VertiCool Aurora Engineering Guide Effective September 2017 Air-Cooled, Water-Cooled and Water Source Heat Pump

VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

  • Upload
    vudien

  • View
    233

  • Download
    7

Embed Size (px)

Citation preview

Page 1: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

VertiCool AuroraEngineering GuideEffective September 2017

Air-Cooled, Water-Cooledand Water Source Heat Pump

Page 2: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

2Subject to change without notice. 20.20-TD (0917)

ContentsProduct Features ��������������������������������������������������������������������������������������������������� 3Options ������������������������������������������������������������������������������������������������������������������ 4Physical Data������������������������������������������������������������������������������������������������������5-6Air-Cooled Performance Data (a) (b) (c) ������������������������������������������������������������7-8Water-Cooled Performance Data (a) (c) (d) (e) ������������������������������������������������9-10Water Source Heat Pump Performance Data (a) (c) (d) (e) �������������������������������� 11Blower Performance Data (a) (b) (c) ��������������������������������������������������������������12-13

Evaporator: �����������������������������������������������������������������������������������������������12-13Blower Performance Data (a) �������������������������������������������������������������������������14-15

Condenser: �����������������������������������������������������������������������������������������������14-15Hot Water Coil Performance Data (a) (b) (c) (d) (e) (f) ���������������������������������������� 16Chilled Water Coil Performance Data (a) (b) (c) (d) (e) (f) ���������������������������������� 17Steam Coil Performance Data (a) (b) (c) (d) ������������������������������������������������������� 18Electrica Data (Cooling Only): ������������������������������������������������������������������������19-20Electrica Data (Cooling with Electric Heat): ����������������������������������������������������21-22Electrica Data ������������������������������������������������������������������������������������������������������ 23

Compressor RLA Electrical Data: ������������������������������������������������������������������ 23Evaporator Motor FLA: ���������������������������������������������������������������������������������� 23

Electrica Data ������������������������������������������������������������������������������������������������������ 24Condenser Motor FLA: ���������������������������������������������������������������������������������� 24Electric Heat FLA: �������������������������������������������������������������������������������� 24

Electrica Data (Air-Cooled (c) (d): ����������������������������������������������������������������������� 25Electrica Data (Air-Cooled (c) (d) (e) ��������������������������������������������������������������26-27Electrica Data (Air-Cooled (c) (d) �������������������������������������������������������������������28-30Electrica Data (Water-Cooled (c) (d) ������������������������������������������������������������������� 31Electrica Data (Water-Cooled (c) (d) (e) ���������������������������������������������������������32-33Electrica Data (Water-Cooled (c) (d) ��������������������������������������������������������������34-36Basic Model Configurations ��������������������������������������������������������������������������������� 37Unit Dimensions �������������������������������������������������������������������������������������������������� 38Cabinet Configurations and Unit Drawings�����������������������������������������������������39-41Service Clearance (Plan View) ���������������������������������������������������������������������������� 42Application Data �������������������������������������������������������������������������������������������������� 43Resources ����������������������������������������������������������������������������������������������������������� 44Basic Model Designation ������������������������������������������������������������������������������������� 45

Page 3: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

3Subject to change without notice. 20.20-TD (0917)

• Air-Cooled, Water-Cooled or Water Source Heat Pump Configurations• R-410A Refrigerant, Factory Charged• 12 thru 35 Ton Units are Splittable using Resealable Refrigerant Fittings• Fits through 32” doorways ( 3 - 15 Ton Cabinets)• ½” Fiberglass Lined Cabinet (Thermal/Acoustical, min� density of 2 Pounds)• Access panels without use of tools• Rugged cabinet construction• Duct Flanges Factory Installed• Drain Connections on Both Evaporator and Condensing Sections• 304 Stainless Steel “V” Style Drain Pan in Evaporator Section• �25” ESP Capability (1” ESP Option for Evaporator and Condensing Sections)• Belt Driven Blowers (Evaporator and Condensing Sections)• Pillow Block Bearings ( 12 & 15 Ton Condensers, 20 - 35 Ton Evaporators)• Ball Bearing Motors• Premium Efficiency Motors (1 HP & Above)• Resiliently Mounted Ball Bearings for Blowers• Cast Iron Pulleys and Sheaves• Variable Pitch Motor Sheaves• All shafts, sheaves & pulleys keyed• Adjustable Motor Mounts in Evaporator and Condensing Sections• High (Manual Reset) and Low (Auto Reset) Refrigerant Pressure Safety Switches• Loss of Air Safety Switch (when electric heat used)• Scroll Compressors• Adjustable Expansion Valve with External Equalizer (MOP Type)• Sight Glass / Moisture Indicators Visible From Cabinet Exterior• Filter Driers• Accessibility to High and Low Side Schrader Access Fittings for Refrigerant Pressures While Unit Is Operational• Draw Through Air Flow Configuration• Interlaced Evaporator Coils• Single Electrical Control Box• 24 Volt Control Circuits• Transformer with Built In Circuit Breaker• Individual Contactor for each Stage of Electric Heat• Individual Contactor for each Motor and Compressor• Co-axial Counter Flow Heat Exchanger(s) on Water-Cooled Units• Limited Warranty 1 Year on Parts and 5 Years on Compressors• Functionally Run Tested at the Factory

Product Features

The VertiCool Aurora Series of units are splittable, self-contained, floor mounted, single package units. They are available as air-cooled, water-cooled or as water source heat pump configurations. The units offer a variety of evaporator air flow patterns for application flexibility. Additionally, the units are available as standard configurations or they can be tailored for a specific application as a made-to-order unit. Individual sections can be utilized with other product series.

Page 4: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

4Subject to change without notice. 20.20-TD (0917)

CONTACT THE FACTORY FOR OTHER OPTIONAL FEATURES.

Options

(Items in BOLD are factory installed): • Powder Coated Cabinet• Plenum w/ Discharge Grilles or Duct Flange• Condensate Pump• Electric Heat (Second Control Box Required, 55 kW & Over)• Protective Coil Coatings• SCR Controllers• Air or Water Side Economizer• Hot Water, Chilled Water and Steam Coils• Variable Frequency Drive (Evaporator)• Drain Pan Overflow Switch• Head Pressure Control Valves• Double Wall Construction (Solid or Perforated) or Acoustic Foam Package• Hot Gas Bypass (Standard or Modulating)• Low Ambient Operation (VFD or Flooded Condenser)• Freezestat• Non-Fused Disconnects• Thermostats• Marvel Microprocessor Controls• Upgraded Motors / Drive Sets• Compressor Anti-Short Cycle Timer• Quench Valve w/ Suction Accumulator• Suction Line Accumulator• Oil Separator• Liquid Receivers• Hot Gas Reheat• Condenser Filter Box• Return Air Grilles• Chilled Water and Hot Water Valves• Smoke Detectors• Firestats• Dry Contacts

Page 5: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

5Subject to change without notice. 20.20-TD (0917)

Tons 3 4 5 6 8 10Evaporator Supply Air CFM 1200 1600 2000 2400 3200 4000

Evaporator BlowerSize 12-12 15-15Qty 1

Evaporator Motors (a)Std. HP @ .25" ESP 1/3 1/2 3/4 1-1/2Opt. HP @ 1.0" ESP 1/2 3/4 1 1-1/2 2

Evaporator CoilRows 3Face Area 4.67 9.33FPI 12

Filter

Type Pleated ThrowawayQty 2 4Dimensions 14 x 25 x 2Efficiency MERV 8

Compressor Type ScrollQty 1 2

Condenser Air CFM 1800 2400 3000 3600 4800 6000

Condenser BlowerSize 12-12 15-15Qty 1

Condenser Motors (a)Std. HP @ .25" ESP 1/3 3/4 1 3/4 1-1/2 3Opt. HP @ 1.0" ESP 3/4 1 1-1/2 3 5

Condenser CoilRows 4Face Area 5.33 10.67FPI 16

Water Cooled Cond. (e)Type Co-AxialQty 1 2

Charge R-410A (Lbs-Ozs)(Charge per circuit) (f)

Air-Cooled 4 - 7 4 - 15 4 - 11 4 - 5 4 - 13 4 - 10Water-Cooled 1 - 14 2 - 8 1 - 14 2 - 8Water Source HP 2 - 7 2 - 13 2 - 5 2 - 11 2 - 12

Weight (Net Operating) (b)Air-Cooled 800 1150Water-Cooled 700 1000Water Source HP 750 1075

Available Voltages (e)208/230-1-60 • • • - - - - - - - - -208/230-3-60 • • • • • •460-3-60 • • • • • •

(a) Certain options may affect motor size� Run unit in UCA Select for proper motor HP�(b) Net operating weight is for basic unit only� Options will add weight�(c) Pulley & Belt upgrade only�(d) 575 volt available� Consult factory�(e) Contact factory for geothermal applications�(f) R-410A Refrigerant charge is for base unit configuration. Addition of some options may alter refrigerant amount.

