contents MK 2200L MK 2200 MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A MK 201A MK 202A MK 300A / 300EA MK 330A MK 301A / 302A / 301E DIN 330 DIN 310 / 310E DIN 300 / 300E ZCT 40S / 60S / 80S / 120S / 210S MU 2300 MU 350 MU 250 / 150 MX 210 MX 200A / 180A / 160A MX 100 / 50 RPR 415A RPR 415 PFR 140 / 120 / 80 / 60 PFR 96 / 96P PFR LCD AN 112 / 120 / 128 AL 24 DVM DAM DPM 680 DPM 380 / 380B DM 38 Combined Overcurrent & Earth Fault Relay Overcurrent Relay Earth Fault Relay Earth Leakage Relay Voltage Relay Reverse Power Relay Power Factor Regulator Annunciator Digital Power Meter MPR 500 Motor Protection Relay reference colour tags

MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Embed Size (px)

Citation preview

Page 1: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

contents

MK 2200LMK 2200MK 1000A

MK 233AMK 234AMK 203AMK 204A

MK 231AMK 232AMK 201AMK 202A

MK 300A / 300EAMK 330AMK 301A / 302A / 301EDIN 330DIN 310 / 310EDIN 300 / 300EZCT 40S / 60S / 80S / 120S / 210S

MU 2300MU 350MU 250 / 150MX 210MX 200A / 180A / 160AMX 100 / 50

RPR 415ARPR 415

PFR 140 / 120 / 80 / 60PFR 96 / 96PPFR LCD

AN 112 / 120 / 128AL 24

DVMDAMDPM 680DPM 380 / 380BDM 38

Combined Overcurrent &Earth Fault Relay

Overcurrent Relay

Earth Fault Relay

Earth Leakage Relay

Voltage Relay

Reverse Power Relay

Power Factor Regulator

Annunciator

Digital Power Meter

MPR 500Motor Protection Relay

reference colour tags

Page 2: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Print EditionJune 2015

( 423468-T )

No.1 Jalan TP 7/7, Sime UEP Industrial Park,40400 Shah Alam, Selangor, Malaysia.Website: www.itmikro.com Tel: +60-3-5192-7155 Fax: +60-3-5192-7166

Mikro® reserves the right to make changes without further notice to any products herein to improve reliability, function or design. The figures shown are without obligation.

Page 3: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK2200L

Technical Data

RATINGS

Auxiliary SupplyModel MK2200L-150DRated voltage : 30 ~ 120 V DCOperating voltage : 24 ~ 150 V DC

Model MK2200L-240ADRated voltage : 100 ~ 240 V AC or 140 ~ 340 V DCOperating voltage : 85 ~ 265 V AC or 110 ~ 370 V DCRated frequency : 50 or 60 HzOperating frequency : 45 ~ 65 HzPower consumption : 8 VA max

Current Inputs Rated current, In, Ion : 1 or 5 A by connectionFrequency : 50 or 60 Hz nominalBurden : < 0.025 VA (1 A) : < 0.3 VA (5 A)Thermal withstand : 4 x In continuous : 40 x In for 2s : 100 x In for 1s

Digital Inputs Input type : Optically isolatedRated voltage : 20 ~ 380 V DC : 50 ~ 270 V AC

Output Contacts Trip Contact Relay R1, R2, R3, R4, IRF RelayRated voltage : 250 V AC / DCContinuous carry : 5 AExpected electrical life : 100,000 operations at rated loadExpected mechanical life : 5 x 106 operations

Features

• Multifunction numerical relay

• Three-phase, three stages setting for phase overcurrent

• Two stages setting for earth fault

• IDMT and definite time

• Thermal overload protection

• Two groups of protection settings

• Trip circuit supervision

• Circuit breaker failure protection

• RS232 and RS485 MODBUS-RTU communication

• Fault, alarm and tripping records with timestamp

• Multifunction programmable outputs

• Multifunction digital inputs

• Complies with IEC 60255-26 standard

• ANSI code : 49RMS, 50P, 50G, 51P, 51G, CLP, 50BF, 74TC

Com

bined Overcurrent &

Earth Fault R

elay

RECORDS Fault Record : Up to 50 recordsEvent Record : Up to 250 recordsAlarm Record : Up to 30 records

SETTING RANGES

General Line CT primary : 1 to 10,000 AEarth CT primary : 1 to 10,000 AFrequency : 50 or 60 Hz

Phase Overcurrent I> : 0.1 to 25 x In (Recommended up to

2 x In for IDMT delay)I> Delay type : IDMT or definite timetI> : 0 to 100 sI> IDMT curve : NI, VI, EI, LTI, NI 1.3/10ktI : 0.01 to 1.00I>> : 0.5 to 40 x IntI>> : 0 to 100 sI>>> : 0.5 to 40 x InI>>> Sample : Yes or NotI>>> : 0 to 100 s

Earth Fault Io> : 0.02 to 2 x Ion (Recommended up

to 0.5 x Ion for IDMT delay)Io> Delay type : IDMT or definite timetIo> : 0 to 100 sIo> IDMT curve : NI, VI, EI, LTI, NI 1.3/10ktIo : 0.01 to 1.00Io>> : 0.1 to 10 x IontIo>> : 0 to 100 s

Thermal Overload I > : 0.1 to 3 x InT : 1 to 200 minutesk : 1 to 1.5

Trip : 50 to 200%Alarm : 50 to 200%

MEASUREMENT RANGES Phase Current Secondary:5 A input : 0 to 200 A1 A input : 0 to 40 A

Earth Current Secondary:5 A input : 0 to 50 A1 A input : 0 to 10 A

ENVIRONMENTAL CONDITIONS Temperature : -5˚C to 55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICAL Mounting : Panel mountingDimension (mm) : 142(w) x 165(h) x 198(d)Enclosure protection : IP54 at the panelApproximate weight : 2.9 kg

MK

2200L

Page 4: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Ordering Information

MK2200L - 150D For 50/60 Hz, auxiliary voltage 24 ~ 150 V DCMK2200L - 240AD For 50/60 Hz, auxiliary voltage 85 ~ 265 V AC or 110 ~ 370 V DC

MODEL DESCRIPTION

Case Dimensions

Normal Inverse Very Inverse Extremely Inverse

Long Time InverseTypical Application Diagram 1

Typical Application Diagram 2

Com

bined Overcurrent &

Earth Fault R

elay142 mm

165

mm

Front

Panel Cutout

198 mm34 mm

136

mm

Side

139

±1 m

m

129 ±1 mm

MK

2200L

Page 5: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK2200

Technical Data

INPUTS Measuring input: Rated current In : 1 A or 5 ARated frequency : 50 or 60 HzThermal withstand : 4 x In continuous 25 x In for less than 10 sec 100 x In for less than 1 secBurden : < 0.3VA at In

Rated auxiliary voltage:Model MK2200-150D : 24~150 V DCModel MK2200-240A : 198~265 V ACModel MK2200-240AD : 85~265 V AC

110~340 V DC

Power consumption:AC auxiliary voltage : 6 ~ 10 VA typicalDC auxiliary voltage : 5 ~ 9 W typical

Binary Input:External binary input : 18 ~ 265 V DC 85 ~ 265 V AC

OUTPUT CONTACTS5 programmable contacts +1 IRF contact:Rated voltage : 250 V AC / DCContinuous carry : 5 A

Contact specification:Expected electrical life : 100,000 operations

at rated currentExpected mechanical life : 5 x 106 operations

Features

• Multifunction numerical relay

• Three-phase, low-set and high-set phase overcurrent

• Two sets of low-set and high-set setting for phase overcurrent

• Low-set and high-set earth fault

• Two sets of low-set and high-set setting for earth fault

• Circuit breaker failure protection

• Four selectable IDMT characteristic curves

• Definite time for low-set and high-set

• Numeric display of phase and earth fault currents

• Display of relay settings

• 9 non- volatile records of previous tripping currents

• Recording of relay start time

• Highly flexible programmable relay outputs

• Multifunction external digital input

• Isolated RS485 Modbus - RTU communication

• Selectable 50 Hz / 60 Hz

• ANSI code : 50P, 50G, 51P, 51G, 50BF

Com

bined Overcurrent &

Earth Fault R

elay

ACCURACYProtection thresholds : ± 3%Time delay : ± 2% with a minimum

of 30 msMeasurements : ± 3%Reset ratio : 95% typicalOvershoot time : less than 30 ms typical

EARTH-FAULT ELEMENTLow-set setting I o> : 0.05 ~ 1.0 x In ,

step 0.01

High-set setting I o>> : 0.05 ~ 10.0 x In , step 0.05

Time multiplier kt o> : 0.02 ~ 1.0 , step 0.01

Low set definite time t o>, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1

High set definite time t o>>, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1

OVERCURRENT ELEMENTLow-set setting I > : 0.10 ~ 2.50 x In ,

step 0.01

High-set setting I >> : 0.10 ~ 40 x In , 0.1 ~ 10 In : step 0.05 10 ~ 40 In : step 0.1

Time multiplier kt > : 0.02 ~ 1.0 , step 0.01

Low set definite time t >, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1

High set definite time t >>, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing

MECHANICAL Mounting : Panel mountingDimension (mm) : 142(w) x 165(h) x 198(d) Enclosure protection : IP54 at the panelApproximate weight : 2.9 kg

COMMUNICATIONRS485 Modbus - RTU

MK

2200

Page 6: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Com

bined Overcurrent &

Earth Fault R

elay

Ordering Information

MK2200 - 150D For 50/60 Hz system, auxiliary voltage 24 ~ 150 V DCMK2200 - 240A For 50/60 Hz system, auxiliary voltage 198 ~ 265 V ACMK2200 - 240AD For 50/60 Hz system, auxiliary voltage 84 ~ 265 V AC

or 110 ~ 340 V DC

MODEL DESCRIPTION

Case Dimensions

Normal Inverse Very Inverse Extremely Inverse

Long Time InverseTypical Application Diagram 1

Typical Application Diagram 2

142 mm

165

mm

Front

Panel Cutout

198 mm34 mm

136

mm

Side

139

±1 m

m

129 ±1 mm

1 100.1

1

10

0.05

0.1

0.2

0.3

0.40.50.60.70.80.91.0

20

k

t/s

I/I > 1 100.01

0.1

1

10

0.05

0.1

0.2

0.30.40.50.60.81.0

20

k

t/s

I/I >1 10

0.01

0.1

1

10

100

0.05 0.1 0.2

0.30.40.50.60.81.0

20

k

t/s

I/I >

t/s

I/I >

L1

L2

L3

Trip Contact

R1

R2

R3

R4

R5

Internal

Relay

Failure

Termination Resistor

N-

P+Communication

Cable Shield

RS485

External

Binary

Input

Auxiliary

input Uaux

1 343635

3837

4039

4241

2726

28302922

23

24

25

2

3

45

6

78

9

1011

COM

5 A

COM

5 A

COM

1 A

1 A

1 A

5 A

COM

1 A

5 A

12

32

31

33

13

14

LOAD

L2

L1

L3

N

Trip Contact

R1

R2

R3

R4

R5

Internal

Relay

Failure

Termination Resistor

N-

P+Communication

Cable Shield

RS485

External

Binary

Input

Auxiliary

input Uaux

1 343635

3837

4039

4241

2726

28302922

23

24

25

2

3

45

6

78

9

1011

COM

5 A

COM

5 A

COM

1 A

1 A

1 A

5 A

COM

1 A

5 A

12

32

31

33

13

14

LOAD

MK

2200

Page 7: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK1000A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThemal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK1000A-240A(6) : 198 ~ 265 V ACModel MK1000A-240AD(6) : 85 ~ 265 V AC 110 V DC ~ 340 V DCModel MK1000A-150D(6) : 24 ~ 150 V DCSupply frequency : 50 or 60 HzV A rating : 3 VA typical

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a

minimum of 50 ms

OUTPUT CONTACTS

Trip Contacts ( R1 & R2 )Rated voltage : 250V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations

at rated currentExpected mechanical life : 5 x 106 operations

Technical Data

Features

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Three-phase, low-set overcurrent

• Three-phase, high-set overcurrent

• Low-set earth-fault

• High-set earth-fault

• Definite time for low-set and high-set

• Five selectable IDMT characteristic curves

• Local display of measured and set values

• Programmable relay outputs

• Non-volatile fault values recording

• Complies with IEC 60255-26 standard

• ANSI Code : 50P, 50G, 51P, 51G

SETTING RANGESi ) Overcurrent elementsLow-set ( I > ) : 0.5 A to 10.0 A,

step 0.05 A : 10% to 200%,

step 1%Low-set time multiplier ( kt >): 0.05 to 1.0,

step 0.01Low-set definite time ( t > ) : 0.05 to 99s High-set ( I >> ) : 0.5 A to 99.9 A,

step 0.10 A or disable

: 10% to 1998%, step 2%

High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01

ii ) Earth-fault elementLow-set ( I o > ) : 0.10 A to 5.0 A,

step 0.05 A : 2% to 100%Low-set time multiplier(kt o>): 0.05 to 1.0,

step 0.01Low-set definite time ( t o > ) : 0.05 to 99sHigh-set ( I o >> ) : 0.10 A to 50 A,

step 0.10 A or disable

: 2% to 1000%, step 2%

High-set delay time ( t o >> ) : 0.05 sec to 2.5 sec, step 0.01

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display

and red indicators

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.8 kg

Com

bined Overcurrent &

Earth Fault R

elayM

K 1000A

Page 8: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Com

bined Overcurrent &

Earth Fault R

elay

Normal Inverse 1.3/10

Very Inverse

MK1000A

R1 R2

COM NC NOCOMNCNO

62 3 4 5

9 10 11 12 13 14

7

15

8

16

1

AuxNL

L1

L2

L3

N

LOA

D

Typical Application Diagram

Case Dimensions

Ordering Information

Normal Inverse

MK1000A-240A For 50Hz system, auxiliary voltage 198 ~ 265 V ACMK1000A-240AD For 50Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DCMK1000A-150D For 50Hz system, auxiliary voltage 24 ~ 150 V DCMK1000A-240AD6 For 60Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DCMK1000A-150D6 For 60Hz system, auxiliary voltage 24 ~ 150 V DC

