Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
POR-FESER EMILIA ROMAGNA 2014-2020 - ASSE 6CITTA’ ATTRATTIVE E PARTECIPATE IN ATTUAZIONE DELL’AGENDA URBANA
PROGETTO ESECUTIVO DI LABORATORIO APERTO NELL’ EX TEATRO VERDIMo.Ve.rdi - Riding, Development, Inspiration
18. OPERE STRUTTURALI - ABACO DEI DETTAGLI COSTRUTTIVI
RESPONSABILE DI PROGETTO
Arch. Elisa Uccellatori
GRUPPO DI PROGETTO
Arch. Massimo DaviArch. Federica PoggiArch. Sergio Fortini
PROGETTAZIONE STRUTTURALE
Ing. Denis Zanetti
PROGETTAZIONE IMPIANTISTICA
Ing. Paolo Magri
RESPONSABILE UNICO DI PROGETTO
Arch. Natascia FrassonDirigente del Servizio Beni Monumentali
DIRIGENTE SETTORE OOPP
Ing. Luca Capozzi
BULLONI non a serraggio controllato SB (EN15048-1): VITE CL.8.8 - DADO CL.10 - ROND. A2FORI NELL'ACCIAIO: DIAMETRO BULLONE + 1 mm (PER BULLONE ≤ 20 mm) + 1,5 mm (PER BULLONE > 20 mm)
fykNORMATIVA DI CALCOLO ADOTTATA
NORMATIVA DI RIFERIMENTO : - DM 14.01.2008 " APPROVAZIONE DELLE NUOVE NORME TECNICHE PER LE COSTRUZIONI- CIRCOLARE ESPLICATIVA N° 617 DEL 02.02.2009 AL DM 14.01.2008
ALTRE NORME E DOCUMENTI TECNICI INTEGRATIVI : - UNI EN 1998-4:2006
- UNI EN 1992-1-1:2005- UNI EN 1993-1-1:2005- CNR 2006/2007: ISTRUZIONI PER LA PROGETTAZIONE, L'ESECUZIONE ED
IL CONTROLLO DELLE STRUTTURE IN LEGNO- PROCESSI DI SALDATURA SECONDO EN ISO 4063- ACCETTABILITÀ SALDATURE SECONDO EN ISO 5817- TOLLERANZE DIMENSIONALI SECONDO UNI EN 1090
Ts (Nm)
14161820
242730
22
M.18 ø19.0
M.22 ø23.5
BULLONESIMBOLO FORO
ø25.5
ø21.0
ø17.0ø15.0ø13.0
M.14M.16
M.12
M.20
M.24
ø28.5M.27
M.30 ø31.5
SIMBOLO DI ORIENTAMENTO
COMPOSIZIONE BULLONE
n°1 VITE
CL.1
0.9
CL.6
.8n°1 ROND.n°1 DADO
ISO4014 (6.8)
ISO7089 (A2)ISO4032 (8)
n°1 VITE
n°2 ROND.n°1 DADO
ISO4014 (8.8)
ISO7089 (A2)ISO4032 (10)
n°1 VITE
n°2 ROND.n°1 DADO
ISO4014(10.9)
ISO7089 (A4)ISO4032 (12)
CL.8
.8M
TABELLE SERRAGGIO BULLONI
128.8 10.990 113144 180225 281309 387439 549597 747759 9491110 13881508 1885
X
ø11.0M.10
PRESCRIZIONI SUI MATERIALI AD USO STRUTTURALE
- ACCIAIO PER PROFILI LAMINATI A CALDO E PIASTRE: tipo S275 JR CONFORME D.M. 14.01.2008 E UNI EN 10025-2
t ≤ 40 mm. fyk 275 N/mmq.ftk 430 N/mmq.
40 mm. ≤ t < 80 mm. fyk 255 N/mmq.ftk 410 N/mmq.
IN ZONA SISMICA SOVRARESISTENZA rd (= fym ) ≤ 1.20
BULLONI non a serraggio controllato SB (EN15048-1): VITE CL.8.8 - DADO CL.10 - ROND. A2
- CALCESTRUZZO : CLASSE 25/30 - Rck ≥ 30 N/mmqXC1Slump S4Diametro inerti < 30 mm
- ACCIAIO PER CEMENTO ARMATO B450C (EX FeB44K) :TENSIONE CARATTERISTICA DI SNERVAMENTO ≥ fy nom. 450 N/mm.TENSIONE CARATTERISTICA DI ROTTURA ≥ ft nom. 540 N/mm.1.15 ≤ (ft/fy) k ≤ 1.35ALLUNGAMENTO (Agt) k ≥ 7.5 %P
- LEGNO LAMELLARE: classe GL24
- MURATURA IN BLOCCHI: MURATURA IN BLOCCHI DI LATERIZIO ALVEOLATO PORTANTE IN ZONA SISMICAPERCENTUALE DI FORATURA <45%CARTELLE DI LATERIZIO INTERNE DISPOSTE PARALLELAMENTE AL PIANO DEL MURORESISTENZA CARATTERISTICA Fbk≥ 5MPaRESISTENZA CARATTERISTICA A ROTTURA IN DIREZIONE PERPENDICOLARE A QUELLA PORTANTE Fbk≥ 1.5MPa
- ANCORANTE CHIMICO: PER INGHISAGGI DI BARRE SI PRESCRIVE UTILIZZO DI ANCORANTE CHIMICO TIPO HILT HY200 SISMICO
- TRATTAMENTI PROTETTIVI: DA PREVEDERE ALMENO 2 MANI DI ANTIRUGGINE
- MALTA DA INGHISAGGIO: MALTA CEMENTIZIA ESPANSIVA, APPLICABILE MEDIANTE COLAGGIO PER SPESSORI CENTIMETRICI.UNI 8993 E UNI 8994 CIRCA LE CLASSI DI CONSISTENZA PER I TIPI SUPERFLUIDO, FLUIDO E PLASTICO; UNI 8994 E UNI 8996, UNI 8147 PER L’ESPANSIONE SIA IN FASE PLASTICA CHE INDURITA; UNI 8998, CIRCA L’ASSENZA DI BLEEDINGPRINCIPALI CARATTERISTICHE PRESTAZIONALID ELLA MALTA:
Bleeding, UNI 8998 - Assente Caratteristiche espansive: in fase plastica, UNI 8996 > 0.3 %
contrastata UNI 8147 a 24 ore > 0.03 % Adesione al calcestruzzo, UNI EN 12615 (per taglio) > 6 MPa Resistenza allo sfilamento delle barre d’acciaio, RILEM-CEB-FIP RC6-78 > 30 MPa
NOTE GENERALI:
- TUTTE LE MISURE DOVRANNO ESSERE VERIFICATE DALL'IMPRESA CHE PROVVEDERA' ALTRESI' ALLA REDAZIONE DEGLI ELABORATI D'OFFICINA- I DETTAGLI DEI PACCHETTI E DELLE SOLUZIONI NON STRUTTURALI SONO DA DESUMERE DAGLI ELABORATI ARCHITETTONICI- SI RACCOMANDA DI VERIFICARE CON GLI ELABORATI ARCHITETTONICI LE QUOTE DEGLI IMPALCATI A FINITURE ULTIMATE- TUTTI I MATERIALI PER USO STRUTTURALE DEVONO ESSERE IDENTIFICATI E QUALIFICATI SOTTO LA RESPONSABILITA' DEL PRODUTTORE ED ACCETTATI DAL D.L. IN CONFORMITA' A QUANTO PRESCRITTO AL CAPITOLO 11 DEL D.M. 14.01.2008
SE01 - NOTE GENERALIE PRESCRIZIONI MATERIALI
NOTA:
- PER I PASSAGGI IMPIANTISTICI ATTRAVERSO I SOLAI SI PRESCRIVE DI FORARE IL SOLAIO IN CORRISPONDENZA DELL'ALLEGGERIMENTO IN LATERIZIO O POLISTIROLO CON SUPERVISIONE DELLA D.L. STRUTTURALE
- PER I PASSAGGI IMPIANTISTICI ATTRAVERSO LE PARETI PORTANTI IN MURATURA SI RIMANDA A PARTICOLARE IN TAV. SE03.
