Adsorption Chiller Aggregates eCoo 2.0 ǀ eZea Energy efficient heating and cooling with Supro
Advantages at a glance
Up to 90% reduction in power requirements in comparison tot electrical chiller units.
Reliable dimensioning, simple assembly and flexible operation.
Variable control technology ensures maximum energy efficiency.
Idea usage in combination with CHPs industrial heat, solar thermal plants and district heating
Interconnection of several aggregates
Operation as heat pump to support heating activities.
Reduction of CO2 emission.
Clean technology, environmentally friendly substances such as silica gel and zeolite.
Water as the refrigerant
No refrigeration technician’s license required.
Key characteristics
Type / application range eCoo 2.0 eZea Hot water temperature (HT) 50 – 95 °C 75 – 95 °C
Recooling water temperature (MT) 22 – 40 °C 22 – 45 °C
Chilled water temperature (LT) 8 – 21 °C 8 – 21 °C
Dimensions W x D x H (mm) 800 x 620 x 1732 670 x 560 x 1652
Type / application range eCoo 2.0 eZea Refrigeration Power Up to 16 kW Up to 13 kW
Heating capacity Up to 50 kW Up to 40 kW
COP therm. Max. 0,65 Max. 0,53
Adsorption Chiller Aggregate eCoo 2.0 ǀ 10 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 10 IPS (KL10000009)
Weigh Empty weight Ca. 357 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 1,6 – 2,5 m3/h
Pressure drop 120 – 280 mbar
Max. additional delivery height 725 – 464 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread 1¼ “ AG
Heat rejection circuit / Heating water circuit (MT) Volume flow 4,1 – 5,1 m3/h
Pressure drop 275 – 420 mbar
Max. additional delivery height 925 – 690 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread 1½ “ AG
Chilled water circuit (LT) Volume flow 2,0 – 2,9 m3/h
Pressure drop 280 – 570 mbar
Max. additional delivery height 920 – 630 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread 1¼ “ AG
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 16 kW
Heating power Up to 50 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 800 x 620 x 1732
Floor space required 0,5 m2
Power drawn / power connection Power drawn without pump group 6 W (Ø)
At pressure loss eCoo 2.0 120 – 260 W
At claiming the max. delivery height 618 – 684 W
Power supply 230 V, 50/60 Hz
Cascading connections eCoo 2.0 – For more refrigeration power!
Energy efficient cooling and heating with Supro Cooling
Interconnection kit for the hydraulic connection of several eCoo 2.0 adsorption chiller aggregates tot
scale performace and tot simplify system integration.
Assembly consoles inclusive fittings to mount afdsorption chiller aggregates and tot attach connection
pipes.
Ready-made labeled and insolated flexible hoses tot attach the connetion pipes tot the adsorption chiller
aggregates eCoo 2.0.
Sumple connectivity of flexible hoses.
Includes safty groups and fill valves.
Start-up / cut-off via potential-free contact (e.g. in connetion with builing control system (GLT), external
controls, thermostat).
Various recooler solutions available
Customer specific design possible (e.g. speed-controlled pumps etc.).
Cascading connections with up to eight eCoo 2.0 aggregates
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 20 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 20 IPS (KL10000010)
Weigh Empty weight Ca. 755 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 3,2 – 5,0 m3/h
Max. additional delivery height 690 – 400 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Heat rejection circuit / Heating water circuit (MT) Volume flow 8,2 – 10,2 m3/h
Max. additional delivery height 890 – 640 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Chilled water circuit (LT) Volume flow 4,0 – 5,8 m3/h
Max. additional delivery height 860 – 520 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 32 kW
Heating power Up to 100 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 800 x 1338 x 2345
Floor space required 1,07 m2
Power drawn / power connection At pressure loss eCoo 2.0 240 – 520 W
At claiming the max. delivery height 1236 – 1368 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 30 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 30 IPS (KL10000011)
Weigh Empty weight Ca. 1160 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 4,8 – 7,5 m3/h
Max. additional delivery height 680 – 360 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40 rechte pijp
Heat rejection circuit / Heating water circuit (MT) Volume flow 12,3 – 15,3 m3/h
Max. additional delivery height 890 – 640 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65 rechte pijp
Chilled water circuit (LT) Volume flow 6,0 – 8,7 m3/h
Max. additional delivery height 860 – 520 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50 rechte pijp
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 48 kW
Heating power Up to 160 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 1700 x 1338 x 2386
Floor space required 2,27 m2
Power drawn / power connection At pressure loss eCoo 2.0 360 – 780 W
At claiming the max. delivery height 1854 – 2052 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 40 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 40 IPS (KL10000012)
Weigh Empty weight Ca. 1520 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 6,4 – 10,0 m3/h
Max. additional delivery height 660 – 320 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Heat rejection circuit / Heating water circuit (MT) Volume flow 16,4 – 20,4 m3/h
Max. additional delivery height 880 – 620 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Chilled water circuit (LT) Volume flow 8,0 – 11,6 m3/h
Max. additional delivery height 850 – 500 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 64 kW
Heating power Up to 200 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 1700 x 1338 x 2386
Floor space required 2,27 m2
Power drawn / power connection At pressure loss eCoo 2.0 480 – 1040 W
At claiming the max. delivery height 2472 – 2736 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 50 IPS
Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 50 IPS (KL10000013)
Weigh Empty weight Ca. 1940 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 8,0 – 12,5 m3/h
Max. additional delivery height 680 – 350 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 20,5 – 25,5 m3/h
Max. additional delivery height 880 – 620 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 10,0 – 14,5 m3/h
Max. additional delivery height 860 – 520 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 80 kW
Heating power Up to 250 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 2600 x 1338 x 2396
Floor space required 3,48 m2
Power drawn / power connection At pressure loss eCoo 2.0 600 – 1300 W
At claiming the max. delivery height 3090 – 3420 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 60 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 60 IPS (KL10000014)
Weigh Empty weight Ca. 2290 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 9,6 – 15,0 m3/h
Max. additional delivery height 660 – 320 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 24,6 – 30,6 m3/h
Max. additional delivery height 870 – 600 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 12,0 – 17,4 m3/h
Max. additional delivery height 860 – 500 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 96 kW
Heating power Up to 300 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 2600 x 1338 x 2396
Floor space required 3,48 m2
Power drawn / power connection At pressure loss eCoo 2.0 720 – 1560 W
At claiming the max. delivery height 3708 – 4104 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 70 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 70 IPS (KL10000015)
Weigh Empty weight Ca. 2690 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 11,2 – 17,5 m3/h
Max. additional delivery height 640 – 270 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 28,7 – 35,7 m3/h
Max. additional delivery height 850 – 570 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 14,0 – 20,3 m3/h
Max. additional delivery height 850 – 480 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 112 kW
Heating power Up to 350 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 3500 x 1338 x 2396
Floor space required 4,68 m2
Power drawn / power connection At pressure loss eCoo 2.0 840 – 1820 W
At claiming the max. delivery height 4326 – 4788 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo 2.0 ǀ 80 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo 2.0 ǀ 80 IPS (KL10000016)
Weigh Empty weight Ca. 3050 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 12,8 – 20,0 m3/h
Max. additional delivery height 620 – 230 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 32,8 – 40,8 m3/h
Max. additional delivery height 830 – 550 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 16,0 – 23,2 m3/h
Max. additional delivery height 840 – 460 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 40 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 128 kW
Heating power Up to 400 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 3500 x 1338 x 2396
Floor space required 4,68 m2
Power drawn / power connection At pressure loss eCoo 2.0 960 – 2080 W
At claiming the max. delivery height 4944 – 5472 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate eZea ǀ 10 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 10 IPS (KL10000017)
Weigh Empty weight Ca. 234,5 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 1,6 – 2,5 m3/h
Pressure drop 246 – 579 mbar
Max. additional delivery height 954 – 621 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread 1¼ “ AG
Heat rejection circuit / Heating water circuit (MT) Volume flow 4,1 – 5,1 m3/h
Pressure drop 380 – 570 mbar
Max. additional delivery height 820 – 540 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread 1½ “ AG
Chilled water circuit (LT) Volume flow 2,0 – 2,9 m3/h
Pressure drop 290 – 615 mbar
Max. additional delivery height 910 – 585 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread 1¼ “ AG
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 13 kW
Heating power Up to 40 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 670 x 560 x 1652
Floor space required 0,38 m2
Power drawn / power connection Power drawn without pump group 6 W (Ø)
At pressure loss eCoo 2.0 147 – 357 W
At claiming the max. delivery height 618 – 648 W
Power supply 230 V, 50/60 Hz
Cascading connections eZea – For more refrigeration power!