MODEL DESCRIPTION

Long Time Inverse

Extremely Inverse

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Side

Panel Cutout

96 m

m

MK

1000A

Page 9: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK233A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK233A-240A (6) : 198 ~ 265 V ACModel MK233A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical

echnical Data

Features• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Three-phase, low-set overcurrent

• Three-phase, high-set overcurrent

• Local display of measured and set values

• Definite time for low-set and high-set

• Non-volatile fault value recording

• Programmable relay outputs

• Five selectable IDMT characteristic curves

• Complies with IEC 60255-26 standard

• ANSI Code : 50P, 51P

SETTING RANGES

Low-set ( I > ) : 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1%Low-set time multiplier ( kt > ) : 0.05 to 1.0, step 0.01Low-set definite time (t >) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)High-set ( I >> ) : 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2%High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum of

50 ms

OUTPUT CONTACTS (R1 & R2)

Rated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life: 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display and

red indicators

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.8 kg

Overcurrent R

elayM

K 233A

Page 10: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Overcurrent R

elay

Normal Inverse 1.3/10

Very Inverse

Aux

62 3 4 5

L

R1 R2

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO NC COM NC NO

16

1

MK 233A

LOA

D

Typical Application Diagram

Case Dimensions

Ordering Information

Normal Inverse

MK233A - 240A For 50 Hz system, auxiliary voltage198 ~ 265 V AC MK233A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK233A - 240A6 For 60 Hz system, auxiliary voltage198 ~ 265 V ACMK233A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

Long Time Inverse

Extremely Inverse

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Side

Panel Cutout

96 m

m

MK

233A

Page 11: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK234A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK234A-240A (6) : 198 ~ 265 V ACModel MK234A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

OUTPUT CONTACTS (R1 & R2)

Rated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

echnical Data

Overcurrent R

elayFeatures

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Three-phase, low-set overcurrent

• Three-phase, high-set overcurrent

• Local display of measured and set values

• Definite time for low-set and high-set

• Non-volatile fault value recording

• Programmable relay outputs

• Complies with IEC 60255-26 standard

• ANSI : 50P, 51P

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display

and red indicators

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.8 kg

SETTING RANGES

Low-set ( I > ) : 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1%Low-set definite time ( t > ) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)High-set ( I >> ) : 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2% High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01 M

K 234A

Page 12: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Overcurrent R

elay

Aux

62 3 4 5

L

R1 R2

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO NC COM NC NO

16

1

MK 234A

LOA

D

Typical Application Diagram Case Dimensions

Ordering Information

MK234A - 240A For 50 Hz system, auxiliary supply 198 ~ 265 V ACMK234A - 110A For 50 Hz system, auxiliary supply 94 ~ 127 V ACMK234A - 240A6 For 60 Hz system, auxiliary supply 198 ~ 265 V ACMK234A -110A6 For 60 Hz system, auxiliary supply 94 ~ 127 V AC

MODEL DESCRIPTION

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Side

Panel Cutout

96 m

m

MK

234A

Page 13: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK203A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK203A-240A : 198 ~ 265 V ACModel MK203A-110A : 94 ~ 127V ACSupply frequency : 50 HzVA rating : 3 VA typical

SETTING RANGES

Low-set ( I > ) : 2.0 A to 6.0 A : 40% to 120%Time multiplier ( TM ) : 0.05 to 1.0High-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time (t >>) : Instantaneous

TIME CURRENT CHARACTERISTIC CURVE

- Normal Inverse

echnical Data

Overcurrent R

elayFeatures

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Low-set inverse definite minimum time ( IDMT ) relay

• High-set instantaneous relay

• Separate low-set and high-set trip indicators

• Option to disable high-set relay

• Front panel access to test function

• Complies with IEC 60255-26 standard

• ANSI Code : 50P, 51P

OUTPUT CONTACTS

Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life: 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Approximate weight : 0.8 kg

MK

203A

Page 14: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Aux

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO NC

16

1

MK 203A

LOA

D

Typical Application Diagram

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO

AUX AUXMK 203A

NC

16

1 62 3 4 5

L N

9 10 11 12 13 14

7

15

8

COMNO

MK 202A

NC

16

1

R1

LOA

D

Combined IDMT Overcurrent & Earth Fault Relays

Ordering Information

MK203A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK203A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

Normal Inverse Case Dimensions

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

mFront

Side

Panel Cutout

96 m

m

Overcurrent R

elayM

K 203A

Page 15: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK204A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK204A-240A : 198 ~ 265 V ACModel MK204A-110A : 94 ~ 127V ACSupply frequency : 50 HzVA rating : 3 VA typical

SETTING RANGES

Low-set ( I > ) : 2.0 A to 6.0 A : 40% to 120%Time multiplier ( TM ) : 0.05 to 1.0High-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time (t >>) : Instantaneous

echnical Data

Features

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Low-set inverse definite time relay (IDT)

• High-set instantaneous relay

• Separate low-set and high-set trip indicators

• Option to disable high-set relay

• Front panel access to test function

• Complies with IEC 60255-26 standard

• ANSI Code : 50P, 51P

OUTPUT CONTACTS

Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life: 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Approximate weight : 0.8 kg

Overcurrent R

elayM

K 204A

Page 16: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Overcurrent R

elay

Aux

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO NC

16

1

MK 204A

LOA

D

Typical Application Diagram

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO

AUX AUXMK 204A

NC

16

1 62 3 4 5

L N

9 10 11 12 13 14

7

15

8

COMNO

MK 201A

NC

16

1

R1

LOA

D

Combined IDMT Overcurrent & Earth Fault Relays

Ordering Information

MK204A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK204A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

1.0

k

0.90.80.70.60.50.4

0.3

0.2

0.1

t/s

10

1

0.11 10 20 I/I>

Inverse Definite Time Case Dimensions

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

mFront

Side

Panel Cutout

96 m

m

MK

204A

Page 17: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK231A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK231A-240A (6) : 198 ~ 265 V ACModel MK231A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical

SETTING RANGES

Low-set ( I > ) : 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1%Low-set definite time ( t > ) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)High-set ( I >> ) : 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2%High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

OUTPUT CONTACTS

Rated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display

and red indicators

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.7 kg

Features

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Low-set earth-fault

• High-set earth-fault

• Local display of measured and set values

• Definite time for low-set and high-set

• Non-volatile fault value recording

• Programmable relay outputs

• Complies with IEC 60255-26 standard

• ANSI Code : 50N, 51N

Earth Fault R

elayM

K 231A

Page 18: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Fault R

elay

Aux

62 3 4 5

L

R1 R2

N

9 10 11 12 13 14

7

15

8

COMNO NC COM NC NO

16

1

MK 231A

L1

L2

L3

N

LOA

D

Typical Application Diagram 1 Typical Application Diagram 2

Ordering Information

MK231A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK231A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK231A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK231A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

Case Dimensions

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Side

Panel Cutout

96 m

m

Aux

62 3 4 5

L

R1 R2

N

9 10 11 12 13 14

7

15

8

COMNO NC COM NC NO

16

1

MK 231A

Core BalanceCurrent Transformer

L1

L2

L3

N

MK

231A

Page 19: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Typical Application Diagram 2Aux

62 3 4 5

L

R1

N

9 10 11 12 13 14

7

15

8

COMNO NC COM NC NO

16

R2

1

MK 232A

Core BalanceCurrent Transformer

L1

L2

L3

N

MK232A

Technical Data

RATINGSRated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLYModel MK232A-240A (6) : 198 ~ 265 V ACModel MK232A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical

SETTING RANGESLow-set ( I > ) : 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1%Low-set time multiplier ( kt > ) : 0.05 to 1.0, step 0.01Low-set definite time (t >) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99) High-set ( I >> ) : 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2%High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01

ACCURACYProtection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

OUTPUT CONTACTSRated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORSAuxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display

and red indicators

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.7 kg

Typical Application Diagram 1Aux

62 3 4 5

L

R1

N

9 10 11 12 13 14

7

15

8

COMNO NC COM NC NO

16

R2

1

MK 232A

L1

L2

L3

N

LOA

D

Features

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Low-set earth-fault

• High-set earth-fault

• Local display of measured and set values

• Definite time for low-set and high-set

• Non-volatile fault value recording

• Programmable relay outputs

• Five selectable IDMT characteristic curves

• Complies with IEC 60255-26 standard

• ANSI Code : 50N, 51N

Earth Fault R

elayM

K 232A

Page 20: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Fault R

elay

Normal Inverse 1.3/10

Very Inverse

Case Dimensions

Ordering Information

Normal Inverse

MK232A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK232A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK232A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK232A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

Long Time Inverse

Extremely Inverse

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Side

Panel Cutout

96 m

m

MK

232A

Page 21: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK201A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK201A-240A : 198 ~ 265 V AC Model MK201A-110A : 94 ~ 127 V AC Supply frequency : 50 HzVA rating : 3 VA typical

SETTING RANGES

Low-set ( I > ) : 0.1 A to 2.0 A : 2% to 40%Low-set delay time(DELAY): 0.05 sec to 1.0 secHigh-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time ( t >> ) : Instantaneous

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

OUTPUT CONTACTS

Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg

Features

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Low-set definite time relay

• High-set instantaneous relay

• Separate low-set and high-set indicators

• Option to disable the high-set relay

• Front panel access to the test function

• Complies with IEC 60255-26 standard

• ANSI Code : 50N, 51N

Earth Fault R

elayM

K 201A

Page 22: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Case Dimensions

Earth Fault R

elay

Aux

62 3 4 5

L

R1

N

9 10 11 12 13 14

7

15

8

COMNO NC

16

1

MK 201A

L1

L2

L3

N

LOA

D

Typical Application Diagram

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO

AUX AUXMK 204A

NC

16

1 62 3 4 5

L N

9 10 11 12 13 14

7

15

8

COMNO

MK 201A

NC

16

1

R1

LOA

D

Combined IDMT Overcurrent & Earth Fault Relays

96 mm

Front

96 m

m

90 mm70 mm

Side

91.0 ± 0.5 mm91

.0 ±

0.5

mm

Panel Cutout

Ordering Information

MK201A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK201A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTIONM

K 201A

Page 23: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK202A

Technical Data

RATINGS

Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous

AUXILIARY SUPPLY

Model MK202A-240A : 198 ~ 265 V ACModel MK202A-110A : 94 ~ 127V ACSupply frequency : 50 HzVA rating : 3 VA typical

SETTING RANGES

Low-set ( I > ) : 0.1A to 2.0 A : 2% to 40%Time multiplier ( TM ) : 0.05 to 1.0High-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time (t >>) : Instantaneous

ACCURACY

Protection thresholds : ± 5%Time delay : ± 5% with a minimum

of 50 ms

OUTPUT CONTACTS

Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

TIME CURRENT CHARACTERISTIC CURVE

- Normal Inverse

INDICATORS

Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg

Features

• Microprocessor based numerical relay

• Current measurement based on fundamental frequency

• Low-set inverse definite minimum time ( IDMT ) relay

• High-set instantaneous relay

• Separate low-set and high-set trip indicators

• Option to disable high-set element

• Front panel access to test function

• Complies with IEC 60255-26 standard

• ANSI Code : 50N, 51N

Earth Fault R

elayM

K 202A

Page 24: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Fault R

elay

Aux

62 3 4 5

L

R1

N

9 10 11 12 13 14

7

15

8

COMNO NC

16

1

MK 202A

L1

L2

L3

N

LOA

D

Typical Application Diagram

62 3 4 5

L

R1

N

L1

L2

L3

N

9 10 11 12 13 14

7

15

8

COMNO

AUX AUXMK 203A

NC

16

1 62 3 4 5

L N

9 10 11 12 13 14

7

15

8

COMNO

MK 202A

NC

16

1

R1

LOA

D

Combined IDMT Overcurrent & Earth Fault Relays

Ordering Information

MK202A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK202A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

Normal Inverse Case Dimensions

96 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

mFront

Panel Cutout

96 m

m

90 mm70 mm

Side

MK

202A

Page 25: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK300AMK300EA

Technical Data

AUXILIARY SUPPLYModel MK300A / 300EA -230A : 184 ~ 276 V ACModel MK300A / 300EA -110A : 94 ~ 127 V ACRated frequency : 50 HzVA rating : 3 VA typical

SETTINGSensitivity adjustment : 30mA, 50mA,

0.10~1.00A(Step=50mA) 1.00~10.0A (Step=1.00A)

Time delay adjustment : Instantaneous, 0.1~3.0sec (Step=0.1s)

PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%

RECORDFault record : 3 latest tripped fault

currents or “tSt” for manual test trip

Storage : Non-volatile memory

INPUT Remote Reset : N.O. dry contact *

OUTPUTS Trip contact : Activated during leakage

trip, manual test trip or ZCT connection error

Positive safety contact*: Activated when power-up and relay function correctly

Alarm contact* : Activated when measured leakage current exceeded 50% of IΔn.

