Upload
fresz1988
View
239
Download
0
Embed Size (px)
Citation preview
8/9/2019 zenis
1/51
Zenis Software_Ver2.50Digital X-ray Total Solution
1
Zenis
Operation manual(Version 2.5)
Genoray Co., Ltd.#512 Byucksan Technopia 434-6 Sangdaewon 1-Dong
Jungwon-Gu, Seongnam-City, Gyeonggi-Do, 462-716 KOREA
Tel: +82-31-737-8020 Fax: +82-31-737-8025
www.genoray.com
http://www.genoray.com/http://www.genoray.com/http://www.genoray.com/8/9/2019 zenis
2/51
Zenis Software_Ver2.50Digital X-ray Total Solution
2
Contents
I. Introduction .............................................................................................................................................. 41.1 Introduction of Zenis Software ...................................................................................................... 4
1.2 Using Mouse ............................................................................................................................... 5
II. Window Structure .................................................................................................................................... 6
2.1 Mode Bar & Menu Bar ................................................................................................................. 7
2.2 Main Image Window .................................................................................................................. 11
2.3 Thumbnail Window .................................................................................................................... 11
III. Tool Box ............................................................................................................................................... 12
3.1 11 ........................................................................................................................................... 13
3.2 2 x 2 .......................................................................................................................................... 13
3.3 3 x 3 .......................................................................................................................................... 14
3.4 Select ........................................................................................................................................ 14
3.5 Zoom ......................................................................................................................................... 15
3.6 Pan ........................................................................................................................................... 16
3.7 Pencil ........................................................................................................................................ 17
3.8 Palette ....................................................................................................................................... 17
3.9 Magic Glass............................................................................................................................... 18
3.10 Angle ....................................................................................................................................... 19
3.11 Ellipse ...................................................................................................................................... 20
3.12 Arrow ....................................................................................................................................... 21
3.13 Polygon ................................................................................................................................... 22
3.14 Text ......................................................................................................................................... 23
3.15 Distance .................................................................................................................................. 24
3.16 Calibration ............................................................................................................................... 25
3.17 Fit ............................................................................................................................................ 26
3.18 Invert ....................................................................................................................................... 26
3.19 CW (Clockwise) ....................................................................................................................... 27
3.20 CCW (Counterclockwise) ......................................................................................................... 27
3.21 Horizontal ................................................................................................................................ 28
3.22 Vertical .................................................................................................................................... 28
3.23 L/R .......................................................................................................................................... 29
3.24 Reset ....................................................................................................................................... 29
3.25 Palette ..................................................................................................................................... 30
3.26 Filter ........................................................................................................................................ 31
8/9/2019 zenis
3/51
Zenis Software_Ver2.50Digital X-ray Total Solution
3
3.27 Play ......................................................................................................................................... 33
3.28 Window Level .......................................................................................................................... 36
IV. Exposure ............................................................................................................................................. 374.1 Registration ............................................................................................................................... 37
4.1.1 Patient Information .................................................................................................................... 38
4.2 LIH(Last Image Holder).............................................................................................................. 39
4.3 DICOM Server ........................................................................................................................... 39
4.4 Print........................................................................................................................................... 41
4.5 Modify Information ..................................................................................................................... 42
4.6 Delete Image ............................................................................................................................. 43
4.7 Close Patient ............................................................................................................................. 43
4.8 Shutdown .................................................................................................................................. 43
V. Archive.................................................................................................................................................. 44
5.1 Search ....................................................................................................................................... 44
5.2 Open Patient ............................................................................................................................. 45
5.3 Delete Patient ............................................................................................................................ 45
5.4 DICOM Server ........................................................................................................................... 46
5.5 Modify Information ..................................................................................................................... 46
5.6 Convert / Export......................................................................................................................... 46
5.7 Insert image............................................................................................................................... 48
5.8 Import patients ........................................................................................................................... 48
5.9 Shutdown .................................................................................................................................. 49
VI. Viewer ................................................................................................................................................. 49
6.1 DICOM Server ........................................................................................................................... 49
6.2 Print........................................................................................................................................... 49
6.3 Modify Information ..................................................................................................................... 49
6.4 Convert/Export........................................................................................................................... 49
6.5 Delete Image ............................................................................................................................. 50
6.6 Close Patient ............................................................................................................................. 50
6.7 Shutdown .................................................................................................................................. 50
VII. Appendix A ......................................................................................................................................... 51
8/9/2019 zenis
4/51
Zenis Software_Ver2.50Digital X-ray Total Solution
4
I. Introduction
1.1 Introduction of Zenis Software
(1) Image Analysis Software
(2) Features of Software
Field of
Application
-. To make an analysis and study of X-ray Images in an
operation room and cast room.