Classi di importanza
Categorie di servizio
Categoria diproduzione
PC1
PC2
EXC1 EXC2 EXC2 EXC3 EXC3 EXC3
EXC2 EXC2 EXC2 EXC3 EXC3 EXC4
CC1 CC2 CC3
SC1 SC2 SC1 SC2 SC1 SC2
* SE LA CLASSE DI ESECUZIONE NON è SPECIFICATA APPLICARE LA EXC2
CLASSE DI ESECUZIONE *
PARTICOLARI PRESCRIZIONI PER ACCIAIO PER PROFILI LAMINATI A COLADO E PIASTRE
s1 z1
s1 < s2a1= s1z1=1.4xs1
a2=0.4x s1z2=0.6x s1
Cordone singolo
s2
z2
a
z2
a2
a1
s1 z
Cordone doppio
s2
aa
a
s1 < s2a=0.7xs1z=s1
z1 z
• SALDATURE DA EFFETTUARSI IN OFFICINA, CON CONTROLLO DELLE INTEGRITÁ DELLE STESSE E CERTIFICAZIONE DI CORRETTA ESECUZIONE A REGOLA D'ARTE SECONDO LE PRESCRIZIONI DI NORMATIVA, PREVIA PREPARAZIONE DEI LEMBI
• SALDATURE DA EFFETTUARSI SECONDO PROCEDURE QUALIFICATE UTILIZZANDO LE SPECIFICHE PROCEDURE DI SALDATURA (WPS)
• CRITERI DI ACCETTAZIONE MINIMI (secondo EN ISO 5817): EXC1 livello di qualità DEXC2 livello di qualità CEXC3 livello di qualità BEXC4 livello di qualità B+
• LO SPESSORE DI SALDATURA DEVE ESSERE MAGGIORE O UGUALE AL MINIMO SPESSORE DEI COMPONENTI SALDATI DOVE NON DIFFERENTEMENTE INDICATO
SALDATURE
REQUISITI DI ACCETTAZIONE DEI MATERIALI METALLICI PER PROFILI LAMINATI
- TUTTI I PRODOTTI DI CARPENTERIA METALLICA COPERTI DALLA EN 1090-1, DEVONO POSSEDERE MARCATURA CE E DEVONO ESSERE ACCOMPAGNATI DALLA RELATIVA DICHIARAZIONE DI PRESTAZIONE (DoP)
- LA DICHIARAZIONE DI PRESTAZIONE DEVE ESSERE ACCOMPAGNATA DAL CERTIFICATO DI CONTROLLO DELLA PRODUZIONE IN FABBRICA (FCP)
- L'IMPRESA DEVE FORNIRE: - LE SPECIFICHE DEL PROCEDIMENTO DI SALDATURA DEL COSTRUTTURE (WPS) SECONDO LA UNI EN ISO 15609-1
- IL CERTIFICATO DI APPROVAZIONE DELLE PROCEDURE DI SALDATURA (WPQR)SECONDO LA UNI EN ISO 15614-1
- I PATENTINI DI QUALIFICA DEI SALDATORI SECONDO LA UNI EN ISO 9606-1
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
ELA
BO
RAT
O G
RA
FIC
O :
NO
TE G
EN
ER
ALI
E P
RE
SC
RIZ
ION
I MAT
ER
IALI
DAT
A :
SE
TTE
MB
RE
201
6TA
VOLA
: S
E01
SC
ALA
:
3 IPE
270
3 IPE270
2200
APER
TURA
NET
TA
1000APERTURA NETTA
1000
300
BARRE FILETTATEM14/400 INGHISATE NELLA
MURATURA CON RESINA
BULLONI DI COLLEGAMENTOM14/400
CORDOLO IN C.A. 505x3004 16 CON STAFFE 8/10
QUOTA AL GREZZO PLATEA
BULLONI DI COLLEGAMENTOM14/400
BARRE FILETTATEM14/200 INGHISATE SFALSATE NELLAMURATURA CON RESINA
270 300270300
2470
2140
2140
CORDOLO IN C.A. 505x300 3 IPE270
270 1000 270
2 IPE220
3 IPE
270
BARRE FILETTATEM14/400 INGHISATE NELLA
MURATURA CON RESINA
BULLONI DI COLLEGAMENTOM14/400
2 IPE
200
2 IPE
200
2250
APER
TURA
NET
TA
2100APERTURA NETTA
CORDOLO IN C.A. 300x3004 16 CON STAFFE 8/10 300 200 2100 200 300
270
2470
220
300
QUOTA AL GREZZO PLATEA
QUOTA AL GREZZO INGRESSO
HEA 140ESISTENTE
2 IPE
200
2 IPE220
300
300
3100
3100
BULLONI DI COLLEGAMENTOM14/400
BARRE FILETTATEM14/200 INGHISATE SFALSATE NELLAMURATURA CON RESINA
APERTURA TIPO 1PORTALE METALLICO
VISTASCALA 1:20
SEZIONE 1-1SCALA 1:20
APERTURA TIPO 2PORTALE METALLICO
VISTASCALA 1:20
SEZIONE 2-2SCALA 1:20
A2-20mm SCAL PLOT 1=20
A2-20mm
PART.2
PART.1
M14/400
PART.4
PART.3
10
CORDONI DI SALDATURAL=100 PASSO 400
300 QUOTA AL GREZZO INGRESSO
505
3 IPE270
3 IPE
270
CORDONI DI SALDATURAL=100 PASSO 400
10
SEZIONE 3-3SCALA 1:20
NOTA :PER I PARTICOLARI RELATIVI ALLACONNESSIONE COLONNA - TRAVEVEDERE TAVOLA SE03
3 IPE
270
3 IPE270