Physical Data

Page 6: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

6Subject to change without notice. 20.20-TD (0917)

(a) Certain options may affect motor size� Run unit in UCA Select for proper motor HP�(b) Net operating weight is for basic unit only� Options will add weight�(c) Pulley & belt upgrade only�(d) 575 volt available� Contact factory�(e) Contact factory for geothermal applications�(f) R-410A Refrigerant charge is base unit configuration. Addition of some options may alter refrigerant amount.(g) Units always shipped split�

Tons 12 15 20 25 30 (g) 35 (g)Evaporator Supply Air CFM 4800 6000 8000 10,000 12,000 14,000

Evaporator Blower Size 15-15 15-11 18-13Qty 1 2

Evaporator Motors (a) Std. HP @ .25" ESP 1-1/2 3 5 7-1/2Opt. HP @ 1.0" ESP 3 5 7-1/2 10

Evaporator CoilRows 3 4 Face Area 14 20.83 23.89 27.78FPI 12 14

Filter

Type Pleated ThrowawayQty 6 12 8Dimensions 14 x 25 x 2 12 x 20 x 2 20 x 15 x 2 20 x 25 x 2Efficiency MERV 8

Compressor Type ScrollQty 2

Condenser Air CFM 7200 9000 12000 15000 18000 21000

Condenser Blower Size 15-11 18-3Qty 2 3

Condenser Motors (a) Std. HP @ .25" ESP 3 5 7-1/2 15Opt. HP @ 1.0" ESP 5 5 (c) 7-1/2 10 15

Condenser CoilRows 4 6 Face Area 16 20.83 23.89 27.78FPI 16

Water Cooled Cond. (f) Type Co-AxialQty 2 4

Charge R-410A (Lbs-Ozs)(Charge per circuit) (f)

Air-Cooled 9-1 9-4 25-5 25-0 29-1 32-7Water-Cooled 3-15 4-9 9-12 9-14 12-6 13-7Water Source HP 5-0 5-7 13-0 16-11 18-9

Weight (Net Operating) (b)Air-Cooled 1600 2650 4000 4100Water-Cooled 1150 1730 2750 2800Water Source HP 1250 2000 3050 3100

Available Voltages (e)208/230-1-60 - - - - - - - - - - - - - - - - - -208/230-3-60 • • • • • •460-3-60 • • • • • •

Physical Data

Page 7: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

7Subject to change without notice. 20.20-TD (0917)

SINGLE

Model Number CFMEntering Air Temp. (°F)

Entering Air Temperature (°F) 75 95 115

DB WB Total Sensible Total Sensible Total Sensible

VA3G*ASHA 1200

86 72 44500 29600 39800 28100 35400 2650080 67 40700 28900 36700 27300 32700 2550075 62.5 37800 28700 34100 27000 30200 2510072 60 36300 28300 32700 26600 28800 24600

VA4G*ASHA 1600

86 72 55300 37100 50400 35400 45800 3340080 67 51600 36600 46700 34700 41900 3260075 62.5 48100 36500 43700 34400 39000 3230072 60 46200 36000 42000 33900 37600 31800

VA5G*ASHA 2000

86 72 71400 47600 65400 45500 59000 4290080 67 66000 47000 60400 44600 54500 4180075 62.5 61300 46500 56000 44000 50400 4120072 60 58800 45600 53600 43200 48200 40500

DUAL

VA6G*AHA 2400

86 72 88500 59200 79800 55600 68900 5210080 67 80900 57700 73300 54300 64900 5070075 62.5 74900 57100 67600 53800 60400 4980072 60 71900 56200 64500 52800 57500 48500

VA8G*AHA 3200

86 72 112400 76400 101100 74000 90300 6990080 67 103900 74900 94100 71400 84000 6710075 62.5 96700 74800 87800 70800 78200 6670072 60 92800 73800 84400 69500 75100 65600

VA10G*AHA 4000

86 72 140400 92800 126900 87400 113200 8160080 67 129100 90700 117800 85700 105300 8010075 62.5 120400 90100 109800 84900 97600 7890072 60 115900 89000 105400 83600 93000 77300

(a) Capacities are gross values, not adjusted for motor heat�(b) Some refrigerant circuit components may impact on unit capacities�(c) Applications with ambient conditions 75° F and lower may require additional refrigerant circuit components�

Consult factory for details�

Air-Cooled Performance Data (a) (b) (c)

Page 8: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

8Subject to change without notice. 20.20-TD (0917)

DUAL

Tons CFMEntering Air Temp. (°F)

Entering Air Temperature (°F) 75 95 115

DB WB Total Sensible Total Sensible Total Sensible

VA12G*AHA 4800

86 72 171000 118400 159800 112500 141900 10560080 67 161400 115700 147400 110000 131100 10360075 62.5 151400 115100 136800 108900 122500 10230072 60 145700 113700 131100 107000 118100 100100

VA15G*AHA 6000

86 72 216800 144900 197800 140400 176800 13270080 67 200700 144700 183300 137300 164500 12850075 62.5 187200 144600 170700 136000 153200 12740072 60 180100 142600 163900 133800 146900 125900

VA20G*AHA 8000

86 72 330300 222400 299900 211200 266400 19870080 67 306500 217200 277500 206000 246800 19340075 62.5 286000 215900 257700 203600 228600 19000072 60 275200 213500 247100 200200 218700 185500

VA25G*AHA 10000

86 72 373200 255900 339300 240300 305900 22610080 67 350900 250600 319600 237100 287100 22270075 62.5 325200 247300 296400 234000 265600 21820072 60 312000 243900 284700 230400 255100 213500

VA30G*AHA 12000

86 72 424500 299500 385500 284900 348400 26960080 67 399300 293800 361500 278000 324700 26150075 62.5 372000 291200 337000 274700 302600 25730072 60 356800 286900 324200 270300 291700 252800

VA35G*AHA 14000

86 72 515600 348200 473600 332900 424300 31760080 67 477500 344000 437300 325500 393500 30460075 62.5 445300 339600 406900 321500 367800 29940072 60 428000 332600 390300 316300 353400 295200

(a) Capacities are gross values, not adjusted for motor heat�(b) Some refrigerant circuit components may impact on unit capacities�(c) Applications with ambient conditions 75° F and lower may require additional refrigerant circuit components�

Consult factory for details�

Air-Cooled Performance Data (a) (b) (c)

Page 9: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

9Subject to change without notice. 20.20-TD (0917)

SINGLE

Tons GPMPD

(psi)(b)

CFMEntering Air Entering Water Temperature (°F) Temp. (°F) 80 85 90

DB WB Total Sensible Total Sensible Total Sensible

VW3G*ASHA 9 4.4 1200

86 72 43800 29600 42800 29200 41800 2880080 67 40300 29000 39400 28500 38400 2810075 62.5 37400 28700 36500 28200 35700 2780072 60 35800 28200 35000 27800 34200 27300

VW4G*ASHA 12 6.7 1600

86 72 56400 38300 54800 37800 53300 3720080 67 52100 37200 50800 36700 49400 3610075 62.5 48500 36700 47200 36100 46000 3560072 60 46500 36100 45300 35500 44200 34900

VW5G*ASHA 15 4.6 2000

86 72 70400 47100 68700 46400 66900 4570080 67 65000 45800 63400 45100 61800 4440075 62.5 60400 45400 58900 44600 57400 4390072 60 58000 44700 56600 44000 55100 43200

DUAL

VW6G*AHA 18 4.4 2400

86 72 87300 59700 85300 58900 83300 5800080 67 80800 57700 78900 56900 77000 5600075 62.5 74700 56900 73000 56000 71300 5520072 60 71400 56000 69700 55100 68000 54200

VW8G*AHA 24 6.7 3200

86 72 115300 77500 112400 76300 109500 7510080 67 106200 74900 103700 73700 101000 7250075 62.5 98100 74200 95700 72900 93300 7170072 60 93600 73300 91300 72100 89000 70800

VW10G*AHA 30 4.6 4000

86 72 141900 94000 138100 92600 134400 9120080 67 131300 92100 127900 90700 124500 8930075 62.5 122000 91200 118900 89700 115900 8830072 60 117000 89600 114100 88200 111100 86700

(a) Capacities are gross values, not adjusted for motor heat�(b) Pressure drop is for heat exchanger only and does not include piping, valves, fittings, etc.(c) Some refrigerant circuit components may impact on unit capacities�(d) Applications with water conditions 75° F and lower may require additional refrigerant circuit components�

Consult factory for details�(e) Contact factory for geothermal applications�

Water-Cooled Performance Data (a) (c) (d) (e)

Page 10: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

10Subject to change without notice. 20.20-TD (0917)

DUAL

Tons GPMPD

(psi)(b)

CFMEntering Air Entering Water Temperature (°F) Temp. (°F) 80 85 90

DB WB Total Sensible Total Sensible Total Sensible

VW12G*AHA 36 7.7 4800

86 72 175400 122000 171200 120500 166600 11890080 67 161600 117000 157200 115300 153000 11360075 62.5 150600 115300 146600 113500 142600 11170072 60 145200 113800 141400 111900 137500 110100

VW15G*AHA 45 7.1 6000

86 72 223600 150000 218600 147900 213500 14570080 67 202700 144900 198100 142800 193400 14070075 62.5 187600 143200 183400 141100 179100 13900072 60 180500 141400 176400 139300 172400 137200

VW20G*AHA 60 4.6 8000

86 72 332600 216200 324100 212700 313300 21350080 67 307200 216100 299500 212500 291700 20890075 62.5 286100 214400 279000 210800 271800 20710072 60 274500 211500 267600 207800 260700 204000

VW25G*AHA 75 8.2 10000

86 72 374200 257000 365300 253200 356200 24950080 67 349700 251500 341400 247700 332900 24380075 62.5 327700 249500 319900 245700 311900 24180072 60 315600 246100 308100 242300 300400 238300

VW30G*AHA 90 7.1 12000

86 72 426800 297400 417500 293500 407900 28950080 67 398300 291700 389600 287600 380700 28340075 62.5 373300 289600 365100 285300 356700 28090072 60 359600 285400 351700 281000 343500 276400

VW35G*AHA 105 3.8 14000

86 72 501100 348700 491000 344200 480100 33960080 67 467200 342000 457800 337400 447900 33270075 62.5 434100 338100 425400 333400 416100 32850072 60 414700 331600 406400 326900 397500 322000

(a) Capacities are gross values, not adjusted for motor heat�(b) Pressure drop is for heat exchanger only and does not include piping, valves, fittings, etc.(c) Some refrigerant circuit components may impact on unit capacities�(d) Applications with water conditions 75° F and lower may require additional refrigerant circuit components�

