8
membrane glass H H H H H H H S
membrane resistance (25°C) [MΩ] 300 300 300 300 300 300 300 400
temperature range [°C] 0...135 0...135 0...135 0...135 0...135 0...135 0...135 10...135
pH range [°C] 0...14 0...14 0...14 0...14 0...14 0...14 0...14 2...14
pressure range p/∆p [bar] 10/3 6/3 6/3 6/3 10/3 6/3 6/3 10/3
length L [mm] 170 120 320 170 170 120 320 170
diaphragm ceramic
platinum
ground joint
certified press. and temp. consistency 1)
design corresponding illustration A A A B A A A A
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.
pH combination electrodes with liquid electrolyte and screw plug head
H 618
1 HD
H 628
1
H 638
1
H 648
1
H 619
1 HD
H 629
1
H 639
1
S 61
81 H
D
A H 6191 HDH 6181 HDH 6281H 6381H 6291H 6391S 6181 HDS 6281S 6381S 6191 HDS 6291S 6391L 6191
B H 6481S 6481
L
9
S S S S S S L
400 400 400 400 400 400 30
10...135 10...135 10...135 10...135 10...135 10...135 -30...+80
2...14 2...14 2...14 2...14 2...14 2...14 0...12
6/3 6/3 6/3 10/3 6/3 6/3 6/3
120 320 170 170 120 320 170
(triple)
A A B A A A A
S 62
81
S 63
81
S 64
81
S 61
91 H
D
S 62
91
S 63
91
L 61
91
pH combination electrodes with liquid
electrolyte and screw plug head
For high sophisticated pH measurements in
chemical processes.
Electrolyte:
3 mol/l KCl (Type L 300), refillable
except L 6191: low temperature electrolyte
type L 200
Zero point:
pH = 7.0
Shaft diameter:
12 mm
Connection:
screw plug head coaxial
with thread Pg 13.5
The use of these electrodes is chiefly intended in
combination with the miniature pressure probe
assembly 9921/51 HD and suitable pressure hose
type 9961/09. This assembly reduces the stated
installation length by 50 mm. The side support
with screw fitting serves for application of counter
pressure.
Supply:
HD version: HD sealing type 9980/51
standard: washer 9980/52,
O-ring type 9932/07
Connecting cable:
e.g. type 9902/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
Note:
at temperatures above 100 °C sufficient over-
pressure must counteract the boiling of the
reference electrolyte, e.g. 3.2 bar at 135 °C.
10
membrane glass L L L H H H S
membrane resistance (25°C) [MΩ] 30 30 30 300 300 300 400
temperature range [°C] - 30...+80 -30...+80 -30...+80 0...135 0...135 0...135 10...135
pH range 0...12 0...12 0...12 0...14 0...14 0...14 2...14
pressure range p/∆p [bar] 6/3 6/3 6/3 6/3 6/3 6/3 6/3
length L [mm] 120 120 120 120 120 120 120
diaphragm ceramic (triple)
platinum
ground joint
design corresponding illustration A B A A B A A
pH combination electrodes with liquid electrolyte and hose olive
L 90
80
L 91
80
L 90
90
H 908
0
H 918
0
H 909
0
S 90
80
A L 9080L 9090H 9080H 9090S 9080S 9090
B H 9180L 9180S 9180
L
11
S S
400 400
10...135 10...135
2...14 2...14
6/3 6/3
120 120
B A
S 91
80
S 90
90
pH combination electrodes with liquid
electrolyte and hose olive
For high sophisticated pH measurements in
chemical processes.
Electrolyte:
3 mol/l KCl (type L 300), refillable – except
L 9080, L 9180, L 9090: low temperature
electrolyte type L 200
Zero point:
pH = 7.0
Shaft diameter:
12 mm
Connection:
plug head coaxial
Design:
refilling opening as hose olive
shaft constriction
Supply:
pressure screw type 9980/55 with thread Pg 13.5
washer 9980/52
O-ring type 9932/06
Connecting cable:
e.g. type 9902/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
Note:
at temperatures above 100 °C sufficient overpres-
sure must counteract the boiling of the reference
electrolyte, e.g. 3.2 bar at 135 °C
The use of these electrodes is effected usually with
electrolyte reservoir (e.g. type 9955/00).