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO)

3 A (NC)Expected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORSPre-fault alarm : Red indicator

(Normal blink)Time delay : Red indicator

(Fast blink)Leakage trip : 7-segment display

and red indicatorZCT connection error : 7-segment display

and red indicatorReal-time leakage current : 7-segment display

ZERO - PHASE CURRENT TRANSFORMERTo operate with Mikro’s ZCT series of current transformer

MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Enclosure protection : IP54 at the panelApproximate weight : 0.4 kg (excluding ZCT)

Features for MK 300A / 300EA

• Numerical earth leakage relay

• Programmable current sensitivity and time delay

• Detection of no connection to ZCT

• Relay trip indicator

• Relay alarm indicator

• Real-time leakage current display

• 50% pre-fault indicator

• Leakage fault current recording

• Standard DIN 96x96mm panel mounting

• Protected against nuisance tripping

Features for MK 300EA only

• Positive safety output contact

• Pre-fault alarm contact

• Remote reset function

Earth Leakage R

elayM

K 300A

/ 300EA

MK 300EA

MK 300A

Page 26: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Leakage R

elay

TRIPCONTACT

62 3 4 5 71

9 11 12 13 14 15

LNAUX

8

1610

LOAD

SHUNTTRIP

L1 L2 L3 N PE

MIKROZCT

MK300A

COMNONC

The EARTH wire must not pass through the ZCT

Typical Application Diagram For MK300A

Typical Application Diagram For MK300EA

TRIPCONTACT

62 3 4 5 71

9 11 12 13 14 15

LNAUX

8

1610

POSITIVE SAFETY CONTACT

LOAD

COM

L1 L2 L3 N PE

MK300EA

ALARMCONTACT

REMOTE RESET

CONTACTOR

MIKROZCT

NONCCOMNONC COMNO

The EARTH wire must not pass through the ZCT

Ordering Information

MK300A - 240AD For 50Hz system, auxiliary voltage 85~265VAC or 110~340VDCMK300EA - 240AD For 50Hz system, auxiliary voltage 85~265VAC or 110~340VDC MK300A - 230A For 50Hz system, auxiliary voltage 184~276VACMK300EA - 230A For 50Hz system, auxiliary voltage 184~276VACMK300A - 110A For 50Hz system, auxiliary voltage 94~127VACMK300EA - 110A For 50Hz system, auxiliary voltage 94~127VAC MK300A - 240AD6 For 60Hz system, auxiliary voltage 85~265VAC or 110~340VDCMK300EA - 240AD6 For 60Hz system, auxiliary voltage 85~265VAC or 110~340VDCMK300A - 230A6 For 60Hz system, auxiliary voltage 184~276VACMK300EA - 230A6 For 60Hz system, auxiliary voltage 184~276VACMK300A - 110A6 For 60Hz system, auxiliary voltage 94~127VACMK300EA - 110A6 For 60Hz system, auxiliary voltage 94~127VAC

MODEL DESCRIPTION

Case Dimensions

MK

300A / 300E

A

96 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Panel Cutout

96 m

m

90 mm70 mm

Side

Page 27: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK330A

Technical Data

AUXILIARY SUPPLYModel MK330A-230A : 184~276VACModel MK330A-110A : 94~127VACRated frequency : 50HzVA rating : 3VA typical

PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%

SETTINGSensitivity adjustment : 30mA, 50mA,

0.10~1.00A (Step=50mA) 1.00~10.0A (Step=1.00A)

Time delay adjustment: Instantaneous, 0.1~3.0sec (Step=0.1s)

Number of shots : 0~30 (Step=1, 0=Disable auto re-close function)

Dead time : 1~500sec (Step=1sec)

Persistent fault time : 0~500sec (Step=1sec, 0=Disable function)

Reclaim time : 0~500min (Step=1min, 0=Disable function)

Lockout auto reset time: 0~200hour (Step=1Hr, 0=Disable function)

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO)

3 A (NC)Expected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORSPre-fault alarm : Red indicator (Normal

blink)Time delay : Red indicator (Fast blink)Leakage trip : 7-segment display and

red indicatorRe-close lockout : 7-segment display and

red indicatorZCT connection error : 7-segment display and

red indicatorReal-time leakage current : 7-segment display

ZERO-PHASE CURRENT TRANSFORMERTo operate with Mikro’s ZCT series of current transformer

MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Enclosure protection : IP54 at the panelApproximate weight : 0.6 kg (excluding ZCT)

Programmable contact: Option 0 = Disable Option 1 = All (Option

2 to 6) Option 2 = ZCT error

Option 3 = Leakage trip, test trip,

re-close lockout Option 4 =Re-close

lockout Option 5 = Pre-fault alarm, leakage trip, test trip, re-close lockout

Option 6 = Re-close lockout, ZCT error

RECORDFault record : 3 latest tripped fault

currents or “tSt” for manual test trip

Storage : Non-volatile memory

INPUTRemote reset : N.O. dry contact

OUTPUTSTrip safe contact : Activated when the relay

is in normal power-up condition with the measured leakage current less than 0.85 IΔn.

Programmable contact: Activated according to user setting

Earth Leakage R

elayM

K 330A

Features

• Numerical auto-reclosing earth leakage relay

• Incorporated positive safety feature into trip contact

• One programmable contact for flexibility

• Detection of no connection to ZCT

• Relay trip / alarm indicator

• Real-time leakage current display

• Leakage fault current recording

• Remote reset function

• Standard DIN 96 x 96mm panel mounting

• Protected against nuisance tripping

Page 28: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Leakage R

elay

Ordering Information

MK330A-230A For 50Hz system, auxiliary voltage 184~276VAC

MK330A-110A For 50Hz system, auxiliary voltage 94~127VAC

MK330A-230A6 For 60Hz system, auxiliary voltage 184~276VAC

MK330A-110A6 For 60Hz system, auxiliary voltage 94~127VAC

MODEL DESCRIPTION

Case Dimensions Typical Application Diagram

TRIP SAFECONTACT*

62 3 4 5 71

9 11 12 13 14 15

LNAUX

8

1610

PROGRAMMABLE CONTACT

LOAD

COM

L1 L2 L3 N PE

MK330A

REMOTE RESET

CONTACTOR

MIKROZCT

NONCCOMNONC

The EARTH wire must not pass through the ZCT

* The trip safe contact is activated (terminal 10-11 closed) when

the relay is in normal power-up condition with the measured

leakage current less than 0.85 IΔn.

MK

330A

96 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Panel Cutout

96 m

m

90 mm70 mm

Side

Page 29: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MK302AMK301AMK301E

Technical Data

AUXILIARY SUPPLY

Model MK301A / 302A -240A : 198 ~ 265 V ACModel MK301A / 302A -110A : 94 ~ 127 V ACRated frequency : 50 / 60 HzVA rating : 3 VA typical

SETTING RANGES

Sensitivity adjustment : 0.03 A to 30 ADelay time adjustment : 0 sec to 3.0 sec

PERFORMANCE

Setting accuracy : -15% to +0%Timing accuracy : ±5%

OUTPUT CONTACTS

Contact arrangement : 1 x manual reset type : 1 x safety contact* : NC and NO contacts

availableRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INPUTS

Remote Test* / Reset Inputs* : N.O. dry contact

INDICATORS

Auxiliary supply : Green indicatorTime delay : Red indicatorTrip : Red indicatorReal-time leakage current : Red indicator

Features

• Trip starting indicator

• Detection of no connection to current transformer for extra safety

• Relay tripped indicator

• High immunity to electrical interference

Features for MK 302A only

• Safety output contact

• Earth leakage level indicators

• Remote reset and remote test functions

Earth Leakage R

elayM

K 302A

/ 301A / 301E

ZERO - PHASE CURRENT TRANSFORMER

To operate with Mikro’s ZCT series of current transformer

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg (excluding ZCT)

* Applicable to MK302A series only

** Applicable to MK301E series only

MK 302A

MK 301A

MK 301E

Page 30: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Leakage R

elay

Typical Application Diagram

L1

L2

L3

N

2 3 4 5 6

10

1

9 11 12 13 14

7

15

8

16

L NAUX

TRIP CONTACT

MK301A or MK302A

LOAD

SHUNTTRIP

NO NC COM

PE

The EARTH wire must not pass through the ZCT

L1

L2

L3

N

1 2 3 4 5 6

9 10 11 12 13 14

7

15

8

16

L NAUX

TRIP CONTACT

LOAD

CONTACTOR

SAFETY CONTACT*

REMOTETEST*

REMOTE RESET*

COM COM NCNC NONO

PE

The EARTH wire must not pass through the ZCT

MK302A

L1

L2

L3

N

1 2 3 4 5 6

9 10 11 12 13 14

7

15

8

16

L NAUX

TRIP CONTACT TRIP CONTACT 2**

LOAD

SHUNTTRIP

NO NC COM NC NOC OM

PE

The EARTH wire must not pass through the ZCT

MK301E

Case Dimensions

96 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Panel Cutout

96 m

m

90 mm70 mm

Side

Ordering Information

MK301A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC MK301A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK302A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK302A -110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK301E - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK301E -110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK301A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V AC MK301A - 110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V ACMK302A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK302A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V ACMK301E - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK301E -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC

MODEL DESCRIPTION

MK

302A / 301A

/ 301E

Page 31: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DIN330

Technical Data

AUXILIARY SUPPLYModel DIN330-230 A(6) : 184 ~ 276 V ACRated frequency : 50 or 60 HzVA rating : 3 VA typical

PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%

SETTINGSensitivity adjustment : 30 mA, 50 mA, 0.10 A –1.00 A

(Step = 50 mA), 1.00 A – 10.0 A

(Step = 1.00 A)Time delay adjustment: Instantaneous,

0.1s – 3.0s Step = 0.10 sec.

Number of shots : 0 - 30. Step = 1. 0 = Disable auto reclose function

Dead time : 1 - 500 sec. Step = 1 sec.

Permanent fault time : 0 - 500 sec. Step = 1 sec. 0 = Disable function

Reclaim time : 0 - 500 minute Step = 1 min 0 = Disable function

Lockout auto reset time: 0 - 200 hour Step = 1 Hrs 0 = Disable function

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO) 3 A (NC)Expected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORS50% pre-fault alarm : Red indicator (Normal

blink)Time delay : Red indicator (Fast blink)Leakage trip : 7-segment display and

red indicatorReclose lockout : 7-segment display and

red indicatorZCT fault : 7-segment display and

red indicatorReal time leakage current : 7-segment display

To operate with Mikro’s ZCT series of current transformer

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICALMounting : Panel mountingDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.4 kg (excluding ZCT)

Programmable contact : Option 0 = Disable Option 1 = All (Option 2 to 6) Option 2 = ZCT error Option 3 = Leakage trip, test trip, re-close lockout Option 4 = Re-close lockout Option 5 = Pre-fault alarm, leakage trip, test trip, reclose lockout Option 6 =Re-close lockout, ZCT error

RECORDFault record : 3 latest tripped fault

currents or “tSt” for manual test trip

Storage : Non-volatile memory

INPUTRemote reset : N.O. dry contact

OUTPUTSTrip safe contact : Activated when the relay

is in normal power-up condition with the

measured leakage current less than 0.85 IΔn.

Programmable contact: Activated according to user setting

Earth Leakage R

elayD

IN 330

Features

• Numerical auto-reclosing earth leakage relay

• Incorporated positive safety feature into trip contact

• Detection of no connection to ZCT

• Relay trip / alarm indicator

• Real-time leakage current display

• Leakage fault current recording

• Remote reset function

• Standard 35mm DIN rail mounting

• Protected against nuisance tripping

Page 32: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Leakage R

elay

Ordering Information

DIN330 - 230 A For 50 Hz system, auxiliary voltage 230 V AC DIN330 - 230 A6 For 60 Hz system, auxiliary voltage 230 V AC

MODEL DESCRIPTION

Case Dimensions

Front

Side

71 mm

20 mm

45 mm

20 mm

70 mm

85 mm

30 mm 20 mm 20 mm

TRIP SAFE CONTACT PROGRAMMABLE CONTACT

LOAD

L1

L2

L3 N

62 3 4 5 71

8 9 10 11 12 13 14

L NAUX

CONTACTOR

MIKROZCT

DIN330

REMOTERESET

COM NO NC COM NO NC

PE

The EARTH wire must not pass through the ZCT

Typical Application Diagram

* The trip safe contact is activated (terminal 9-10 closed) when

the relay is in normal power-up condition with the measured

leakage current less than 0.85 IDn.

