059.3/10 25/01/2010
C/ De la Fàbrica, 12 - 08711 Òdena (Barcelona) Tel. 93 331 28 05 Mòb. 606 79 40 31 [email protected] C/ Gaspar de Portolà, 4 Bxs. - 25280 Solsona (Lleida) Tel. 973 48 21 06
PROJECTE DE TELECOMUNICACIONS
- CABLEJAT ESTRUCTURAT, XARXA ETHERNET - WI-FI - INFRAESTRUCTURA RADIO/TELEVISIÓ
CENTRE CÍVIC CAN LLONG-CASTELLARNAU
SABADELL
059.3/10 25/01/2010
1
1.1.- Dades generals _____________________________________________ 1
2.- CABLEJAT ESTRUCTURAT _________________________________________________ 2
2.1.- Objecte de l’apartat de Cablejat Estructurat _______________________ 3
2.2.- Descripció de la solució proposada ______________________________ 3 2.2.A.- Descripció general ________________________________________________ 3 2.2.B.- Nivell de lloc de treball / punt d’accés sense fil _________________________ 4 2.2.C.- Nivell horitzontal _________________________________________________ 4 2.2.D.- Nivell vertical ___________________________________________________ 5 2.2.E.- Nivell d’administració _____________________________________________ 5 2.2.F.- Xarxa Sense fil ___________________________________________________ 6 2.2.G.- Telefonia _______________________________________________________ 7 2.2.H.- Etiquetatge i assignació de IPs ______________________________________ 8
2.2.H.a.- Plafó de connectors R0S1 ______________________________________________ 8 2.2.H.b.- Plafó de connectors R0S2 ______________________________________________ 9 2.2.H.c.- Plafó de connectors R0S3 _____________________________________________ 10
2.2.I.- Certificació _____________________________________________________ 11
3.- INFRAESTRUCTURA RADIO/TELEVISIÓ ________________________________ 12
3.1.- Dades generals ____________________________________________ 13 3.1.A.- Objecte de l’apartat d’Infraestructura de Radio/Televisió ________________ 13
3.2.- Elements que constitueixen la infraestructura de telecomunicacions ___ 13 3.2.A.- Captació i distribució de radiodifusió sonora i televisió terrenal ____________ 13
3.2.A.a.- Consideracions sobre el disseny ________________________________________ 13 3.2.A.b.- Senyals de radiodifusió sonora i televisió terrenals que es reben en l’emplaçament de l’antena ___________________________________________________________________ 13 3.2.A.c.- Selecció de l’emplaçament i paràmetres de les antenes receptores _____________ 17 3.2.A.d.- Càlcul dels suports per a la instal·lació de les antenes receptores ______________ 17 3.2.A.e.- Pla de freqüències ___________________________________________________ 18 3.2.A.f.- Amplificadors necessaris, número de derivadors/distribuïdors segons la seva posició en la xarxa i les seves característiques. ____________________________________________ 18 3.2.A.g.- Càlcul dels paràmetres bàsics de la instal·lació. ____________________________ 20
3.2.A.g.1 .- Nivell de senyal a la presa d’usuari en el millor i el pitjor cas ______________ 20
3.2.A.g.2 .- Resposta en Amplitud-Freqüència ___________________________________ 21
3.2.A.g.3 .- Càlcul de l’atenuació des dels amplificador de capçalera fins les preses d’usuari, a la banda de 15-862 MHz ____________________________________________________ 22
3.2.A.g.4 .- Relació senyal/soroll _____________________________________________ 22
3.2.A.g.5 .- Intermodulació _________________________________________________ 24
3.2.A.g.6 .- Nombre màxim de canals a incorporar a la instal·lació amb posterioritat _____ 26
3.2.B.- Distribució de radiodifusió sonora i televisió per satèl·lit _________________ 27
3.2.B.a.- Selecció de l’emplaçament i paràmetres de les antenes receptores del senyal de satèl·lit ___________________________________________________________________ 27 3.2.B.b.- Càlcul dels suports per la instal·lació de les antenes receptores del senyal de satèl·lit _________________________________________________________________________ 30 3.2.B.c.- Previsió per incorporar els senyals de satèl·lit ______________________________ 30 3.2.B.d.- Mescla dels senyals de radiodifusió sonora i televisió per satèl·lit amb els terrenals 31 3.2.B.e.- Amplificadors necessaris ______________________________________________ 31 3.2.B.f.- Càlcul dels paràmetres bàsics de la instal·lació _____________________________ 31
3.2.B.f.1 .- Nivell de senyal a la presa d’usuari en el millor i pitjor cas ________________ 31
3.2.B.f.2 .- Resposta Amplitud/Freqüència ______________________________________ 32
3.2.B.f.3 .- Càlcul de l’atenuació des dels amplificadors de capçalera fins les preses d’usuari, a la banda de 950 a 2150 MHz. ______________________________________________ 33
3.2.B.f.4 .- Relació portadora/soroll ___________________________________________ 33
3.2.B.f.5 .- Intermodulació __________________________________________________ 34
3.2.B.g.- Descripció dels elements components de la instal·lació ______________________ 36
3.2.B.g.1 .- Sistemes de captació _____________________________________________ 36
3.2.B.g.2 .- Amplificadors ___________________________________________________ 36
3.2.B.g.3 .- Materials complementaris _________________________________________ 36
3.2.C.- Accés i distribució del Servei de Telefonia _____________________________ 37 3.2.C.a.- Establiment de la Topologia i Infraestructura de la xarxa _____________________ 37 3.2.C.b.- Càlcul i dimensionament de la xarxa i tipus de cables. _______________________ 38
3.2.D.- Canalització i infraestructura de distribució ___________________________ 39 3.2.D.a.- Arqueta d’entrada i canalització externa __________________________________ 39 3.2.D.b.- Canalització d’enllaç superior i inferior ___________________________________ 40 3.2.D.c.- Registre de telecomunicacions de capçalera _______________________________ 40
3.2.D.c.1 .- Registre _______________________________________________________ 40
3.2.D.c.2 .- Equipament dels registre __________________________________________ 41
059.3/10 25/01/2010
2
3.2.D.d.- Registres de pas ____________________________________________________ 41
4.- PLÀNOLS __________________________________________________________________ 42
5.- PLEC DE CONDICIONS ___________________________________________________ 52
5.1.- CABLEJAT ESTRUCTURAT _____________________________________ 53 5.1.A.- Documentació prèvia a l'inici de les obres _____________________________ 53 5.1.B.- Condicions generals ______________________________________________ 54 5.1.C.- Prescripcions tècniques ___________________________________________ 55
5.1.C.a.- Armaris ___________________________________________________________ 55 5.1.C.b.- Cables ____________________________________________________________ 56 5.1.C.c.- Encaminador/Router _________________________________________________ 56 5.1.C.d.- Commutador/Switch _________________________________________________ 59 5.1.C.e.- Punts d’accés sense fil (APs) ___________________________________________ 62 5.1.C.f.- Controlador xarxa sense fil _____________________________________________ 65 5.1.C.g.- Canals plàstiques ____________________________________________________ 67 5.1.C.h.- Safates plàstiques ___________________________________________________ 67
5.1.D.- Condicions d’execució ____________________________________________ 68 5.1.D.a.- Sistemes de distribució de corrent elèctrica _______________________________ 68 5.1.D.b.- Cables ____________________________________________________________ 68 5.1.D.c.- Preses ____________________________________________________________ 68 5.1.D.d.- Armaris ___________________________________________________________ 69 5.1.D.e.- Canalitzacions ______________________________________________________ 69 5.1.D.f.- Canals plàstiques ____________________________________________________ 70 5.1.D.g.- Safates plàstiques ___________________________________________________ 70 5.1.D.h.- Equips electrònics per a la transmissió de dades ___________________________ 71 5.1.D.i.- Terra ______________________________________________________________ 72
5.1.E.- Instal·lació i certificació __________________________________________ 72
5.2.- INFRAESTRUCTURA RADIO / TELEVISIÓ _________________________ 74 5.2.A.- Radiodifusió sonora i televisió ______________________________________ 74
5.2.A.a.- Característiques dels sistemes de captació ________________________________ 74 5.2.A.b.- Característiques dels elements actius ____________________________________ 77 5.2.A.c.- Característiques del elements passius ____________________________________ 77
5.2.B.- Telefonia disponible al públic ______________________________________ 79 5.2.B.a.- Característiques dels cables: ___________________________________________ 79 5.2.B.b.- Característica de les regletes. __________________________________________ 80
5.2.C.- Infraestructura _________________________________________________ 80 5.2.C.a.- Característiques de les arquetes ________________________________________ 80 5.2.C.b.- Característiques de la canalització externa. _______________________________ 80 5.2.C.c.- Condicionants a tenir en compte en el registre de telecomunicacions. ___________ 81 5.2.C.d.- Característiques dels registres de planta i registres d’accés d’usuari. ____________ 81 5.2.C.e.- Característiques dels tubs. ____________________________________________ 82 5.2.C.f.- Requisits de seguretat entre instal·lacions. ________________________________ 82
5.2.D.- Quadre de mesures ______________________________________________ 82 5.2.D.a.- Radiodifusió sonora i televisió terrestres. _________________________________ 82
5.2.E.- Reglament de Prevenció de Riscs Laborals ____________________________ 83 5.2.F.- Normativa sobre protecció contra camps electromagnètics _______________ 84 5.2.G.- Altres. ________________________________________________________ 84
6.- ANNEX I: ATENUACIONS TOTALS EN PRESES D’USUARI ______________ 85
7.- ANNEX II: ESTUDI BÀSIC DE SEGURETAT I SALUT _____________________ 90
7.1.- MEMÒRIA DESCRIPTIVA _____________________________________ 91 7.1.A.- Objecte _______________________________________________________ 91 7.1.B.- Descripció dels treballs. Fases de l’obra ______________________________ 91
7.1.B.a.- Canalitzacions ______________________________________________________ 91 7.1.B.b.- Instal·lacions de RTV, TB+RDSI, TLCA i SAFI ______________________________ 91
7.1.C.- Treballs amb riscs especials _______________________________________ 91 7.1.D.- Riscs més freqüents. _____________________________________________ 92
7.1.D.a.- Riscs evitables ______________________________________________________ 92 7.1.D.b.- Riscs no evitables ___________________________________________________ 92
7.1.E.- Normes bàsiques de seguretat _____________________________________ 93 7.1.F.- Equips de protecció individual (E.P.I.). _______________________________ 93 7.1.G.- Proteccions col·lectives ___________________________________________ 94
7.1.G.a.- Senyalització _______________________________________________________ 94 7.1.G.b.- Instal·lació Elèctrica _________________________________________________ 95 7.1.G.c.- Mesures de seguretat en instal·lacions elèctriques. _________________________ 95 7.1.G.d.- Protecció contra incendis ______________________________________________ 96 7.1.G.e.- Mesures de seguretat contra el foc ______________________________________ 96 7.1.G.f.- Cables de subjecció de l’arnés de seguretat i els seus ancoratges ______________ 97
059.3/10 25/01/2010
3
7.1.G.g.- Escales de mà ______________________________________________________ 97
7.2.- Plànols ___________________________________________________ 97
7.3.- Plec de condicions particular __________________________________ 97
7.4.- Pressupost ________________________________________________ 99
8.- PRESSUPOST ____________________________________________________________ 100
059.3/10 25/01/2010
1
1.1.- Dades generals
L’edifici Centre Cívic Can Llong – Castellarnau objecte d’aquest projecte està situat a la
Avinguda d’Estrasburg de Sabadell. Aquest disposa de vàries estances les quals amb aquest
projecte es dotaran algunes d’elles dels serveis de Telecomunicacions aquí descrits en dos
apartats:
- CABLEJAT ESTRUCTURAT, XARXA ETHERNET - WIFI.
- INFRAESTRUCTURA DE RADIO/TELEVISIÓ TERRENAL I SATÈL·LIT
L’estructura i distribució de telecomunicacions detallada de l’edifici es troba representada a
l’apartat “PLÀNOLS” d’aquest projecte.
059.3/10 25/01/2010
2
2.- CABLEJAT ESTRUCTURAT XARXA ETHERNET - WI-FI
059.3/10 25/01/2010
3
2.1.- Objecte de l’apartat de Cablejat Estructurat L’objectiu d’aquest projecte és proporcionar la infraestructura de cablejat estructurat al
Centre Cívic Can Llong. El cablejat cobrirà les necessitats de veu (telefonia bàsica) i dades
(xarxa Ethernet). També es donarà cobertura de xarxa telemàtica inal·làmbrica (WIFI) a la
planta baixa i a la primera planta.
Hi haurà preses del cablejat estructurat a les següents estances:
Planta Baixa:
• recepció
• zona d’accés a internet
• sala polivalent
• oficina d’administració
• 2 espais tècnics
• sala de reunions
• gimnàs
• espai relacional
Primera Planta
• 3 aules tallers
• 1 aula taller amb cuina
S’ha planificat una configuració dels punts de xarxa en funció de les necessitats previstes. El
disseny permet canviar la configuració de qualsevol presa de l’edifici mitjançant el plafó de
connexions situat a l’armari de xarxa R0.
2.2.- Descripció de la solució proposada
2.2.A.- Descripció general
La solució adoptada empra únicament cable UTP de categoria 6. El cablejat va distribuït
mitjançant canalització amb safata de PVC, tubs de PVC i canaletes de PVC.
El cablejat estructurat serà certificat emprant la configuració estàndard T568B.
059.3/10 25/01/2010
4
El cablejat està organitzat amb una topologia en estrella. Hi ha un únic rack R0 situat a
l’armari d’instal·lacions. D’aquest armari en surten els cables UTP que van directament a
totes les preses de l’edifici.
S’han repartit 48 preses entre totes les sales de l’edifici que en requereixen. Entre aquestes
preses s’ha planificat la connexió de fins a 34 aparells IP i s’ha previst una línia de telèfon i
una de fax a la recepció. Finalment 12 preses s’han deixat lliures sense cap assignació.
Dins de l’armari de xarxa R0 hi ha un commutador (switch) de 48 boques i un router que
governa tota la xarxa.
Aquest disseny permet adaptar-se fàcilment a les futures necessitats de les instal·lacions.
Des de l’armari de xarxa R0 es poden redistribuir les connexions existents o assignar més
línies de telefonia o de xarxa telemàtica per a adaptar-se a futurs requeriments.
El Sistema de Distribució Integral es configura a partir dels nivells següents.
2.2.B.- Nivell de lloc de treball / punt d’accés sense fil
Aquest nivell enllaça el terminal d'usuari amb la resta del Sistema.
Els elements que integren aquest nivell són els adaptadors necessaris per a la integració dels
diferents terminals d'usuari i els seus servidors corresponents ( telèfons, terminals
informàtics, estacions de treball, AP, etc ) amb la resta del sistema.
Els aparells informàtics es connectaran a la xarxa mitjançant les preses situades als llocs de
treball amb fuetons (“latiguillos”) UTP de categoria 6 i 100 ohms. La seva longitud màxima
serà de 5m i els canals de transmissió constituïts hauran de complir les especificacions
recollides al plec de condicions.
Els aparells de telefonia bàsica es connectaran a les preses configurades per a aquesta funció
mitjançant l'adaptador corresponent. En cap cas es connectaran aparells de telefonia a les
preses de xarxa o viceversa.
2.2.C.- Nivell horitzontal
Aquest nivell inclou el conjunt d'elements necessaris per constituir l'enllaç entre nivell de lloc
de treball i nivell d'administració.
El cablejat del nivell horitzontal transcorre des dels plafons de connexions (patch panels) de
l’armari R0 fins als punts d’accés sense fil (Acces Points) i les preses de dades. Tot el cablejat
es realitza amb cables UTP de categoria 6.
059.3/10 25/01/2010
5
Els punts d’accés situats estratègicament donen cobertura de xarxa sense fil a tota la planta
baixa i primera planta. I amb les preses de dades arriba la xarxa telemàtica cablejada a totes
les estances que ho necessiten.
Al plànol de planta es pot observar la situació de les preses, dels punts d’accés i el recorregut
del cablejat proposat.
A la planta baixa el cablejat es distribueix a les diferents estances amb safates de PVC per
fals sostre i baixen a les preses amb tubs de PVC de 20mm de diàmetre. Per cada tub de
20mm circulen els dos cables UTP que donen servei a una àrea de treball. Per arribar a les
preses situades a les mampares que separen les diferents estances s’empraran canaletes de
PVC.
Al fals sostre de la planta baixa hi ha tres registres de 80x80 per accedir a la safata de
distribució, situats a l’entrada de l’oficina (zona 8), davant de recepció i a la sala polivalent.
A la planta primera arriben 16 cables UTP mitjançant dos tubs de PVC de 50mm de diàmetre.
El cablejat es distribueix fins a les preses amb safates, tubs i canaletes seguint els mateixos
criteris que a la planta baixa.
Els enllaços i canals constituïts amb aquests elements compliran les especificacions recollides
al Plec de Condicions.
2.2.D.- Nivell vertical
Compren el cablatge necessari per enllaçar el repartidor principal de veu i el de dades amb el
armari distribuïdor de planta.
Al tractar-se d’un edifici de dimensions reduïdes que necessita relativament poques preses a
la planta primera no serà necessari un nivell vertical.
La primera planta serà servida directament des de l’armari de xarxa R0 situat a la planta
baixa.
2.2.E.- Nivell d’administració
Integren aquest nivell els elements que proporcionen la terminació dels cables que formen els
nivells vertical i horitzontal, així com les interfícies necessàries per a la reassignació.
Aquest nivell permetrà suportar la totalitat de punts a instal·lar.
Hi ha un sol armari de xarxa R0 a la planta baixa que serveix a tot l’edifici. És una caixa
mural Rittal QuickBox de 21 UA (1028mm) situada dins l’armari d’instal·lacions a la planta
059.3/10 25/01/2010
6
baixa entre la recepció i la sala de la caldera. Les seves dimensions són 600mm de
profunditat i 600mm d’amplada.
Aquesta caixa conté el següent:
- bastidors de 19¨ de 21 UA
- 1 regleta d’endolls Rittal de 7 bases
- 3 plafons de 24 connexions tipus RJ49 de categoria 6
- 1 commutador gigabit ethernet Cisco WS-C2960G-48TC-L (48 x 10/100/1000Base-T
LAN)
- 1 encaminador (router) Cisco1941/K9
- 1 controlador de xarxa sense fil Cisco 2100
Els plafons es connectaran al commutador mitjançant fuetons (“latiguillos”) seguint les taules
de l’apartat següent.
El commutador es configurarà per tal d’assignar IPs mitjançant DHCP a cada un dels seus
ports segons les taules de l’apartat següent.
El port 1 del commutador està reservat per a la connexió de l’encaminador. Es contempla la
possibilitat que la companyia proveïdora d’accés a Internet proporcioni l’encaminador de
prestacions comparables al recomanat.
2.2.F.- Xarxa Sense fil
La xarxa sense fil estarà constituïda per un controlador WLAN Cisco 2100 i 6 punts d’accés
Cisco Aironet 1140.
Es disposa d’un punt d’accés a la xarxa sense fil (AP) a la primera planta i de 5 punts d’accés
a la planta baixa per a donar cobertura a tot l’interior de l’edifici i al pati. Aquests punts
d’accés s’instal·len al punt més alt de la paret i es comuniquen amb el switch de l’armari R0
mitjançant cable UTP de categoria 6.
La sala polivalent està servida per una AP situada dins la sala ja que s’hi preveu una gran
demanda i a més té un aïllament considerable. A l’espai relacional hi ha un punt d’accés que
també donarà cobertura al pati. Al passadís de l’àrea d’administració hi ha un punt d’accés
que dóna cobertura a tota l’àrea inclosos els despatxos, l’oficina i la sala de reunions. A la
059.3/10 25/01/2010
7
recepció hi ha un punt d’accés que també donarà servei a l’àrea d’Internet i finalment el
gimnàs té el seu propi punt d’accés.
La situació prevista dels punts d’accés es pot observar al plànol de planta.
Els punts d’accés es configuraran amb dues SSID per a conformar dues xarxes sense fil
independents. Una xarxa privada permetrà als usuaris autoritzats a accedir a la xarxa
telemàtica privada del centre (intranet). Una segona SSID configurarà una xarxa pública que
permetrà als visitants connectar-se a Internet sense necessitat d’autorització però no els
permetrà accedir a la intranet.
S’ha previst la disponibilitat d’una presa d’alimentació elèctrica al costat de cada punt d’accés
a la xarxa sense fil. Aquest projecte no contempla la possibilitat d’alimentar els AP amb el
mateix cablejat estructurat mitjançant Power over Ethernet (PoE). Si es volgués emprar PoE
s’haurien de considerar les implicacions en termes de necessitat de ventilació de l’equipament
de xarxa o l’injector de potència emprat i reflectir-les en un annex a aquest projecte.
2.2.G.- Telefonia
S’ha previst l’entrada de fins a 5 línies de telefonia bàsica a l’edifici que arribaran en una
regleta situada al mateix armari d’instal·lacions que allotja la caixa mural de xarxa.
S’han assignat dues línies a la zona d’administració: una per al telèfon i l’altra per al fax. En
cas de disposar de més línies es poden assignar a les preses de telefonia repartides entre les
estances de l’edifici.
La distribució del subsistema de veu serà de tipus transparent, des del quadre principal fins a
cada una de les connexions terminals de veu. Les línies de telefonia es cablejaran als panells
de la caixa R0 d’acord amb les taules de l’apartat següent i mitjançant els adaptadors
corresponents.
Aquest projecte no contempla la instal·lació d’una centraleta telefònica però proporciona la
infraestructura per a possibilitar-ne una instal·lació posterior. Tant sols caldrà assignar les
línies de telèfon a la centraleta i cablejar la sortida de la centraleta al plafó de connexions.
En cas d’una futura instal·lació d’una centraleta IP es podrà prescindir dels adaptadors de la
xarxa de telefonia. En cas de voler alimentar els telèfons des del mateix cablejat estructurat,
amb PoE (Power over Ethernet) caldrà considerar les necessitats de ventilació i refrigeració
dels equips necessaris.
