20
SIRADIŞI SALON TİPİ KLİMA SERİLERİ 2018

TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

S I R A D I Ş ISALON TİPİ KLİMA SERİLERİ2 0 1 8

Page 2: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi
Page 3: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

I-SH

INE

U-M

ATCH

INVE

RTE

R / O

N-O

FF

I-CR

OW

N II

02

01

03

Page 4: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi
Page 5: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

I-CR

OWN

II

54°CSOĞUTMA

TURBO MODU AKILLIDEFROST

ARIZA TEŞHİS(TANIMLAMA)

SESSİZDİZAYN

-30 °CISITMA

3D HAVAAKIMI

WİFİKONTROL

KONFORLUUYKU MODU

LED GÖSTERGE(EKRAN)

NEM ALMA ZAMANLAYICI(PROGRAMLAMA)

ÇOCUK KİLİDİPM2.5FİLTRE SİSTEMİ

7 FAN HIZI -18 °CSOĞUTMA

SOĞUK HAVAÜFLEME KORUMASI

OTOMATİKÇALIŞMA

YATAY VE DİKEYSALINIM

Page 6: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

4

Küçük frekans aralıkları ile çalışma teknolojisi ve optimize fan kontrolü, ortamda istenilen konfor şartlarını koruyarak düşük sıcaklıklarda nem alma imkanı sağlamaktadır.

D Ü Ş Ü KS I C A K L I K L A R D ANEM ALMA İMKANI

GREE I-CROWN II SERİSİ DÜŞÜK DIŞ HAVASICAKLIĞINDA ISITMA SİSTEMİ

GELENEKSEL BİR SALON TİPİ KLİMANINDÜŞÜK DIŞ HAVA SICAKLIĞINDA ISITMA SİSTEMİ

Klima ısıtmaya başlarken içeriye soğukhava üflemesi için iç ünite serpantin sıcaklığıhassas şekilde kontrol edilir.

S O Ğ U K H A V AÜFLEME KORUMASI

Gree’nin özel "GREE+” aplikasyonu sayesinde klima cihazınızı cep telefonu ve tablet bilgisayarınızla uzaktan kontrol edebilirsiniz.

Y E N İ N E S İ LWI-FI KONTROL*

Page 7: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

D A H A G E N İ ŞHAVA ÜFLEME110 cm dikey hava üfleme çıkışı sayesinde daha uzun ve güçlü hava üfleme mesafesi ve daha geniş hava üfleme açısı sağlamaktadır.

E K S T R E M H A V A Ş A R T L A R I N D AÜSTÜN PERFORMANS

-30°C ~ 54°C Hava Sıcaklıklarında Üstün Performans

Dış hava sıcaklığı 54°C olduğunda bile etkin soğutma

Dış hava sıcaklığı -30°C olduğunda bile yeterli ısıtma

I-Crown Geleneksel

I-Crown Geleneksel

50°C 50°C

-20°C -20°C

110 cm

52

40

Page 8: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

I - C R O W N I I S E R İ S İTEKNİK ÖZELLİKLER

EERP

SEER

Nem

Net

Besleme

Net

Ara T Ara T

Birim

2

m

W

WWWA

3

mmkg

m3

°C°C

mm

kg

kg2

m

mm

-

GVH24AK-K3DNC6A

5.118 24.0001.500 7.200 8.800

3.412 32.414 34.1881.000 10.020

340 2.140 3.250270 4.000

4000-18 54

58

50

1025

R410A

---

İç Ünite

Dış Ünite

Ara Tesisat

Model Kodu

Güç Kaynağı

A++ / A+ (Daha sıcak iklimde A+++)

SUPER

6

Page 9: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

7

Page 10: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

I-SH

INE

NEM ALMA ZAMANLAYICI(PROGRAMLAMA)

OTOMATİKFAN

AKILLIÖN ISITMA

SESSİZ DİZAYNKONFORLUUYKU MODU

OTOMATİKÇALIŞMA

YATAY VE DİKEYSALINIM

LED GÖSTERGE(EKRAN)

AKILLI AÇILIPKAPANAN PANEL

OTOMATİKYENİDEN BAŞLATMA

ENERJİTASARRUFU

ÇOCUK KİLİDİTURBO MODUAKILLIDEFROST

ARIZA TEŞHİS(TANIMLAMA)

WİFİKONTROL

8

Page 11: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

I serisinin sütunlu gövdesi sayesinde tasarım ve teknikmükemmel bir şekilde bir araya getirilmiş şık,

benzersiz bir görüntü elde edilmiştir.