Energy efficient cooling and heating with Supro Cooling
Interconnection kit for the hydraulic connection of several eZea adsorption chiller aggregates tot scale
performace and tot simplify system integration.
Assembly consoles inclusive fittings to mount afdsorption chiller aggregates and tot attach connection
pipes.
Ready-made labeled and insolated flexible hoses tot attach the connetion pipes tot the adsorption chiller
aggregates eZea.
Sumple connectivity of flexible hoses.
Includes safty groups and fill valves.
Start-up / cut-off via potential-free contact (e.g. in connetion with builing control system (GLT), external
controls, thermostat).
Various recooler solutions available
Customer specific design possible (e.g. speed-controlled pumps etc.).
Cascading connections with up to eight eZea aggregates
Adsorption Chiller Aggregate Cascading eZea ǀ 20 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 20 IPS (KL10000018)
Weigh Empty weight Ca. 510 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 3,2 – 5,0 m3/h
Max. additional delivery height 920 – 560 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Heat rejection circuit / Heating water circuit (MT) Volume flow 8,2 – 10,2 m3/h
Max. additional delivery height 780 – 490 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Chilled water circuit (LT) Volume flow 4,0 – 5,8 m3/h
Max. additional delivery height 860 – 480 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 26 kW
Heating power Up to 80 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 670 x 1216 x 2265
Floor space required 0,81 m2
Power drawn / power connection At pressure loss eZea 294 – 714 W
At claiming the max. delivery height 1436 – 1584 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eZea ǀ 30 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 30 IPS (KL10000019)
Weigh Empty weight Ca. 790 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 4,8 – 7,5 m3/h
Max. additional delivery height 910 – 520 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Heat rejection circuit / Heating water circuit (MT) Volume flow 12,3 – 15,3 m3/h
Max. additional delivery height 780 – 490 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Chilled water circuit (LT) Volume flow 6,0 – 8,7 m3/h
Max. additional delivery height 860 – 480 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 39 kW
Heating power Up to 120 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 1440 x 1216 x 2306
Floor space required 1,75 m2
Power drawn / power connection At pressure loss eZea 441 – 1071 W
At claiming the max. delivery height 2154 – 2376 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eZea ǀ 40 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 40 IPS (KL10000020)
Weigh Empty weight Ca. 1025 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 6,4 – 10,0 m3/h
Max. additional delivery height 900 – 490 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN40
Heat rejection circuit / Heating water circuit (MT) Volume flow 16,4 – 20,4 m3/h
Max. additional delivery height 770 – 470 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Chilled water circuit (LT) Volume flow 8,0 – 11,6 m3/h
Max. additional delivery height 850 – 460 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 52 kW
Heating power Up to 160 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 1440 x 1216 x 2306
Floor space required 1,75 m2
Power drawn / power connection At pressure loss eZea 588 – 1428 W
At claiming the max. delivery height 2872 – 3168 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eZea ǀ 50 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 50 IPS (KL10000021)
Weigh Empty weight Ca. 1310 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 8,0 – 12,5 m3/h
Max. additional delivery height 910 – 510 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 20,5 – 25,5 m3/h
Max. additional delivery height 770 – 470 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 10,0 – 14,5 m3/h
Max. additional delivery height 850 – 470 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 65 kW
Heating power Up to 200 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 2210 x 1216 x 2316
Floor space required 2,69 m2
Power drawn / power connection At pressure loss eZea 735 – 1785 W
At claiming the max. delivery height 3590 – 3960 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eZea ǀ 60 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 60 IPS (KL10000022)
Weigh Empty weight Ca. 1545 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 9,6 – 15,0 m3/h
Max. additional delivery height 900 – 490 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 24,6 – 30,6 m3/h
Max. additional delivery height 760 – 460 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 12,0 – 17,4 m3/h
Max. additional delivery height 850 – 460 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 78 kW
Heating power Up to 240 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 2210 x 1216 x 2316
Floor space required 2,69 m2
Power drawn / power connection At pressure loss eZea 882 – 2142 W
At claiming the max. delivery height 4308 – 4752 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eZea ǀ 70 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 70 IPS (KL10000023)
Weigh Empty weight Ca. 1820 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 11,2 – 17,5 m3/h
Max. additional delivery height 880 – 440 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 28,7 – 35,7 m3/h
Max. additional delivery height 750 – 430 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 14,0 – 20,3 m3/h
Max. additional delivery height 840 – 440 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 91 kW
Heating power Up to 280 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 2980 x 1216 x 2316
Floor space required 3,62 m2
Power drawn / power connection At pressure loss eZea 1029 – 2499 W
At claiming the max. delivery height 5026 – 5544 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eZea ǀ 80 IPS Energy efficient cooling and heating with Supro Cooling
Application & performance data eZea ǀ 80 IPS (KL10000024)
Weigh Empty weight Ca. 2055 kg* *With pump group and casing
Hot water circuit (HT) Volume flow 12,8 – 20,0 m3/h
Max. additional delivery height 860 – 400 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN50
Heat rejection circuit / Heating water circuit (MT) Volume flow 32,8 – 40,8 m3/h
Max. additional delivery height 730 – 400 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN80
Chilled water circuit (LT) Volume flow 16,0 – 23,2 m3/h
Max. additional delivery height 830 – 420 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread DN65
Application range Hot water temperature (HT) 75 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 104 kW
Heating power Up to 320 kW
COP therm. Max. 0,53
Dimensions W x D x H (mm) 2980 x 1216 x 2316
Floor space required 3,62 m2
Power drawn / power connection At pressure loss eZea 1176 – 2856 W
At claiming the max. delivery height 5744 – 6336 W
Power supply 230 V, 50/60 Hz
Adsorption Chiller Aggregate Cascading eCoo Industry Energy efficient cooling and heating with Supro Cooling
More eCoo for higher performance
Flexible
Compact
Various heat sources: The new eCoo Industry is perfectly adapted to the needs of the industry. Whether CHP heat, process heat (e.g. from air compressors of servers), solar thermal energy of district hetating – eCoo Industry can be configured individually with almost any type of heat source SIEMENS control technology: The modern control technology from Simens considerably simplifies the operation of the refrigeration system since it can be combined easily with all interfaces in the facility management.
All in one housing: For the first time, sevaral adsorption chillers were installed in one houding. This not only creates a space saving of 50%, but also simplifies the installation considerably furthermore. Higher protection class: The new housing ensures the realization fo the higher protection class IP 54 Integrated system separation: The integrated system saparation is an additional advantage thus eliminating installation and piping work with the installation of the chillers
Robust
Ideal for the industry: Through the entegration of all system components in one housing, eCoo Industry is adapted to the specific requirements of the industrial environments.
