AUDIT ACCESS universiti kebangsaan malaysia Disediakan oleh: Mastor Surat NurAkmal Goh Abdullah Mazlan Mohd Tahir Jabatan Seni Bina, Fakulti Kejuruteraan Dan Alam Bina Universiti Kebangsaan Malaysia [email protected] TAKLIMAT PENAMBAHBAIKAN STRUKTUR MESRA PELANGGAN UNTUK KEPERLUAN MQA Bilek Senat, Bangunan Canselori Universiti Kebangsaan Malaysia 11hb. Februari, 2009 Anjuran Pusat Pembangunan Akademik, UKM GUIDELINES ON ACCESS FOR DISABLED PERSONS TO PUBLIC BUILDINGS

OKU Malaysian Standard

Embed Size (px)

Citation preview

Page 1: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

Disediakan oleh:

Mastor SuratNurAkmal Goh Abdullah

Mazlan Mohd TahirJabatan Seni Bina, Fakulti Kejuruteraan Dan Alam Bina

Universiti Kebangsaan [email protected]

TAKLIMAT PENAMBAHBAIKAN STRUKTUR MESRA PELANGGAN UNTUK KEPERLUAN MQA

Bilek Senat, Bangunan CanseloriUniversiti Kebangsaan Malaysia

11hb. Februari, 2009

AnjuranPusat Pembangunan Akademik, UKM

GUIDELINES ON ACCESS FOR DISABLED PERSONS

TO PUBLIC BUILDINGS

Page 2: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

INTERPRETATION

Disabled persons refer to people with a physical, hearing or sight impairment or any combination thereof, which affects their mobility outside building or their use of buildings and related amenities

Malaysian Standard

Page 3: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

INTRODUCTION

At the beginning of the 20 century, the average human lifespan was onlyabout 47 years. People are now living longer today. The average lifespanhas increased to about 76, largely due to healthier living, and better medicine.

In addition, more people are now living with disability, as medical advanceshave also enabled people to survive illness and accidents, which werepreviously fatal.

Page 4: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

INTRODUCTION (Contd...)

These demographic changes resulted in a population that is older and more disabled than many realize and these trends continue. Both globally as well as in Malaysia.

For example, Hong Kong in 2006 will have over one-third of its population over 60 years of age. In Japan, a quarter of its population will be 65 and over in 2015. Singapore by the year 2030 is expected to have one-fifth of its population over 65 years of age.

Page 5: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

BARIER FREE GUIDELINES

In the past, community attitudes and physical barriers in the built environment may have prevented people with disabilities from fully participating in society.

The MS 1184:1991 Code of Practice on Access for Disabled People to Public Buildings was first introduced in Malaysia in 1991, followed by MS1331:1993 Code of Practice on Access for Disabled People Outside Buildings in 1993. It was then written primarily with the needs of wheelchair users in mind, and was followed with its second edition of the revised Code in 2002 and 2003 respectively.

Page 6: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

BARIER FREE GUIDELINES (Contd.)

Since that time, accessibility for wheelchair users has now become a standard feature in most of our new buildings. With this, it has also become more and more common to see wheelchair users moving about freely on their own, or with friends and families.

As we all know, even if a person is unable to walk or if a person is without sight, or without hearing, the person’s other facilities continue to function. The person will continue to possess, his or her mind and intellect, imaginations as well as aspirations.

Page 7: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

The “barrier-free” design guidelines will help considerably towards greater independence of not only wheelchair users, but also hopefully, the elderly, the visually or hearing impaired, children, and indeed a broad spectrum of the community.

BARIER FREE GUIDELINES (Contd.)

Page 8: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

MALAYSIAN STANDARD

MS 1331 : 2003 (MS 1331 : 1993)CODE OF PRACTICE FOR ACCESS OF DISABLED PERSONS OUTSIDE BUILDINGS

MS 1184 : 2002 (MS 1184 : 1991)CODE OF PRACTICE ON ACCESS FOR DISABLED PERSONS TO PUBLIC BUILDINGS

MS 2015 :PART 1 : 2006PUBLIC TOILETS – PART 1 : MINIMUN DESIGN CRITERIA

BARIER FREE GUIDELINES (Contd.)

