Upload
henry-zevallos-tellez
View
15
Download
1
Embed Size (px)
Citation preview
Strip back approximately50mm (2 in.) of cable jacket
using Siemon AllPrep™ tool (P/N: CPT-RGTP) or equivalent.
Note: Although round cable is shown, flatcables may also be used
2
Angled MAX® 3, MAX 5e, MAX 6 & 10G™ 6 MAX Module Instructions
Pull cables through theappropriate openings in the
faceplate and mount the faceplateto the electrical box with the screwsprovided.
Note: Faceplate may be mounted before orafter cable termination.
1
View the color code label onthe module to determine
proper location of conductors basedupon preferred wiring scheme.
Note: MAX 6 shown
3a Fan out cables based ondesired wiring scheme. Cut
the rip cord or separator (if present)as close as possible to the jacket.Note: Be careful not to nick conductors.There is no need to untwist pairs,(except for bonded pairs) since the310™ block includes features to facil-itate wire lacing.
4 Insert the MAX module intothe PG-MX guard. Center
cable jacket down into 310 block (as shown above). Lace all pairs bypressing firmly into position asshown. Optionally 2-pairs can beterminated first to help secure cablebefore lacing final 2-pairs.
5a
Correct termination:Terminate using Siemon S814
termination tool or equivalent. Toolis in-line with 310 block. MAX module is contained within the PG-MX guard. PG-MX guard can beplaced on a flat surface or in aSiemon Palm Guard as shown.Note: It is recommended to use the lowimpact setting to maximize module stabilityduring termination.
6aIncorrect termination:Termination tool is not
perpendicular to the 310 block. MAXmodule is not on a stable surface orin the PG-MX guard. Cable jacket isnot within 310 termination posts.
6bFor mounting locations withlimited rear clearance, tilt
cable 90 degrees to the side asshown and lace as described in step 5a.
Note: Modules cannot be side-stacked if side entry is used.
5b Slide termination cap ontocable and snap into place prior totesting.
7
StraightEntry
SideEntry
Required Step
FOR 10G 6 MAX MODULESONLY:
Follow the color-coded label forT568A/B wiring schemes, startingwith the brown pair on the top leftIDC positions and ending with theblue pair on the bottom right positions.
3b
BROWN
BROWN
BLUE
BLUE
Rotate forward (45°) and pullstraight out.
First remove the protectivedoor before inserting into
faceplate. Align the top of the MAXmodule into the faceplate and anglethe module down until it snaps intoplace.
9 Insert the color icons by sliding them into place from
the side.To install protective rubberdoors, slide the bottom of the doorinto slot below outlet opening untilit bottoms out.
10
Insert a patch cord to preventloss of module & push down
on the icon area to defeat the toplatch.
14Press the door into the jackopening. The door will close
easily when pressed. If the door isnot aligned correctly, verify steps 12& 13 were performed correctly.
12
Rev
. B
0
8/03
100.1
2449
© 2
003
The
Siem
on C
ompa
ny
To assist safe installations, comply with the following:A. Use caution when installing or modifying telecommunications circuits.
B. Never touch uninsulated wire terminals unless the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
Remove the rubber door (if present).13
Bend door and press firmlyinto slot.
Note: Once inserted, the door hinges downward for insertion of a modular plug.Removal of the door is not required.
11Cap removal can be accomplished by prying with
a small screwdriver placed in slot asshown.
8
Angled MAX 3, MAX 5e, MAX 6 & 10G 6 MAX Module Instructions
Rotate the module (90°)backward to get the bottom
latch entirely out first. 15
Outlet Removal
16
Outlet Removal
45°
Outlet RemovalOutlet Removal
90°
www.siemon.com
Siemon — UKWoking, EnglandTel: (44) (0) 1483 480040
Siemon — USAWatertown, ConnecticutTel: (1) 866-548-5814
Siemon — Australia Sydney, AustraliaTel: (61) 2 9452 2666
Siemon — Canada Markham, OntarioTel: (1) 905 940 9223
Siemon — China Beijing, P.R. ChinaTel: (86) 10 6559 8860
Siemon — FranceParis, FranceTel: (33) 1 46 46 11 85
Siemon — Germany Frankfurt, GermanyTel: (49) (0) 69 97168 184
Siemon — ItalyMilano, ItalyTel: (39) 02 64 672 209
Siemon — Latin America Coral Gables, Florida USATel: (1) 305 446 9150
Siemon — Southeast Asia SingaporeTel: (65) 345 9119