15

Neri - Archilede S

  • Upload
    -

  • View
    240

  • Download
    0

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Neri - Archilede S
Page 2: Neri - Archilede S

Dec

or

ativ

e

com

for

t

per

for

ma

nce

We have to make the most of technology to achieve a more sustainable lifestyle, not just from an economic point of view but also in terms of the psychological aspect of safety and social relationships. it’s not simply and only about lighting, because even lamp posts contribute in some way to increasing the quality of life. Makio Hasuike

Page 3: Neri - Archilede S

285

170

700

870

350

2 Neri · Archilede Special

archileDe Special Scale 1:50Measures in mm

Archilede Special incorporates design,

performance and energy savings in a single

system of street lighting. Designed by

Makio Hasuike, Archilede Special is the

result of a collaboration between Neri SpA

and Enel Sole.

materials Made of cast aluminium, with a IP66

protection rating, the screen is made of

tempered extra-clear glass, 4mm thick,

IK09 mechanical resistance.

finishes Powder coated color RAL 9007.

Page 4: Neri - Archilede S

applications Roadway and street lighting, parking lots, roundabout lighting, pedestrian and bicycle paths

performance Latest LED/lens technology, energy savings (DALI), thermal dissipation

maintenance Easy installation and parts replacement

Page 5: Neri - Archilede S

6 Neri · Archilede Special

roadway and street lightingAnti-glare reflector, maximum brightness

uniformity on the ground.

parking lotsLight and safety optimisation: large areas

covered in a functional and efficient way.

roundabout lightingThe roundabouts optic distributes light

on the circulation ring without glaring.

pedestrian and bicycle pathsLight is concentrated only where needed,

ensuring effective lighting in harmony

with the urban context.

applicationS

Page 6: Neri - Archilede S

8 Neri · Archilede Special

LED Cree XP-G2

The wide emission surface and the

perimeter reflector increase the emission

efficiency maintaining reduced glare

values (see planning at value ti (%) p.21).

Archilede Special houses the latest

generation of LED Cree XP-G2 with

high-performance lighting efficiency

and a ceramic base guaranteeing

high thermal conductivity and electric

insulation to ensure a longer duration

in time.

The optical system is composed by

overlapping PMMA lenses with constant

high light transmission performance;

the multilayer system optimises the

quality of light even when the system

performances change.

performanceS: leD technoloGY

Reduced glare thanks to the wide emission surface. Latest generation LED Cree XP-G2 and PMMA multilayer lenses provide high and constant performance over time, even in case of failure of a single source.

Page 7: Neri - Archilede S

1110 Neri · Archilede Special neri.biz

Thanks to electronic ballasts equipped

with intelligent systems the lighting

management guarantees high energy

savings. The driver chosen for Archilede

Special can be equipped with the

features below:

ncl (neri constant lumen)Keeping flows consistentThe driver allows the initial flow to be kept

consistent throughout the product life cycle

by calibrating the current supply of the

LEDs and ensuring the same luminous flux

over time.

nvl (neri variable lighting)Stand-alone settingThe driver is equipped with a stand-alone

control that automatically adjusts the

light flow to one or more levels during the

operational period, which is automatically

set according to the seasons.

Dali remote lighting management systemWith the two-way digital DALI protocol

lighting levels can be adjusted,

consumption and system diagnostics

monitored. Inside the product on the

cabling board, space has been made

to accommodate an electronic unit

for remote management functionalities.

performance: enerGY SavinG

Proper management of electronic luminous flux means benefits in terms of energy saving and life cycle of the product.

Philips Xitanium Constant Current Xtreme Supply

The light output of the system is kept consistent throughout the life of the product by acting on the current supplied and compensating for the decay of the source.

Dimming preset cycle: from the switching on to 22:00 the 100% of luminous flux is guaranteed; from 22:00 until shut-down the guaranteed flux is 70%.

ncl - KeepinG floWS conSiStent

nvl - StanD-alone SettinG

energy use without ncl energy use with ncl

Savings

Switch on Switch off

energy savings

18:00 22:00 04:00

operating hrs (will vary over year)

Dim operating for 6 hrs (22:00-4:00 / 70%)

normal operation

luminous flux / normal operation

Time (in years) Time (in years)

luminous flux

power

power

10 10

Time (in hrs)

100% (Normal operation)power

70% (Night mode)

Page 8: Neri - Archilede S

proper thermal management is critical for smooth operations and long life of leD light sources. archilede Special is equipped with a heat dissipation system which keeps the junction temperature lower, extending the life of the light source.

Page 9: Neri - Archilede S

14 Neri · Archilede Special

Heat dissipation, crucial for the system

efficiency, has been properly integrated

with the product design. Through

channels dedicated to individual LEDs,

physical contact between light source

and aluminium cover ensures the right

orientation of the transmitted heat.