Proven components: Furthermore, for years alle components used were installed in Supro adsorption chillers and continuously optimised. This makes eCoo Industry an especially durable, low-mantenance refrigeration plant.
Adsorption Chiller Aggregate Cascading eCoo Industry Energy efficient cooling and heating with Supro Cooling
Application & performance data eCoo Industry
Weigh Empty weight Ca. 1330 kg* *With pump group, system separation and casing
Hot water circuit (HT) Volume flow 4,8 – 7,5 m3/h
Max. additional delivery height 870 – 840 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread G 2” IG
Heat rejection circuit / Heating water circuit (MT) Volume flow 14,4 – 17,7 m3/h
Max. additional delivery height 830 – 700 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread G 2”IG
Chilled water circuit (LT) Volume flow 6,0 – 8,7 m3/h
Max. additional delivery height 840 – 410 mbar
Max. operating pressure 4 bar
Hydraulic connection – external thread G 2” IG
Application range Hot water temperature (HT) 50 – 95 °C
Recooling water temperature (MT) 22 – 45 °C
Chille water temperatuur (LT) 8 – 21 °C
Hot water temperature (free heating) 25 – 70 °C
Free cooling Ø ∆T 3K
Basic performace data Refrigeration power Up to 48 kW
Heating power Up to 150 kW
COP therm. Max. 0,65
Dimensions W x D x H (mm) 874 x 1864 x 2004
Floor space required 1,63 m2
Power drawn / power connection At pressure loss eCoo 2.0 645 – 1090 W
At claiming the max. delivery height 1924 – 2140 W
Power supply 230 V, 50/60 Hz
Cooling with adsorption and compression
Always operating at the right capacity – Always at the right time
The HybridChiller provides the
right refrigeration alt all times
for all load scenarios. According
tot the cooling requirements and
available heat, the intelligent
control system decides whether
to use compression and
adsorption in monovalent ofr
bivalent mode depending on the
situation. So even the effect of
peak loads can be cushioned
with extreme precision and
without delay. The control
system ensures the unit
operates at maximum efficiency
at all times.
EFFICIENT
EASY EXACT
Even the HybridChiller uses excess heat as a drive source. This makes our cooling more cost efficient than other cooling technologies. In addition, the combination of compression and adsorption is 5.5 times more efficient than the sole cooling with compression.
The HybridChiller, combines all mentioned advantages in just one machine, and is particularly quick to install. In addition, the HybridChiller manifests itself through a low-maintenance and flexibly useable technology.
By balancing the compression refrigeration, fluctuating ambient and load temperatures can be compensated. This ensures a particularly exact cooling temperature.
Adsorption HybridChiller Energy efficient cooling with Supro Cooling
Technische specificaties HybridChiller (KL10000008)
Cold water circuit (LT) Temperature range 8 – 21 °C
Max. Refrigeration power 49,6 kW
Volume flow 7,4 m3/h
Available delivery height 717 mbar
Connections inlet / outlet 1½ “ Rp
Hot water circuit (HT) Temperature range 50 – 95 °C
Max. thermal output 32,3 kW
Volume flow 2,5 m3/h
Available delivery height 350 mbar
Connections inlet / outlet 1¼ “ Rp
Re-cooling circuit (MT) water / glykol Temperature range 22 – 40 °C
Volumestroom 5,1 m3/h
Available delivery height 283 mbar
Connections inlet / outlet 1½ “ Rp
Basic date Dimensions W x D x H (mm) 874 x 1505 x 2004
Transport dimensions W x D x H (mm)
924 x 1555 x 2154
Weight 840 kg
Sound pressure level in 5 m (50/60 Hz)
59/62 dB(A)
Elektrische Connection Supply voltage 230 V, 50/60 Hz
Max. power consumption 15,76 kW
Max. current 30 A
Compression cooling Compressor Scroll / 1 x
Refrigeration power 32 kW
At a temperature of +35°C
Refrigerant R407C or R134A & R718 (H2O)
Seasonal performance data
ESEER (total) 19,64
ESEER (Partial load 100%)** 4,31 with power consumption of 6,04 kW
ESEER (Partial load 75%) 6,52 with power consumption of 2,99 kW
ESEER (Partial load 50%) 27,2 with power consumption of 0,48 kW
ESEER (Partial load 25%) 30,81 with power consumption of 0,21 kW
*ESEER with input temperatures: 85 °C hot water temp. & 19 °C cold water temp. **100% corresponds to 26 kW cooling capacity
Supro Recoolers Integrated electricity-saving EC technology & system for temperature-controlled and infinitely variable control of
the fan speed
For optimal effeciency of the Supro adsorption chillers a recooler is required. For optimal operation of the total
adsorption cooling system, Supro selected a line of very quiet and energy efficient eRec and eRis Recoolers.
System integration of the recooler is very simple with a prefabricated system separation.
Recooler eRec ǀ efficiency Recooler
Supro Recooler with spray system
Recooler eRis ǀ efficiency Recooler internationaal systeem
Supro Recooler
Recooler Optimised for type eCoo 2.0 & eZea ǀ 10 – 80 IPS
Horizontal installation with fork or lift
High efficiency Recooler
By coating aluminium fins there is no upgrade possible with a spray system
Recooler with spray system Optimised for type eCoo 2.0 & eZea ǀ 10 – 40 IPS koelmachines
Vertical installation with fork of lift
Spray medium water
Spray system include: spray lance, pressure reducer, solenoid valve and drain valve
Temporary spray of the vins via spray lance to cover preak loads
Recooler Optimised for type eCoo 2.0 & eZea ǀ 10 – 80 IPS
Horizontal installation with fork or lift
By coating aluminium fins there is no upgrade possible with a spray system
Recooler with spray system Optimised for type eCoo 2.0 & eZea ǀ 10 – 40 IPS koelmachines
Vertical installation with fork of lift
Spray medium water
Spray system include: spray lance, pressure reducer, solenoid valve and drain valve
Temporary spray of the vins via spray lance to cover preak loads
Recooler eRec ǀ A++ * Optimised for the eCoo 2.0 & eZea ǀ 10 IPS adsorption Chiller
Technical data eRec 10 ǀ 29 (KL10000025) Technical data eRec 10 ǀ 40 (KL10000026)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 29 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,7 / 26,4 °C
Air flow 24000 m3/h
Pressure loss at nominal volume flow 290 mbar
Ventilators Ventilators 2 x EC ventilatoren
Sound pressure level in 10 m 34 dB(A)
Weight Unladen weight Ca. 438 kg
Tubing content 46,1 l
Dimensions W x D x H (mm) 4230 x 1170 x 1510
Floor space required 4,95 m2
Power drawn / power connection Power drawn 0,54 kW
Power supply 230 V, 50/60 Hz
Performacen data Recooler capacity Tot 40 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 26,3 °C
Air flow 36000 m3/h
Pressure loss at nominal volume flow 220 mbar
Ventilators Ventilators EC ventilatoren /
3 stuks
Sound pressure level in 10 m 36 dB(A)
Weight Unladen weight Ca. 612 kg
Tubing content
Dimensions W x D x H (mm) 6130 x 1170 x 1510
Floor space required 7,17 m2
Power drawn / power connection Power drawn 0,72 kW
Power supply 230 V, 50 Hz
Recooler eRec ǀ A++ * Optimised for the eCoo 2.0 & eZea ǀ 20 IPS Chiller cascade
Technical data eRec 20 ǀ 58 (KL10000027) Technical data eRec 20 ǀ 80 (KL10000028)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 58 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,7 / 26,4 °C
Air flow 47000 m3/h
Pressure loss at nominal volume flow 280 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 37 dB(A)
Weight Unladen weight Ca. 791 kg
Tubing content 94,7 l
Dimensions W x D x H (mm) 4230 x 2290 x 1510
Floor space required 9,69 m2
Power drawn / power connection Power drawn 1,08 kW
Power supply 230 V, 50/60 Hz
Performacen data Recooler capacity Up to 80 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 28,1 °C
Air flow 47000 m3/h
Pressure loss at nominal volume flow 230 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 37 dB(A)
Weight Unladen weight Ca. 841 kg
Tubing content 86,5 l
Dimensions W x D x H (mm) 5030 x 2290 x 1510
Floor space required 11,52 m2
Power drawn / power connection Power drawn 1,0 kW
Power supply 230 V, 50 Hz
Recooler eRec ǀ A+ * Optimised for the eCoo 2.0 & eZea ǀ 30 IPS Chiller cascade
Technical data eRec 30 ǀ 87 (KL10000029) Technical data eRec 30 ǀ 120 (KL10000030)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 87 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,6 / 25,9 °C
Air flow 78000 m3/h
Pressure loss at nominal volume flow 230 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 43 dB(A)
Weight Unladen weight Ca. 1095 kg
Tubing content 120,3 l
Dimensions W x D x H (mm) 5230 x 2290 x 1510
Floor space required 11,98 m2
Power drawn / power connection Power drawn 2,4 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 120 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 27,2 °C
Air flow 86000 m3/h
Pressure loss at nominal volume flow 180 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1150 kg
Tubing content 178,3 l
Dimensions W x D x H (mm) 6130 x 2290 x 1510
Floor space required 14,04 m2
Power drawn / power connection Power drawn 3,06 kW
Power supply 400V, 50 Hz
Recooler eRec ǀ A+ * Optimised for the eCoo 2.0 & eZea ǀ 40 IPS Chiller cascade
Technical data eRec 40 ǀ 116 (KL10000031) Technical data eRec 40 ǀ 160 (KL10000032)
Individual selection of the Recooling system or help with system integration is possible on request.
