Upload
vungoc
View
213
Download
0
Embed Size (px)
Citation preview
Ref. 9.609 - 2014-04-22. www.axel-larsson.se
MAGNETVENTIL G 1/8" - 1/4"Lucifer 341-347 P För pneumatisk styrning
9.609 - 1
5/2 - Monostabil Anslut-
ning(G")
Genom-lopp
(mm)
Kapacitet (l/min)
Tryckfall ∆ p (bar)
Media-temperatur
Tätning Ventil Spolhus / Anslutning
Spole Effekt(W)
Spol-grupp
Fig
Gas Qn
Min Max Min°C
Max°C
AC DC
AC DC
1/8 4 600
2 10 10 -25 +80 Nitril 341P01 DIN 488980 2 2,5 1.1 A
2 10 10 -25 +80 Nitril 341P21 DIN 481865 8 9 2.1 B
2 10 10 -40 +65 PUR 341P2108 DIN 481865 8 9 2.1 B
2 - 10 -25 +80 Nitril/PUR 341P2197 DIN 482740 - 1,6 6.0 / 8.0 B
2 - 10 -25 +55 Nitril 341P2190 DIN 483580.01 - 0,5 7.0 C
1/4 8 1400
2 10 10 -25 +80 Nitril 341P02 DIN 488980 2 2,5 1.1 D
2 10 10 -25 +80 Nitril 341P22 DIN 481865 8 9 2.1 E
2 - 10 -25 +80 Nitril/PUR 341P2297 DIN 482740 - 1,6 6.0 / 8.0 E
2 - 10 -25 +55 Nitril 341P2290 DIN 483580.01 - 0,5 7.0 F
5/2 - Impulsstyrd Anslut-
ning(G")
Genom-lopp
(mm)
Kapacitet (l/min)
Tryckfall ∆ p (bar)
Media-temperatur
Tätning Ventil Spolhus / Anslutning
Spole Effekt(W)
Spol-grupp
Fig
Gas Qn
Min Max Min°C
Max°C
AC DC
AC DC
1/8 4 6002 10 - -25 +80 Nitril
345P214269 484990 11 - 4.0 G
2 - 10 -25 +80 Nitril 4269 485400 - 13 4.0 G
5/2 - Bistabil Anslut-
ning(G")
Genom-lopp
(mm)
Kapacitet (l/min)
Tryckfall ∆ p (bar)
Media-temperatur
Tätning Ventil Spolhus / Anslutning
Spole Effekt(W)
Spol-grupp
Fig
Gas Qn
Min Max Min°C
Max°C
AC DC
AC DC
1/8 4 400
2 10 10 -25 +80 Nitril 347P01 DIN 488980 2 2,5 1.1 H
2 10 10 -25 +80 Nitril 347P21 DIN 481865 8 9 2.1 I
2 - 10 -25 +80 Nitril 347P2190 DIN 483580.01 - 0,5 7.0 J
1/4 8 14002 10 10 -25 +80 Nitril 347P02 DIN 488980 2 2,5 1.1 K
2 10 10 -25 +80 Nitril 347P22 DIN 481865 8 9 2.1 L
Applikationer: Pneumatisk styrning.
Modulsystem: Välj ventil och önskad spole inom samma spolgrupp, se blad för resp. spole. Tabell nedan avser standardspolar.
Funktion: 5/2 pilotstyrd
Ventilhus: Aluminium
Omgivningstemp: Se uppgift för vald spole, separat datablad.
Skyddsklass: IP 10 - IP 67 beroende på val av spole.
Tillval: Ex-utförande för spolgrupp 1.1, t.ex. 482606 Ex mb IIC T4 Ex-utförande för spolgrupp 2 .1, t.ex. 495905 Ex db mb IIC T4 Ex-utförande för spolgrupp 8.0, t.ex. 495910 Ex ia IIC T4. DIN med LED / ingjuten kabel. Hastighetsreglering med strypljuddämpning.
Beställningsex: 341P01 - 488980 - 230/50 (ventil - spole - spänning)
Monostabil
Bistabil
Monostabil (intern pilotavluftning)
Bistabil (intern pilotavluftning)
Ref. 9.609 - 2014-04-22. www.axel-larsson.se
MAGNETVENTIL G 1/8" - 1/4"Lucifer 341-347 P För pneumatisk styrning
9.609 - 2
317 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7302
Drawing 7296
Drawing 8027
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 4 600 10 -40 -40
To 1/8'' 4 600 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
317 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7302
Drawing 7296
Drawing 8027
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 4 600 10 -40 -40
To 1/8'' 4 600 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
319 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7351
Drawing 8218
Drawing 8219
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 7 600 10 -25 -25
To 1/4'' 15 1400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
318 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
ANODIZED ALUMINIUM
NORMALLY CLOSED PIPE MOUNTING
Port size
Orifi ceØ
Flowfactor
OperatingPressure
Differential
Fluid Temp.
Seat Seal
Parker LUCIFER®
ValvesATEXZone
ProtectionMode
Power Coil Group
Dwg.No.
1 Valve Ref.
Housing Ref.
Coil Ref.