Page 9: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

The guidelines aimed at creating an inclusive, barrier-free and rights-base society for people with disabilities, thereby systematically improving their living conditions inside and outside buildings and enabling them to achieve their total development potential.

Malaysian Standard

BARIER FREE GUIDELINES (Contd.)

Page 10: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

The main features designers have to look out for when designing a building

The main considerations include facilities for persons with disabilities e.g. toilets, carparks, etc,

movement from one level to another e.g. ramps, lifts, etc,

opening widths and maneuvering spaces at doors, passageways and internal spaces and

signages within or outside the building.

BARIER FREE GUIDELINES (Contd.)

Page 11: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

The items

. Vehicle parking and access

. Pathways and ramps

. Main entrances

. Step ramps

. Doors and doorways

. Stairs

. Lifts

. Escalators

. Handrails

. Grab rails

. Circulation spaces

. Guiding blocks

. Toilet requirements

. Water closets

. Urinals

. Shower facilities

Malaysian Standard

BARIER FREE GUIDELINES (Contd.)

Page 12: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

The scope (contd.)

. Washbasin and other facilities

. Bath

. Combined water closet and shower recess

. Shelving and wall units

. Work surfaces

. Projections, guard rails, openings and drops. Finishes. Controls for use by disabled persons. Signs and symbols. Announcements, signals and warnings for people with detective sight or hearing impaired. Landscape. Hotel bedrooms

Malaysian Standard

BARIER FREE GUIDELINES (Contd.)

Page 13: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

A CONNECTIVITY

i. External Accessible Route

Seamless connectivity with public transportation nodes

Seamless connectivity with public street(s) and sidewalk(s) with adjacent developments

ii. Access to building

Provision of ramp and steps to entrance

Automatic doors at accessible entrance

FEATURES TO EMULATE

Page 14: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

A CONNECTIVITY

iii. Horizontal Circulation

Wide circulation path to accommodate projected human traffic volume and

wheelchair users

iv. Vertical Circulation

More than 1 accessible lift for wheelchair users and serving all floors

Accessible lift located in main circulation area

FEATURES TO EMULATE (Contd.)

Page 15: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

B ACCESSIBILITY

i. External Accessible Facilities

Brightly lit and well ventilated car park

• Conspicuous accessible car park lots for wheelchair users painted in colour different from other lots

• Accessible car park lots positioned next to lift lobby providing direct, smooth and short transfer

Pedestrian lanes in the car park to enhance safety of users

FEATURES TO EMULATE (Contd.)

Page 16: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

C Space Allowances

Minimum clear floor space of 900mm x 1200mm is required to

accommodate a single stationarywheelchair

Minimum clear floor space of 1800mm x 1800mm is required to turn a wheelchair

FEATURES TO EMULATE (Contd.)

Page 17: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

D Gradient for Ramp

Changes in vertical rise 0-15mm : Gradient not steeper than 1:2

Changes in vertical rise 15.1-50mm : Gradient not steeper than 1:5

Changes in vertical rise 50.1-200mm : Gradient not steeper than 1:10

Changes in vertical rise exceeding 200 : Gradient not steeper than 1:12

FEATURES TO EMULATE (Contd.)

Page 18: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

E Handrails / Grab bars

• Should be easy to grasp• Should be slip-resistant• Should provide firm and comfortable grip• Should slide along the rail without

obstruction• Should have appropriate diameter• Should be at the proper height

Diameter:- Adults : should be 30mm to 45 mm- Children : should be 30mm to 35 mm

Height of the Handrails / Grab Bars:- Adults : should be 800mm to 900 mm- Children : should be 580mm to 700 mm

(7 – 12 years)

FEATURES TO EMULATE (Contd.)

Page 19: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

F Seating Space

Provided at counters, tables or work surfaces for W/C users1. Clear floor space: 900mm x 1200mm(same for children & adults

Provided at counters, tables or work surfaces for W/C users2. Clear Knee space:• Adults : 900mm wide x 480mm deep x 700mm high• Children : 700mm wide x 400mm deep x 680mm high

Provided at counters, tables or work surfaces for W/C users3. Counter tops:• Adults : shall not be more than 800mm from the floor.• Children : shall be at a height between 700mm to 780mm.