DIN

330

Page 33: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DIN310DIN310E

Technical Data

AUXILIARY SUPPLYDIN310-230 A(6) : 184 ~ 276 V AC DIN310E-230 A(6) : 184 ~ 276 V ACRated frequency : 50 or 60 HzVA rating : 3 VA typical

PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%

SETTINGSensitivity adjustment : 30mA, 50mA,

0.10~1.00A (Step=50mA) 1.00~10.0A (Step=1.00A)

Time delay adjustment: Instantaneous, 0.1~3.0sec

Step=0.10 sec

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO)

3 A (NC)Expected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

RECORDFault record : 3 latest tripped fault

currents or “tSt” for manual test trip

Storage : Non-volatile memory

INPUTRemote reset* : N.O. dry contact

OUTPUTSTrip Contact : Activated if relay tripped

or ZCT faultPositive safety contact* : Activated when ZCT is

connected properly to the relay

Pre-fault alarm contact*: Activated when leakage current exceeded 50% of sensitivity setting

INDICATORS50% pre-fault alarm : Red indicatorTime delay : Red indicatorLeakage trip : 7-segment display and red

indicatorZCT fault : 7-segment display and red

indicatorReal time leakage current: 7-segment display

Earth Leakage R

elayD

IN 310 / 310E

Features

• Numerical earth leakage relay

• Programmable current sensitivity and time delay

• Detection of no connection to ZCT

• Relay trip indicator

• Relay alarm indicator

• Real-time leakage current display

• Leakage fault current recording

• 50% pre-fault indicator

• Standard DIN rail mounting

• Protection against nuisance tripping

Features For DIN 310E only

• Positive safety output contact

• 50% pre-fault output contact

• Remote reset function

To operate with Mikro’s ZCT series of current transformer

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICALMounting : Panel mountingDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.4 kg (excluding ZCT)

* Applicable to DIN310E series only

Page 34: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Case Dimensions

Earth Leakage R

elay

Ordering Information

DIN310 - 230 A For 50 Hz system, auxiliary voltage 230 V AC DIN310E - 230 A For 50 Hz system, auxiliary voltage 230 V ACDIN310 - 230 A6 For 60 Hz system, auxiliary voltage 230 V AC DIN310E - 230 A6 For 60 Hz system, auxiliary voltage 230 V AC

* 60Hz system, auxiliary voltage 110V AC model available upon special request.

MODEL DESCRIPTION

Front

Side

71 mm

20 mm45 m

m

20 mm

70 mm

85 mm

30 mm 20 mm 20 mmTRIP CONTACT SAFETY CONTACT

LOAD

L1

L2

L3 N

62 3 4 5 71

8 9 10 11 12 13 14

L NAUX

CONTACTOR

MIKROZCT

DIN310E

REMOTERESET

ALARM CONTACT

NO NC NCCOM COM NO

PE

The EARTH wire must not pass through the ZCT

TRIPCONTACT

LOAD

L1

L2

L3 N

62 3 4 5 71

8 9

COM NO NC

10 11 12 13 14

L NAUX

SHUNTTRIP

MIKROZCT

DIN310

PE

The EARTH wire must not pass through the ZCT

Typical Application Diagram For DIN 310E

Typical Application Diagram For DIN 310

DIN

310 / 310E

Page 35: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DIN300DIN300E

Technical Data

AUXILIARY SUPPLYModel DIN300 / 300E -240A : 198 ~ 265 V ACModel DIN300 / 300E -110A : 94 ~ 127 V ACRated frequency : 50 / 60 HzVA rating : 3 VA typical

SETTING RANGESSensitivity setting : 30 mA, 50 mA, 75 mA,

100 mA, 125 mA, 150 mA, 200 mA, 250 mA, 300 mA, 500 mA, 750 mA, 1 A, 1.25 A, 1.5 A, 2 A, 2.5 A, 3 A, 5 A, 7.5 A, 10 A, 12.5 A, 15 A, 20 A, 25 A, 30 A.

Time delay setting : Instantaneous, 50 ms, 100 ms, 150 ms, 250 ms, 350 ms, 500 ms, 1 s, 3 s.

PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : DIN rail mountingDimension (mm) : 71(w) x 85(h) x 70(d)

Approximate weight

:

0.4 kg (excluding ZCT)

* Applicable to DIN300E model only

OUTPUT CONTACTSContacts ( Trip / 50% pre-fault* )Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INPUTRemote test* / Reset inputs* : N.O. dry contacts

To operate with Mikro’s ZCT series of current transformer

INDICATORSAuxiliary supply : Green indicatorTime delay : Red indicatorTrip : Red indicatorLeakage current* : 5 red indicators for

leakage levels

Earth Leakage R

elayD

IN 300 / 300E

Features

• 25 selectable sensitivity settings: 30 mA to 30 A

• 9 selectable time delays: 0ms to 3s

• Earth leakage level indicators

• Detection of no connection to ZCT

• Relay tripped indicator

• Trip starting indicator

• Protected against nuisance tripping

Features For DIN 300E only

• 50% pre-fault output contact

• Remote test and remote reset functions

Page 36: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Earth Leakage R

elay

Case Dimensions

Ordering Information

DIN300 - 240A For 50 Hz system, auxiliary voltage 240 V AC DIN300 - 110A For 50 Hz system, auxiliary voltage 110 V ACDIN300E - 240A For 50 Hz system, auxiliary voltage 240 V AC DIN300E - 110A For 50 Hz system, auxiliary voltage 110 V ACDIN300 - 240A6 For 60 Hz system, auxiliary voltage 240 V AC DIN300 - 110A6 For 60 Hz system, auxiliary voltage 110 V ACDIN300E - 240A6 For 60 Hz system, auxiliary voltage 240 V AC DIN300E - 110A6 For 60 Hz system, auxiliary voltage 110 V AC

MODEL DESCRIPTION

71mm

71mm

30mm 20mm 20mm

45mm

85mm

20mm

20mm

Front view

Side view

L1

L2

L3 N

1 2 3 4 5 6

8 9 10 11 12 13

7

14

L NAUX

S2

S1

TRIP CONTACT50% PRE-FAULT CONTACT

LOAD

SHUNTTRIP

REM

OTE

RES

ET

REM

OTE

TES

T

COMCOM NO NCNCNO

PE

The EARTH wire must not pass through the ZCT

L1

L2

L3 N

1 2 3 4 5 6

8 9 10 11 12 13

7

14

L NAUX

S2

S1

TRIP CONTACT

LOAD

SHUNTTRIP

COM NO NC

PE

The EARTH wire must not pass through the ZCT

Typical Application Diagram For DIN 300E

Typical Application Diagram For DIN 300

DIN

300 / 300E

Page 37: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

ZCT40SZCT60SZCT80SZCT120SZCT210S

B

A C

D

G

F

E

Front

Bottom

DIMENSION

(mm) ZCT Model

40S 60S 80S 120S 210S

A 40 60 80 120 210 B 89 105 130 180 310 C 94 110 135 195 311 D 6 6 6 6 6 E 37 37 37 37 37 F 75 87 112 159 292 G 27 27 27 27 18

Earth Leakage R

elayZC

T 40S / 60S

/ 80S / 120S

/ 210S

Case Dimensions

Calculation to determine Inner Diameter of ZCT required

Ordering Information

ZCT 40S 40 14 12 ZCT 60S 60 23 21 ZCT 80S 80 32 29 ZCT 120S 120 51 46 ZCT 210S 210 93 83

ZCT40S 40mm inner diameter 0.16 kgZCT60S 60mm inner diameter 0.20 kgZCT80S 80mm inner diameter 0.28 kgZCT120S 120mm inner diameter 0.57 kgZCT210S 210mm inner diameter 1.5 kg

D d3, 3 wire d4, 4 wire

MODEL ZCT inner Up till wire Up till wire diameter (mm) diameter (mm) diameter (mm)

MODEL DESCRIPTION WEIGHT

40S

60S

80S

120S 210S

D

d3

3 wire

D

d4

4 wire

Example:

For a single core CU / PVC insulated, non-sheathed 450 / 750 V 50mm2 conductor, it’s nominal overall diameter is 11.7mm. To pass 4 wires through the ZCT, we can use ZCT40S as the maximum diameter it can support is up till 12mm.

Page 38: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DVMFeatures

• Built-in selector switch

• Easy-to-read, 14.2mm digit display

• DIN size casing

Technical Data

Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V ACVA rating : 3 VAInput frequency : 47 ~ 66 HzMaximum input voltage : 500 VrmsApproximate weight : 0.6 kg

Digital P

ower M

eter

Aux SupplyAC 240 V

DVM360 Series

62 3 4 5

L1

L2

L3

N

7 8 9 10 11 12

1

Typical Application Diagram

Aux SupplyAC 240 V

DVM100 Series

62 3 4 5

7 8 9 10 11 12

1

L

N

Case Dimensions

96 m

m

96 mm

Front

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Panel Cutout

91.5 mm

87 mm

Side

Ordering Information

DVM360 - 240A Auxiliary voltage 240 V AC DVM100 - 240A Auxiliary voltage 240 V ACDVM360 - 110A Auxiliary voltage 110 V ACDVM100 - 110A Auxiliary voltage 110 V AC

MODEL DESCRIPTION

DVM3VV

L1

L2

L3

N

TypypiTT cal Apppplic

DV

M

Page 39: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DAMFeatures

• Built-in selector switch

• Easy-to-read, 14.2mm digit display

• DIN size casing

• Wide selection of current transformer (CT) ratio

Technical Data

Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V ACVA rating : 3 VAInput frequency : 47 ~ 66 HzMaximum input : 6 A continuousAmmeter CT ratio : .../5 AClass : 1.0Approximate weight : 0.7 kg

Aux SupplyAC 240 V

DAM330 / 3000 Series

62 3 4 5

L1

L2

L3

7 8 9 10 11 12

1

Typical Application Diagram

Aux SupplyAC 240 V

DAM100 / 1000 Series

62 3 4 5

7 8 9 10 11 12

1

L

N

Case Dimensions

96 m

m

96 mm

Front

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Panel Cutout

91.5 mm

87 mm

Side

L1

TypypiTT cal App

Digital P

ower M

eterD

AM

Page 40: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

For primary current from 60 A to 500 A

DAM 330 - XXXXDAM 100 - XXXX

Order number

Example: Model DAM 330 - 0060 for digital ammeter with CT ratio 60 / 5 A.

0060

ORDER NUMBERModel DAM 330 & DAM 100

*CT RATIO

60 / 5 A

0100 100 / 5 A

0150 150 / 5 A

0200

0250

0300

0400

0500

200 / 5 A

250 / 5 A

300 / 5 A

400 / 5 A

500 / 5 A

For primary current from 600 A to 5000 A

DAM 3000 - XXXXDAM 1000 - XXXX

Order number

600

ORDER NUMBERModel DAM3000 & DAM1000

*CT RATIO

600 / 5 A

800 800 / 5 A

1000 1000 / 5 A

1200

1500

1600

2000

2400

1200 / 5 A

1500 / 5 A

1600 / 5 A

2000 / 5 A

2400 / 5 A

2500 2500 / 5 A

3000 3000 / 5 A

3200 3200 / 5 A

3500 3500 / 5 A

4000 4000 / 5 A

4500 4500 / 5 A

5000 5000 / 5 A

*CT : Current Transformer For other CT ratio, please contact

the manufacturer.

DAM330 - xxxx - 240A

MODEL DESCRIPTION

Auxiliary voltage 240 V AC

DAM100 - xxxx - 240A Auxiliary voltage 240 V AC

DAM330 - xxxx - 110A Auxiliary voltage 110 V AC

DAM100 - xxxx - 110A Auxiliary voltage 110 V AC

DAM3000 - xxxx - 240A Auxiliary voltage 240 V AC

DAM1000 - xxxx - 240A Auxiliary voltage 240 V AC

DAM3000 - xxxx - 110A Auxiliary voltage 110 V AC

DAM1000 - xxxx - 110A Auxiliary voltage 110 V AC

DAM330

MODEL

/ SERIES

DAM3000

DAM100

WITH

SELECTOR

WITHOUT

SELECTOR

A

UNIT

A

A

A

DISPLAY

FORMAT

DAM1000

Ordering Information

Digital P

ower M

eterD

AM

Page 41: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DPM680FeaturesMeasurement Parameters: • Phase & Line Voltages (L-N) • Phase Current & Neutral Current • Bidirectional kW, kVAR & kVA• Bidirectional kWh, kVARh & kVAh• Frequency • Total & Displacement Power Factor• Voltage Total Harmonic Distortion• Current Total Harmonic Distortion• Avg. and Max. Thermal Current Demand• Avg. and Max. Power (kW, kVA, kVAR) Demand• Current Sequence Components• Voltage Sequence Components

TFT Colour LCD Display Serial RS-485 Modbus RTU Modbus TCP/IPBuilt-in WebserverVoltage & Current Waveform DisplayVoltage & Current Harmonics Display

Digital P

ower M

eter

Technical Data

WIRING SYSTEMS3-phase 4-wire system 3-phase 3-wire system

Nominal current : 5 A Min. measurement : 5 mA Accuracy : 0.2% of full scaleBurden : < 0.05 VA at 5 AMeasurement range : 10 APulsed withstand : 100 A for 1 secCT primary : 5 ~ 50,000 A

Nominal phase voltage : 0 ~ 300 V AC Minimum measurement : 10 V Accuracy : 0.2% at full scalePhase voltage via VT : 60 ~ 50,000 V

POWER MEASUREMENT Real power, apparent power, reactive power Accuracy : 0.5%

POWER FACTOR MEASUREMENT Total and displacement power factor Accuracy : 0.5%

POWER & THERMAL CURRENT DEMANDInterval : 1 ~ 30 mins

VOLTAGE AND CURRENT SEQUENCECOMPONENTSPositive, negative and zero sequence

FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz Accuracy : 0.2%

ENERGY MEASUREMENT ACCURACYActive : IEC 62053-22 class 0.5 Reactive : IEC 62053-23 class 2

HARMONICS DISPLAY Fundamental up to 32nd order

VOLTAGE & CURRENT WAVEFORMDISPLAY Simultaneous 3-phase voltage orcurrent waveforms

COMMUNICATIONProtocol : Modbus RTU Interface : Isolated RS485

Protocol : Modbus TCP/IPInterface : Ethernet 10M/100M BaseT

Protocol : HTTP ServerInterface : Ethernet 10M/100M BaseT

AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC Power consumption : 3W typicalSustained overload : 500 V AC

ENVIRONMENTAL CONDITIONSOvervoltage category : IVPollution degree : 2Operating temperature : -10˚C ~ +55˚C Storage temperature : -20˚C ~ +70˚CHumidity : 0 – 95%,

non condensing

MECHANICAL Mounting : according to DIN 43700 /

ANSI C39.1Dimension (mm) : 96(w) x 96(h) x 100(d) Enclosure protection : IP63 at the panel

IP20 at the bodyApproximate weight : 0.5 kg

DP

M 680

Page 42: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Ordering Information

Test Standards

DPM 680-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC

Safety requirements.

