Upload
victor-leandro-e
View
224
Download
0
Embed Size (px)
Citation preview
7/29/2019 Marlew Catlogo 2005 back_(4_ (6)
1/2
Current Capacities (*)
20C in c.c. 50 Hz 2x 3x 4x 5x 7x 12x 19x 24x 37x
ohm/km ohm/km Amp Amp Amp Amp Amp Amp Amp Amp Amp
1.5 12.1 0.103 19 16 16 12 10.4 8.5 7.2 6.4 5.6
2.5 7.41 0.096 26 22 22 16.5 14.3 11.7 9.9 8.8 7.7
4 4.61 0.096 35 30 30 22.5 19.5 15.9 13.5 12 10.5
(*) In free air at 40C, according to IEC 364-5-523 and VDE 0298, Part 3.
Nx - Number of conductors.
Electric Characteristics
Control 71
These specifications are intended for reference purposes only and can be modified without prior notice.
Specifications
Rated voltage: 600/1000 Volt a.c., 1200 Volt a.c. and 1800 Volt d.c. maximum.
Service temperature: 70C maximum.
Standards: Low voltage electrical installations, AEA Regulations, IEC 60364, IEC 79-14, suitable for 0-1-2 zone classified
areas. EMC electromagnetic compatibility.
Construction: IRAM 2178, IRAM 2268, IEC 60502-1, HN 33-S-34.
Fire: Fire retardant, IRAM 2289 cat. C, IEC 60332-3 cat. C.
EMC: Transfer impedance lower than 2 ohm/km up to 1MHz (according to IRAM 2268 and HN 33-S-34).
Corrugated copper shielded multiconductor cable - 1.1KV - 70C.
Description
Conductor: Annealed copper, Class 2.
Insulation: PVC.
Identification: White with numbers and letters printed in black.
Shielding: longitudinal overlapped corrugated copper tape.
Sheath: Fire retardant violet PVC.
Installation
Assembly: Minimum radius 12 x External Diameter. Maximum pulling tension on copper conductors: 5 daN/mm2.
Applications
Suitable for high voltage substations and for variable frequency motor driving.
GM CORCOM
See technical note on page 132.
NominalCross-section
mm2
Electric
Resistance
Inductive
Reactance
7/29/2019 Marlew Catlogo 2005 back_(4_ (6)
2/2
72 Control
These specifications are intended for reference purposes only and can be modified without prior notice.
GM CORCOMCorrugated copper shielded multiconductor cable - 1.1KV - 70C.
2x2,5 GM 0225 15.5 357
3x2,5 GM 0325 15.8 382
4x2,5 GM 0425 16.7 426
5x2,5 GM 0525 17.7 470
7x2,5 GM 0725 18.8 554
12x2,5 GM 1225 23.0 782
19x2,5GM 1925
26.1 106124x2,5 GM 2425 29.7 1289
30x2,5 GM 3025 31.2 1530
37x2,5 GM 3725 33.3 1789
Conductors
Per cross-section Code
N x mm2 mm kg/km
2x1,5 GM 0215 15.5 343
3x1,5 GM 0315 15.5 352
4x1,5 GM 0415 15.5 359
5x1,5 GM 0515 16.6 399
7x1,5 GM 0715 17.6 461
12x1,5 GM 1215 21.3 618
19x1,5 GM 1915 24.0 825
24x1,5 GM 2415 27.2 999
30x1,5 GM 3015 28.5 1159
37x1,5 GM 3715 30.5 1349
2x4 GM 0240 17.0 431
3x4 GM 0340 17.7 482
4x4 GM 0440 19.0 550
5x4 GM 0540 20.2 6187x4 GM 0740 21.7 747
12x4 GM 1240 27.1 1102
19x4 GM 1940 30.8 1536
Diameter Weight
Dimensions and Weight
Conductors
Per cross-section Code
N x mm2 mm kg/km
Diameter Weight
Conductors
Per cross-section Code
N x mm2 mm kg/km
Diameter Weight