Vert-X 31E - 24V / SSI
Applications• Concretepump• E-Motorfeedbacksystem• Forklift
Features• HighprotectionclassIP68• Compactdimensions• Veryfast,non-contacting measuringmethod• Verylonglife• Applicationsunderadverse ambientconditionspossible (humidity,dampness,dust, vibrationsetc.)•Lowtemperaturecoefficientof theoutputsignal
Sensor principle MH-X2
Electrical data
Measuringrange ° 0...360
Indep.linearity(withoutmisalignment) % ±0.5
Indep.linearity(withallowedmisalignment@360°) % ±1
Max.hysteresis ° 0.5
Resolution bit 12
Max.repeatability ° 0.35
Max.temperaturecoefficientoftheoutputsignal ppm/°K 5
Powersupplyvoltage VDC 8...35
Reversepolarityprotectionofpowersupply yes
Redundancyfeasible no
Output driver TTL
MTTFd/MTBF years 536/536
Currentconsumptionwithoutload(typ.) mA 20
Recomendedohmicloadatoutput kOhm 1
Max.capacitiveloadatoutput nF -
Electricalconnection Cable4pole
Crosssectionofsinglewires mm2 0.35(AWG22)
Output driver Differential RS-485
MTTFd/MTBF years 501/501
Currentconsumptionwithoutload(typ.) mA 60
Recomendedohmicloadatoutput kOhm 0.12
Max.capacitiveloadatoutput nF -
Electricalconnection Cable6pole
Crosssectionofsinglewires mm2 0.25(AWG24)
Mechanical data
Mechanicalangle ° 360(continuous)
Protectionclass IP68
Min.life movements nolimitation
Operating&storagetemperature °C -40...+85
IEC68-2-6Vibration(Amax=0.75mm,f=5…2000Hz) g 50
IEC68-2-27Shock g 200
Standards
EN55022classB,Emissionradiated(30...230MHz) dB(µV/m) max.30
EN55022classB,Emissionradiated(230...1000MHz) dB(µV/m) max.37
EN61000-4-2,ESD(contactdischarge/airdischarge) kV ±4/±8
EN61000-4-3,ImmissionHFradiated(80...1000MHz) V/m 30
EN61000-4-4,Burst(onalllines) kV ±1
EN61000-4-5,Surge(linestoground) kV ±1
EN61000-4-6,ImmissionHFconducted(0.15...80MHz) Vemk 10
EN61000-4-8,Immissionmagneticfield(50Hz) A/m 300
IEC60393-1Insulationresistance(500VDC,1bar,2s) GOhm 20
IEC60393-1Dielectricstrength(VAC,50Hz,1min,1bar) kV 1
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 12.07.17
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
Vert-X 31E - 24V / SSIOrdering code
Vert-X 3 1 E 5 6 3 6 1 6 1 8 0 2
Electrical angle36 Standard Electricalangle360°
Sensor principle 6 MH-X2
Mechanical version31E5 Standard Magneticactuatortype531E6 Standard Magneticactuatortype631E7 Optional Magneticacutatortype731E9 Optional Specialmagneticactuator
Output characteristics / Output driver TTL Standard 1 DifferentialRS-485 Optional 3
Output signal SSI Standard 6
Power supply voltage 24VDC Standard 1
MH-X2
Custommagneticactuator X
Customcable X
Electrical connection 6 Optional Cable6pole8 Standard Cable4pole9 Optional Specialcable
Length of cable02 Standard 1.0m06 Optional 3.0m10 Optional 5.0m99 Optional Speciallength
Options (onrequest)
Mounting holea Standard Through-holeø4.4mmb Optional Through-holeø4.4mmwithcounterboreø7.4mm
a
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 12.07.17
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
Vert-X 31E5axxx xxx xxx
Accessoires (incl.)• None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorseemountinginformation
Vert-X 31E5bxxx xxx xxx
Accessoires (incl.)• None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorseemountinginformation
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 12.07.17
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
Vert-X 31E6axxx xxx xxx
Accessoires (incl.)• None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorseemountinginformation
Vert-X 31E6bxxx xxx xxx
Accessoires (incl.)• None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorseemountinginformation
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 12.07.17
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
Vert-X 31E7axxx xxx xxx
Accessoires (incl.)• None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorseemountinginformation
Vert-X 31E7bxxx xxx xxx
Accessoires (incl.)• None
Working position (Z) and max. permitted misalign-ment of the magneticactuatorseemountinginformation
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 12.07.17
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
Vert-X 31E5
Mounting information
Working position (Z)MH-X2 16.10mmMax. permitted misalign-ment of the magneticactuatordx ±0.50mmdy ±0.50mmdz ±0.30mm
Vert-X 31E6
Mounting information
Working position (Z)MH-X2 8.70mmMax. permitted misalign-ment of the magneticactuatordx ±0.50mmdy ±0.50mmdz ±0.50mm
A company of the Siedle-Group
Errors and omissions excepted. Subject to change without notice. / State: 12.07.17
Contelec AGPortstrasse 38CH-2503 Biel/BiennePhone +41 (0)32 3665600Telefax +41 (0)32 [email protected]
Vert-X 31E7
Mounting information
Working position (Z)MH-X2 13.00mm
Max. permitted misalign-ment of the magneticactuatordx ±1.00mmdy ±1.00mmdz ±0.80mm