S/W Version ZenisSoftwareVer 2.50
Main
Function
Improvement of Image
Enlargement of Image
Length measurement of Image
Histogram of Image
Output and Storage (Database construction)
Storage of moving image
CPU Not less than IBM PC Pentium IV
OS Windows XP
8/9/2019 zenis
5/51
Zenis Software_Ver2.50Digital X-ray Total Solution
5
1.2 Using Mouse
The mouse is a manual device that moves a pointer, which is used to select objects on the screen. Themouse is a manual device that moves a pointer, which is used to select objects on the screen.
As the mouse is moved, the pointer follows in the same direction, allowing the user to navigate
through windows, menus and images. The mouse is used to perform five functions as
followings.
Left-Button Click : This is used to select menu, image and to activate function from icons.
Right-Button Click : This is used to set up basic menu of ZENIS
Double Click : This is used to change the image size.
Left-Button Drag : This is used to perform following functions;
1) To pan an image, drag the mouse up, down, left or righ.
2) To create an editable text field, click the text icon and drag the mouse the region where
you want to input text.
3) To control brightness and contrast of image, drag the mouse up, down, left or right.
Right-Button Drag : This is used to perform window level function.
Scroll : Rolling up and down the mouse wheel. Scroll is activated in main image
window and thumbnail window and used to see another images. (This is only available
when you use the wheel mouse.)
8/9/2019 zenis
6/51
Zenis Software_Ver2.50Digital X-ray Total Solution
6
II. Window Structure
Mode Bar: Mode Bar displays the name of mode.
Menu Bar : Menu Bar contains the menus used to access commands corresponding to
mode.
Tool Box : Tool Box contains the icons for the image control.
Main Image window : Main Image Window is the large area where images and/or archive
data are displayed.
Thumbnail Window: Thumbnail Window shows thumbnail(s) images of selected patient.
3
2
4
5
1
8/9/2019 zenis
7/51
Zenis Software_Ver2.50Digital X-ray Total Solution
7
2.1 Mode Bar & Menu Bar
There is 3 operation modes in Zenis.
User can change the mode by selecting a mode button, though the user does not select the
mode button, sometimes the mode changes to another mode automatically for efficiency of
work.
Each Mode has sub-menus containing all the functions and operations available in the mode
8/9/2019 zenis
8/51
Zenis Software_Ver2.50Digital X-ray Total Solution
8
(1) Exposure Mode : Exposure Mode contains Registration, LIH, DICOM Server, Print, Modify
Information, Delete Image, Close Patient, and Shutdown.
1) Registration : Enrolling patient
2) LIH (Last Image Holder) : Opening the last image hold
3) DICOM Server : Forwarding images to other PC or device.
4) Print : Printing image and patient information
5) Modify Information : Modifying patient registration information
6) Delete Image : Deleting image
7) Close Patient : Closing patient information
8) Shut down : Exit the Zenis
8/9/2019 zenis
9/51
Zenis Software_Ver2.50Digital X-ray Total Solution
9
(2) Archive Mode : Archive Mode contains Search , Open patient, Delete Patient, DICOM Server,
Modify Information, Convert/Export, Import patient, Insert images and Shutdown.
1) Search : Searching the enrolled patient information.
2) Open Patient : Opening the enrolled patient information.
3) Delete Patient : Deleting the enrolled patient information.
4) DICOM Server : Forwarding images to other PC or device.
