Upload
debora-testa
View
226
Download
2
Embed Size (px)
Citation preview
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceService
RinNOVA RinNOVA
SOLAR INSOLAR IN
Gestione zoneGestione zone
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceSCHEMA IDRAULICO DI PRINCIPIOSCHEMA IDRAULICO DI PRINCIPIO
• IL SISTEMAIL SISTEMA RinNOVA SOLAR IN RinNOVA SOLAR IN PUO’ ESSERE DOTATO DI PUO’ ESSERE DOTATO DI COMPENSATORE IDRAULICO PER LA COMPENSATORE IDRAULICO PER LA GESTIONE DI 3 ZONE GESTIONE DI 3 ZONE RISCALDAMENTO.RISCALDAMENTO.
• A SECONDA DEL PACCHETTO A SECONDA DEL PACCHETTO SCELTO SONO DISPONIBILI:SCELTO SONO DISPONIBILI:– KIT 2 ZONE ATKIT 2 ZONE AT– KIT 2 ZONE BTKIT 2 ZONE BT– KIT 1 ZONA AT + 1 ZONA BTKIT 1 ZONA AT + 1 ZONA BT– KIT 1 ZONA AT + 2 ZONE BTKIT 1 ZONA AT + 2 ZONE BT– KIT NESSUNA ZONAKIT NESSUNA ZONA
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceService
I VARI KIT SONO COSI’ COMPOSTII VARI KIT SONO COSI’ COMPOSTI• KIT 2 ZONE ATKIT 2 ZONE AT
– N° 2 POMPE ASKOLL 15-60/130, 220V, 65 WN° 2 POMPE ASKOLL 15-60/130, 220V, 65 W• KIT 2 ZONE BTKIT 2 ZONE BT
– N° 2 POMPE ASKOLL 15-60/130, 220V 65 WN° 2 POMPE ASKOLL 15-60/130, 220V 65 W– N°2 MISCELATRICI, 220 V, 1 WN°2 MISCELATRICI, 220 V, 1 W– NTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONANTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONA
• KIT 1 ZONA AT + 1 ZONA BTKIT 1 ZONA AT + 1 ZONA BT– N°2 POMPE ASKOLL 15-60/130, 220 V 65 WN°2 POMPE ASKOLL 15-60/130, 220 V 65 W– N°1 MISCELATRICE, 220 V, 1 WN°1 MISCELATRICE, 220 V, 1 W– NTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONANTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONA
• KIT 1 ZONA AT + 2 ZONE BTKIT 1 ZONA AT + 2 ZONE BT– N°3 POMPE ASKOLL 15-60/130, 220V, 65 WN°3 POMPE ASKOLL 15-60/130, 220V, 65 W– N°2 MISCELATRICI , 220 V, 1 WN°2 MISCELATRICI , 220 V, 1 W– NTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONANTC + TERMOSTATO MAX TEMPERATURA SU TUBI MANDATA ZONA
• KIT NESSUNA ZONAKIT NESSUNA ZONA– TUBI MANTATA IMPIANTOTUBI MANTATA IMPIANTO
• TUTTI I KIT SONO DOTATI DI CENTRALINA GESTIONE ZONE TUTTI I KIT SONO DOTATI DI CENTRALINA GESTIONE ZONE
COMPONENTI DEL KIT DISTRIBUZIONECOMPONENTI DEL KIT DISTRIBUZIONE
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceService
COMPITOCOMPITO• SEPARARE IDRAULICAMENTE IL SEPARARE IDRAULICAMENTE IL
CIRCUITO RISCALDAMENTO PRIMARIO CIRCUITO RISCALDAMENTO PRIMARIO DAL CIRCUITO DI DISTRIBUZIONEDAL CIRCUITO DI DISTRIBUZIONE;
• PERMETTE DI DIFFERENZIARE LE PERMETTE DI DIFFERENZIARE LE PORTATE PER LE VARIE ZONEPORTATE PER LE VARIE ZONE
• IL SUO PRINCIPIO IDRAULICO IL SUO PRINCIPIO IDRAULICO PERMETTE, SENZA PARTICOLARI PERMETTE, SENZA PARTICOLARI SISTEMI DI TARATURA, UNA BUONA SISTEMI DI TARATURA, UNA BUONA INDIPENDENZA TRA TUTTI I VARI INDIPENDENZA TRA TUTTI I VARI CIRCUITICIRCUITI