2200
APER
TURA
NET
TA
1300APERTURA NETTA
1300
300
BARRE FILETTATEM14/400 INGHISATE NELLA
MURATURA CON RESINA
BULLONI DI COLLEGAMENTOM14/400
CORDOLO IN C.A. 505x3004 16 CON STAFFE 8/10
QUOTA AL GREZZO
BULLONI DI COLLEGAMENTOM14/400
BARRE FILETTATEM14/200 INGHISATE SFALSATE NELLAMURATURA CON RESINA
270 300270300
2470
2440
2140
3 IPE
270
270
APERTURA TIPO 3PORTALE METALLICO
VISTASCALA 1:20
PART.2
PART.1
SE02 - CERCHIATURE METALLICHEVISTE E SEZIONI
PUNTELLARESTRUTTUREESISTENTI
PUNTELLARESTRUTTUREESISTENTI
INSERIMENTO DI BIETTE METALLICHE INSERIMENTO DI BIETTE METALLICHE
INSERIMENTO DI BIETTE METALLICHE
PROCEDURA TIPICA PER INSERIMENTO PORTALI :
1 - DEMOLIZIONE IN BRECCIA DELLA MURATURA PER INSERIMENTO ARCHITRAVATURA ORIZZONTALE INTERNA.2 - DEMOLIZIONE IN BRECCIA MURATURE VERTICALI ED INSERIMENTO PIEDRITTI.3 - MESSA IN SPINTA DEI PIEDRITTI.4 - INSERIMENTO BIETTE DI COAZIONE IN ACCIAIO A SP. VARIABILE CHIUSE A FORZA.5 - INGHISAGGI DEI PERNI VERTICALI.6 - PROCEDERE DA 1 A 5 SUL LATO OPPOSTO.7 - INGHISAGGIO DI BASE.
505
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
ELA
BO
RAT
O G
RA
FIC
O :
CE
RH
IATU
RE
ME
TALL
ICH
E V
ISTE
E S
EZI
ON
ITA
VOLA
: S
E02
SC
ALA
: 1:
20D
ATA
: S
ETT
EM
BR
E 2
016
505
300
SEZIONE A-ASCALA 1:10
4 16
L=1550
240
440
STAFFE 8/10300
300
SEZIONE B-BSCALA 1:10
4 16
L=1150
240
240
STAFFE 8/10
A2-20mm SCAL PLOT 1=20A2-20mm
270
90 87.5 87.5 90 50
405
5085
50
35 100
505
185
135
185
5085
5045
4545
PARTICOLARE 1SCALA 1:10
IPE270 PIASTRA 10
10 IN OPERA
M16 CON PIATTO 50X50X5PER TERMINALE A MARTELLO
135
135
IPE270
IPE270
9014011550
395
135
IPE270
PARTICOLARE 2SCALA 1:10
PIASTRA 10
10 IN OPERAM16
IPE270
200
90 87.5 107.5 50
335
5050
5050
300
35 100
150
150
100
PARTICOLARE 3SCALA 1:10
M16 CON PIATTO 50X50X5PER TERMINALE A MARTELLO
PIASTRA 10
10 IN OPERA
35100
110
110
200
IPE200
IPE200
3369
6669
6669
33
8510010050
5511
055
M16
SE03 - CERCHIATURE METALLICHEPARTICOLARI
PARTICOLARE 4SCALA 1:10
PARTICOLARE CERCHIATURA MURATURE ESISTENTI PER PASSAGGIO IMPIANTISCALA 1:10
PARETE ESISTENTEIN MURATURA A 2 TESTE
CERCHIATURA UPN120
BARRE 14/150 mm. INGHISATENELLA MURATURA ESISTENTE
3010
IPE270
35 270 100
SEZIONE C-CSCALA 1:10
3010
IPE200
35
SEZIONE D-DSCALA 1:10
IPE200
IPE200
200 100
509087.587.590 50107.587.590
900
300
150
150
PARETE ESISTENTEIN MURATURA A 2 TESTE
UPN120
M16 M16
PIASTRA 10 PIASTRA 10
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
ELA
BO
RAT
O G
RA
FIC
O :
CE
RC
HIA
TUR
E M
ETA
LLIC
HE
PA
RTI
CO
LAR
ITA
VOLA
: S
E03
SC
ALA
: 1:
10D
ATA
: S
ETT
EM
BR
E 2
016
PROFILO ANGOLARE 100x100INGHISATO CON M14/200
GETTO INTEGRATIVO IN CLS
RETE ELS 8/200x200
LAMIERA GRECATATIPO HI BOND A55/P770
INGHISAGGI 10/400
TRAVE IN SPESSORE ESISTENTE
SOLAIO IN LATEROCEMENTO 200+40mm
HEA
140
ESIS
TENT
E
PART.A
4555
240
RETE 6/100x100INGHISAGGI 10/400
GETTO COLLABORANTE
LAMIERA GRECATA
ANGOLARE 100x100x10
INGHISAGGIO PROFILO M14/200
PROFILO ANGOLARE DI CHIUSURA E SOSTEGNO GRECATA 100x100x5
CHIUSURA CON GRECATA
TRAVE IN SPESSORE ESISTENTE
CHIUSURA CAVEDIO 1PRIMO SOLAIO
PART.ASCALA 1:10
PIANTASCALA 1:20
MODIFICA DIMENSIONE VANO ASCENSORE IN MURATURA
PIANTASCALA 1:20
A2-20mm SCAL PLOT 1=20A2-20mm
SE04 - CHIUSURA CAVEDIE FORI SOLAI
2331
1847
200
NUOVA PARETE INBLOCCHI DI LATERIZIOsp.20 cm.
