14
Schutzvermerk nach DIN 34 beachten Handling 2 XControl XC600 XC600: Handling

Schutzvermerk nach DIN 34 beachten Handling 2 XControl XC600 XC600: Handling

Embed Size (px)

Citation preview

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Handling

2

XControl XC600

XC600: Handling

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

XC600: Assembly

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Address setting of the optional modules

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Comfortable diagnosis and handling even

without programming tool or external visualisation

4 lines with 12 digits

Choice of menue by turning1

Confirm by pushing

2

Cursor blinks

XControl: Display + Menu selection button

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

PACK_8=ONHAUBE_2=AUFAUSSCHUSS=7

Diagnosis

Program

Receipt

Device

System

Back

Main Menu

User-specific DisplayBasic menue

Turn

Push

XControl: The Menus

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

!

! = non-acknoledged event

PLC mode

Loaded program

Informed at a

glance

Push: To main menu

Turn: To user-specific display

Position Function selector switch

S = Stop

P = Run-P

R = Run

XControl: The Basic Menu

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Control sends strings to display

3

When programming: Choice of important variables , definition of strings

1XSoft

PACK_8=ONHAUBE_2=AUFAUSSCHUSS=7

Within each control cycle: interrogation of

chosen variables

2

Actual and specific information at a glance

XControl: User-specific display

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Displays errors and events

Reset, Copy, aktivate, Load, Delete

Define IP address, date/time, security, language, hardware configuration, software version

Shut down, new start

Back to basic menu

Diagnosis

Program

Receipt

Device

System

Back

Logic menu paths: Quick finding without manual

XControl: Main menu

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Error diagnosis:

All non-acknoledged program errors are shown with time of occurance

Battery empty, hardware module missing, program missing …

List of events:

Has the program been running without problems?

Was it stopped or started? When was that?

Starts / Stops

Strong support while commissioning, servicing

and operating

XControl: Menu diagnosis

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

INTERNAL

EXTERNAL

RAM

Compact Flash (Plug-in at operation module)

Flash Disk (Hard memory on CPU

module)

Activated program /

receipt

ACTIVATE

LOAD

Program / receipt

RUN /

RUN-P

Simple and safe data management and program starting

COPY

Loaded program /

receipt

Start

STOP

Program / recipe

XControl: Menus „Program“ und „Recipe“

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Activate

Password

Security

Function selector switch at RUN

Device

Activating password via menus

+

Securing after commissioningProtection against unautorized menu

manipulation

Access only to Basic Menu and

User-specific Menu

“Lock switch”: Protection against unauthorized swich operation

Display shows: “Function

selector swich at RUN!”

Protection against unauthorized programming

Programming only with switch

position RUN-P

XControl: Security

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

When performing a RESET some data is to be put back to its initial values while other data shall maintain their values

Example: Feed data of a shaft

Example: Statistic data

... are maintained

... are reset

VAR Persistant

... are maintained... are reset

... are maintained... are maintained

VAR Retain PersistantVAR Retain

WARM

COLD

Safe starts through correct initialization

STOP RUN RUN

M-RES

1

2 Within XSoft variables are declared precisely

3

Resets during operation bring about the desired initialization

Or power cycle

XControl: Menu „Program“ – Reset functionality

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

SECURITY

Define password

Other network participants

GATEWAY Define IP address

IP ADDRESS

Definition as network participant

SUBNETMASK

NAME

SOFTWARE Interrogation of actual version

DATE / TIME

LANGUAGE (English, German, Italian, French)

Efficient configuration and

interrogation

HARDWARE Interrogation of actual modules

Router

XControl: Menu „Device“

Sch

utz

verm

erk

na

ch D

IN 3

4 b

eac

hte

n

Operation

Removal or malfunction of a

hardware module

TimeCommissioning

AUTOcONFIG = OFF

“Freeze” of nominal configuration Error reported

SF-LED shows red

Perfect supervision of hardware

XControl: Menu „Device“ – Hardware configuration