5) Modify Information : Modifying the enrolled patient registration information
6) Convert/Export : Saving the images as the file format of BMP, JPEG,
GIF with patient information or images only.
7) Import Patients : Inputting the backed up patient registration information
or images.
8) Insert images : Saving additional image of enrolled patient.
9) Shutdown : Exit the Zenis
8/9/2019 zenis
10/51
Zenis Software_Ver2.50Digital X-ray Total Solution
10
(3) Viewer Mode : View Mode contains DICOM Server, Print, Modify Information, Convert/ Export,
Delete Image, Close patient, and Shutdown.
1) DICOM Server : Forwarding images to other PC or device.
2) Print : Printing image and patient information.
3) Modify Information : Modifying patient registration information
Convert/Export : Saving the images as the file format of BMP, JPEG, TIF
with patient information or images only.
5) Delete Image : Deleting image
6) Close Patient : Closing patient information
7) Shutdown : Exit the Zenis
8/9/2019 zenis
11/51
Zenis Software_Ver2.50Digital X-ray Total Solution
11
2.2 Main Image Window
The Main Image window shows the image and information of selected patient.
Image
Patient Information : Patients Name, ID and Date.
Window Level Status
2.3 Thumbnail Window
Thumbnail window shows the thumbnails images of a patient. Thumbnail images are shown in
screen up to maximum 7 images. If the number of images is greater than 7, the left-right arrow
button is activated and user can use it to see other images.
The image is outlined when it is selected, and the original image is presented on the main image
window.
1
2
3
1
8/9/2019 zenis
12/51
Zenis Software_Ver2.50Digital X-ray Total Solution
12
III. Tool Box
The Tool Box contains various icons for the image control and the investigation in detail.
The Tool Box for a single image is like below.
8/9/2019 zenis
13/51
Zenis Software_Ver2.50Digital X-ray Total Solution
13
3.1 11
1x 1 shows one image on the main image window in a time.
Click the 1 x 1 icon on the tool box touse.
3.2 2 x 2
2 x 2 shows four images on the main image window in a time.
Click the 2 x 2 icon on the tool box touse.
8/9/2019 zenis
14/51
Zenis Software_Ver2.50Digital X-ray Total Solution
14
3.3 3 x 3
3 x 3 shows nine images on the main image window in a time.
Click the 3 x 3 icon on the tool box touse.
3.4 Select
To select indicated text, distance or angle in image by mouse dragging
8/9/2019 zenis
15/51
Zenis Software_Ver2.50Digital X-ray Total Solution
15
3.5 Zoom
This function enables interactive zoom by mouse dragging.
To zoom an image ;
1. Select an image of a patient.
2. Click the Zoom icon on the tool box.
3. Move the mouse pointer to the main image window, the mouse pointer change its
shape like a magnifier.
4. Click left-button and drag the mouse on the image to adjust the size by Zoom function.
Zoom indrag mouse upward on the image
Zoom out - drag mouse downward on the image
< Original Image >
8/9/2019 zenis
16/51
Zenis Software_Ver2.50Digital X-ray Total Solution
16
3.6 Pan
This function is used to move the image to center a feature of interest in the main image window.
To move an image within the frame:
1. Select an image of patient to be panned.
2. Click the Pan icon on the tool box.
3. Move the mouse pointer to the main image window and the mouse pointer takes the
shape of a hand.
4. Press the left-button of a mouse at a point and drag the image to the desired position
Pan image
Pan image Pan image
Pan image
TO exit the Pan,, click another icon on the tool box.
8/9/2019 zenis
17/51
Zenis Software_Ver2.50Digital X-ray Total Solution
17
3.7 Pencil
This function is used to write or draw pictures on the image like a pencil in the main image
window.
Click Palette icon( ) to change color or thickness of lines.
Iit will be B/W line when the monitor displays only B/W.
3.8 Palette
Refer to 3.24 Palette
8/9/2019 zenis
18/51
Zenis Software_Ver2.50Digital X-ray Total Solution
18
3.9 Magic Glass
This function is used to magnify a local region of interest.