BARRE 14 INGHISATENELLA MURATURA ESISTENTE(n.3/mq.)
NOTA :SI RACCOMANDA DI VERIFICARELE DIMENSIONE INTERNE DELVANO CON IL FORNITORE DEL MONTAPERSONE
CHIUSURA CAVEDIO IN COPERTURA
1 10/40 L.=10+20 cm.SALDATO AL PROFILO
200
100
4555
SEZIONE 1-1SCALA 1:10
200
HEA140
EVENTUALE APPOGGIO
1 10/40 L.=10-20 cm.SALDATO AL PROFILO
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
B
C
C
C
A
A B
C
ELA
BO
RAT
O G
RA
FIC
O :
CH
IUS
UR
A C
AVE
DI E
FO
RI S
OLA
ITA
VOLA
: S
E04
SC
ALA
: 1:
10 -
1:20
DAT
A :
SE
TTE
MB
RE
201
6
A2-20mm SCAL PLOT 1=20
A2-20mm
SE05 - CHIUSURA CAVEDIE FORI SOLAI
PIANTASCALA 1:50
CHIUSURA VANO C.T.
HEA
200
ESIS
TENT
E
HEA
200
ESIS
TENT
EHEA 140 ESISTENTE
HEA 140
GETTO IN CLSESISTENTE
LAMIERA GRECATAESISTENTE
HEA 140
2800
1900
CONNETTORE A PIOLO12/200
BOTOLA1200
900
NUOVA LAMIERAGRECATA (*)
NUOVO GETTO IN CLSCON RETE ELETTROSALDATA (*)
SEZIONE 1-1SCALA 1:10
HEA 140
HEA200ESISTENTE
5040
4357
55
PIATTO sp.10 mm.SALDATO IN OPERA
PIANO PRIMOCHIUSURA n.3 APERTURE SOLAIO
quote in mm. quote in mm.
1
2 32000
1800
1650
100010006001000
1650
CHIUSURA APERTURE SOLAIO (TIPICO)SCALA 1:20
NUOVO GETTODI COMPLETAMENTO
INGHISAGGI 10/400L=250 mm.
SOLAIO PREDALLESh=4+12+5 ESISTENTE
INGHISAGGI 10/400L=250 mm.
NUOVO GETTODI COMPLETAMENTOCON RETE ELETTROSALDATA
6/20X20
NOTA(*) ALTEZZA LAMIERA GRECATA E GETTO DA VERIFICARE CON ESISTENTE
DEMOLIZIONE DI10 cm. DI CLS PERAPPOGGIO NUOVAGRECATA
120
480
1 20
200
2 00
200 20010
0
150
PANNELLI DIALLEGGERIMENTOIN POLISTIROLO H.=12 cm.
SEZIONE 2-2SCALA 1:10
4012
040
200
PANNELLI DIALLEGGERIMENTO
IN POLISTIROLOH.=12 cm.
120
RETE ELETTROSALDATA6/20X20
PIOLI NELSON
PIOLI NELSON
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
05 S
CA
LA :
1:20
- 1:
10E
LAB
OR
ATO
GR
AFI
CO
: C
HIU
SU
RA
CAV
ED
I E F
OR
I SO
LAI
DAT
A :
SE
TTE
MB
RE
201
6
B
A
B
A
A2-20mm SCAL PLOT 1=20
A2-20mm
NOTA :SI PRESCRIVE LAMIERA GRECATATIPO HI-BOND A55 P770 DISPESSORE 0.7 mm.
1Ø10/20 SUP.1Ø10/20 INF.
1200
2000
SOLAIO PREDALLESH.=16+4 cm.
3+3 16 INF. + SUP.LUNGO IL PERIMETRO
PARETE IN MURATURA A TRE TESTESU VIA CAMALEONTE
FORO ESISTENTESU SOLAIO
PIANTA STATO DI FATTOSCALA 1:20
1Ø10/20 SUP.1Ø10/20 INF.
1200
2000
3+3 16 INF. + SUP.LUNGO IL PERIMETRO
PARETE IN MURATURA A TRE TESTESU VIA CAMALEONTE
PIANTA PROGETTOSCALA 1:20
650
650
LAMIERA GRECATA H55TIPO HI-BOND A55/P770
CHIUSINO DI ISPEZIONEVASCA ANTINCENDIO
M12/20
PRESSOPIEGATO 125x80x10
PROFILO DI APPOGGIOL80x80x10
FINITURA QUOTA FINITO +0.21 m.(+10 cm. DA STATO DI FATTO)
GETTO C.L.S.COLLABORANTE6 cm.
RETE 8 MAGLIA 20x20 cm.
M12/25
SEZIONE A-ASCALA 1:10
200
6055
115
1 10/40 RETE ELETTROSALDATA 8 MAGLIA 20x20 cm.GETTO IN C.L.S. COLLABORANTE 6 cm.
LAMIERA GRECATA H55TIPO HI-BOND A55/P770
M12/25ANGOLARE L80x80x10
SEZIONE B-BSCALA 1:10
200
1 10/40RETE ELETTROSALDATA 8 MAGLIA 20x20 cm.GETTO IN C.L.S. COLLABORANTE 6 cm.
PRESSOPIEGATO 125x80x10 M12/25ANGOLARE L80x80x10
LAMIERA GRECATA H55TIPO HI-BOND A55/P770
ANGOLARE L60x60x6APPOGGIO PIASTRA DI
CHIUSURA CHIUSINO
M12/20
200
6055
115
RETE ELETTROSALDATA 8 MAGLIA 20x20 cm.GETTO IN C.L.S. COLLABORANTE 6 cm.
LAMIERA GRECATA H55TIPO HI-BOND A55/P770
100
SEZIONE C-CPARTICOLARE FINITURA CHIUSINOSCALA 1:10
650
+0.21 P. FINITO
SE06 - CHIUSURA VASCA ANTINCENDIO
CHIUSURA VASCA ANTINCENDIO
SOLAIO PREDALLESH.=16+4 cm.
