19
Remove HF from BF 3 Ma Chunlei

Remove HF from BF 3 Ma Chunlei

  • Upload
    ansel

  • View
    50

  • Download
    0

Embed Size (px)

DESCRIPTION

Remove HF from BF 3 Ma Chunlei. Reference 1: 柳彤 , 氟化钠吸附氟化氢最佳工艺参数测定 [J]. 舰船科学技术 , 2009, 31(2): 109-111. Content: Qualitative research: performance of HF adsorption on NaF pellets; Quantitative research: inlet concentration; inlet temperature; inlet pressure. Chemical adsorption: - PowerPoint PPT Presentation

Citation preview

Page 1: Remove HF from BF 3 Ma Chunlei

Remove HF from BF3

Ma Chunlei

Page 2: Remove HF from BF 3 Ma Chunlei

Reference 1: 柳彤 , 氟化钠吸附氟化氢最佳工艺参数测定 [J]. 舰船科学技术 , 2009, 31(2): 109-111.

Content:Qualitative research: performance of HF adsorption on NaF pellets;Quantitative research: inlet concentration; inlet temperature; inlet pressure.

Page 3: Remove HF from BF 3 Ma Chunlei

Chemical adsorption: NaF + HF NaHF2

Reversible reaction:T>250 ℃ (280℃-300℃)

NaHF2 NaF + HF

Page 4: Remove HF from BF 3 Ma Chunlei

Fig. 1 Flow chart of adsorbent experiment

Page 5: Remove HF from BF 3 Ma Chunlei
Page 6: Remove HF from BF 3 Ma Chunlei

Conclusion:

Fig. 2 Impact of temperature to efficiency

Page 7: Remove HF from BF 3 Ma Chunlei

Conclusion:

Fig. 3 Impact of pressure to efficiency

Page 8: Remove HF from BF 3 Ma Chunlei

Conclusion:

Fig. 4 Impact of flux to efficiency

Page 9: Remove HF from BF 3 Ma Chunlei

Reference 2: Afzal. S. & Rahimi. A. (2010). Experimental study of hydrogen fluoride adsorption on sodium fluoride. Journal of Industrial and Engineering Chemistry. 16, 147-151.

Purpose : Remove HF in F2

Page 10: Remove HF from BF 3 Ma Chunlei

Material :An adsorption column is made from stainless steel;A cylindrical shell is installed around the adsorption column;The outlet HF concentration is measured by a UV-IR analyzer;101-L capsule-Pure and vapor-free HF and N2

Nitrogen gas as inert;Sodium fluoride pellets;

Page 11: Remove HF from BF 3 Ma Chunlei
Page 12: Remove HF from BF 3 Ma Chunlei

Tips:A constant flow rate;Water pass through the shell;The outlet concentration recorded continuously;Until the bed completely saturated;The inlet concentration of HF:2~15mol%;The experiments conducted at 22 and 54℃.

Page 13: Remove HF from BF 3 Ma Chunlei

Table 1Experimental conditions and results for column test runs.

Page 14: Remove HF from BF 3 Ma Chunlei

Fig. 2. Hydrogen fluoride isotherms on sodium fluoride at 22 and 54 ℃

Page 15: Remove HF from BF 3 Ma Chunlei

Fig. 3. Breakthrough curve of hydrogen fluoride adsorption on sodium fluoride.

Page 16: Remove HF from BF 3 Ma Chunlei

Fig. 4. Effect of temperature on the breakthrough curves of HF adsorption on NaF pellets.

Page 17: Remove HF from BF 3 Ma Chunlei

The breakthrough curves of HF adsorption on NaF pellets for different inlet concentrations.

Page 18: Remove HF from BF 3 Ma Chunlei

• Reference 3: Afzal. S. & Rahimi. A. (2010). Modeling hydrogen fluoride adsorption by sodium fluoride. Journal of Industrial and Engineering Chemistry. 16, 978-985.

• While the feed gas velocity decreases, the HF adsorption capacity on NaF is significantly enhanced and there is a delay in breakthrough time.

• The adsorption capacity of HF on NaF decreases slightly when inlet HF concentration increases.

Page 19: Remove HF from BF 3 Ma Chunlei