To magnify a local region of interest:
1. Select an image of a patient.
2. Click the Magic Glass icon on the tool box.
3. Move the mouse pointer to the main image window and the mouse pointer takes the
shape of a magnifying glass.
4. Click on the detail in the image that the user wants to enlarge. The image around the
mouse pointer is enlarged.
To exit the Magic Glass, click another icon on the tool panel
This function can be applied to single image only.
8/9/2019 zenis
19/51
Zenis Software_Ver2.50Digital X-ray Total Solution
19
3.10 Angle
This function is used to measure the angle among three points over an image. When the user
completes drawing an angle, the value of the angle is computed and presented automatically.
To measure an angle:
1. Select an image of patient.
2. Click the Angle icon on the tool box.
3. Move the mouse pointer to the center of angle, and click the left-button of the mouse.
4. Click the left-button of the mouse after selecting 2 different point in the image
5. The value of the angle is presented in the image automatically.
You can draw one angle only at a time. If you wish to draw another
angle, you must click the icon again.
8/9/2019 zenis
20/51
Zenis Software_Ver2.50Digital X-ray Total Solution
20
3.11 Ellipse
This function is used to draw an ellipse (including circle) over an image to indicate a region of
interest.
To draw an ellipse:
1. Select an image of patient.
2. Click the Ellipse icon on the tool box.
3. Move the mouse pointer to the main image window.
4. Click the left-button of the mouse at one of the apexes of the rectangle circumscribe
to an ellipse you want to draw. And drag the mouse in the image.
If you move the mouse pointer on the curve of an ellipse, click select button and the
mouse pointer takes the shape of 4-arrows. In this time, dragging the ellipse, you can
move the ellipse to other positions.
8/9/2019 zenis
21/51
Zenis Software_Ver2.50Digital X-ray Total Solution
21
3.12 Arrow
This function is used to draw an arrow over an image to indicate a region of interest.
To draw an arrow:
1. Select an image of patient.
2. Click the Arrow icon on the tool box.
3. Move a mouse pointer to the main image window.
4. Locate the mouse pointer on the image which is a start point and drag.
5. Stop dragging when the arrow is long enough.
8/9/2019 zenis
22/51
Zenis Software_Ver2.50Digital X-ray Total Solution
22
3.13 Polygon
This function is used to draw a polygon over an image to indicate a region of interest.
To draw a polygon:
1. Select an image of patient.
2. Click the Polygon icon on the tool box.
3. Move the mouse pointer to the main image window.
4. Locate the mouse pointer on the image which is a start point and click left-button of
mouse.
5. Draw a polygon clicking edges.
6. Click right-button of mouse to complete polygon.
8/9/2019 zenis
23/51
Zenis Software_Ver2.50Digital X-ray Total Solution
23
3.14 Text
This function is used to insert the text on an image. By using this function with line, angle and
elliptical function, you can save investigation results to database and notify it to others.
To insert a text :
1. Select an image of a patient.
2. Click the Text icon on the tool box.
3. Drag the mouse over a rectangle area where you want to insert a text.
4. Type a text in the rectangle. To end typing, Press Enter key or click the left-button of the mouse
outer region of the rectangle. Then the background changes from white color to transparent.
If you move the mouse pointer on the text area, click select button andthe mouse pointer
takes the shape of 4-arrows. In this time, dragging the text, you can move the text to another
position.
If you want to modify the text, please double click the text.
You can insert one Text only at a time. If you wish to insert more Text,
you must click the icon again.
8/9/2019 zenis
24/51
Zenis Software_Ver2.50Digital X-ray Total Solution
24
3.15 Distance
This function is used to draw a line connects between two points over an image and measure
the distance. When the drawing is completed, the distance of the line is computed and
presented automatically.
To draw a line:
1. Select an image of a patient.
2. Click the Distance icon on the tool box.
3. Move the mouse pointer to the main image window.
4. Press the left-button of the mouse at one point and drag to the other point you want to
draw a line between them.
5. The distance between two points is presented automatically.
If you move the mouse pointer on the line, the mouse pointer takes the shape of 4-arrows.
In this time, dragging the line, you can move the line to another position.