*Energie efficiëntie klasse, berekend op basis van de Eurovent normering
Performacen data Recooler capacity Up to 116 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,6 / 26,5 °C
Air flow 89000 m3/h
Pressure loss at nominal volume flow 300 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1166 kg
Tubing content 178,3 l
Dimensions W x D x H (mm) 6130 x 2290 x 1510
Floor space required 14,04 m2
Power drawn / power connection Power drawn 3,24 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 160 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 27,4 °C
Air flow 110000 m3/h
Pressure loss at nominal volume flow 180 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1760 kg
Tubing content 403,7 l
Dimensions W x D x H (mm) 9630 x 2290 x 1510
Floor space required 22,05 m2
Power drawn / power connection Power drawn 3,2 kW
Power supply 400V, 50 Hz
Recooler eRec ǀ A+ * Optimised for the eCoo 2.0 & eZea ǀ 50 IPS Chiller cascade
Technical data eRec 50 ǀ 145 (KL10000033) Technical data eRec 50 ǀ 200 (KL10000034)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 145 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 29,5 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,7 / 27,0 °C
Air flow 102000 m3/h
Pressure loss at nominal volume flow 490 mbar
Ventilators Ventilators 8 x EC ventilatoren
Sound pressure level in 10 m 47 dB(A)
Weight Unladen weight Ca. 1565 kg
Tubing content 199,9 l
Dimensions W x D x H (mm) 6830 x 2290 x 1510
Floor space required 15,64 m2
Power drawn / power connection Power drawn 4,08 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 200 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 29,5 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 27,2 °C
Air flow 144000 m3/h
Pressure loss at nominal volume flow 270 mbar
Ventilators Ventilators 10 x EC ventilatoren
Sound pressure level in 10 m 47 dB(A)
Weight Unladen weight Ca. 1880 kg
Tubing content 416,8 l
Dimensions W x D x H (mm) 9630 x 2290 x 1510
Floor space required 22,05 m2
Power drawn / power connection Power drawn 5,5 kW
Power supply 400V, 50 Hz
Recooler eRec ǀ A+ * Optimised for the eCoo 2.0 & eZea ǀ 60 IPS Chiller cascade
Technical data eRec 60 ǀ 174 (KL10000035) Technical data eRec 60 ǀ 240 (KL10000036)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 174 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 35,4 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,9 / 26,6 °C
Air flow 145000 m3/h
Pressure loss at nominal volume flow 450 mbar
Ventilators Ventilators 10 x EC ventilatoren
Sound pressure level in 10 m 47 dB(A)
Weight Unladen weight Ca. 1953 kg
Tubing content 232,3 l
Dimensions W x D x H (mm) 9930 x 2290 x 1510
Floor space required 22,74 m2
Power drawn / power connection Power drawn 4,9 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 240 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 35,4 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 26,9 °C
Air flow 183000 m3/h
Pressure loss at nominal volume flow 260 mbar
Ventilators Ventilators 12 x EC ventilatoren
Sound pressure level in 10 m 46 dB(A)
Weight Unladen weight Ca. 2240 kg
Tubing content 283,7 l
Dimensions W x D x H (mm) 11830 x 2290 x 1510
Floor space required 27,09 m2
Power drawn / power connection Power drawn 6,36 kW
Power supply 400V, 50 Hz
Recooler eRec ǀ A+ * Optimised for the eCoo 2.0 & eZea ǀ 70 IPS Chiller cascade
Technical data eRec 70 ǀ 203 (KL10000037) Technical data eRec 70 ǀ 280 (KL10000038)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 203 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 41,3 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,8 / 26,6 °C
Air flow 160000 m3/h
Pressure loss at nominal volume flow 340 mbar
Ventilators Ventilators 10 x EC ventilatoren
Sound pressure level in 10 m 47 dB(A)
Weight Unladen weight Ca. 2249 kg
Tubing content 286,1 l
Dimensions W x D x H (mm) 11930 x 2290 x 1510
Floor space required 27,32 m2
Power drawn / power connection Power drawn 5,1 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 280 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 41,3 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 27,6 °C
Air flow 185000 m3/h
Pressure loss at nominal volume flow 260 mbar
Ventilators Ventilators 10 x EC ventilatoren
Sound pressure level in 10 m 48 dB(A)
Weight Unladen weight Ca. 2127 kg
Tubing content 348,4 l
Dimensions W x D x H (mm) 11630 x 2290 x 1510
Floor space required 26,63 m2
Power drawn / power connection Power drawn 7,98 kW
Power supply 400V, 50 Hz
Recooler eRec ǀ A+ * Optimised for the eCoo 2.0 & eZea ǀ 80 IPS Chiller cascade
Technical data eRec 80 ǀ 232 (KL10000039) Technical data eRec 80 ǀ 320 (KL10000040)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 232 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 47,2 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 22,6 / 26,4 °C
Air flow 183000 m3/h
Pressure loss at nominal volume flow 430 mbar
Ventilators Ventilators 12 x EC ventilatoren
Sound pressure level in 10 m 48 dB(A)
Weight Unladen weight Ca. 2318 kg
Tubing content 283,7 l
Dimensions W x D x H (mm) 11830 x 2290 x 1510
Floor space required 27,09 m2
Power drawn / power connection Power drawn 6,36 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 320 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 47,2 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 23,0 / 26,8 °C
Air flow 252000 m3/h
Pressure loss at nominal volume flow 170 mbar
Ventilators Ventilators 16 x EC ventilatoren
Sound pressure level in 10 m 49 dB(A)
Weight Unladen weight Ca. 3260 kg
Tubing content 416,1 l
Dimensions W x D x H (mm) 10095 x 2370 x 2300
Floor space required 23,93 m2
Power drawn / power connection Power drawn 9,12 kW
Power supply 400V, 50 Hz
Recooler eRec ǀ A++ * with spray system Optimised for the eCoo 2.0 & eZea ǀ 10 IPS Chiller
Technical data eRec 10 ǀ 29 wet Technical data eRec 10 ǀ 40 wet
(KL10000041) (KL10000042)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 29 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Water consumption Max. 6 m3 per jaar
Temperature air inlet / outlet 22,7 / 26,4 °C
Air flow 24000 m3/h
Pressure loss at nominal volume flow 290 mbar
Ventilators Ventilators 2 x EC ventilatoren
Sound pressure level in 10 m 34 dB(A)
Weight Unladen weight Ca. 438 kg
Tubing content 46,1 l
Dimensions W x D x H (mm) 4230 x 1050 x 1260
Floor space required 4,23 m2
Power drawn / power connection Power drawn 0,54 kW
Power supply 230 V, 50/60 Hz
Performacen data Recooler capacity Up to 40 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Water consumption Max. 6 m3 per jaar
Temperature air inlet / outlet 23,0 / 26,2 °C