S A N A T S A LSÜTUNLU GÖRÜNÜM

9

Page 12: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

Cihaz üzerindeki dokunmatik kontrol ile teknoloji,hayatınıza modern bir yaklaşım getiriyor.

K U L L A N I C I D O S T UDOKUNMATİK EKRAN

Üniteyi açtığınızda, panel otomatik olarak dönecektir. “Sol ve sağ salınım” ayarlandıktan sonra, daha geniş açılı salınım ve daha dengeli hava dağılımı için hava çıkışı otomatik olarak sağa ve sola dogru salınım ile dağıtılacaktır.Böylece odanın her köşesinde serinliğin tadını çıkarabilirsiniz

G E N İ Ş A Ç I L IS A L I N I M M O D U İ L EDAHA DENGELİ HAVA DAĞILIMI

Elmas çizgisinden esinlenmiş, yenilikçi ürün tabanı görünümü daha zarif hale getirmek için tasarlanmıştır.

E L M A S Ş E K L İ N D ETABAN

Ultra uzun dikey hava çıkışı, esnek yukarı ve aşağıhava yönlendirme kanatçıkları ile birlikte, geniş bir hava

besleme açısıyla büyük hacimde hava sirkülasyonu sağlar. Böylece iç ortam istenilen sıcaklığa hızla ulaşır.

Y E T E R L İ H A V AY O Ğ U N L U İ Ç İ

ULTRA UZUN HAVA ÇIKIŞI110 cm

10

Gree’nin özel "GREE+” aplikasyonu sayesinde klima cihazınızı cep telefonu ve tablet bilgisayarınızla uzaktan kontrol edebilirsiniz.

Y E N İ N E S İ LWI-FI KONTROL*

Page 13: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

11

I - S H I N E S E R İ S İTEKNİK ÖZELLİKLER

Model Kodu

Güç Kaynağı

Birim GVH24AK-K3DNC8A

4.094~24.225~29.684,41.200~7.100~8.700

6.483~30.025,6~32.4141.900~8.800~9.500190~2.220~3.700350~2.750~3.800

7,04,0

* EER ve COP değerleri EN 14511 ölçüm standartlarına göre hesaplanmaktadır.* Veriler ; Soğutma : Oda Sıcaklığı 27°C KT, 19°C YT- Dış ortam sıcaklığı 35°C KT Isıtma : Oda Sıcaklığı 20°C KT – Dış ortam sıcaklığı 7°C KT, 6°C YT Borulama mesafesi tek yönde 5 metre koşullarına göre tespit edilmiştir. Çalışma esnasında bu değerler ortamdaki koşullara bağlı olarak farklılık gösterebilir.* SEER ve SCOP, soğutma ve ısıtma çalışması için mevsimsel enerji verimlilik değeri olup EN 14825 ölçüm standartlarına göre hesaplanmıştır.

İç Ünite

Dış Ünite

48/42/39/35/3061/55/52/48/43458×1790×458

504000-5~43

-20~245767

955×700×39654.0

2.0

550

2030

BeslemeFaz/Gerilim/Frekans Besleme Kablosu Damar Adedi ve Kesiti 2

F/V/Hzadet x mm

İç Üniteden1/220-240/50

3x4Soğutma Kapasitesi (Min.~Nominal~Maks.) Soğutma Kapasitesi (Min.~Nominal~Maks.) Isıtma Kapasitesi (Min.~ Nominal~Maks.) Isıtma Kapasitesi (Min.~ Nominal~Maks.) Soğutma Enerji Tüketimi (Min~Nominal~Maks.) Isıtma Enerji Tüketimi (Min~Nominal~Maks.) Nominal Akım (Soğutma/Isıtma)EERCOP SEERSCOPSezonsal Enerji Sınıfı (SEER / SCOP) Nem Alma Kapasitesi