This vessel is connected by means of silicone tube
(e.g. type 9980/00) with the electrode.
12
membrane glass H H H S S S
membrane resistance (25°C) [MΩ] 300 300 300 400 400 400
temperature range [°C] 0...135 0...135 0...135 10...135 10...135 10...135
pH range 0...14 0...14 0...14 2...14 2...14 2...14
pressure range p/∆p [bar] 6/3 6/3 6/3 6/3 6/3 6/3
length L [mm] 120 120 120 120 120 120
diaphragm ceramic
platinum
ground joint
design corresponding illustration A B A A B A
pH combination electrodes with liquid electrolyte
9582
/85
9583
/85
9582
/95
9182
/85
9183
/85
9182
/95
pH combination electrodes with liquid
electrolyte
For high sophisticated pH measurements in
chemical processes. Specially for installation in
immersion probe assembly.
Electrolyte:
3 mol/l KCl (type L 300), refillable
Zero point:
pH = 7.0
Shaft diameter:
12 mm
Design:
refilling opening, double, at the side
shaft constriction and fixed cable 5 m
Note:
at temperatures above 100 °C sufficient overpres-
sure must counteract the boiling of the reference
electrolyte, e.g. 3.2 bar at 135 °C
A 9582/859582/959182/859182/95
B 9583/859183/85
L
13
membrane glass L L H H H H
membrane resistance (25°C) [MΩ] 30 50 400 400 400 400
temperature range [°C] - 5...+80 -5...+ 80 0...100 0...100 0...100 0...100
pH range 2...12 2...12 2...13 2...13 2...13 2...13
pressure range p/∆p [bar] 0,5 10 10 10 10 10
length L [mm] 120 120 170 120 360 225
electrolyte gel Referid® Referid® Referid® Referid® Referid®
diaphragm ceramic
KPG® annular gap
certified pressure and temperature consistency 1)
design corresponding illustration A B B B B B
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.
Low maintenance pH combination electrodes
L 77
81
L 82
81 H
D
H 818
1 HD
H 828
1 HD
H 838
1
H 848
1 HD
Low-maintenance pH combination
electrodes
For uncomplicated pH measurement in the water
industry and for process chemistry.
Electrolyte:
gel with visible KCl reserves, not refillable
Referid® (polymer with visible KCl reserves),
not refillable
Zero point:
pH = 7.0
Shaft diameter:
12 mm
Connection:
screw plug head coaxial with thread Pg 13.5
Supply:
HD version: HD sealing type 9980/51
standard: washer 9980/52, O-ring type 9932/07
Connecting cable:
e.g. type 9902/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
A L 7781
B H 8281 HDL 8281 HDH 8181 HDH 8381H 8481 HD
L
14
Metal combination electrodes
Ag 90
80
AgS 6
181
AgS 8
281
Au 90
80
Pt 9
080
Pt 6
881
Pt 6
981
HD
sensor silver silver silver gold platinum platinum platinum
sensor sulphidized
sensor form pin
disk
ring
temperature range [°C] - 5 ... +100 -5 ... +100 -5 ... +100 -5 ... +100 -5 ... +100 -5 ... +100 -5 ... +100
pressure range p/∆p [bar] 6/3 6/3 10 6/3 6/3 6/3 10/3
length L [mm] 120 170 120 120 120 120 170
electrolyte liquid, refillable
gel, low-maintenance
Referid®, low-maintenance
diaphragm ceramic
KPG® annular gap
certified pressure and temperature consistency 1)
design corresponding illustration A D B A A E E
Application recommendationswater management
process chemistry
photo
redox potential measurement
silver/halid ions concentration
determination of cyanide/rhodanide
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.
L
A Ag 9080Au 9080Pt 9080
B AgS 8281 Pt 8181 Pt 8281 HD
C Pt 7781
15
Pt 8
181
Pt 8
281
HD
Pt 7
781
Metal combination electrodes
For redox measurements in water industry and
process chemistry.