Air flow 37000 m3/h
Pressure loss at nominal volume flow 220 mbar
Ventilators Ventilators 2 x EC ventilatoren
Sound pressure level in 10 m 36 dB(A)
Weight Unladen weight Ca. 612 kg
Tubing content 53,5 l
Dimensions W x D x H (mm) 6130 x 1050 x 1260
Floor space required 6,44 m2
Power drawn / power connection Power drawn 0,78 kW
Power supply 230 V, 50 Hz
Recooler eRec ǀ A++ * with spray system Optimised for the eCoo 2.0 & eZea ǀ 20 IPS Chiller cascade
Technical data eRec 20 ǀ 58 wet Technical data eRec 20 ǀ 80 wet
(KL10000043) (KL10000044)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 58 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Water consumption Max. 9 m3 per jaar
Temperature air inlet / outlet 22,7 / 26,4 °C
Air flow 48000 m3/h
Pressure loss at nominal volume flow 280 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 37 dB(A)
Weight Unladen weight Ca. 791 kg
Tubing content 94,7 l
Dimensions W x D x H (mm) 4230 x 1050 x 2380
Floor space required 4,23 m2
Power drawn / power connection
Power drawn 1,08 kW
Power supply 230 V, 50/60 Hz
Performacen data Recooler capacity Up to 80 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Water consumption Max. 9 m3 per jaar
Temperature air inlet / outlet 23,0 / 28,0 °C
Air flow 48000 m3/h
Pressure loss at nominal volume flow 230 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 37 dB(A)
Weight Unladen weight Ca. 841 kg
Tubing content 86,5 l
Dimensions W x D x H (mm) 5030 x 1050 x 2380
Floor space required 5,28 m2
Power drawn / power connection
Power drawn 1,04 kW
Power supply 230 V, 50 Hz
Recooler eRec ǀ A++ * with spray system Optimised for the eCoo 2.0 & eZea ǀ 30 IPS Chiller cascade
Technical data eRec 30 ǀ 87 wet Technical data eRec 30 ǀ 120 wet
(KL10000045) (KL10000046)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 87 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Water consumption Max. 12 m3 per jaar
Temperature air inlet / outlet 22,6 / 25,9 °C
Air flow 80000 m3/h
Pressure loss at nominal volume flow 230 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 43 dB(A)
Weight Unladen weight Ca. 1095 kg
Tubing content 120,3 l
Dimensions W x D x H (mm) 5230 x 1050 x 2380
Floor space required 5,43 m2
Power drawn / power connection Power drawn 2,52 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 120 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Water consumption Max. 12 m3 per jaar
Temperature air inlet / outlet 23,0 / 27,1 °C
Air flow 89000 m3/h
Pressure loss at nominal volume flow 180 mbar
Ventilators Ventilators 6 x EC ventilatorens
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1150 kg
Tubing content 178,3 l
Dimensions W x D x H (mm) 6130 x 1050 x 2380
Floor space required 6,43 m2
Power drawn / power connection Power drawn 3,24 kW
Power supply 400 V, 50 Hz
Recooler eRec ǀ A++ * with spray system Optimised for the eCoo 2.0 & eZea ǀ 40 IPS Chiller cascade
Technical data eRec 40 ǀ 116 wet Technical data eRec 40 ǀ 160 wet
(KL10000047) (KL10000048)
Individual selection of the Recooling system or help with system integration is possible on request.
* Energy efficiency class, calculated on the basis of the Eurovent standards
Performacen data Recooler capacity Up to 116 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Water consumption Max. 15 m3 per jaar
Temperature air inlet / outlet 22,6 / 26,5 °C
Air flow 88000 m3/h
Pressure loss at nominal volume flow 300 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1166 kg
Tubing content 178,3 l
Dimensions W x D x H (mm) 6130 x 1050 x 2380
Floor space required 6,13 m2
Power drawn / power connection Power drawn 3,24 kW
Power supply 400 V, 50/60 Hz
Performacen data Recooler capacity Up to 160 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Water consumption Max. 15 m3 per jaar
Temperature air inlet / outlet 23,0 / 27,2 °C
Air flow 115000 m3/h
Pressure loss at nominal volume flow 180 mbar
Ventilators Ventilators 8 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1760 kg
Tubing content 403,7 l
Dimensions W x D x H (mm) 9630 x 1050 x 2380
Floor space required 10,11 m2
Power drawn / power connection Power drawn 3,68 kW
Power supply 400 V, 50 Hz
Recooler eRis ǀ 10 IPS Optimised for the eCoo 2.0 & eZea ǀ 10 IPS Chiller
Technical data eRis 10 ǀ 29 (KL10000049) Technical data eRis 10 ǀ 40 (KL10000050)
eRis 10 ǀ 29
eRis 10 ǀ 40
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 29 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,1 / 27,2 °C
Air flow 14000 m3/h
Pressure loss at nominal volume flow 420 mbar
Ventilators Ventilators 1 x EC ventilatoren
Sound pressure level in 10 m 35 dB(A)
Weight Unladen weight Ca. 340 kg
Tubing content 39,1 l
Dimensions W x D x H (mm) 2330 x 1490 x 1510
Floor space required 3,47 m2
Power drawn / power connection Power drawn 0,41 kW
Power supply 230 V, 50 Hz
Performacen data Recooler capacity Up to 40 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 27,0 °C
Air flow 22000 m3/h
Pressure loss at nominal volume flow 250 mbar
Ventilators Ventilators 2 x EC ventilatoren
Sound pressure level in 10 m 35 dB(A)
Weight Unladen weight Ca. 440 kg
Tubing content 38,9 l
Dimensions W x D x H (mm) 3630 x 1170 x 1510
Floor space required 4,25 m2
Power drawn / power connection Power drawn 0,56 kW
Power supply 230 V, 50 Hz
Recooler eRis ǀ 20 IPS Optimised for the eCoo 2.0 & eZea ǀ 20 IPS Chiller cascade
Technical data eRis 20 ǀ 58 (KL10000051) Technical data eRis 20 ǀ 80 (KL10000052)
eRis 20 ǀ 58
eRis 20 ǀ 80
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 58 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,6 °C
Air flow 33000 m3/h
Pressure loss at nominal volume flow 370 mbar
Ventilators Ventilators 3 x EC ventilatoren
Sound pressure level in 10 m 37 dB(A)
Weight Unladen weight Ca. 620 kg
Tubing content 60,2 l
Dimensions W x D x H (mm) 5230 x 1170 x 1510
Floor space required 6,12 m2
Power drawn / power connection Power drawn 0,90 kW
Power supply 230 V, 50 Hz
Performacen data Recooler capacity Up to 80 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 27,0 °C
Air flow 44000 m3/h
Pressure loss at nominal volume flow 240 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 38 dB(A)
Weight Unladen weight Ca. 770 kg
Tubing content 80,6 l
Dimensions W x D x H (mm) 3630 x 2290 x 1510
Floor space required 8,31 m2
Power drawn / power connection Power drawn 1,12 kW
Power supply 230 V, 50 Hz
Recooler eRis ǀ 30 IPS Optimised for the eCoo 2.0 & eZea ǀ 30 IPS Chiller cascade
Technical data eRis 30 ǀ 87 (KL10000053) Technical data eRis 30 ǀ 120 (KL10000054)
eRis 30 ǀ 87
eRis 30 ǀ 120