EMC requirements.

MODEL DESCRIPTION

IEC 61010-1

IEC 61326-1

Case DimensionsTypical Application Diagrams

101.6±0.5mm

91±0.5mm

91±0.5mm

Cut-Out Recommendations

Digital P

ower M

eter

3-PHASE 4-WIRE SYSTEM : 4 CTs, Direct V Input

3-PHASE 3-WIRE SYSTEM : 3 CTs, 3 VTs 3-PHASE 3-WIRE SYSTEM : 3 CTs, Direct V Input

3-PHASE 4-WIRE SYSTEM : 3 CTs, Direct V Input

L3

L2

L1

S2

S1

S2

S1

S2

S1

l3

GND

l2

l1

S2

S1ln

Ln

L3L2L1 Ln

90~415 V AC /100~300 V DCAUX

RS 485Modbus-RTU

Ethernet

L3

L2

L1

S2

S1

S2

S1

S2

S1

l3

GND

l2

l1

S2

S1ln

Ln

L3L2L1 Ln

90~415 V AC /100~300 V DCAUX

RS 485Modbus-RTU

Ethernet

L3

L2

L1

S2

S1

S2

S1

S2

S1

l3

GND

l2

l1

S2

S1ln

Ln

L3L2L1

90~415 V AC /100~300 V DCAUX

RS 485Modbus-RTU

GND

Ethernet

L3

L2

L1

S2

S1

S2

S1

S2

S1

l3

l2

l1

S2

S1ln

Ln

L3L2L1

90~415 V AC /100~300 V DCAUX

RS 485Modbus-RTU

Ethernet

GND

LOAD

LOAD

LOAD

LOAD

Front

Rear

Side

96 mm

83 mm

17 mm

100 m

m

96 mm

90 mm

86 mmea

DP

M 680

Page 43: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DPM380DPM380B

Features

LCD display with back lighting

Modbus-RTU communication

(for DPM380 only)

MEASUREMENT PARAMETERS:

• Phase Voltage (L-N)

• Line Voltage (L-L)

• Phase Current and Neutral Current

• Bidirectional kW (per phase & total)

• Bidirectional kVAR (per phase & total)

• Bidirectional kVA (per phase & total)

• Frequency

• Power Factor (per phase & total)

• Energy (+ and - ) for kWh, kVARh and kVAh

• THD Phase Voltage ( L-N )

• THD Phase Current

• Active Power (kW) Demand

Technical Data

DISPLAY TYPELCD display

MEASUREMENTS3-phase 4-wire system 3-phase 3-wire system

CURRENT MEASUREMENTCT primary : 5 ~ 8000 ACT secondary : 5 AMinimum measurement : 5 mAAccuracy : 0.5% from 1A to 6 A (secondary)Burden : < 0.05 VA at 5 ASustained overload : 6 A

VOLTAGE MEASUREMENTNominal phase voltage : 20 ~ 300 V AC Minimum measurement : 10 V Accuracy : 0.5% at full scalePhase voltage via VT : 60 ~ 33,000 V

POWER MEASUREMENTReal power, apparent power, reactive power measurementMeasuring updating period : 1 sAccuracy : 1.0%

ACTIVE POWER DEMANDInterval : 1 ~ 30 mins

POWER FACTOR MEASUREMENTTotal and displacement power factor Accuracy : 1.0%

FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 HzMeasurement updating period : 1sAccuracy : 0.5%

ENERGY ACCURACYActive (according to IEC 62053-21) : class 1Reactive (according to IEC 62053-23) : class 2

AUXILIARY POWER SUPPLYAC voltage : 90 ~ 415 V ACFrequency : 50 / 60 HzDC voltage : 100 ~ 300 V DCPower consumption : <3 VA

COMMUNICATIONHardware interface : Isolated RS485Protocol : Modbus-RTUBaud rate : 2400, 4800, 9600, 19200, 38400

ENVIRONMENTAL CONDITIONSOperating temperature : -10˚C ~ +55˚CStorage temperature : -20˚C ~ +70˚C Humidity : 0 – 95%,

non condensing

MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 100(d) Approximate weight : 0.5 kg

Digital P

ower M

eterD

PM

380 / 380B

• Maximum Active Power (kW) Demand

Page 44: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Typical Application Diagram

Ordering Information

Electromagnetic Compatibility (EMC)

DPM 380-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with RS 485DPM 380B-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC

Immunity for industrial environments.

Emission standard for industrial environments.

MODEL DESCRIPTION

Part 6-2: Generic Standards IEC61000-6-2

Part 6-4: Generic Standards IEC61000-6-4

L3

L2

L1

S2

S1

S2

S1

S2

S1

l3

GND

l2

l1

S2

S1ln

Ln

L3L2L1 Ln

90~415 V AC /100~300 V DCAUX

RS 485Modbus-RTU

* For DPM380 only

+

-

GND

3-PHASE 4-WIRE SYSTEM WITH 4 CTs CONNECTION

LOAD

L3

L2

L1

S2

S1

S2

S1

S2

S1

l3

GND

l2

l1

S2

S1ln

Ln

L3L2L1 Ln

90~415 V AC /100~300 V DCAUX

3-PHASE 4-WIRE SYSTEM WITH 3 CTs CONNECTION

RS 485Modbus-RTU

* For DPM380 only

+

-

GND

LOAD

Case Dimensions

Front

Rear

Side

96 mm

83 mm

17 mm

100 m

m1

96 mm

90 mm

86 mm

86 mm

ea

101.6±0.5mm

91±0.5mm

91±0.5mm

Cut-Out Recommendations

Digital P

ower M

eterD

PM

380 / 380B

Page 45: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

DM38Features

LCD display with back lighting

Modbus-RTU communication

DIN rail type

MEASUREMENT PARAMETERS:

• Phase Voltage ( L-N )

• Line Voltage ( L-L )

• Phase Current

• Bidirectional kW (per phase & total)

• Bidirectional kVAR (per phase & total)

• Bidirectional kVA (per phase & total)

• Frequency

• Power Factor (per phase & total)

• Energy (+ and - ) for kWh, kVARh and kVAh

• THD Phase Voltage ( L-N )

• THD Phase Current

Technical Data

DISPLAY TYPELCD display

MEASUREMENTS3-phase 4-wire system

CURRENT MEASUREMENTCT primary : 5 ~ 8000 ACT secondary : 5 AMinimum measurement : 10 mAAccuracy : 0.5% from 1A to 6 A (secondary)Burden : < 0.03 VA at 5 ASustained overload : 6 A

VOLTAGE MEASUREMENTNominal phase voltage : 70 ~ 300 V AC Minimum measurement : 10 V Accuracy : 0.5% at full scale

POWER MEASUREMENTReal power, apparent power, reactive power measurementMeasuring updating period : 1 sAccuracy : 1.0%

POWER FACTOR MEASUREMENTTotal and displacement power factor Accuracy : 1.0%

FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 HzMeasurement updating period : 1sAccuracy : 0.5%

ENERGY ACCURACYActive (according to IEC 62053-21) : class 1Reactive (according to IEC 62053-23) : class 2

POWER SUPPLYSelf supplied : 100 ~ 240 V ACFrequency : 50 / 60 HzPower consumption : <3 VA

COMMUNICATIONHardware interface : Isolated RS485Protocol : Modbus-RTUBaud rate : 2400, 4800, 9600, 19200, 38400

ENVIRONMENTAL CONDITIONSOperating temperature : -10˚C ~ +55˚CStorage temperature : -20˚C ~ +70˚CHumidity : 0 – 95%,

non condensing

MECHANICALMounting : DIN railDimension (mm) : 65(w) x 85(h) x 50(d)Approximate weight : 0.3 kg

Digital P

ower M

eterD

M 38

Page 46: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Digital P

ower M

eter

65 mm

85 mm

45.5 mm

71 mm

Front

15.5 mm

50 mm

Side

Case Dimensions

Typical Application Diagram

1 2 3 4 5 6

S1 S2 S1 S2 S1 S2

7 8 9 10 11

12 13 14 15 16 17 18 19 20 21 22

LnL3

L2

L1

RS 485Modbus-RTU

NOTE: Current transformer secondaryterminal MUST NOT be earthed.

S1P1

P2S2 DM38

120 Ohm

I1 I2 I3

L3L1 L2 Ln

DM 38 CONNECTION DIAGRAM

!X

+-GN

D

LOA

D

Ordering Information

Electromagnetic Compatibility (EMC)

DM 38-240A Self Powered 100~240 V AC

Immunity for industrial environments.

Emission standard for industrial environments.

MODEL DESCRIPTION

Part 6-2: Generic Standards IEC61000-6-2

Part 6-4: Generic Standards IEC61000-6-4

DM

38

Page 47: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MU2300 Features

• Multifunction numerical voltage protection relay

• time or inverse-time characteristic

• time

• or inverse-time characteristic

• time

• Negative sequence overvoltage protection (U2>)

• Neutral displacement / residual overvoltage protection (U0characteristic

• Can be used in single-phase or three-phase operation

• Multi-function isolated digital input with wide input voltage range

• Fault record and event code recording

• Five programmable voltage-free output contacts

• Isolated RS485 Modbus - RTU communication

• ANSI Code : 27, 47, 59, 60

Voltage Relay

MU

2300

Introduction

The MU2300 is a microprocessor based numerical relay for voltage protection functions in electrical distribution network.

Technical Data

INPUTS

Measuring input:

Rated voltage input : 57 ~ 130 VRated frequency : 50 / 60 Hz

Rated auxiliary voltage:

Model MU2300-150D : 24 ~ 150 V DCModel MU2300-240AD : 85 ~ 265 V AC

110 ~ 340 V DC

Power consumption:

AC auxiliary voltage : 6 ~ 10 VA typicalDC auxiliary voltage : 5 ~ 9 W typical

Binary Input:

External binary input : 85 ~ 265 V AC/DC

COMMUNICATION

RS485 Modbus - RTU

OUTPUT CONTACTS

5 programmable contacts +1 IRF contact:

Rated voltage : 250 V AC / DCContinuous carry : 5 AMake and carry for 0.2 s : 30 AExpected electrical life : 100,000 operations

at rated currentExpected mechanical life : 5 x 106 operations

UNDER-VOLTAGE ELEMENT

Low set setting U< : 5 - 130 VHigh set setting U<< : 5 - 130 VTime multiplier, TMS : 0.5 - 100

: 0 - 600 s : 0 - 600 s

OVER-VOLTAGE ELEMENT

Low set setting U> : 5 - 200 VHigh set setting U>> : 5 - 260 VTime multiplier, TMS : 0.5 - 100

: 0 - 600 ste time tU>> : 0 - 600 s

NEGATIVE SEQUENCE OVER-VOLTAGE

ELEMENT

Negative sequence over-voltage setting, U2> : 5 - 200 V

Time multiplier, TMS : 0.5 - 1002>

: 0 - 600 s

RESIDUAL OVER-VOLTAGE ELEMENT

Residual over-voltage setting, U0> : 0.5 - 130 VTime multiplier, TMS : 0.5 - 100

0>: 0 - 600 s

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 142(w) x 165(h) x 198(d)Enclosure protection : IP54 at the panelApproximate weight : 2.7 kg

Page 48: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Voltage Relay

11

1010

100100

00 0.10.1 0.20.2 0.30.3 0.40.4 0.50.5 0.60.6 0.70.7 0.80.8 0.90.9 11TMS=1

TMS=5

TMS=3

TMS=10

TMS=8

Applied voltage/relay setting voltageApplied voltage/relay setting voltage

Ope

rati

ng ti

me

(sec

)O

pera

ting

tim

e (s

ec)

Undervoltage Characteristic

0.01

0.1

1

10

100

0 2 4 6 8 10 12 14 16 18 20

TMS=1

TMS=8TMS=10

TMS=5TMS=3

Applied voltage/relay setting voltageApplied voltage/relay setting voltage

Ope

rati

ng ti

me

(sec

)O

pera

ting

tim

e (s

ec)