Electrolyte:
3 mol/l KCI (type L 300), refillable
except Ag S 6181: electrolyte type L 320 K
gel with visible KCl reserves, not refillable
Referid® (polymer with visible KCl reserves),
not refillable
Shaft diameter:
12 mm
Connection:
screw plug head with thread Pg 13.5
Supply (design A):
pressure screw type 9980/55
with thread Pg 13.5
washer 9980/52
O-ring type 9932/06
Supply (design B-E, except HD):
washer 9980/52
O-ring type 9932/07
Supply (HD version):
HD sealing type 9980/51
Connecting cable:
e.g. type 9902/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
Note (for electrodes with liquid electrolyte):
at temperatures above 100 °C sufficient overpres-
sure must counteract the boiling of the reference
electrolyte, e.g. 3.2 bar at 135 °C
platinum platinum platinum
- 5 ... +100 -5 ... +100 -5 ... +60
10 10 0,5
170 120 120
B B C
L
D AgS 6181
E Pt 6981 HDPt 6881
16
membrane glass L H H H H H S
membrane resistance (25°C) [MΩ] 30 300 300 2000 600 500 400
zero point at pH 7.0 4.6 7.0 7.0 7.0 7.0 7.0
temperature range [°C] - 30 ... +80 0 ...135 0 ...135 0 ...135 0 ...135 0 ...135 10 ...135
pH range [°C] 0 ... 12 0 ... 14 0 ... 14 0 ... 14 0 ... 14 0 ... 14 2 ... 14
sensor form sphere
dome
spear
shaft material glass
plastic
certified pressure and temperature consistency 1)
design corresponding illustration A A A A C B A
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.2) glass electrode with increased HF resistance3) pNa electrode for determination of sodium ion concentration, range of application pNa: 0 … 6, zero point pNa = 2.0
pH glass electrodes
A S 1181 HDL 1181 HDH 1171 H 1181 HDH 1191 HDS 1191 HDN 2981
B H 2781 HD
S 2781 HD
C H 1481 HD
D 9701/859501/759501/859101/859601/85
E 9517/859117/85
F 9504/85
L 11
81 H
D
H 117
1
H 118
1 HD
H 119
1 HD
H 148
1 HD
H 278
1 HD
S 11
81 H
D
L
17
S S N L H H H H S S Na
2000 600 100 30 300 300 600 500 400 600 300
7.0 7.0 7.0 7.0 4.6 7.0 7.0 7.0 7.0 7.0 3)
10 ...135 10 ...135 0 ... 50 -30 ... +80 0 ...135 0 ...135 10 ...135 10 ...135 10 ...135 10 ...135 0 ... 80
2 ... 14 2 ... 14 0 ... 14 0 ... 12 0 ... 14 0 ... 14 0 ... 14 0 ... 14 2 ... 14 2 ... 14 3)
A B A D D D F E D E D
S 11
91 H
D
S 27
81 H
D
N 298
12)
9701
/85
9501
/75
9501
/85
9504
/85
9517
/85
9101
/85
9117
/85
9601
/85
pH combination electrodes without
reference electrode
Single electrodes are useful if the life of glass and
reference electrode is significantly different. For
measuring the pH value, a separate reference elec-
trode is required.
Length L:
120 mm
Shaft diameter:
12 mm
Pressure range:
max. 10 bar
Connection and Design A-C:
screw plug head with thread Pg 13.5
Connection and Design D-F:
5 m fixed cable
flange cap
Supply (design A-C, except HD):
washer 9980/52
O-ring type 9932/07
Supply (HD version):
HD sealing type 9980/51
Supply (design D-F):
O-ring type 9932/07
pressure screw type 9980/55-14 has to be
ordered separately
Connecting cable (design A-C):
e.g. type 9902/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
18
sensor silver silver gold antimony platinum wolfram platinum
sensor sulphidized
sensor form pin
ring
sensor diameter [mm] 5 5 2 6 6 2 6
temperature range [°C] 0 ... 70 0 ... 70 0 ... 70 0 ... 70 -30 ...+135 -30 ...+135 0 ... 70
shaft material glass
PVDF
Polyamid-12
certified pressure and temperature consistency 1)
design corresponding illustration A A A A B A D
Application recommendationsredox potential
redox potential, rhodanide, cyanide
silver/halid ions concentration
pH measurement in HF bearing media
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.