059.3/10 25/01/2010
8
2.2.H.- Etiquetatge i assignació de IPs
Les 6 preses corresponents als punts d’accés sense fil van connectades als ports
corresponents del controlador de la xarxa sense fil (WLAN a la taula). La resta de preses van
connectades al commutador (switch).
Els plafons, els cables i les preses s’etiquetaran amb el nom de la presa segons les taules
següents.
2.2.H.a.-Plafó de connectors R0S1 Connector Presa Commutador IP
1 P0301A 2 192.168.1.2
2 P0301B TELEFON
3 P0302A 3 192.168.1.3
4 P0302B FAX
5 P0303A WLAN 1 192.168.1.51
6 P0401A WLAN 2 192.168.1.52
7 P0501A 4 192.168.1.4
8 P0502A 5 192.168.1.5
95 P0503A 6 192.168.1.6
10 P0504A 7 192.168.1.7
11 P0505A 8 192.168.1.8
12 P0601A 9 192.168.1.9
13 P0601B 10 192.168.1.10
14 P0602A WLAN 3 192.168.1.53
15 P0603A LLIURE
16 P0604A 11 192.168.1.11
17 P0701A WLAN 4 192.168.1.54
18 P0702A 12 192.168.1.12
19 P0702B LLIURE
20 P0901A WLAN 5 192.168.1.55
21
22
23
24
059.3/10 25/01/2010
9
2.2.H.b.-Plafó de connectors R0S2 Connector Presa Switch IP
1 P1001A 13 192.168.1.13
2 P1001B LLIURE
3 P1002A 14 192.168.1.14
4 P1002B LLIURE
5 P1003A 15 192.168.1.15
6 P1003B LLIURE
7 P1004A 16 192.168.1.16
8 P1004B LLIURE
9 P1101A 17 192.168.1.17
10 P1101B 18 192.168.1.18
11 P1101C LLIURE
12 P1201A 19 192.168.1.19
13 P1202A 20 192.168.1.20
14 P1202B 21 192.168.1.21
15 P1301A 22 192.168.1.22
16 P1301B LLIURE
17 P1302A 23 192.168.1.23
18
19
20
21
22
23
24
059.3/10 25/01/2010
10
2.2.H.c.-Plafó de connectors R0S3 Connector Presa Switch IP
1 P2501A WLAN 6 192.168.1.56
2 P2601A 24 192.168.1.24
3 P2601B LLIURE
4 P2701A 25 192.168.1.25
5 P2701B 26 192.168.1.26
6 P2702A 27 192.168.1.27
7 P2702B LLIURE
8 P2703A 28 192.168.1.28
9 P2703B 29 192.168.1.29
10 P2704A 30 192.168.1.30
11 P2704B LLIURE
12 P2801A 31 192.168.1.31
13 P2801B 32 192.168.1.32
14 P2802A 33 192.168.1.33
15 P2802B LLIURE
16 P2901A 34 192.168.1.34
17
18
19
20 RESERVAT TB
21 RESERVAT TB
22 RESERVAT TB
23 TB L2 FAX
24 TB L1 TELEFON
059.3/10 25/01/2010
11
2.2.I.- Certificació El cablejat estructurat serà certificat emprant la configuració T568B. La memòria de les proves de certificació inclourà l’informe de l’arxiu font de la màquina certificadora. La certificació aportarà informació sobre els resultats de les proves realitzades a les diferents dependències de l’edifici amb l’objectiu del compliment de les normes de certificació del cablatge. 1. Mapa de cablatge 2. Temps de propagació i diferència de retard 3. Distància 4. Atenuació (Pèrdues d’inserció) 5. NEXT (Near End Crosstalk o Diafonia) 6. ELFEXT 7. ACR 8. Resistència 9. Power Sum (PSNEXT, PSACR, PSELFEXT) 10. Pèrdues de retorn
Òdena, 25 de Gener de 2010
Francesc Romà Frigolé
Enginyer de Telecomunicació Col·legiat Num. 12.461
059.3/10 25/01/2010
12
3.- INFRAESTRUCTURA RADIO/TELEVISIÓ
059.3/10 25/01/2010
13
3.1.- Dades generals
3.1.A.- Objecte de l’apartat d’Infraestructura de Radio/Televisió Aquest apartat dissenya la Infraestructura de Telecomunicacions de la que es dotarà l’edifici
de referència.
L’objectiu d’aquest apartat és complir mitjançant l’adequada distribució dels senyals de
televisió terrenal i de telefonia, així com la previsió per incorporar la televisió per satèl·lit i els
serveis de telecomunicacions de banda ampla adequant-se a les característiques particulars
de l’edifici.
Així doncs, en aquest projecte, es justifica tècnicament, mitjançant els corresponents càlculs,
detalls i especificacions, tots i cada un dels elements components de la Infraestructura de
Telecomunicacions, amb els que haurà de ser dotat l’edifici descrit en l’apartat anterior, així
com el conjunt de la mateixa i la seva instal·lació.
3.2.- Elements que constitueixen la infraestructura de telecomunicacions
3.2.A.- Captació i distribució de radiodifusió sonora i televisió terrenal
3.2.A.a.-Consideracions sobre el disseny
La xarxa de distribució estarà preparada per permetre la distribució del senyal, de manera
transparent, entre la capçalera i les preses d’ús a la banda de freqüències compresa entre 47
i 2150 MHz.
En el cablejat que composa la xarxa de distribució s’hi situaran els senyals procedents del
conjunt d’elements captadors d’emissions terrestres, quedant la resta de l’ample de banda
del cable disponible per situar-hi, de manera alternativa, els senyals procedents del possible
conjunts addicional de l’element de captació d’emissions de radiodifusió sonora i televisió per
satèl·lit.
3.2.A.b.-Senyals de radiodifusió sonora i televisió terrenals que es reben en l’emplaçament de l’antena
Es considera que a la ubicació de les antenes es disposa d’un nivell de senyal per cada canal
superior al mínim que marca la norma tècnica.
059.3/10 25/01/2010
14
Aquesta normativa tècnica determina les condicions mínimes que ha de complir un senyal per
ser distribuït en funció del valor del camp elèctric d’aquest senyal en el punt de recepció.
• CÀLCUL TEÒRIC DEL NIVELL DE SENYAL
Per relacionar la tensió (que és la magnitud observable amb el mesurador de camp)
amb el valor del camp elèctric corresponent, començarem per trobar l’expressió que relaciona
aquest camp amb la tensió generada per un dipol de λ/2.
El circuit equivalent d’un dipol de λ/2 és el següent:
L’expressió que relaciona el camp elèctric rebut E amb el potencial generat per aquest circuit
és la següent:
dxdVdE −=
on el signe negatiu simplement indica que el camp va en el sentit dels potencial negatius.
Aquesta expressió seria definitiva si no fos perquè la distribució de corrent en un dipol no és
constant i, per tant, cal trobar l’expressió de l’alçada efectiva d’aquest dipol:
πλ
=eh
L’expressió del potencial donat per un dipol de λ/2 en funció del camp que rep serà, per tant:
EV ·'πλ
=
Aquesta equació, però, no té en compte que per realitzar les nostres mesures de tensió amb
el mesurador de camp, estem utilitzant una antena de guany G que cal considerar a l’hora de
plantejar aquestes equacions:
GEV ··'πλ
=
059.3/10 25/01/2010
15
Aquesta expressió ja reflexa els efectes de la distribució de camp en un dipol i el guany de
l’antena. Ara bé, el mesurador de camp que posem a la sortida de l’antena té una impedància
d’entrada igual a la impedància de l’antena (en aquest cas 75Ω). Si considerem aquesta
impedància, el circuit equivalent i les equacions que se’n deriven són les següents:
GEV ··2
'πλ
= ,on ff
c 810·3==λ
En dB:
)()(2
log20)( dBGm
VdBEVdBV ++⎟⎠⎞
⎜⎝⎛=
μπλμ
• NIVELLS MÍNIMS DELS SENYALS A DISTRIBUIR Així doncs, considerant que es realitzen les mesures amb una antena Yagi de 16 dBi (que
corresponen a 14 dB respecte el dipol de mitja ona), tindrem que els nivells mínims que cal
rebre per cada canal perquè sigui obligatòria la seva distribució seran els que marca la taula
següent, on hi figuren les següents magnituds: la primera columna correspon al nom de
l’emissora, la segona és el canal a través del qual es distribueix en el punt d’emplaçament de
les antenes, la tercera és la longitud d’ona corresponent a aquest canal, la quarta és el nivell
de camp mínim que marca la obligatorietat de distribuir el canal, i l’última columna és el
nivell mínim de tensió que ens ha de donar el mesurador de camp per tal que la distribució
d’aquest canal sigui obligatòria (mesurat amb una antena de 16dBi).
A diferència dels canals analògics, en el cas dels canals digitals cal realitzar un simple càlcul
per saber la intensitat mínima de camp exigible al senyal:
⎥⎦⎤
⎢⎣⎡⋅+=
mVdBMHzfE μ)(log2011min
059.3/10 25/01/2010
16
Programa Canal λ (m) Camp Mínim Teòric
Tensión mínima Freqüencia
(dBμV/m) (dBμV) Port.Video
CANALS DIGITALS
EDC 33 0,528867342 58,07549 42,5788 567,25LOCAL PRIVAT TL07B 39 0,487606664 58,78103 42,5788 615,25TVC 43 0,463499421 59,22144 42,5788 647,25LOCAL TL12B 45 0,452318130 59,43355 42,5788 663,25CCRTV 61 0,379146919 60,96627 42,5788 791,25RTVE 64 0,367985281 61,22582 42,5788 815,25Veo Veo2 NetTV 66 0,360902256 61,39463 42,5788 831,25Teledeporte Cuatro La sexta 67 0,35746202 61,47783 42,5788 839,2540 Latino TV Tele 5 Flymusic 68 0,354086751 61,56023 42,5788 847,25Antena 3 La sexta 2 69 0,350774627 61,64186 42,5788 855,25
•RELACIÓ PORTADORA/SOROLL
Els paràmetres de qualitat S/N i C/N (relació senyal/soroll i portadora/soroll respectivament),
són sensiblement iguals per senyals de televisió terrestre analògica amb el vídeo modulat en
amplitud.
El càlcul de la relació S/N s’acostuma a realitzar en dB, ja que d’aquesta manera es redueix a
una simple resta: cal restar el nivell de senyal rebut menys el nivell de soroll que porta
aquest senyal.
1. El nivell de senyal rebut és el que ens dóna el mesurador de camp en el punt
d’ubicació de les antenes.
2. El nivell de soroll que porta aquests senyal el calcularem com la tensió produïda per la
potència de soroll tèrmic sobre una impedància de 75Ω, que és la que apareix en el
circuit equivalent d’un dipol de mitja ona:
BTKPr ⋅⋅=
K és la constant de Boltzman: K= 1.38·10-23 J/ºK
T és la temperatura absoluta: prendrem T= 293 ºK
B és l’ample de banda del senyal: B= 5 MHz
Segons aquests valors, la potència de soroll tèrmic és:
059.3/10 25/01/2010
17
14623 10·0217.21052931038.1 −=⋅⋅⋅⋅=rP
Igual que en qualsevol circuit elèctric, la potència dissipada per una resistència és la
relació entre el quadrat de la tensió que hi cau i el valor de la resistència:
VPV rr μ23137.175 =Ω⋅= que, expressats en dB són: 20·log( Vr)=1.8 dBμV
Normalment es pren un valor de 2 dBμV i, per tant, per obtenir la relació portadora/soroll
del senyal rebut, n’hi ha prou restant-li aquests 2 dB de soroll (pel cas del dipol de mitja
ona, que representa una impedància de 75Ω).
3.2.A.c.-Selecció de l’emplaçament i paràmetres de les antenes receptores
L’emplaçament definitiu dels suports de les antenes per als serveis de radiodifusió sonora i
TV terrenals, per a cadascuna de les instal·lacions, se situen a la planta coberta.
- Veure plànols d’instal·lacions i plec de condicions (apartat 5.2.A.a), on s’indiquen
la situació i les característiques de l’asta i antenes.
3.2.A.d.-Càlcul dels suports per a la instal·lació de les antenes receptores
El conjunt dels elements de captació de la radiodifusió sonora i televisió, haurà de suportar
velocitats del vent de fins a 150 Km/h, així com cada un d’aquests elements independents.
En el tipus d’instal·lació que estem tractant, l’element més crític de la mateixa pel que als
esforços es refereix, és l’asta suportant de les antenes. Es realitzaran els càlculs considerant
el pitjor cas (instal·lació de l’antena de TV i d’FM en el punt més alt de l’asta).
El catàleg del fabricant ens indica la pressió de vent en N/m2 per una càrrega de vent de 800
N/m2.
Com que l’asta que s’instal·la està formada d’un únic tub, el moment flector d’aquest (indicat
pel fabricant), inclou el de la pròpia asta, amb la qual cosa només cal comprovar que el
moment flector degut a les antenes és inferior al de l’asta, indicat en el catàleg.
S’utilitzarà una asta capaç d’aguantar un moment flector superior a 172.5 Nm.
L’asta escollida tindrà 35 mm de diàmetre, 1,5 mm de gruix i un moment flector de 299.7
Nm.
059.3/10 25/01/2010
18
3.2.A.e.-Pla de freqüències
A continuació es detalla a la taula següent el pla de freqüències a seguir en la ICT, d’acord
amb els canals rebuts en l’emplaçament.
Banda Canals
utilitzats Canals
interferents Servei
recomanat
BI No utilitzada BII FM-ràdio
BS(alta i baixa) TV CABLE
BIII TVSAT A/D
Radio D Terrestre
Hiperbanda Cap TV CABLE
BIV 23,27,31,34,39
TV A/D Terrestre
BV 41,44,45,47,49,65,63,50,61,
64,66,67,68,69 TV A/D Terrestre
950-1446 MHz TVSAT A/D (FI)
1452-1492 MHz Radio D SAT
1494-2150 MHz TVSAT A/D (FI)
Si en el moment de la instal·lació de les antenes s’observa que en aquell punt la recepció
d’alguns dels canals és millor a través d’algun altre repetidor, es pot instal·lar una segona
antena.
La banda utilitzada per la distribució d’aquests senyals serà de 950 a 2150 MHz, evitant així
que la distribució dels senyals de TV satèl·lit interfereixin amb els de TV terrestre.
3.2.A.f.-Amplificadors necessaris, número de derivadors/distribuïdors segons la seva posició en la xarxa i les seves característiques.
Per tal de decidir el tipus i quantitat d’amplificadors que són necessaris a la capçalera de la
instal·lació, cal conèixer l’atenuació que introdueix la xarxa de distribució a cada presa
d’usuari o, com a mínim, cal saber els nivells màxim i mínim d’atenuació. El càlcul de
l’atenuació que introdueix la xarxa de distribució, segons l’esquema de la infraestructura
descrit en el plànol nº T-08, dóna el següent resultat:
059.3/10 25/01/2010
19
Atenuació dB Espai
Màxima 39.43 Sala Pol.
Mínima 19.86 Gimnàs
Amb les dades de l’atenuació anteriors (màxima i mínima) que introdueix la xarxa i els
nivells de senyal desitjats a la presa d’usuari, podem calcular l’amplificació necessària.
Els nivells desitjats a la presa d’usuari, són els següents:
- Entre 45 i 70dBμV per COFDM-TV (TDT).
Aplicant un marge d’error per assegurar un nivell òptim de senyal a totes les preses d’usuari,
el sistema d’amplificació proposat pels senyals de TV terrestre serà el següent:
Tipus Central d’amplificació programable amb filtres
selectius a l’entrada per tractament de canals
adjacents.
Guany UHF Automàtic en funció del nivell de sortida
programat
Figura màxima de soroll 10 dB
Si un cop realitzada la instal·lació, per culpa de l’arrissat en la resposta dels elements de la
xarxa, resultés un nivell inferior en algun dels programes distribuïts, es variarà la sortida dels
amplificadors corresponents (augmentant el seu guany) fins a obtenir el nivell desitjat.
Esquema de la infraestructura: veure plànol nº T-08.
Característiques dels amplificadors: veure plec de condicions.
La xarxa de distribució es realitzarà mitjançant derivadors i distribuïdors o repartidor a cada
planta.
El nombre de sortides de cada repartidor i la seva distribució es pot observar als plànols i al
esquema de la infraestructura de la instal·lació de radiodifusió i televisió (plànol T-08).
A continuació es detallen les característiques més importants d’aquests elements:
059.3/10 25/01/2010
20
Derivadors de 2 sortides Atenuació per derivació Atenuació de pas (dB) UHF FI UHF FI
15 15 1,2 2
Distribuidors - Repartidors Nº sortides Atenuació UHF (dB) Atenuació FI (dB)
2 4,5 5,5 3 7 9
3.2.A.g.-Càlcul dels paràmetres bàsics de la instal·lació. A continuació es detallen els càlculs dels paràmetres bàsics de la xarxa en la captació,
adaptació i distribució de senyals de radiodifusió sonora i televisió terrenal, procedent
d’emissions terrenals.
3.2.A.g.1 .- Nivell de senyal a la presa d’usuari en el millor i el pitjor cas
El següent quadre mostra el càlcul de l’atenuació a diferents freqüències a la millor i pitjor
presa:
PLANTA PB ESPAI GIMNÂS PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor X Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 0,0 15,0 0,0 0,0 26,0 1,04 16,04200 2,08 17,08600 3,69 18,69800 4,00 19,00
PLANTA PB
ESPAI SALA POLIVALENT
PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 2 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 1,2 15,00 0,00 4,50 59,0 2,36 23,06200 4,72 25,42600 8,38 29,08800 9,09 29,79
059.3/10 25/01/2010
21
Per tal de calcular el nivell de sortida de la central amplificadora de capçalera que volem
aconseguir, a partir de l’atenuació (màxima i mínima) i aplicant un marge d’error suficient
per assegurar un nivell òptim de senyal a totes les preses d’usuari, cal ajustar el nivell de
senyal a la sortida de la capçalera els següents valors:
Sortida capçalera AM-TV 80 dBμV
Amb aquests nivells de sortida de capçalera i els nivells d’atenuació a la millor i pitjor presa
seran els següents:
PLANTA Baixa PLANTA Baixa ESPAI Gimnàs ESPAI Sala Pol. PRESA Única PRESA Cuina FREQ. (MHz) Nivell (dB) FREQ. (MHz) Nivell (dB)
50 63,96 50 56,94
200 62,92 200 54,58
600 61,31 600 50,92
800 61,00 800 50,21
Es pot comprovar que totes les preses estan dins dels marges requerits per la normativa.
3.2.A.g.2 .- Resposta en Amplitud-Freqüència
L’atenuació que introdueixen els elements de la xarxa depèn de la freqüència, i el que es
pretén mesurar amb aquest paràmetre és precisament la desviació de l’amplitud respecte
d’una resposta plana ideal amb la freqüència.
Es distingeixen dues mesures diferents per aquesta magnitud:
- Resposta amplitud/freqüència en canal: aquesta és una mesura que cal realitzar un
cop acabada la instal·lació.
En el servei de radiodifusió terrestre, es tracta de mesurar la diferència de nivell entre la
portadora de vídeo i la portadora d’àudio a la sortida de la capçalera i anotar-ne el valor.
Desprès cal repetir la mateixa mesura a totes les preses d’usuari. La diferència entre el
valor mesurat a la capçalera i qualsevol dels altres valors ha de ser més petita de 3 dB.
Les raons per les quals pot no complir-se aquest requisit són sempre degudes a defectes de
la instal·lació, com per exemple elements passius defectuosos, males connexions, brides
que aixafen el coaxial a l’entrada o sortida d’elements passius, cables escanyats,
desadaptacions d’impedàncies, etc. En aquest cas, caldrà realitzar la mesura a la sortida de
tots els elements passius afectats, fins a trobar on es produeix la desadaptació.
059.3/10 25/01/2010
22
- Resposta amplitud/freqüència en banda de la xarxa: és la diferència entre les
atenuacions, a les freqüències més alta i més baixa, de la millor i la pitjor presa, per la
banda de 15 a 862 MHz. Aquest paràmetre caracteritza la quantitat dels elements que
constitueixen la xarxa (cables, derivadors, preses, etc.) pel que fa a toleràncies i
compliment respecte la freqüència.
Es pot realitzar una estimació teòrica d’aquesta magnitud utilitzant les dades que faciliten
els fabricants sobre les característiques dels cables, però per conèixer exactament la
resposta amplitud/freqüència de la xarxa, caldrà mesurar-la un cop acabada la instal·lació,
ja que no es disposa de les toleràncies de tots els elements passius (derivadors, PAU, etc.)
que s’utilitzen.
Els nivells d’atenuació a diferents freqüències per la millor i la pitjor presa ja han estat
calculades al començament d’aquest apartat. A partir d’aquells valors, la resposta
amplitud/freqüència és la següent:
AMPLITUD/FREQÜÈNCIA A LA MILLOR PRESA 2,96 (dB) AMPLITUD/FREQÜÈNCIA A LA PITJOR PRESA 6,73 (dB)
3.2.A.g.3 .- Càlcul de l’atenuació des dels amplificador de capçalera fins les preses d’usuari, a la banda de 15-862 MHz
Tenint en compte la fórmula per a calcular l’atenuació total des de la capçalera fins a
cada presa d’usuari, les atenuacions dels dispositius que composen la xarxa i les
atenuacions del cablejat coaxial, així com la seva distribució i els metres de cablejat fins
a cada presa, indicat a l’esquema de la infraestructura, s’indiquen en l’Annex I del
present projecte les atenuacions totals en totes les preses de cada estança.
3.2.A.g.4 .- Relació senyal/soroll La relació portadora/soroll (C/N) a la presa defineix la qualitat del senyal rebut i el soroll
present a través de tot el sistema de recepció (elements captadors, capçalera i xarxa).
Es pot considerar que la relació C/N del senyal a la presa d’usuari per canals de 8MHz
d’amplada modulats en amplitud és sensiblement igual a la relació S/N del mateix senyal.
Segons els càlculs desenvolupats a l’apartat 1.2.A.b, sabem que per obtenir la relació
portadora/soroll del senyal a la sortida de l’antena, n’hi ha prou restant-li 2 dB de soroll (pel
cas del dipol de mitja ona, que presenta una impedància de 75Ω).
