RESISTENCIA DE LOS CONDUCTORES CALIBRE AWG 1/0 R = p L/A p = resistividad L = longitud A = área Ǿ = diámetro RESISTENCIA DEL COBRE (CU) RESISTENCIA DEL ALUMINIO (AL) p CU = 0.0172 Ω/m/mm² Ǿ = 8.25 mm L = 1098644.813 m A = π (Ǿ/2)² A = π (8.25 mm/2)² A = 53.45 mm² R = 1098644.813 m X 0.0172 Ω/m/mm² 53.45 mm² R = 353.5395844 Ω p AL = 0.028 Ω/m/mm² Ǿ = 8.25 mm L = 1098644.813 m A = 53.45 mm² R = 1098644.813 m X 0.028 Ω/m/mm² 53.45 mm² R = 575.5295559 Ω

RESISTENCIA DE CONDUCTORES

Embed Size (px)

DESCRIPTION

RESISTIVIDAD DE DOS CONDUCTORES CU-AL

Citation preview

Page 1: RESISTENCIA DE CONDUCTORES

RESISTENCIA DE LOS CONDUCTORES

CALIBRE AWG 1/0

R = p L/A

p = resistividad L = longitud A = área Ǿ = diámetro

RESISTENCIA DEL COBRE (CU) RESISTENCIA DEL ALUMINIO (AL)p CU = 0.0172 Ω/m/mm²Ǿ = 8.25 mmL = 1098644.813 mA = π (Ǿ/2)² A = π (8.25 mm/2)²A = 53.45 mm²

R = 1098644.813 m X 0.0172 Ω/m/mm² 53.45 mm²

R = 353.5395844 Ω

p AL = 0.028 Ω/m/mm²Ǿ = 8.25 mmL = 1098644.813 mA = 53.45 mm²

R = 1098644.813 m X 0.028 Ω/m/mm² 53.45 mm²

R = 575.5295559 Ω