2
 A B C D TEDOM cogeneration www.tedom.eu TEDOM a.s., Výčapy 195, 674 01 Třebíč, Czech Republic Pic: Configuration Containerized QUANTO Series NATURAL GAS - BIOGAS - LP G TEDOM CHP UNITS Basic Technical Data – NATURAL GAS CHP Unit Type Electric Output (kW) Heat Output (kW) Electric Efciency (%) Heat Efciency (%) Total Efciency (%) Gas Consumption (m 3 /h) SE CON SE CON SE CON SE CON SE CON SE CON Quanto D400 400 400 452 427 42,3 42,3 47,8 45,1 90,1 87,4 100 100 Quanto D580 600 600 693 654 42,0 42,0 48,5 45,8 90,5 87,8 151 151 Quanto D770 800 800 912 856 42,4 42,4 48,3 45,3 90,6 87,7 200 200 Quanto D1200 1 200 1 200 1 293 1 195 43,7 43,7 47,1 43,5 90,9 87,3 291 291 Quanto D1600 1 560 1 560 1 713 1 584 43,3 43,3 47,5 43,9 90,8 87,2 382 382 Quanto D2000 2 000 2 000 2 155 1 983 43,7 43,7 47,0 43,3 90,7 86,9 485 485  Abbrevi ation CON means CHP unit configuration containerized. Abbreviation SE means CHP unit configuration with sound enclosure. Basic Technical Data – BIOGAS CHP Unit Type Electric Output (kW) Heat Output (kW) Electric Efciency (%) Heat Efciency (%) Total Efciency (%) Gas Consumption (Nm 3 /h) SE CON SE CON SE CON SE CON SE CON SE CON Quanto D400 400 400 427 403 42,6 42,6 45,5 42,9 88,1 85,5 144 144 Quanto D580 600 600 649 610 42,5 42,5 46,0 43,2 88,5 85,8 217 217 Quanto D770 800 800 865 809 42,6 42,6 46,0 43,0 88,6 85,6 289 289 Quanto D1200 1 200 1 200 1 343 1 251 42,1 42,1 47,1 43,9 89,2 86,0 439 439 Quanto D1600 1 560 1 560 1 780 1 653 41,7 41,7 47,5 44,1 89,2 85,8 576 576 Quanto D2000 2 000 2 000 2 241 2 082 42,0 42,0 47,1 43,7 89,1 85,8 732 732  Abbrevi ation CON means CHP unit configuration containerized. Abbreviation SE means CHP unit configuration with sound enclosure. Dimensions and Weights CHP Unit Type  A (mm) B (mm) C (mm) D (mm) Operating Wei ght (kg) Quanto D400 CON 13 500 6 000 3 000 10 000 21 440 Quanto D580 CON 13 500 6 000 3 000 10 000 23 895 Quanto D770 CON 13 500 6 000 3 000 10 000 26 895 Quanto D1200 CON 15 000 6 000 3 000 10 000 37 125 Quanto D1600 CON 15 000 6 000 3 000 10 000 45 200 Quanto D2000 CON 16 500 6 000 3 000 10 000 54 535 Dimension and weight information about CHP unit of Quanto series with sound enclosure are available on request.

Tedom, Chp Bhkw

Embed Size (px)

Citation preview

  • QUANTOA

    B

    C

    D

    TEDOM cogeneration www.tedom.eu

    TEDOM a.s., Vapy 195, 674 01 Teb, Czech Republic

    Pic: Configuration Containerized

    QUANTO Series

    NATURAL GAS - BIOGAS - LPG

    TEDOM CHP UNITSBasic Technical Data NATURAL GAS

    CHP Unit TypeElectric

    Output (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (m3/h)

    SE CON SE CON SE CON SE CON SE CON SE CON

    Quanto D400 400 400 452 427 42,3 42,3 47,8 45,1 90,1 87,4 100 100

    Quanto D580 600 600 693 654 42,0 42,0 48,5 45,8 90,5 87,8 151 151

    Quanto D770 800 800 912 856 42,4 42,4 48,3 45,3 90,6 87,7 200 200

    Quanto D1200 1 200 1 200 1 293 1 195 43,7 43,7 47,1 43,5 90,9 87,3 291 291

    Quanto D1600 1 560 1 560 1 713 1 584 43,3 43,3 47,5 43,9 90,8 87,2 382 382

    Quanto D2000 2 000 2 000 2 155 1 983 43,7 43,7 47,0 43,3 90,7 86,9 485 485

    Abbreviation CON means CHP unit configuration containerized. Abbreviation SE means CHP unit configuration with sound enclosure.