Metal electrodes
Ag 11
01
AgS 1
101
Au 11
01
Sb 1
101
Pt 1
801
HD
W 1
101
9008
/15
A Ag 1101AgS 1101Au 1101Sb 1101W 1101
B Pt 1801 HD
C 9006/259006/359006/95
D 9008/15
L
19
silver gold antimony
5 2 6
0 ... 70 0 ... 70 0 ... 70
C C C
9006
/25
9006
/35
9006
/95
Metal electrodes without
reference electrode
Single electrodes are useful if the life of metal and
reference electrode is significantly different. For
measuring with single electrodes, a separate refer-
ence electrode is required.
Length L:
120 mm
Shaft diameter:
12 mm
Pressure range:
max. 10 bar
Connection and design A – B:
screw plug head with thread Pg 13.5
Connection and design C – D:
5 m fixed cable
flange cap
Supply (design A – B, except HD):
washer 9980/52
O-ring type 9932/07
Supply (HD version):
HD sealing type 9980/51
Supply (design C – D):
O-ring type 9932/07
pressure screw type 9980/55-14 has to be
ordered separately
Connecting cable:
e.g. type 9902/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
20
temperature range [°C] 0 ... 100 0 ... 100 0 ... 50 0 ... 50 -5 ... +135 -5 ... +135 -5 ... +135
pressure range p/∆p [bar] 10 10 10 0.5 10/3 10/3 6/3
length L [mm] 120 120 120 120 170 170 170
electrolyte liquid (type L 300)
gel (KCI saturated)
Referid® (visible KCl reserves)
liquid (type L 200)
internal resistance (25°C) [KΩ] 2 2 2 2 3 3 2
shaft material glass
PVDF
diaphragm ceramic
KPG® annular gap
platinum
PVDF
ground joint
frit
certified pressure and temperature consistency 1)
design corresponding illustration A B B C G G F
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.
Reference electrodes
B 19
81 H
D
B 18
81 H
D
B 11
81 H
D
9801
/85
B 13
91 H
D
B 14
91 H
D
B 15
91
A B 1981 HD
B B 1181 HDB 1881 HD
C 9801/85
D 9828/95
E 9834/95
L
F B 1591
G B 1491 HDB 1391 HD
21
-5 ... +135 -30 ... +50
6/3 6/3
120 120
3 1
D E
9828
/95
9834
/95
Reference electrodes
Single electrodes are useful if the life of measuring
and reference electrode is significantly different.
Shaft diameter:
12 mm
Connection and design A, B, F, G:
screw plug head coaxial with Pg 13.5
Connection and design C:
5 m fixed cable
flange cap
Connection and design D + E:
5 m fixed cable
refilling opening as hose olive
shaft constriction
Supply (design A, B, F, G, except HD):
washer 9980/52
O-ring type 9932/07
Supply (HD version):
HD sealing type 9980/51
Supply (design C):
O-ring type 9932/07
pressure screw type 9980/55-14 has to be
ordered separately
Supply (design D + E):
pressure screw type 9980/55 with thread Pg 13.5
washer 9980/52
O-ring type 9932/06
Connecting cable (design A, B, F, G):
e.g. type 9905/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
Note (for electrodes with liquid electrolyte):
at temperatures above 100 °C sufficient overpres-
sure must counteract the boiling of the reference
electrolyte, e.g. 3.2 bar at 135 °C
L
22
temperature range [°C] - 5 ... +135
pressure range p/∆p [bar] 3/3
length L [mm] 95
internal resistance (25°C) [KΩ] 2
diaphragm ceramic
material of head PPS
design and connection 5 m fixed cable
Detachable reference electrode, according to DIN 19 264
9871
/95
Detachable reference electrode, according
to DIN 19 264
Preferably for measuring pH in industrial plants.
Advantage: Reference electrode and electrolyte
vessel can be replaced. The detachable reference
electrode must be accompanied by a suitable elec-
trolyte vessel (see page 24).
Electrolyte:
KCl saturated, refillable
Supply:
O-ring type 9932/05
9871/95
L
23
Reference electrodes are used outside the tempera-
ture application ranges stated in this catalogue
with the help of an electrolyte bridge. For applica-
tions below 0 °C, the low temperature electrolyte
L 200 or the low temperature reference electrode
9834/9 respectively must be used. For applications
above 100 °C, a sufficient overpressure must coun-
teract the boiling of the reference electrolyte, eg
3.2 bar at 135 °C. Electrodes with liquid electrolyte
render, in a corresponding pressure application, a
higher temperature employment range and
a longer life than low-maintenance electrodes.