059.3/10 25/01/2010
23
Per calcular la relació C/N del senyal a la pitjor presa, utilitzarem la fórmula de Friis, definida
per una cadena de quadripols en cascada:
gnggfn
ggf
gfff
⋅⋅⋅−
++⋅−
+−
+=...1...
11
1111
3
1
21
On f1, f2,..., fn són els factors de soroll de cada quadripol.
g1, g2,..., gn són els guanys de cada quadripol.
Per saber si la relació C/N que rebrem a la presa d’usuari compleix la norma tècnica
corresponent cal tenir en compte l’atenuació que introdueixen els elements passius (tant el
cable fins a l’entrada del primer amplificador, com els elements de la xarxa de distribució) i la
figura de soroll que presenten els amplificadors de la instal·lació.
Una instal·lació de la xarxa correspon al següent esquema:
ANTENA
CABLE DE BAIXADA
XARXA DE L'EDIFICI
a1
a3 PRESA D'USUARIf2, g2
CAPÇALERA
El factor de soroll que introdueixen tant el cable antena-capçalera, com la xarxa de l’edifici,
són iguals a la seva atenuació (en el cas de la xarxa prendrem l’atenuació calculada
anteriorment a la pitjor presa).
Respecte l’amplificador, el factor de soroll es relaciona amb la figura de soroll (que és la
magnitud que ens proporciona el fabricant) mitjançant la següent equació:
)·log(10 fF =
Amb totes aquestes dades podem calcular la relació C/N a la pitjor presa de la instal·lació:
059.3/10 25/01/2010
24
13
3121 ·
1)·1( a
ga
afaf−
+−+=
On a1 es l’atenuació del cable antena-capçalera.
f2 és el factor de soroll de l’amplificador de capçalera .
g2 és el guany d’aquest amplificador.
a3 és l’atenuació que introdueix la xarxa per la pitjor presa d’usuari.
A partir d’aquí, el càlcul de la relació C/N a la pitjor presa es redueix a una simple resta:
)()(V)()(/ dBNdBFdBCdBNC −−= μ
on N és la potència de soroll tèrmic del senyal a la sortida de l’antena calculada
anteriorment, i que es pren sempre de 2 dB.
La norma tècnica aplicable ens indica que la relació C/N per canals de TV modulats en AM ha
de ser més gran o igual a 43 dB. Substituint aquest valor a l’equació anterior trobarem el
nivell mínim de senyal que necessitem.
A continuació es detallen els valors de la instal·lació:
RELACIÓ C/N CABLE Atenuació (dB) 1,08CAPÇALERA Figura de soroll (dB) 9 Guany (dB) 80XARXA Atenuació (dB) 29,79 FRIIS f= 10,080C/N mínima (dB) RD 401/2003 43C(dBμV) 55,08
En el cas que el nivell de senyal rebut per algun canal fos inferior a aquesta magnitud
(C(dBμV)) i es volgués distribuir igualment, seria necessària la introducció d’un amplificador
previ (amb F molt petita i guany elevat), amb la qual cosa la figura de soroll introduïda pel
sistema es reduiria considerablement i, per tant, les restriccions de la normativa tècnica es
complirien amb menys nivell de senyal a l’entrada.
3.2.A.g.5 .- Intermodulació • INTERMODULACIÓ SIMPLE
059.3/10 25/01/2010
25
La intermodulació simple s’interpreta com els productes provocats per les 3 portadores
presents en un canal de TV (portadores d’àudio, vídeo i color). La generació d’aquesta
intermodulació simple s’utilitza per tipificar la tensió màxima de sortida d’amplificadors
monocanal.
El seu càlcul es pot establir com una intermodulació de triple batec:
)·(2 _ MAXoutoutref
VVCTB
CCTB
C−−⎟
⎠⎞
⎜⎝⎛=
On: refCTB
C⎟⎠⎞
⎜⎝⎛
= 54 dB per la majoria d’amplificadors.
Vout_MAX: característica de l’amplificador.
Vout: nivell real de sortida de l’amplificador.
D’aquesta fórmula es pot deduir fàcilment que un amplificador monocanal que està treballant
per sota de la seva tensió màxima de sortida mantindrà sempre la intermodulació per sobre
de 54 dB, que és el límit que marca la norma tècnica.
• INTERMODULACIÓ MÚLTIPLA
Definim la intermodulació múltipla com els productes de tercer ordre provocats pel batec dels
diversos canals presents a la banda de transmissió. És a dir, el senyal de cada canal apareix
distorsionat per un senyal de banda lateral generat pels altres canals amplificats.
Aquest tipus d’intermodulació es detecta a simple vista a qualsevol monitor de televisió, ja
que apareix una banda imprecisa que es desplaça per la pantalla.
La generació de la intermodulació múltipla s’utilitza per tipificar la tensió màxima de sortida
en amplificadors de banda ampla, i el seu càlcul es realitza segons la següent expressió:
[ ])1·log(5,7·2 −−−+⎟⎠⎞
⎜⎝⎛=⎟
⎠⎞
⎜⎝⎛ nSS
XMC
XMC
MAXrealrefs
on: refXM
C⎟⎠⎞
⎜⎝⎛
=60 dB per TV-AM a la majoria d’amplificadors.
Sreal: nivell de sortida de l’amplificador.
059.3/10 25/01/2010
26
SMAX: nivell màxim de sortida de l’amplificador quan només amplifica dos canals (el
proporciona el fabricant).
n: nombre de canals que ha d’amplificar la central.
Segons la norma tècnica corresponent, el nivell màxim que pot presentar aquesta
intermodulació és de 54 dB. Per assegurar aquest nivell, realitzarem els càlculs considerant
que volem aconseguir una intermodulació múltipla de 60 dB, és a dir, igual al nivell de
referència. L’equació a resoldre és per tant, la següent:
[ ])1·log(5,7·26060 −−−+= nSS MAXreal
A partir d’aquí arribem a l’expressió que ens permetrà calcular el nivell màxim de sortida que
podem exigir a una central de banda ampla:
)1·log(5,7 −−= nSS MAXreal
on Sreal: nivell màxim de sortida que podem exigir a la central.
SMAX: nivell màxim de sortida quan la central amplifica només 2 canals.
N: nombre de canals que volem amplificar.
En el cas de la instal·lació dissenyada el càlcul d’aquesta magnitud és el següent:
6,108)114·log(5,7117 =−−=realS
3.2.A.g.6 .- Nombre màxim de canals a incorporar a la instal·lació amb posterioritat
Degut a què la instal·lació contempla la utilització d’una central amplificadora programable, i
amb la finalitat de facilitar al titular de la propietat la informació necessària respecte a
possibles ampliacions de la infraestructura, a continuació s’inclouen detalls relatius al
número de canals de televisió no considerats en aquest projecte original. En un futur se’n
podrien incorporar més a la instal·lació, i per tal de poder mantenir aquesta amb les mateixes
característiques que aquest document contempla. Aquests valors estaran dins dels límits
establerts en l’annex I del Reglament, aprovat pel el Real Decret 401/2003, de 4 de abril.
Tenim :
)1·log(15)(2 −−−+= nSsSmXMnXmC
On:
059.3/10 25/01/2010
27
XMn= Valor de la relació Portadora/Intermodulació múltiple a la sortida de
l’amplificador per a dos canals amb nivell màxim de sortida (Característica de l’amplificador).
Sm= Nivell màxim de sortida de l’amplificador (Característica de l’amplificador).
Ss=Nivell d’ajust a la sortida de l’amplificador.
N= número de canals que s’ amplifiquen.
Aïllant n, obtenim que el nombre màxim de canals que l’amplificador admet en les condicions
d’ajust de nivell de sortida especificat és superior al nombre de canals presents en les bandes
IV i V, per tant com a previsió de futur és més que suficient.
3.2.B.- Distribució de radiodifusió sonora i televisió per satèl·lit
La instal·lació a realitzar en l’edifici objecte d’aquest apartat, no incorpora elements de
captació d’aquest senyal. No obstant, si posteriorment es vol instal·lar una d’aquestes
antenes es pot fixar a la base de la torreta de les antenes de UHF i FM.
Es detallen a continuació, en els apartats següents, els càlculs de les instal·lacions i els
elements necessaris per a la realització de les mateixes, tenint en comte que l’objectiu
principal serà la distribució a l’edifici.
3.2.B.a.-Selecció de l’emplaçament i paràmetres de les antenes receptores del senyal de satèl·lit
El guany de l’antena (i per tant el diàmetre) es calculen a partir de la qualitat de recepció
desitjada, és a dir, la relació C/N a la sortida del convertidor. En els sistemes de radiodifusió
per satèl·lit cal tenir en compte la contribució de la temperatura de soroll de l’antena:
( )1·0 −+= sisa fTTT
La temperatura de soroll equivalent de l’antena depèn de diversos factors, com el lloc
d’emplaçament de l’antena, l’angle d’elevació sobre el pla de terra, les característiques de
l’antena, etc.
Per a una instal·lació com la mostrada en la figura següent, de la qual l’esquema
respon al de la instal·lació tractada:
059.3/10 25/01/2010
28
Per calcular fsis cal tenir en compte la contribució tant del convertidor (LNB) com de
l’amplificador d’FI i la xarxa de distribució de l’edifici. Aplicant la fórmula d’associació de
quadripols en cascada s’obté la següent expressió:
1211
21 ·
·)1()1(
agg
Ag
fff MAX
sis−
+−
+=
on: fsis: factor de soroll del sistema.
f1: factor de soroll del convertidor.
f2: factor de soroll de l’amplificador d’FI.
AMAX: atenuació màxima (a la pitjor presa i a la freqüència més alta).
g1: guany del convertidor.
g2: guany de l’amplificador d’FI.
Normalment, el factor de soroll del sistema és pràcticament igual al factor de soroll de l’LNB,
ja que presenta un valor molt baix.
La potència de soroll (N) a l’entrada del receptor serà:
BTKN ··=
I la potència de la portadora rebuda per l’antena ( C ) de l’enllaç descendent d’un satèl·lit
serà:
⎟⎠⎞
⎜⎝⎛++=
DGPIREC
πλ
4·log20
A partir d’aquestes dues equacions, el càlcul de la relació C/N resulta immediat:
059.3/10 25/01/2010
29
( )BTKD
GPIREdBNC ···log104
·log20)(/ −⎟⎠⎞
⎜⎝⎛++=πλ
on: PIRE: Potència Isotròpica Radiada Efectiva en el punt de recepció (dBw).
G: guany de l’antena (dB).
λ: longitud d’ona (m).
D: distància al satèl·lit (m). Es pren D= 38136 Km.
T: temperatura equivalent de soroll del conjunt LNB i antena.
K: constant de Boltzman. K=1,38·1023 w/Hz·ºK.
B: ample de banda del filtre receptor d’FI.
La PIRE representa la potència que hauria de radiar una antena isotròpica (intensitat de
radiació igual en totes direccions) per obtenir en un punt determinat de l’espai, la mateixa
excitació que aconseguim amb l’antena del satèl·lit.
La PIRE la faciliten els operadors mitjançant els plànols de cobertura de cada satèl·lit. A partir
del valor obtingut als plànols i l’equació anterior es calcula el guany que ha de presentar
l’antena.
El factor de qualitat G/T (dB/ºK) indica el compromís entre el guany de l’antena i el soroll del
receptor. Es recomana un valor d’aquest paràmetre superior a 11 dB, i es defineix com:
)(º·log10)()(/ KTdBGdBTG −=
A partir del guany calculat anteriorment cal trobar el diàmetre de l’antena que cal instal·lar.
Per fer-ho cal seguir el següent procediment:
2
)···4(λπ eS
G r=
on Sr: àrea efectiva de l’antena.
e: eficiència de l’antena.
Per altra banda, si considerem que l’àrea efectiva de l’antena és un cercle podem afirmar
que:
⎟⎟⎠
⎞⎜⎜⎝
⎛=
eGd ·
πλ
Si aïllem el valor de guany (G) en funció del diàmetre de l’antena i substituïm el resultat a
l’equació de C/N (dB), fixant una relació C/N determinada (normalment de 17 o 18 per
059.3/10 25/01/2010
30
compensar les pèrdues d’envelliment del sistema, pèrdues per desapuntament de l’antena,
etc.) i la PIRE en el punt de recepció, podem obtenir el diàmetre de l’antena que caldrà
instal·lar de forma ràpida.
L’orientació de les antenes es determina segons els angles d’elevació (Eº) i d’azimut (Aº),
que depenen de la longitud i latitud de d’indret, longitud del satèl·lit i la relació entre el radi
de la terra i el de l’òrbita del satèl·lit.
Les expressions que determinen aquests angles són les següents:
ββ
sin)15127,0(cosº −
=arctgE
⎟⎟⎠
⎞⎜⎜⎝
⎛+=
ϕδ
sinº180º tgarctgA
on δ: longitud de l’emplaçament de l’antena – longitud del satèl·lit.
φ: latitud de l’emplaçament de l’antena.
β: arcos(cos φ·cos δ).
La distància al satèl·lit (D) és:
( )[ ]21
cos1·41999,01·35789 β−+=D (Km)
Totes les dades de cobertura dels satèl·lits, tipus d’antenes, etc., les faciliten els mateixos
operadors de serveis de satèl·lit.
3.2.B.b.-Càlcul dels suports per la instal·lació de les antenes receptores del senyal de satèl·lit
Les antenes receptores per a la captació dels senyals de UHF, radiodifusió sonora i televisió
per satèl·lit (quan aquesta s’instal·li) es fixaran a l’estructura de l’edifici.
3.2.B.c.-Previsió per incorporar els senyals de satèl·lit
El senyal d’FI es distribuirà a través del cable coaxial de baixada habilitat a tal efecte. Cal
tenir en compte que es distribuirà una única polarització d’un únic satèl·lit. Aquesta mesura
es pren per evitar interferències entre canals de diferents satèl·lits o polarització de la
mateixa freqüència.
059.3/10 25/01/2010
31
3.2.B.d.-Mescla dels senyals de radiodifusió sonora i televisió per satèl·lit amb els terrenals
La capçalera de TV terrestre que s’utilitzarà per aquesta instal·lació disposa de la possibilitat
d’incorporar mòduls d’amplificació d’FI i, per tant, també disposa de l’element de mescla
necessari per incorporar els senyals d’FI al cable de baixada.
3.2.B.e.-Amplificadors necessaris Per decidir els nivells d’amplificació necessaris en els senyals de radiodifusió sonora i televisió
per satèl·lit, perquè el nivell del¡ senyal sigui l’adequat en totes i cadascuna de les preses
d’usuari, cal conèixer l’atenuació que introdueix la xarxa de distribució a cada presa d’usuari
o , com a mínim, cal saber els nivells màxim i mínim d’atenuació. El càlcul de l’atenuació que
introdueix la xarxa de distribució, segons l’esquema de la infraestructura descrit en el plànol
nº T-08, dóna el següent resultat:
Atenuació dB Espai Màxima 39,43 Sala Pol.Mínima 19,86 Gimnàs
Per calcular l’amplificació necessària n’hi ha prou realitzant un simple càlcul a partir de
l’atenuació (màxima i mínima) que introdueix la xarxa de distribució i els nivells de senyal
desitjats a la presa d’usuari, que són entre 45 i 70 dBμV per les emissions digitals via satèl·lit
(QPSK-TV).
Com s’ha dit amb anterioritat, en el disseny inicial no es preveu la incorporació dels serveis
de televisió per satèl·lit. Per tant, els càlculs anteriors són els que caldrà tenir en compte en
el cas que es realitzi una ampliació de la instal·lació inicial.
3.2.B.f.-Càlcul dels paràmetres bàsics de la instal·lació
3.2.B.f.1 .- Nivell de senyal a la presa d’usuari en el millor i pitjor cas
Es detallen a continuació els nivells d’atenuació del senyal en la millor i pitjor de les preses
d’usuari, en funció de la freqüència.
PLANTA PB HABITATGE GIMNÀS PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor X Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 0,0 15,0 0,0 0,0 26,0 4,86 19,86
059.3/10 25/01/2010
32
1500 6,08 21,081750 6,63 21,632150 7,46 22,46
PLANTA PB ESPAI SALA POLIVALENT PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 2 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 2,00 15,00 0,00 5,50 59,0 11,03 33,531500 13,81 36,311750 15,05 37,552150 16,93 39,43
Per calcular el nivell de sortida de la central amplificadora de capçalera que volem
aconseguir, n’hi ha prou realitzant un simple càlcul a partir de l’atenuació (màxima i mínima)
que introdueix la xarxa de distribució i els nivells de senyal desitjats a la presa d’usuari, que
són entre 45 i 70 dBμV per les emissions digitals via satèl·lit (QPSK-TV).
Aplicant un marge d’error suficient per assegurar un nivell òptim de senyal a totes les preses
d’usuari, cal ajustar el nivell de senyal a la sortida de la capçalera als següents valors:
Sortida min. capçalera FI 90 dBμV
Amb aquests nivells de la capçalera i els nivells d’atenuació a la millor i pitjor presa, els
nivells de senyal a la millor i pitjor presa seran els següents:
PLANTA Baixa PLANTA Baixa ESPAI Sala Pol. ESPAI Gimnàs PRESA Única PRESA Única FREQ. (MHz) Nivell (dB) FREQ. (MHz) Nivell (dB)
1000 65,64 1000 48,68
1500 62,29 1500 46,23
1750 62,02 1750 45,74
2150 61,21 2150 46,27
3.2.B.f.2 .- Resposta Amplitud/Freqüència
A partir dels nivells d’atenuació a diferents freqüències per la millor i pitjor presa que ja han
estat calculades al començament d’aquest apartat, la resposta amplitud/freqüència és la
següent:
059.3/10 25/01/2010
33
AMPLITUD/FREQÜÈNCIA A LA MILLOR PRESA 2,6 (dB) AMPLITUD/FREQÜÈNCIA A LA PITJOR PRESA 5,9 (dB)
3.2.B.f.3 .- Càlcul de l’atenuació des dels amplificadors de capçalera fins les preses d’usuari, a la banda de 950 a 2150 MHz.
Es relacionen a continuació els valors calculats d’atenuació en les preses d’usuari per a
tota la xarxa, des dels amplificadors de capçalera fins a la pròpia presa, per a la banda de
950 a 2150 MHz
Els valors han estat obtinguts mitjançant la fórmula:
At (total) = Ai (mescladors MATV/FI) + Σat(cables)+Ad(distribuïdor) +
Ai(derivadors anteriors)+Ad (derivador)+Ai(PAU)+Ai(BAT)
Tenint en compte la fórmula per calcular l’atenuació total des de la capçalera fins a cada
presa d’usuari, les atenuacions dels dispositius que composen la xarxa i les atenuacions
del cablejat coaxial, així com la seva distribució i els metres de cablejat fins a cada presa,
indicat a l’esquema d’instal·lació, s’indiquen en l’Annex I del present projecte les
atenuacions totals en totes les preses de cada vivenda.
3.2.B.f.4 .- Relació portadora/soroll
La relació senyal soroll d’usuari referida a l’antena, ve determinada per l’expressió:
C/N (dB) = PIRE (dBW) + Ga (dBi) + 20 log (λ/4πD) – A (dB) – 10 log (k Tsis B)
On:
PIRE = Potència isòtropa radiada aparent del satèl·lit cap a l’emplaçament de
l’antena:
PIRE (Hispasat) = 52 dBW PIRE (Astra) = 50 dBW
Ga = Guany de l’antena receptora:
Ga (Hispasat) = 41 dBi (a 11.7 GHz) Ga (Astra) = 41.5 dBi (a 11 GHz)
λ = longitud d’ona de les senyals
D = distància de l’emplaçament als satèl·lits
059.3/10 25/01/2010
34
D (Hispasat) = 38452.9 km D (Astra) = 38005.2 km
A = factor d’atenuació degut als agents atmosfèrics (1.8 dB)
k = constant de Boltzman = 1.38 x 10-23 W/HzºK
B = Ample de banda considerat al filtre receptor d’FI:
FM-TV (B = 27 MHz) QPSK-TV (B = 36 MHz)
Tsis = temperatura de soroll del conjunt del sistema en ºK
N = potència de soroll referida a la sortida de l’antena:
N = 10 log (k Tsis B) = -134.909 dBW per FM-TV
N = 10 log (k Tsis B) = -133.660 dBW per QPSK-TV
En l’apartat 3.2.B.a, per a la determinació de les antenes de les instal·lacions de satèl·lit,
s’han utilitzat els valors mínims de la relació C/N que havia de complir la instal·lació en la
presa d’usuari, i el càlcul s’ha realitzat per a les pitjors condicions. En la taula que hi ha
continuació s’indiquen els valors calculats per la relació C/N en les preses d’usuari, prenent
les dades reals de les instal·lacions realitzades per ambdós satèl·lits.
En qualsevol dels casos, les instal·lacions realitzades romandran dins de lo establert en
l’apartat 4.5 de l’Annex I, del Real Decret 401/2003, del 4 d’abril, del Ministeri de Ciència i
Tecnologia, en el qual s’especifica que els nivells de relació portadora – soroll mínim en la
presa d’usuari, pels tipus de modulació utilitzats són:
C/N (dB) FM-TV ≥ 15 dB
C/N (dB) QPSK-TV ≥ 11 dB
3.2.B.f.5 .- Intermodulació En l’actualitat no existeixen expressions contrastades que permetin calcular els nivells de
intermodulació de tercer ordre, produïts en l’amplificació en banda ampla de diversos
senyals, amb modulació digital del tipus utilitzat en les senyals de satèl·lit:
QPSK-TV, FM-TV, etc. Les següents expressions serviran com a aproximació, pels càlculs del
nivell d’interferència dels productes de intermodulació en les senyals de satèl·lit.
El valor de la relació entre qualsevol de les portadores i els productes de intermodulació
múltiple produïts per “n” canals, en un amplificador de banda ampla ve donat per l’expressió:
C/XM = C/Xmref + 2 (Smax amp – S amp) – 15 log (n-1)
059.3/10 25/01/2010
35
On:
C/XM = relació portadora – productes de intermodulació simple.
C/Xmref = valor de referència de la relació portadora – productes de intermodulació
múltiple a la sortida de l’amplificador, pel nivell de sortida màxim del mateix, quan
només s’amplifiquen dos canals (60 dB a la majoria d’amplificadors).
