4
Monitoring Products contribute to improved safety Helix Challenge Test - NEW Daily Control DCG2 Test Pack - NEW Seal Control Sheet - NEW Chemical Indicator Strips Sterilization Tapes

Monitoring Products contribute to improved safety - Wipak · Monitoring Products contribute to improved safety Helix Challenge Test - NEW Daily Control DCG2 Test Pack - NEW ... •

  • Upload
    lethien

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Monitoring Products contribute to improved safety - Wipak · Monitoring Products contribute to improved safety Helix Challenge Test - NEW Daily Control DCG2 Test Pack - NEW ... •

Monitoring Productscontribute to improved safety

Helix Challenge Test - NEW

Daily Control DCG2 Test Pack - NEW

Seal Control Sheet - NEW

Chemical Indicator Strips

Sterilization Tapes

Page 2: Monitoring Products contribute to improved safety - Wipak · Monitoring Products contribute to improved safety Helix Challenge Test - NEW Daily Control DCG2 Test Pack - NEW ... •

2

4

1

3

134°C - 3,5 MIN. / 121°C - 15 MIN.

STEAM DARK=

Tips for use

Make sure the test is carried out correctly in each process.

• Complies with EN 867-5 and ISO 11140 (under preparation).• An ideal process challenge device (PCD) to simulate a “worst case” -scenario in the autoclave.• Suitable for all sterilization processes in a loaded autoclave for 3.5 minutes at 134 ˚C or for 15 minutes at 121 ˚C.• Can be used to test for maximum steam penetration where hollow instruments or instruments with small lumina are involved.

Helix Test System is designed to be used as a charge control and as a steam penetration test for hollow instruments with small lumina.

Unexposed

After correct exposure

134°C - 3,5 MIN. / 12 1°C - 15 MIN. STEAM

DARK=

134°C - 3,5 MIN. / 12 1°C - 15 MIN. STEAM DARK=

The Helix Challenge indicator strips are

• in compliance with EN – ISO 11140-1 (Class 6)• each marked with article number, lot number, time and temperature• made as adhesive stickers for easy attachment to fi les• easy to read with a clearly contrasting colour change from light green to dark

Operational qualifi cation of a sealing process required by ISO standard.

The sterilization package has to be sealed against ingress of micro-organisms - and this sealing needs to be a validated process. It is the responsibility of the packer.

The new standard ISO 11607: 2006 lays down the technical requirements for sterile barrier materials and their performance in its Part 1. It also stipulates the responsibilities of the user of the packaging in Part 2.

Steriking® Seal Control Sheet

Exclusively designed and patented by Wipak.

Steriking® Helix Challenge Test

Twist open the HX tube cap.

Fold the indicator strip at the line, so that the indicators are on the inside.

The different lengths after folding facilitate its removal after the test.

Place the strip with the folded end fi rst into the cap.

Close the cap tightly.

When it has cooled down after processing, open the cap and take out the strip for reading.

Page 3: Monitoring Products contribute to improved safety - Wipak · Monitoring Products contribute to improved safety Helix Challenge Test - NEW Daily Control DCG2 Test Pack - NEW ... •

Steriking® Daily Control DCG2 Test PackDaily Control DCG2 Test PackDaily Control DCG2 Test Pack

A new generation test for steam penetration and air leak detection

• A Bowie & Dick type routine test for pre- vacuum autoclaves in accordance with EN 285.• A new design in compact size sealed into a special grade paper bag.• Conforming to ISO 11140-1 (Class 2+6), ISO 11140-4, EN 867-4.

The test sheet in the pack

• Plastic-laminated to prevent any ink particles from migrating.• Printed with a Class 6 indicator with 100% heavy-metal-free ink.• Clear color change from light green to a dark color. An uniform dark color, either dark green or black, over the whole sheet confi rms that steam has penetrated effectively through to the centre of the sterilization pack.