Overvoltage Characteristic

142 mm

165

mm

Front

129 1 mm

139

1 m

m

Panel Cutout

198 mm

34 mm

136

mm

Side

Typical Application Diagrams

3

2

6

5

9

8

12

11

31

3233

13

14

343635

3837

4039

4241

2726

283029

25

24

22

23

ExternalDigital

Input

Uaux

R1

R2

R3

R4

R5

AB

C

Trip Contact

A

BCPhase rotation

InternalRelayFailure

Termination ResistorN-

P+CommunicationCable Shield

3

2

6

5

9

8

12

11

31

3233

13

14

343635

3837

4039

4241

2726

283029

25

24

22

23

ExternalDigital

Input

Uaux

R1

R2

R3

R4

R5

AB

C

Trip Contact

A

BCPhase rotation

InternalRelayFailure

Termination ResistorN-

P+CommunicationCable Shield

3

2

6

5

9

8

12

11

31

3233

13

14

343635

3837

4039

4241

2726

283029

25

24

22

23

ExternalDigital

Input

Uaux

R1

R2

R3

R4

R5

AB

C

Trip Contact

A

BCPhase rotation

InternalRelayFailure

Termination ResistorN-

P+CommunicationCable Shield

3

2

6

5

9

8

12

11

31

3233

13

14

343635

3837

4039

4241

2726

283029

25

24

22

23

ExternalDigital

Input

Uaux

R1

R2

R3

R4

R5

AB

C

Trip Contact

A

BCPhase rotation

InternalRelayFailure

Termination ResistorN-

P+CommunicationCable Shield

3Vp-p + Vresidual connection 2Vp-p + Vresidual connection

3Vp-n + Vresidual connection 3Vp-n connection

Ordering Information

MU2300-150D For 50 / 60 Hz system, auxiliary voltage 24 ~ 150 V DC

MU2300-240AD For 50 / 60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DC

MODEL DESCRIPTION

Case Dimensions

MU

2300

Page 49: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MU350

Technical Data

SETTING RANGESUndervoltage Time delay for undervoltage : 0.1s to 30sOvervoltage Time delay for overvoltage : 0.1s to 30sStart time delay : 0s to 999sUnbalance Time delay for unbalance : 0.5s to 30sPhase loss : Fixed time <0.5sPhase sequence : Fixed time <0.5s

AUXILIARY SUPPLYMU350-415V : 380 V (-25%) to 415 V (+20%) AC Supply frequency : 45 Hz to 65 HzMaximum power consumption: 3VA

MEASURING INPUTLine to line : 100 to 415 (+20%) VAC Line to Neutral : 58 to 240 (+20%) VAC

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORSAuxiliary supply : Green indicatorPickup indicator : Red indicatorTrip : 7-segment display and

red LED indicators

ACCURACYProtection thresholds : ± 3%Time delay : 0 to 0.5s, ± 15% with

minimum 40ms : 0.6s and above, < ± 3%Measurements : ± 3%

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.31 kg

Product Description

MU350 is 3-phase voltage relay that combines various protections and starting delay.

Features

• Undervoltage

• Overvoltage

• Delay-on

• 2 voltage-free output contacts

• Voltage and frequency display

• 3-Phase

• Unbalance

• Phase loss

• Phase sequence

• With or without neutral connection

• Phase to phase or phase to neutral monitoring

• Programmable relay outputs

• ANSI Code : 27, 47, 59, 60

Voltage Relay

MU

350

Page 50: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Ordering Information

MU350-415V 3-Phase, auxiliary voltage 380 ~ 415 V AC, 45-65 HzMODEL DESCRIPTION

Voltage Relay

Typical Application Diagrams

MU

350

L1 N

R2R1

L-L 100-415V AC, L-N 58-240V AC

L2 L3

L1L2L3N

AUX

380-415V AC

(OPTIONAL)

NC NO COM NC NO COM

Case Dimensions

96 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Panel Cutout

96 m

m

90 mm70 mm

Side

Page 51: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MU250MU150

Technical Data

SETTING RANGESUndervoltage : 1% to 25%Time delay for undervoltage : 0.1s to 30sOvervoltage : 1% to 20%Time delay for overvoltage : 0.1s to 30sStart time delay : 0s to 999s

For MU250 only:Unbalance : 3% to 20%Time delay for unbalance : 0.5s to 30sPhase loss : Fixed time <0.5sPhase sequence : Fixed time <0.5s

POWER SUPPLY INPUTInput voltage:MU150-110V & MU250-110V : 100 V (-25%) to 120 V (+20%) ACMU150-240V & MU250-220V : 220 V (-25%) to 240 V (+20%) ACMU250-415V : 380 V (-25%) to 415 V (+20%)Supply frequency : 45 Hz to 65 Hz

Maximum power consumption:MU250 : 3VAMU150 : 2.5VA

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORSAuxiliary supply : Green indicatorPickup indicator : Red indicatorTrip : 7-segment display and red

LED indicators

ACCURACYProtection thresholds : ± 3%Time delay : 0 to 0.5s, ± 15% with

minimum 40ms : 0.6s and above, < ± 3%Measurements : ± 3%

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICALMounting : DIN railDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.4 kg

Product Description

MU150 and MU250 are voltage relays that combine various protections and starting delay.

MU150 is used for single-phase monitoring while MU250 is used for 3-phase monitoring.

Features

• Microprocessor based numerical relay• Undervoltage• Overvoltage• Delay-on• 2 voltage-free output contacts• Voltage and frequency display• ANSI Code : 27, 47, 59, 60

Features For MU 250 only

• 3-Phase• Unbalance• Phase loss• Phase sequence• With or without neutral connection• Phase to phase or phase to neutral monitoring

MU 250

MU 150

Voltage Relay

MU

250 / 150

Page 52: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Ordering Information Case Dimensions

MU150-110V Single-Phase, 100/110/120 V AC, 45-65 Hz power supply

MU150-240V Single-Phase, 220/230/240 V AC, 45-65 Hz power supply

MU250-110V 3-phase, 100/110/120 V AC 45-65 Hz power supply

MU250-220V 3-phase, 220/230/240 V AC 45-65 Hz power supply

MU250-415V 3-Phase, 380/400/415 V AC, 45-65 Hz power supply

MODEL DESCRIPTION

Front

Side

71 mm

20 mm

45 mm

20 mm

70 mm

85 mm

30 mm 20 mm 20 mm

Voltage Relay

R2R1

62 3 4 5 71

8 9

COM NO NC COM NO NC

10 11 12 13 14

(OPTIONAL)

L1

L2

L3

N

MU250

(Neutral connection is optional)

Typical Application Diagrams

R2R1

62 3 4 5 71

8 9

COM NO NC COM NO NC

10 11 12 13 14

L

N

MU150

MU250 MU150

MU

250 / 150

Page 53: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MX210

Technical Data

POWER SUPPLY INPUT3-Phase SystemPhase-to-phase voltage : 380 V (-25%) to 415 V

(+20%) AC

Single Phase Phase-to-neutral voltage : 220 V (-25%) to 240 V

(+20%) ACFrequency range : 45 to 65 HzMax. power consumption : 3 VA maximum

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

SETTING RANGESUndervoltage : 78% - 98%Overvoltage : 102% - 122%Delay time : 0.1 - 10sNormal voltage : 380, 400, 415 Vpp, 220,

230, 240, Vpn3-phase / Single-phase

ACCURACY Protection thresholds : ± 3%Hysteresis : 1%Delay time : 0-0.5s, ± 15%,

40ms minimum : 0.5s and above, ± 3%Measurements : ± 3%

INDICATORSPower supply ON : Green indicatorOutput ON : Green indicatorUndervoltage : Red indicatorOvervoltage : Red indicatorPhase error : Red indicator

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICALMounting : DIN railDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.3 kg

Features

• Numerical voltage protection relay

• Undervoltage

• Overvoltage

• Phase loss

• Phase sequence

• 3-Phase/Single-phase

• ANSI Code: 27, 47, 59

Product Description

MX210 is voltage relay that combinesovervoltage, undervoltage, phase loss,phase sequence and delay start functions.

MX210 can be programmed by user toset nominal voltage as well as set into 3-phase or Single-phase mode.

3 - Phase Voltage R

elayM

X 210

Page 54: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

3 - Phase Voltage R

elay

Case Dimensions Ordering Information

Wiring Diagram

Operations Diagram

Single-Phase System

i ) Over Voltage Function

3-Phase System

ii ) Under Voltage Function

T

Over Voltage LimitHysteresis

RelayON

RYB

>U LED ON

T

Under Voltage Limit

Hysteresis

RelayON

<U LED ON

RYB

MX 210

1 2 3 4 5 6

8 9 10 11 12 13

7

14

R1

L

N

L1

L2

L3

N

1 2 3 4 5 6

8 9 10 11 12 13

7

14

R1

MX210 - 415V 3-Phase 380-415V AC Single-Phase 220-240V AC 45-65Hz

MODEL DESCRIPTION

Front Side

71 mm

20 mm

45 mm

20 mm

70 mm

85 mm

30 mm 20 mm 20 mm

Page 55: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MX200AMK180AMK160AMX 200A

Under & Over Voltage Relay

MX 180AOver Voltage Relay

MX 160AUnder Voltage Relay

Technical Data

POWER SUPPLY INPUT3-Phase SystemPhase-to-phase voltage : 380 V AC ± 20%

400 V AC ± 20% 415 V AC ± 20%

Single Phase Phase-to-neutral voltage : 220 V AC ± 20%

230 V AC ± 20% 240 V AC ± 20%

Frequency range : 45 to 65 HzMax. power consumption : 3 VA

Input ConnectionsFor 3-phase model : Phase L1, L2, L3 to

pin 5, 6, & 7 Neutral to pin 11For single-phase model : Phase L to pin 5, 6 &

7*** Neutral to pin 11

SETTING RANGESLower voltage limit * : 78% - 98%Upper voltage limit ** : 102% - 122%Delay time, T : 0.1 - 10s

HYSTERESIS ≤1% of rms - value

OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORSPower supply ON : Green indicatorOutput ON : Red indicatorUnder voltage limit (U<) * : Red indicatorOver voltage limit (U>) ** : Red indicator

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICALMounting : Circular 11-pin plug-in

socketDimension (mm) : 35(w) x 80(h) x 72.5(d)Approximate weight : 0.3 kg

* Applicable to MX160A and MX200A only

** Applicable to MX180A and MX200A only

*** For single phase connection, short pin 5,6 & 7

Features

• Electronic monitoring relay

• Voltage monitoring for single 3-phase system

• Phase failure monitoring

• Adjustable voltage limit

• Adjustable delay time

• Indicators for voltage fault

• Indicators for power and output ON

• ANSI Code : 27, 47, 59

Product Description

MX160A, MX180A & MX200A are single or 3-phase monitoring relays. The relays are designed for application where it required to maintain the voltage within set limits. A built-in adjustable time delay prevents nuisance tripping.

Voltage Relay

MX 200A

/ 180A / 160A

Page 56: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Voltage Relay

Case Dimensions Ordering Information

80 mm

72.5 mm

35 mm

MX160A - 380

MODEL

UnderVoltage

Monitoring

YES

MX160A - 400 YES

MX160A - 415 YES

OverVoltage

Monitoring

NO

NO

NO

SupplyVoltage

V AC

380

400

415

MX180A - 380 NO YES 380

MX180A - 400 NO YES 400

MX180A - 415 NO YES 415

MX200A - 380 YES YES 380

MX200A - 400 YES YES 400

MX200A - 415 YES YES 415

FUNCTION

Wiring Diagram

Operations Diagram

L3

L2

L1

N

5 6 78

9

10111

2

3

4

L

N

5 6 78

9

10111

2

3

4

Single-Phase System

i ) Over Voltage Function**

3-Phase System

ii ) Under Voltage Function*

T

Over Voltage LimitHysteresis

RelayON

RYB

>U LED ON

T

Under Voltage Limit

Hysteresis

RelayON

<U LED ON

RYB

MX 200A

/ 180A / 160A

Page 57: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MX100MK50MX 100

Phase Sequence &Phase Failure monitoring

MX 50Phase Failure monitoring

Technical Data

POWER SUPPLY INPUT

Phase-to-phase voltage : 230 V AC ±20% : 400 V AC ±20%Frequency range : 45 to 65 HzMax power consumption : 3 VAInput connections : Phase L1 to pin 5 Phase L2 to pin 6 Phase L3 to pin 7 Neutral (optional) to

pin 11

OUTPUT CONTACTS

Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORS

Power supply ON : Green indicatorOutput ON : Red indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Circular 11-pin plug-in socket

Dimension (mm) : 35(w) x 80(h) x 72.5(d)Approximate weight : 0.3 kg

Voltage Relay

MX 100 / 50

Features

• Electronic monitoring relay

• Phase sequence monitoring*

• Phase failure monitoring

• Plug-in type module

• Indicators for power and alarm status

• ANSI Code : 47

Product Description

This phase sequence and phase failure relay is designed for application where the 3-phase supply needs to be continuously monitored for proper sequencing and phase loss. Commonly used to protect a 3-phase motor.

