  • 8828 S. Archer Ave. Willow Springs, IL 60480 office 708.839.6840 fax 708.839.0324 toll-free 888.4.GEMCOM www.gemcom.com Custom Graphic & Directory Annunciators Custom Fire Alarm & Suppression Devices

    Custom Switches Custom Signage Safety Products

    The City Tie Disconnect Panel combines 3 separate switch assemblies in one complete panel to simplify installation and wiring near the Fire Alarm Panel. The City Tie Disconnect Switch is used to disconnect the Fire Alarm Panel from reporting any Alarm or Trouble Condition to the City in order to test and maintain the Fire Alarm System. When the switch is turned to the Disconnect position, a White Pilot light illuminates to inform the user that the Panel has been disconnected. The City Tie Trouble Bell will ring and can be silenced using the City Tie Trouble Station to the right of the Disconnect Switch

    Both the Fire Alarm Trouble and City Tie Trouble Stations work the same way. In the BELL NORMAL position, the BELL TEST will sound the bell. When there is a trouble, the bell will sound. Switching the toggle to the BELL SILENCE position will silence the bell and the Bell Silenced LED will illuminate. When the trouble clears, the LED will turn off and a ring back will sound until the BELL SILENCE switch is returned to the normal position.

    CITY TIE DISCONNECT PANEL Effective May 2010 PART# GEM CBC-DC-KIT Specify BLACK or RED Faceplate Negative Common page 1 of 3

  • CITY TIE DISCONNECT PANEL Effective May 2010 PART# GEM CBC-DC-KIT Specify BLACK or RED Faceplate Negative Common page 2 of 3

    8828 S. Archer Ave. Willow Springs, IL 60480 office 708.839.6840 fax 708.839.0324 toll-free 888.4.GEMCOM www.gemcom.com Custom Graphic & Directory Annunciators Custom Fire Alarm & Suppression Devices

    Custom Switches Custom Signage Safety Products

    The City Tie Disconnect Panel operates on 24VDC. It comes wired with a negative common. Positive is available upon request. The panel can also have a module used to disconnect the City Tie if requested.

    -

    CIT

    Y T

    IE

    +2

    4 V

    DC

    -24 V

    DC

    TO

    BE

    LL

    -24V

    DC

    IN

    &

    CT

    TR

    BL

    BE

    LL

    NO

    T D

    ISC

    ON

    .

    CT

    TR

    BL

    BE

    LL

    DIS

    CO

    N. O

    NL

    Y

    + 2

    4V

    DC

    WH

    EN

    CT

    TR

    BL

    BE

    LL

    OF

    BE

    LL

    TO

    +24V

    DC

    CT

    TR

    BL

    BE

    LL

    TO

    BE

    LL

    -24V

    DC

    IN

    &

    FA

    TR

    BL

    BE

    LL

    FO

    R IN

    TB

    L

    +24 E

    XC

    EP

    T

    FA

    TR

    BL

    BE

    LL

    IN T

    BL

    ON

    LY

    +24

    VD

    C

    FA

    TR

    BL

    BE

    LL

    OF

    BE

    LL

    TO

    +24V

    DC

    FA

    TR

    BL

    BE

    LL

    19

    18

    17

    16

    15

    14

    13

    12

    11

    10 9 8 7

    +24

    VD

    C

    IN P A N E LR E L A Y

    F A T R O U B L E

    B E L L B E L L

    1

    RE

    MO

    TE

    CT

    TR

    BL

    BE

    LL

    2

    RE

    MO

    TE

    CT

    TR

    BL

    BE

    LL

    3

    RE

    MO

    TE

    CT

    TR

    BL

    BE

    LL

    1

    RE

    MO

    TE

    FA

    TR

    BL

    BE

    LL

    2

    RE

    MO

    TE

    FA

    TR

    BL

    BE

    LL

    3

    RE

    MO

    TE

    FA

    TR

    BL

    BE

    LL

    6 5 4 3 2 1

    +

    CIT

    Y T

    IE

    +

    CIT

    Y T

    IE

    CIT

    Y T

    IE -

    TO

    CIT

    Y B

    OX

    CIT

    Y T

    IE +

    FR

    OM

    FA

    CP

    CIT

    Y T

    IE +

    TO

    CIT

    Y B

    OX

    + 2

    4 V

    DC

    FR

    OM

    FA

    CP

    - 24 V

    DC

    FR

    OM

    FA

    CP

    20

    D G P D G PD G P D G P

    SA

    PR

    E

    IN

    OU

    T

  • 8828 S. Archer Ave. Willow Springs, IL 60480 office 708.839.6840 fax 708.839.0324 toll-free 888.4.GEMCOM www.gemcom.com Custom Graphic & Directory Annunciators Custom Fire Alarm & Suppression Devices

    Custom Switches Custom Signage Safety Products

    This literature is provided for informational purposes only. Gemcom, INC. assumes no responsibility for the products suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact GEMCOM, INC., WILLOW SPRINGS, IL 60480. Telephone: (708) 839-6840

    CITY TIE DISCONNECT PANEL Effective May 2010 PART# GEM CBC-DC-KIT Specify BLACK or RED Faceplate Negative Common page 3 of 3

    The City Tie Disconnect Panel comes with a separate back box that can be shipped by a distributor without the door and back plate, for rough in installation. The back box contains 8 combination / knockouts. The door mounts with 2 locknuts and the back plate with 4 locknuts. The enclosure includes a key lock.

    FIG U R E 1 C BC M O U N TIN G D IM EN SIO N S

    4 3/16"

    15 9/64"

    5 25 /64 "

    17 1/2 "

    8 3/4"

    2 3/16"

    2 "

    4 5/16" 8 5/8 " 4 5 /16 "

    2 "

    4 3/16"

    17 1/2 "

    5 /8"