control Products] [SSRPCs]