17
SYMBOLS FOR VALVES & COCKS VALVES SYMBOLS SDSL VALVE SDNR VALVE NR VALVE SWING CHECK VALVE BUTTERFLY VALVE GATE VALVE STRUM BOX MUD BOX Y-TYPE STRAINER

Piping presentation

Embed Size (px)

DESCRIPTION

...

Citation preview

  • SYMBOLS FOR VALVES & COCKS

    VALVES SYMBOLS

    SDSL VALVE

    SDNR VALVE

    NR VALVE

    SWING CHECK VALVE

    BUTTERFLY VALVE

    GATE VALVE

    STRUM BOX

    MUD BOX

    Y-TYPE STRAINER

  • PIPE CLASSIFICATION

    LOW PRESSURE PIPE

    MEDIUM PRESSURE PIPE

    HIGH PRESSURE PIPE

  • PIPE TYPES

    ERW (ELECTRIC RESISTANCE WELDED) PIPES

    MS PIPES

    LOW PRESSURE PIPES

  • SEAMLESS PIPES

    MS PIPES

    COPPER NICKEL (CuNi) PIPES

    COPPER (Cu) PIPES

    STAINLESS STEEL PIPES

  • PIPING COLOUR CODESYSTEM BELT /

    BAND

    PIPE COLOUR

    MARKING

    FRESH WATER COOLING SYSTEM

    BLUE WHITE

    FUEL OIL (DIESEL) BROWN WHITE

    LUB OIL YELLOW WHITE

    FIRE MAIN & DECKWASH SIGNAL RED

    SEA WATER COOLING SYSTEM

    GREEN WHITE

    FEED WATER ORANGE WHITE

    STP SYSTEM BLACK WHITE

  • PENETRATION PIECES

    FLANGE PENETRATION

    Applied on watertight bulkhead / deck

  • SLEEVE PENETRATION

    Applied on watertight bulkhead / deck / platform

    Sleeve provided with two holes

  • PIPE TESTING

    AIR PRESSURE TESTING

    WATER PRESSURE TESTING

    HYDRAULIC PRESSURE TESTING

  • WATER PRESSURE TESTING

    TEST PRESSURE = 1.5 * WORKING PRESSURE

    OBSERVATION FOR LEAKAGES

  • WATER PRESSURE TESTING

    WATER

    TANK

    RELIEF V/V

    COMPRESSOR

    PRESSURE GAUGE

    PRESURE COCK

    RESERVOIR

    RELEASE V/V ISOLATION V/V

    PIPE

  • FRESH WATER GENERATOR

  • Operating ParametersSEA WATER

    Sea water intake = 3000 ltrs/hr

    Salt concentration = 36000 ppm

    pH range = 7.5 - 7.9

    Required pre pressure = 0.5 - 3 bars

  • Operating Parameters

    PURE WATER

    Pure water output = 20000 ltrs/day

    Salt concentration = 500-750 ppm

    pH range = 7.0 - 7.2

    Recovery rate = 30 %

  • FRESH WATER GENERATOR RO PLANT

  • VACCUM TOILET SYSTEM

    MAIN PURPOSE : Receive, treat & discharge sewage

    PIPES : MS Galvanized

    SEWAGE TRANSPORT BY : (Vaccum) Air

    SYSTEM WORKING PRESSURE : 4 Bar

  • SEWAGE TREATMENT PLANT

    RAW

    SEWAGE

    DISCHARGE V/VBLEACH TANK CHEMICAL FEED PUMP

    SEDIMENTATION

    TANKS

    BACK

    WASH

    GATE

    V/V

    FLOW CONTROL V/V

    FLOW PUMP

    MACERATOR

    PUMP

    VENT

    PRESSURE

    SWITCH

    SOLENOID

    V/V

  • SURAJ S. POWAR