CARATTERISTICHECARATTERISTICHE• LA SUA PARTICOLARE CONFORMAZIONE LA SUA PARTICOLARE CONFORMAZIONE
INTERNA PERMETTE UNA MIGLIOR INTERNA PERMETTE UNA MIGLIOR MISCELAZIONE DI TRA MANDATA E MISCELAZIONE DI TRA MANDATA E RITORNO ED EVITA “INQUINAMENTI” RITORNO ED EVITA “INQUINAMENTI” TRA I VARI CIRCUITI COLLEGATI TRA I VARI CIRCUITI COLLEGATI
COMPENSATORE IDRAULICOCOMPENSATORE IDRAULICO
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceService
COMPITOCOMPITO• MISCELARE ACQUA RITORNO MISCELARE ACQUA RITORNO
IMPIANTO E ACQUA DEL IMPIANTO E ACQUA DEL COMPENSATORE IN BASE AI CALCOLI COMPENSATORE IN BASE AI CALCOLI DELLA SCHEDA GESTIONE ZONEDELLA SCHEDA GESTIONE ZONE;
CARATTERISTICHECARATTERISTICHE• 220 V, 1 W, ALIMENTATA A TRE FILI220 V, 1 W, ALIMENTATA A TRE FILI• MANOPOLA REGOLAZIONE BY PASS MANOPOLA REGOLAZIONE BY PASS
SEMPRE CHIUSASEMPRE CHIUSA• IL PASSAGGIO DELL’ACQUA DA IL PASSAGGIO DELL’ACQUA DA
RITORNO A MANDATA RITORNO A MANDATA RISCALDAMENTO E’ GARANTITO DA RISCALDAMENTO E’ GARANTITO DA UN CANALE TARATOUN CANALE TARATO
VALVOLA MISCELATRICEVALVOLA MISCELATRICE
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceVALVOLA MISCELATRICEVALVOLA MISCELATRICE
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceCIRCOLAZIONI ZONE MISCELATECIRCOLAZIONI ZONE MISCELATE
VISTA GRUPPO DISTRIBUZIONE IN SEZIONEVISTA GRUPPO DISTRIBUZIONE IN SEZIONE• L’OTTURATORE DELLA MISCELATRICE E’ NORMALMENTE CHIUSOL’OTTURATORE DELLA MISCELATRICE E’ NORMALMENTE CHIUSO• A FRONTE DI UNA RICHIESTA DALLA ZONA MISCLELATA L’OTTURATORE A FRONTE DI UNA RICHIESTA DALLA ZONA MISCLELATA L’OTTURATORE
INIZIA AD APRIRSI PER MISCELARE L’ACQUA CALDA DEL INIZIA AD APRIRSI PER MISCELARE L’ACQUA CALDA DEL COMPENSATORE CON QUELLA FREDDA DEL RITORNO COMPENSATORE CON QUELLA FREDDA DEL RITORNO
NON RITORNONON RITORNO
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceCIRCOLAZIONE ZONE DIRETTECIRCOLAZIONE ZONE DIRETTE
VISTA GRUPPO DISTRIBUZIONE IN SEZIONEVISTA GRUPPO DISTRIBUZIONE IN SEZIONE• A FRONTE DI UNA RICHIESTA DALLA ZONA ATA A FRONTE DI UNA RICHIESTA DALLA ZONA ATA
TEMPERATURA VIENE ALIMENTATO IL CIRCOLATORE CHE TEMPERATURA VIENE ALIMENTATO IL CIRCOLATORE CHE SPILLA ACQUA CALDA DIRETTAMENTE DAL COMPENSATORE SPILLA ACQUA CALDA DIRETTAMENTE DAL COMPENSATORE
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceDATI TECNICIDATI TECNICI
ZONA MISCELATAZONA MISCELATA• RANGE: 25-45 °CRANGE: 25-45 °C• T.MAX: 55 ° CT.MAX: 55 ° C
ZONA MISCELATAZONA MISCELATA• RANGE: 25-45 °CRANGE: 25-45 °C• T.MAX: 55 ° CT.MAX: 55 ° C
ZONA DIRETTA ZONA DIRETTA • RANGE: 30-80 °CRANGE: 30-80 °C• T.MAX: NON PRESENTET.MAX: NON PRESENTE
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceCOLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICI
COLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICIVANNO REALIZZATI I SEGUENTI COLLEGAMENTI (Indicati in rosso nello schema):VANNO REALIZZATI I SEGUENTI COLLEGAMENTI (Indicati in rosso nello schema):• ALIMENTAZIONE ELETTRICAALIMENTAZIONE ELETTRICA• SONDA ESTERNA E COMANDO REMOTO ZONA 1 BT (FORNITO DI SERIE)SONDA ESTERNA E COMANDO REMOTO ZONA 1 BT (FORNITO DI SERIE)• LINEA SERIALE TRA SCHEDA GESTIONE ZONE (SCHEDA INTERFACCIA) E CALDAIA (LINEA COMANDO LINEA SERIALE TRA SCHEDA GESTIONE ZONE (SCHEDA INTERFACCIA) E CALDAIA (LINEA COMANDO
REMOTO)REMOTO)• COMANDI REMOTO OPTIONAL E/O CRONOTERMORMOSTATI PER ZONE 2 E 3COMANDI REMOTO OPTIONAL E/O CRONOTERMORMOSTATI PER ZONE 2 E 3
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServiceCOLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICI
COLLEGAMENTI ELETTRICI MULTIREMOTOCOLLEGAMENTI ELETTRICI MULTIREMOTO• SE SI COLLEGANO PIU’ COMANDI REMOTI, QUESTI DEVONO ESSERE SE SI COLLEGANO PIU’ COMANDI REMOTI, QUESTI DEVONO ESSERE
COLLEGATI IN SERIE TRA DI LOROCOLLEGATI IN SERIE TRA DI LORO
•UNA VOLTA INSTALLATI E’ NECESSARIO SETTARE UNA VOLTA INSTALLATI E’ NECESSARIO SETTARE IL PARAMETRO “ZONE” SU OGNI REMOTOIL PARAMETRO “ZONE” SU OGNI REMOTO
•IL REMOTO CHE AVRA’ IL PARAMETRO “ZONE = IL REMOTO CHE AVRA’ IL PARAMETRO “ZONE = 1” (OBBLIGATORIAMENTE ZONA IN BASSA 1” (OBBLIGATORIAMENTE ZONA IN BASSA TEMPERATURA) PRENDERA’ LA FUNZIONE DI TEMPERATURA) PRENDERA’ LA FUNZIONE DI REMOTO MASTER E QUINDI L’UNICO CHE REMOTO MASTER E QUINDI L’UNICO CHE CONTROLLERA’ LA CALDAIACONTROLLERA’ LA CALDAIA
RinNOVA SOLAR IN: GESTIONE ZONERinNOVA SOLAR IN: GESTIONE ZONE
ServiceServicePRINCIPIO DI FUNZIONAMENTOPRINCIPIO DI FUNZIONAMENTO
TERMOREGOLAZIONETERMOREGOLAZIONEIL SISTEMA E’ DOTATO DI SERIE DI:IL SISTEMA E’ DOTATO DI SERIE DI:• SONDA ESTERNA (DA COLLEGARE ALLA CENTRALINA GESTIONE ZONE)SONDA ESTERNA (DA COLLEGARE ALLA CENTRALINA GESTIONE ZONE)• N°1 COMANDO REMOTO PER GESTIONE TEMPERATURA AMBIENTE ZONA 1 (DA COLLEGARE ALLA CENTRALINA GESTIONE N°1 COMANDO REMOTO PER GESTIONE TEMPERATURA AMBIENTE ZONA 1 (DA COLLEGARE ALLA CENTRALINA GESTIONE
ZONE OBBLIGATORIAMENTE PER GESTIRE UNA ZONA BASSA TEMPERATURA);ZONE OBBLIGATORIAMENTE PER GESTIRE UNA ZONA BASSA TEMPERATURA);• SOLO IL COLLEGAMENTO DI ALMENO UN COMANDO REMOTO PUO’ ATTIVARE LA COMUNICAZIONE SERIALE TRA SCHEDA SOLO IL COLLEGAMENTO DI ALMENO UN COMANDO REMOTO PUO’ ATTIVARE LA COMUNICAZIONE SERIALE TRA SCHEDA
GESTIONE ZONE E CALDAIA;GESTIONE ZONE E CALDAIA; • GRAZIE ALLA COMUNICAZIONE SERIALE LA CALDAIA IMPOSTA LA TEMPERATURA DI MANDATA AL COMPENSATORE IN GRAZIE ALLA COMUNICAZIONE SERIALE LA CALDAIA IMPOSTA LA TEMPERATURA DI MANDATA AL COMPENSATORE IN
FUNZIONE DI QUALE ZONA CHIEDE POTENZA.FUNZIONE DI QUALE ZONA CHIEDE POTENZA.
• LA LETTURA DELLA SONDA ESTERNA LA LETTURA DELLA SONDA ESTERNA PERMETTE ALLA SCHEDA GESTIONE ZONE PERMETTE ALLA SCHEDA GESTIONE ZONE DI FAR LAVORARE LA MISCELATRICE.DI FAR LAVORARE LA MISCELATRICE.
• L’INSTALLAZIONE DI ALTRI COMANDI L’INSTALLAZIONE DI ALTRI COMANDI REMOTI E’ OPZIONALEREMOTI E’ OPZIONALE