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 87 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,3 / 25,8 °C
Air flow 58000 m3/h
Pressure loss at nominal volume flow 470 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 44 dB(A)
Weight Unladen weight Ca. 700 kg
Tubing content 80,1 l
Dimensions W x D x H (mm) 3630 x 2290 x 1510
Floor space required 8,31 m2
Power drawn / power connection
Power drawn 2,36 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 120 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,9 °C
Air flow 64000 m3/h
Pressure loss at nominal volume flow 220 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 44 dB(A)
Weight Unladen weight Ca. 1000 kg
Tubing content 115,4 l
Dimensions W x D x H (mm) 5030 x 2290 x 1510
Floor space required 11,52 m2
Power drawn / power connection
Power drawn 2,08 kW
Power supply 400 V, 50 Hz
Recooler eRis ǀ 40 IPS Optimised for the eCoo 2.0 & eZea ǀ 40 IPS Chiller cascade
Technical data eRis 40 ǀ 116 (KL10000055) Technical data eRis 40 ǀ 160 (KL10000056)
eRis 40 ǀ 116
eRis 40 ǀ 160
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 116 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,1 / 26,5 °C
Air flow 65000 m3/h
Pressure loss at nominal volume flow 360 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 44 dB(A)
Weight Unladen weight Ca. 1000 kg
Tubing content 90,3 l
Dimensions W x D x H (mm) 5030 x 2290 x 1510
Floor space required 11,52 m2
Power drawn / power connection Power drawn 2,04 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 160 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,5 °C
Air flow 96000 m3/h
Pressure loss at nominal volume flow 220 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1325 kg
Tubing content 227,6 l
Dimensions W x D x H (mm) 7330 x 2290 x 1510
Floor space required 16,79 m2
Power drawn / power connection Power drawn 3,12 kW
Power supply 400 V, 50 Hz
Recooler eRis ǀ 50 IPS Optimised for the eCoo 2.0 & eZea ǀ 50 IPS Chiller cascade
Technical data eRis 50 ǀ 145 (KL10000057) Technical data eRis 50 ǀ 200 (KL10000058)
eRis 50 ǀ 145
eRis 50 ǀ 200
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 145 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 29,5 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,2 / 26,5 °C
Air flow 82000 m3/h
Pressure loss at nominal volume flow 370 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 46 dB(A)
Weight Unladen weight Ca. 1067 kg
Tubing content 150,4 l
Dimensions W x D x H (mm) 5230 x 2290 x 1510
Floor space required 11,97 m2
Power drawn / power connection
Power drawn 3,66 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 200 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 29,5 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,0 °C
Air flow 134000 m3/h
Pressure loss at nominal volume flow 250 mbar
Ventilators Ventilators 8 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1630 kg
Tubing content 171,9 l
Dimensions W x D x H (mm) 9630 x 2290 x 1510
Floor space required 22,05 m2
Power drawn / power connection
Power drawn 4,32 kW
Power supply 400 V, 50 Hz
Recooler eRis ǀ 60 IPS Optimised for the eCoo 2.0 & eZea ǀ 60 IPS Chiller cascade
Technical data eRis 60 ǀ 174 (KL10000059) Technical data eRis 60 ǀ 240 (KL10000060)
eRis 60 ǀ 174
eRis 60 ǀ 240
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 174 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 29,6 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 25,5 °C
Air flow 130000 m3/h
Pressure loss at nominal volume flow 590 mbar
Ventilators Ventilators 8 x EC ventilatoren
Sound pressure level in 10 m 47 dB(A)
Weight Unladen weight Ca. 1388 kg
Tubing content 139,6 l
Dimensions W x D x H (mm) 8030 x 2290 x 1510
Floor space required 18,39 m2
Power drawn / power connection Power drawn 4,4 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 240 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 35,4 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 27,1 °C
Air flow 129000 m3/h
Pressure loss at nominal volume flow 210 mbar
Ventilators Ventilators 8 x EC ventilatoren
Sound pressure level in 10 m 46 dB(A)
Weight Unladen weight Ca. 1589 kg
Tubing content 229,2 l
Dimensions W x D x H (mm) 9630 x 2290 x 1510
Floor space required 22,05 m2
Power drawn / power connection Power drawn 4,16 kW
Power supply 400 V, 50 Hz
Recooler eRis ǀ 70 IPS Optimised for the 2.0 & eZea ǀ 70 IPS Chiller cascade
Technical data eRis 70 ǀ 203 (KL10000061) Technical data eRis 70 ǀ 280 (KL10000062)
eRis 70 ǀ 203
eRis 70 ǀ 280
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 203 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 41,3 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,5 °C
Air flow 122000 m3/h
Pressure loss at nominal volume flow 470 mbar
Ventilators Ventilators 8 x EC ventilatoren
Sound pressure level in 10 m 46 dB(A)
Weight Unladen weight Ca. 1632 kg
Tubing content 186,2 l
Dimensions W x D x H (mm) 8030 x 2290 x 1510
Floor space required 18,39 m2
Power drawn / power connection Power drawn 4,56 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 280 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 41,3 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,3 °C
Air flow 174000 m3/h
Pressure loss at nominal volume flow 290 mbar
Ventilators Ventilators 12 x EC ventilatoren
Sound pressure level in 10 m 48 dB(A)
Weight Unladen weight Ca. 1837 kg
Tubing content 179,3 l
Dimensions W x D x H (mm) 10030 x 2290 x 1510
Floor space required 22,97 m2
Power drawn / power connection Power drawn 6,6 kW
Power supply 400 V, 50 Hz
Recooler eRis ǀ 80 IPS Optimised for the eCoo 2.0 & eZea ǀ 80 IPS Chiller cascade
Technical data eRis 80 ǀ 232 (KL10000063) Technical data eRis 80 ǀ 320 (KL10000064)
eRis 80 ǀ 232
eRis 80 ǀ 320
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 232 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 47,2 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 26,0 °C
Air flow 155000 m3/h
Pressure loss at nominal volume flow 360 mbar
Ventilators Ventilators 10 x EC ventilatoren
Sound pressure level in 10 m 47 dB(A)
Weight Unladen weight Ca. 1725 kg
Tubing content 236,6 l
Dimensions W x D x H (mm) 9930 x 2290 x 1510
Floor space required 22,74 m2
Power drawn / power connection
Power drawn 5,70 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 320 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 47,2 m3/h
Max. operation pressure 4 bar
Temperature air inlet / outlet 21,5 / 27,5 °C
Air flow 159000 m3/h
Pressure loss at nominal volume flow 250 mbar
Ventilators Ventilators 12 x EC ventilatoren
Sound pressure level in 10 m 49 dB(A)
Weight Unladen weight Ca. 2339 kg
Tubing content 298,9 l
