76
ABB Power Technologies AB © 2006-04-20 Carl Öhlén Rio de Janeiro April 23-25, 2006 Um IED com conceito modular e prova de futuro Carl Öhlén

Um IED com conceito modular e prova de futuro - …€¦ · ABB Power Technologies AB ... de 100 anos experiência de reles convencionais e mais de 20 anos experiência de communciation,

  • Upload
    lamngoc

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

AB

B P

ower

Tec

hnol

ogie

s A

B© 2006-04-20 Carl Öhlén

Rio de JaneiroApril 23-25, 2006

Um IED com conceito modular e prova de futuro

Carl Öhlén

2

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Uma atividade globalGlobal Center HV SA Products

Västerås, Sweden (IEDs & Cx)Vaasa, Finland (MicroSCADA)Mannheim, Germany (RTU)

Global Center MV SA ProductsVasa, Finland (DA)

Global Center SA SystemBaden Switzerland

Local centersAllentown, U.S. (ANSI)Coral Springs, U.S. (EM)India, China, Russia (LP)Local Engineering Centers

Local Sales, Service & Support

3

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Um conceito modular de IED à prova de futuro

Por que nós precisamos de proteção e controleIntroduzindo a aplicação de ABB de IEC 61850Vantagens para um conceito aberto e modular

Confiavel - Melhorando a confiabilidade da rede eletricaEficiente - Muito mais que apenas um reléFlexivel - Exatamente o que voce precisa e você querAmigável - Fácil selecionar, ajustar, instalar e usarInformativo - Concebido para comunicarEternamente jovem - Seguro e confiável para o futuro

4

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Imagine um mundosem eletricidade

5

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Blecautes de verão quentes2003…2004…

…continuado em 2005

Moscow

Dubai

6

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Porque precisamos proteção e controle confiáveis ?

Descobrir rapidamente e desconectar todas as faltascom efeito de mínimo para a operação de sistemaInformar sobre condiçõesoperacionais e iniciar açõesnecessáriasFacilitar a restauraçãoautomática e manual rapidamente a operaçãonormalProver avaliação, informaçãoe controle para operaçãoeficiente, manutenção & administração de recurso

7

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Isto inclui detectar todos tipos de faltas

ESA SBA B

ZsA ZsB

Z<

p*ZL 1-p*ZL

Rf

Z<

IAIA IBFaltas em fim de linha fracoFaltas e correntes grandes com muita componente DC

IL

Faltas durante alta carga (IL)

3- phase faults

2- phase faults

Faltas de alta impedância

Evolving faults

1- phase faults

8

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

E opere corretamente independente de transitórios

Transitórios no primárioEx: Corrente de energizacãode trafo e power swings

Transitórios no secundário:Ex: saturacão de TCs e transitórios em TPCs

currentin pu

time in ms

iL1

iL2

iL3

10.0

0 20 40 60 80 100

5.0

0.0

-5.0

phase L3 current

phase L1 current

CBcloses

currentin pu

time in ms

iL1

iL2

iL3

10.0

0 20 40 60 80 100

5.0

0.0

-5.0

phase L3 current

phase L1 current

CBcloses

Filtragem avançada:• Compensação de 2º e 3º e 5º harmônicos• Detecção de saturação de TC´s• Detecção de remanescência de TC´s• Compensação para transitórios

9

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Informação correta para agir corretamente

Conserto e Manutenção

Serviçopara

clientes

Automatizaçãode subestação

Cliente

Administraçãode recurso Engenharia

Venda

Contabilidade

Centro de Controle e Escritório

10

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Por que nós precisamos de tantos protocolos?

IEC60870-6 (TASE2)IEC61970 (CIM)

Centro de Controle

Centro de Controle

Automatização de subestação

Automatização de subestação

SPA, LON, DNP 3.0, MODBUS, UCA 2, Profibus, IEC60 870-5-103, K-Bus, ZZZ

SCADAIEC60870-5-101IEC60870-5-104DNP 3.0ELCOM 90RP570/571XXX

Metering & BillingIEC61107IEC62056IEC60870-5-102YYY

WindfarmsIEC51400-25

IEC G703IEEE C37.94WWW

IEC 61850

IEC 61850= IEC 61850

11

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

O que? Onde? Quando? Quem? O qual? então Como?