If you move the mouse pointer at the end of the line, click select button and the mouse
pointer takes the shape of cross-circle. In this time, dragging the end of the line, you can
change the direction and magnitude of the line.
There is one distance unit(mm).
The unit can be set according to pixel.
You can draw one line only at a time. If you wish to draw another line, you
must click the icon again.
8/9/2019 zenis
25/51
Zenis Software_Ver2.50Digital X-ray Total Solution
25
3.16 Calibration
This function is used to draw a line connects between two points over an image and convert
unit of measured distance from pixel to mm. When the drawing is completed, the window for
calibration of unit is presented automatically.
To calibration of unit,
1. Select an image of a patient.
2. Click the Calibration icon on the tool box.
6. Move the mouse pointer to the main image window.
7. Press the left-button of the mouse at one point and drag to the other point you want to
draw a line between them.
1. Input mm and click OK on the window for calibration of unit .
2. The value of length will be presented by mm from next time automatically.
8/9/2019 zenis
26/51
Zenis Software_Ver2.50Digital X-ray Total Solution
26
3.17 Fit
This function is used to fit an image to the window size. The original image size is fitted to the
window size.
To fit an image to the window size:
1. Select an image of a patient.
2. Click the Fit icon on the tool box.
3.18 Invert
This function is used to convert an image to the negative image.
To convert an image to the negative image:
1. Select an image of a patient.
2. Just click the Invert icon on the tool box
To convert several images to the negative images at once, after
selecting several images in the study of a patient, do the step 2.
8/9/2019 zenis
27/51
Zenis Software_Ver2.50Digital X-ray Total Solution
27
3.19 CW (Clockwise)
This function is used to rotate an image to clockwise by 90.
To rotate an image to clockwise:
1. Select an image of a patient.
2. Click the CW icon on the tool box.
It is only possible to rotate an image by 90 at one time.
To rotate several images at once, after selecting several images in the study of a patient, do the step 2.
3.20 CCW (Counterclockwise)
This function is used to rotate an image to counterclockwise by 90.
To rotate an image to counterclockwise:
1. Select an image of a patient.
2. Click the CCW icon on the tool box.
It is only possible to rotate an image by 90 at one time.
To rotate several images at once, after selecting several images in the study of a patient, do the step 2
8/9/2019 zenis
28/51
8/9/2019 zenis
29/51
Zenis Software_Ver2.50Digital X-ray Total Solution
29
3.23 L/R
This function is used to indicate Left, Right on left side of an image to the vertical mirror image.
To indicate Left, Right,
1. Select the image of a patient.
2. Click the L/R icon on the tool box.
3.24 Reset
This function is used to reset adjusted brightness and contrast of image.
To reset,
1. Select adjusted image.
2. Click the Reset icon on the tool box.
8/9/2019 zenis
30/51
Zenis Software_Ver2.50Digital X-ray Total Solution
30
3.25 Palette
This function is used to change color of line and text for Distance, Ellipse, Text, Angle, Arrow
and Pencil and set Pencil thickness, Text Size for writing test and Text size for indicating
information.
To use Palette
1. Click Palette icon.
2. Change the color and/or value.
3. Click Applybutton
8/9/2019 zenis
31/51
Zenis Software_Ver2.50Digital X-ray Total Solution
31
3.26 Filter
This function is used tofiltrate the image with basic filter function..
To use Filter function,
1. Click Filter icon.
2. Select filter type and adjust filter strength.
3. Click Applybutton.
8/9/2019 zenis
32/51
Zenis Software_Ver2.50Digital X-ray Total Solution
32
8/9/2019 zenis
33/51
Zenis Software_Ver2.50Digital X-ray Total Solution
33
3.27 Play
This function is used to save image as moving image format (AVI).
3.27.1 Play Menu
Play moving image.
Stop the moving image in play.
Record moving image. (At Play mode, it is not revitalized.)
Pause moving image in play.
Backward moving image in play.
Forward moving image in play.
Backward moving image in Play more than Bwd icon at one click.
Forward moving image in Play more than Fwd icon at one cl ick.
Set moving image
Close Ply mode of moving image.