BTU/hW

BTU/hWWWA

W/WW/W

L/h

---

Hava Debisi

Ses Basınç SeviyesiSes Güç SeviyesiNet Ölçüleri (G×Y×D) Net Ağırlık

m /h3

dB (A) dB (A)

mmkg

Net Ağırlık

D.Ü. Hava DebisiSoğutmada Dış Hava Çalışma Sıcaklık Aralığı Isıtmada Dış Hava Çalışma Sıcaklık Aralığı Ses Basınç SeviyesiSes Güç Seviyesi

Net Ölçüleri (G×Y×D)

Şarj Edilen Soğutkan MiktarıSoğutkan Türü

m3/h°C°C

dB (A) dB (A)

mm

kg

kg-

Ara Tesisat Kablosu Damar Adedi ve KesitiŞarj Gerektirmeyen Ara Tesisat UzunluğuEk Soğutkan MiktarıBakır Boru Çapı (Sıvı)Bakır Boru Çapı (Gaz)İç-Dış Ünite Arasındaki Maksimum Kot Farkıİç-Dış Ünite Arasındaki Maksimum Uzunluk

adet x mmm

g/mmm (in) mm (in)

mm

Ara Tesisat

Soğutma:A++;Isıtma:A+ (Daha sıcak iklim A+++)

1480/1200/1060/750/570/750

R410A

Φ6.35 (1/4")Φ15.88 (5/8")

10,46 / 13,033,20 3,20

3,0

5x2,5

Page 14: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

12

Page 15: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

U-M

ATCH

INVE

RTE

R /

ON-O

FF

KONFORLUUYKU MODU

LED GÖSTERGE(EKRAN)

ÇOCUK KİLİDİTURBO MODUAKILLIDEFROST

ARIZA TEŞHİS(TANIMLAMA)

ENERJİTASARRUFU

YÜKSEKVERİM

KOLAYBAKIM

SOĞUK HAVAÜFLEME

KORUMASI

OTOMATİKTEMİZLİK

DÜŞÜK VE YÜKSEK VOLTAJDA

ÇALIŞMA

NEM ALMA ZAMANLAYICIYIKANABİLİRFİLTRE

KAPSAMLIKORUMA

-15 °C ISITMA YENİDENBAŞLATMA

GVH48AH

GVH24AL-GVA48AL

13

Page 16: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

Defrost, ısıtma konumunda dış ünitede oluşan ve ısı transferini engelleyen buzun eritilmesi işlemidir. Defrost kontrolü cihazın verimliliğini doğrudan etkiler. Klasik defrost zaman ayarına göre çalışır. Akıllı defrost özelliği, sadece ihtiyaç olduğunda devreye girerek defrost süresini kısaltır, ısıtma konforunu arttırır ve enerji tüketimini azaltır. Defrostu yeterince hassas yönetemeyen klimaların verimliliği yüksek gözükse bile konfor seviyeleri düşük, enerji tüketimleri yüksektir.

A K I L L IDEFROST

Kumanda üzerinden “Turbo“ düğmesine basıldığındaistenilen iç ortam konfor şartlarına daha kısa

sürede ulaşılır.

“ T U R B O ”ISITMA VE SOĞUTMA

GREE AKILLI DEFROST

ISITMA ISITMA ISITMA

(60DAK.) (70DAK.)(8DAK.) (5DAK.) (70DAK.)

DEFROST DEFROST

(50DAK.) (50DAK.) (50DAK.)(10DAK.) (10DAK.)

KLASİK DEFROST

ISITMA ISITMA ISITMA

DEFROST DEFROST

Yüksek hassasiyet ve güvenlik gerektiren elektronik kart ve elektrik bağlantı terminalleri, yalıtılmış metal kutu içerisine yerleştirilmiştir. Bu sayede yangın güvenliği sağlandıgı gibi dışarıdan müdahale ve darbe engellenir.

Y A N M A ZELEKTRİK KUTUSU

Düşük Sıcaklıklarda Soğutma ve Isıtma

Özel fan teknolojisi ve tasarımı sayesinde, U-Match Serisi Ticari Tip Klimalar düsük dış hava

sıcaklıklarında ısıtma ve soğutma yapabilmekte ve dört mevsim yüksek verimlilikle kullanılabilmektedir.

