    Current Capacities (*)

    20C in c.c. 50 Hz 2x 3x 4x 5x 7x 12x 19x 24x 37x

    ohm/km ohm/km Amp Amp Amp Amp Amp Amp Amp Amp Amp

    1.5 12.1 0.103 19 16 16 12 10.4 8.5 7.2 6.4 5.6

    2.5 7.41 0.096 26 22 22 16.5 14.3 11.7 9.9 8.8 7.7

    4 4.61 0.096 35 30 30 22.5 19.5 15.9 13.5 12 10.5

    (*) In free air at 40C, according to IEC 364-5-523 and VDE 0298, Part 3.

    Nx - Number of conductors.

    Electric Characteristics

    Control 71

    These specifications are intended for reference purposes only and can be modified without prior notice.

    Specifications

    Rated voltage: 600/1000 Volt a.c., 1200 Volt a.c. and 1800 Volt d.c. maximum.

    Service temperature: 70C maximum.

    Standards: Low voltage electrical installations, AEA Regulations, IEC 60364, IEC 79-14, suitable for 0-1-2 zone classified

    areas. EMC electromagnetic compatibility.

    Construction: IRAM 2178, IRAM 2268, IEC 60502-1, HN 33-S-34.

    Fire: Fire retardant, IRAM 2289 cat. C, IEC 60332-3 cat. C.

    EMC: Transfer impedance lower than 2 ohm/km up to 1MHz (according to IRAM 2268 and HN 33-S-34).

    Corrugated copper shielded multiconductor cable - 1.1KV - 70C.

    Description

    Conductor: Annealed copper, Class 2.

    Insulation: PVC.

    Identification: White with numbers and letters printed in black.

    Shielding: longitudinal overlapped corrugated copper tape.

    Sheath: Fire retardant violet PVC.

    Installation

    Assembly: Minimum radius 12 x External Diameter. Maximum pulling tension on copper conductors: 5 daN/mm2.

    Applications

    Suitable for high voltage substations and for variable frequency motor driving.

    GM CORCOM

    See technical note on page 132.

    NominalCross-section

    mm2

    Electric

    Resistance

    Inductive

    Reactance

  • 7/29/2019 Marlew Catlogo 2005 back_(4_ (6)

    2/2

    72 Control

    These specifications are intended for reference purposes only and can be modified without prior notice.

    GM CORCOMCorrugated copper shielded multiconductor cable - 1.1KV - 70C.

    2x2,5 GM 0225 15.5 357

    3x2,5 GM 0325 15.8 382

    4x2,5 GM 0425 16.7 426

    5x2,5 GM 0525 17.7 470

    7x2,5 GM 0725 18.8 554

    12x2,5 GM 1225 23.0 782

    19x2,5GM 1925

    26.1 106124x2,5 GM 2425 29.7 1289

    30x2,5 GM 3025 31.2 1530

    37x2,5 GM 3725 33.3 1789

    Conductors

    Per cross-section Code

    N x mm2 mm kg/km

    2x1,5 GM 0215 15.5 343

    3x1,5 GM 0315 15.5 352

    4x1,5 GM 0415 15.5 359

    5x1,5 GM 0515 16.6 399

    7x1,5 GM 0715 17.6 461

    12x1,5 GM 1215 21.3 618

    19x1,5 GM 1915 24.0 825

    24x1,5 GM 2415 27.2 999

    30x1,5 GM 3015 28.5 1159

    37x1,5 GM 3715 30.5 1349

    2x4 GM 0240 17.0 431

    3x4 GM 0340 17.7 482

    4x4 GM 0440 19.0 550

    5x4 GM 0540 20.2 6187x4 GM 0740 21.7 747

    12x4 GM 1240 27.1 1102

    19x4 GM 1940 30.8 1536

    Diameter Weight

    Dimensions and Weight

    Conductors

    Per cross-section Code

    N x mm2 mm kg/km

    Diameter Weight

    Conductors

    Per cross-section Code

    N x mm2 mm kg/km