Consult factory for details�(e) Contact factory for geothermal applications�

Water-Cooled Performance Data (a) (c) (d) (e)

Page 11: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

11Subject to change without notice. 20.20-TD (0917)

Tons GPM PD (psi) (b) CFMEntering Air Temp. (°F) Heating

CapacityDB

3 9 4.4 120070 4480060 45900

4 12 6.7 160070 5950060 61000

5 15 4.6 200070 7490060 76600

6 18 4.4 240070 8940060 91600

8 24 6.7 320070 11900060 121900

10 30 4.6 400070 14960060 153100

12 36 7.7 480070 17400060 178300

15 45 7.1 600070 22500060 230500

20 60 4.6 800070 33090060 338900

25 75 8.2 1000070 37470060 381700

30 90 7.1 1200070 42780060 436400

35 105 3.8 1400070 52060060 533500

(a) Capacities are gross values, not adjusted for motor heat�(b) Pressure drop is for heat exchanger only and does not include piping, valves, fittings, etc.(c) Some refrigerant circuit components may impact on unit capacities�(d) Values at 70° F Entering Water Temperature�(e) Contact factory for geothermal applications�

Water Source Heat Pump Performance Data (a) (c) (d) (e)

Page 12: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

12Subject to change without notice. 20.20-TD (0917)

(a) Can interpolate between values, but do not extrapolate outside values� Contact factory for values outside the data�(b) Blower performance of basic unit with 2”, MERV 8 pleated throwaway filter and wet coil 80 / 67 / 95 and “A” air path.(c) Performance with nominal CFM. For other CFM or ESP, use the UCA Select software or contact the factory for your specific

application�

Evaporator:

Tons CFMExternal Static Pressure (ESP) Max.

0.25” 0.50” 0.75” 1.0” 1.25” 1.50” HP ESP

3 1200 RPM 544 685 805 908 995 1068

1.5 2.00” BHP 0.14 0.23 0.33 0.45 0.58 0.72HP 0.33 0.33 0.5 0.75 0.75 1

4 1600RPM 616 739 848 947 1037 1120

1.5 2.00” BHP 0.24 0.34 0.46 0.58 0.72 0.87HP 0.33 0.5 0.75 0.75 1 1.5

5 2000RPM 698 806 903 994 1078 1157

1.5 1.50”BHP 0.39 0.51 0.64 0.78 0.92 1.08HP 0.5 0.75 1 1 1.5 1.5

6 2400RPM 445 557 655 740 816 884

1.5 1.50”BHP 0.29 0.43 0.60 0.80 1.01 1.23HP 0.5 0.75 0.75 1 1.5 1.5

8 3200RPM 508 601 688 767 841 909

3 2.00”BHP 0.54 0.71 0.89 1.10 1.32 1.57HP 0.75 1 1.5 1.5 2 2

10 4000RPM 587 665 739 810 877 941

3 1.75”BHP 0.95 1.14 1.34 1.56 1.80 2.06HP 1.5 1.5 2 2 3 3

Blower Performance Data (a) (b) (c)

Page 13: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

13Subject to change without notice. 20.20-TD (0917)

(a) Can interpolate between values, but do not extrapolate outside values� Contact factory for values outside the data�(b) Blower performance of basic unit with 2”, MERV 8 pleated throwaway filter and wet coil 80 / 67 / 95 and “A” air path.(c) Performance with nominal CFM. For other CFM or ESP, use the UCA Select software or contact the factory for your specific

application�

Evaporator:

Tons CFMExternal Static Pressure (ESP) Max.

0.25” 0.50” 0.75” 1.0” 1.25” 1.50” HP ESP

12 4800RPM 614 682 748 812 874 933

5 2.00”BHP 1.35 1.56 1.78 2.01 2.26 2.52HP 2 2 3 3 3 5

15 6000RPM 732 787 841 895 947 998

5 1.75”BHP 2.48 2.74 3.00 3.27 3.55 3.84HP 3 5 5 5 5 5

20 8000 RPM 613 679 741 801 859 914

7.5 1.50” BHP 2.29 2.65 3.01 3.39 3.78 4.17HP 3 5 5 5 5 7.5

25 10000RPM 724 779 832 883 933 981

10 2.00”BHP 4.13 4.57 5.02 5.48 5.94 6.41HP 5 7.5 7.5 7.5 7.5 10

30 12000RPM 799 847 893 939 983 1026

15 2.00”BHP 6.35 6.89 7.42 7.95 8.49 9.04HP 10 10 10 10 15 15

35 14000RPM 639 686 732 777 821 864

15 2.00”BHP 5.54 6.10 6.69 7.31 7.94 8.60HP 7.5 7.5 10 10 10 15

Blower Performance Data (a) (b) (c)

Page 14: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

14Subject to change without notice. 20.20-TD (0917)

(a) Can interpolate between values, but do not extrapolate outside values� Contact factory for values outside the data�

Condenser

Tons CFMExternal Static Pressure (ESP) Max.

0.25” 0.50” 0.75” 1.0” 1.25” 1.50” HP ESP

3 1800 RPM 592 714 823 922 1012 1097

1.5 2.00”BHP 0.26 0.36 0.48 0.60 0.74 0.89HP 0.33 0.5 0.75 0.75 1 1.5

4 2400RPM 696 798 891 979 1060 1137

2 2.00”BHP 0.50 0.62 0.76 0.90 1.05 1.21HP 0.75 0.75 1 1.5 1.5 1.5

5 3000RPM 809 896 977 1054 1127 1197

3 2.00”BHP 0.88 1.02 1.18 1.34 1.51 1.69HP 1.5 1.5 1.5 2 2 3

6 3600RPM 503 590 673 750 823 891

3 2.00”BHP 0.64 0.81 0.99 1.20 1.42 1.66HP 1 1 1.5 1.5 2 2

8 4800RPM 607 676 742 806 868 928

5 2.00”BHP 1.33 1.54 1.76 1.99 2.24 2.49HP 2 2 3 3 3 3

10 6000RPM 720 776 830 884 937 988

5 1.75”BHP 2.43 2.68 2.94 3.21 3.49 3.78HP 3 5 5 5 5 5

Blower Performance Data (a)

Page 15: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

15Subject to change without notice. 20.20-TD (0917)

(a) Can interpolate between values, but do not extrapolate outside values� Contact factory for values outside the data�

Condenser

Tons CFMExternal Static Pressure (ESP) Max.

0.25” 0.50” 0.75” 1.0” 1.25” 1.50” HP ESP

12 7200RPM 598 669 735 798

5 1.00”BHP 1.87 2.20 2.54 2.89HP 3 3 5 5

15 9000RPM 702 761 817 871 923 974

7.5 1.75”BHP 3.34 3.75 4.16 4.58 5.01 5.44HP 5 5 5 7.5 7.5 7.5

20 12000RPM 674 737 797 855 910

7.5 1.25”BHP 3.93 4.48 5.04 5.62 6.21HP 5 7.5 7.5 7.5 7.5

25 15000RPM 793 846 897 946 994 1040

15 2.00”BHP 7.04 7.72 8.41 9.10 9.81 10.53HP 10 10 15 15 15 15

30 18000RPM 674 724 774 822

15 1.00”BHP 7.02 7.85 8.72 9.62HP 10 10 15 15

35 21000RPM 704 750 794 838 880 922

20 1.75”BHP 9.49 10.39 11.32 12.29 13.29 14.32HP 15 15 15 15 20 20

Blower Performance Data (a)

Page 16: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

16Subject to change without notice. 20.20-TD (0917)

Tons CFM GPM PD Ft. H2O Capacity (Btuh)3 1200 4.2 9.7 406404 1600 4.8 6.3 477305 2000 5.4 7.8 539406 2400 8.3 6.7 812308 3200 9.7 5.4 9563010 4000 11.0 6.8 10824012 4800 14.3 3.4 13913015 6000 16.0 4.2 15700020 8000 25.4 4.1 24860025 10000 28.5 3.1 28030030 12000 33.7 4.2 33112035 14000 39.8 3.7 389830

(a) Hot Water Coil Valves are optional� (b) Valves are spring return, On / Off operation only�(c) Entering water at 180° F� Leaving water at approximately 160° F�(d) Entering air temperature 65° F�(e) For other operating conditions or fluid type, contact the factory for performance.(f) Hot Water Coil Valve Sizes:

Tons Valve Size3 3/4”4 3/4”5 3/4”6 1”8 1”10 1-1/4”12 1-1/4”15 1-1/4”20 1-1/2”25 1-1/2”30 1-1/2”35 1-1/2”

Hot Water Coil Performance Data (a) (b) (c) (d) (e) (f)

Page 17: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

17Subject to change without notice. 20.20-TD (0917)

(a) Capacity based on 80° F DB / 67° F WB with 45° F EFT�(b) Chilled water entering at 45° F�(c) For other operating conditions or fluid type, contact the factory for performance.(d) Chilled Water Coil Valves are optional� (e) Valves are spring return, On / Off operation only�(f) Chilled Water Coil Valve Sizes:

Tons CFM GPM PD Ft. H2O Total (MBH) Sensible (MBH)3 1200 8.2 4.6 41000 304004 1600 10.0 6.6 50300 383005 2000 12.0 9.2 59200 458006 2400 14.2 2.5 72000 553008 3200 18.0 3.9 88700 6940010 4000 20.0 4.7 100800 8130012 4800 28.8 1.6 145500 11190015 6000 35.0 2.3 172400 13430020 8000 50.0 4.1 253500 19210025 10000 60.0 5.7 298200 23000030 12000 72.0 6.3 359200 27840035 14000 83.0 6.1 413500 314700

Chilled Water Coil Performance Data (a) (b) (c) (d) (e) (f)

Tons Valve Size3 3/4”4 3/4”5 3/4”6 1”8 1”10 1-1/4”12 1-1/4”15 1-1/4”20 1-1/2”25 1-1/2”30 1-1/2”35 1-1/2”

Page 18: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

18Subject to change without notice. 20.20-TD (0917)

Tons CFM2 psi

Capacity (MBH) Condensate (lb. / hr.) LAT3 1200 72200 74.8 120.24 1600 84100 87.1 113.35 2000 94300 97.7 108.36 2400 154700 160.2 124.28 3200 181000 187.4 116.910 4000 203500 210.7 111.712 4800 279400 289.3 118.415 6000 314500 325.6 113.120 8000 414900 429.6 112.625 10000 464800 481.2 107.630 12000 575900 596.2 109.035 14000 663300 686.6 108.5

(a) Low pressure, less than 10 psig�(b) Entering air at 65° F�(c) For other operating pressures, air flows and entering air conditions contact factory.(d) Steam valves and components by others, field installed.

