2
SKIOLDGROUP · Denmark · Tel: +45 99 89 88 87 · www.skiold.com · [email protected] SKIOLD DAMAS DK-5250 Odense SV Tel.: +45 99 89 88 87 Email: [email protected] www.skiold.com/seed SKIOLDDAMAS SKIOLD DAMAS PULCO SKIOLD MAKES THE DIFFERENCE!

SKIOLD DAMAS PULCO · 2019-04-04 · Damas A/S | Industrivej 2, V. Aaby | DK-5600 Faaborg | Tel +45 63 61 82 00 | Fax +45 62 61 68 51 [email protected] | PULCO DATA - 1 / 1 Function

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SKIOLD DAMAS PULCO · 2019-04-04 · Damas A/S | Industrivej 2, V. Aaby | DK-5600 Faaborg | Tel +45 63 61 82 00 | Fax +45 62 61 68 51 mail@damas.com | PULCO DATA - 1 / 1 Function

SKIOLDGROUP · Denmark · Tel: +45 99 89 88 87 · www.skiold.com · [email protected]

SKIOLDGROUP

SKIOLD DAMAS • DK-5250 Odense SV • Tel.: +45 99 89 88 87 • Email: [email protected] • www.skiold.com/seed

SKIOLDDAMAS

SKIOLD DAMAS PULCO

SKIOLD MAKES THE DIFFERENCE!

Page 2: SKIOLD DAMAS PULCO · 2019-04-04 · Damas A/S | Industrivej 2, V. Aaby | DK-5600 Faaborg | Tel +45 63 61 82 00 | Fax +45 62 61 68 51 mail@damas.com | PULCO DATA - 1 / 1 Function

Damas A/S | Industrivej 2, V. Aaby | DK-5600 Faaborg | Tel +45 63 61 82 00 | Fax +45 62 61 68 51

[email protected] | www.damas.com

PULCO DATA - 1 / 1

Function The raw material is delivered through the inlet (1) to themotor-driven distributor (2), which by its rotating actionpasses the raw material evenly through the vertical airstream to the bottom outlet (3).The fan draws in air verticallyupwards through inlet (4) at which time separating the lightimpurities from the grain in the air stream. After which theselights are blown through the fan to the cyclone (5).The airfrom the cyclone can either be carried out into the open air(open air system) or be returned to the air intake (4) througha branch pipe to be carried off through a filter.

Specifications 80 80 S 80 F 120 120 S 120 F

Cyclone type UC 110 110 60 140 140 110

Motor, fan kW 5.5 5.5 4.0 7.5 7.5 5.5

Motor, distributor kW 0.37 0.37 0.37 0.37 0.37 0.37

Motor, rotary seal kW 0.55 0.55 0.55 0.55 0.55 0.55

Max. power consumption kW 5.9 5.9 5.9 7.9 7.9 7.9

Quantity of air, open air system m3/h 5500 5500 3600 8300 8300 5500

Quantity of air, recycling system m3/h 1500 1500 900 2000 2000 1400

Diameter mm 910 910 910 1150 1150 1150

Height without fan mm 2060 2060 2060 2310 2310 2310

Weight kg 285 345 345 430 500 500

Specifications 150 S 180 S 250 S 250 F 300 S 300 F

Cyclone type UC 160 2 × 110 2 × 140 140 3 × 160 2 × 140

Motor, fan kW 7.5 2 × 5.5 2 × 7.5 7.5 3 × 7.5 2 × 7.5

Motor, distributor kW 0.37 0.55 0.55 0.55 0.55 0.55

Motor, rotary seal kW 0.55 2 × 0.55 2 × 0.55 0.55 3 × 0.55 2 × 0.55

Max. power consumption kW 8.1 11.6 15.8 23.1

Quantity of air, open air system m3/h 9500 11000 16600 8300 28500 16600

Quantity of air, recycling system m3/h 2400 2800 4000 2000 7200 4000

Diameter mm 1150 1640 2160 2160 2160 2160

Height without fan mm 2710 3490 3450 3450 4070 4070

Weight kg 500 625 850 850 850 850

80 80 S 80 F 120 120 S 120 F

110 110 60 140 140 110

5.5 5.5 4.0 7.5 7.5 5.5

0.37 0.37 0.37 0.37 0.37 0.37

0.55 0.55 0.55 0.55 0.55 0.55

5.9 5.9 5.9 7.9 7.9 7.9

5500 5500 3600 8300 8300 5500

1500 1500 900 2000 2000 1400

910 910 910 1150 1150 1150

2060 2060 2060 2310 2310 2310

285 345 345 430 500 500

150 S 180 S 250 S 250 F 300 S 300 F

160 2 × 110 2 × 140 140 3 × 160 2 × 140

7.5 2 × 5.5 2 × 7.5 7.5 3 × 7.5 2 × 7.5

0.37 0.55 0.55 0.55 0.55 0.55

0.55 2 × 0.55 2 × 0.55 0.55 3 × 0.55 2 × 0.55

8.1 11.6 15.8 23.1

9500 11000 16600 8300 28500 16600

2400 2800 4000 2000 7200 4000

1150 1640 2160 2160 2160 2160

2710 3490 3450 3450 4070 4070

500 625 850 850 850 850

Dam

as D

ata

shee

t. 12

7 98

6 20

3 00

9_01

. 25-

02-2

019.

SKIOLD DAMAS PULCO

SKIO

LD A

/S •

CVR

: DK

57 0

8 11

12 S

æby

• Al

l Rig

hts

Rese

rved

.

TECHNICAL SPECIFICATIONS

Cyclone type UC:

Motor, fan (kW):

Motor, distributor (kW):

Motor, rotary seal (kW):

Max. power consumption (kW):

Quantity of air, open air system (m³/h):

Quantity of air, recycling system (m³/h):

Diameter (mm):

Height without fan (mm):

Weight (kg):

Cyclone type UC:

Motor, fan (kW):

Motor, distributor (kW):

Motor, rotary seal (kW):

Max. power consumption (kW):

Quantity of air, open air system (m³/h):

Quantity of air, recycling system (m³/h):

Diameter (mm):

Height without fan (mm):

Weight (kg):

Function

The raw material is delivered through the inlet (1) to the motor-driven distributor (2), which by its rotating action passes the raw material evenly through the vertical air stream to the bot-tom outlet (3). The fan draws in air vertically upwards through inlet (4) at which time separating the light impurities from the grain in the air stream. After which these lights are blown through the fan to the cyclone (5). The air from the cyclone can either be carried out into the open air (open air system) or be returned to the air intake (4) through a branch pipe to be carried off through a filter.