Tips for use

Prior to performing the test, run a 134 °C cycle with the chamber empty. Immediately after this cycle place the Daily Control DCG2 in the chamber as closely as possible to the position which during validation is identifi ed as the cold spot. Carry out a steam penetration test (134 °C, max. 3.5 min.) in an otherwise empty chamber. Upon completion of the

DAILY CONTROL G2 134°C / 3.5 MIN.S T E R I K I N G ®

WIPAK MEDICA L

Maximum after correct exposure

Maximum uniform colour change that can be achieved.

Maximum uniform colour

DAILY CONTROL G2 134°C / 3.5 MIN.S T E R I K I N G ®

WIPAK MEDICA L

Silk-screen printing technology on the indicator sheet and an automated pack converting process together with a controlled production environment guarantee high quality and relia-ble performance. The DCG2 test is fully repro-ducible and the test sheet keeps its shape during the test process. The test pack is made of environment-friendlyunbleached fi lter paper. The outer pack is printed with a Class 2 process indicator.

The endpoint reaction is permanent, making it a reliable record when kept on fi le.

cycle remove the Daily Control DCG2 from the steri-lizer, open it and take out the indicator sheet.

The sheet must have changed from light green to a uniform dark colour. If any difference in this colour is noted, repeat the test. If this second test also fails, it should be recorded as a fail on the test sheet.

Record the results on the test sheet with other rele-vant data. If the test fails, the sterilizer is not func-tioning properly and needs maintenance, adjust-ment and/or subsequent validation. The endpoint reaction is permanent, making the sheet a reliable record when kept on fi le.

Tips for use

1. Set the temperature of the sealer unit to 155-180 °C (311-358 °F) in accordance with the manufacturer’s recommendation.

2. Run the upper part of the Seal Control sheet through the sealer and seal the fi lm to the paper back.

3. Check the quality of this test seal: the sealed lines should be continuous darker green with no white areas.

4. Fill in the form preprinted on the paper back of the Seal Control sheet, sign and fi le the document.

DAILY CONTROL G2 134°C / 3.5 MIN.S T E R I K I N G ®

WIPAK MEDICA L

Unexposed

A practical documentation system for daily heat-sealer validation and seal quality testing.

Not correctly exposed

Possible causes: sterili-zation time too short or temperature too low.

Possible causes: sterili-

DAILY CONTROL G2 134°C / 3.5 MIN.S T E R I K I N G ®

WIPAK MEDICA L

Minimum after correct exposure

Minimum uniform colour change that must be achieved.

Page 4: Monitoring Products contribute to improved safety - Wipak · Monitoring Products contribute to improved safety Helix Challenge Test - NEW Daily Control DCG2 Test Pack - NEW ... •

HC

P3_

IND

ICAT

OR

S_E

N_1

108_

Sek

tori.

net_

Mar

kprin

t

We

rese

rve

the

right

to

mak

e ch

ange

s in

the

pro

duc

ts.

Gas Plasma Tape Strips ITP

STEAM Strips AC250

Double STEAM Strips AC250/500

Gas Plasma Strips

Double FORMALDEHYDE Strips FO250/500

EO GAS Strips EO250

The Steriking® chemical indicator strips are designed for monitoring process conditions in each sterilization cycle. All indicators are corresponding to critical parameters in the sterilization cycle.

Steriking® indicator tapes ensure tight and safe closure of sterilization packages.

Steriking® Chemical Indicator Strips

Steriking® Sterilization Tapes

• Developed for a daily routine Bowie & Dick test• Pre-assembled from approved fi lter materials with an indicator sheet• Indicator provides a clear, permanent colour change from white to black• Easy to use

The DC test pack offers additional diagnostic features.

Effective sterilization by dry saturated steam depends on integrated temperature and time control and on the removal of air from the chamber and load.

The Bowie & Dick test is a routine perform-ance test for steam sterilizers for wrapped goods. A succesful Bowie & Dick test indicates rapid and uniform penetration of steam into the test pack.

Single-service test for steam penetration, steam quality and air leak detection.

Steriking® Daily Control DC20 Test Pack

Steam Tapes ITS

Masking Tapes ITN

Dry Heat Tapes ITH

Gas Tapes ITE

After sterilizationUnexposed

www.steriking.info E-Mail: [email protected]