Min Max (MOPD) Min Max
BSP mmQn
l/min barACbar
DCbar °C °C
ACW
DCW
1/8''
15 600 2 - 10 -10 55 NBR 341P2190 2 2995 483580.01 0-20 Ex ia IIC T6 - 0.5 to 3 7.0/8.0 7351
15 600 2 - 10 -10 75 NBR 341P2190 2 - 488660.01 0-20 Ex ia IIC T6 - 0.3 to 3 7.0/8.0 7351
15 600 2 - 10 -10 75 NBR 341P2190 2 - 495910 0-20 Ex ia IIC T4 to T6 - 0.3 to 3 7.0/8.0 7351
1/4''
7 1250 2.5 10 10 -10 50 NBR 341P03 2 - 496131 - - 3 3 1.2 8218
7 1250 2.5 10 10 -10 50 NBR 341P03 2 - 496482 - - 3 3 1.2 8218
7 1250 2.5 10 10 -10 50 NBR 341P03 2 - 496637 22 Ex tc IIIC T95°C 3 3 1.2 8218
7 1250 2.5 10 10 -10 50 NBR 341P33 2 2995 481865 - - 8 9 2.1 8219
7 1250 2.5 10 10 -10 50 NBR 341P33 2 2995 495870 2-22 Ex nAc nCc IIC T3/T4 8 9 2.1 8219
7 1250 2.5 10 10 -10 50 NBR 341P33 2 - 495905 1-21 Ex db mb IIC T4 8 8 2.1 8219
8 1400 2 10 10 -25 80 NBR 341P02 2 - 482606 1-21 Ex mb IIC T4/T5 2 2.5 1.1 7314
8 1400 2 10 10 -25 80 NBR 341P02 2 8993 488980 - - 2 2.5 1.1 7314
Notes: 1. Pilot seat in FKM 2. With manual override
Drawing 7314
3 & 5 WAY PNEUMATIC DISTRIBUTORS
PILOT OPERATED
3 & 5 WAY PNEUMATIC VALVES FOR ACTUATOR CONTROL (PIPE MOUNTING) 5/2 5/2
321 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7319
Drawing 7352
Drawing 8030
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/4'' 8 1400 10 -25 -25
To 1/4'' 8 1400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
321 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7319
Drawing 7352
Drawing 8030
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/4'' 8 1400 10 -25 -25
To 1/4'' 8 1400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS Fig A Fig B
Fig C Fig D
Fig E Fig F
Ref. 9.609 - 2014-04-22. www.axel-larsson.se
MAGNETVENTIL G 1/8" - 1/4"Lucifer 341-347 P För pneumatisk styrning
9.609 - 3
329 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 8224
Drawing 8225
Drawing 8123
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 4 600 10 -25 -25
To 1/2'' 12 3000 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
325 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7306
Drawing 7298
Drawing 7353
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 4 400 10 -25 -25
To 1/8'' 4 400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
325 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7306
Drawing 7298
Drawing 7353
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 4 400 10 -25 -25
To 1/8'' 4 400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
325 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 7306
Drawing 7298
Drawing 7353
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/8'' 4 400 10 -25 -25
To 1/8'' 4 400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
327 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
Drawing 8222
Drawing 8223
Drawing 7316
For this page
Port size
Orifi ce(mm)
Qn (l/min)
MOPD(bar)
Fluid Temp(°C)
Amb Temp(°C)
From 1/4'' 7 1250 10 -25 -25
To 1/4'' 8 1400 10 80 50
3 & 5 WAY PNEUMATIC DISTRIBUTORS
326 Parker Hannifi n CorporationFluid Control Division Europe
General Catalogue FCDE/0110/UK/V2.0
ANODIZED ALUMINIUM
DUAL SOLENOIDS PIPE MOUNTING
Port size
Orifi ceØ
Flowfactor
OperatingPressure
Differential
Fluid Temp.
Seat Seal
Parker LUCIFER®
ValvesATEXZone
ProtectionMode
Power Coil Group
Dwg.No.
1 Valve Ref.
Housing Ref.
Coil Ref.
Min Max (MOPD) Min Max
BSP mmQn
l/min barACbar
DCbar °C °C
ACW
DCW
1/4''
7 1250 2.5 10 10 -10 50 NBR 347P03 2 - 496131 - - 3 3 1.2 8222
7 1250 2.5 10 10 -10 50 NBR 347P03 2 - 496482 - - 3 3 1.2 8222
7 1250 2.5 10 10 -10 50 NBR 347P03 2 - 496637 22 Ex tc IIIC T95°C 3 3 1.2 8222
7 1250 2.5 10 10 -10 50 NBR 347P33 12 2995 481865 - - 8 9 2.1 8223
7 1250 2.5 10 10 -10 50 NBR 347P33 12 2995 495870 2-22 Ex nAc nCc IIC T3/T4 8 9 2.1 8223
7 1250 2.5 10 10 -10 50 NBR 347P33 12 - 495905 1-21 Ex db mb IIC T4 8 8 2.1 8223
8 1400 2 10 10 -25 80 NBR 347P02 2 - 482606 1-21 Ex mb IIC T4/T5 2 2.5 1.1 7316
8 1400 2 10 10 -25 80 NBR 347P02 2 8993 488980 - - 2 2.5 1.1 7316
8 1400 2 10 10 -25 80 NBR 347P22 12 2995 481865 - - 8 9 2.1 7321
8 1400 2 10 10 -25 80 NBR 347P22 12 4270 481000 - - 8 8 2.1 7321
Notes: 1. Pilot seat in FKM 2. With manual override
Drawing 7321
3 & 5 WAY PNEUMATIC DISTRIBUTORS
PILOT OPERATED
3 & 5 WAY PNEUMATIC VALVES FOR ACTUATOR CONTROL (PIPE MOUNTING) 5/2 5/2
Fig G Fig H
Fig I Fig J
Fig K Fig L
STOCKHOLM GÖTEBORG MOTALA KARLSTAD FALUN SKELLEFTEÅ Förb
ehål
l för
tekn
iska
ändr
inga
r uta
n av
iserin
g