IED IHM

Subestação IHSI

Centro de Controle Escritório CAsa Em qualquer lugar(On-line) (Em pedido)

Information and control access

Subestação(Automático)

12

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Proteja seu investimento e garanta o fornecimento de energia

O O objetivoobjetivo principal principal éé sempresemprea a proteproteççãoão e e controlecontrole com a com a mmááximaximaconfiabilidadeconfiabilidade e e disponibilidadedisponibilidade

Subestações convencionais(AIS) Sistemas HVAC e HVDC

Subestações blindadas (GIS) Geração

13

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Um conceito modular de IED à prova de futuro

Por que nós precisamos de proteção e controleIntroduzindo a aplicação de ABB de IEC 61850Vantagens para um conceito aberto e modular

Confiavel - Melhorando a confiabilidade da rede eletricaEficiente - Muito mais que apenas um reléFlexivel - Exatamente o que voce precisa e você querAmigável - Fácil selecionar, ajustar, instalar e usarInformativo - Concebido para comunicarEternamente jovem - Seguro e confiável para o futuro

14

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

O próximo passo em tecnologia para ABBABB tem produtos e sistemas paraProteção, Controle e Automatização do sistema completo

Nossos produtos são uma evolução de maisde 100 anos experiência de relesconvencionais e mais de 20 anos experiênciade communciation, controle, proteção e automatização de subestação digital (ASEA, BBC, Westinghouse, Strömberg)

ABB entregou mais de 10 milhões de relés e 500 000 IEDs para mais de 100 países emtodos os continentes

Agora nós introduzimos um conceitoaberto novo e sem igual que éprojetado para o padrão = IEC 61850IED670, PCM 600 e MicroSCADA Pro

15

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

O próximo passo na evolução dos IED100 – series200 – series300 – series500 – series

+ capacidade aumentada (600 MHz)+ 24 entradas analógicas+ algoritmos aumentados+ funcionalidade aumentada+ ferramentas melhoradas (PCM)+ HMI melhorado (6 paginas)+ Implementação de IEC 61850

completa= introduzindo IED 670

UM IED poderoso e aberto para TODAS as aplicações

16

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Um IED à prova de futuro para TODAS as aplicações

17

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Um passo principal em automatização de subestaçãoIED = Intelligent Electronic Device

IED 670 pode ser configurado para proteção e controle de todas as aplicações de transmissão

REL 670 = Linhas e cabosRET 670 = Transformadores e “Multi” objetos

RED 670 = Redes com términos múltiplosREC 670 = Controle para 6 bays e 30 objetos

REB 670 = Barra e disjuntorPCM 600 = Ferramenta de usário

MicroSCADA Pro, GW e RTU

ABB introduzem o primeiro conceito aberto

para proteção e controle do sistema de

transmissão, projetados para o novo IEC 61850 padrão

18

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Introduzindo IEC 61850 em proteção e controle

A habilidade para IED.s de um ou váriosfabricantes para trocar informação e usar a

informação para as próprias funçõesdeles/delas

O padrão apoiará arquitetura diferente e permitirá uma distribuição livre de funções, por

exemplo tem que trabalhar igualmente bempara centralizou ou descentralizou sistemas.

O padrão será prova futura, i.e. deve poderseguir o progresso em tecnologia de

comunicação como também evoluindorequerimentos de sistema

19

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

O que é 61850 Comunicação Aberta?Conceito básico:

Ethernet 100 MBpsStation Bus 61850 8-1 Process Bus 61850 9-2 Comunicação Bay-to-bay (Goose)Modele para objeto comum (Logical Nodes) e idioma de configuração (SCL)

Muito mais que um protocolo:Modularization e estruturando de dadosNodos lógicos unificadosTraçando de funções em qualquer IEDEngenharia & serviços estruturada

“Combining the best properties in a new way...”

Um modo seguro, simples e rápido para construir sua automatização de

subestação à prova de futura

20

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

A Experiência de ABBMais de 20 anos de experienciade EMS, SCADA, SA e DA

ABB é o líder global em automatizaçãoPrimeiro Ethernet SA & SPA 1984Primeiro LON SA 1994

Participação ativa em comitês de padronização

13 sócios permanentes em TC57!