BOTOLA DA DEFINIRE CON LA D.L.FINITURA SUPERFICIALE CONFORMEA PAVIMENTO
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
06 S
CA
LA :
1:20
- 1:
10E
LAB
OR
ATO
GR
AFI
CO
: C
HIU
SU
RA
VA
SC
A A
NTI
NC
EN
DIO
DAT
A :
SE
TTE
MB
RE
201
6
INTERVENTO SULLA COPERTURA DELLA PLATEA
PART.A
PIANTA COPERTURASCALA 1:100
A2-20mm SCAL PLOT 1=20A2-20mm
PARTICOLARE ASCALA 1:5
80
2 L80x80x8
2M16
PIATTO 72x72x8SALDATO IN OPERAAD ANGOLARE
SEZIONE 2-2SCALA 1:5
8080 8 80
2M16
SE07 - NUOVI ROMPITRATTAIN COPERTURA
NOTA• STRUTTURA RETICOLARE METALLICA ESISTENTE• SI PRESCRIVE DI PROTEGGERE CON ZINCATURA A FREDDO,
DOPO L'INSTALLAZIONE DEI NUOVI PROFILI, I PUNTI DI CONTATTO CON LA STRUTTURA ESISTENTE
• PER QUANTO RIGUARDA I PARTICOLARI RELATIVI AI NUOVI PANNELLI DI COPERTURA SI RIMANDA AGLI ELABORATI ARCHITETTONICI DI PROGETTO
DOPPIO ANGOLAREESISTENTE
DOPPIO ANGOLARE ESISTENTE
DOPPIO ANGOLAREESISTENTE
SALDATURA IN OPERA
SEZIONE 1-1SCALA 1:5
SALDATURA IN OPERA
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
07 S
CA
LA :
1:10
0 - 1
:5E
LAB
OR
ATO
GR
AFI
CO
: N
UO
VI R
OM
PIT
RAT
TA IN
CO
PE
RTU
RA
DAT
A :
SE
TTE
MB
RE
201
6
1000
200
500
150
SCALA MARINARA CON PROTEZIONE
NUOVO PARAPETTO PASSERELLA
PROFILI HEA 120
HEA 120
GRIGLIATO 34x38 PIATTO 25x2
CORRENTE 40x20x2
MONTANTE 40x40x4
CORRENTE 40x20x2
PARAPIEDEPIATTO IN ACCIAIO 30/10
40
40
20
40
NUOVA PASSERELLA
STRALCIO SEZIONE TORRE SCENICASCALA 1:50
SEZIONE 3-3SCALA 1:10
305
440
114
1139
A2-20mm SCAL PLOT 1=20A2-20mm
SE08 - PASSERELLA TORRESCENICA
PART.1
25012
5
4085
125
125 125
40858540
PART. 1SCALA 1:10
PART.2
MONTANTE 40x40x4
HEA 120
PART. 2SCALA 1:5
PIATTOsp.10 mm.
120
4040
40
70
SALDATURE 10
800
n.3+3 M20
n.3+3 M20
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
08 S
CA
LA :
1:50
- 1:
10E
LAB
OR
ATO
GR
AFI
CO
: PA
SS
ER
ELL
A T
OR
RE
SC
EN
ICA
DAT
A :
SE
TTE
MB
RE
201
6
2500
100
2400
SBARCO SCALA
BARACCATURA DI COPERTURA PIANTASCALA 1:20
1350
1460
A2-20mm SCAL PLOT 1=20A2-20mm
NOTA :PRIMA DI PRODURRE I PROFILI E' NECESSARIO VERIFICAREIN SITO LE DIMENSIONI AVENDO CURA DI PULIRE LA SUPERFICIE DI BASE DI APPOGGIO DEI MONTANTI
*
*
PARETE IN BLOCCOCASSERO
PART.2
PARETE IN MURATURA
500
CORDOLO IN C.A.
PARETE IN BLOCCO CASSERO
800
PART.3 PART.1
MONTANTE TUBOLARE60x60x2 INTERASSE 90 cm.
PANNELLO IN POLICARBONATODI CHIUSURA SP.=40 mm.
SCOSSALINA DI TESTATA
CORRENTE TUBOLAREDI CHIUSURA 60x60x2
TUBOLARE 60x60x2INTERASSE MAX 90 cm.
PANNELLO DI COPERTURAH.=100 mm.
ANGOLARE L60x60x6
PROSPETTOSCALA 1:20
PANNELLO IN POLICARBONATODI CHIUSURA SP.=40 mm.
SCOSSALINA DI TESTATA
CORRENTE TUBOLARE DICHIUSURA 60x60x2
MONTANTE TUBOLARE60x60x2INTERASSE 90 cm.
900 900
PARTICOLARE 1SCALA 1:5
60
60
TUBOLARE 60x60x2
N° 1 BULLONE M16
MONCONE 50x50x3L.=50 mm. SALDATOA TUBOLARE CORRENTE
MONCONE 50x50x3L.=50 mm. SALDATOA TUBOLARE CORRENTE
N° 1 BULLONE M16MONTANTE 60x60x2
PARTICOLARE 2SCALA 1:5
6060
120
3060
30
30 120 30
60 60 60
180
TASSELLO M16INGHISATO CON RESINATIPO HILTI HY200
SALDATURE IN OFFICINA5
5
PARTICOLARE 3SCALA 1:5
100
60
CORDONE DI SALDATURA IN OPERA
ANGOLARE 60x60x6
PANNELLO DI CHIUSURA H.=100
IMPERMEABILIZZAZIONEDA VERIFICARE CON LA D.L.
TASSELLO M14/40 CONANCORAGGIO CHIMICOTIPO HILTI HY200
2%
SE09 - BARACCATURA IN COPERTURA
4a 1a2a3a5a6a7a8a9a
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
09 S
CA
LA :
1:20
- 1:
10E
LAB
OR
ATO
GR
AFI
CO
: B
AR
AC
CAT
UR
A IN
CO
PE
RTU
RA
DAT
A :
SE
TTE
MB
RE
201
6
SE10 - INQUADRAMENTO NUOVESTRUTTURE METALLICHE ZONA BLACK BOX
STRUTTURA "A" - SCALA DI EMERGENZATAVOLE SE11 - SE12 - SE13
STRUTTURA "B" - FRONTE BLACK BOXTAVOLE SE14 - SE15 - SE16
INQUADRAMENTO GENERALE
GIUNTO STRUTTURALE
A B C D
12
3
1
1'
E E E
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
10 S
CA
LA :
ELA
BO
RAT
O G
RA
FIC
O :
INQ
UA
DR
AM
EN
TO N
UO
VE S
TRU
TTU
RE
ME
TALL
ICH
ED
ATA
: S
ETT
EM
BR
E 2
016
1
2
3
4
5
6
7
8
9
10
1112
13
14
15
16
17
18
19
20
21
22
2324
HEA2
00
HEA2
00
HEA2
00
HEA1
20
IPE160 IPE160
12345678910111213
14 15 16
PIANTA A q=+0.60 m.Scala 1:25
+0.40
+0.40
+2.26
13 a
lzate
x 1
69.2
= 2
200
mm
.11
alza
te x
169
.2 =
186
1 m
m.