Steam Coil Performance Data (a) (b) (c) (d)

Page 19: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

19Subject to change without notice. 20.20-TD (0917)

The following sections provides the formulas and the data to calculate the Minimum Circuit Ampacity (MCA) and the Maximum Fuse Size (MOP) for your specific unit configuration. Please note that the UCA Select software can also be used to calculate the electrical data for the VertiCool Aurora units�There are a variety of unit configurations. Please make sure to use the correct formulas per your configuration.It must be noted that the formulas refer to the largest motor amps� This typically is the compressor (RLA), but it can also be one of the blower motors (FLA)�The data provided will cover the majority of available unit configurations. However, it should be noted that additional combinations may be available and the factory can be contacted for this data�Examples have also been provided for each configuration.

RLA = Compressor Rated Load Amps FLA = Full Load Amps (Used for Blower Motors and Electric Heaters) MCA = Minimum Circuit Ampacity (Calculated value) MOP = Maximum Fuse Size (Calculated value)

Cooling Only:

Package Unit (Can be single or dual compressor) NOTE: Largest motor amps may not always be the compressor�

MCA = (1�25 x largest motor amps) + the sum of the remaining motors MOP = (2�25 x largest motor amps) + the sum of remaining motors

Condensing Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor�

MCA = (1�25 x largest motor amps) + the sum of the remaining motors MOP = (2�25 x largest motor amps) + the sum of remaining motors

Evaporator Only Section MCA = (1�25 x Evap� Blower Motor Amps) MOP = (2�25 x Evap� Blower Motor Amps)

Condenser Only Section w/o Compressor(s) MCA = (1�25 x Cond� Blower Motor Amps) MOP = (2�25 x Cond� Blower Motor Amps)

Evaporator Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor�

MCA = (1�25 x largest motor amps) + the sum of the remaining motors MOP = (2�25 x largest motor amps) + the sum of remaining motors

Electrica Data

Page 20: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

20Subject to change without notice. 20.20-TD (0917)

Examples

Cooling Only:

Package Unit NOTE: Largest motor amps may not always be the compressor�

MCA = (1�25 x largest motor amps) + the sum of the remaining motors MOP = (2�25 x largest motor amps) + the sum of remaining motors

Single Compressor RLA = 16�7 Dual Compressors RLA = 33�3 each Evap� Blower Motor FLA = 3 Evap� Blower Motor FLA = 13�6 Cond� Blower Motor FLA = 4 Cond� Blower Motor FLA = 20�6 MCA = (1�25 x 16�7) + 3 + 4 = 27�9 MCA = (1�25 x 33�3) + 33�3 + 13�6 + 20�6 = 109�1 MOP = (2�25 x 16�7) + 3 + 4 = 44�6 MOP = (2�25 x 33�3) + 33�3 + 13�6 + 20�6 = 142�4 Rounded Down to 40 Rounded Down to 140

Condensing Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor� MCA = (1�25 x largest motor amps) + the sum of the remaining motors MOP = (2�25 x largest motor amps) + the sum of remaining motors

Single Compressor RLA = 16�7 Dual Compressors RLA = 33�3 each Cond� Blower Motor FLA = 4 Cond� Blower Motor FLA = 20�6 MCA = (1�25 x 16�7) + 4 = 24�8 MCA = (1�25 x 33�3) + 33�3 + 20�6 = 95�5 MOP = (2�25 x 16�7) + 4 = 41�6 MOP = (2�25 x 33�3) + 33�3 + 20�6 = 128�8 Rounded Down to 40 Rounded Down to 125

Evaporator Only Section MCA = (1�25 x Evap� Blower Motor Amps) MOP = (2�25 x Evap� Blower Motor Amps) Evap� Blower Motor FLA = 3 MCA = (1�25 x 3) = 3�8 MOP = (2�25 x 3) = 6�75 Rounded Down to 5

Condenser Only Section w/o Compressor(s) MCA = (1�25 x Cond� Blower Motor Amps) MOP = (2�25 x Cond� Blower Motor Amps) Cond� Blower Motor FLA = 20�6 MCA = (1�25 x 20�6) = 25�8 MOP = (2�25 x 20�6) = 46�4 Rounded Down to 45

Evaporator Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor�

MCA = (1�25 x largest motor amps) + the sum of the remaining motors MOP = (2�25 x largest motor amps) + the sum of remaining motors

Single Compressor RLA = 16�7 Dual Compressors RLA = 33�3 each Evap� Blower Motor FLA = 3 Evap� Blower Motor FLA = 13�6 MCA = (1�25 x 16�7) + 3 = 23�8 MCA = (1�25 x 33�3) + 33�3 + 13�6 = 88�5 MOP = (2�25 x 16�7) + 3 = 40 MOP = (2�25 x 33�3) + 33�3 + 13�6 = 121�8 Rounded Down to 120

Electrica Data

Page 21: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

21Subject to change without notice. 20.20-TD (0917)

Cooling with Electric Heat:

Package Unit (Can be single or dual compressor)

NOTE: Largest motor amps may not always be the compressor�

Electric Heat < 50 kW On equipment with multiple modes of operation (i�e� cooling or heating), each mode shall be evaluated and whichever load condition provides the highest value shall be used�

Use the larger of the following:

MCA = (1�25 x largest motor amps) + the sum of the remaining motors or MCA = (Heater FLA + Evap� Motor FLA) x 1�25 MOP = (2�25 x largest motor amps) + the sum of the remaining motors or MOP = (Evap� Blower Motor x 2�25) + Heater Amps

Electric Heat ≥ 50 kW

Requires Two Power Supplies

#1 Heater MCA = 1�00 x Heater FLA Heater MOP = MCA Rounded Up to Next Increment of 5 #2 Unit MCA = (1�25 x largest motor amps) + the sum of the remaining motors Unit MOP = (2�25 x largest motor amps) + the sum of the remaining motors

Evaporator Only Section Electric Heat < 50 kW

MCA = (Heater FLA + Evap� Motor FLA) x 1�25 MOP = (Evap� Blower Motor x 2�25) + Heater Amps

Electric Heat ≥ 50 kW

Requires Two Power Supplies #1 Heater MCA = 1�00 x Heater FLA Heater MOP = MCA Rounded Up to Next Increment of 5 #2 Evap� Section MCA = (1�25 x Evap� Blower Motor Amps) Evap� Section MOP = (2�25 x Evap� Blower Motor Amps)

Evaporator Section w/ Compressor(s) -- Same as Package Unit aboveCondensing Section w/ Compressor(s) or Condenser Only Section w/o Compressor(s) -- Same as Cooling Only models

Electrica Data

Page 22: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

22Subject to change without notice. 20.20-TD (0917)

Examples

Cooling with Electric Heat:

Single Package

NOTE: Largest motor amps may not always be the compressor�

Electric Heat < 50 kW

Use the larger of the following:

MCA = (1�25 x 15�6) + 3 + 5�6 = 28�1 or MCA = (26�2 + 3) x 1�25 = 36�5 Use this value MOP = (2�25 x 15�6) + 3 + 5�6 = 43�7 Use this value Rounded Down to 40 or MOP = (3 x 2�25) + 26�2 = 32�95

Electric Heat ≥ 50 kW

Requires Two Power Supplies

#1 Heater MCA = 1�00 x 157�5 = 157�5 Heater MOP = 160 #2 Unit MCA = (1�25 x 25) + 25 + 13�6 + 13�6 = 83�5 Unit MOP = (2�25 x 25) + 25 + 13�6 + 13�6 = 108�45 Rounded Down to 105

Evaporator Only Section

Electric Heat < 50 kW

MCA = (45�5 + 5�5) x 1�25 = 63�8 MOP = (5�5 x 2�25) + 45�5 = 57�9 MOP can’t be lower than MCA Rounded Up to 65

Electric Heat ≥ 50 kW

Requires Two Power Supplies

#1 Heater MCA = 1�00 x 209�9 = 209�9 Heater MOP = 210 #2 Evap� Section MCA = (1�25 x 40�5) = 50�6 Evap� Section MOP = (2�25 x 40�5) = 90

Evaporator Section w/ Compressor(s) -- Same as Single Package above

Electrica Data

Page 23: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

23Subject to change without notice. 20.20-TD (0917)

Compressor RLA Electrical Data:Tons Compressor (Qty) 208/230-1-60 208/230-3-60 460-3-60 575-3-60

3 1 16.7 10.4 5.8 3.84 1 20.5 14.6 7.1 5.15 1 26.3 15.6 7.8 5.86 2 - - - 10.4 ea. 5.8 ea. 3.8 ea.8 2 - - - 14.6 ea. 7.1 ea. 5.1 ea.10 2 - - - 15.6 ea. 7.8 ea. 5.8 ea.12 2 - - - 19.0 ea 9.7 ea. 7.4 ea.15 2 - - - 25.0 ea. 12.2 ea. 9.0 ea.20 2 - - - 33.3 ea. 17.9 ea. 12.8 ea.25 2 - - - 48.1 ea. 18.6 ea. 14.7 ea.30 2 - - - 51.3 ea. 23.1 ea. 19.9 ea.35 2 - - - 55.8 ea. 26.3 ea. 23.7 ea.