Smax amp = nivell màxim de sortida de l’amplificador pel qual s’especifica C/Xmref.
S amp = valor de la senyal de portadora a la sortida de l’amplificador.
n = nombre de canals que ha d’amplificar la central.
En el cas que s’instal·li una antena parabòlica, cal tenir en comte els efectes combinats en la
intermodulació del LNB i de l’amplificador FI-SAT. El mòdul LNB degut als nivells tan baixos
de senyal amb els que ha de treballar, pot dissenyar-se amb molt alt guany i uns índex de
linealitat molt elevats, pel que el seu comportament davant els productes de intermodulació
produïts a la seva sortida serà sempre millor que el de l’amplificador FI-SAT.
Realitzant un càlcul absolutament pessimista, i suposant que el valor de C/XM del LNB fos
igual que el de l’amplificador de FI-SAT, el valor de la relació entre qualsevol de les
portadores i els productes de intermodulació múltiple produïts per “n” canals, en la cascada
formada pel LNB i l’amplificador FI-SAT, ve donada per l’expressió:
⎥⎥⎥
⎦
⎤
⎢⎢⎢
⎣
⎡
+−=⎟⎠⎞
⎜⎝⎛
⎟⎟⎠
⎞⎜⎜⎝
⎛−⎟⎟⎠
⎞⎜⎜⎝
⎛−
20202
1010·log20XMc
XMc
TXMC
On:
C/XMT = relació portadora – productes de intermodulació múltiple total.
C/XM1 = relació portadora – productes de intermodulació múltiple del LNB.
C/XM2 = relació portadora – productes de intermodulació múltiple de l’amplificador
FI-SAT.
Els valors que compleixen amb el que està establert en l’apartat 4.5 de l’Annex I, del Real
Decret 401/2003, del 4 d’abril, del Ministeri de Ciència i Tecnologia, són els següents:
FM-TV ≥ 27 dB
QPSK-TV ≥ 18 dB
059.3/10 25/01/2010
36
En el disseny inicial de la instal·lació, no es preveu la incorporació de serveis de televisió per
satèl·lit. El càlcul final d’aquest paràmetre dependrà del nivell màxim de sortida de
l’amplificador escollit per amplificar els senyals d’FI-SAT.
3.2.B.g.-Descripció dels elements components de la instal·lació
3.2.B.g.1 .- Sistemes de captació En el disseny inicial de la instal·lació, no es preveu la incorporació de serveis de televisió per
satèl·lit.
3.2.B.g.2 .- Amplificadors En el disseny inicial de la instal·lació, no es preveu la incorporació de serveis de televisió per
satèl·lit.
3.2.B.g.3 .- Materials complementaris En el disseny inicial de la instal·lació, no es preveu la incorporació de serveis de televisió per
satèl·lit.
059.3/10 25/01/2010
37
3.2.C.- Accés i distribució del Servei de Telefonia
En aquest capítol es dimensiona i detalla, el disseny i topologia de la infraestructura d’accés i
distribució al servei de telefonia, per l’edifici. Es considera únicament l’accés dels usuaris al
servei telefònic bàsic.
3.2.C.a.-Establiment de la Topologia i Infraestructura de la xarxa La xarxa interior de l’edifici és el conjunt de conductors, elements de connexió i equips actius
que és necessari instal·lar per establir la connexió entre el d’interconnexió (Armari de
Telecomunicacions) i la xarxa exterior d’alimentació, del servei de telefonia disponible al
públic.
El punt de Interconnexió estarà situat en l’armari de Instal·lacions.
La totalitat de la xarxa, per tant, es divideix en un únic tram que és la xarxa d’alimentació.
Xarxa d’alimentació: s’introdueix en la Infraestructura de l’edifici a través de l’arqueta
d’entrada i de la canalització externa fins el registre d’interconnexió, on es troba el punt
d’entrada general, i d’on parteix la resta de la xarxa de distribució.
El disseny i dimensionament de la xarxa d’alimentació així com la seva realització, seran
responsabilitat dels Operadors del servei de telefonia disponible al públic que accedeixin a
l’edifici.
Es descriuen a continuació les funcionalitats del Punt d’interconnexió (Punt de
Terminació de Xarxa): Realitza la unió entre les xarxes d’alimentació de les Operadores
del servei i la de distribució de la Infraestructura de l’edifici, i delimita les responsabilitats en
quant a manteniment entre l’operador del servei i la propietat de l’edifici.
Els parells de les xarxes d’alimentació finalitzen en una regletes de connexió (regletes
d’entrada), que seran independents per a cada Operador del servei. Aquestes regletes
d’entrada seran instal·lades per aquests Operadors. Els parells de la xarxa de distribució
finalitzen en altres regletes de connexió (regletes de sortida), que seran instal·lades per la
propietat de l’edifici segons lo especificat en aquest projecte. El número total de parells (per
a tots els operadors del servei) de les regletes d’entrada, serà 1.5 vegades el número de
parells de les regletes de sortida. La unió entre les dues regletes es realitza mitjançant fils –
pont.
059.3/10 25/01/2010
38
3.2.C.b.-Càlcul i dimensionament de la xarxa i tipus de cables.
El dimensionament de la xarxa i dels tipus de cable necessaris, es realitza de forma tal que la
xarxa interior de l’edifici sigui capaç d’atendre a la demanda telefònica a llarg termini. Per
això, la demanda prevista és de:
Nombre de parells 5
Aquests parells estaran connectats a les regletes de sortida del Punt d’interconnexió dins el
registre a l’armari d’instal·lacions.
D’aquest punt sortirà cada un dels cables que arribaran a cadascun dels punts de distribució.
059.3/10 25/01/2010
39
3.2.D.- Canalització i infraestructura de distribució
S’exposa a continuació l’estudi de les canalitzacions i infraestructures de distribució de
l’edifici i el càlcul de tots els elements que la constitueixen: arquetes, recinte, canalitzacions i
registres.
3.2.D.a.-Arqueta d’entrada i canalització externa
L’arqueta d’entrada és el recinte que permet establir la unió entre les xarxes d’alimentació
dels serveis de telecomunicació dels diferents operadors i la infraestructura de
telecomunicacions de l’edifici. Es troba a la zona exterior de l’edific i en ella conflueixen per
un costat les canalitzacions dels diferents operadors i per l’altre directament la canalització
d’enllaç exterior de la infraestructura de l’edifici.
Arqueta entrada (long./amplada/prof.) 400 x 400 x 600 mm
La ubicació de l’arqueta d’entrada es pot veure al plànol T-05.
La canalització externa soterrada que va des de l’arqueta d’entrada fins a l’armari
d’instal·lacions estarà constituïda per 3 tubs de 63 mm de diàmetre exterior dins un prisma
de formigó, amb la següent ocupació:
DIMENSIONAMENT 3 Tubs 63 mm.∅
UTILITZACIÓ 1 tub per TB,XDSI i xDSL
059.3/10 25/01/2010
40
1 tub per TLCA
1 tubs de reserva
3.2.D.b.-Canalització d’enllaç superior i inferior
La canalització d’enllaç inferior és la que suporta els cables de la xarxa d’alimentació des
del punt d’entrada general fins el registre principal ubicat a l’armari d’instal·lacions.
Aquesta canalització és la que dóna continuïtat a la canalització externa a través del punt
d’entrada general, i per tant el seu dimensionament i utilització és el mateix:
DIMENSIONAMENT 4 Tubs 63 mm.∅
UTILITZACIÓ 1 tub per TB,XDSI i xDSL
1 tub per TLCA
2 tubs de reserva
La canalització d’enllaç superior és la que suporta els cables que van des dels sistemes
de captació fins al registre de telecomunicacions de capçalera. Els cables aniran amb
protecció mitjançant un tub o canalització entre elements de captació (antenes) i el registre,
mitjançant tubs de 40 mm. de diàmetre i de paret interior llisa.
3.2.D.c.-Registre de telecomunicacions de capçalera
S’ha previst per l’edifici un Registre de Telecomunicacions. A continuació s’en pot veure una
descripció.
3.2.D.c.1 .- Registre
El registre serà un habitacle o armari on s’instal·laran els elements d’amplificació i distribució
dels senyals provinents de les antenes.
059.3/10 25/01/2010
41
DIMENSIONS REGISTRE (long./amplada/prof.) 450 x 450 x 300 mm
3.2.D.c.2 .- Equipament dels registre
S’habilitarà una canalització elèctrica des de l’armari d’instal·lacions fins al registre,
constituïda per cables de coure amb aïllament de fins 750V i de 2x6 + T mm2 de secció.
Aquests cables aniran a l’interior d’un tub de 32 mm de diàmetre.
Aquesta canalització s’iniciarà mitjançant les proteccions elèctriques mínimes que s’indiquen
a continuació, així com una previsió per la seva ampliació en un 50%:
- Interruptor magnetotèrmic de tall general per a l’enllumenat i endolls: tensió
nominal mínima de 230/400 Vca, intensitat nominal de 25A i poder de tall de 6KA.
- Interruptor diferencial de tall omnipolar per a l’enllumenat i endolls: tensió
nominal mínima de 230/400 Vca, freqüència 50-60 Hz, intensitat nominal de 25A,
intensitat de defecte de 30mA, de tipus selectiu i resistència de curtcircuit de 6
KA.
En el registre es disposarà d’unes bornes apropiades per a la connexió del cable de terra.
En el registre hi haurà, una bases d’endoll amb presa de terra i de capacitat mínima de 16A.
3.2.D.d.-Registres de pas
Els registres de pas són elements que faciliten l’escomesa de cables.
Les dimensions d’aquests registres seran de 200x200x100 mm.
Òdena, 25 de Gener de 2010
Marc Guitart i Garcia Enginyer Tècnic de Telecomunicació
(Especialitat en Imatge i So) Col·legiat Num. 10.460
059.3/10 25/01/2010
42
4.- PLÀNOLS
059.3/10 25/01/2010
43
Els plànols que s’inclouen a continuació són els descriptius de tota la infraestructura
projectada en aquest apartat.
A continuació hi ha una relació detallada de tots els plànols que s’inclouen:
Plànol Descripció
T-01 Cablejat Estructurat (Infraestructura) Planta Baixa
T-02 Cablejat Estructurat (Infraestructura) Planta Primera
T-03 Cablejat Estructurat (Cablatge) Planta Baixa
T-04 Cablejat Estructurat (Cablatge) Planta Primera
T-05 Infraestructura Radio/Televisió Planta Baixa
T-06 Infraestructura Radio/Televisió Planta Primera
T-07 Infraestructura Radio/Televisió Planta Coberta
T-08 Esquema Infraestructura Radio/Televisió
059.3/10 25/01/2010
52
5.- PLEC DE CONDICIONS
059.3/10 25/01/2010
53
Aquest plec de condicions té efecte sobre l’execució de totes les obres que comprèn aquest
projecte.
Les condicions que s’exigeixen en aquest plec de condicions són les mínimes acceptables en
la realització del Cablejat Estructurat i Infraestructura de Telecomunicacions d’aquest edifici.
En el cas que existeixi la figura del director d’obra de telecomunicacions representada per un
enginyer o enginyer tècnic de telecomunicacions, qualsevol decisió d’aquest haurà de ser
executada en els termes que aquest determini en el llibre d’ordres i visites fins al moment de
la recepció de l’obra acabada.
La present especificació pot ser modificada i ampliada per les condicions del contracte o per
les especificacions particulars.
5.1.- CABLEJAT ESTRUCTURAT A la realització de la instal·lació objecte del Plec present, es consideraran d'aplicació totes
aquelles normatives que legalment ho siguin a la data d'adjudicació de la contracta.
Així mateix hauran de complir-se les Normes citades a cadascun dels apartats específics de
la instal·lació del Plec de Condicions, sense que aquesta relació sigui excloent de la resta de
Normatives de caràcter general.
Si existís una Norma d'aplicació que per qualsevol motiu no fos recollit en el present
Projecte, és obligació del Contractista avisar-ho a la Direcció d'Obra, i solucionar-ho sense
que es pugui, per aquesta causa, incrementar el pressupost, siguin quines siguin les
despeses que per això es veiés obligat a realitzar el contractista.
5.1.A.- Documentació prèvia a l'inici de les obres Un cop adjudicada l'obra definitivament i abans de la instal·lació, el contractista presentarà al
Tècnic encarregat els catàlegs i cartes, mostres, certificats de garantia, etc dels materials que
s'utilitzaran.
Abans d'instal·lar qualsevol material, s'haurà de presentar el següent:
• Certificats amb totes les característiques i dimensions de l'element o sistema que
figuren en aquest Plec de Condicions.
059.3/10 25/01/2010
54
• Protocols d'assaig dels materials firmats pel fabricant o pel laboratori oficialment
competent en el tema del que es tracti.
• No es podran usar materials sense que prèviament hagin estat acceptats per la
Direcció d'Obra.
• Aquest control previ no constitueix recepció definitiva i per tant, els materials poden
ésser rebutjats per la Direcció de l'Obra, fins i tot després de ser col·locats, si no
complissin les condicions exigides en aquest Plec, podent ser reemplaçats per altres
que compleixin les mencionades qualitats.
• Els materials rebutjats per la Direcció d'Obra hauran de ser retirats pel contractista
immediatament i en la seva totalitat. De no complir-se aquesta condició, la Direcció
podrà ordenar retirar-los pel medi que consideri escaient, a càrrec de la Contracta.
• Tots els materials i elements estaran en perfecte estat de conservació i ús i es
rebutjaran aquells que estiguin espatllats i amb defectes o malmesos.
• Els materials i elements a emprar, les característiques dels quals no s'especifiquen
expressaments en aquest Plec de Condicions, seran dels tipus i qualitats que utilitzi
normalment l'Empresa suministradora del fluït i previ vist i plau del Director d'Obra.
• Tots els elements d'un determinat tipus a utilitzar seran de la mateixa marca i model.
5.1.B.- Condicions generals
El sistema de cablejat estructurat complirà la norma europea EN50173-1:2002 que recull
tots els requeriments del disseny, execució i certificació del cablejat estructurat en edificis.
Pel que fa a la categoria del cablejat, tots els cables, connectors i panells compliran la
categoria 6, conformant enllaços i canals de Classe E, que especifica les característiques de
transmissió fins a 250 MHz.
El cable serà trenat sense apantallar (UTP) de 4 parells 23 AWG, 100 ohms d’impedància
característica, categoria 6/Classe E de la marca AMP/Tyco amb coberta LSZH.
El cable i els diferents accessoris que conformen el conjunt de la instal·lació seran d’un
material lliure d’halògens, amb baixa emissió de fum (LSZH) i amb piroretardants.
La instal·lació i certificació es realitzarà per personal tècnic qualificat pel fabricant del sistema
de cablejat i el seu període de garantia no serà inferior a 15 anys.
059.3/10 25/01/2010
55
La llargada màxima de cablejat d’un punt, considerada des del panell a la presa d’usuari, en
cap cas podrà superar la distància de 90m. La distància màxima d’un canal, incloent els
fuetons de les dues bandes, en cap cas podrà superar la distància de 100m.
Es tindrà en compte la Normativa Europea sobre compatibilitat Electromagnètica:
EN 55022 sobre Emissió de Radiacions Electromagnètiques
EN 55024 sobre Sensitivitat a Radiacions Electromagnètiques
EN 55082 sobre Immunitat a Radiacions Electromagnètiques
Igualment caldrà complir la normativa sobre protecció contra incendis:
IEC 332 sobre propagació d´incendis
IEC 754 sobre emissió de gasos tòxics
IEC 1034 sobre emissió de fum
5.1.C.- Prescripcions tècniques
5.1.C.a.-Armaris
El Rack R0 serà una caixa de xarxa mural Rittel QuickBox de 21U de dimensions 600x600 o
un model equivalent d’un altre fabricant amb prestacions iguals o superiors.
Material:
• Placa de muntatge mural amb angles de muntatge de xapa d'acer de 2.0mm
• Coberta de xapa d'acer de 1.0 mm
• Porta transparent amb marc de xapa d'acer i cristall de seguretat ESG de 3mm
• superfície caixa: texturitzat, RAL 703
Unitat d'envàs, peça mural:
• angle de muntatge premuntat, escombreta per a l'entrada de cables dalt/baix
• guia d'entrada de cables
Unitat d'envàs, coberta:
• composta per un terra i un sostre amb ranures de ventilació
• escombreta per l'entrada de cables dalt/baix
059.3/10 25/01/2010
56
• 2 tanques de seguretat als laterals
• portes amb tanques de seguretat
• guies de perfil de 19" ajustables en profunditat sense escalonaments
5.1.C.b.-Cables
Tots els canals de comunicacions de coure del Sistema de Cablejat Estructurat seran de
Classe E/Categoria 6. És precís assegurar el compliment de la Categoria 6/Classe E amb total
certesa.
Els equips de test tenen un rang d'exactitud, arreplegat en els estàndards, en el que poden
donar un "Fals Positiu" o "Fals Negatiu". Veure requisits, procediments de test i fórmules en
ANSI/TIA/EIA-568-B.2 o consultar amb un fabricant d'equips de test.
Per a evitar obtenir mesures en el rang d'incertesa, que poden resultar incorrectes en
diversos dBs, és necessari disposar de canals de cablatge amb prestacions superiors a allò
que s'ha arreplegat en l'estàndard, els mesures del qual estiguin fora del mencionat rang
d'incertesa.
Els canals de Classe E/Categoria 6 permetran l'ús de 4 connexions mascle-femella amb un
marge NEXT mínim garantit de 6 dB, i 6 connexions mascle-femella amb un marge NEXT
mínim garantit de 4 dB.
No s'admetran en la definició de prestacions els valors típics o mitjans, ja que no asseguren
el funcionament correcte del sistema instal·lat.
El sistema en el seu conjunt ha de complir o millorar les Prestacions Garantides del Canal de
Categoria 6 amb 4 connexions.
5.1.C.c.-Encaminador/Router
Es proposa governar la xarxa telemàtica amb un encaminador de la sèrie Cisco 1900. En
concret el model Cisco 1941/K9 o equivalent, amb dos ports Gigabit Ethernet, 2 ranures
d'ampliació EHWIC, 1 ranura d'ampliació ISM, 256MB CF, 512 DRAM.
Especificacions:
Embedded hardware-based crypto acceleration (IPSec + Yes
059.3/10 25/01/2010
57
SSL)
Total Onboard LAN 10/100/1000 2
RJ-45-Based Ports 2
SFP-Based Ports 0
SM Slots 0
Double-Wide SM Slots 0
EHWIC Slots 2
Double-Wide EHWIC slots (use of a double-wide EHWIC slot will consume two EHWIC slots)
1
ISM Slots 1 (0 on the Cisco 1941W)
Memory (DDR2 Error Correction Code [ECC] ECC DRAM) - Default
512 MB
Memory (DDR2 ECC DRAM) - Maximum 2.0 GB
Compact Flash (external) - Default slot 0: 256 MB
slot 1: none
Compact Flash (external) - Maximum slot 0: 4 GB
slot 1: 4 GB
External USB flash memory slots (Type A) 2
USB Console Port (Type B) (up to 115.2 kbps) 1
Serial Console Port (up to 115.2 kbps) 1
Serial Auxiliary Port (up to 115.2 kbps 1
Power Supply Options AC, POE
Redundant Power Supply Support No
Power Specifications
AC Input Voltage 100-240 V ~
AC Input Frequency 47-63 Hz
AC Input Current range AC Power Supply (Max) (Amps) 1.5-0.6
AC Input Surge Current <50 A
Typical Power (No Modules) 35 W
Maximum Power capacity with AC power supply 110 W
Maximum Power capacity with PoE power supply (platform only)
110 W
059.3/10 25/01/2010
58
Maximum PoE device power capacity with PoE power supply
80 W
Physical Specifications
Dimensions (H x W x D) 3.5 in x 13.5 in x 11.5 in
Rack Height 2 RU
Rack-mount 19in. (48.3 cm) EIA Included
Wall-mount (refer to installation guide for approved orientation)
Yes
Weight-with AC power supply (no modules) 12 lbs
Weight-with POE power supply (no modules) 12.8 lbs
Maximum Weight-Fully Configured 14 lbs
Airflow Front to Side
Environmental Specifications
Operating Condition Temperature-5906 feet (1800 m) max. altitude 0-40°C (32-104°F)
Temperature-9843 feet (3000 m) max. altitude 0-25°C (32-77°F)
Altitude 3000 m (10000 ft)
Humidity 10 to 85% RH
Acoustic: Sound Pressure (Typ/Max) 26/46 dBA
Acoustic: Sound Power (Typ/Max) 36/55 dBA
Transporation/Storage Condition
Temperature -40 - 70 oC (-40 - 158 oF)
Humidity 5 to 95%RH
Altitude 4570m (15000 ft)
Regulatory Compliance
Safety UL 60950-1
CAN/CSA C22.2 No. 60950-1
EN 60950-1
AS/NZS 60950-1
059.3/10 25/01/2010
59
IEC 60950-1
EMC 47 CFR, Part 15
ICES-003 Class A
EN55022 Class A
CISPR22 Class A
AS/NZS 3548 Class A
VCCI V-3
CNS 13438
EN 300-386
EN 61000 (Immunity)
EN 55024, CISPR 24
EN50082-1
Telecom TIA/EIA/IS-968
CS-03
ANSI T1.101
ITU-T G.823, G.824
IEEE 802.3
RTTE Directive
5.1.C.d.-Commutador/Switch S'instal·larà un commutador de la sèrie Cisco Catalyst 2960 amb 48 ports Gigabit Ethernet,
quatre dels quals son duals. En concret el model Cisco Catalyst 2960G-48TC-L o equivalent.