    Basic Technical Data BIOGAS

    CHP Unit TypeElectric

    Output (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (Nm3/h)

    SE CON SE CON SE CON SE CON SE CON SE CON

    Quanto D400 400 400 427 403 42,6 42,6 45,5 42,9 88,1 85,5 144 144

    Quanto D580 600 600 649 610 42,5 42,5 46,0 43,2 88,5 85,8 217 217

    Quanto D770 800 800 865 809 42,6 42,6 46,0 43,0 88,6 85,6 289 289

    Quanto D1200 1 200 1 200 1 343 1 251 42,1 42,1 47,1 43,9 89,2 86,0 439 439

    Quanto D1600 1 560 1 560 1 780 1 653 41,7 41,7 47,5 44,1 89,2 85,8 576 576

    Quanto D2000 2 000 2 000 2 241 2 082 42,0 42,0 47,1 43,7 89,1 85,8 732 732

    Abbreviation CON means CHP unit configuration containerized. Abbreviation SE means CHP unit configuration with sound enclosure.

    Dimensions and Weights

    CHP Unit Type A (mm) B (mm) C (mm) D (mm) Operating Weight (kg)

    Quanto D400 CON 13 500 6 000 3 000 10 000 21 440

    Quanto D580 CON 13 500 6 000 3 000 10 000 23 895

    Quanto D770 CON 13 500 6 000 3 000 10 000 26 895

    Quanto D1200 CON 15 000 6 000 3 000 10 000 37 125

    Quanto D1600 CON 15 000 6 000 3 000 10 000 45 200

    Quanto D2000 CON 16 500 6 000 3 000 10 000 54 535

    Dimension and weight information about CHP unit of Quanto series with sound enclosure are available on request.

  • CENTOMICROD

    A

    B

    C

    AB

    C

    D

    Issued 03/2011Overview of manufactured types TEDOM CHP units

    CENTO SeriesMICRO Series

    Pic: Configuration with Sound Enclosure Pic: Configuration with Sound Enclosure

    Notes for data in all tables:

    Gas consumption is referenced for natural gas with heating value 34 MJ and at ambient conditions: 15 C, 101,325 kPa.Gas consumption is referenced for biogas with methane volume 65 %, at normal conditions (0 C, 101,325 kPa).Biogas mark means fuels incurred by biological decomposition e.g. gas from water treatment plants, agricultural concerns or communal landfill sites.

    Referenced data is for general purposes only. Consult with TEDOM factory or country area authorized TEDOM representative for specific application assistance. All rights reserved specifications subject to change. Tedom is a registered trademark of TEDOM a.s..

    Basic Technical Data NATURAL GAS

    CHP Unit Type ElectricOutput (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (m3/h)

    Micro T30 30 62 31,2 64,3 95,5 10,2

    Basic Technical Data BIOGAS

    CHP Unit Type ElectricOutput (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (Nm3/h)

    Micro T30 21 43,5 30,5 63,0 93,5 10,6

    Micro T30 * 28 58 29,8 62,0 91,8 14,5

    *Stoichiometric mixture

    Basic Technical Data LPG

    CHP Unit Type ElectricOutput (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (kg/h)

    Micro T30 30 66 29,2 64,6 93,8 8,1

    Dimensions and Weights

    CHP Unit Type A (mm) B (mm) C (mm) D (mm) Operating Weight (kg)

    Micro T30 1 700 780 1 650 1 300 1 100

    Basic Technical Data NATURAL GAS

    CHP Unit Type ElectricOutput (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (m3/h)

    Cento T80 76 122 33,6 53,9 87,5 23,9

    Cento T100 101 147 35,7 52,1 87,8 30,0

    Cento T160 160 225 36,8 51,8 88,6 46,0

    Cento T180 178 249 37,0 51,8 88,8 50,9

    Cento T200 200 276 37,4 51,7 89,1 56,6

    Basic Technical Data BIOGAS

    CHP Unit Type ElectricOutput (kW)Heat

    Output (kW)Electric

    Efficiency (%)Heat

    Efficiency (%)Total

    Efficiency (%)Gas Consumption

    (Nm3/h)

    Cento T80 77 121 33,3 52,6 85,9 35,5

    Cento T100 95 143 34,4 52,0 86,4 42,5

    Cento T120 125 178 35,8 51,1 86,9 53,7

    Cento T160 165 213 37,8 49,0 86,8 67,1

    Cento T180 177 226 38,0 48,6 86,6 71,7

    Cento T160 CON 165 196 37,8 45,0 82,9 67,1

    Cento T180 CON 177 208 38,0 44,7 82,7 71,7

    Abbreviation CON means CHP unit configuration containerized.

    Dimensions and Weights

    CHP Unit Type A (mm) B (mm) C (mm) D (mm) Operating Weight (kg)

    Cento T80 3 480 1 485 2 010 2 380 4 230

    Cento T100 3 480 1 485 2 010 2 380 4 290

    Cento T120 3 480 1 485 2 010 2 380 4 270

    Cento T160 3 980 1 685 2 200 2 650 5 100

    Cento T180 3 980 1 685 2 200 2 650 5 100

    Cento T200 3 980 1 685 2 200 2 650 5 735

    Cento T160 CON 5 000 2 490 2 700 5 000 7 200

    Cento T180 CON 5 000 2 490 2 700 5 000 7 200

    Abbreviation CON means CHP unit configuration containerized.

    It is possible to combine more units in one container.Technical specifications of these units and their configuration are available on request.