Evaporator Motor FLA:HP Used In Tons 208/230-1-60 (a) 208/230-3-60 460-3-60 575-3-60

0.33 3, 4 and 6 3 1.6 0.8 0.60.50 3, 4, 5, 6 and 8 4 2.4 1.2 0.80.75 3, 4, 5, 6 and 8 5.5 3 1.5 1.1

1 3, 4, 5, 6, 8 and 10 6.8 3.2 1.6 1.11.5 3, 4, 5, 6, 8, 10 and 12 8.2 5.6 2.4 1.62 8, 10 and 12 - - - 5.8 2.9 2.13 8, 10, 12, 15 and 20 - - - 8.4 3.9 3.15 12, 15, 20 and 25 - - - 13.6 6.4 5.2

7.5 20, 25, 30 and 35 - - - 20.6 9.9 7.110 25, 30 and 35 - - - 28.5 12.8 9.315 30 and 35 - - - 40.5 18.5 14.3

(a) Single phase motors may not be available in all tonnage sizes shown. Contact factory for specific unit capabilities.

Electrica Data

Page 24: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

24Subject to change without notice. 20.20-TD (0917)

Condenser Motor FLAHP Used In Tons 208/230-1-60 (a) 208/230-3-60 460-3-60 575-3-60

0.33 3 3 1.6 0.8 0.60.50 3 and 4 4 2.4 1.2 0.80.75 3 and 4 5.5 3 1.5 1.1

1 3, 4, 5 and 6 6.8 3.2 1.6 1.11.5 3, 4, 5, 6 and 8 8.2 5.6 2.4 1.62 4, 5, 6 and 8 - - - 5.8 2.9 2.13 5, 6, 8, 10 and 12 - - - 8.4 3.9 3.15 8, 10, 12, 15 and 20 - - - 13.6 6.4 5.2

7.5 15 and 20 - - - 20.6 9.9 7.110 25 and 30 - - - 28.5 12.8 9.315 30 and 35 - - - 40.5 18.5 14.320 35 - - - 55 25.5 18.9

Electric Heat FLA (Heaters nominally rated at 220 or 460 volts� Amps listed at 208 volts or 460 volts)

Nom. kW Used In Tons 208/230-1-60 208/230-3-60 460-3-60 575-3-605 3 22.7 13.1 6.3 5.010 3, 4, 5 and 6 45.5 26.2 12.6 10.015 4, 5, 6, 8 and 10 68.2 39.4 18.8 15.120 5, 6, 8, 10, 12 and 15 - - - 52.5 25.1 20.125 6, 8, 10, 12 and 15 - - - 65.6 31.4 25.130 8, 10,12, 15 and 20 - - - 78.7 37.7 30.135 8, 10, 12, 15, 20 and 25 - - - 91.9 43.9 35.140 10, 12, 15, 20, 25 and 30 - - - 105 50.2 40.245 10, 12, 15, 20, 25, 30 and 35 - - - 118.1 56.5 45.250 12, 15, 20, 25, 30 and 35 - - - 131.2 62.8 50.255 12, 15, 20, 25, 30 and 35 - - - 144.3 69 55.260 15, 20, 25, 30 and 35 - - - 157.5 75.3 60.280 20, 25, 30 and 35 - - - 209.9 100.4 80.3100 25, 30 and 35 - - - - - - 125.5 100.4120 30 and 35 - - - - - - 150.6 120.5140 30 and 35 - - - - - - 175.7 140.6160 35 - - - - - - 200.8 160.7

(a) Single phase motors may not be available in all tonnage sizes shown. Contact factory for specific unit capabilities.

Electrica Data

Page 25: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

25Subject to change without notice. 20.20-TD (0917)

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Air-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Condenser Motor Electrical Heat (a) (b) MCA MOP

HP FLA HP FLA KW Amps

3

208/230-1-60 16.7

0.33 3 0.33 3 - - - - - - 26.9 401 6.8 0.75 5.5 - - - - - - 33.2 45

0.33 3 0.33 3 5 22.7 32.1 401 6.8 0.75 5.5 10 45.5 65.4 70

208/230-3-60 10.4

0.33 1.6 0.33 1.6 - - - - - - 16.2 251 3.2 0.75 3 - - - - - - 19.2 25

0.33 1.6 0.33 1.6 5 13.1 18.4 251 3.2 0.75 3 10 26.2 36.8 40

460-3-60 5.8

0.33 0.8 0.33 0.8 - - - - - - 8.9 101 1.6 0.75 1.5 - - - - - - 10.4 15

0.33 0.8 0.33 0.8 5 6.3 8.9 101 1.6 0.75 1.5 10 12.6 17.8 20

575-3-60 3.8

0.33 0.6 0.33 0.6 - - - - - - 6.0 101 1.1 0.75 1.1 - - - - - - 7.0 10

0.33 0.6 0.33 0.6 5 5.0 7.0 101 1.1 0.75 1.1 10 10.0 13.9 15

4

208/230-1-60 20.5

0.33 3 0.75 5.5 - - - - - - 34.1 501.5 8.2 1.5 8.2 - - - - - - 42.0 600.33 3 0.75 5.5 10 45.5 60.6 651.5 8.2 1.5 8.2 15 68.2 95.5 100

208/230-3-60 14.6

0.33 1.6 0.75 3 - - - - - - 22.9 351.5 5.6 1.5 5.6 - - - - - - 29.5 400.33 1.6 0.75 3 10 26.2 34.8 351.5 5.6 1.5 5.6 15 39.4 56.3 60

460-3-60 7.1

0.33 0.8 0.75 1.5 - - - - - - 11.2 151.5 2.4 1.5 2.4 - - - - - - 13.7 200.33 0.8 0.75 1.5 10 12.6 16.8 201.5 2.4 1.5 2.4 15 18.8 26.5 30

575-3-60 5.1

0.33 0.6 0.75 1.1 - - - - - - 8.1 101.5 1.6 1.5 1.6 - - - - - - 9.6 100.33 0.6 0.75 1.1 10 10.0 13.3 151.5 1.6 1.5 1.6 15 15.1 20.9 25

Electrica Data

Page 26: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

26Subject to change without notice. 20.20-TD (0917)

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�(e) All unit electrical capabilities not shown. Contact factory for specific unit combinations.

Air-Cooled (c) (d) (e)

Tons Voltage CompressorRLA

Evaporator Motor Condenser Motor Electrical Heat (a) (b) MCA MOP

HP FLA HP FLA KW Amps

5

208/230-1-60 26.30.5 4 1.5 8.2 - - - - - - 45.1 700.5 4 1.5 8.2 10 45.5 61.9 70

208/230-3-60 15.6

0.5 2.4 1.5 5.6 - - - - - - 27.5 401.5 5.6 2 5.8 - - - - - - 30.9 450.5 2.4 1.5 5.6 10 26.2 35.8 401.5 5.6 2 5.8 20 52.5 72.6 75

460-3-60 7.8

0.5 1.2 1.5 2.4 - - - - - - 13.4 201.5 2.4 2 2.9 - - - - - - 15.1 200.5 1.2 1.5 2.4 10 12.6 17.3 201.5 2.4 2 2.9 20 25.1 34.4 35

575-3-60 5.8

0.5 0.8 1.5 1.6 - - - - - - 9.7 151.5 1.6 2 2.1 - - - - - - 11.0 150.5 0.8 1.5 1.6 10 10.0 13.5 151.5 1.6 2 2.1 20 20.1 27.1 30

6

208/230-3-60 10.4 ea.

0.5 2.4 1 3.2 - - - - - - 29.0 351.5 5.6 1.5 5.6 - - - - - - 34.6 450.5 2.4 1 3.2 10 26.2 35.8 401.5 5.6 1.5 5.6 25 65.6 89.0 90

460-3-60 5.8 ea.

0.5 1.2 1 1.6 - - - - - - 15.9 201.5 2.4 1.5 2.4 - - - - - - 17.9 200.5 1.2 1 1.6 10 12.6 17.3 201.5 2.4 1.5 2.4 25 31.4 42.3 45

575-3-60 3.8 ea.

0.5 0.8 1 1.1 - - - - - - 10.5 151.5 1.6 1.5 1.6 - - - - - - 11.8 150.5 0.8 1 1.1 10 10.0 13.5 151.5 1.6 1.5 1.6 25 25.1 33.4 35

Electrica Data

Page 27: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

27Subject to change without notice. 20.20-TD (0917)

Air-Cooled (c) (d) (e)

Tons Voltage CompressorRLA

Evaporator Motor Condenser Motor Electrical Heat (a) (b) MCA MOP

HP FLA HP FLA KW Amps

8

208/230-3-60 14.6 ea.

0.75 3.0 2 5.8 - - - - - - 41.7 552 5.8 3 8.4 - - - - - - 47.1 60

0.75 3.0 2 5.8 15 39.4 53.0 552 5.8 3 8.4 35 91.9 122.1 125

460-3-60 7.1 ea.

0.75 1.5 2 2.9 - - - - - - 20.4 252 2.9 3 3.9 - - - - - - 22.8 25

0.75 1.5 2 2.9 15 18.8 25.4 302 2.9 3 3.9 35 43.9 58.5 60

575-3-60 5.1 ea.

0.75 1.1 2 2.1 - - - - - - 14.8 152 2.1 3 3.1 - - - - - - 16.8 20

0.75 1.1 2 2.1 15 15.1 20.3 252 2.1 3 3.1 35 35.1 46.6 50

10

208/230-3-60 15.6 ea.