Soğuk Hava Üfleme Koruması

Klima ısıtmaya başlarken içeriye soğuk hava üflenmemesi için iç ünite serpantin sıcaklığı hassas

şekilde kontrol edilebilir.

D Ü Ş Ü KSICAKLIKLARDA ÇALIŞMA

14

Page 17: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

Model Kodu

Güç Kaynağı

Soğutma Kapasitesi (Min.~Nominal~Maks.) Soğutma Kapasitesi (Min.~Nominal~Maks.) Isıtma Kapasitesi (Min.~ Nominal~Maks.) Isıtma Kapasitesi (Min.~ Nominal~Maks.) Soğutma Enerji Tüketimi (Min~Nominal~Maks.) Isıtma Enerji Tüketimi (Min~Nominal~Maks.) Nominal Akım (Soğutma/Isıtma)EER COP SEER SCOPSezonsal Enerji Sınıfı (Soğutma/Isıtma)

İç Ünite

Dış Ünite

Ara Tesisat

BeslemeFaz/Gerilim/FrekansBesleme Kablosu Damar Adedi Kesiti

Model Kodu

Dış Ünite Model Kodu

Birim

--F/V/Hz

adet x m3

BTU/hW

BTU/hWkWkWA

W/WW/W

------

--

m3/hdB (A) dB (A)

mmkg

--

m3/h°C°C

dB (A) dB (A)

mmkg--kg

adet x mm2

mgr/m

mm (inch)mm (inch)

mm

GVH24AL-K3DNC7A Dış Üniteden1/220~240/50

3x4,03.412-24.567-33.4381.000~7.200~9.800

5.459-25.590-37.8731.600-7.500-11.100

0,37-2,25-3,70,32-2,08-3,8

10,5 / 9,53,213,616,104,0

A++ / A+GVH24AL-K3DNC7A/I

1400/1150/1050/90049/45/42/3965/57/53/50

507x1170x32040

GVH24AL-K3DNC7A/O

3200-15~43-15~24

6070

955×700×39654

R410A2,0

(4x2,5)5

50ø6,35 - (1/4)"ø15,88 - (5/8)"

1025

Hava DebisiSes basınç seviyesiSes güç seviyesiNet Boyutlar (G×Y×D) Net Ağırlık

Dış Ünite hava debisiSoğutmada Dış Hava Çalışma Sıcaklık AralığıIsıtmada Dış Hava Çalışma Sıcaklık AralığıSes Basınç SeviyesiSes Güç SeviyesiBoyutlar (G×Y×D) AğırlıkSoğutkan TürüŞarj Edilen Soğutkan MiktarıAra Tetsisat Kablosu Damar Adedi ve KesitiŞarj Gerektirmeyen Ara Tesisiat UzunluğuEk Soğutkan MiktarıBakır boru Çapı (Sıvı)Bakır boru Çapı (Gaz)İç- Dış Ünite Arasındaki Maks. Yükseklik Farkıİç- Dış Ünite Arasındaki Maks. Uzunluk

GVH48AH-M3DNA5A Dış Üniteden3/380~415/50

5x4,010.236-42.000-44.3563.000~12.000~13.00011.601-12.000-14.0003.400-13.600-14.000

0,66-4,2-4,40,7-4,2-3,86,0 / 6,50

33,245,103,80A / A

GVH48AH-M3DNA5A/I

1.850/1.800/1.700/1.53052/50/48/4563/61/58/56

580x1.870x40058

GVH48AH-M3DNA5A/O

2.00018~43-15~24

6370

1.107×1.100×44094

R410A3,5

(4x2,5)5

50ø9,52 - (3/8)"ø15,88 - (5/8)"

1025

U - M A T C H I N V E R T E RTEKNİK ÖZELLİKLER

* EER ve COP değerleri EN 14511 ölçüm standartlarına göre hesaplanmaktadır.* Veriler ; Soğutma : Oda Sıcaklığı 27°C KT, 19°C YT- Dış ortam sıcaklığı 35°C KTIsıtma : Oda Sıcaklığı 20°C KT – Dış ortam sıcaklığı 7°C KT, 6°C YTBorulama mesafesi tek yönde 5 metre koşullarına göre tespit edilmiştir.Çalışma esnasında bu değerler ortamdaki koşullara bağlı olarak farklılık gösterebilir.* SEER ve SCOP, soğutma ve ısıtma çalışması için mevsimsel enerji verimlilik değeri olupEN 14825 ölçüm standartlarına göre hesaplanmıştır.