In the case of liquid electrolyte electrodes,
a higher measuring accuracy can be expected.
Which reference electrode to which measuring electrode
reference electrodes with fixed cable reference electrodes with plug head, inst. thread
9801/8. 9828/9. 9834/9. 9871/9. B1181HD B1391HD1) B1491HD1) B15911) B1881HD B1981HD
9101/8. « ∑ « ® « ∑ ∑ « « «
9117/8. « ® « ∑ « ∑ ∑ « « «
9501/7. « ® « ∑ « ∑ ∑ ∑ ∑ «
9501/8. « ∑ « ® « ∑ ∑ ∑ ∑ «
9504/8. « ® « ∑ « ∑ ∑ « « ∑
9517/8. « ® « ∑ « ∑ ∑ ∑ ∑ «
9701/8. « ∑ ® ∑ « ∑ ∑ ∑ « «
9006/2. « ® « ∑ « « ∑ ∑ « ∑
9006/3. ∑ ® « ∑ ∑ « ∑ ∑ ∑ ∑
9006/9.2)« « « « « « « « ® «
9008/1. ∑ ® « ∑ ∑ « ∑ ∑ ∑ ∑
9601/8. ® ∑ « « ∑ ∑ ∑ ∑ ∑ «
L 1181 HD « ∑ ® ∑ ∑ ∑ ∑ ∑ « «
H 1171 ∑ ∑ « ∑ « ∑ ® ∑ ∑ «
H 1181 HD « ∑ « ∑ « ∑ ® ∑ ∑ «
H 1191 HD « ∑ « ∑ « ∑ ® ∑ ∑ «
H 1481 HD « ∑ « ∑ « ∑ ∑ « « ®
H 2781 HD « ∑ « ∑ « ∑ ∑ ® ∑ «
N 29812)« « « « « « « « ® «
S 1181 HD « ∑ « ∑ « ® ∑ « « «
S 1191 HD « ∑ « ∑ « ® ∑ « « «
S 2781 HD « ∑ « ∑ « ® ∑ « « «
Ag 1101 « ∑ « ∑ « « ® ∑ « ∑
AgS 1101 « ∑ « ∑ « « ® ∑ ∑ ∑
Au 1101 « ∑ « ∑ ∑ « ® ∑ ∑ ∑
Pt 1801HD « ∑ « ∑ ∑ « ® ∑ ∑ ∑
Sb 11012)« « « « « « « « ® «
W 1101 « ∑ « ∑ ∑ « ® ∑ ∑ «
1) To be used only with miniature pressure adapter type 9921/51 HD2) Use of other reference electrodes to be recommended only with the use of electrolyte key 9844/21 or B 4491
® = recommended; application outside the stated temperature application ranges with electrolyte bridge
∑ = suitable; application outside the stated temperature application ranges with electrolyte bridge
« = conditionally suitable; suitable depending on the application and installation of the measuring point;
under certain circumstances the use of an electrolyte bridge is advisable.
pH glass electrodes
with fixed cable
metal electrodes
with fixed cable
pNa glass electrode
with fixed cable
pH glass electrodes with plug
head and installation thread
metal electrodes with plug head
and installation thread
24
temperature range [°C] 0 ...135 -10 ... +135 0 ...135 -30 ... +135 0 ...135 0 ...135 0 ...135
pressure range p/∆p [bar] 3/3 3/3 3/3 3/3 3/3 3/3 3/3
internal resistance (25°C) [KΩ] 1.5 0.5 0.1 0.1 1.5 0.5 0.5
diaphragm ceramic
triple ceramic
ground joint
frit
platinum (side)
permeability [ml/h] 1) 0.05 0.15 2 2 0.05 0.1 0.15
reservoir (vessel) height [mm] 35 35 35 35 85 85 85
design corresponding illustration A A A A B B B
1) Average values at overpressure of 0.1 bar.