A B C D
A B C D
12
3
AA
HEA200 HEA200
169
1315
SEZIONE A-AScala 1:25
IPE160
B
B
UPN220
UPN220
2690
8011
0080
170
8011
0080
12 pedate x 300 = 3600 mm.
UPN220
UPN220UPN220
UPN220
5020
8120
30+0.13
3577 825 964
IPE160
-1.80 q.p.f.
-1.90
5030
050
50 300 50
400
400
-1.90
-1.80 q.p.f.
1090
-1.90
-1.80 q.p.f.
SALDATURADA REALIZZAREIN OPERA
500
5040
050
400
50 300 50
9540
5
SALDATURADA REALIZZAREIN OPERA
1
PART. PIASTRA DI BASE HEA200/UPN220Scala 1:10
Lmin 3
50
3'
1'
E
1090
Lmin 3
50
5030
050
50 200 50
400
400
-1.90
-1.80 q.p.f.
1090
PART. PIASTRA DI BASE HEA200 (FILO )Scala 1:10
Lmin 3
50
100
1C
PART. PIASTRA DI BASE HEA200 (FILO )Scala 1:10
1A
SE11 - NUOVA SCALA METALLICAVISTE E PARTICOLARI
PIATTIsp.10 mm.
PIATTIsp.10 mm.
340
50
GIUNTOSTRUTTURALE
50
GIUNTOSTRUTTURALE
PER PIASTRE DI BASE COLONNE HEA120 VEDI TAV. SE13
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
1825
160
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
11 S
CA
LA :
1:25
- 1:
10E
LAB
OR
ATO
NU
OVA
SC
ALA
ME
TALL
ICA
VIS
TE E
PA
RTI
CO
LAR
ID
ATA
: S
ETT
EM
BR
E 2
016
+0.40+0.40
HEA2
00
HEA200
1100 80 170 1100 8080 80
2690
2200
-1.80 q.p.f.-1.80 q.p.f.
1305 1385
SEZIONE B-BScala 1:25
2345678910111213
14 15 16
PIANTA A q=+2.26 m.Scala 1:25
A B C D
1
AA
B
B
17 18 19 20 21 22 23 24
1100
+0.40
2690
8011
0080
170
8011
0080
UPN220
UPN220UPN220
UPN220
IPE160
IPE160
IPE160 IPE160
IPE160
IPE1
60
3577 825 964
C
C
D
D
TONDO 20
1
+2.26+2.26
HEA2
00HEA200
4061
-1.80-1.80
1305 1365
SEZIONE C-CScala 1:25
1100
1100
2670
IPE160
IPE160
1100
SEZIONE D-DScala 1:25
+2.26+2.26
1238
HEA1
20
HEA1
20-1.80-1.80
+0.13+0.13
4161
-1.90-1.90 -1.90-1.90 -1.90-1.90
SE12 - NUOVA SCALA METALLICAVISTE E PARTICOLARI
E
2
3
1
3'
1'
169
1113
340
2690
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
PART.2
PART.1
PART.1
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
12 S
CA
LA :
1:25
ELA
BO
RAT
O G
RA
FIC
O :
NU
OVA
SC
ALA
ME
TALL
ICA
VIS
TE E
PAT
ICO
LAR
ID
ATA
: S
ETT
EM
BR
E 2
016
390
50 110 70 110 50
200
5010
050
HEA2
00
HEA2
00
39080 20
1020
80
8020
10
10 10 10 10
HEA200
100
PIATTOsp.10 mm.
10PIATTOsp.10 mm.
PIATTOsp.10 mm.
UPN200COSCIALISCALA
L80x8L80x8200
L80x8
UPN220
IPE160
50
6040
90
PART. 1Scala 1:10
-1.90-1.90
-1.80 q.p.f.-1.80 q.p.f.
PART. PIASTRA DI BASE HEA120 (FILO )Scala 1:10
4017
040
40 170 40
250
250
50
HEA2
00
390
50 110 70 110 50
300
5010
015
0
HEA2
00
HEA200
UPN220
300
390
TONDO 20TONDO 20
IPE1
60
1010
220
6080
50
15040 70 40
30
UPN220COSCIALESCALA
PIATTO390x300x10 mm.
100100
100 100
10 10 50 50
6040
6030
IPE160
4
PART. 2Scala 1:10
UPN2
20
HEA200
1
1
4
VISTA 4-4
3 3
VISTA 2-2
VISTA 3-3
1090
Lmin 3
50
PIATTIsp.10 mm.
-1.90-1.90
-1.80 q.p.f.-1.80 q.p.f.
4012
040
40 170 40
250
250
1090
Lmin 3
50
PIATTIsp.10 mm.
50
PART. PIASTRA DI BASE HEA120 (FILO )Scala 1:10
2D
220 190
TONDO 20
SE13 - NUOVA SCALA METALLICAPARTICOLARI
PART. PARAPETTOScala 1:10
TUBO60.3/2.9
TUBO60.3/2.9
TUBO26.9/2
1100
500
UPN220
2565
6525
55 25PIATTOsp.8 mm.
D 3
VERIFICAREQUOTA ESIST.
2 2
VISTA 2-2
VISTA 1-1
2
2
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
13 S
CA
LA :
1:1
0E
LAB
OR
ATO
GR
AFI
CO
: N
UO
VA S
CA
LA P
AR
TIC
OLA
RI
DAT
A :
SE
TTE
MB
RE
201
6
E F GPIANTA PIASTRE DI BASE q=-1,90 m.Scala 1:25
4082 2103
PIANTA PIANO A q=+2,115 m. p.s.f. - PIANO DI SBARCO BLACKBOX (q=+2,26 p.f.)Scala 1:25
1'
2
33'
1156
HEA200
HEA200
HEA120
HEA120
D
1825
HEA200 HEA200
HEA200 HEA200
E F G4082 2103
1'
2
33'
1156
D
1825
IPE200
IPE200
IPE200
IPE2
00
IPE2
00
IPE2
00
PIANTA PIANO A q=+4,24 m. p.s.f.Scala 1:25E F G
4082 2103
1'
3
1825
IPE1
60
IPE1
60
IPE1
60
IPE160
IPE160
IPE160
5030
050
50 300 50
400
400
-1.90
-1.80 q.p.f.