Característiques
• 44 connexions Ethernet 10/100/1000 i 4 connexions duals (cada connexió dual té una
conexió Ethernet 10/100/1000 i un port SF Gigabit Ethernet, amb un sol port actiu)
• configuració fixa en 1 RU
059.3/10 25/01/2010
60
Especificacions principals
Description Specification
Performance • 16 Gbps switching fabric (Catalyst 2960PD-8TT-L , Catalyst 2960-8TC-L, Catalyst 2960-24TT-L, Catalyst 2960-24TC-L, Catalyst 2960-24LT-L, Catalyst 2960-24PC-L, Catalyst 2960-48PST-L, Catalyst 2960-48TT-L, Catalyst 2960-48TC-L)
• 32 Gbps switching fabric (Catalyst 2960G-8TC-L, Catalyst 2960G-24TC-L, Catalyst 2960G-48TC-L)
• Forwarding rate based on 64-byte packets:
• Catalyst 2960G-48TC-L: 39.0 Mpps
• 64 MB DRAM
• 32 MB flash memory
• Configurable up to 8000 MAC addresses
• Configurable up to 255 IGMP groups
• Configurable maximum transmission unit (MTU) of up to 9000 bytes, with a maximum Ethernet frame size of 9018 bytes (Jumbo frames) for bridging on Gigabit Ethernet ports, and up to 1998 bytes for bridging of Multiprotocol Label Switching (MPLS) tagged frames on both 10/100 and 10/100/1000 ports
Connectors and Cabling
• 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling
• 100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling
• 1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
• 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling
• 1000BASE-SX, -LX/LH, -ZX, -BX and CWDM SFP-based ports: LC fiber connectors (single/multimode fiber)
• 100BASE-LX, -BX, -FX: LC fiber connectors (single/multimode fiber).
Power Connectors
• Customers can provide power to a switch by using either the internal power supply or the Cisco RPS 675. The connectors are located at the back of the switch.
059.3/10 25/01/2010
61
• Internal-Power-Supply Connector
• The internal power supply is an autoranging unit.
• The internal power supply supports input voltages between 100 and 240VAC.
• Use the supplied AC power cord to connect the AC power connector to an AC power outlet.
• Cisco RPS Connector
• The connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.
• The connector offers a 2300W redundant power system that supports up to six external network devices and provides power to two failed devices at a time.
• The connector automatically senses when the internal power supply of a connected device fails and provides power to the failed device, preventing loss of network traffic.
• Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-system receptacle.
Indicators • Per-port status: Link integrity, disabled, activity, speed, full-duplex
• System status: System, RPS, link status, link duplex, link speed
Dimensions (H x W x D)
• Cisco Catalyst 2960G-48TC-L: 1.73 x 17.5 x 12.9 in. (4.4 x 44.5 x 32.8 cm)
Weight • Cisco Catalyst 2960G-48TC-L: 12 lb (5.4 kg)
Environmental Ranges
Normal Operating Conditions:
• -5ºC to +45ºC, up to 5,000 feet (1500 m)
• -5ºC to +40ºC, up to 10,000 feet (3000 m)
• -5ºC to +35ºC, up to 13,000 feet (4000 m)
Short-Term* Exceptional Operating Conditions:
• -5ºC to +55ºC, at sea level
• -5ºC to +50ºC, up to 5,000 feet (1500 m)
• -5ºC to +45ºC, up to 10,000 feet (3000 m)
059.3/10 25/01/2010
62
• -5'C to +40'C, up to 13,000 feet (4000 m)
* Not more than following in one year period: 96 consecutive hours, or 360 hours total, or 15 occurrences
* For Catalyst 2960G-8TC-L, reduce the high range temperature by 5°C
Acoustic Noise • ISO 7779: Bystander position operating to an ambient temperature of 25°C
• Cisco Catalyst 2960G-48TC-L: 43 dBa
Mean Time Between Failure (MTBF)
• Cisco Catalyst 2960G-48TC-L: 221,432 hrs
AC Input Voltage and Current
• DC input, 48 VDC, 0.3A (Cisco Catalyst 2960PD-8TT-L),
• (For AC input, use PWR-A= sold separately)
• 100-240VAC (autoranging), 3.0-1.5A, 50-60 Hz (Cisco Catalyst 2960G-24TC-L and Catalyst 2960G-48TC-L)
Power Rating • Cisco Catalyst 2960G-48TC-L: 0.140kVA
5.1.C.e.-Punts d’accés sense fil (APs) El punt d’accés sense fil proposat és de la sèrie Aironet 1140 de la marca Cisco, i en concret
el model AIR-LAP1142N-E-K9-Dual-band, per a controlador extern, 802.11a/g/n o equivalent.
Característiques:
Certificat per a la seva operació a l’Estat Espanyol.
Draft 802.11n Versio 2.0:
• 2x3 multiple-entrada, multiple sortida (MIMO) amb dos canals espacials
• Maximal ratio combining (MRC)
• Canals de 20-MHz and 40-MHz
• Velocitats de transmissió PHY de fins a 300 Mbps
• Agregació de paquets: A-MPDU (Tx/Rx), A-MSDU (Tx/Rx)
• 802.11 amb sel·lecció de freqüència dinàmica (DFS) (Bin 5)
• Suporta Cyclic shift diversity (CSD)
059.3/10 25/01/2010
63
Velocitats de transmissió suportades
802.11a: 6, 9, 12, 18, 24, 36, 48, i 54 Mbps
802.11g: 1, 2, 5.5, 6, 9, 11, 12, 18, 24, 36, 48, i 54 Mbps
802.11n data rates (2.4 GHz and 5 GHz):
MCS Index1
GI2 = 800ns GI = 400ns
20-MHz Rate (Mbps)
40-MHz Rate (Mbps)
20-MHz Rate (Mbps)
40-MHz Rate (Mbps)
0 6.5 13.5 7.2 15
1 13 27 14.4 30
2 19.5 40.5 21.7 45
3 26 54 28.9 60
4 39 81 43.3 90
5 52 108 57.8 120
6 58.5 121.5 65 135
7 65 135 72.2 150
8 13 27 14.4 30
9 26 54 28.9 60
10 39 81 43.3 90
11 52 108 57.8 120
12 78 162 86.7 180
13 104 216 115.6 240
14 117 243 130 270
15 130 270 144.4 300
Canals operatius a la zona E (ETSI)
• 2.412 - 2.472 GHz; 13 canals
• 5.180 - 5.320 GHz; 8 canals
• 5.500 - 5.700 GHz, 11 canals
Sensitivitat de recepció
059.3/10 25/01/2010
64
802.11b
-91 dBm @ 1 Mb/s
-91 dBm @ 2 Mb/s
-91 dBm @ 5.5 Mb/s
-88 dBm @ 11 Mb/s
802.11g
-86 dBm @ 6 Mb/s
-86 dBm @ 9 Mb/s
-86 dBm @ 12 Mb/s
-86 dBm @ 18 Mb/s
-85 dBm @ 24 Mb/s
-83 dBm @ 36 Mb/s
-78 dBm @ 48 Mb/s
-77 dBm @ 54 Mb/s
802.11a
-90 dBm @ 6 Mb/s
-90 dBm @ 9 Mb/s
-90 dBm @ 12 Mb/s
-90 dBm @ 18 Mb/s
-88 dBm @ 24 Mb/s
-85 dBm @ 36 Mb/s
-80 dBm @ 48 Mb/s
-79 dBm @ 54 Mb/s
2.4-GHz
802.11n (HT20)
-88 dBm @ MCS0
-87 dBm @ MCS1
-86 dBm @ MCS2
-83 dBm @ MCS3
-80 dBm @ MCS4
-76 dBm @ MCS5
-74 dBm @ MCS6
-73 dBm @ MCS7
-87 dBm @ MCS8
-85 dBm @ MCS9
-83 dBm @ MCS10
-80 dBm @ MCS11
-77 dBm @ MCS12
-73 dBm @ MCS13
-71 dBm @ MCS14
-70 dBm @ MCS15
2.4-GHz
802.11n (HT40)
-85 dBm @ MCS0
-85 dBm @ MCS1
-83 dBm @ MCS2
-80 dBm @ MCS3
-77 dBm @ MCS4
-72 dBm @ MCS5
-71 dBm @ MCS6
-70 dBm @ MCS7
-85 dBm @ MCS8
-82 dBm @ MCS9
-80 dBm @ MCS10
-76 dBm @ MCS11
-73 dBm @ MCS12
-69 dBm @ MCS13
-67 dBm @ MCS14
-66 dBm @ MCS15
5-GHz
802.11n (HT20)
-91 dBm @ MCS0
-91 dBm @ MCS1
-90 dBm @ MCS2
-87 dBm @ MCS3
-84 dBm @ MCS4
-79 dBm @ MCS5
-77 dBm @ MCS6
-76 dBm @ MCS7
-90 dBm @ MCS8
-89 dBm @ MCS9
-86 dBm @ MCS10
-83 dBm @ MCS11
-80 dBm @ MCS12
-75 dBm @ MCS13
-74 dBm @ MCS14
-72 dBm @ MCS15
5-GHz
802.11n (HT40)
-78 dBm @ MCS0
-78 dBm @ MCS1
-78 dBm @ MCS2
-78 dBm @ MCS3
-78 dBm @ MCS4
-75 dBm @ MCS5
-73 dBm @ MCS6
-72 dBm @ MCS7
-76 dBm @ MCS8
-76 dBm @ MCS9
-76 dBm @ MCS10
-76 dBm @ MCS11
-76 dBm @ MCS12
-71 dBm @ MCS13
-69 dBm @ MCS14
-68 dBm @ MCS15
059.3/10 25/01/2010
65
Potència Màxima de transmissió
2.4GHz
20 dBm (100 mW)
17 dBm (50 mW)
14 dBm (25 mW)
11 dBm (12.5 mW)
8 dBm (6.25 mW)
5 dBm (3.13 mW)
2 dBm (1.56 mW)
-1 dBm (0.78 mW)
5GHz
20 dBm (100 mW)
17 dBm (50 mW)
14 dBm (25 mW)
11 dBm (12.5 mW)
8 dBm (6.25 mW)
5 dBm (3.13 mW)
2 dBm (1.56 mW)
-1 dBm (0.78 mW)
5.1.C.f.-Controlador xarxa sense fil
Es proposa gestionar la xarxa sense fil amb un controlador de la sèrie Cisco 2100. En concret
el model Cisco 2106, o un un model equivalent que suporti com a mínim 6 punts d'accés i
sigui de la mateixa marca i compatible amb els punts d'accés i la resta d'equips de xarxa
instal·lats.
Característiques: 8 ports ethernet 10/100, instal·lable en rack amb el kit de muntatge
corresponent, compatible amb els estàndards WIFI: IEEE 802.11a, 802.11b, 802.11g,
802.11d, 802.11h, 802.11n.
Seguretat i xifratge:
• Wi-Fi Protected Access (WPA)
• IEEE 802.11i (WPA2, RSN)
• RFC 1321 MD5 Message-Digest Algorithm
• RFC 2104 HMAC: Keyed Hashing for Message Authentication
• RFC 2246 TLS Protocol Version 1.0
• RFC 3280 X.509 PKI Certificate and CRL Profile
059.3/10 25/01/2010
66
• WEP and Temporal Key Integrity Protocol-Message Integrity Check (TKIP-MIC): RC4
40, 104 and 128 bits (both static and shared keys)
• Secure Sockets Layer (SSL) and Transport Layer Security (TLS): RC4 128-bit and RSA
1024- and 2048-bit
• Advanced Encryption Standard (AES): CCM, Counter Mode with Cipher Block Chaining
Message Authentication Code Protocol (CCMP)
• WEP and Temporal Key Integrity Protocol-Message Integrity Check (TKIP-MIC): RC4
40, 104 and 128 bits (both static and shared keys)
• Secure Sockets Layer (SSL) and Transport Layer Security (TLS): RC4 128-bit and RSA
1024- and 2048-bit
• Advanced Encryption Standard (AES): CCM, Counter Mode with Cipher Block Chaining
Message Authentication Code Protocol (CCMP)
Autentificació i autorització
• IEEE 802.1X
• RFC 2548 Microsoft Vendor-Specific RADIUS Attributes
• RFC 2716 PPP EAP-TLS
• RFC 2865 RADIUS Authentication
• RFC 2866 RADIUS Accounting
• RFC 2867 RADIUS Tunnel Accounting
• RFC 2869 RADIUS Extensions
• RFC 3576 Dynamic Authorization Extensions to RADIUS
• RFC 3579 RADIUS Support for EAP
• RFC 3580 IEEE 802.1X RADIUS Guidelines
• RFC 3748 Extensible Authentication Protocol
• Web-based authentication
Administració
• SNMP v1, v2c, v3
• RFC 854 Telnet
• RFC 1155 Management Information for TCP/IP-Based Internets
• RFC 1156 MIB
• RFC 1157 SNMP
• RFC 1213 SNMP MIB II
• RFC 1350 TFTP
059.3/10 25/01/2010
67
• RFC 1643 Ethernet MIB
• RFC 2030 SNTP
• RFC 2616 HTTP
• RFC 2665 Ethernet-Like Interface types MIB
• RFC 2674 Definitions of Managed Objects for Bridges with Traffic Classes, Multicast
Filtering, and Virtual LAN Extensions
• RFC 2819 RMON MIB
• RFC 2863 Interfaces Group MIB
• RFC 3164 Syslog
• RFC 3414 User-Based Security Model (USM) for SNMPv3
• RFC 3418 MIB for SNMP
• RFC 3636 Definitions of Managed Objects for IEEE 802.3 MAUs
• Cisco private MIBs
Interficies d'administració
• Designed for use with Cisco Wireless Control System
• Web-based: HTTP/HTTPS individual device manager
• Command-line interface: Telnet, SSH, serial port
Indicadors
• Console port: RS-232 (DB-9 male/RJ-45 connector included)
• Network: Eight 10/100 Mbps Ethernet (RJ-45) including two 802.3af or Cisco PoE
ports rated for use with Cisco Aironet lightweight access points
• LED indicators: Link Activity (each 10/100 port), Power, Status, Alarm, Access Point
Joined
5.1.C.g.-Canals plàstiques Canal plàstica de PVC rígid amb lateral llis, perforat o ranurat, de dimensions 60x190 mm
com a màxim, amb separador o sense i muntada superficialment.
5.1.C.h.-Safates plàstiques
Safata plàstica de PVC rígid llis o perforat, de 60x400 mm de dimensions màximes.
059.3/10 25/01/2010
68
5.1.D.- Condicions d’execució
5.1.D.a.-Sistemes de distribució de corrent elèctrica
S’han de tenir en compte les probes de separació de seguretat d’acord amb la norma IEC
61140 per a freqüències de 50Hz i 60Hz. En cas que els requeriments d’acreditació de
seguretat i EMI siguin conflictius la seguretat sempre tindrà prioritat.
5.1.D.b.-Cables
El cablejat, en arribar a les proximitats del rack, tindrà una llargada lliure mínima de 5 m per
tal de:
- Permetre realitzar una “coca” de 2 m
- Cobrir la distancia entre la paret i el rack
- Pujar a la part superior del rack
- Reservar un marge de seguretat d’1 m.
Tots els cables han d’estar correctament etiquetats.
5.1.D.c.-Preses
Connectors fixes per a instal·lacions de comunicacions, col·locats encastats en caixes de
mecanismes.
El connector ha de quedar fixat sòlidament a la caixa de mecanismes. Tots els materials que
intervenen en la instal·lació han de ser compatibles entre sí. Les connexions han d’estar
fetes.
No s’han de transmetre esforços entre la connexió i el mecanisme. Per aquest motiu, el cable
ha d’anar folgat a dintre de la caixa de mecanismes.
Toleràncies d’instal·lació:
Posició: ± 20 mm Aplomat: ± 2%
Cal que les preses estiguin situades prop d’endolls elèctrics per tal de poder alimentar els
equips que es connecten a la xarxa telemàtica. Totes les preses han d’estar a menys de 70
cm d’una connexió a la xarxa elèctrica.
Totes les preses han d’estar correctament etiquetades.
059.3/10 25/01/2010
69
5.1.D.d.-Armaris
L’armari/Rack s’ubicarà en un espai d’accés exclusiu restringit, sense humitat, amb accés al
terra elèctric i de tal forma que es disposi d’una distància lliure mínima de 1,2m a cada cara
dels armaris que hagi de ser accedida.
Ha de quedar fixat sòlidament al suport pels punts previstos a la documentació tècnica del
fabricant i amb el sistema de fixació disposat pel fabricant. Tots els material que intervenen
en la instal·lació han de ser compatibles entre sí. S’ha de deixar l’espai suficient al voltant de
l’armari per tal de permetre les operacions de muntatge i manteniment. Les reixetes de
ventilació de l’armari no poden quedar obstruïdes. La porta ha d’obrir i tancar correctament.
Ha d’estar connectat a la xarxa d’alimentació elèctrica, la de protecció elèctrica, amb cables
de les seccions i tipus indicats a les instruccions tècniques del fabricant i que compleixin les
especificacions fixades a les seves partides d’obra.
L’armari ha de quedar connectat al conductor de terra. No s’han de transmetre esforços entre
els elements de la instal·lació elèctrica (tubs, canals, safates o cables) i els components de
l’equip. No ha de ser possible el contacte accidental amb les parts elèctricament actives un
cop acabades les feines de muntatge. La prova de funcionament ha d’estar feta.
Toleràncies d’instal·lació:
Posició: ±20 mm Aplomat: ±2%
5.1.D.e.-Canalitzacions
Les canalitzacions no podran estar ocupades més enllà del 40% de la seva capacitat, per al
doble motiu de permetre introduir nous cables i per evitar tensions i doblegaments del cable
estès.
En els canvis de direcció de la canalització el cable tindrà una curvatura mínima de 50mm. Si
no és possible garantir aquest límit al arribar a les preses, s’haurà de garantir la curvatura
mínima indicada per el fabricant.
Les esteses sobre safates o canaletes deixen lliures com a mínim 25mm per sobre dels
cables.
Per facilitar l’accés a les canaletes i safates es deixaran com a mínim 150mm per sobre. A les
canalitzacions tancades s’hi situaran registres d’accés com a mínim cada 12m.
059.3/10 25/01/2010
70
Les canalitzacions de cablejat estructurat hauran de ser independents de les escomeses i
xarxa de distribució elèctrica.
Es minimitzaran els creuaments entre la xarxa elèctrica i de xarxa telemàtica. En cas que la
xarxa elèctrica hagi de creuar el cablejat de xarxa telemàtica ho farà sempre amb un angle
de 90º i separats per un pont.
S’evitarà en la mesura del possible que el cablejat elèctric circuli per les safates en paral·lel
amb el cablejat de xarxa telemàtica. En cas que hi hagin de circular estaran separats per no
menys de 200mm en compliment de la normativa EN 50174.
Els cables en les safates haurien d’estar agrupats balderament en feixos de no més de 48
cables. Si el pes dels cables se suporta en horitzontal la safata s’ha de fixar en intervals de 1-
1,5m. En el pla vertical la fixació ha de ser aproximadament cada 500mm.
A les estances on el tram final del cablejat transcorre per canaleta fins arribar a la presa és
acceptable que no hi hagi separació amb els cables elèctrics, sempre que la distància total
així recorreguda en el tram final no superi els 15m.
5.1.D.f.-Canals plàstiques
El muntatge de les canals s’ha de fer mitjançant visos i tacs expansius per a fixar-la al
parament. Les unions dels trams rectes, derivacions, cantonades, etc., de les canals s’han de
fer amb peces d’unió fixades amb cargols o reblons. Les unions han d’estar a 1/5 de la
distància entre dos recolzaments. Els finals de canalització i els trams han d’estar coberts
amb tapetes de final de tram. Nombre de fixacions: >= 3/m
Toleràncies d’instal·lació:
Nivell o aplomat: <= 2 mm/m, <= 15 mm/total
5.1.D.g.-Safates plàstiques
El muntatge s’ha de fer amb peces de suport, amb un mínim de dues per safata, fixades al
parament amb tacs de PVC i visos. Les unions dels trams rectes, derivacions, cantonades,
etc., de les safates s’han de fer mitjançant una peça d’unió fixada amb cargols o reblons. Les
unions han d’estar a 1/5 de la distància entre dos recolzaments. Tots els elements auxiliars
(derivacions, corbes, regletes, etc.) han de ser de PVC. Els finals de canalització han d’estar
coberts sempre amb una tapa de final de tram.
059.3/10 25/01/2010
71
S’han considerat els tipus de col·locació següents:
Muntat superficialment: Els conductors han d’anar fixats al suports tele-rails, i aquests han
d’anar collats a la canalització amb separadors d’acer galvanitzat. Els tele-rails i els
separadors han de complir les especificacions fixades als seus plecs de condicions.
Distància entre les fixacions: <= 2,5 m
Toleràncies d’instal·lació:
Desploms: <= 1%, <= 30 mm
Fixada amb suports:
Toleràncies d’instal·lació: Nivell: <= 2 mm/m, <= 15 mm/total
5.1.D.h.-Equips electrònics per a la transmissió de dades
S’han d’instal·lar els equips següents:
• 1 encaminador (router) al rack R0
• 1 commutador (switch) al rack R0
• 6 Punts d´accés sense fil (AP) als llocs indicats al plànol
L’execució de la unitat d’obra inclou les operacions següents:
• Col·locació dins de l’armari (excepte els AP que van a la paret)
• Execució de les connexions elèctriques
• Configuració
• Prova de funcionament
Pel que fa als aparells que van a l’armari:
Ha de quedar fixat sòlidament a l’armari pels punts previstos a la documentació tècnica del
fabricant i amb el sistema de fixació disposat pel fabricant. No s’han de transmetre esforços
entre el plafó i l’armari. Tots els materials que intervenen en la instal·lació han de ser
compatibles entre si. Per aquest motiu, el muntatge i les connexions dels mecanismes han
d’estar fets amb els materials i accessoris subministrats pel fabricant, o expressament
aprovats per aquest. L’element ha de quedar connectat a la xarxa d’alimentació elèctrica i en
condicions de funcionament.
Els terminals de connexió de dades de la part frontal han de quedar accessibles. La porta de
l’armari ha de poder obrir i tancar correctament, fins i tot quan hi hagi connectats els cables
de la instal·lació de dades.
059.3/10 25/01/2010
72
Pel que fa als punts d’accés:
Ha de quedar fixat sòlidament a la paret pels punts previstos a la documentació tècnica del
fabricant i amb el sistema de fixació disposat pel fabricant. Tots els materials que intervenen
en la instal·lació han de ser compatibles entre si. Per aquest motiu, el muntatge i les
connexions dels mecanismes han d’estar fets amb els materials i accessoris subministrats pel
fabricant, o expressament aprovats per aquest. L’element ha de quedar connectat a la xarxa
d’alimentació elèctrica i en condicions de funcionament.