The system allows the luminaire to be

used at temperatures up to 50°C, keeping

the LED junction temperature below the

threshold to guarantee the expected life.

performance: heat DiSSipation

Thermal scan at temperatures of 25°C.

Page 10: Neri - Archilede S

1716 Neri · Archilede Special neri.biz

Archilede Special was developed to be

easy to install and maintain. Parts can

be replaced in few quick steps.

cover opening

Accidental anti-closuremechanism.

removing control gear

maintenance

Fast plug. Lever to unhook the control gear without tools.

Removing the control gear and fast connector on PCB.

maintenance

Page 11: Neri - Archilede S

18 Neri · Archilede Special

technical featUreS

fixing• Suitable for the top of a pole or side

mounting from Ø 60mm to Ø 76mm

• Tilting system up to 20° (5° step)

materials• Die-cast aluminium EN AB - 46100

• Screen in tempered transparent flat glass

• Stainless steel fasteners

painting• Powder coating RAL 9007

Structure - main components• Opening aluminium cover to access

wiring and optical compartment for

heat dissipation

• Lower frame in aluminum, for fastening

the coupling to the pole and for wiring

and screen support

• Silicone gasket between aluminium

lower frame and cover

• Extra-clear tempered glass screen

with impact resistance IK09 (EN 62262)

• Osmotic valve to balance internal /

external pressure

electrical auxiliaries• Programmable electronic power supply

• Automatic disconnector when opening

• Terminals wires max. section of 2.5mm2

• PG16 cable gland

• Additional inputs for data cable

(Plus version) with cable gland PG16

• Control gear with appropriate space for

auxiliary devices of remote management

power supply• Programmable electronic power supply

with functions: NCL, NVL, DALI, 1-10 V,

• Protected against short circuit,

over-temperature and over-voltages

up to 4kV

• Estimated life (Ta 25°C): > 100,000h, B10

Bracket with a tilting system up to 20° (5° step).

0 | +20°

0 | -20°

Page 12: Neri - Archilede S

2120 Neri · Archilede Special neri.biz

liGhtinG featUreS

planning photometric light distribution

main technical Data

SUpplY voltaGe220V-240V, 50/60Hz frequency

SUrGe protection4kV L-N / 4kV L/N-frame

poWer SUpplYProgrammable Electronic

poWer factor correctionPFC > Cos φ 0.9

electrical inSUlationClass II

encloUSUre protectionWater and dust IP66Mechanical impacts IK09

planninG informationSFor information related to the combinations between flux size options, power and colour temperature see the web site–Neri SpA reserves the right to modify its products and documentation without obligation to give prior warning

pedestrian crossings (nlG 23)Calculations to establish the required vertical lighting levels are necessary to position the light.

tYpe v - rotoSYmmetrical (nlG 18)

CLASSH 6m, A 20×20m H 6m, A 22×22m

Spacing Flux Spacing Flux

S1 20m* 9,000lm - -

S3 - - 22m* 6,000lm

* on both sides

Screen Shape

FLAT TRANSPARENT GLASS - Full cut off

optic SYStem

TyPE II - ASYMMETRIC ROAD OR CYCLE PATH (NLG 20)

TyPE III - ASYMMETRIC ROAD (NLG 21)

TyPE III - ASYMM. ROAD WITH SIDEWALK AND CYCLE PATH (NLG 22)

TyPE IV - STRONG ASYMMETRIC (NLG 17)

TyPE V - ROTOSYMMETRICAL (NLG 18)

PEDESTRIAN CROSSINGS (NLG 23)

coloUr temperatUre

3,000K

4,000K

flUX SiZeS optionS 3,000K

3,500lm 37W 94lm/W

4,500lm 46W 98lm/W

6,000lm 67W 89lm/W

7,500lm 83W 90lm/W

9,000lm 105W 86lm/W

10,500lm 106W 99lm/W

12,000lm 128W 94lm/W

flUX SiZeS optionS 4,000K

3,500lm 34W 103lm/W

4,500lm 42W 107lm/W

6,000lm 56W 107lm/W

7,500lm 69W 109lm/W

9,000lm 82W 110lm/W

10,500lm 94W 112lm/W

12,000lm 112W 107lm/W

13,500lm 132W 102lm/W

Driver fUnctionS

1 - 10V

DALI

NVL

electrical DeviceS

AUTOMATIC DISCONNECTOR

tYpe iii - aSYmm. roaD With SiDeWalK (a) anD cYcle path (b) (nlG 22)

CLASSH 7m, W 7m W 2m H 8m, W 7m W 2m

Spacing Flux (a) (b) Spacing Flux (a) (b)

CE1 (30 lux) 21m 9,000lm S1 S2 23m 9,000lm S2 S4

CE2 (20lux) 27m 9,000lm S2 S2 24m 7,500lm S2 S4

ME3b 26m 7,500lm S2 S3 22m 7,500lm S2 S4

tYpe ii - aSYmmetric roaD or cYcle path (nlG 20)