Electrolyte vessels for detachable reference electrodes, accordingto DIN 19 264
9863
/01
9863
/03
9863
/04
9863
/05
9864
/01
9864
/02
9864
/03
A 9863/019863/039863/049863/05
B 9864/059864/019864/029864/039864/049864/07
L
25
0 ...135 -30 ... +135 0 ...135
3/3 3/3 3/3
0.1 0.1 0.5
2 2 0.1
85 85 85
B B B
9864
/04
9864
/05
9864
/07
Electrolyte vessels for detachable reference
electrodes, according to DIN 19 264
Length L:
120 mm
Shaft diameter:
12 mm
Design:
shaft constriction
Shaft material:
glass
Supply:
pressure screw type 9980/55 with thread Pg 13.5
washer 9980/52
O-ring type 9932/06
26
temperature range [°C] 0 ...135 0 ...135 0 ...135 0 ...135 0 ...135 0 ...135 0 ...135
pressure range p/∆p [bar] 6/3 6/3 6/3 6/3 6/3 6/3 6/3
internal resistance (25°C) [KΩ] 1.5 1.5 1.5 0.5 0.1 0.1 0.1
shaft material glass
PTFE
PVDF
diaphragm frit
platinum
ground joint
ceramic (triple)
PTFE
permeability [ml/h] 1) 0.05 0.05 0.05 0.15 2 2 2
design corresponding illustration A C F F A C F
1) Average values at overpressure of 0.1 bar.
Electrolyte bridges for reference electrodes
A B 4441B 4411B 4451B 4471
B B 4491
C 9844/119844/149844/15
D 9844/21
E 9844/26(Ill. withpressure screw)
F 9844/019844/039844/049844/059844/029844/07
B 44
11
9844
/11
9844
/01
9844
/03
B 44
41
9844
/14
9844
/04
L
27
-30 ... +135 0 ...135 -30 ... +135 0 ...135 0 ...135 0 ...135 0 ...135 0 ...135 0 ...135
6/3 6/3 6/3 6/3 6/3 6/3 2/2 2/2 6/3
0.1 0.1 0.1 0.5 0.5 0.5 1.5 1.5 1.0
(side)
2 2 2 0.1 0.1 0.1 4 4 0.1
A C F A F F B D E
B 44
51
9844
/15
9844
/05
B 44
71
9844
/02
9844
/07
B 44
91
9844
/21
9844
/26
Electrolyte bridges for reference electrodes
Accessory for sophisticated pH measurement in
chemical processes. An electrolyte bridge is advis-
able if the measuring solution contains strong
electrode poisons or if the electrolyte of the refer-
ence electrode reacts with the measuring solution.
Hose olive:
d = 10 mm (except type 9844/26: d = 4 mm)
Length L:
120 mm
Shaft diameter:
12 mm
Design A + B:
thread Pg 13.5
Design C - E:
flange cap
Design F:
shaft constriction
Supply (design A + B):
washer 9980/52
O-ring type 9932/07
Supply (design C – E):
pressure screw type 9980/55-14 with
thread Pg 13.5
O-ring type 9932/07
Supply (design F):
pressure screw type 9980/55 with
thread Pg 13.5
washer 9980/52
O-ring type 9932/06
Accessories:
hose type 9980/00
(except for 9844/26: hose type 9961/09)
spare diaphragm for 9844/21 and B 4491:
type 9980/65
28
sensor Pt 100
sensor Pt 1000
secondary platinum electrode
pressure range [bar] 10 10 10 10 10 10 10
shaft material stainless steel 1.4571
glass
DURAN®
PVDF
connection 2-pole 2-pole 4-pole 2-pole SMEK SMEK SMEK
certified pressure and temperature consistency 1)
design corresponding illustration A B C D A C D
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.
Resistance thermometers with plug head
W 2
021
W 2
041
W 2
061
W 2
081
W 2
021
HD
W 2
061
HD
W 2
081
HD
A W 2021 HDW 2021W 4011W 2121W 4111
B W 2041
C W 2061 HDW 2061W2161
D W 2081W 2081 HDW 4081W 2181
L
29
(double)
10 10 10 10 10 10
4-pole 2-pole 2-pole 4-pole 2-pole 2-pole
D A A C D A
W 4
081
W 4
011
W 2
121
W 2
161
W 4
111
W 2
181
Resistance thermometers with plug head
Suitable for separate temperature measurement
and temperature compensation in the process.