Prova” interoperability” extensa com Areva, Siemens e Omicron

Referências com IEC 61850Primeiro instalação de voltagens alta emserviço com vários vendedores> 50 estações em ordem> 200 propostas de projeto

Part 6Substation Configuration Language (SCL)Communication model Parts 7-1 to 7-4

Communication requirements Part 5

System and Project management Part 4

Glossary Part 2

Introduction and overview Part 1

General requirements Part 3

Part 10Conformance testing

Part 9Part 9-1

Part 9-2

Part 8-1 : Mapping for MMS-TCP/IP-Ethernet

Part 8-x : for Future Use

100 Mbit/s redundant switched Ethernet ring

Bay Level

Station Level/ Gateway

IEC101

GPS

Kema Simulator

KemaAnalyser

380kV Laufenburg

21

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Interoperability demonstração (Junho 2005 Brasil)

22

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Agora nós estamos prontos!

23

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Automatização de subestação para 61850Controle remoto(COS) Escritório

Nivel de Bay

Nível de estação

Station or interbay bus (LAN)Optical EthernetIEC61850-8-1

Station ComputerIHM

StationGatewayou RTU

REB 670 REC 670REL 670RED 670 RET 670

SMS & PCMTCP/IP LAN

Station or interbay bus (LAN)Optical LON

Optional IEC 870-5-103 or SPA

Process bus (LAN)IEC61850-9-2

Remote binary and analoguesignal transfer

24

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

GOOSE - Comunicação horizontal para TODO o IEDs

GOOSE = Generic Object Oriented System-wide Events

ProteçãoControleProteçãoControle Proteçãoe controle

GOOSE

Dados ser enviado a outro IEDs estãodefinidos na ferramenta de engenharia

Comunicação rápida e horizontal entre os IEDs

Um IED envia informação através de multicasting

Só IEDs que é definido para escutar (os subscritores) recebaesta mensagem

25

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

I/O modular em diferentes caixas e IHM

1/1 Case

Option 1:•1TRM = 12 AI•< 14 I/O modules

Option 2:•2TRM = 24 AI•< 11 I/O modules

BIM(max 11/14)

16 binary inputs

BOM(max 4)

24 binary outputs

IOM(max 6)

6 Transducer inputs,setting range +

Os mesmos módulos de I/O como nas séries de REx5xx

20 mA

MIM(max 4)

12 binary outputsand 8 binary inputs

26

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Biblioteca de função independente de hardware

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27PGPF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

B24PDIFC 87B Proteção diferencial de barra 24 baysL6CPDIF 87L Proteção diferencial de linha 6 x 3 entradasT3WPDIF 87T Proteção diferencial de transformador 3 x 2 x 3 entradasREFPDIF 87N Proteção diferencial de baixa impedânciaHZ PDIF 87 Proteção diferencial de alta impedância

ZMQPDIS 21 Proteção de distância5 e 2 x 2 zonas Esquema completo

PH4POCM 51/67 Proteção de sobrecorrente (Fase) 4 steps x 6

EF4PEFM 51N/67N Proteção de sobrecorrente (Terra) 4 steps x 6

POVM 27/59 Proteção de subtensão PTUF 81 Proteção de subfrequenciaPTOF 81 Proteção de sobrefrequenciaPVPH 24 Proteção de sobrexcitaçãoLPTTR 26 Proteção de sobrecarga térmicaPGPF XXX Proteção geral programável de tensão e corrente personalizadoCRBRF 50BF Proteção contra falha de disjuntorRSYN 25 Sincronismo e verificação de energizaçãoRREC 79 ReligamentoCSWI Controle 6 bays / 30 objetosRFLO Localizador de faltasRADR Relatório de distúrbios 100 x 40MMXU MediçõesMMTR Contador de pulsos

Este é um exemplo de funções incluído na biblioteca. Para detalhes cheios por favor consulte o guia de comprador.

27

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Distribuição flexível de funções para qualquer IED

PDIS21

RREC79

MMTR

PDIS21

POCM51/67

RBRF50BF

RREC79

RSYN25

MMXUMMTRCSWI

PDIF87L

PDIS21

PDIFHZ

POCM51/67

RBRF50BF

RREC79

RSYN25

MMXUMMTRCSWI

PDIF87T

PGPF

PVPH24

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27PGPF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

B24PDIFC 87B Proteção diferencial de barra 24 baysL6CPDIF 87L Proteção diferencial de linha 6 x 3 entradasT3WPDIF 87T Proteção diferencial de transformador 3 x 2 x 3 entradasREFPDIF 87N Proteção diferencial de baixa impedânciaHZ PDIF 87 Proteção diferencial de alta impedância