3.27.2 Save moving image
1. Click Play icon.
2. Click Settingicon.
3. Set Frame rete.
8/9/2019 zenis
34/51
Zenis Software_Ver2.50Digital X-ray Total Solution
34
No. Frame/secMax. recording
time1 30 172 15 35
3 7.5 714 3.75 1425 1 534
4. Check With sound if you want to record sound with micro phone which is installed in PC.
5. Click Apply when setting is completed.
6. Click Recordicon.
7. Click Start to record button.
8. Click Stop to record to stop recording.
When max. recording time is exceeded, take frames from the first.
9. Save moving image taken to PC.
8/9/2019 zenis
35/51
Zenis Software_Ver2.50Digital X-ray Total Solution
35
3.27.3 PLAY
1. Select moving image indicated Live at the right bottom of image.
2. Click Play icon.3. Selected moving image is played automatically.
8/9/2019 zenis
36/51
Zenis Software_Ver2.50Digital X-ray Total Solution
36
3.28 Window Level
(Non icon image)
This function is used to adjust the window level(brightness and contrast) of an image.
The current window level values are shown in the bottom left-hand corner of the image. The
adjusting method is same with default function. But you can use right-button dragging.
To adjust the window level of an image:
1. Select an image of a patient.
2. Click the right-button of mouse on the image.
3. Mouse pointer takes the shape of a shining sun and half dark-bright circle.
4. Click and drag within the image. The image values are altered simultaneously.
To adjust window level of several images at once, After you want
to select an image, hold on pressing [Ctrl] key while you are
doing the step 1~4.
Brightness +
Brightness -
Contrast - Contrast +
8/9/2019 zenis
37/51
Zenis Software_Ver2.50Digital X-ray Total Solution
37
IV. Exposure
The Exposure mode is consisted of 8 menus. This mode is used to take an X-ray image of apatient.
4.1 Registration
The Patient Registration is used to:
1. Register the current patient.
2. Manage reserved information of patients from the worklist server.
3. Register an emergency patient.
To run the Patient Registration, click the Registration menu. Then the window in next page will
appear. There are two tabs, Patient Register Information and Worklist. Each has a function as
following:
1. Patient Register Information is used to register a new patient.
2. Worklist is used to manage reserved information of patients from the worklist server.
8/9/2019 zenis
38/51
8/9/2019 zenis
39/51
Zenis Software_Ver2.50Digital X-ray Total Solution
39
4.2 LIH(Last Image Holder)
Saving the last image hold.
4.3 DICOM Server
Forwarding images to other PC or Main Server.
To run the DICOM Server, click the DICOM Server menu. Then the window in next page will
appear. There are two tabs, the image storage items and Status log. Each has a function as
following:
1. The image storage items is used to appear selected image of patient for DICOM translation.
2. Status log is used to appear DICOM translation status.
8/9/2019 zenis
40/51
Zenis Software_Ver2.50Digital X-ray Total Solution
40
4.3.1 Selecting Option
If you click the DICOM Server button, the dialog box as following will pop up.
You can select whether to transfer the all images or the selected images.
-Cancel: Abort the transformation
-OK: Proceed the transformation
4.3.2 Configure Storage Server and Worklist Server
1. Click the Configure button and the following dialog box will pop up.
2. Input the information of item and click the OK button.
You cantapply the configuration while the DICOM transformation is running.
8/9/2019 zenis
41/51
Zenis Software_Ver2.50Digital X-ray Total Solution
41
4.4 Print
This menu is used to print current image of patient.
To print, click Print icon and then new window will be opened.
There are 2 partsPrinter and Printer Images in the new window. The functions of each are;
1. Select printer at Printer part.
2. Select images which will be printed.
3. Set the information which display on printed image.
8/9/2019 zenis
42/51
Zenis Software_Ver2.50Digital X-ray Total Solution
42
4.5 Modify Information
Modify information is used to modify the information of a patient.
The method of modifying the item is all the same with Patient Registration menu.
See 4.1 Registration
8/9/2019 zenis
43/51
Zenis Software_Ver2.50Digital X-ray Total Solution
43
4.6 Delete Image
This menu is used to delete the selected image of patient.