Dimensions W x D x H (mm) 10030 x 2290 x 1510
Floor space required 22,97 m2
Power drawn / power connection
Power drawn 6,96 kW
Power supply 400 V, 50 Hz
Recooler eRis with spray system Optimised for the eCoo 2.0 & eZea ǀ 10 IPS Chiller
Technical data eRis 10 ǀ 29 wet Technical data eRis 10 ǀ 40 wet
(KL10000065) (KL10000066)
eRis 10 ǀ 29 wet
eRis 10 ǀ 40 wet
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 29 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Water consumption Max. 6 m3 per jaar
Temperature air inlet / outlet 21,5 / 26,7 °C
Air flow 17000 m3/h
Pressure loss at nominal volume flow 290 mbar
Ventilators Ventilators 1 x EC ventilatoren
Sound pressure level in 10 m 37 dB(A)
Weight Unladen weight Ca. 355 kg
Tubing content 36,5 l
Dimensions W x D x H (mm) 2730 x 1050 x 1580
Floor space required 2,87 m2
Power drawn / power connection Power drawn 0,58 kW
Power supply 230 V, 50 Hz
Performacen data Recooler capacity Up to 40 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 5,9 m3/h
Max. operation pressure 4 bar
Water consumption Max. 6 m3 per jaar
Temperature air inlet / outlet 21,5 / 26,1 °C
Air flow 26000 m3/h
Pressure loss at nominal volume flow 210 mbar
Ventilators Ventilators 2 x EC ventilatoren
Sound pressure level in 10 m 36 dB(A)
Weight Unladen weight Ca. 425 kg
Tubing content 42,7 l
Dimensions W x D x H (mm) 5030 x 1050 x 1260
Floor space required 5,28 m2
Power drawn / power connection Power drawn 0,5 kW
Power supply 230 V, 50 Hz
Recooler eRis with spray system Optimised for the eCoo 2.0 & eZea ǀ 20 IPS Chiller cascade
Technical data eRis 20 ǀ 58 wet Technical data eRis 20 ǀ 80 wet
(KL10000067) (KL10000068)
eRis 20 ǀ 58 wet
eRis 20 ǀ 80 wet
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 58 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Water consumption Max. 9 m3 per jaar
Temperature air inlet / outlet 21,3 / 26,3 °C
Air flow 35000 m3/h
Pressure loss at nominal volume flow 440 mbar
Ventilators Ventilators 3 x EC ventilatoren
Sound pressure level in 10 m 36 dB(A)
Weight Unladen weight Ca. 630 kg
Tubing content 71,3 l
Dimensions W x D x H (mm) 6130 x 1050 x 1260
Floor space required 6,44 m2
Power drawn / power connection Power drawn 0,93 kW
Power supply 230 V, 50 Hz
Performacen data Recooler capacity Up to 80 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 11,8 m3/h
Max. operation pressure 4 bar
Water consumption Max. 9 m3 per jaar
Temperature air inlet / outlet 21,5 / 27,0 °C
Air flow 44000 m3/h
Pressure loss at nominal volume flow 280 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 36 dB(A)
Weight Unladen weight Ca. 771 kg
Tubing content 94,7 l
Dimensions W x D x H (mm) 4230 x 1050 x 2380
Floor space required 4,44 m2
Power drawn / power connection Power drawn 0,88 kW
Power supply 230 V, 50 Hz
Recooler eRis with spray system Optimised for the eCoo 2.0 & eZea ǀ 30 IPS koelmachines
Technical data eRis 30 ǀ 87 wet Technical data eRis 30 ǀ 120 wet
(KL10000069) (KL10000070)
eRis 30 ǀ 87 wet
eRis 30 ǀ 120 wet
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 87 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Water consumption Max. 12 m3 per jaar
Temperature air inlet / outlet 21,4 / 25,4 °C
Air flow 67000 m3/h
Pressure loss at nominal volume flow 360 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 841 kg
Tubing content 86,5 l
Dimensions W x D x H (mm) 5030 x 1050 x2380
Floor space required 5,28 m2
Power drawn / power connection Power drawn 1,96 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 120 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 17,7 m3/h
Max. operation pressure 4 bar
Water consumption Max. 12 m3 per jaar
Temperature air inlet / outlet 21,5 / 26,3 °C
Air flow 74000 m3/h
Pressure loss at nominal volume flow 230 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 43 dB(A)
Weight Unladen weight Ca. 980 kg
Tubing content 120,3 l
Dimensions W x D x H (mm) 5230 x 1050 x 2380
Floor space required 5,49 m2
Power drawn / power connection Power drawn 2,34 kW
Power supply 400 V, 50 Hz
Recooler eRis with spray system Optimised for the eCoo 2.0 & eZea ǀ 40 IPS Chiller cascade
Technical data eRis 430 ǀ 116 wet Technical data eRis 40 ǀ 160 wet
(KL10000071) (KL10000072)
eRis 40 ǀ 116 wet
eRis 40 ǀ 160 wet
Individual selection of the Recooling system or help with system integration is possible on request.
Performacen data Recooler capacity Up to 116 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 29,6 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Water consumption Max. 15 m3 per jaar
Temperature air inlet / outlet 21,1 / 26,6 °C
Air flow 63000 m3/h
Pressure loss at nominal volume flow 360 mbar
Ventilators Ventilators 4 x EC ventilatoren
Sound pressure level in 10 m 44 dB(A)
Weight Unladen weight Ca. 1030 kg
Tubing content 90,3 l
Dimensions W x D x H (mm) 5030 x 1050 x2380
Floor space required 5,28 m2
Power drawn / power connection Power drawn 2,12 kW
Power supply 400 V, 50 Hz
Performacen data Recooler capacity Up to 160 kW
Recooling medium Water / glycol 34 %
Water temperature inlet / outlet 31,3 / 25 °C
Nominal volume flow 23,6 m3/h
Max. operation pressure 4 bar
Water consumption Max. 15 m3 per jaar
Temperature air inlet / outlet 21,5 / 27,0 °C
Air flow 88000 m3/h
Pressure loss at nominal volume flow 140 mbar
Ventilators Ventilators 6 x EC ventilatoren
Sound pressure level in 10 m 45 dB(A)
Weight Unladen weight Ca. 1076 kg
Tubing content 303,5 l
Dimensions W x D x H (mm) 7330 x 1050 x 2380
Floor space required 7,70 m2
Power drawn / power connection Power drawn 2,82 kW
Power supply 400 V, 50 Hz
Supro system separation More than a plate heat exchanger.
For a simple hydraulic connection of an eCoo 2.0 or eZea chiller (cascade) with existing of newly pland recooling
system, drycooler, coolingtouwer or an other recooling systems ( for example, a swimming pool), there are
several system separations available. This makes system integration simple and rapid installation possible.
System separation ST-G-X*0 System separation ST-O-X*0 Systeem separation ST-B-X*0
System separation for a closed recooler / heat sink circuit (e.g. glycol operated closed recooler).
System separation for an open recooler / heat sink circuit (e.g. operation in combination with wet cooling tower).
System separation for an individual recooler / heat sink circuit (e.g. when uning a water/glycol mixture).
This system separation consists of: Mounting frame, one plate heat exchanger (tuned to the adsorption chiller (cascade), security groups, expansion tanks, one high effiency pump (glandless pump) that is optimised for the secundair recooling circuit.