ZMQPDIS 21 Proteção de distância5 e 2 x 2 zonas Esquema completo

PH4POCM 51/67 Proteção de sobrecorrente (Fase) 4 steps x 6

EF4PEFM 51N/67N Proteção de sobrecorrente (Terra) 4 steps x 6

POVM 27/59 Proteção de subtensão PTUF 81 Proteção de subfrequenciaPTOF 81 Proteção de sobrefrequenciaPVPH 24 Proteção de sobrexcitaçãoLPTTR 26 Proteção de sobrecarga térmicaPGPF XXX Proteção geral programável de tensão e corrente personalizadoCRBRF 50BF Proteção contra falha de disjuntorRSYN 25 Sincronismo e verificação de energizaçãoRREC 79 ReligamentoCSWI Controle 6 bays / 30 objetosRFLO Localizador de faltasRADR Relatório de distúrbios 100 x 40MMXU MediçõesMMTR Contador de pulsos

Este é um exemplo de funções incluído na biblioteca. Para detalhes cheios por favor consulte o guia de comprador.

28

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Configurar seu melhor IED da biblioteca

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27PGPF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

G

M

RET 670

REB 670

REL 670

RED 670

REB 670

RET 670

RED 670

Você pode configurar até mesmo um IED para proteção de transformador, proteção de linha, proteção de barra e controle ao mesmo tempo

Você pode atualizar e pode mudar o IED qualquerhora a (até mesmo on-line em cima de LAN/Ethernet)

29

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Configurar seu melhor IED da biblioteca

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27PGPF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

PDIS21

PDIFHZ

POCM51/67

PEFM51/67N

RREC79

RSYN25

MMTR MMXU

PDIS21

PDIFHZ

POCM51/67

PEFM51/67N

RREC79

RSYN25

MMTR MMXU

PDIF87L

RBRF50BF

RBRF50BF

POVM59

PDIS21

PDIFHZ

POCM51/67

PEFM51/67N

RREC79

RSYN25

MMTR MMXU

RBRF50BF

RBRF50BF

POVM59

PDIF87T

RBRF50BF

RBRF50BF

CSWI

CSWI

CSWI

CSWI

PVPH24

PTTR26

REL 670

RED 670

RET 670

30

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Bus 1A

CB 1

Line 1A

Line 1B

CB 2

Transformer 1A

Transformer 1B

T- connection

CB 3

Bus 2 A

Bus 1B

Bus 1B

Control 1

Control 3

Você pode distribuir funções a qualquer IED

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27

RBRF50BF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

Exemplo para disjuntor e meia

Control 3

31

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Bus 1A

CB 1

Line 1A

Line 1B

CB 2

Transformer 1A

Transformer 1B

T- connection

CB 3

Bus 2 A

Bus 1B

Bus 1B

Control 1

Control 3

Control 3

PDIS21

PDIF87L

RBRF50BF

RBRF50BF

RBRF50BF

PDIF87B

PDIF87B

PDIF87B

PDIF87B

PDIFHZ

PDIF87B

PDIS21

CSWI

CSWI

CSWI

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27

RBRF50BF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

Você pode distribuir funções a qualquer IEDExemplo para disjuntor e meia

32

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Bus 1A

CB 1

Line 1A

Line 1B

CB 2

Transformer 1A

Transformer 1B

T- connection

CB 3

Bus 2 A

Bus 1B

Bus 1B

Control 1

Control 3

Control 3

Por exemplo RBRF (50BF) e PIOC (50)

