SYMBOLS FOR VALVES & COCKS
VALVES SYMBOLS
SDSL VALVE
SDNR VALVE
NR VALVE
SWING CHECK VALVE
BUTTERFLY VALVE
GATE VALVE
STRUM BOX
MUD BOX
Y-TYPE STRAINER
PIPE CLASSIFICATION
LOW PRESSURE PIPE
MEDIUM PRESSURE PIPE
HIGH PRESSURE PIPE
PIPE TYPES
ERW (ELECTRIC RESISTANCE WELDED) PIPES
MS PIPES
LOW PRESSURE PIPES
SEAMLESS PIPES
MS PIPES
COPPER NICKEL (CuNi) PIPES
COPPER (Cu) PIPES
STAINLESS STEEL PIPES
PIPING COLOUR CODESYSTEM BELT /
BAND
PIPE COLOUR
MARKING
FRESH WATER COOLING SYSTEM
BLUE WHITE
FUEL OIL (DIESEL) BROWN WHITE
LUB OIL YELLOW WHITE
FIRE MAIN & DECKWASH SIGNAL RED
SEA WATER COOLING SYSTEM
GREEN WHITE
FEED WATER ORANGE WHITE
STP SYSTEM BLACK WHITE
PENETRATION PIECES
FLANGE PENETRATION
Applied on watertight bulkhead / deck
SLEEVE PENETRATION
Applied on watertight bulkhead / deck / platform
Sleeve provided with two holes
PIPE TESTING
AIR PRESSURE TESTING
WATER PRESSURE TESTING
HYDRAULIC PRESSURE TESTING
WATER PRESSURE TESTING
TEST PRESSURE = 1.5 * WORKING PRESSURE
OBSERVATION FOR LEAKAGES
WATER PRESSURE TESTING
WATER
TANK
RELIEF V/V
COMPRESSOR
PRESSURE GAUGE
PRESURE COCK
RESERVOIR
RELEASE V/V ISOLATION V/V
PIPE
FRESH WATER GENERATOR
Operating ParametersSEA WATER
Sea water intake = 3000 ltrs/hr
Salt concentration = 36000 ppm
pH range = 7.5 - 7.9
Required pre pressure = 0.5 - 3 bars
Operating Parameters
PURE WATER
Pure water output = 20000 ltrs/day
Salt concentration = 500-750 ppm
pH range = 7.0 - 7.2
Recovery rate = 30 %
FRESH WATER GENERATOR RO PLANT
VACCUM TOILET SYSTEM
MAIN PURPOSE : Receive, treat & discharge sewage
PIPES : MS Galvanized
SEWAGE TRANSPORT BY : (Vaccum) Air
SYSTEM WORKING PRESSURE : 4 Bar
SEWAGE TREATMENT PLANT
RAW
SEWAGE
DISCHARGE V/VBLEACH TANK CHEMICAL FEED PUMP
SEDIMENTATION
TANKS
BACK
WASH
GATE
V/V
FLOW CONTROL V/V
FLOW PUMP
MACERATOR
PUMP
VENT
PRESSURE
SWITCH
SOLENOID
V/V
SURAJ S. POWAR