To delete several images at once, After hold on pressing [Ctrl] key,
you select the image.
4.7 Close Patient
The Close Patient menu is used to close all the information and images of a selected patient
4.8 Shutdown
The Shutdown menu is used to exit the Zenis Software.
If you click O.K button, Zenisis off.
8/9/2019 zenis
44/51
Zenis Software_Ver2.50Digital X-ray Total Solution
44
V. Archive
The Archive mode is consisted of 8 menus. This mode is used to search and deleteinformation of all the enrolled patients and etc..
5.1 Search
This menu is used to search the information of all the enrolled patients.
To search the information of patient:
1. Click the Search menu.
2. Then the below dialog box will appear.
3. Search Range: You can select any condition in the dialog box as following:
8/9/2019 zenis
45/51
Zenis Software_Ver2.50Digital X-ray Total Solution
45
5.2 Open Patient
The Open Patient menu is used to open the data of selected patient.
To open the data of a patient:
1. Select a patient in the list.
2. Click the Open Patient menu, the Archive mode changes to the Viewer mode
automatically.
3. The Archive mode changes to the Viewer mode automatically.
You cant open several data of patients at once.
5.3 Delete Patient
The DeletePatient menu is used to delete all the data of a selected patient.
To delete the data of a patient:
1. Select a patient in the list.
2. Click the Delete Patient menu and the data of the patient is deleted from the local
database.
If you want to delete several patients at once, hold on pressing
[Ctrl] key while you are selecting patients in the list.
8/9/2019 zenis
46/51
Zenis Software_Ver2.50Digital X-ray Total Solution
46
5.4 DICOM Server
This is all the same with the DICOM Server in the Exposure mode.
See 4.3 DICOM Server.
5.5 Modify Information
This is all the same with the Modify Information in the Exposure mode.
See 4.5 Modify Information.
5.6 Convert / Export
The Convert / Export Images is used to save the image with information of patient or only
Image of patient at users local HDD.
Function of this menu is as below.
5.6.1 File Type: You can select an image format in BMP, JPEG , TIF, PNG and GIF.
5.6.2 Destination Directory : You can restore the images in the arbitrary directory in the local
HDD.
8/9/2019 zenis
47/51
8/9/2019 zenis
48/51
Zenis Software_Ver2.50Digital X-ray Total Solution
48
5.7 Insert image
The insert images menu is usedto insert images to enrolled patient.
1. Select a patient on the list and click Insert images icon.
2. The window moves to Exposure mode automatically and you can insert images.
5.8 Import patients
The Import patient menu is used to input existing back-up file.
To input back-up file,
1. Click Import patients on the list.
2. Set the folder which back-up file in.
3. Click Import patientbutton, back-up file will be input on the list.
8/9/2019 zenis
49/51
Zenis Software_Ver2.50Digital X-ray Total Solution
49
5.9 Shutdown
This is all the same with the Shutdown in the Exposure mode.
See 4.8 Shutdown.
VI. Viewer
In the Viewer mode, you can apply various image processes to a correction needed image and
investigate the image in detail with various tools.
6.1 DICOM Server
This is all the same with the DICOM Server in the Exposure mode.
See 4.3 DICOM Server.
6.2 Print
This is all the same with the Print in the Exposure mode.
See 4.4 Print.
6.3 Modify Information
This is all the same with the Modify Information in the Exposure mode.
See 4.5 Modify Information.
6.4 Convert/Export
This is all the same with the Convert/Export in the Archive mode.
See 5.6 Convert/Export
8/9/2019 zenis
50/51
Zenis Software_Ver2.50Digital X-ray Total Solution
50
6.5 Delete Image
This is all the same with the Delete Image in the Exposure mode.
See 4.6 Delete Image.
6.6 Close Patient
This is all the same with the Delete Patient in the Exposure mode.
See 4.7 Delete Patient.
6.7 Shutdown
This is all the same with the Shutdown in the Exposure mode.
See 4.8 Shutdown .
8/9/2019 zenis
51/51