CLASSH 5m, W 3m H 9m, W 8m H 9,5m, W 8m TI (%)

Spacing Flux Spacing Flux Spacing Flux

S1 27m 3,500lm - - - - -

ME1 - - - - 27m 13,500lm 10%

ME2 - - - - 35m 13,500lm 10%

ME3b - - 36m 9,000lm - - 11%

ME4b - - 41m 9,000lm - - 11%

tYpe iii - aSYmmetric roaD(nlG 21)

CLASSH 7m, W 8m H 8m, W 8m TI (%)

Spacing Flux Spacing Flux

ME1 - - 28m 13,500lm 10%

ME2 26m 9,000lm - - 10%

ME3 31m 9,000lm - - 10%

CE2 (Uo 0.4) - - 29m 9,000lm -

tYpe iv - StronG aSYmmetric (nlG 17)

CLASSH 7m, A 39×21m H 7m, A 44×25m H 7m, A 39×34m

Spacing Flux Spacing Flux Spacing Flux

S1 - - - - 34m 13,500lm

S2 21m* 9,000lm - - - -

S4 - - 25m* 6,000lm - -

* on both sides

Page 13: Neri - Archilede S

23neri.biz

main features • Archilede Special is part of the

‘Performance’ category devices

• Especially suitable for roads and streets

with mixed traffic, essentially vehicular

• Designed in full compliance with the

lighting standards, with minimal energy

consumption, using LEDs and high

performance optical solutions

• Designed to reduce glare, without

compromising the lighting effectiveness

flux sizes• The main factor in lighting design

is system flux and photometry

• Neri presents products with their flux

sizes, to ensure these values remain

constant over time

the flux sizes approach permits: • Same light independently by the number

of LEDs

• Using the best technology on the market

(easy upgrade)

multilayer Archilede Special adopts a technology

with multilayer lenses:

• Each LED is associated to a lens

• All lenses are equal to each other and

cover the entire area to be lit; in case

of failure of a single source, there isn’t

any loss in the uniformity of illumination

on the ground

light emitting areaThe glaring effect, typical of the individual

point sources, is drastically reduced due

to some technical devices:

• PCB, color white

• Perimeter reflector

• Large light emitting area

hiGhliGhtS

On the left, from top to bottom, diagrammatic views of LEDs without multilayer lenses. On the right, from top to bottom, LEDs with multilayer lenses.

Page 14: Neri - Archilede S

24 Neri · Archilede Special

verSionS anD coDeS

coDe

mnarcl

coDe

mnarcl

coDe optic

17 Type IV

18 Type V

20 Type II

21 Type III

22 Type III

23 Pedonale

coDe optic

17 Type IV

20 Type II

21 Type III

22 Type III

coDe cct flux

1e1 3,000K 3,500lm

1e2 3,000K 4,500lm

1e3 3,000K 6,000lm

1e4 3,000K 7,500lm

1e5 3,000K 9,000lm

3e1 4,000K 3,500lm

3e2 4,000K 4,500lm

3e3 4,000K 6,000lm

3e4 4,000K 7,500lm

3e5 4,000K 9,000lm

coDe cct flux

1e6 3,000K 10,500lm

1e7 3,000K 12,000lm

3e6 4,000K 10,500lm

3e7 4,000K 12,000lm

3e8 4,000K 13,500lm

coDe Driver functions

02 1-10V + NCL

06 DALI + NCL

14 NVL + NCL

coDe Driver functions

05 DALI

13 NVL

archilede Special (from 3.500lm to 9.000lm)

archilede Special (from 10.500lm to 13.500lm)

In order to configure the Archilede Special

luminaire, optic, luminous flux related to

colour temperature and driver functions

need to be chosen.

Their related codes have then to be added

in sequence one to the other, following the

order of the tables below, starting from base

code (mnarcl), optic (eg: 17), luminous flux

(eg: 1e1) and driver (eg: 02). The code of the

chosen configuration will be:

mnarcl 17 1e1 02.

Page 15: Neri - Archilede S

neri S.p.a.S.S. emilia 162247020 longiano (fc) · italyt +39 0547 652111f +39 0547 54074

neri north america inc.1835 nW 112th avenue Suite 176miami, fl 33172 · USat +1 786 315 4367f +1 786 257 1336

neri liGhtinG (inDia) pvt. ltD.14, Bhattarahalli · K r puramBengaluru · 560049t +91 80 30 613 658

Neri Branch office

DUBai neri S.p.a. (Jlt Branch)29-13 reef tower cluster oJlt - Jumeirah lake towersp.o. Box: 115738 · Dubai · Uaet +971 4 448 7246f +971 4 448 7112

www.neri.biz© July 2015 · neri S.p.a.