5.1.D.i.-Terra
Totes les superfícies conductives exposades han d’estar connectades a un punt de terra per
motius de seguretat en concordança amb les normatives europees EN 50174 i EN 50310.
En concret per al cablejat estructurat els armaris, els equips actius, els plafons de connectors
i les safates metàl·liques es consideren elements conductius i han d’estar connectades al
terra elèctric.
5.1.E.- Instal·lació i certificació
Quan a la instal·lació i l’empresa instal·ladora cal que es compleixin les següents condicions:
1. Tot el sistema de cablejat (cable, connectors, panells, repartidors i fuetons) serà
originari del mateix fabricant.
2. El sistema de cablejat s’instal·larà d’acord amb les instruccions del fabricant.
3. La planificació, control de qualitat, documentació i presa de terra es realitzarà segons
EN 50174 parts 1 i 2. Els cables externs s’instal·laran d’acord a EN 50174.
4. És precís realitzar amidaments de les característiques del 100% dels cables instal·lats.
5. El fabricant haurà de revisar y aprovar el 100% de les proves abans d’emetre una
garantia.
6. El cable ha de ser mesurat en els dos extrems, i els resultats guardats en una base de
dades electrònica compatible amb el programa de mesura de gestió de cable del
fabricant.
7. El cablejat tindrà una garantia de 15 anys proporcionada pel fabricant tant per
productes com per aplicacions, i serà instal·lat per un instal·lador acreditat i format pel
fabricant, formació que ha de ser acreditada i tenir una antiguitat de menys de dos
anys.
059.3/10 25/01/2010
73
8. El cablejat d’alimentació elèctrica i de dades es separaran segons l’estipulat per EN
50174 part 2, excepte en aquells casos en que sigui necessària una major separació
per ser d’aplicació normatives de seguretat elèctrica locals o nacionals.
9. L’instal·lador haurà d’emetre un certificat on hi consti el compliment de tots i cada un
dels punts anteriors, adjuntant un plànol indicant la situació i la numeració de cada
punt.
Òdena, 25 de Gener de 2010
Francesc Romà Frigolé
Enginyer de Telecomunicació Col·legiat Num. 12.461
059.3/10 25/01/2010
74
5.2.- INFRAESTRUCTURA RADIO / TELEVISIÓ
En aquest punt s’inclouen les especificacions del elements, materials, procediments o
condicions d’instal·lació i quadre de mesures per a cada tipus de servei.
5.2.A.- Radiodifusió sonora i televisió
5.2.A.a.-Característiques dels sistemes de captació
Les antenes i elements annexes (suports, ancoratges, vents, etc) hauran d’ésser de
materials resistents a la corrosió o tractats convenientment a aquests efectes.
Les astes o tubs que serveixin de suport a les antenes i elements annexes hauran d’estar
dissenyats de forma que s’impedeixi l’entrada d’aigua. En el cas que l’entrada d’aigua sigui
possible, caldrà assegurar-ne la correcta evacuació.
Les astes d’antena hauran d’estar connectades a la presa de terra de l’edifici a través del
camí més curt possible, amb cable de Cu de 25 mm2 de secció com a mínim. Es fixaran a
elements de fàbrica resistents i accessibles. Les antenes i elements del sistema captador de
senyals suportaran les següents velocitats de vent:
Per a sistemes situats a menys de 20 m. del terra: 130 Km/h.
Per a sistemes situats a més de 20m. del terra: 150 Km/h.
Totes les parts accessibles que s’hagin de manipular o aquelles amb les que el cos humà
pugui establir contacte hauran d’estar a potencial de terra o adequadament aïllades.
Amb la finalitat exclusiva de protegir l’equip captador i per tal d’evitar diferències de potencial
perilloses entre aquest i qualsevol altra estructura conductora, l’equip captador haurà de
permetre la connexió d’un conductor de coure de 25 mm2 de secció com a mínim amb el
sistema de protecció general de l’edifici.
Els cables de connexió dels sistemes de captació seran del tipus intempèrie.
A continuació es detallen les característiques dels elements passius:
059.3/10 25/01/2010
75
ANTENA UHF
Tipus Yagi
Canals 21-69
Guany (dB) 17
Relació D/A (dB) >28
Càrrega al vent (N) 800 N/ m2* 109,5
1100 N/ m2** 150,5
*Pressió de vent (N/m2) a 130 Km/h
**Pressió de vent (N/m2) a 150 Km/h
ANTENA FM
Banda FM
Guany (dB) 1
Relació D/A (dB) 0
059.3/10 25/01/2010
76
Càrrega al vent (N) 800 N/ m2* 27
1100 N/ m2** 37
*Pressió de vent (N/m2) a 130 Km/h
**Pressió de vent (N/m2) a 150 Km/h
ANTENA DAB
Banda 190-232
Guany (dB) 8
Relació D/A (dB) >15
Longitud (mm) 555
Càrrega al vent (N) 800 N/ m2* 36,5
1100 N/ m2** 50,2
*Pressió de vent (N/m2) a 130 Km/h
**Pressió de vent (N/m2) a 150 Km/h
ASTA
Longitud (mm) 1450
Diàmetre (mm) 35
Gruix (mm) 1.5
059.3/10 25/01/2010
77
Moment flector (Nm) 299.7
5.2.A.b.-Característiques dels elements actius
El conjunt d’elements actius són els que formen la capçalera, i són els encarregats de
processar els senyals de radiodifusió sonora, televisió i altres serveis de ràdio per ser
distribuïts posteriorment.
Les característiques tècniques que haurà de presentar la instal·lació a la sortida d’aquest
equipament són les següents:
L’equip d’amplificació de capçalera serà del tipus ample de banda programable. Tindrà les següents característiques:
AMPLIFICACIÓ CAPÇALERA
Tipus FM UHF 1/2/3 TDT RFU Radio Digital DAB
FI/SAT
Banda coberta (MHz) 87-108 470-862 47-68 174-230 950-2150 Guany (dB) Auto Auto Auto Auto 42-45 Nivell máx. de sortida (dBμV) 111 117 111 111 123 Figura de soroll (dB) 10 9 tip 10 10 9 Marge de regulació (dB) 0-25-OFF 0-20 0-25-PFF 0-25-PFF 0-12-OFF Refús entre can. (dB) 20 20 20 20 40 Consum (W) 30
Per a canals modulats en capçalera, el nivell autoritzat de la portadora de so en relació amb
la portadora de vídeo estarà comprès entre -8 i -20dB.
També, per als senyals que són distribuïts amb la seva modulació original, l’equip de
capçalera haurà de respectar la integritat dels serveis associats a cada canal (teletext, so
estereofònic, ...) i haurà de permetre la transmissió de serveis digitals.
5.2.A.c.-Característiques del elements passius
REPARTIDORS
Bandes mesclades MATV-FI
Pèrdues d’inserció (dB) <4 - <2
059.3/10 25/01/2010
78
Rebuig TV-FI > 20
Entrada d’FI amb pas de corrent DC
DERIVADORS
Nº de sortides 2 Pèrdues derivació V/U(dB) 15 Pèrdues derivació FI (dB) 15 Pèrdues inserció V/U (dB) 1,2 Pèrdues inserció FI (dB) 2
DISTRIBUÏDORS
Nº sortides 2 3
Pèrdues d’inserció (dB UHF 4,5 7
FI 5,5 9
Rebuig entre sortides (dB) >24 >24
Pas DC entrada - sortida Si
CABLE
Atenuació 50 MHz (dB/m) 0,04
Atenuació 200 MHz (dB/m) 0,08
Atenuació 600 MHz (dB/m) 0,142
Atenuació 800 MHz (dB/m) 0,154
Atenuació 1000 MHz (dB/m) 0,187
Atenuació 1500 MHz (dB/m) 0,234
Atenuació 1750 MHz (dB/m) 0,243
Atenuació 2150 MHz (dB/m) 0,278
Conductor central de coure i dielèctric de polietilè cel·lular físic.
059.3/10 25/01/2010
79
Pantalla cinta metal·litzada i trena de coure o alumini
Coberta no propagadora de la flama per instal·lacions interiors i de polietilè per instal·lacions exteriors.
Impedància característica: 75 ± 3 Ω.
Es consideren conformes els cables homologats segons les normes UNE-EN 501117-5 per instal·lacions interiors i UNE-EN-50117-6 per instal·lacions exteriors.
PRESES TV – SAT (BAT)
Tipus RTVSAT Banda coberta 5-2150 MHz Pèrdues de derivació V/U 1 dB
Pèrdues de derivació FI 1.5 dB Impedància 75 Ω
5.2.B.- Telefonia disponible al públic
5.2.B.a.-Característiques dels cables:
Els cables estaran formats per parells trenats amb conductors de coure electrolític pur de
calibre no inferior a 0,5 mm. De diàmetre, aïllat amb una capa contínua de plàstic
colorada segons codi de colors.
Pel cable de dos parells utilitzat, la coberta estarà formada per una capa contínua de
plàstic de característiques ignífugues. El diàmetre exterior d’aquest cable serà de 5 mm.
Com a màxim.
La resistència òhmica dels conductors a la temperatura de 20ºC no serà més gran de 98
Ω/Km.
La rigidesa dielèctrica entre conductors no serà inferior a 500 Vcc ni a 350 Vef ca.
La rigidesa dielèctrica entre el nucli i la pantalla no serà inferior a 1500 Vcc ni a 1000 Vef ca.
La resistència d’aïllament no serà inferior a 1000 M Ω/Km.
La capacitat mútua de qualsevol parell no passarà de 100 nF/Km en cables de PVC, i de
58 nF/Km en cables de polietilè.
059.3/10 25/01/2010
80
5.2.B.b.-Característica de les regletes.
Estan constituïdes per un bloc de material aïllant proveït d’un nombre variable de
terminals. Cadascun d’aquests terminals té un costat preparat per connectar els
conductors de cable, i l’altre costat està disposat de tal forma que permet el connexionat
dels cables d’escomesa interior o dels ponts.
El sistema de connexió serà per desplaçament d’aïllant, realitzant-se la connexió
mitjançant una eina especial en el punt d’interconnexió.
Les pastilles de connexió utilitzades al punt d’interconnexió són de 10 parells de capacitat.
Les pastilles de connexió de distribució usades al punt de distribució seran de 5 parells de
capacitat, s’empraran de tall i prova, pel que estaran dotades de la possibilitat de
mesurar cap a ambdós costats sense necessitat d’aixecar les connexions.
La resistència a la corrosió dels elements metàl·lics haurà de ser tal que suporti les proves
estipulades a la norma UNE 20501-83 (II-11), equivalent a la norma CEI 68-2-11.
La resistència d’aïllament entre contactes en condicions normals (23ºC i 50% d’humitat
relativa), haurà de ser superior a 106 MΩ.
La resistència de contacte amb el punt de connexió dels cables/fils haurà de ser inferior a
10 mΩ.
La rigidesa dielèctrica haurà de ser tal que suporti una tensió, entre contactes, de 1000
Vef ca ± 10% i 1500 Vcc ± 10%.
5.2.C.- Infraestructura
5.2.C.a.-Característiques de les arquetes
Les arquetes hauran de suportar les sobrecàrregues normalitzades en cada cas i
l’empenta del terreny. La tapa tindrà una resistència mínima de 5kN. Hauran de tenir un
grau de protecció IP55. Les arquetes d’entrada, a més a més, disposaran de tanca de
seguretat i de dos punts per a l’estesa de cables en parets oposades a les entrades de
conductes situats a 150 mm. Del fons, que suportin una tracció de 5kN.
5.2.C.b.-Característiques de la canalització externa.
- Els tubs utilitzats seran de paret interior llisa.
059.3/10 25/01/2010
81
- A tots els tubs no utilitzats en qualsevol de les canalitzacions s’hi deixarà instal·lat
un fil guia (filferro d’acer galvanitzat, corda plàstica,...), sobresortint 20 cm. Pels
extrems de cada tub.
- Seran no propagadors de la flama i els metàl·lics seran resistents a la corrosió.
5.2.C.c.-Condicionants a tenir en compte en el registre de telecomunicacions.
- El registre de telecomunicacions disposarà de ventilació natural directa, ventilació
natural forçada a través de conducte vertical i aspirador estàtic o de ventilació
mecànica que permeti una renovació total de l’aire del local un mínim de 2
vegades cada hora.
- El sistema general de terra de l’edifici haurà de tenir un valor de resistència
elèctrica no superior a 10 Ω respecte de la terra llunyana.
- El sistema de terra del registre constarà essencialment d’un anell interior i tancat
de coure. Aquest serà fàcilment accessible i de dimensions adequades, i estarà
connectat directament al sistema de terra general de l’edifici en un o més punts. A
aquest terminal s’hi connectarà el conductor de protecció o d’equipotencialitat i els
altres components o equips que han d’estar connectats a terra regularment.
- L’anell i el cable de connexió al terminal general de terra de l’edifici estaran
formats per conductors flexibles de coure de 25 mm2 de secció com a mínim. Els
suports, bastidors, safates, ... metàl·lics dels recintes estaran units al terra local.
Si a l’edifici hi ha més d’una presa de terra de protecció, aquestes hauran d’estar
elèctricament unides.
- Grau d’estanqueïtat mínima IP33 segons norma UNE-EN 60529 i resistència a
l’impacte dels elements de tancament de IK10 segons norma UNE EN 50102.
5.2.C.d.-Característiques dels registres de planta i registres d’accés d’usuari.
- Tots els armaris utilitzats tindran un grau de protecció IP33 segons norma UNE EN
60529 com a mínim.
- Tots els armaris utilitzats tindran un grau IK7 segons norma UNE EN 50102 com a
mínim.
CARACTERÍSTIQUES DELS REGISTRES DE PRESA D’USUARI.
059.3/10 25/01/2010
82
- Hi haurà d’haver una presa de corrent elèctric a una distància de 0,6 m de cada
punt de presa de radiodifusió i televisió.
5.2.C.e.-Característiques dels tubs.
- Els tubs utilitzats per les canalitzacions externa, d’enllaç i principal seran de paret
interior llisa.
- A tots els tubs no utilitzats en qualsevol de les instal·lacions s’hi deixarà instal·lat
un fil guia (filferro d’acer galvanitzat, corda plàstica, ...), sobresortint 20 cm. Pels
extrems de cada tub.
- Seran no propagadors de la flama i els metàl·lics seran resistents a la corrosió.
5.2.C.f.-Requisits de seguretat entre instal·lacions.
- Es procurarà la màxima independència entre les instal·lacions de
telecomunicacions i la resta de serveis.
- La separació entre una canalització de telecomunicació i els serveis serà, com a
mínim, de 100 mm. Per a traçats paral·lels i de 30 mm per a encreuaments.
5.2.D.- Quadre de mesures
5.2.D.a.-Radiodifusió sonora i televisió terrestres.
Cal realitzar la comprovació de totes les magnituds descrites a l’apartat “3.2.A.g. Càlcul
de paràmetres bàsics de la instal·lació”:
PARÀMETRE MESURA Nivell de senyal AM-TV ≥ 57 dBμV
Nivell de senyal
COFDM-TV ≥ 45 dBμV
Nivell de senyal
64QAM-TV ≥ 45 dBμV Nivell de senyal FM-TV ≥ 47 dBμV
Nivell de senyal QPSK-
TV ≥ 45 dBμV Nivell de senyal FM-TV ≥ 40 dBμV
Resposta 47-862 mHz: ±3
dB a 47-862 mHz: ±3
dB a
amplitud/freqüència tota la banda i
±0,5 dB tota la banda i
±0,5 dB
en canal en un ample de
banda en un ample de
banda d'1 MHz d'1 MHz Resposta
059.3/10 25/01/2010
83
amplitud/freqüència 47-862 MHz: 12
dB 950-2150 MHz:
25 dB en banda de la xarxa
Relació portadora/soroll
aleatori C/N AM-TV ≥ 43 dB C/N COFDM-TV ≥ 23 dB C/N 64QAM-TV ≥28 dB C/N FM-TV ≥ 15 dB C/N QPSK-TV ≥ 11 dB C/N FM ràdio ≥ 38 dB Desacoblament entre 47-300 MHz: 300-862 MHz: 47-300 MHz: preses d’usuaris ≥ 38 ≥ 30 ≥ 38 Intermodulació simple AM-TV ≥ 54 dB 64QAM-TV ≥ 35 dB FM-TV ≥ 27 dB QPSK-TV ≥ 18 dB Intermodulació múltipla AM-TV ≥ 54 dB 64QAM-TV ≥ 35 dB FM-TV ≥ 27 dB QPSK-TV ≥ 18 dB
5.2.E.- Reglament de Prevenció de Riscs Laborals
- Directiva 92/67 CEE del 24 de juliol (DO: 26/8/92): disposicions mínimes de
seguretat i salut que cal aplicar a les obres de construcció.
- Real Decret 1627/71997 de 24 d’octubre (BOE 25.10.97): Disposicions mínimes de
seguretat i salut que s’han d’aplicar a les obres de construcció.
- Llei 31/1995 de 8 de novembre (BOE 10.11.95): Llei de prevenció de riscs laborals i
disposicions per al seu desenvolupament.
- Real Decret 39/1997 de 17 de gener (BOE 31.01.95) reglament dels serveis de
prevenció.
- Real Decret 486/1997 de 14 d’abril (BOE 23.04.97) Disposicions mínimes de
seguretat i salut en els llocs de treball.
- Real Decret 487/1997 de 14 d’abril (BOE 23.04.97) Disposicions mínimes de
seguretat i salut relatives a la manipulació manual de càrregues que comporti riscs, en
particular esquena i lumbars, per als treballadors.
059.3/10 25/01/2010
84
- Real Decret 685/1997 de 12 de maig (BOE 24.05.97). Protecció dels treballadors
contra riscs relacionats amb l’exposició a agents cancerígens durant el treball.
- Real Decreto 773/1997 de 30 de maig (BOE 23.04.97). Disposicions mínimes de
seguretat i salut relatives a la utilització pels treballadors d’equips de protecció
individual.
- O.M de 20 de Maig del 1952 (B.O.E. 15/06/52): reglament de seguretat i higiene en
el treball a la industria i la construcció.
Modificació: O. Del 10 de desembre de 1953 (B.O.E. 22/12/53).
O. del 23 setembre de 1966 (B.O.E. 01/10/68).
O. del 20 de gener de 1956.
5.2.F.- Normativa sobre protecció contra camps electromagnètics Normes:
- UNE - EN - 50083-1
- UNE - EN - 50083-2
- UNE - EN - 50083-8
5.2.G.- Altres.
- Reglament Electrotècnic per a baixa tensió ( R.D. 842/2002 de 2 d’agost –
B.O.E 224 del 18/09/2002).
- Reglament de línies aèries d’alta tensió. (O.M. 28/11/68).
- Reglament d’aparells a pressió (R.D. 1244/97).
- Real Decret 1316/89 i Llei 16/2002, sobre soroll i contaminació acústica.
Òdena, 25 de Gener de 2010
Marc Guitart i Garcia Enginyer Tècnic de Telecomunicació
(Especialitat en Imatge i So) Col·legiat Num. 10.460
059.3/10 25/01/2010
85
6.- ANNEX I: ATENUACIONS TOTALS EN PRESES D’USUARI
059.3/10 25/01/2010
86
UHF
PLANTA 1 ESPAI CUINA PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 3 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 0,0 15,0 0,0 7,0 14,0 0,56 22,56200 1,12 23,12600 1,99 23,99800 2,16 24,16
PLANTA 1 ESPAI TALLER 4 PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 3 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 0,0 15,0 0,0 7,0 16,0 0,64 22,64200 1,28 23,28
600 2,27 24,27800 2,46 24,46
PLANTA 1 ESPAI TALLER 2+3 PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 3 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 0,0 15,0 0,0 7,0 17,0 0,68 22,68200 1,36 23,36600 2,41 24,41800 2,62 24,62
PLANTA PB ESPAI GIMNÂS PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor X Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 0,0 15,0 0,0 0,0 26,0 1,04 16,04200 2,08 17,08600 3,69 18,69800 4,00 19,00
059.3/10 25/01/2010
87
PLANTA PB ESPAI SALA 4 PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor X Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 0,0 15,0 0,0 0,0 31,0 1,24 16,24200 2,48 17,48600 4,40 19,40800 4,77 19,77
PLANTA PB
ESPAI SALA POLIVALENT
PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 2 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 1,2 15,00 0,00 4,50 59,0 2,36 23,06200 4,72 25,42600 8,38 29,08800 9,09 29,79
PLANTA PB
ESPAI SALA REUNIONS
PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 2 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
50 1,20 15,00 0,00 4,50 59,0 2,36 23,06200 4,72 25,42600 8,38 29,08800 9,09 29,79
059.3/10 25/01/2010
88
FI PLANTA 1 ESPAI CUINA PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 3 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 0,0 15,0 0,0 9,0 14,0 2,62 26,621500 3,28 27,281750 3,57 27,572150 4,02 28,02
PLANTA 1 ESPAI TALLER 4 PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 3 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 0,0 15,0 0,0 9,0 16,0 2,99 26,991500 3,74 27,74
1750 4,08 28,082150 4,59 28,59
PLANTA 1 ESPAI TALLER 2+3 PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 3 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 0,0 15,0 0,0 9,0 17,0 3,18 27,181500 3,98 27,981750 4,34 28,342150 4,88 28,88
PLANTA PB ESPAI GIMNÀS PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor X Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 0,0 15,0 0,0 0,0 26,0 4,86 19,861500 6,08 21,081750 6,63 21,632150 7,46 22,46
PLANTA PB ESPAI SALA 4 PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor X Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 0,0 15,0 0,0 0,0 31,0 5,80 20,801500 7,25 22,251750 7,91 22,912150 8,90 23,90
059.3/10 25/01/2010
89
PLANTA PB ESPAI SALA POLIVALENT PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 2 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 2,00 15,00 0,00 5,50 59,0 11,03 33,531500 13,81 36,311750 15,05 37,552150 16,93 39,43
PLANTA PB
ESPAI SALA REUNIONS
PRESA Única FREQ. (MHz)
Derivador pas (dB)
Derivació (dB)
PAU (db)
Repartidor 2 Sortides (dB)
Cable (m)
Atenuació Cable (dB)
Atenuació Total (dB)
1000 2,00 15,00 0,00 5,50 59,0 11,03 33,531500 13,81 36,311750 15,05 37,552150 16,93 39,43
Òdena, 25 de Gener de 2010
Marc Guitart i Garcia Enginyer Tècnic de Telecomunicació
(Especialitat en Imatge i So) Col·legiat Num. 10.460
059.3/10 25/01/2010
90
7.- ANNEX II: ESTUDI BÀSIC
DE SEGURETAT I SALUT
059.3/10 25/01/2010
91
7.1.- MEMÒRIA DESCRIPTIVA
7.1.A.- Objecte Aquest estudi bàsic de seguretat i salut del projecte de Telecomunicacions complementa
l’estudi de seguretat i salut del projecte arquitectònic, essent només objecte d’aquest estudi
bàsic l’execució de les instal·lacions compreses en el present projecte de Telecomunicacions.