Page 58: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Voltage Relay

MODEL

MX100 - 230

MX100 - 400

MX50 - 230

MX50 - 400

DESCRIPTION

Auxiliary voltage 184~276 V AC

Auxiliary voltage 320~480 V AC

Auxiliary voltage 184~276 V AC

Auxiliary voltage 320~480 V AC

Wiring Diagram

Function Table

Example 2

L3

L2

L1

N

5 6 78

9

10111

2

3

4

3 ~L3

Example 1

L2

L1

5 6 78

9

10111

2

3

4

3~

Condition

1

2

3

4

5

6

Pin 5

L1

Loss

L1

L1

L2

L3

Pin 6

L2

L2

Loss

L2

L1

L2

Pin 7

L3

L3

L3

Loss

L3

L1

Relay

ON

OFF

OFF

OFF

OFF

OFF

Remark

System healthy

Phase failure

Phase failure

Phase failure

Sequence fault*

Sequence fault** Applicable to MX100 model only

Case Dimensions Ordering Information

80 mm

72.5 mm

35 mm

MX 100 / 50

Page 59: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Technical Data

INPUT

Rated Phase-neutral voltage : 220V to 240V ACRated Phase-phase voltage : 380V to 415V ACRated frequency : 50 or 60 HzRated current (In) : 5ABurden : < 0.3 VA at InThermal withstand : 1.2 x Un , 2 x In continuous : 1.2 x Un , 10 x In for 3 secPower consumption : 3 VA maximum

OUTPUT CONTACTS

Rated voltage : 250 V AC/DCContact rating : 5 AExpected electrical life: 100,000 operations at

rated currentExpected mechanical life: 5 x 106 operations

SETTING RANGES

Range : 2% to 20% reverse current with 1% Hysteresis

Time delay : 0 sec to 20 sec3-Phase 4-wire (star) or 3-Phase 3-wire (delta)

ACCURACY

Protection thresholds Hysteresis : ± 3%Delay time : 1% : 0-0.5s, ± 15%, 40ms minimum.Measurements : 0.5s and above, ± 3% : ± 3%

INDICATORS

Auxiliary supply : Green indicatorDelay : Red indicatorTrip : Red indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing

MECHANICAL

Mounting : DIN railDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.3 kg

Reverse P

ower R

elayR

PR

415A

RPR415AFeatures

• Reverse power monitoring

• 3-phase, 3 or 4-wire system

• Adjustable reverse power setting

• Adjustable tripping time delay

• Indicators for auxiliary power, trip delay and trip status

• Test button

• ANSI Code: 32

Product Description

RPR 415A relay is a directionally controlled timing relay used to protect AC generators from motoring. When such condition occurs and the reverse current exceeded the customer adjustable preset limit for a predetermined delay time, the trip relay operates to disconnect the circuit.

Page 60: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Reverse P

ower R

elay

Case Dimensions

Ordering Information

RPR415A 380-415Vpp AC / 220-240Vpn AC, 45-65Hz

3-Phase 4-wire / single-phase system 3-Phase 3-wire system

MODEL DESCRIPTION

Typical Application Diagram

RP

R 415A

Front Side

71 mm

20 mm

45 mm

20 mm

70 mm

85 mm

30 mm 20 mm 20 mm

L1

L2

L3

N

1 2 3 4 5 6

8 9 10 11 12 13

7

14

R1

S1 Generator3~

I

S1S2

L1

L2

L3

1 2 3 4 5 6

8 9 10 11 12 13

7

14

R1

S1 Generator3~

I

S1S2

415V

240V

Page 61: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Technical Data

INPUT

Rated voltage (Un) : 380 ~ 440 V ACRated current (In) : 5 ARated frequency : 50 or 60 HzOverload : 1.2 x Un , 2 x In continuous 1.2 x Un , 10 x In for 3 sec

OUTPUT CONTACTS

Rated voltage : 250 V AC/DCContact rating : 5 AExpected electrical life: 100,000 operations at

rated currentExpected mechanical life: 5 x 106 operations

SETTING RANGES

Range : 2% to 20% reverse current with 1% Hysteresis

Time delay : 0 sec to 20 sec

INDICATORS

Auxiliary supply : Green indicatorDelay : Red indicatorTrip : Red indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 142(d)Approximate weight : 0.8 kg

Reverse P

ower R

elayR

PR

415

RPR415Features

• Reverse power monitoring

• 3-phase-4-wire system

• Adjustable reverse power setting

• Adjustable tripping time delay

• Indicators for auxiliary power, trip delay and trip status

• Test button

• ANSI Code : 32

Product Description

The RPR 415 relay is a directionally controlled timing relay used to protect AC generators from motoring. When such a condition occurs and the reverse current exceeded the customer adjustable preset limit and the current persists for a predetermined delay time, the trip relay operates to diconnect the circuit.

Page 62: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Reverse P

ower R

elay

Case Dimensions

142 mm

132 mm

Side

96 m

m

96 mm

Front

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Panel Cutout

Ordering Information

RPR415 Auxiliary voltage 380 ~ 440 V AC

MODEL DESCRIPTION

2 3 4 5 6 7 8

9 10 11 12 13 14 15

1

16

NC

P1

S1

COM

DIRECTION OF CURRENT FOR OPERATION

NO

L1

L2

L3

N

Typical Application Diagram

RP

R 415

Page 63: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Pow

er Factor Regulator

PFR

140 / 120 / 80 / 60

Technical Data

RATINGS AUXILIARY POWER SUPPLY

Current Supply voltage : 220~240 V AC / 380~415 V AC

Operating Limits : -15% + 10%Consumption : 10 VA maxRated frequency : 50 Hz or 60 Hz

OUTPUT CONTACTS

Numbers of outputs : 6 / 8 / 12 / 14 ( PFR60 / PFR80 / PFR120 / PFR140 )

Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operationsMax current for the common terminals : 12 A continuous

CURRENT INPUT

Rated current ( In ) : 5 AOperating Limits : 0.05 A to 6.5 ARated Frequency : 50 Hz or 60 Hz

CONTROL RANGE

Power factor setting : 0.8 Ind - 0.8 CapC/K setting : 0.03 - 1.20 / AutomaticSwitching sensitivity : 5 - 600 s/stepReconnection time for same step : 5 - 240 sTHD threshold : 0.20 - 3.00 ( 20% - 300% ) /

OFFSwitching Program : Automatic / Automatic

Rotate / 4-quadrant / Manual

: 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 12 / 16

( Automatic if C/K set to Auto )

PFR140PFR120PFR80PFR60

Features

• Microprocessor based intelligent auto switching control

• Automatic C/K and rated step adjustment

• Automatic CT polarity correction

• Display of power factor, current & total harmonic distortion of current

• Programmable sensitivity

• Last step can be used as alarm/fan output

• Under/over voltage alarm, under/over compensate alarm & high harmonic distortion alarm

• User-friendly setting

• Complies with IEC 61000-6-2 standard

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 144(w) x 144(h) x 90(d)Enclosure protection : IP54 at the panelApproximate weight : 1.2 kg

Page 64: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

MAIN

P1

P2

FUSE

K14 K13 K2 K1

24232221201918171615

14

13

12111098

14131211

7654321

10987654321

AUXVOLTAGE

CURRENT/ 5 A

Po

we

r F

act

or

Re

gu

lato

r

L1L2L3N

380~415 V AC

1615

14

13 AUXVOLTAGE

For 220~240 V AC Model Only

220~240 V AC

LOAD

Typical Application Diagram

Case Dimensions Ordering Information

144 mm

138 mm

138

mm

76 mm90 mm

144

mm

Front

Side

PanelCutout

MODEL

PFR60 - 415 - 50

PFR80 - 415 - 50

PFR120 - 415 - 50

PFR140 - 415 - 50

PFR60 - 220 - 50

PFR80 - 220 - 50

PFR120 - 220 - 50

PFR140 - 220 - 50

PFR60 - 415 - 60

PFR80 - 415 - 60

PFR120 - 415 - 60

PFR140 - 415 - 60

PFR60 - 220 - 60

PFR80 - 220 - 60

PFR120 - 220 - 60

PFR140 - 220 - 60

DESCRIPTION

6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC

6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC

6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC

6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC

Pow

er Factor Regulator

PFR

140 / 120 / 80 / 60

Page 65: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Technical Data

RATINGS AUXILIARY POWER SUPPLY

Model PFR96 : 110 ~ 120 V AC / 220 ~ 240 V ACModel PFR96P : 380 ~ 415 V ACOperating Limits : -15% + 10%Consumption : 10 VA maxRated frequency : 50 Hz or 60 Hz

OUTPUT CONTACTS

Numbers of outputs : 6Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operationsMax current for the common terminals : 12 A continuous

CURRENT INPUT

Rated current ( In ) : 5 AOperating Limits : 0.15 A to 6.5 ARated frequency : 50 Hz or 60 Hz

CONTROL RANGE

Power factor setting : 0.8 Ind - 0.8 CapC/K setting : 0.03 - 1.20 / AutomaticSwitching sensitivity : 5 - 600 s/stepReconnection time for same step : 5 - 240 sSwitching Program : Automatic / Automatic

Rotate / 4-quadrant / Manual

: 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 12 / 16

( Automatic if C/K set to Auto )

PFR96PFR96P

Features

• Microprocessor based intelligent auto switching control

• Automatic C/K and rated step adjustment

• Automatic CT polarity correction

• Display of power factor & current

• Programmable sensitivity

• Last step can be used as alarm/fan output

• Under/over voltage alarm, under/over compensate alarm

• User-friendly setting

• Complies with IEC 61000-6-2 standard

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg

For PFR 96

• For single-phase system

For PFR 96P

• For 3-phase system

Pow

er Factor Regulator

PFR

96 / 96P

Page 66: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

K1 K6K5

FUSE

Po

we

r F

act

or

Re

gu

lato

r

VOLTAGE380~415V AC

MAIN

L1L2L3N

8

7

6

5

4

3

2

1

CURRENT/ 5 A

6

5

4

3

2

1

16

15

14

13

12

11

10

9P2

P1

FUSE

LOAD

K1 K6K5

FUSE

FUSE

Po

we

r F

act

or

Re

gu

lato

rVOLTAGE220 V AC /110 V AC

MAIN

L1L2L3N

8

7

6

5

4

3

2

1

CURRENT/ 5 A

6

5

4

3

2

1

16

15

14

13

12

11

10

9P2

P1

LOAD

Typical Application Diagram

Ordering Information

Diagram 2 - For model PFR96PDiagram 1 - For model PFR96

Case Dimensions

96 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

70 mm90 mm

96m

m

Front

Side

PanelCutout

MODEL

PFR96 - 220 - 50

PFR96 - 220 - 60

PFR96 - 110 - 50

PFR96 - 110 - 60

PFR96P - 415 - 50

PFR96P - 415 - 60

DESCRIPTION

6 Steps, for 50 Hz system, auxiliary voltage 220~240 V AC

6 Steps, for 60 Hz system, auxiliary voltage 220~240 V AC

6 Steps, for 50 Hz system, auxiliary voltage 110~120 V AC

6 Steps, for 60 Hz system, auxiliary voltage 110~120 V AC

6 Steps, for 50 Hz system, auxiliary voltage 380~415 V AC

6 Steps, for 60 Hz system, auxiliary voltage 380~415 V ACP

ower Factor R

egulatorP

FR 96 / 96P

Page 67: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Typical Application Diagram

Pow

er Factor Regulator

PFR

LCD

PFRLCDFeatures

• 2” inch, 64 x 128 dot matrix LCD display with back lighting

• Three phase and single phase detection of reactive power

• 12 (or 8 for 8 step model) output with two additional

• Independent contact for signal alarm output and fan output

• Three phase compensation mode

• • Automatic detection of C/K and rated

step value

• No Voltage release

• • Alarm linked signal contact

• Programmable fan control

• ModBus-RTU communication

• Active, reactive, apparent power

• Temperature

• Phase voltage and phase current

• Frequency

• Up till 31st order Harmonics measurement in graphical and table format

• Power Factor and Displacement Power Factor (Cosφ)

Measurement Parameters

L1 L2 NL3

3435

3344

3243

4241

3938

3736

40

2120

2214

2313

1211

98

76

104

32

15

SIGFAN

12

45

67

39

1011

128

2430 Thermistor

T1

P+

N-RP

T2

31

GND

PFR

LC

D

FANSIG

AUX

NL

S2S2

S1S1

S2S1

L3L2

L1N

CT2

CT1

CT3

RS485 Modbus-RTU

FUSE

FUSE

P1P2

P1P2 P1

P2

K12 K2 K1

PFRLCD120P3-230-50

LOAD

L1 L2 NL3

3435

3344

3243

4241

3938

3736

40

2120

2214

2313

1211

98

76

104

32

15

SIGFAN

12

45

67

39

1011

128

2430 Thermistor

T1

P+

N-RP

T2

31

GND

PFR

LC

D

FANSIG

AUX

NL

Out

InL3

L2L1

NC

T1

RS485 Modbus-RTU

FUSE

FUSE

P1P2

K12 K2 K1

PFRLCD120P1-230-50

LOAD

PFRLCD Connection diagram for 3 Phase 12 Step model PFRLCD Connection diagram for 1 Phase 12 Step model

Page 68: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Ordering Information

Case Dimensions

Front View

Panel Cutout

144mm

Side View

122mm

102mm

144m

m

138mm

138mm

Pow

er Factor Regulator

Technical Data

CURRENT INPUT (EACH PHASE)

Nominal Current : 5 A rmsOperating Limits : 0.01-10 A rmsRated frequency : 50 Hz or 60 Hz

VOLTAGE INPUT

(EACH PHASE with respect to neutral)

Nominal Voltage : 230 VrmsOperating Limits : 0 - 277 V L-NConsumption : 0.05 VARated Frequency : 50 Hz or 60 HzCatagory : III

THERMISTOR INPUT

Thermistor Temperature range : 0 – 100 °C

AUXILIARY

Auxiliary Input Voltage Range : 85 - 265 VrmsConsumption : 10 VA maxRated Frequency : 50 Hz or 60 Hz

OUTPUT CONTACTS

Number of outputs : 14 (model dependent)Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

CONTROL RANGE

Target Power factor : 0.80 Inductive – 0.80 Capacitive

C/K setting : 0.03 – 1.20 / Automatic detect

Sensitivity : 5 - 300s / StepReconnection time : 5 – 240s Switching program : Automatic/ Manual/