1090
Lmin 3
50
PART. PIASTRA DI BASE HEA200Scala 1:10
PIATTIsp.10 mm.
SE14A - NUOVO VANO ASCENSOREPIANTE E PARTICOLARI
INQUADRAMENTO GENERALE
VERIFICAREQUOTA ESIST.
TRAVETTI IN LEGNO8x12 cm.
INTERASSE max 80 cm.
BLACK BOX
TRAVETTI IN LEGNO 16x24 cm.INTERASSE max 80 cm.
PART.1 - GIUNTO STRUTTURALE CON BLACKBOXScala 1:10
+2,26
+2,115 p.s.f.
CARPLYsp.25 mm.
TRAVETTI INLEGNO 8x12 cm.
IPE200
PIATTO 100x100 sp.5 mm.SALDATO ALLA TRAVE
TRAVETTI INLEGNO 16x24 cm.
i=80 cm.80
GIUNTOSISMICO
SELLA IN PRESSOPIEGATO150x100 sp.6 mm.i=80 cm.
PART.1
161
161
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
14 S
CA
LA :
1:2
5 - 1
:10
ELA
BO
RAT
O G
RA
FIC
O :
NU
OVO
VA
NO
AS
CE
NS
OR
E P
IAN
TE E
PA
RTI
CO
LAR
ID
ATA
: S
ETT
EM
BR
E 2
016
PIANTA PIANO A q=+5,50 m. p.s.f.Scala 1:25E F G
4083 2103
1'
3
1825
IPE1
60
IPE1
60
IPE1
60
IPE160
IPE160
PIANTA PIANO A q=+9,28 m. p.s.f.Scala 1:25E F G
4083 2103
1'
3
1825
IPE1
60
IPE1
60
IPE1
60IPE160
IPE160
5030
050
50 300 50
400
400
-1.90
-1.80 q.p.f.
1090
Lmin 3
50
PART. PIASTRA DI BASE HEA200Scala 1:10
PIATTIsp.10 mm.
SE15A - NUOVO VANO ASCENSOREPIANTE E PARTICOLARI
PIANTA PIANO A q=+6,76 m. p.s.f.Scala 1:25
E F G4083 2103
1'
3
1825
IPE1
60
IPE1
60
IPE1
60
IPE160
IPE160
IPE160
INQUADRAMENTO GENERALE
VERIFICAREQUOTA ESIST.
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
15 S
CA
LA :
1:25
- 1
:10
ELA
BO
RAT
O G
RA
FIC
O :
NU
OVO
VA
NO
AS
CE
NO
RE
PIA
NTE
E P
AR
TIC
OLA
RI
DAT
A :
SE
TTE
MB
RE
201
6
+2.2
6
HEA200
IPE2
00
HEA200
HEA200
+2.1
15 p
.s.f.
IPE1
60IP
E160
IPE1
60
IPE1
60IP
E160
IPE1
60
+4.2
4 p.
s.f.
+5.5
0 p.
s.f.
+6.7
6 p.
s.f.
+9.2
8 p.
s.f.
VIST
A FI
LOSc
ala
1:25
A
4083
2103
EF
G
-1.8
0
-1.9
0
PART
.2
CARP
LYsp
.25
mm
.
TRAV
ETTI
IN L
EGNO
8x12
cm
.IN
TERA
SSE
max
80
cm.
SE16 - NUOVO VANO ASCENSOREVISTA FILO A
VERI
FICA
REQU
OTA
ESIS
T.
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
16 S
CA
LA :
1:2
5E
LAB
OR
ATO
GR
AFI
CO
: N
UO
VA V
AN
O A
SC
EN
OR
E V
ISTA
FIL
O A
DAT
A :
SE
TTE
MB
RE
201
6
1'3
-1.8
0
-1.9
0
IPE2
00
+2.1
15 p
.s.f.
IPE1
60
+4.2
4 p.
s.f.
+5.5
0 p.
s.f.
+6.7
6 p.
s.f.
+8.0
2 p.
s.f.
+9.2
8 p.
s.f.
IPE1
60
IPE1
60
IPE1
60
IPE1
60
IPE1
60
IPE1
60
IPE1
60
IPE1
60
HEA200
HEA200
HEA200
TOND
O 20
TOND
O 20
340
137.5 65 137.5
40 65 40
190
50
PART
. 1Sc
ala
1:10
VIST
A FI
LOSc
ala
1:25
G
1825
IPE1
60
HEA200
PART
.1
PART
. 2Sc
ala
1:10
120
40 40 40
100 60
40
PIAT
TOsp
.10
mm
.
PIAT
TOsp
.10
mm
.
1'3
IPE2
00
+2.1
15 p
.s.f.
IPE1
60
+4.2
4 p.
s.f.
+5.5
0 p.
s.f.
+6.7
6 p.
s.f.
+8.0
2 p.
s.f.
+9.2
8 p.
s.f.
IPE1
60
IPE1
60
IPE1
60
IPE1
60
HEA200
HEA200
VIST
A FI
LOSc
ala
1:25
E
1825
PART
.1
IPE2
00
190819081964
1302 1302 1302107210721260126012601260
1260126012601260
SE17A - NUOVO VANO ASCENSOREVISTA FILI E PARTICOLARIE G
VERI
FICA
REQU
OTA
ESIS
T.
-1.8
0
-1.9
0VE
RIFI
CARE
QUOT
A ES
IST.
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
17 S
CA
LA :
1:2
5 - 1
:10
ELA
BO
RAT
O G
RA
FIC
O :
NU
OVO
VA
NO
AS
CE
NO
RE
VIT
SA
FIL
I E, G
E P
AR
TIC
OLA
RI
DAT
A :
SE
TTE
MB
RE
201
6
TRAVE PRINCIPALE 12x28
TRAVETTO12x14 i=80 max.