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27

RBRF50BF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

Exemplo para disjuntor e meia

33

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Bus 1A

CB 1

Line 1A

Line 1B

CB 2

Transformer 1A

Transformer 1B

T- connection

CB 3

Bus 2 A

Bus 1B

Bus 1B

Integração funcional em qualquer IEDPDIF87B

PDIF87B

PDIS21

PDIF87L

PDIS21

PEFM51/67N

RBRF50BF

RBRF50BF

RREC79

RREC79

MMXU

MMTRCSWi

PDIF87T

PDIFHZ

RBRF50BF

PDIS21

PDIFHZ

PDIFHZ

Exemplo para disjuntor e meia

REB 670

REL 670

RED 670

REC 670

RET 670

REL 670

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27

RBRF50BF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

34

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Bus 1A

CB 1

Line 1A

Line 1B

CB 2

Transformer 1A

Transformer 1B

T- connection

CB 3

Bus 2 A

Bus 1B

Bus 1B

Movimento, mudança e atualização a qualquer horaPDIF87B

PDIF87B

PDIS21

PDIF87L

PDIS21

PEFM51/67N

RBRF50BF

RBRF50BF

RREC79

RREC79

MMXU

MMTRCSWi

PDIF87T

PDIFHZ

RBRF50BF

PDIS21

PDIFHZ

PDIFHZ

Exemplo para disjuntor e meia

REB 670

REL 670

RED 670

REC 670

RET 670

REL 670

POVM59

PVPH24

RBRF50BF

RREC79

MMXUMMTR

RSYN25

CSWI

PTUF81

PTOF81

PSCHPTTR26

POVM59

PVPH24

POCM51/67

PIOC50N

PUVM27

RBRF50BF

PIOC50

PEFM51/67N

PDIFREF

PDIFHZ

PDIF87T

PDIF87L

PDIS21

PDIF87B

35

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Hardware diferenteSoftware diferenteConvertedores de protocolodiferentesReservas diferentesFerramentas DiferentesManutenção DiferenteMuito aprender e administrar

O modo velho com muitos “Caixas”

36

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

ABB apresenta a primeira conceito de IED para proteção e controle de transmissão completamenteprojetados para IEC 61850 padrãoabertoUM IED comum de classe de transmissão para toda a proteção & controle aplicaçõesUMA Biblioteca de Função de Aplicação comum com algoritmosexecutando altos que são hardware independenteUM conceito comum para TODAS as aplicações de transmissão

Um passo principal em automatização de subestação

37

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

UM IED 670 para TODA a TransmissãoREL 670 (Linhas e cabos)RED 670 (Redes com términos múltiplos)RET 670 (Transformadores e “Multi” objetos ) REB 670 (Barra e disjuntor)REC 670 (6 bays e 30 objetos)

UMA ferramenta PCM 600Configuração & AjustesMonitorando eventos & perturbação

UMA MicroSCADA ProAutomatização de subestação & IHMGateway independente ou integrado

Um SA conceito projetou para o IEC 61850 padrão aberto

O primeiro SA conceito projetou para IEC 61850

38

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Você decide o que você querO mesmo desígnio velho

Separe proteção primária e secundária

Controle separado em RTU

Mas com seletividade e funcionalidade melhoradaAlgoritmos paralelos (E.g. 87T, 87, 21, 4x 51/ 67)

Até 24 entradas separado (87T, 87L)

Você pode integrar proteção e controleToda a proteção e controla em um IED

Conexão separada para nucleus (TC/TV) de medecion e proteção

Você pode aperfeiçoar proteção e controleFuncionalidade

Confiabilidade

Economia

39

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Um conceito modular de IED à prova de futuro

Por que nós precisamos de proteção e controleIntroduzindo a aplicação de ABB de IEC 61850Vantagens para um conceito aberto e modular

Confiavel - Melhorando a confiabilidade da rede eletricaEficiente - Muito mais que apenas um reléFlexivel - Exatamente o que voce precisa e você querAmigável - Fácil selecionar, ajustar, instalar e usarInformativo - Concebido para comunicarEternamente jovem - Seguro e confiável para o futuro

40

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Solução modular única com biblioteca funcional extensiva e cartões de I/O para proteção e controle expansíveis.

Modular e independente de hardwarepara TODAS as aplicações em Sistemas de Transmissão de EnergiaOs IEDs 670 foram integralmente desenvolvidos para o IEC 61850, TCP/IP e Ethernet de Alta-VelocidadePode controlar objetos e algoritmos múltiplos dentro paralelo

Fornece soluções de automação de subestações eficiente para qualquer aplicação de alta tensão

Eficiente

Apresentando o IED mágico

41

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

O mais poderoso “relé” jamais projetado

42

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

A/D5 kHz

~~~

~~~

Fundamental 50/60 Hz2nd, 3rd, 5th

Memoria, IHM, IEC 61850, IEC 60870-5-103, SPA, LON, TCP/IP etc.