Four-quadrant/ Rotational/ Linear

: 0/ 1/ 2/ 3/ 4/ 5/ 6/ 8/ 12/ 16/ Fixed

Detection mode : L1 / L2 / L3 / Max Load / Three Phase

Fan Setting : Fixed on / Output On / Temperature / None

Signal Contact programmable alarm / None

ALARM SETTING RANGE

%THDI : 20 - 300% / OFFOver Voltage : 253 – 264 V/ OFFUnder Voltage : 195 – 204 V/ OFFOver Current : 5.50 – 7.00 A/ OFFUnder Current : 0.01 – 0.15 A/ OFFUnder Compensate : On / OFFOver Compensate : On / OFF*CT Polarity Error : On / OFFStep Error : On / OFFTemperature : 36 – 70 °C / OFF

DISPLAY

%THDI & %THDV : 0 – 500%Harmonics Resolution : Up till 31st Harmonics Active power : 0– 3000 WReactive power : 0 – 3000 VARApparent power : 0 – 3000 VAVoltage : 0 – 300 VACCurrent : 0.00 – 10.0 A rmsTemperature : 0 – 100 °CFrequency : 45 – 65HzPower Factor : -1.00 – 1.00Displacement Power Factor : -1.00 – 1.00

ENVIRONMENT CONDITIONS

Temperature : -5°C to +55°CHumidity : 56 days at 93%RH and

40°C non-condensingPollution Degree : IIDielectric Withstand : IEC61010-1Altitude : 2000 m

ELECTROMAGNETIC COMPATIBILITY (EMC)

Part 6-2: Generic standards : IEC61000-6-2Immunity for industrial environmentsPart 6-4: Generic standards : IEC61000-6-4Emission standard for industrial environments

MECHANICAL Mounting : Panel mountingDimension (mm) : 144(w) x 144(h) x 122(d)Enclosure protection : IP54 at the panel IP20 at the bodyApproximate weight : 1.2 kg (for three phase model), 1 kg (for single phase model)

MODEL

PFRLCD120P3-230-50

PFRLCD80P3-230-50

PFRLCD120P1-230-50

PFRLCD80P1-230-50

PFRLCD120P3-230-60

PFRLCD80P3-230-60

PFRLCD120P1-230-60

PFRLCD80P1-230-60

DESCRIPTION

12 Step, 3 Phase, 230Vrms, 50Hz Model

8 Step, 3 Phase, 230Vrms, 50Hz Model

12 Step, 1 Phase, 230Vrms, 50Hz Model

8 Step, 1 Phase, 230Vrms, 50Hz Model

12 Step, 3 Phase, 230Vrms, 60Hz Model

8 Step, 3 Phase, 230Vrms, 60Hz Model

12 Step, 1 Phase, 230Vrms, 60Hz Model

8 Step, 1 Phase, 230Vrms, 60Hz Model

PFR

LCD

Page 69: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Tests And StandardsElectrostatic discharge IEC61000-4-2, Class III, air discharge 8 KVElectrostatic discharge IEC61000-4-2, Class III, contact discharge 6 KVElectrical fast transient IEC61000-4-4 4 KV, 5/50nsSurge immunity IEC61000-4-5 4 KV, L to EEnclosure protection when panel mounted Front: IP41 Enclosure: IP30

AN112AN120AN128

Annunciator

AN

112 / 120 / 128

Features

• 12, 20 or 28 windows. Replaceable super-bright LED modules, with choice of amber or red illumination

• 11 Alarm Sequences as per ISA-18.1 standard

• programmable, either from front panel built-in pushbutton or using PC

• Option of either RS232 or RS485 MODBUS-RTU communication. Comes with user-friendly

• Repeat relay for each window as well as

relays for connection to external equipment to form alarm management system

• Sleep or unattended mode feature is available, for stations not permanently manned

• Auto-silence and auto-acknowledge features, with delay settable from 1 – 255 s

• Other amount of windows available upon request.

The AN112/120 series Alarm Annunciator provides ideal solution for all your alarm system management and requirement. It comes with either 12, 20 or 28 windows, and due to the use of microprocessor-based design, the alarm annunciator is highly

and industries.

Programmable Alarm Annunciator

Technical Data

WINDOWWindow Dimension : 50 x 30 mm.Type: White translucent lens.Colours: Red, Amber. Coloured

module.Windows Flash Fast: 1.4 Hz

Slow: 0.45 Hz

Intermittent:

ALARM SEQUENCESM, A, R, R-12, F1A, F1M, F2A, F2M, F3A, F3M, Follower

AUXILIARY POWER INPUTFuse protected.AN1xx-30 : 24-36 V DC or 18-27 V AC.AN1xx-110 : 88-132 V DC or 64-95 V AC.Power consumption : AN112: 6 W, AN120: 8 W,

AN128: 10W

ALARM CONTACT INPUTSOpto-isolated inputsAN1xx-30 : 24-36 V DCAN1xx-110 : 88-132 V DCInput current : 3 mA typical

OUTPUT CONTACTSRepeat relays : Potential free for each

alarm point. 5 A at 250 V AC, 3 A at 30 V

DC. Resistive load.AUX1-AUX3, RBACK, SSP : 5 A at 250 V AC, 5 A at 30 V

DC. Resistive load.

TERMINALSWire size : 28-14 AWG. ( 0.08mm2 to 2.5mm2 ) Removable screw type terminal block

COMMUNICATION Hardware interface : AN1xx - xx - x - A: RS232 AN1xx - xx - x - B : Isolated

RS485Protocol : Modbus - RTUBaud rate : 300 to 57600

ENVIRONMENT CONDITIONSOperation temperature: -20 to 60˚CStorage temperature : -20 to 80˚CHumidity : 0 - 95% RH,

non condensing

MECHANICAL Mounting : Panel MountingApproximate weight : AN 112 : 2.4 kg AN 120 : 3.1 kg AN 128 : 3.5 kg

Page 70: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Annunciator

Case Dimensions

Ordering Information

Order code:A: RS 232 communicationB: RS 485 communication

0: without repeat relays1: with repeat relays

Power Supply: 30, 110 V DCNumber of Windows: 12, 20, 28

For example: 12 windows, 30 V DC, with repeat relays, RS232 communication: AN112-30-1-A

AN1 - - -

Typical Connection Diagram

4 3 2 1C12

- +-+

- +

4 3 2 1C11

- +

4 3 2 1C10

- +

4 3 2 1

1 21Sleep

2 3

1 2

Power

PowerGround

3 5 6 7

D-D+

4

C9

RS485

RS232

- +

4 3 2 1C8

- +

4 3 2 1C7

- +

4 3 2 1C6

- +

4 3 2 1C5

- +

4 3 2 1C4

- +

-+

1 2 3 4 2 3 41

RBCK SSP AUX3

Relay output

AUX2 AUX1

6 7 85 109

Button

MuteAck

ResetTest

1RstDis

1 2 3 4C3

-+

1 2 3 4C2

-+

1 2 3 4C1

AN120 Front

237 mm

217

mm

AN112 Front

237 mm

157

mm

Bottom

206 mm

1.5 mm

132

mm

132 mm

126 mm

AN112 Side

132 mm

186 mm

AN120 Side

AN128 Front

237 mm

277

mm

132 mm

246 mm

AN128 Side

AN

112 / 120 / 128

Page 71: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Features

• Alarm monitoring

• Outputs for lamp and horn

• Indicators for output contacts

Product Description

Alarm relay provides LED indication and output

contact signalling when there is alarm signal

received. The alarm relay consist of alarm input,

alarm accept, alarm reset, lamp test controlled

input and 2 relay contacts. Red LED indication

2 (LED) turned on when alarm signal is received.

AL24

Annunciator

AL 24

Technical Data

INPUT

Auxiliary input : 24 V DC ± 5%Max power consumption : 2 W

INPUT CONNECTION

Alarm input : Pin 7Aalrm accept : Pin 4Lamp test : Pin 8Reset : Pin 5Common : Pin 6

INPUT TYPE

Dry contact

OUTPUT CONTACTS

Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

INDICATORS

Auxiliary supply : Green indicatorRelay 1 (Lamp) : Red indicatorRelay 2 (Horn) : Red indicator

ENVIRONMENTAL CONDITIONS

Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and

40˚C non-condensing

MECHANICAL

Mounting : Circular 11-pin plug-in socket

Dimension (mm) : 35(w) x 80(h) x 72.5(d)Approximate weight : 0.2 kg

Page 72: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Annunciator

Case Dimensions

80 mm

AUXILIARY

Alarm Relay

AL 24

RELAY 1RELAY 2

72.5 mm

35 mm

Ordering Information

AL 24 Auxiliary voltage 24 V DC

MODEL DESCRIPTION

Auxiliary supply (pin +2, -10)Alarm (pin 7, 6)Alarm accept (pin 4, 6)Reset (pin 5, 6)Relay 1 (Lamp)Relay 2 (Horn)Lamp test (pin 8, 6)

Operation Diagram

Connection Diagram

5 6 78

RY1

RESE

T

ALA

RMAC

CEPT

LAM

PTE

ST

NO

+

NO

COM

Power Supply ( DC only )

COM

RY29

10111

2

3

4

-

ALA

RM

AL 24

Page 73: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Technical Data

CT RATINGSRated current : 2-10ARated frequency : 50 Hz or 60 HzBurden : <0.3 VA at rated currentThermal withstand : Continuous : 2x max rated 45s : 6x max rated 1s : 10x max rated

BINARY INPUTRated input voltage : 12V (Supplied internally)

AUXILIARY SUPPLYModel MPR 500-240AD : 85 ~ 265 V AC 110 ~ 370 V DCSupply frequency : 50 or 60 HzMaximum power consumption : 3 VA typical

OUTPUT CONTACTSRated voltage : 250V ACContact rating : 5 AExpected electrical life : 100,000 operations at

rated currentExpected mechanical life : 5 x 106 operations

SETTING RANGESThermal Overloadtime constant, t6X : 1 – 40s. Step 0.1s for 1-10s, step 1s for 10-40s. Short circuit, I>> : B. Step 1 x IBShort circuit delay time, t>> : 0 – 25s. Step 0.1s for 1-10s, step 1s for 10-25s. Undercurrent, I<< : B. Step 1%Undercurrent delay time, t<< : 0 – 60s. Step 0.1s for 1-10s, step 1s for 10-60s.Unbalance, : Step 1%Unbalance delay time, t : 0 – 25s. Step 0.1s for 1-10s, Step 1s for 10-25s.Earth fault, I0 : B. Step 1%Earth fault delay time, t0 : 0 – 25s. Step 0.1s for 1-10s, step 1s for 10-25s.Phass loss : < 120msPhase sequence : < 120ms

Prolonged starting/stalled rotor, IS : B. Step 0.1 x IBProlonged starting time delay, tStart : 0 – 60s. Step 0.1s for 1-10s, step 1s for 10-60s.Stalled rotor delay time, tStall : 0 – 60s. Step 0.1s for 1-10s, step 1s for 10-60s.

INDICATORSRun : Green indicatorTrip/Pickup : 7-segment display and red indicatorThermal : Yellow indicator

ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C

non-condensing

MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Approximate weight : 0.8 kg

Motor P

rotection Relay

MP

R 500

MPR500Features

• Microprocessor based numerical relay

• Thermal overload

• Overcurrent

• Undercurrent

• Unbalance

• Phase loss

• Phase sequence

• Earth fault

• Prolonged starting/stall rotor

• 2 voltage-free output contacts

• ANSI Code : 37, 46, 47, 49, 50P, 50G

Page 74: MK 1000A MK 233A MK 203A MK 204A - Mikro Sdn Bhd · MK 1000A MK 233A MK 234A MK 203A MK 204A MK 231A MK 232A ... Overcurrent Relay Earth Fault Relay ... Mikro® reserves the …

Motor P

rotection Relay

(a) With 0% thermal capacity (cold start)

time

t6x

I / I B

10 sec

1 sec

2 sec3 sec

5 sec

21 3 4 5 6

20 sec30 sec40 sec1 min

2 min3 min

5 min

10 min

20 min30 min

1 hour

2 hour

2s

5s

10s

20s30s40s

1s1.05

Typical Application Diagrams

t6x

2s

5s

10s

20s30s40s

1s

(b) With prior 50% thermal capacity

21 3 4 5 6

1.05

I / I B

time

10 sec

1 sec

2 sec3 sec

5 sec

20 sec30 sec40 sec1 min

2 min3 min

5 min

10 min

20 min30 min

1 hour

2 hour

Thermal Tripping Curve Case Dimensions

Aux

6

2

3

4

5

L

R1

R2

N

9

10

11

12

13

14

715

816

1

MPR 500

L

M

K1

N

K1H1

S2

S1

K1

Block R1/Reset/Trip

Start

Stop

NO

NC

COM

COM

NC

NOBinaryinput

F1

F2

Single-Phase Motor)

Ordering Information

MPR500-240AD For 50 / 60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110 ~ 370 V DCMODEL DESCRIPTION

96 mm

110 mm100 mm

91.0 ± 0.5 mm

91.0

± 0

.5 m

m

Front

Side

Panel Cutout

96 m

m

MP

R 500

Aux

6

2

3

4

5

L

R1

R2

N

9

10

11

12

13

14

715

816

1

MPR 500

L1L2L3

M

K1

N

K1H1

S2

S1

K1

Block R1/Reset/Trip

Start

Stop

NO

NC

COM

COM

NC

NOBinaryinput

F1 F2 F3

F4

Motor with higher full load current using external CT