SOTTO PILASTRO12x24
SOTTO PILASTRO12x24
TRAVE 12x28PILASTRO PARAPETTO
12x24
+1.55
-0.20
-0.20
-0.20
STRALCIO PIANTASCALA 1:25
PILASTRI12x12
SE18A - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICAPIANTA
NOTA:• PER LE SEZIONI A-A, B-B e C-C SI RIMANDA ALLE TAVOLE
STRUTTURALI SE19, SE20, SE21
SOTTO PILASTRO12x24
SOTTO PILASTRO12x24
SOTTO PILASTRO12x24
PILASTRI12x12
TRAVETTO12x14
GIUNTO STRUTTURALEsp.10 cm.
800
MONTANTI PER PORTADI ACCESSO VANO SOTTOSCALA
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
18 S
CA
LA :
1:2
5E
LAB
OR
ATO
GR
AFI
CO
: S
CA
LIN
ATA
IN L
EG
NO
DI A
CC
ES
SO
ALL
A T
OR
RE
SC
EN
ICA
PIA
NTA
DAT
A :
SE
TTE
MB
RE
201
6
-1.80
-0.80
80 100 80
5050
7070
5050
340
260
2 TASSELLI M16TIPO "HILTI HIT200 CON HIV"
2+2 VITI DA LEGNO
4+4 VITI DA LEGNO
10
10
10
10
8
2+2 TASSELLI M16TIPO "HILTI HIT200 CON HIV"
200
10
8 244 8
150
TRAVE PRINCIPALE 12x28TRAVETTI SECONDARI12x14 i=80 max.
PILASTRO12x24
PILASTRO12x24
TRAVE 12x14
PILASTRO PARAPETTOD'ANGOLO 12x24
TRAVERSO12x12
TRAVERSO12x12
PILASTRO12x24
-0.20
PART.1PART.2
SEZIONE A-ASCALA 1:25
PART. 1SCALA 1:10
PART. 2SCALA 1:10
280
892
30039
2
50 100 50
8 184 8
9610
010
096
TRAVE IN LEGNO 12x28 i=100 cm6+6 VITIDA LEGNO Ø8
7070
7070
8
260
160 92 8
200
3+3 TASSELLI M16TIPO "HILTI HY200-A CON HIT-V"8
8
8 120 8
280
892
TRAVE PRINCIPALE 12x28
6+6 VITIDA LEGNO Ø8
80
~9900
CARPLYsp.25 mm.
SE19A - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICASEZIONE A-A
DIAGONALI DICONTROVENTO12x12 cm.
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
19 S
CA
LA :
1:25
- 1:
10E
LAB
OR
ATO
GR
AFI
CO
: S
CA
LIN
ATA
IN L
EG
NO
DI A
CC
ES
SO
ALL
A T
OR
RE
SC
EN
ICA
SE
ZIO
NE
AA
DAT
A :
SE
TTE
MB
RE
201
6
-1.80
-0.80TRAVE PRINCIPALE 12x28
TRAVETTI SECONDARI12x14 i=80 max.
PILASTRO12x24
PILASTRO12x24
TRAVETTO 12x14TRASVERSALE
TRAVE 12x28
PILASTRO PARAPETTO12x12
TRAVE SAGOMATA 12x28
PILASTRO12x24
TRAVE PRINCIPALE 12x28
1000
1750
600
-0.20
+1.552528
014
8528
012
80
SEZIONE B-BSCALA 1:25
SE20 - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICASEZIONE B-B
CARPLYsp.25 mm.
PART.1
PART.2
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
20 S
CA
LA :
1:2
5E
LAB
OR
ATO
GR
AFI
CO
: S
CA
LIN
ATA
IN L
EG
NO
DI A
CC
ES
SO
ALL
A T
OR
RE
SC
EN
ICA
SE
ZIO
NE
BB
DAT
A :
SE
TTE
MB
RE
201
6
SEZIONE C-CSCALA 1:25
SE21 - SCALINATA IN LEGNODI ACCESSO ALLA TORRE SCENICASEZIONE C-C
-1.80
-0.80TRAVE 12x28
PILASTRO12x24
600
-0.20
PART.2
CARPLYsp.40 mm.
TRAVE8x36 mm. TRAVE
12x36 mm.
TRAVE PRINCIPALE12x28 mm.
ELEMENTO IN LEGNODI FINITURA
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
21 S
CA
LA :
1:2
5E
LAB
OR
ATO
GR
AFI
CO
: S
CA
LIN
ATA
IN L
EG
NO
DI A
CC
ES
SO
ALL
A T
OR
RE
SC
EN
ICA
SE
ZIO
NE
CC
DAT
A :
SE
TTE
MB
RE
201
6
SE22 - STRUTTURA PORTANTEPARETE SCALA DI EMERGENZA
PROSPETTO ESTERNO PARETEScala 1:25
-1.80 q.p.f.-1.80 q.p.f.
-1.90-1.90
+3,30+3,301
+2.26+2.26
-1.80-1.80
-1.90-1.90
215(*)
(*) QUOTA DA VERIFICARECON PROGETTO
ARCHITETTONICO
STRUTTURA IN LEGNODI SOSTEGNO PANNELLI
DI TAMPONAMENTO
A
A
SEZIONE A-AScala 1:25
PART.1
215
PART. 1Scala 1:10
+3,30+3,30
IPE160
PIATTO sp.10 mm.SALDATO AL PROFILO IPE160E FISSATO ALLA STRUTTURA
IN LEGNO MEDIANTE OPPORTUNITASSELLI
STRUTTURA IN LEGNODI SOSTEGNO PANNELLI
DI TAMPONAMENTO
COLLEGAMENTOSUL MONTANTE
SALDATURAIN OFFICINA
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
VERIFICAREQUOTA ESIST.
PART.1
PR
OG
ET
TO E
SE
CU
TIV
O D
I LA
BO
RA
TOR
IO A
PE
RTO
NE
LL’E
X-TE
ATR
O V
ER
DI
Mo
Ve.r
di-
Rid
ing
, Dev
elo
pm
ent,
Insp
irat
ion
ELA
BO
RA
TO G
RA
FIC
O:
DA
TA:
TAV
OLA
:S
CA
LA:
+3
+2
+1
0-1-1
0+
1+
2+
3
TAVO
LA :
SE
22 S
CA
LA :
1:2
5 - 1
:10
ELA
BO
RAT
O G
RA
FIC
O :
STR
UTT
UR
A P
OR
TAN
TE P
AR
ETE
SC
ALA
DI E
ME
RG
EN
ZA
DAT
A :
SE
TTE
MB
RE
201
6