Comunicação remota (Digital e análogo)

PSCHRREC

RDREMMTR

RSYN

RFLO

PDISPTOF

RDIFPGPF

PTUF

PFRC

PTOCRBRF

POVMPUVM

PTTR

RPLD

PSOFRPSB

PEFMPOCM

PDIS

PIOS Logic

Trip&

SignalMatrix

PTRC

GGIO

I/O

24 Entradas Análogicas(Corrente e Tensão)

Registro para100 perturbaçõesem 40 canais

600 MHz CPU com todas as funções

descritas comoIEC 61850

600 MHz CPU com todas as funções

descritas comoIEC 61850

14 módulos de E/S binárias (Exemplo 96 SB + 160 EB)

O mais poderoso “relé” jamais projetado

43

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

UM IED aberto projetou para IEC 61850

Estado-de-o-arte 600 MHz CPUProcesso rápido e preciso de

algoritmos de desempenho altosPossibilidade para processar vários

algoritmos executando altos en paralelo

Até 24 entradas análogosPara disjuntores, enrolamentos,

conexões e objetos múltiplosTáxi seja conectado a nucleos TC/TV

para proteção e medida

Página múltipla para HMI e I/O modular6 bays e 6 paginas250 BI/BOPode integrar proteção e controle

44

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Selecione da Biblioteca de Função de Aplicação

Para qualquer aplicação

45

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Já introduzindo o IED mais confiável projetaram

Conceito de desempenho alto sem igual para TODAS as aplicações de transmissão em UM IED

Experiência longa e conhecimento largo -“Made in ABB” assegura algoritmos confiávelsIED/CPU poderosa (Clase Transmissão) dá operação mais rapidamente e mais precisa Múltiplo algoritmos adaptáveis sem igual asseguram confiança de máximo e segurança com velocidade e seletividade.Evolução dos bem provados 316 e 500 assegura qualidade

Um grande passo para a confiabilidade da rede eletrica - Made in ABB

Confiável

46

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Based on Power System Know-how and experienceConfiabilidade = Velocidade + SensibilidadeSegurança = Seletividade + Estabilidade

REB 670 RTDS simulaçãocom 10 ms tempo operacional

47

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Aperfeiçoando a proteção de sua rede

½ Ciclo para barras e

transformador

1 Ciclo para Linhae ½ ciclo

com sobrecorrente

Faltas entre espirasinterna ao enrolamento

- saturação de TCs

Disparo mono, bi e/ou tripolar ,

elevado carregamentoAlgoritmos paralelos

48

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Flexível

Exatamente o que você querSistema aberto sem igual que pode ser configurado para integrado ou pode ser distribuído arquitetura de controle e proteção

Configurado para toda a proteção e aplicações de controle....... ou liberdade para distribuir todas as funções & nodos lógicos em qualquer IEDBiblioteca sem igual de algoritmos aperfeiçoados e algotim aberto para resolver funções especiais

Você pode costurar a proteção & controle de sua subestação para o desempenho, redundância e custo que você quer ter

49

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Selecione seu hardware perfeito

50

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Pre-configuados ou aberto

51

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Selecione sua arquitetura preferidaIntegração, redundância, etc.

Estabeleça tipo e número de IEDsREL, RED, RET, REC, REB

Decida funcionalidade de IEDdentifique a necessidade por I/OSelecione o tamanho (½ , ¾, 1/1 ) Selecione qual tipo de IHM

Selecione qual tipo de comunicaçãoCarregue sua configuraçãoConecte a circuito primárioAjustes e ponha em serviço

Pronto operar mas você pode mudare pode atualizar a qualquer hora

UM conceito modular para TODAS as aplicações

52

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Gerenciamento de dados de informações único, oscilografia e eventos com integração “sem costuras” para TCP/IP, MicroSCADA Pro e via conceito gateway da ABB.

Monitoring communication for up to 40 analog channels and 100 disturbances per IEDProtection communication with built in analog and binary remote communication (transfer trip + Id)Control communication with built in optical Ethernet ports (2 + 2) for IEC 61850

Disponibilidade melhorada e gerenciamento de ativos através de informação certa, no tempo certo, para o usuário certo, para decisões certas

com municate

informativo

Informação certa em tempo certa para ações certasConcebido para

comunicar

53

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

NCC

Separate Gateway/RTUCOM 500, COM 610,

COM 581 or RTU 560

IEC 61850-8-1

TCP/IP

Operators workstationMicroSCADA Pro

SYS 600 (with GW)

