    DOMEKT

    Domekt R 250 F (DomektREGO250P)

    B

    D

    A

    C

    B

    D

    A

    C

    E

    D

    A

    C

    B

    DC

    AB

    61

    68

    61

    68

    42

    31

    250

    25

    41

    1~ 230

    HE 6,3 / HW 2,3

    82

    0,05

    50

    0,48

    278×258×46-M5

    36

    96

    1,0 / 16,5

    KOMFOVENT C4 / C4.1

    0,8 0,8 0,8 0,8

    36 36 36 36

    1 1 1 1

    12/22

    2,2 1,8 1,3 0,9

    ½

    315x315x220

    DH-160

    C4

    C4.1

    B

    250 m³/h42

    0 0,02 0,04 0,06 0,08

    0 50 100 150 200 250 300

    250

    200

    150

    100

    50

    0

    SFP 0,75

    SFP 0,5

    SFP 1

    SFP 1,25

    50 100 150 200 250 300

    92

    88

    84

    80

    76

    72

    12 13,8 14,9 16 17,1 23,820 205125

    280

    20

    155 155790

    310 310830

    125

    175

    125

    175

    550

    160 (4×)

    KK2-16-03UAB AMALVA reserves the right to introduce the changes of parameters and sizes in the process of improvement of the air handling units.All data can be calculated in DOMEKT selection software. If data of performance do not correspond to data in the selection software, please refer to data shown in software.

    The

    phot

    o is

    inte

    nded

    for i

    nfor

    mat

    iona

    l pur

    pose

    s on

    ly, e

    xact

    det

    ails

    may

    var

    y.

    Stat

    ic p

    ress

    ure

    (Pa)

    Performance Air flow rate (m3/s)

    Air flow rate (m3/h)

    Air flow rate (m3/h)

    Tem

    p. e

    ffici

    ency

    (%)

    Temperature efficiency

    Indoor and outdoor ∆T=13°C re: Ecodesign 1254/2014.

    Acoustic DataA-weighted sound power level LwA, dB(A)at reference flow rate

    Supply Inlet

    Supply Outlet

    Exhaust Inlet

    Exhaust Outlet

    Casing

    A-weighted sound pressure level LPA, dB(A) 10 m² normally isolated room, distance from casing – 3 m.

    Surroundings

    Nominal air flow, m³/h

    Panel thickness, mm

    Unit weight, kg

    Supply voltage, V

    Maximal operating current, A

    Thermal efficiency of heat recovery, %

    Reference flow rate, m³/s

    Reference pressure difference, Pa

    SPI, W/(m³/h)

    Filters dimensions B×H×L, mm

    Electric power input of the fan drive at reference flow rate, W

    Electric power input of the fan drive at maximum flow rate, W

    Electric air heater capacity, kW / ∆t, °C

    Control panel

    Hot water duct air heater (DH)**winter

    Water temperature in/out, °C 90/70 80/60 70/50 60/40

    Capacity, kW

    Flow rate, dm³/h

    Pressure drop, kPa

    Temperature in/out, °C

    Maximal capacity, kW

    Connection, ”

    Dimensions, mm

    Hot water duct heater type

    ** option

    Temperature efficiencywinter Summer

    Outside temperature, °C -23 -15 -10 -5 0 30

    After heat exchanger*, °C

    * indoor +22°C, 20 % RH

    A outdoor intakeB supply airC extract indoorD exhaust airE additional extraction connection (by-pass –

    extraction without heat recovery)

    Shown as right (R2)

    Shown as left (L2)


Recommended