Aquests estudis seran desenvolupats i complementats pel pla de seguretat i salut al treball
que serà redactat pel contractista segons estableix l’article 7 del mateix Real Decret.
L’edifici sobre el qual es desenvoluparan els treballs és un edifici destinat a l’ús públic.
7.1.B.- Descripció dels treballs. Fases de l’obra
7.1.B.a.-Canalitzacions Aquesta fase en l’execució del projecte de Telecomunicacions comprendrà la realització de les
canalitzacions dels tubs o cables de la instal·lació, així com l’arqueta d’entrada i el registre
de telecomunicacions. Treballs típics seran tasques de l’obra com la realització de regates als
envans o parets i el posterior emblanquinat. Els treballs especialment crítics són la
canalització superior d’entrada i la col·locació dels equips de captació (antenes) i els seus
suports, per la fatalitat de les conseqüències d’una caiguda des d’aquell punt.
Les rases destinades a albergar la canalització d’entrada s’estima tindran una profunditat
màxima de 90 cm, pel que no es preveu sigui necessari cap tipus d’apuntalament.
7.1.B.b.-Instal·lacions de RTV, TB+RDSI, TLCA i SAFI Aquesta fase en l’execució del projecte de Telecomunicacions comprendrà la realització
d’instal·lació de ràdio i televisió via terrena o satèl·lit, instal·lació de telefonia bàsica,
instal·lació de televisió per cable i servei d’accés físic inalàmbric. Treballs típics seran la
col·locació de presa de corrent, pas de cables per canalitzacions o connexions d’equips
electrònics. En aquesta fase de l’obra els riscs principals seran el de descàrrega elèctrica i els
derivats de treballar en un edifici en construcció.
7.1.C.- Treballs amb riscs especials Instal·lació d’antenes i pals. Probablement el treball més perillós per les possibles
conseqüències d’una caiguda des de la coberta de l’edifici.
Normes a seguir:
059.3/10 25/01/2010
92
No s’executarà el treball fins que la coberta estigui acabada i quedi garantida l’estabilitat
estructurat d’aquest element.
En el cas d’haver estat retirades les baranes, tots els treballadors que accedeixin a la coberta
per a aquest treball romandran lligats per mitjà d’un arnès de seguretat a la línia de vida
disposada a tal efecte. Aquesta mesura és obligatòria per a tots els treballadors.
S’instal·larà una línia de vida des de l’escala d’accés a la coberta fins el punt d’ubicació
d’antenes. S’executarà amb cable d’acer a la coberta d’almenys 8 mm de diàmetre, amb
ancoratges embotits a la coberta i distanciats un màxim de 3 metres entre si. El conjunt
proporcionarà una resistència d’almenys 150 Kg/m. Aquest element quedarà fix en la
instal·lació per poder ser usat en treballs posteriors.
Es tindrà especial cura al traslladar els pals i els elements accessoris, de què no caigui cap
peça coberta a baix.
En les fases d’instal·lació de tots els equips i sistemes, especialment als treballs sobre la
coberta, l’instal·lador sempre haurà de comptar amb aigua potable per evitar
deshidratacions.
Per a la fase d’instal·lació de les preses d’usuari es dotarà a cada instal·lador d’una cadira
plegable, que eviti posicions de treball perllongats amb els genolls doblegats, o que els
instal·ladors hagin d’estar asseguts al terra.
7.1.D.- Riscs més freqüents.
7.1.D.a.-Riscs evitables Contacte amb instal·lacions elèctriques:
Abans de l’inici de cada treball es comprovarà que no afecti a instal·lacions elèctriques
existents, i si aquestes existissin es procediria a la seva desconnexió abans de l’inici dels
treballs, col·locant un cartell que indiqui: “No connectar, homes treballant en la xarxa”.
7.1.D.b.-Riscs no evitables
Caigudes d’alçada Caigudes al mateix nivell
Cops i talls amb les eines
Punxades i atrapaments
Petites projeccions
059.3/10 25/01/2010
93
Dermatitis amb contacte amb el ciment Descàrregues elèctriques
Sobreesforços
Projecció de partícules als ulls
7.1.E.- Normes bàsiques de seguretat
Es comprovarà l’estabilitat del lloc de treball, així com l’existència de les proteccions que fossin necessàries, per evitar caigudes a distints nivells (baranes, xarxes...)
Tots els treballadors seran informats dels riscs existents a l’obra i les mesures
preventives necessàries. Es prohibirà el maneig d’aparells elèctrics o manipulació d’instal·lacions elèctriques, a
persones no designades per a això, o que no tinguin la instrucció adequada. Es tindrà cura de l’ordre i la neteja durant l’execució dels treballs.
Les eines de mà es portaran enganxades amb mosquetó per evitar la seva caiguda a
un altre nivell. Les eines manuals estaran en bones condicions.
Es disposarà d’una il·luminació adequada. Si és de tipus portàtil, serà estanca a l’aigua
i estarà convenientment aïllada.
Es comprovarà que les connexions dels equips a la xarxa elèctrica tinguin presa de terra i estiguin en bon estat. Només s’utilitzarà material elèctric en perfecte estat de conservació, renovant aquest material quant s’apreciï deterioració en les seves parts aïllants.
La instal·lació elèctrica es considerarà baixa tensió mentre no es comprovi el contrari
amb els aparells adequats. No es trepitjaran els conductors ni es deixaran objectes sobre d’ells.
Es prohibirà l’accés a tota persona aliena a l’obra.
S’ha de vetllar per la utilització dels equips de protecció posats a disposició del
personal.
7.1.F.- Equips de protecció individual (E.P.I.).
Roba de treball: S’utilitzarà en totes les fases de l’obra. Guants aïllants: Per a aquells treballs en els quals s’hagi de manipular material
elèctric. Guants de goma o neoprè: Per a aquelles fases en les quals s’utilitza formigó o
ciment. Guants de cuir: Per als treballs de descàrrega i moviments de materials.
059.3/10 25/01/2010
94
Botes de seguretat: S’utilitzarà en totes les fases de l’obra.
Casc de Polietilè: S’utilitzarà en totes les fases de l’obra.
Ulleres de seguretat: Si existeix risc de projeccions o un nivell elevat de pols (Ex.
Execució de fregaments). Cascs antisoroll: Quan el nivell de soroll sobrepassi els 80 dB.
Arnès de seguretat: S’utilitzarà degudament collat per a aquells treballs amb risc de
caiguda a distint nivell, en els quals no existeixi protecció col·lectiva (Ex. Col·locació d’antenes al terrat).
7.1.G.- Proteccions col·lectives Donat que la instal·lació objecte d’aquest projecte es desenvoluparà sobre un edifici en
construcció, aquest haurà de disposar de totes les mesures de protecció que li siguin
d’aplicació, i que es trobin recollides a l’estudi de seguretat i salut adjunt al projecte
arquitectònic, no essent objecte d’aquest estudi bàsic, les mesures generals de protecció amb
les quals hagi de comptar l’edifici.
Algunes mesures són generals, com les mesures contra el risc elèctric o d’incendis, i unes
altres seran d’ús concret als talls que les utilitzin: línia de vida, escales, etc. La senyalització
no és una protecció col·lectiva, però és necessària sempre que els riscs no puguin evitar-se o
limitar-se suficientment a través de mitjans tècnics de protecció col·lectiva o de mesures,
mètodes o procediments d’organització del treball.
7.1.G.a.-Senyalització Es senyalitzaran amb especial atenció les conduccions elèctriques en servei i aquells punts
que estiguin sota tensió.
En cas de faltar proteccions col·lectives per ser zona de nova construcció, es senyalitzarà
expressament, prohibint l’accés a aquelles àrees.
Es delimitaran amb cinta d’abalisament les vores d’excavacions i rases. Així com les
conduccions que per estar a baixa alçada suposin un obstacle.
Per a la senyalització s’utilitzaran els següents colors:
059.3/10 25/01/2010
95
Color Significat Indicacions
Vermell Prohibició Perill-alarma Prevenció incendis
Comportaments perillosos Aturada Identificació
Groc o Taronja Advertència Precaució Blau Obligació Ús d’E.P.I. Verd Llocs/ situacions segures Portes i sortides
Situació de normalitat En qualsevol cas advertiran de la presència de riscs no evidents i informaran sobre l’estat de
les instal·lacions, s’emprarà amb el criteri disposat a l’article 4 del Real Decret 485/1997, de
14 d’abril, sobre disposicions mínimes en matèria de senyalització de seguretat i salut al
treball.
7.1.G.b.-Instal·lació Elèctrica La instal·lació elèctrica complirà allò establert als Reglaments d’Alta i Baixa Tensió i
resolucions complementàries del Ministeri d’Indústria. Els quadres de distribució estaran
formats per armaris metàl·lics normalitzats, amb placa de muntatge al fons, fàcilment
accessible des de l’exterior. Per això disposarà de porta amb un pany amb clau i amb
possibilitat de posar un cadenat. Disposaran de seccionador de tall automàtic, presa de terra,
i interruptor diferencial.
L’interruptor diferencial serà de mitja sensibilitat, és a dir, de 300 ma., en cas de que totes
les màquines i aparells estiguin posats al terra, i els valors de la resistència d’aquestes no
sobrepassi els 80 Ohms. Per a la protecció contra sobrecàrregues i curtcircuits disposaran de
fusibles o interruptors automàtics del tipus magnetotèrmic. D’aquest quadre de distribució
que considerem general s’efectuaran les preses de corrent per als circuits secundaris, que
igualment disposaran d’armaris amb entrada de corrent estanc, amb arribada de força
sempre sobre base d’endoll femella. Aquests quadres disposaran d’aristol general de presa de
terra, d’un interruptor de tall omnipolar, tipus normal, curtcircuits calibrats per a cada una de
les preses, tres com a màxim, i diferencial d’alta sensibilitat (30 mA). En cas d’utilització de
màquines portàtils en zones de gran humitat, es contarà amb transformadors d’intensitat a
24V, per treballar amb aquesta tensió de seguretat.
7.1.G.c.-Mesures de seguretat en instal·lacions elèctriques. Com a normes generals d’actuació en relació amb aquestes instal·lacions han d’observar-se
les següents:
Els borns, tant de quadres com de màquines, estaran protegits amb material aïllant.
059.3/10 25/01/2010
96
Els cables d’alimentació a màquines i eines tindran cobertes protectores, seran del tipus antihumitat i no hauran d’estar en contacte o sobre el terra en zones de trànsit.
Està totalment prohibit la utilització de les puntes nues dels cables, com a clavilles
d’endoll mascle. Als magatzems de l’obra es disposarà de recanvis anàlegs, i en nombre suficient, per
poder substituir en qualsevol moment l’element deteriorat, sense perjudici per a la instal·lació ni per a les persones.
Totes les línies elèctriques queden sense tensió al donar per finalitzat el treball, per
mitjà de tall del seleccionador general. La revisió periòdica de totes les instal·lacions és condició imprescindible. Es realitzarà
amb la major escrupolositat per personal especialitat. Afectarà tant a l’aïllament de cada element o màquina, així com a l’estat de mecanismes, proteccions, conductors, cables, de la mateixa manera que a les seves connexions o entroncaments.
Els portalàmpades seran de material aïllant, de forma que no produeixin contacte amb
altres elements o curtcircuits. Tota reparació es realitzarà previ tall de corrent, i sempre per personal qualificat.
Els quadres elèctrics romandran tancats, quedant les claus en poder d’una persona
responsable. Es senyalitzarà a través de cartells el perill de risc elèctric, així com el moment en què
s’estiguin realitzant treballs de conservació.
7.1.G.d.-Protecció contra incendis Per a la prevenció d’aquest risc es disposarà en l’obra d’extintors portàtils de pols seca
polivalent, per a focs tipus A i B, i de diòxid de carboni per a focs d’origen elèctric.
7.1.G.e.-Mesures de seguretat contra el foc
S’instruirà els treballadors en el maneig d’extintors i en la prevenció d’incendis. Es tallarà el corrent des del quadre general, evitant curtcircuits, una vegada
finalitzada la jornada laboral. Es prohibirà fumar en les zones de treball on existeixi un perill evident d’incendi, a
causa dels materials que s’emprin. Es donarà senyal d’alarma davant qualsevol conat d’incendi, procedint a l’evacuació de
tot el personal fins que la situació estigui controlada. S’avisarà el servei de bombers davant qualsevol incidència.
Les persones alienes a l’empresa tindran prohibida l’entrada a l’obra.
059.3/10 25/01/2010
97
7.1.G.f.-Cables de subjecció de l’arnés de seguretat i els seus ancoratges
Tindran una resistència superior a 150 kg/m per suportar els esforços als quals aquests
puguin ser sotmesos, d’acord amb la seva funció protectora. Haurà de comprovar-se la seva
resistència abans de cada ús.
7.1.G.g.-Escales de mà El seu ús s’evitarà en la mesura del possible. Seran metàl·liques, excepte en treballs elèctrics
que hauran de ser de material aïllant, i disposaran de safates antilliscants. No s’utilitzaran
escales de fusta amb esglaons clavats, aquests hauran de ser engalzat.
7.2.- Plànols Per a aquesta instal·lació no es considera necessària la inclusió de cap plànol.
7.3.- Plec de condicions particular S’aplicaran especialment les disposicions mínimes de seguretat i salut recollides a l’annex IV
del Real Decret 1.627/97 de 24 d’octubre, i els principis d’acció preventiva que es recullen a
l’article 15 de la Llei de Prevenció de Riscs Laborals. A més s’hauran de tenir en compte
totes les disposicions següents:
Estatut dels treballadors
Conveni General del Sector de Construcció
Conveni Col·lectiu Provincial de la Construcció
Reglament Electrotècnic de Baixa Tensió. (O.M. 20-09-73 publicada al B.O.E. 09-10-
73) Real Decret 2.291/1985 de 8 de novembre, pel qual s’aprova el Reglament d’Aparells
d’Elevació i Manutenció dels mateixos. Ordre de 28 de juny de 1988, per la qual s’aprova la Instrucció Tècnica
Complementària MIE- AEM2, del Reglament d’Aparells d’Elevació i Manutenció referent a grues torre desmuntables per a obra.
Ordre de 16 d’abril de 1990, per la qual es modifica la Instrucció Tècnica
Complementària MIE- AEM2, del Reglament d’Aparells d’Elevació i Manutenció referent a grues torre desmuntables per a obra.
Llei 31/95 de 8 de novembre, sobre Prevenció de Riscs Laborals.
059.3/10 25/01/2010
98
Real Decret 1.316/1989, sobre el soroll. Real Decret 2.177/1996 de 4 d’octubre, pel qual s’aprova la Norma Bàsica de
l’Edificació. “NBE-CPI/96”: Condicions de protecció contra incendis als edificis.
Real Decret 485/1997 de 14 d’abril, sobre disposicions mínimes en matèria de
senyalització de Seguretat i Salut al treball. Real Decret 486/1997 de 14 d’abril, pel qual s’estableixen les disposicions mínimes de
seguretat i salut als llocs de treball. Real Decret 487/1997 de 14 d’abril, sobre disposicions mínimes de Seguretat i Salut
relatives a la manipulació manual de càrregues que comportin riscs, en particular del dors i lumbars, per als treballadors.
Real Decret 773/1997 de 30 de maig, sobre disposicions mínimes de Seguretat i Salut
relatives a la utilització pels treballadors d’equips de protecció individual. Real Decret 1.215/1997 de 18 de juliol, pel qual s’estableixen les mesures mínimes de
seguretat i salut per a la utilització d’equips de treball. Real Decret 1.389/1997 de 5 de setembre, pel qual s’aproven les disposicions mínimes
destinades a protegir la Seguretat i la Salut dels treballadors en les activitats mineres. Real Decret 1.627/1997 de 24 d’octubre, pel qual s’estableixen disposicions mínimes
de seguretat i salut a les obres de construcció. Real Decret 216/1999 de 5 de febrer, sobre disposicions mínimes de seguretat i salut
al treball en l’àmbit de les empreses de treball temporal. Llei 38/1999 de 5 de novembre, d’Ordenació de l’Edificació.
059.3/10 25/01/2010
99
7.4.- Pressupost El pressupost s’elabora amb la previsió d’un nombre màxim de dos o quatre treballadors a
l’obra. Donada la breu duració dels treballs no es preveu la restitució de material per
deterioració o envelliment, encara que si això es produís s’haurà de renovar el material
afectat.
Descripció Uts. Preu Unitari Preu
Total Botes de seguretat 2 88,00 176,00 Guants aïllants 2 37,00 74,00 Guants de neoprè 2 37,00 74,00 Guants de cuir 2 42,00 84,00 Casc de polietilè 2 25,00 50,00 Cartells informatius de risc 5 18,00 90,00 Extintor 6 Kg. Ef. 21A/113B 1 48,00 48,00 Ulleres protectores 2 19,00 38,00 Arnès de seguretat 2 88,00 176,00 Lloguer de bastida de seguretat 0 620,00 0,00 Línia de vida 8 mm instal·lada(ml.) 10 18,00 180,00
El total del pressupost d’execució d’aquest estudi bàsic de seguretat i salut puja a la quantitat de 990 EUROS.
Òdena, 25 de Gener de 2010
Francesc Romà Frigolé Marc Guitart i Garcia Enginyer de Telecomunicació Enginyer Tècnic de Telecomunicació
(Especialitat en Imatge i So)
Col·legiat Num. 12.461 Col·legiat Num. 10.460
059.3/10 25/01/2010
100
8.- PRESSUPOST
CAPÍTOL 1 CABLEJAT ESTRUCTURALVEU I DADES
Codi Nom Preu UnitatPreses
1 Presa de veu/dades d’execució encastada composta per un mecanisme simple tipus RJ45 categoria 6, caixa d’encast i marc enbellidor, inclòs accessoris i connectors. Completament instal·lat i connectat. 90,00 € u
Certificació
2 Certificació, de tots els punts de veu i dades i preses de telefonia, segons normativa EN50173-1:2002, Categoria 6/Classe E. Lliurant els documents d’homologació i calibrat de l'equipament, i les certificacions, en format electrònic, a la direcció facultativa. 9,00 € u
CANALITZACIONS
Safata PVC 200x603 Safata de PVC 200x60 mm amb part proporcional d'unions, accessoris i suports, completament instal·lada 9,90 € ml
Canaleta de PVC 30x60
4 Canaleta de PVC 30x60mm amb tapa muntada superficialment., amb part proporcional de separadors, accessoris i fixacions, completament instal·lada 4,50 € ml
Tub PVC Ø505 Tub de PVC de 50mm de diàmetre per a cablejat estructurat, inclòs tot el material de fixació i caixes de derivació, completament instal·lat 12,70 € ml
Tub PVC Ø20 corrugat
6 Tub de PVC corrugat de 20mm de diàmetre per al cablejat estructurat, inclòs tot el material de fixació i caixes de derivació, completament instal·lat. 1,53 € ml
Cable UTP Cat.6
7 Cable UTP Categoria 6/Classe E 4 parells 100 ohm d’un material lliure d’halògens, amb baixa emissió de fum (LSZH) i amb piroretardants. Completament instal·lat. 1,58 € ml
EQUIPAMENT DE XARXA
Commutador
8 Commutador (switch) Cisco Catalyst 2960, model 2960G-48TC-L, 48 ports ethernet 10/100/1000 4 dels quals son duals SF GE, muntat en rack, inclòs accessoris, configuració i comprovació de funcionament 2.880,00 € u
Encaminador
9 Encaminador (router) Cisco 1900, model 1941/K9, amb dos ports Gigabit Ethernet, 2 ranures d'ampliació EHWIC, 1 ranura d'ampliació ISM, 256MB CF, 512 DRAM. muntat en rack, inclòs accessoris, configuració i comprovació de funcionament 1.170,00 € u
Punt d'Accés sense fils (WiFi)
10 Punt d’accés sense fil Cisco Aironet 1140, model AIR-LAP1142N-E-K9-Dual-band, per a controlador extern, 802.11a/g/n, muntat a la paret, inclòs accessoris, configuració i comprovació de funcionament 1.080,00 € u
Controlador de xarxa
11 Controlador de xarxa sense fil Cisco 2006 per a 6 punts d’accés i 8 ports Ethernet 10/100, compatible 802.11a/g/n muntat en rack, inclòs accessoris, configuració i comprovació de funcionament 2.340,00 € u
CAIXA DE XARXA
Fuetó RJ45
12 Fuetó RJ45 de 1,5m Categoria 6/Classe E 4 parells 100 ohm d’un material lliure d’halògens, amb baixa emissió de fum (LSZH) i amb piroretardants. Completament instal·lats i etiquetats 12,60 € u
Plafó de connexionat13 Plafó de 24 connexions RJ45 de 1U Categoria 6/Classe E, per a cables UTP de 4 parells completament instal·lats i etiquetats 495,00 € u
Adaptador
14 Adaptador mestre telefonia bàsica a 100 ohm, instal·lats i etiquetats connectant les regletes d’entrada amb el plafó de connexions de la caixa dexarxa
22,50 € u
Armari
15 Subministrament i instal·lació d’armari rack de paret Rittal QuickBox 21U 600x600, o equivalent, inclòs accessoris i guia cables, 1m de cingladorde connexió al terra, muntat a la paret i connectat al terra elèctric
1.080,00 € u
Regleta BT16 Regleta d’endolls elèctrics Rittal de 7 bases, instal·lada al rack, inclòs accessoris 99,00 € u
MARCUS 2010 - PARTIDES TELECOMUNICACIONS CENTRE CÍVIC CAN LLONG - CASTELLARNAU
CAPITOL 2
Codi Preu unitari Unitat Amidament Preu partida
1 90,00 € u 54,00 4.860,00 €
2 9,00 € u 54,00 486,00 €
3 9,90 € u 90,00 891,00 €
4 4,50 € u 200,00 900,00 €
5 12,70 € u 10,00 127,00 €
6 1,53 € u 60,00 91,80 €
7 1,58 € ml 1600,00 2.528,00 €
8 2.880,00 € u 1,00 2.880,00 €
9 1.170,00 € ml 1,00 1.170,00 €
10 1.080,00 € ml 6,00 6.480,00 €
11 2.340,00 € u 1,00 2.340,00 €
12 12,60 € ml 54,00 680,40 €
13 495,00 € ml 3,00 1.485,00 €
14 22,50 € ml 2,00 45,00 €
15 1.080,00 € ml 1,00 1.080,0 €
16 99,00 € ml 1,00 99,00 €
26.143,20 € Pressupost EXECUCIÓ MATERIAL =
NomPresa de veu/dades d’execució encastada composta per un mecanisme simple tipus RJ45 categoria 6, caixa d’encast i marc enbellidor, inclòs accessoris i connectors. Completament instal·lat i connectat.