Length L:
120 mm
Shaft diameter:
12 mm
Temperature range:
- 30 ... +135 °C
Connection:
screw plug head with Pg 13.5
You will find combined sensors with integrated
temperature probe in the respective chapters.
Supply (except HD):
washer 9980/52
O-ring type 9932/07
Supply (HD version):
HD sealing type 9980/51
Connecting cable (design A, B, F, G):
2-pole: e.g. type 9907/05
(length 5 m with free end)
4-pole: e.g. type 9909/15
(length 5 m with free end)
SMEK: e.g. type SMEK 20/05
(length 5 m with free end)
For additional connecting cables, see under
Accessories.
30
sensor Pt 100
sensor Pt 1000
pressure range [bar] 10 10 10
shaft material stainless steel 1.4571
DURAN®
design corresponding illustration A B A
Resistance thermometers with fixed cable
9010
/25
9010
/85
9011
/25
Resistance thermometers with fixed cable
Suitable for separate temperature measurement and
temperature compensation in the process.
Length L:
120 mm
Shaft diameter:
12 mm
Temperature range:
- 30 ... +135 °C
Connection:
5 m fixed cable, flange cap
Supply:
O-ring type 9932/07
pressure screw type 9980/55-14 has to be
ordered separately
A 9010/259011/25
B 9010/85
L
31
temperature range [°C] 0 ...135
pressure range [bar] 10
shaft material stainless steel 1.4571
Grounding rod
E 16
51
Grounding rod
The grounding rod serves for potential compensa-
tion for measuring in ungrounded liquids.
Length L:
120 mm
Shaft diameter:
12 mm
Connection:
screw plug head with thread Pg 13.5
Supply:
washer 9980/52
O-ring type 9932/07
Connecting cable:
e.g. type 9905/05 (length 5 m with free end)
For additional connecting cables, see under
Accessories.
E 1651
L
32
temperature sensor integrated Pt 1000 Pt 1000
temperature range [°C] - 30 ... +100 -30 ... +100 -30 ... +100 -30 ... +100 -30 ... +135 0 ... 80
cell constant (±10 %) [cm-1] 0.5 1.0 2.0 1.0 1.0 1.0
recommended measuring range (25°C) up to [mS/cm] 2) 100 200 400 200 200 200
pressure range [bar] 10 10 10 10 10 10
platinum electrodes, design 2-flat 2-flat 2-flat 2-flat 2-flat 2-ring
shaft material glass
POM
connection 2-pole 2-pole 2-pole 4-pole SMEK 2-pole
certified pressure and temperature consistency 1)
design corresponding illustration A A A A B C
1) These types are supplied in series with Works Certificate 2.1 according to DIN EN 10204 regarding resistance to pressure and temperature.2) Out of the recommended conductivity range the error of measurement can be >10%, also depending on conductivity meter.
Conductivity cells
LF 1
051
LF 1
101
LF 1
201
LF 1
101T
LF 1
101T
HD
LF 5
101
A LF 1201LF 1051LF 1101LF 1101T
B LF 1101T HD
C LF 5101TLF 5101
D LF 71T
L
Pt 1000 Pt 1000
0 ... 80 -30 ... +100
1.0 1.0
200 2.000
10 10
2-ring 4-ring
4-pole SMEK
C D
LF 5
101T
33
LF 7
1T
Conductivity cells
Robust conductivity cells for on-line measuring.
Cells with glass shaft for high chemical resistance.
Robust cells with plastic shaft.
Length L:
120 mm
Shaft diameter:
12 mm
Connection:
screw plug head with thread Pg 13.5
Supply (except HD):
washer 9980/52
O-ring type 9932/07
Supply (HD version):
HD sealing type 9980/51
Connecting cable:
2-pole: e.g. type 9907/05
(length 5 m with free end)
4-pole: e.g. type 9909/15
(length 5 m with free end)
SMEK: e.g. type SMEK 18/05
(length 5 m with free end)
For additional connecting cables, see under
Accessories.
For additional conductivity measuring cells, see
chapter MultiSens electrodes.