1.5 5.6 3 8.4 - - - - - - 49.1 603 8.4 5 13.6 - - - - - - 57.1 70

1.5 5.6 3 8.4 15 39.4 56.3 603 8.4 5 13.6 45 118.1 158.1 160

460-3-60 7.8 ea.

1.5 2.4 3 3.9 - - - - - - 23.9 303 3.9 5 6.4 - - - - - - 27.9 35

1.5 2.4 3 3.9 15 18.8 26.5 303 3.9 5 6.4 45 56.5 75.5 80

575-3-60 5.8 ea.

1.5 1.6 3 3.1 - - - - - - 17.8 203 3.1 5 5.2 - - - - - - 21.4 25

1.5 1.6 3 3.1 15 15.1 20.9 253 3.1 5 5.2 45 45.2 60.4 65

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�(e) All unit electrical capabilities not shown. Contact factory for specific unit combinations.

Electrica Data

Page 28: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

28Subject to change without notice. 20.20-TD (0917)

Air-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Condenser Motor Electrical Heat (a) (b) Unit Heater HP FLA HP FLA KW Amps MCA MOP MCA MOP

12

208/230-3-60 19.0 ea.

2 5.8 3 8.4 - - - - - - 57.0 75 - - - - - -5 13.6 5 13.6 - - - - - - 70.0 85 - - - - - -2 5.8 3 8.4 20 52.5 72.9 75 - - - - - -5 13.6 5 13.6 55 144.3 70.0 85 144.3 145

460-3-60 9.7 ea.

2 2.9 3 3.9 - - - - - - 28.6 35 - - - - - -5 6.4 5 6.4 - - - - - - 34.6 40 - - - - - -2 2.9 3 3.9 20 25.1 35.0 40 - - - - - -5 6.4 5 6.4 55 69.0 34.6 40 69.0 70

575-3-60 7.4 ea.

2 2.1 3 3.1 - - - - - - 21.9 25 - - - - - -5 5.2 5 5.2 - - - - - - 27.1 30 - - - - - -2 2.1 3 3.1 20 20.1 27.9 30 - - - - - -5 5.2 5 5.2 55 55.2 27.1 30 55.2 60

15

208/230-3-60 25.0 ea.

3 8.4 5 13.6 - - - - - - 78.3 100 - - - - - -5 13.6 7.5 20.6 - - - - - - 90.5 115 - - - - - -3 8.4 5 13.6 20 52.5 78.3 100 - - - - - -5 13.6 7.5 20.6 60 157.5 90.5 115 157.5 160

460-3-60 12.2 ea.

3 3.9 5 6.4 - - - - - - 37.8 45 - - - - - -5 6.4 7.5 9.9 - - - - - - 43.8 55 - - - - - -3 3.9 5 6.4 20 25.1 37.8 45 - - - - - -5 6.4 7.5 9.9 60 75.3 43.8 55 75.3 80

575-3-60 9.0 ea.

3 3.1 5 5.2 - - - - - - 28.6 35 - - - - - -5 5.2 7.5 7.1 - - - - - - 32.6 40 - - - - - -3 3.1 5 5.2 20 20.1 29.0 35 - - - - - -5 5.2 7.5 7.1 60 60.2 32.6 40 60.2 65

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Electrica Data

Page 29: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

29Subject to change without notice. 20.20-TD (0917)

Air-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Condenser Motor Electrical Heat (a) (b) Unit Heater HP FLA HP FLA KW Amps MCA MOP MCA MOP

20

208/230-3-60 33.3 ea.

3 8.4 5 13.6 - - - - - - 96.9 130 - - - - - -7.5 20.6 7.5 20.6 - - - - - - 116.1 145 - - - - - -3 8.4 5 13.6 30 78.7 108.9 130 - - - - - -

7.5 20.6 7.5 20.6 80 209.9 116.1 145 209.9 210

460-3-60 17.9 ea.

3 3.9 5 6.4 - - - - - - 50.6 65 - - - - - -7.5 9.9 7.5 9.9 - - - - - - 60.1 75 - - - - - -3 3.9 5 6.4 30 37.7 52.0 65 - - - - - -

7.5 9.9 7.5 9.9 80 100.4 60.1 75 100.4 105

575-3-60 12.8 ea.

3 3.1 5 5.2 - - - - - - 37.1 45 - - - - - -7.5 7.1 7.5 7.1 - - - - - - 43.2 55 - - - - - -3 3.1 5 5.2 30 30.1 41.5 45 - - - - - -

7.5 7.1 7.5 7.1 80 80.3 43.2 55 80.3 85

25

208/230-3-60 48.1 ea.

5 13.6 10 28.5 - - - - - - 150.3 195 - - - - - -10 28.5 15 40.5 - - - - - - 177.2 225 - - - - - -5 13.6 10 28.5 35 91.9 150.3 195 - - - - - -10 28.5 15 40.5 80 209.9 177.2 225 209.9 210

460-3-60 18.6 ea.

5 6.4 10 12.8 - - - - - - 61.1 75 - - - - - -10 12.8 15 18.5 - - - - - - 73.2 90 - - - - - -5 6.4 10 12.8 35 43.9 62.9 75 - - - - - -10 12.8 15 18.5 100 125.5 73.2 90 125.5 130

575-3-60 14.7 ea.

5 5.2 10 9.3 - - - - - - 47.7 60 - - - - - -10 9.3 15 14.3 - - - - - - 56.8 70 - - - - - -5 5.2 10 9.3 35 35.1 50.4 60 - - - - - -10 9.3 15 14.3 100 100.4 56.8 70 100.4 105

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Electrica Data

Page 30: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

30Subject to change without notice. 20.20-TD (0917)

Air-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Condenser Motor Electrical Heat (a) (b) Unit Heater HP FLA HP FLA KW Amps MCA MOP MCA MOP

30

208/230-3-60 51.3 ea.

10 28.5 10 28.5 - - - - - - 172.4 220 - - - - - -15 40.5 15 40.5 - - - - - - 196.4 245 - - - - - -10 28.5 10 28.5 40 105 172.4 220 - - - - - -15 40.5 15 40.5 80 209.9 196.4 245 209.9 210

460-3-60 23.1 ea.

10 12.8 10 12.8 - - - - - - 77.6 100 - - - - - -15 18.5 15 18.5 - - - - - - 89.0 110 - - - - - -10 12.8 10 12.8 40 50.2 78.8 100 - - - - - -15 18.5 15 18.5 140 175.7 89.0 110 175.7 180

575-3-60 19.9 ea.

10 9.3 10 9.3 - - - - - - 63.6 80 - - - - - -15 14.3 15 14.3 - - - - - - 73.4 90 - - - - - -10 9.3 10 9.3 40 40.2 63.6 80 - - - - - -15 14.3 15 14.3 140 140.6 73.4 90 140.6 145

35

208/230-3-60 55.8 ea.

7.5 20.6 15 40.5 - - - - - - 186.7 240 - - - - - -15 40.5 15 40.5 - - - - - - 206.6 260 - - - - - -7.5 20.6 15 40.5 45 118.1 186.7 240 - - - - - -15 40.5 15 40.5 80 209.9 206.6 260 209.9 210

460-3-60 26.3 ea.

7.5 9.9 15 18.5 - - - - - - 88.9 115 - - - - - -15 18.5 15 18.5 - - - - - - 97.5 120 - - - - - -7.5 9.9 15 18.5 45 56.5 88.9 115 - - - - - -15 18.5 15 18.5 160 200.8 97.5 120 200.8 205

575-3-60 23.7 ea.

7.5 7.1 15 14.3 - - - - - - 74.8 95 - - - - - -15 14.3 15 14.3 - - - - - - 81.9 105 - - - - - -7.5 7.1 15 14.3 45 45.2 74.8 95 - - - - - -15 14.3 15 14.3 160 160.7 81.9 105 160.7 165

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Electrica Data

Page 31: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

31Subject to change without notice. 20.20-TD (0917)

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Water-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Electrical Heat (a) (b) MCA MOP

HP FLA KW Amps

3

208/230-1-60 16.7

0.33 3 - - - - - - 23.9 401 6.8 - - - - - - 27.7 40

0.33 3 5 22.7 32.1 401 6.8 10 45.5 65.4 70

208/230-3-60 10.4

0.33 1.6 - - - - - - 14.6 251 3.2 - - - - - - 16.2 25

0.33 1.6 5 13.1 18.4 251 3.2 10 26.2 36.8 40

460-3-60 5.8

0.33 0.8 - - - - - - 8.1 101 1.6 - - - - - - 8.9 10

0.33 0.8 5 6.3 8.9 101 1.6 10 12.6 17.8 20

575-3-60 3.8

0.33 0.6 - - - - - - 5.4 101 1.1 - - - - - - 5.9 10

0.33 0.6 5 5.0 7.0 101 1.1 10 10.0 13.9 15

4

208/230-1-60 20.5

0.33 3 - - - - - - 28.6 451.5 8.2 - - - - - - 33.8 50

0.33 3 10 45.5 60.6 651.5 8.2 15 68.2 95.5 100

208/230-3-60 14.6

0.33 1.6 - - - - - - 19.9 301.5 5.6 - - - - - - 23.9 35

0.33 1.6 10 26.2 34.8 351.5 5.6 15 39.4 56.3 60

460-3-60 7.1

0.33 0.8 - - - - - - 9.7 151.5 2.4 - - - - - - 11.3 15

0.33 0.8 10 12.6 16.8 201.5 2.4 15 18.8 26.5 30

575-3-60 5.1

0.33 0.6 - - - - - - 7.0 101.5 1.6 - - - - - - 8.0 10

0.33 0.6 10 10.0 13.3 151.5 1.6 15 15.1 20.9 25

Electrica Data

Page 32: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

32Subject to change without notice. 20.20-TD (0917)

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�(e) All unit electrical capabilities not shown. Contact factory for specific unit combinations.