Certificació, de tots els punts de veu i dades i preses de telefonia, segons normativa EN50173-1:2002, Categoria 6/Classe E. Lliurant els documents d’homologació i calibrat de l'equipament, i les certificacions, en format electrònic, a la direcció facultativa.
Safata de PVC 200x60 mm amb part proporcional d'unions, accessoris i suports, completament instal·lada
Encaminador (router) Cisco 1900, model 1941/K9, amb dos ports Gigabit Ethernet, 2 ranures d'ampliació EHWIC, 1 ranura d'ampliació ISM, 256MB CF, 512 DRAM. muntat en rack, inclòs accessoris, configuració i comprovació de funcionament
CANALITZACIONS I TUBS
REGISTRES
Punt d’accés sense fil Cisco Aironet 1140, model AIR-LAP1142N-E-K9-Dual-band, per a controlador extern, 802.11a/g/n, muntat a la paret, inclòs accessoris, configuració i comprovació de funcionament
Controlador de xarxa sense fil Cisco 2006 per a 6 punts d’accés i 8 ports Ethernet 10/100, compatible 802.11a/g/n muntat en rack, inclòs accessoris, configuració i comprovació de funcionament
Regleta d’endolls elèctrics Rittal de 7 bases, instal·lada al rack, inclòs accessoris
INFRASTRUCTURA RADIODIFUSIÓ SONORA I TELEVISIÓCAPTACIÓ I CAPÇALERA
DISTRIBUCIÓ I DISPERSIÓ
Adaptador mestre telefonia bàsica a 100 ohm, instal·lats i etiquetats connectant les regletes d’entrada amb el plafó de connexions de la caixa de xarxa
Commutador (switch) Cisco Catalyst 2960, model 2960G-48TC-L, 48 ports ethernet 10/100/1000 4 dels quals son duals SF GE, muntat en rack, inclòs accessoris, configuració i comprovació de funcionament
EQUIPAMENT DE XARXA
Plafó de 24 connexions RJ45 de 1U Categoria 6/Classe E, per a cables UTP de 4 parells completament instal·lats i etiquetats
Canaleta de PVC 30x60mm amb tapa muntada superficialment., amb part proporcional de separadors, accessoris i fixacions, completament instal·lada
Fuetó RJ45 de 1,5m Categoria 6/Classe E 4 parells 100 ohm d’un material lliure d’halògens, amb baixa emissió de fum (LSZH) i amb piroretardants. Completament instal·lats i etiquetats
MARCUS 2010 - PRESSSUPOST TELECOMUNICACIONS CENTRE CÍVIC CAN LLONG - CASTELLARNAU
Tub de PVC de 50mm de diàmetre per a cablejat estructurat, inclòs tot el material de fixació i caixes de derivació, completament instal·lat
Tub de PVC corrugat de 20mm de diàmetre per al cablejat estructurat, inclòs tot el material de fixació i caixes de derivació, completament instal·lat.
Cable UTP Categoria 6/Classe E 4 parells 100 ohm d’un material lliure d’halògens, amb baixa emissió de fum (LSZH) i amb piroretardants. Completament instal·lat.
Subministrament i instal·lació d’armari rack de paret Rittal QuickBox 21U 600x600, o equivalent, inclòs accessoris i guia cables, 1m de cinglador de connexió al terra, muntat a la paret i connectat al terra elèctric
CAPÍTOL 2 INFRAESTRUCTURA RADIODIFUSIÓ SONORA I TELEVISIÓCAPTACIÓ I CAPÇALERA
Codi Nom Preu UnitatSistemes de Captació
1
Antena Yagui UHF, canals 21 a 69. Recepció TV digital. Antena Yagui DAB, banda III. Antena dipol plegat circular omnidireccional FM/BII recepció radiodifusió sonora. Màstil de tub d’acer galvanitzat de 1,5 m longitud, 35 mm diàmetre i 1,5 mm espessor fixat a shunt d'instal·lacions mitjançant 2 esquadres de fixació a obra. Connectat a terres general amb conductor de 25mm2 secció. Esquadres per a paret per al màstil, acer galvanitzat. Totalment instal·lat
279,00 € u
Instal·lacions de Capçalera
2 Equip de capçalera format per 1 mòdul amplificador programable Televes mod.Avant 5, o equivalent, regulable per a banda FM , Banda III, UHF i FI segons esquema d'instal·lació. Totalment programat i ajustat en l'interior del registre de capçalera. 575,10 € u
DISTRIBUCIÓ I DISPERSIÓ
Punt Derivació 2 vies atenuació 15 dB
3Punt Derivació 2 vies atenuació 15 dB Punt de derivació per a RTV terrenal i satèl·lit analògic i digital compost por un derivador direccional blindat de 2 sortides, atenuació 15 dB. Banda de freqüències: 5-2400 MHz. connectors F. Totalment instal·lat
7,20 € u
Punt Distribuïdor de 2 sortides
4 Punt distribuïdor intern de 2 sortides, banda freqüències 5-2400 (TV / FI), connectors F femella, que permet l’intercanvi entre les xarxes de distribució, per a sistemes de TV terrenal, FM y TV satèl·lit analògica i digital. Totalment instal·lat. 8,90 € u
Punt Distribuïdor de 3 sortides
5 Punt distribuïdor intern de 3 sortides, banda freqüències 5-2400 (TV / FI), connectors F femella, que permet l’intercanvi entre les xarxes de distribució, per a sistemes de TV terrenal, FM y TV satèl·lit analògica i digital. Totalment instal·lat. 11,90 € u
Càrrega connector F 75 Ohm6 Carga connector F de 75 Ohm per a col·locar en sortides de derivadors i distribuïdors no utilitzades. 0,67 € u
Cablejat coaxial. TIPUS-1
7 Cable coaxial de 75 ohms, (coberta PVC blanc), d’acord a la norma UNE-EN 50117-5, Cu-Cu. Conductor interior 1,13mm Ø. (16,6 dB/862 MHz i27,5 dB/2150 MHz) per a xarxes de distribució i dispersió de sistemes de TV terrenal, FM i TV satèl·lit analògica i digital, FM i DAB. 0,84 € ml
Presa 2 sortides TV+RD i SAT
8
Presa terminal per a RTV format per caixa de plàstic universal per a empotrar de 64x64x42mm (registre de presa) amb grau de protecció IP 33,5 i rigidesa dielèctrica mínima de 15 kV/mm. Per a fixació de element de connexió de TV. Base de presa de 2 sortides: TV+RD IEC mascle i SAT IEC femella, amb gafes de fixació per a caixa empotrable de Ø56mm. Placa embellidora 80x80mm inclosa. i/p.p de connexió de cable coaxial de xarxa interior, connexions i material auxiliar. Totalment Instal·lada.
8,10 € u
INFRAESTRUCTURA TELEFONIA DISPONIBLE AL PÚBLICCABLATGE
Cable Telefònic 1 parells. Xarxa Exterior9 Cable telefònic de 1 parells de fils de 0,50 mm. Per a xarxa exterior i entrada fins al punt d'interconnexió. 0,20 € ml
PUNT D'INTERCONNEXIÓ
Punt Interconnexió Telefonia 5 parells
10Punt d’ interconnexió de telefonia col·locada en armari de telecomunicacions en Planta Baixa incloent 2 regletes de 10 parells cada una, de inserció per desplaçament d’aïllant amb tall i proba cada una i connexionat de parells per a xarxa de distribució/rack telecomunicacions. Totalment instal·lat.
50,20 € u
INFRAESTRUCTURA CANALITZACIONSARQUETA
Arqueta entrada 40x40x60 prefabricada
11
Arqueta d' entrada prefabricada de Formigó de dimensions interiors 40x40x60 cm. Per a unió entre les xarxes d’alimentació dels diferents operadors i la infraestructura de telecomunicacions de l’edifici, amb finestres per a l’entrada de conductes, tapa amb tanca de seguretat i ancoratges per a tracció i estesa de cables, inclòs excavació en terreny compacte, solera de formigó en massa HM-20 de 10 cm. i p.p. de mitjans auxiliars, embocadura de conductes, replè lateral de terres, transport de terres sobrants a l’abocador inclòs marc i tapa metàl·lics.
325,00 € u
CANALITZACIONS I TUBS
Canal. Externa enterrada 3 Ø63
12
Canalització externa en rasa enterrada, de 30x80 cm. Per a 3 conductes, de PVC de 63 mm. de diàmetre, col·locats en prisma de formigó HM-20 de 6 cm. de recobriment superior i inferior i 7,2 cm. lateralment, inclòs excavació de terres a màquina en terrenys fluixos, tubs, suports distanciadors cada 70 cm, inclòs passada de fil guia en tubs buits., formigó i replenat de la capa superior amb terres procedents de l’excavació, en tongades <25 cm., compactada al 95% del P.N. (sense trencament, ni reposició de vorera).
42,00 € ml
Canal. PVC 1Ø40
13Canalització horitzontal i vertical en muntatge empotrat/fixat a la paret que enllaça les antenes (captació) amb registres intermitjos i armari de Telecomunicacions en Planta Baixa, així com les plantes compreses entre aquests, formada per 1 tub de PVC rígid de 40 mm. Ø, segons UNE 53112 amb grau de protecció IP 33,7 i rigidesa dielèctrica mínima de 15 kV/mm, i/ p.p. de colzes, gafes i peces especials.
25,40 € ml
Canal. PVC Ø25
14Canalització secundaria en muntatge empotrat/fixat a la paret des de l'aramari de Telecomunicacions fins a registre de terminal de xarxa, formada per tub de 25 mm. de diàmetre interior, de PVC corrugat M 25 /gp 7, inclòs gafes de subjecció. 2,31 € ml
Canal. PVC Ø20
15 Canalització interior empotrada/fixada a la paret, formada por 1 tub de PVC corrugat M 20/gp 7, des dels registres terminals o Armari de Telecomunicacions fins els registres de presa d’usuari, per a cada als serveis de RTV, serveis, gafes i p.p. de registres de pas. 1,53 € ml
MARCUS 2010 - PARTIDES TELECOMUNICACIONS CENTRE CÍVIC CAN LLONG - CASTELLARNAU
REGISTRES
Registre 450x450x150
16Registre per a RTV de 45x45x15 cm. format per armari de empotrar/fixar provist de porta o tapa metàl·lica dotat de tancament amb clau, amb reixes de ventil·lació i una rigidesa dielèctrica de 15 KW/mm. , per allotjar l’equip amplificador, derivador i distribuïdor de la xarxa de RTV, i/connexionat i material auxiliar.
170,00 € u
Registre de pas 200x200x100
17 Registre de pas per a RTV de 20x20x10 cm. format per caixa de PVC provist de porta o tapa de tancament mitjançant cargols, una rigidesa dielèctrica de 15 KW/mm. , per pas de canalitzacions de 25 o 20 mm, i/connexionat i material auxiliar. 35,00 € u
ALTRESCable de Cu Flexible 1x25 mm2
18 Cable de coure flexible per interconnexió dels elements de captació de capçalera, registres i aparellatge elèctric present en la Infraestructura de Telecomunicacions. Inclòs connexions, bornes de connexió i connexió a terres general de l'edifici. 4,20 € ml
PARTIDA ESTUDI BÀSIC DE SEGURETAT I SALUT
19 Pressupost de l'ESTUDI BÀSIC DE SEGURETAT I SALUT del projecte de Telecomunicacions (Cablejat Estructural, Telefonia Bàsica, Servei de RTV Terrenal i Satèl·lit) 990,00 € u
PARTIDA IMPREVISTOS20 Partida destinada a treballs imprevistos per a passos d'instal·lacions a través d'elements ja construïts, etc… 550,00 € u
CAPITOL 2
Codi Preu unitari Unitat Amidament Preu partida
1 279,00 € u 1,00 279,00 €
2 575,10 € u 1,00 575,10 €
3 7,20 € u 2,00 14,40 €
4 8,90 € u 1,00 8,90 €
5 11,90 € u 1,00 11,90 €
6 0,67 € u 1,00 1 €
7 0,84 € ml 1,00 0,84 €
8 8,10 € u 7,00 56,70 €
9 0,20 € ml 65,00 13,00 €
10 50,20 € u 1,00 50,20 €
MARCUS 2010 - PRESSSUPOST TELECOMUNICACIONS CENTRE CÍVIC CAN LLONG - CASTELLARNAU
INFRASTRUCTURA RADIODIFUSIÓ SONORA I TELEVISIÓCAPTACIÓ I CAPÇALERA
NomAntena Yagui UHF, canals 21 a 69. Recepció TV digital. Antena Yagui DAB, banda III. Antena dipol plegat circular omnidireccional FM/BII recepció radiodifusió sonora. Màstil de tub d’acer galvanitzat de 1,5 m longitud, 35 mm diàmetre i 1,5 mm espessor fixat a shunt d'instal·lacions mitjançant 2 esquadres de fixació a obra. Connectat a terres general amb conductor de 25mm2 secció. Esquadres per a paret per al màstil, acer galvanitzat. Totalment instal·lat
Equip de capçalera format per 1 mòdul amplificador programable Televes mod.Avant 5, o equivalent, regulable per a banda FM , Banda III, UHF i FI segons esquema d'instal·lació. Totalment programat i ajustat en l'interior del registre de capçalera.
DISTRIBUCIÓ I DISPERSIÓ
Punt Derivació 2 vies atenuació 15 dB Punt de derivació per a RTV terrenal i satèl·lit analògic i digital compost por un derivador direccional blindat de 2 sortides, atenuació 15 dB. Banda de freqüències: 5-2400 MHz. connectors F. Totalment instal·lat
Punt distribuïdor intern de 2 sortides, banda freqüències 5-2400 (TV / FI), connectors F femella, que permet l’intercanvi entre les xarxes de distribució, per a sistemes de TV terrenal, FM y TV satèl·lit analògica i digital. Totalment instal·lat.
Punt distribuïdor intern de 3 sortides, banda freqüències 5-2400 (TV / FI), connectors F femella, que permet l’intercanvi entre les xarxes de distribució, per a sistemes de TV terrenal, FM y TV satèl·lit analògica i digital. Totalment instal·lat.
Carga connector F de 75 Ohm per a col·locar en sortides de derivadors i distribuïdors no utilitzades.
Cable coaxial de 75 ohms, (coberta PVC blanc), d’acord a la norma UNE-EN 50117-5, Cu-Cu. Conductor interior 1,13mm Ø. (16,6 dB/862 MHz i 27,5 dB/2150 MHz) per a xarxes de distribució i dispersió de sistemes de TV terrenal, FM i TV satèl·lit analògica i digital, FM i DAB.
Presa terminal per a RTV format per caixa de plàstic universal per a empotrar de 64x64x42mm (registre de presa) amb grau de protecció IP 33,5 i rigidesa dielèctrica mínima de 15 kV/mm. Per a fixació de element de connexió de TV. Base de presa de 2 sortides: TV+RD IEC mascle i SAT IEC femella, amb gafes de fixació per a caixa empotrable de Ø56mm. Placa embellidora 80x80mm inclosa. i/p.p de connexió de cable coaxial de xarxa interior, connexions i material auxiliar. Totalment Instal·lada.
INFRASTRUCTURA TELEFONIA DISPONIBLE AL PÚBLICCABLATGE
Cable telefònic de 1 parells de fils de 0,50 mm. Per a xarxa exterior i entrada fins al punt d'interconnexió.
PUNT D'INTERCONNEXIÓ
Punt d’ interconnexió de telefonia col·locada en armari de telecomunicacions en Planta Baixa incloent 2 regletes de 10 parells cada una, de inserció per desplaçament d’aïllant amb tall i proba cada una i connexionat de parells per a xarxa de distribució/rack telecomunicacions. Totalment instal·lat.
11 325,00 € u 1,00 325,00 €
12 42,00 € ml 13,00 546,00 €
13 25,40 € ml 20,00 508
14 2,31 € ml 50,00 115,5
15 0,96 € ml 120,00 115,2
16 170,00 € ml 1,00 170
17 35,00 € ml 1,00 35
18 4,20 € ml 12,00 50,4
19 990,00 € u 1,00 990
20 550,00 € u 1,00 550
4.415,81 €
INFRASTRUCTURA CANALITZACIONSARQUETA
Arqueta d' entrada prefabricada de Formigó de dimensions interiors 40x40x60 cm. Per a unió entre les xarxes d’alimentació dels diferents operadors i la infraestructura de telecomunicacions de l’edifici, amb finestres per a l’entrada de conductes, tapa amb tanca de seguretat i ancoratges per a tracció i estesa de cables, inclòs excavació en terreny compacte, solera de formigó en massa HM-20 de 10 cm. i p.p. de mitjans auxiliars, embocadura de conductes, replè lateral de terres, transport de terres sobrants a l’abocador inclòs marc i tapa metàl·lics.
CANALITZACIONS I TUBS
Canalització externa en rasa enterrada, de 30x80 cm. Per a 3 conductes, de PVC de 63 mm. de diàmetre, col·locats en prisma de formigó HM-20 de 6 cm. de recobriment superior i inferior i 7,2 cm. lateralment, inclòs excavació de terres a màquina en terrenys fluixos, tubs, suports distanciadors cada 70 cm, inclòs passada de fil guia en tubs buits., formigó i replenat de la capa superior amb terres procedents de l’excavació, en tongades <25 cm., compactada al 95% del P.N. (sense trencament, ni reposició de vorera).
Canalització horitzontal i vertical en muntatge empotrat/fixat a la paret que enllaça les antenes (captació) amb registres intermitjos i armari de Telecomunicacions en Planta Baixa, així com les plantes compreses entre aquests, formada per 1 tub de PVC rígid de 40 mm. Ø, segons UNE 53112 amb grau de protecció IP 33,7 i rigidesa dielèctrica mínima de 15 kV/mm, i/ p.p. de colzes, gafes i peces especials.
Cable de coure flexible per interconnexió dels elements de captació de capçalera, registres i aparellatge elèctric present en la Infraestructura de Telecomunicacions. Inclòs connexions, bornes de connexió i connexió a terres general de l'edifici.
Pressupost de l'ESTUDI BÀSIC DE SEGURETAT I SALUT del projecte de Telecomunicacions (Cablejat Estructural, Telefonia Bàsica, Servei de RTV Terrenal i Satèl·lit)
Partida destinada a treballs imprevistos per a passos d'instal·lacions a través d'elements ja construïts, etc…
Pressupost EXECUCIÓ MATERIAL =
Canalització secundaria en muntatge empotrat/fixat a la paret des de l'aramari de Telecomunicacions fins a registre de terminal de xarxa, formada per tub de 25 mm. de diàmetre interior, de PVC corrugat M 25 /gp 7, inclòs gafes de subjecció.
Canalització interior empotrada/fixada a la paret, formada por 1 tub de PVC corrugat M 20/gp 7, des dels registres terminals o Armari de Telecomunicacions fins els registres de presa d’usuari, per a cada als serveis de RTV, serveis, gafes i p.p. de registres de pas.
REGISTRES
Registre per a RTV de 45x45x15 cm. format per armari de empotrar/fixar provist de porta o tapa metàl·lica dotat de tancament amb clau, amb reixes de ventil·lació i una rigidesa dielèctrica de 15 KW/mm. , per allotjar l’equip amplificador, derivador i distribuïdor de la xarxa de RTV, i/connexionat i material auxiliar.
Registre de pas per a RTV de 20x20x10 cm. format per caixa de PVC provist de porta o tapa de tancament mitjançant cargols, una rigidesa dielèctrica de 15 KW/mm. , per pas de canalitzacions de 25 o 20 mm, i/connexionat i material auxiliar.
ALTRES
TOTAL PRESSUPOST D’EXECUCIÓ MATERIAL 30.559,01 €
Despeses generals (13 % sobre el P.E.M.) ................................................................. 3.972,67 €
B fi i i d t i l (6 % b l P E M ) 1 833 54 €
ÚLTIM FULL
Benefici industrial (6 % sobre el P.E.M.) .................................................................... 1.833,54 €
Subtotal 36.365,22 €
I.V.A. (16 % sobre el Subtotal) .................................................................................. 5.818,44 €
TOTAL PRESSUPOST D‘EXECUCIÓ ................................................................. 42.183,66 €
Aquest pressupost ascendeix a la quantitat de QUARANTA DOS MIL CENTVUITANTA-TRES EUROS AMB SEIXANTA SIS CÈNTIMS.
Òdena, Gener de 2010
Signat: Francesc Romà Frigolé Marc Guitart i Garcia Enginyer de Telecomunicació Eng.Tèc. Telecomunicacions (esp. Imatge i so) Col·legiat Num. 12.461 Col: 10.460