15

Page 18: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

U - M A T C H O N / O F FTEKNİK ÖZELLİKLER

* EER ve COP değerleri EN 14511 ölçüm standartlarına göre hesaplanmaktadır.* Veriler ; Soğutma : Oda Sıcaklığı 27°C KT, 19°C YT- Dış ortam sıcaklığı 35°C KTIsıtma : Oda Sıcaklığı 20°C KT – Dış ortam sıcaklığı 7°C KT, 6°C YTBorulama mesafesi tek yönde 5 metre koşullarına göre tespit edilmiştir.Çalışma esnasında bu değerler ortamdaki koşullara bağlı olarak farklılık gösterebilir.* SEER ve SCOP, soğutma ve ısıtma çalışması için mevsimsel enerji verimlilik değeri olupEN 14825 ölçüm standartlarına göre hesaplanmıştır.

Model Kodu

Güç Kaynağı

Soğutma Kapasitesi (Min.~Nominal~Maks.) Soğutma Kapasitesi (Min.~Nominal~Maks.) Isıtma Kapasitesi (Min.~ Nominal~Maks.) Isıtma Kapasitesi (Min.~ Nominal~Maks.) Soğutma Enerji Tüketimi (Min~Nominal~Maks.) Isıtma Enerji Tüketimi (Min~Nominal~Maks.) Nominal Akım (Soğutma/Isıtma)EER COP SEER SCOPSezonsal Enerji Sınıfı (Soğutma/Isıtma)

İç Ünite

Dış Ünite

Ara Tesisat

BeslemeFaz/Gerilim/FrekansBesleme Kablosu Damar Adedi Kesiti

Model Kodu

Dış Ünite Model Kodu

Birim

--F/V/Hz

adet x m3

BTU/hW

BTU/hWkWkWA

W/WW/W

------

--

m3/hdB (A) dB (A)

mmkg

--

m3/h°C°C

dB (A) dB (A)

mmkg--kg

adet x mm2

mgr/m

mm (inch)mm (inch)

mm

GVA48AL-M3NNC7A Dış Üniteden3/380~415/50

5x4,048.11014.10052.88615.500

5,04,53+3,5

9,9/7,3+9,22,823,21

------

GVA48AL-M3NNC7A/I

1.80052/50/48/4562/60/58/55

587x1882x39461

GVA48AI-M3NNC7A/O

6.00018~43

-15~245969

1.032×1.250×412107

R410A4,1

(5x2,5) + (2x1,5)5

120ø12,7 - (1/2)"ø19,05 - (3/4)"

2030

Hava DebisiSes basınç seviyesiSes güç seviyesiNet Boyutlar (G×Y×D) Net Ağırlık

Dış Ünite hava debisiSoğutmada Dış Hava Çalışma Sıcaklık AralığıIsıtmada Dış Hava Çalışma Sıcaklık AralığıSes Basınç SeviyesiSes Güç SeviyesiBoyutlar (G×Y×D) AğırlıkSoğutkan TürüŞarj Edilen Soğutkan MiktarıAra Tetsisat Kablosu Damar Adedi ve KesitiŞarj Gerektirmeyen Ara Tesisiat UzunluğuEk Soğutkan MiktarıBakır boru Çapı (Sıvı)Bakır boru Çapı (Gaz)İç- Dış Ünite Arasındaki Maks. Yükseklik Farkıİç- Dış Ünite Arasındaki Maks. Uzunluk

16

Page 19: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi

Bu katalogta yer alan spesifikasyonlar, tasarım ve bilgiler haber vermeksizin değiştirilebilir. Baskı ve tipografik hatalardan firmamız sorumlu değildir.

NOTLAR

Page 20: TLC SALON TIP KTG 2018 FINAL WEB · Net Ölçüleri (G×Y×D) Şarj Edilen Soğutkan Miktarı Soğutkan Türü m3/h °C °C dB (A) dB (A) mm kg kg-Ara Tesisat Kablosu Damar Adedi