This system separation consists of: Mounting frame, one plate heat exchanger (tuned to the adsorption chiller (cascade), one security groups, one expansion tanks, one high effiency pump (glandless pump) that is optimised for the secundair recooling circuit.
This system separation consists of: Mounting frame, one plate heat exchanger (tuned to the adsorption chiller (cascade), one security groups, one expansion tanks,
All system separations are tuned to the adsorption chiller or cascade. They profide an easy installation and connection of the recooling systemem.
*X = (1,2,3,4); 1 x system separation 10 corresponds to 1 x eCoo 2.0 10 IPS or 1 x eZea 10 IPS
Chose a left- or right-sided system deparation
For an effecient installation it is necessary to look carefully at the system integration and the placement of the
adsorption chiller (cascade), before selecting a left- or right-side system separation.
Afbeelding 1: left-side system separation ST-G-10 Afbeelding 2: right-side system separation ST-G-20
Supro system separation More than a plate heat exchanger.
System separation for closed recooler / System separation for open recooler /
heat sink circuit ST-G-10 (KL10000073) heat sink circuit ST-O-10 (KL10000074)
Article number Left-side system separation KL10000074-L Richt-side system separation KL10000074-R
General key performacen Type of fitting 1½”
Fitting dimensions DN40
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 5,1 m3/h
Pressure loss 180 mbar
Key performance towerds the recooler
Nominal volume flow rate 5,1 m3/h
Max. delivery height 680 mbar
Pressure loss 210 mbar
Weicht
Operational weight Ca. 150 kg
Demensions W x D x H (mm) 1138 x 749 x 1019
Oppervlakte opstelling 0,7 m2
Power drawn / Power connection Power drawn Max. 0,37 kW
Power supply 230 V, 50 Hz
Article number Left-side system separation KL1000007-L Richt-side system separation KL10000073-R
General key performance Type of fitting 1½”
Fitting dimensions DN40
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 5,1 m3/h Pressure loss 180 mbar
Key performance towerds the recooler
Nominal volume flow rate 5,1 m3/h Max. delivery height 600 mbar
Pressure loss 250 mbar
Weicht
Operational weight Ca. 150 kg
Demensions W x D x H (mm) 1138 x 749 x 1019 Oppervlakte opstelling 0,77 m2
Power drawn / Power connection Power drawn Max. 0,31 kW Power supply 230 V, 50 Hz
Supro system separation More than a plate heat exchanger
System separation for closed recooler / System separation for open recooler /
heat sink circuit ST-G-20 (KL10000075) heat sink circuit ST-O-20 (KL10000076)
Article number Left-side system separation KL10000076-L
Richt-side system separation KL10000076-R
Algemeen / prestaties Hydraulische aansluiting 2”
Aansluit diameter DN50
Max. hydraulische druk 4 bar
Specificaties circuit eCoo 2.0 of eZea volumestroom 10,2 m3/h
Hydraulische drukval 140 mbar
Specificaties Re-cool circuit Volumestroom 10,2 m3/h
Max. beschikbare opvoerhoogte 560 mbar
Hydraulische drukval 190 mbar
Gewicht
Gewicht leeg Ca. 150 kg
Afmetingen B x D x H (mm) 1171 x 678 x 1014
Oppervlakte opstelling 0,79 m2
Elektrische specificaties Elektrisch vermogen Max. 0,37 kW
Aansluitspanning 230 V, 50 Hz
Article number Left-side system separation KL10000075-L
Richt-side system separation KL10000075-R
General key performance Type of fitting 2”
Fitting dimensions DN50
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 10,2 m3/h
Pressure loss 140 mbar
Key performance towerds the recooler
Nominal volume flow rate 11,8 m3/h
Max. delivery height 650 mbar
Pressure loss 210 mbar
Weicht
Operational weight Ca. 150 kg
Demensions W x D x H (mm) 1171 x 678 x 1014
Oppervlakte opstelling 0,79 m2
Power drawn / Power connection Power drawn Max. 0,55 kW
Power supply 230 V, 50 Hz
Supro system separation More than a plate heat exchanger.
System separation for closed recooler / System separation for open recooler /
heat sink circuit ST-G-30 (KL10000077) heat sink circuit ST-O-30 (KL10000078)
Article number Left-side system separation KL10000078-L
Richt-side system separation KL10000078-R
General key performance Type of fitting Flange connection (PN6)
Fitting dimensions DN65
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 15,3 m3/h
Pressure loss 140 mbar
Key performance towerds the recooler
Nominal volume flow rate 15,3 m3/h
Max. delivery height 1030 mbar
Pressure loss 190 mbar
Weicht
Operational weight Ca. 226 kg
Demensions W x D x H (mm) 1206 x 967 x 946
Oppervlakte opstelling 1,17 m2
Power drawn / Power connection Power drawn Max. 1,5 kW
Power supply 400 V, 50 Hz
Article number Left-side system separation KL10000077-L
Richt-side system separation KL10000077-R
General key performance Type of fitting Flange conection (PN6)
Fitting dimensions DN65
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 15,3 m3/h
Pressure loss 140 mbar
Key performance towerds the recooler
Nominal volume flow rate 17,7 m3/h
Max. delivery height 790 mbar
Pressure loss 210 mbar
Weicht
Operational weight Ca. 226 kg
Demensions W x D x H (mm) 1206 x 967 x 946
Oppervlakte opstelling 1,17 m2
Power drawn / Power connection Power drawn Max. 0,8 kW
Power supply 230 V, 50 Hz
Supro system separation More than a plate heat exchanger.
System separation for closed recooler / System separation for open recooler /
heat sink circuit ST-G-30 (KL10000079) heat sink circuit ST-O-30 (KL10000080)
Article number Left-side system separation KL10000080-L
Richt-side system separation KL10000080-R
General key performance Type of fitting Flange connection (PN6)
Fitting dimensions DN65
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 20,4 m3/h
Pressure loss 159 mbar
Key performance towerds the recooler
Nominal volume flow rate 20,4 m3/h
Max. delivery height 1233 mbar
Pressure loss 215 mbar
Weicht
Operational weight Ca. 250 kg
Demensions W x D x H (mm) 1206 x 967 x 946
Oppervlakte opstelling 1,17 m2
Power drawn / Power connection Power drawn Max. 3 kW
Power supply 400 V, 50 Hz
Article number Left-side system separation KL10000079-L
Richt-side system separation KL10000079-R
General key performance Type of fitting Flange connection (PN6)
Fitting dimensions DN65
Max. operating pressure 4 bar
Key performance towerds the eCoo 2.0 of eZea Nominal volume flow rate 20,4 m3/h Pressure loss 159 mbar
Key performance towerds the recooler
Nominal volume flow rate 23,6 m3/h Max. delivery height 940 mbar
Pressure loss 240 mbar
Weicht
Operational weight Ca. 250 kg
Demensions W x D x H (mm) 1206 x 967 x 946 Oppervlakte opstelling 1,17 m2
Power drawn / Power connection Power drawn Max. 1,55 kW Power supply 230 V, 50 Hz
The specialist in the field of: “Cooling with Heat”
Parallelweg 10-31
7137 PE Lievelde
The Netherlands
Contact:
Dhr. N. Klein Gunnewiek, BEng
Telefoon: +31 (0) 6 8379 1555
Internet: www.supro-cooling.nl
E-mail: [email protected]
Supro Cooling is a part of Supro New Business B.V.
01-2017 ǀ All information are subject to change without prior notice. Technical modifications reserved.
SUPRO COOLING