FEATURES TO EMULATE (Contd.)

Page 20: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

G Drinking Fountain (For Wheelchair users)

Spout Opening of the Drinking Fountain:

• Adults : An opening located between 750mm to 900mm.

• Children : An opening located between 740mm to 780mm.780

FEATURES TO EMULATE (Contd.)

Page 21: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

H Sanitary Provisions

1. Water closet:

Height of the water closet seat of 450mm to 480mm is recommended for wheelchair and ambulant disabled users of all agegroups to facilitate transfer

Distance between the centre line of the water closet to the adjacent wall shall be 460-480mm

FEATURES TO EMULATE (Contd.)

Page 22: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

H Sanitary Provisions

2. Grab bars:

Two Horizontal grab bars one at the sidewall and another at the wall behind the water closet shall be mounted at a height between 640mm to 740 mm.

At least 450mm extended in front of the seat

At least 750mm long750 min 450 min

FEATURES TO EMULATE (Contd.)

Page 23: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

H Sanitary Provisions

3. Urinal:

Urinal mounted at a height of not more than 400mm from the finished floor level should be provided for ambulant children with physical disabilities.

FEATURES TO EMULATE (Contd.)

Page 24: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

H Sanitary Provisions

4. Wash basin:

700 wide x 400mm deep x 680mm high.

The rim or counter surface should not be higher than 780mm.

A wash basin with adjustable height is more appropriate to serve the needs of different age group.

FEATURES TO EMULATE (Contd.)

Page 25: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

H Sanitary Provisions

5. Mirror:

Mirror from maximum 800mm above the floor level to the top most edge of minimum 1900mm is recommended for all people including children and adults (both ambulantand wheelchair users).

A clear floor space of 900mm x 1200mm should be provided in front of the mirror.

Page 26: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

I Lift

The lift control panel for children with disabilities should be placed at a height between 800mm and 100mm from the floor level 1000 max 800 max

FEATURES TO EMULATE (Contd.)

Page 27: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

J Public Telephone

The height of the operable parts of a telephone should be between the height of 800mm to 1000mm

FEATURES TO EMULATE (Contd.)

Page 28: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

K Tuckshop / Canteen

Height of the tables or counters should notbe higher than 780mm where the disabledchildren on wheelchair are principal orpredominant users.

A clear floor space of 900mm by 1200mmshould be provided at the front of theseating space for wheelchair users.

A clear knee space of 700mm wide by400mm deep by 680mm high should beprovided.

FEATURES TO EMULATE (Contd.)

Page 29: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

L Computer Room

The computer’s central processing unit,monitor, Printer, key board, mouse andother accessories should be within the reachof the users.

A clear floor space of 900mm by 1200mmshould be provided at the front of theseating space for wheelchair users.

A clear knee space of 700mm wide by400mm deep by 680mm high should beprovided.

A table with adjustable height isrecommended

FEATURES TO EMULATE (Contd.)

Page 30: OKU Malaysian Standard

AUDIT ACCESS universiti kebangsaan malaysia

M Library

Where the revolving doors or turnstiles are provided at the entrance an adjacent accessible gate should beprovided.

Height of the tables or counters should not be higher than 780mm where the disabled children on wheelchair are principal or predominant users.

A clear floor space of 900mm by 1200mm should be provided at the front of the seating space forwheelchair users.

A clear knee space of 700mm wide by 400mm deep by 680mm high should be provided.

A table with adjustable height is recommended

FEATURES TO EMULATE (Contd.)

Page 31: OKU Malaysian Standard

UKM-OUP-PLW-11-48/2008 universiti kebangsaan malaysia

Mastor SuratJabatan Seni BinaFakulti Kejuruteraan & Alam BinaUniversiti Kebangsaan Malaysia43600 UKM Bangi SelangorMalaysia

Website: http://www.eng.ukm.myEmail: [email protected]

[email protected]. No: +603-8921 6299Fax No: +603-8921 6841

TERIMA KASIH & WASSALAM