Remote SMS workplacewith PCM 600

Remote Binaryand Analog

communication

Optional SPA/LON

IEC 870-5-103

IEC 61850 Made in ABB

54

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

MicroSCADA Pro com gráficos novos

55

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Exemplo de solução de ABB

56

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IED 670 Opções para comunicação

57

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IED 670 Opções para controle

58

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Interação rápida, simples e única através de IHM com múltiplas páginas, rápida conexão PC Ethernet no frontal & LAN TCP/IP com

Pronto a uso e entrega rápida de produtoscom ajustes simples e ferramenta de matrizde sinalUma ferramenta comum para proteção e controle (PCM 600) e um MicroSCADA Pro UM IED para aprender, UM IED paraaplicar, UM IED para operar, UM IED paramanter

Simples selecionar, ajustar, operar e manter através de IEDs pré-configurados com IHM e avançada ferramenta PCM

Amigável

IED 670 é projetado para VOCÊ

59

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IHM local e acesso de PC local ou remoto

60

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Protection & Control IED Manager PCM 600

Gerente de projeto

Configuração de aplicações (CAP)

SCL file Exportação e importação

Ajustes 6 grupos (PST)

Matriz de sinais (SMT)

Editor de display gráfico 6 paginas (GDE)

Registrador de perturbação (DH)

Task Scheduler (Scheduler)

Monitorando de valores (MON)

Leitura de eventos (EV)

61

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Protection & Control IED Manager PCM 600

62

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Protection & Control IED Manager PCM 600

63

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

PCM 600 Disturbance Handling ToolRecordings List

Report Tool

Open recordings for evaluation

Recording management

Manual trig of IED

Read from IED

Import/Export in COMTRADE format

Delete

Recordings List layout

Default template

e-mail-list

Template Editor

64

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

REL670 – Line/Cable1 ou 2 disjuntores – 1 ou 3- fasico

RED670 – Multi terminal1 ou 2 disjuntores – 1 ou 3- fasico

3 ou 5 finais de linha

RET670 – Transformer2 enrolamentos - 1 ou 2 disj/e

3 enrolamentos – 1 ou 2 disj/e

REC670 – Bay 1 ou 2 disjuntores

Disjuntor 1 ½

REB670 - Bus3-fasico para 8 bays

3 x 1-fasico para 24 bays

Somatório para 24 bays

IED 670 pré-configuado para transmissão

65

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Um conceito sem igual com um IED, Uma biblioteca, uma ferramenta comum, uma MicroSCADA Pro, completamente desenvolvida para 61850 padrão aberto,

Desenvolvido para 61850 desde o começo. Não é um depois que pensamento.Biblioteca de função de aplicação sem igual independente de hardware e traçou em IEC 61850 Caminho de migrartion claro para IEDs e MicroSCADA Pro com SPA, LON, IEC 60850-5-103, OPC, TCP/IP

Acrescenta valor a seu investimento durante o ciclo de vida total

Eternamente jovem

Sempre “Esado da arte” IED “Made in ABB”

66

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Comparação entre protocolos de comunicação

67

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Certicate de KEMA e interoperabilidade

68

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

ABB Centro de verificação de sistema

69

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

LON

TCP/IP

Optional SPAIEC 870-5-103

Migração com LON “Made in ABB”

70

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IEC 61850-8-1

TCP/IP

Optional SPA/LONIEC 870-5-103

Migração para IEC 61850 “Made in ABB”

71

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IEC 61850-8-1

TCP/IP

Optional SPA/LONIEC 870-5-103

Interoperabilidade “Made in ABB”

Third party IED

Other protocol (IEC 870-5-103, DNP 3.0 etc.)

Omicron test planwith Goose

72

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IED 670 Entregas e Teste de Aceitação de fábrica

Brasil: IED 670, MicroSCADA Pro e LON India: IED 670, MicroSCADA Pro e IEC 61850

73

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

IED 670 Entregas e Teste de Aceitação de fábricaNoruega RED 670 Finlândia REB 670 FAT

Jordal

RED670

Matre

Seim

Padöy

RED670

RED670 Internet

40 km 30 km

30 km

74

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

Duas medalhas de ouro para 670

75

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén

ABB Referências selecionadas para IEC 61850

76

©A

BB

Pow

er T

echn

olog

ies

AB

2006-04-20 Carl Öhlén