Water-Cooled (c) (d) (e)

Tons Voltage CompressorRLA

Evaporator Motor Electrical Heat (a) (b) MCA MOP

HP FLA KW Amps

5

208/230-1-60 26.30.5 4 - - - - - - 36.9 600.5 4 10 45.5 61.9 65

208/230-3-60 15.6

0.5 2.4 - - - - - - 21.9 351.5 5.6 - - - - - - 25.1 400.5 2.4 10 26.2 35.8 401.5 5.6 20 52.5 72.6 75

460-3-60 7.8

0.5 1.2 - - - - - - 11.0 151.5 2.4 - - - - - - 12.2 150.5 1.2 10 12.6 17.3 201.5 2.4 20 25.1 34.4 35

575-3-60 5.8

0.5 0.8 - - - - - - 8.1 101.5 1.6 - - - - - - 8.9 100.5 0.8 10 10.0 13.5 151.5 1.6 20 20.1 27.1 30

6

208/230-3-60 10.4 ea.

0.5 2.4 - - - - - - 25.8 351.5 5.6 - - - - - - 29.0 350.5 2.4 10 26.2 35.8 401.5 5.6 25 65.6 89.0 90

460-3-60 5.8 ea.

0.5 1.2 - - - - - - 14.3 201.5 2.4 - - - - - - 15.5 200.5 1.2 10 12.6 17.3 201.5 2.4 25 31.4 42.3 45

575-3-60 3.8 ea.

0.5 0.8 - - - - - - 9.4 101.5 1.6 - - - - - - 10.2 150.5 0.8 10 10.0 13.5 151.5 1.6 25 25.1 33.4 35

Electrica Data

Page 33: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

33Subject to change without notice. 20.20-TD (0917)

Water-Cooled (c) (d) (e)

Tons Voltage CompressorRLA

Evaporator Motor Electrical Heat (a) (b) MCA MOP

HP FLA KW Amps

8

208/230-3-60 14.6 ea.

0.75 3.0 - - - - - - 35.9 502 5.8 - - - - - - 38.7 50

0.75 3.0 15 39.4 53.0 552 5.8 35 91.9 122.1 125

460-3-60 7.1 ea.

0.75 1.5 - - - - - - 17.5 202 2.9 - - - - - - 18.9 25

0.75 1.5 15 18.8 25.4 302 2.9 35 43.9 58.5 60

575-3-60 5.1 ea.

0.75 1.1 - - - - - - 12.6 152 2.1 - - - - - - 13.7 15

0.75 1.1 15 15.1 20.3 252 2.1 35 35.1 46.6 50

10

208/230-3-60 15.6 ea.

1.5 5.6 - - - - - - 40.7 553 8.4 - - - - - - 43.5 55

1.5 5.6 15 39.4 56.3 603 8.4 45 118.1 158.1 160

460-3-60 7.8 ea.

1.5 2.4 - - - - - - 20.0 253 3.9 - - - - - - 21.5 25

1.5 2.4 15 18.8 26.5 303 3.9 45 56.5 75.5 80

575-3-60 5.8 ea.

1.5 1.6 - - - - - - 14.7 203 3.1 - - - - - - 16.2 20

1.5 1.6 15 15.1 20.9 253 3.1 45 45.2 60.4 65

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�(e) All unit electrical capabilities not shown. Contact factory for specific unit combinations.

Electrica Data

Page 34: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

34Subject to change without notice. 20.20-TD (0917)

Water-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Electrical Heat (a) (b) Unit Heater HP FLA KW Amps MCA MOP MCA MOP

12

208/230-3-60 19.0 ea.

2 5.8 - - - - - - 48.6 65 - - - - - -5 13.6 - - - - - - 56.4 75 - - - - - -2 5.8 20 52.5 72.9 75 - - - - - -5 13.6 55 144.3 56.4 75 144.3 145

460-3-60 9.7 ea.

2 2.9 - - - - - - 24.7 30 - - - - - -5 6.4 - - - - - - 28.2 35 - - - - - -2 2.9 20 25.1 35.0 40 - - - - - -5 6.4 55 69.0 28.2 35 69.0 70

575-3-60 7.4 ea.

2 2.1 - - - - - - 18.8 25 - - - - - -5 5.2 - - - - - - 21.9 25 - - - - - -2 2.1 20 20.1 27.8 30 - - - - - -5 5.2 55 55.2 21.9 25 55.2 60

15

208/230-3-60 25.0 ea.

3 8.4 - - - - - - 64.7 85 - - - - - -5 13.6 - - - - - - 69.9 90 - - - - - -3 8.4 20 52.5 76.1 85 - - - - - -5 13.6 60 157.5 69.9 90 157.5 160

460-3-60 12.2 ea.

3 3.9 - - - - - - 31.4 40 - - - - - -5 6.4 - - - - - - 33.9 45 - - - - - -3 3.9 20 25.1 36.3 40 - - - - - -5 6.4 60 75.3 33.9 45 75.3 80

575-3-60 9.0 ea.

3 3.1 - - - - - - 23.4 30 - - - - - -5 5.2 - - - - - - 25.5 30 - - - - - -3 3.1 20 20.1 29.0 30 - - - - - -5 5.2 60 60.2 25.5 30 60.2 65

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Electrica Data

Page 35: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

35Subject to change without notice. 20.20-TD (0917)

Water-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Electrical Heat (a) (b) Unit Heater HP FLA KW Amps MCA MOP MCA MOP

20

208/230-3-60 33.3 ea.

3 8.4 - - - - - - 83.3 115 - - - - - -7.5 20.6 - - - - - - 95.5 125 - - - - - -3 8.4 30 78.7 108.9 115 - - - - - -

7.5 20.6 80 209.9 95.5 125 209.9 210

460-3-60 17.9 ea.

3 3.9 - - - - - - 44.2 60 - - - - - -7.5 9.9 - - - - - - 50.2 65 - - - - - -3 3.9 30 37.7 52.0 60 - - - - - -

7.5 9.9 80 100.4 50.2 65 100.4 105

575-3-60 12.8 ea.

3 3.1 - - - - - - 31.9 40 - - - - - -7.5 7.1 - - - - - - 36.0 45 - - - - - -3 3.1 30 30.1 41.5 45 - - - - - -

7.5 7.1 80 80.3 36.0 45 80.3 85

25

208/230-3-60 48.1 ea.

5 13.6 - - - - - - 121.8 165 - - - - - -10 28.5 - - - - - - 136.7 180 - - - - - -5 13.6 35 91.9 131.9 165 - - - - - -

10 28.5 80 209.9 136.7 180 209.9 210

460-3-60 18.6 ea.

5 6.4 - - - - - - 48.3 65 - - - - - -10 12.8 - - - - - - 54.7 70 - - - - - -5 6.4 35 43.9 62.9 65 - - - - - -

10 12.8 100 125.5 54.7 70 125.5 130

575-3-60 14.7 ea.

5 5.2 - - - - - - 38.3 50 - - - - - -10 9.3 - - - - - - 42.5 55 - - - - - -5 5.2 35 35.1 50.4 55 - - - - - -

10 9.3 100 100.4 42.5 55 100.4 105

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Electrica Data

Page 36: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

36Subject to change without notice. 20.20-TD (0917)

Water-Cooled (c) (d)

Tons Voltage CompressorRLA

Evaporator Motor Electrical Heat (a) (b) Unit Heater HP FLA KW Amps MCA MOP MCA MOP

30

208/230-3-60 51.3 ea.

10 28.5 - - - - - - 143.9 195 - - - - - -15 40.5 - - - - - - 155.9 205 - - - - - -10 28.5 40 105 166.9 195 - - - - - -15 40.5 80 209.9 155.9 205 209.9 210

460-3-60 23.1 ea.

10 12.8 - - - - - - 64.8 85 - - - - - -15 18.5 - - - - - - 70.5 90 - - - - - -10 12.8 40 50.2 78.8 85 - - - - - -15 18.5 140 175.7 70.5 90 175.7 180

575-3-60 19.9 ea.

10 9.3 - - - - - - 54.2 70 - - - - - -15 14.3 - - - - - - 59.1 75 - - - - - -10 9.3 40 40.2 62.0 70 - - - - - -15 14.3 140 140.6 59.1 75 140.6 145

35

208/230-3-60 55.8 ea.

7.5 20.6 - - - - - - 146.2 200 - - - - - -15 40.5 - - - - - - 166.1 220 - - - - - -7.5 20.6 45 118.1 173.4 200 - - - - - -15 40.5 80 209.9 166.1 220 209.9 210

460-3-60 26.3 ea.

7.5 9.9 - - - - - - 70.4 95 - - - - - -15 18.5 - - - - - - 79.0 105 - - - - - -7.5 9.9 45 56.5 83.0 95 - - - - - -15 18.5 160 200.8 79.0 105 200.8 205

575-3-60 23.7 ea.

7.5 7.1 - - - - - - 60.5 80 - - - - - -15 14.3 - - - - - - 67.6 90 - - - - - -7.5 7.1 45 45.2 65.5 80 - - - - - -15 14.3 160 160.7 67.6 90 160.7 165

(a) Electric heaters nominally rated at 220, 460 or 575 volts� Amps listed at 220, 460 or 575 volts�(b) Electric heaters listed being used for heat�(c) Use Copper Conductors Only�(d) Values listed are typical and may vary dependent upon components utilized�

Electrica Data

Page 37: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

37Subject to change without notice. 20.20-TD (0917)

EVA(a) Standard refrigerant tube location is out

bottom of cabinet� Alternate tube location is outside corner post�

(b) If electrical components are added, the control box will be mounted externally�

BVA, BCVA, BVW and EVA(a) If no interconnect kit is ordered, unit will be supplied with lines capped and a holding charge only�

Basic Model Configurations

VA

EvaporatorIntake Front

EvaporatorIntake Front

EvaporatorIntake Front

EvaporatorIntake Front

CondenserBlower

CondenserBlower

CondenserBlower

Front

Front

Front

Front

Front

Front

Compressor

Compressor

Compressor

Compressor

Condenser Coil

Condenser Coil

EvaporatorDischarge Rear

EvaporatorDischarge Rear

EvaporatorDischarge Rear

EvaporatorDischarge Rear

CondenserDischarge Rear

CondenserIntake Rear

CondenserDischarge Rear

CondenserIntake Rear

Condenser Coil

CondenserDischarge Rear

CondenserIntake Rear

Condenser Coil

CondenserDischarge Rear

CondenserIntake Rear

VAR BCVA

Liquid Line

Discharge Line

VARC

Liquid Line

Suction Line

BVA

Condenser Blower

BVA

Liquid Line

Suction Line

EVA

Page 38: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

38Subject to change without notice. 20.20-TD (0917)

For specific unit dimensions, please visit our website at www.unitedcoolair.com/aurora-drawings or click here if you are viewing this document electronically�

Unit Dimensions

Page 39: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

39Subject to change without notice. 20.20-TD (0917)

Cabinet Configurations and Unit Drawings

Not to Scale

Evaporator Intake Front

Front

Front

Front

Front

Air-Cooled Air Path Configurations (2) (4)

Basic Air Path “A”Evaporator Discharge: Top

(Less the Plenum)

Basic Air Path “B”Evaporator Discharge: Top

(Less the Plenum)

Basic Air Path “C” (1)Straight Through

Evaporator Front Discharge

Basic Air Path “D” (1)Straight Through

Evaporator Rear Discharge

Optional Air Path “APT” (5) Optional Air Path “BPT” (3) (5)

OptionalAir Path“APF” (5)

OptionalAir Path“APR” (5)

OptionalAir Path“BPF” (3) (5)

OptionalAir Path“BPR” (3) (5)

EvaporatorIntake Rear

EvaporatorIntake Front

EvaporatorDischargeFront

EvaporatorDischargeRear

EvaporatorIntake Rear

CondenserDischarge Rear

CondenserIntake Rear

CondenserDischarge Rear

CondenserIntake Rear

CondenserDischarge Rear

CondenserIntake Rear

CondenserDischarge Rear

CondenserIntake Rear

Optional Plenum Optional Plenum

Reference Notes on Page 42

Page 40: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

40Subject to change without notice. 20.20-TD (0917)

Cabinet Configurations and Unit Drawings

Not to Scale

Evaporator Intake Front

Front

Front

Front

Front

Water-Cooled Air Path Configurations (2) (4)

Basic Air Path “A”Evaporator Discharge: Top

(Less the Plenum)

Basic Air Path “B”Evaporator Discharge: Top

(Less the Plenum)

Basic Air Path “C” (1)Straight Through

Evaporator Front Discharge

Basic Air Path “D” (1)Straight Through

Evaporator Rear Discharge

Optional Air Path “APT” (5) Optional Air Path “BPT” (3) (5)

OptionalAir Path“APF” (5)

OptionalAir Path“APR” (5)

OptionalAir Path“BPF” (3) (5)

OptionalAir Path“BPR” (3) (5)

EvaporatorIntake Rear

EvaporatorIntake Front

EvaporatorDischargeFront

EvaporatorDischargeRear

EvaporatorIntake Rear

Optional Plenum Optional Plenum

Reference Notes on Page 42

Page 41: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

41Subject to change without notice. 20.20-TD (0917)

Not to ScaleFor specific unit dimensions, please view them on our website at www.unitedcoolair.com/aurora-drawings or click here if you are viewing this document electronically�

Air Side Economizer (1)

Air Side Economizer (ASE) consists of dampers with operators on Return Air and Outside Air (OSA) sides, Enthalpy Sensor and Remote Mixed Air Temperature Sensor�

Notes:1� Side access required�2� Filter access available on each side of evaporator inlet�3� Side or Rear access required�4� Refer to unit drawings for specific inlet and discharge flange locations and dimensions.5� The evaporator blower motor must be upgraded when ducting out of plenum�6� Condenser filter box option includes 2”, MERV 8 Pleated Throwaway Filters.7� 3 thru 12, 20 and 25 ton units with plenums flanged for ductwork will require a motor upgrade.8� 12 thru 35 ton units, when shipped split, will have the plenum factory installed on the evaporator section,

otherwise plenum is shipped separate for field installation.

Cabinet Configurations and Unit Drawings

EvaporatorDischargeFront

Filter

Front

Right Side Rear ViewJack stands andASE field installed

Condenser Air Inlet

Condenser Air Discharge

Return Air DamperOSA Damper

Page 42: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

42Subject to change without notice. 20.20-TD (0917)

Notes:(a) If evaporator is not ducted, maintain a 24” clearance from the wall for air intake�(b) Control box location may change or it could be located externally�

Service Clearance (Plan View)

See Note (a) if evaporator intakeis not ducted

See Note (a) if evaporator intakeis not ducted

See Note (a) if evaporator intakeis not ducted

Control Box (b)

“A” Air Path “B” Air Path

“C” Air Path

Evaporator Only

“D” Air Path

30” 30” 30”

30”

30” 30”

30” 30” 30”

30” 36”

36”

36”

36”

36”

Page 43: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

43Subject to change without notice. 20.20-TD (0917)

Cooling (Air Entering Evaporator)DB (min./max.) 65 / 110WB (min./max) 57 / 72

Note: Not all combinations may be valid

Water-CooledGPM / Ton (min./max.) 2.5 / 3.5

Leaving Water Temp (min./max) 60 / 115Note: Not all combinations may be valid

Miscellaneous Technical Data

Water-Cooled UnitsFemale Pipe Threads (FPT)

Water Connection Sizes Tons Size3 - 4 3/4”5 - 8 1”

10 - 12 1-1/4”15 1-1/2”

20 - 35 2-1/2”

Voltage 208 / 230 460 575Variation 187 / 253 414 / 504 518 / 632

Condensate Drain Pipes: 1” IPS

Application Data

Page 44: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

44Subject to change without notice. 20.20-TD (0917)

Reference United CoolAir’s Louver and Ducting Guidelines TechTip for proper selection and application of wall louvers� You can view it on our website at www�unitedcoolair�com/tips or click here if you are reading this document electronically�UCA Select software is available for UCA Distributor personnel use� This software will provide unit performance data for standard applications with a Submittal Data format and unit Dimensional Drawings� Unique applications outside the norm should be communicated to the factory for confirmation of suitability for the application.

Resources

Page 45: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

Engineering Guide

VertiCool Aurora

45Subject to change without notice. 20.20-TD (0917)

Engineering Guide

VertiCool Aurora

Basic Model Designation

EXAMPLE: VA1

R2

33

G4

35

AS6

H7

A8

259

– A10

– X11

1� “VA”, “VW”, “VHW”, “E”, “B” or “BC”“VA” Air-Cooled Air Conditioner“VW” Water-Cooled Air Conditioner“VHW” Water Source Heat Pump“E” Evaporator Section only as a prefix to any of the above “BVA” Air-Cooled Condensing Section“BCVA” Air-Cooled Condenser Section“BVW” Water-Cooled Condensing Section

2� “R” or “RC” Remote Condenser or Condensing Section Being Used“R” Remote Condenser Unit being used“RC” Remote Condensing Unit being used

3� “3”, “4”, “5”, “6”, “8”, “10”, “12”, “15”, “20”, “25”, “30”, “35” Nominal Cooling Capacity in Tons

4� “G” Common to all

5� “1”, “3”, “4” or “5” Indicates Voltage“1” 208-230V, 1 PH “3” 208-230V, 3 PH“4” 460V, 3 PH“5” 575V, 3 PH

6� “AS”, “A” Quantity of Refrigerant Circuits“AS” Indicates 1 Circuit“A” Indicates 2 Circuits

7� “H” Unit Series“H” Cabinet Series

8� “A” Refrigerant Type“A” R-410A

9� “05”, “10”, “15”, “20”, “25”, “30”, “35”, “40”, “45”, “50”, “55”, “60”, “80”� “100”, “120”, “140”, “160” Indicates kW Rating for Heaters

10� “-A”, “-APF”, “-APT”, “-APR”, “-B”, “-BPF”, “-BPT”, “-BPR”, “-C”, “-D” Indicates Air Path Configuration

11� “X” Special Configuration

Not all combinations of Basic Model Designations are valid. Check with the factory for correct model identification.

Page 46: VertiCool Aurora - United CoolAir - Commercial Air ... · PDF fileEvaporator Motor FLA: ... Water-Cooled or Water Source Heat Pump Configurations • R-410A Refrigerant, ... The VertiCool

20.20-TD (0917)

Scan to learn more about all of our

products!

491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462email: [email protected] web: www.unitedcoolair.com

Copyright © by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice.

Unique Solutions for All-Indoor HVAC Projects

Authorized Distributor: LIMITED WARRANTYUnited CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty�

FACTORY TESTEDAll units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning� Industry proven components are used throughout to enhance system reliability and peace of mind�

VertiCool ClassicVertical, 3 - 30 Ton

VertiCool Aurora Vertical, 3 - 35 Tons

VariCool® VAV, 9 - 70 Tons

VariCool® EZ-FitVAV, 12 - 90 Tons

Alpha Aire100 – 500 CFM

Portable Cooling and Heating Units

3-30 Tons

C13-Series Horizontal2 - 10 Tons

C-Series Horizontal1 - 15 Tons

Special Configuration Engineered to Order

OmegaAir Horizontal and Vertical100% Outside Air 150 – 3000 CFM