AC axial fan - HyBlade®
sickled blades (S series)with guard grille for short nozzle
S4E500-AM03-01
ebm-papst Mulfingen GmbH & Co. KGBachmühle 2 · D-74673 MulfingenPhone +49 7938 81-0Fax +49 7938 [email protected] partnership · Headquarters MulfingenCounty court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters MulfingenCounty court Stuttgart · HRB 590142
Nominal data
Type S4E500-AM03-01Motor M4E110-GF
Phase 1~ 1~Nominal voltage VAC 230 230Frequency Hz 50 60
Type of data definition ml mlValid for approval / standard CE CESpeed min-1 1300 1400Power input W 680 880Current draw A 3.0 3.88Motor capacitor µF 12 12Capacitor voltage VDB 450 450Max. back pressure Pa 150 100Min. ambient temperature °C -40 -40Max. ambient temperature °C 65 40ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unitSubject to alterations
Data according to ErP directive
Installation category AEfficiency category StaticVariable speed drive NoSpecific ratio* 1.00* Specific ratio = 1 + pfs / 100 000 Pa
Actual Request 2013 Request 2015
Overall efficiency ηes 32.5 28.5 32.5Efficiency grade N 40 36 40Power input Pe kW 0.65Air flow qv m³/h 5765Pressure increase pfs Pa 129Speed n min-1 1315Data established at point of optimum efficiency
Item no. 10081-5-9980 · Revision 74126 · Release 2011-09-26 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)with guard grille for short nozzle
S4E500-AM03-01
Technical features
Size 500 mmSurface of rotor Coated in blackMaterial of terminal box PC/ABS plastic, blackMaterial of blades Press-fitted sheet steel blank, sprayed with PP plasticMaterial of guard grille Steel, phosphated and coated in black plasticNumber of blades 5Direction of air flow "V"Direction of rotation Counter-clockwise, seen on rotorType of protection IP 54Insulation class "F"Humidity class F4-1Max. permissible ambient motortemp. (transp./ storage)
+ 80 °C
Min. permissible ambient motortemp. (transp./storage)
- 40 °C
Mounting position Shaft horizontal or rotor on bottom; rotor on top on requestCondensate discharge holes Rotor-sideOperation mode S1Motor bearing Ball bearingTouch current acc. IEC 60990(measuring network Fig. 4, TNsystem)
<= 3.5 mA
Electrical leads Via terminal box, integrated capacitor connected via terminal boxMotor protection Thermal overload protector (TOP) brought outCable exit AxialProtection class I (if protective earth is connected by customer)Product conforming to standard EN 61800-5-1; CEApproval GOST; VDE; UL 1004-1; CSA C22.2 Nr.100
Item no. 10081-5-9980 · Revision 74126 · Release 2011-09-26 · Page 2 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)with guard grille for short nozzle
S4E500-AM03-01
Product drawing
1 Direction of air flow "V"2 Tightening torque 0.8±0.15 Nm3 Cable diameter: min. 6 mm, max. 12 mm, tightening torque: 2.0±0.3 Nm
Item no. 10081-5-9980 · Revision 74126 · Release 2011-09-26 · Page 3 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)with guard grille for short nozzle
S4E500-AM03-01
Connection screen
L = U1 = blue Z brown N = U2 = blackPE green / yellow TOP grey
Item no. 10081-5-9980 · Revision 74126 · Release 2011-09-26 · Page 4 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)with guard grille for short nozzle
S4E500-AM03-01
Charts: Air flow 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]9.0008.0007.0006.0005.0004.0003.0002.0001.0000
qv[cfm]5.0004.0003.0002.0001.0000
]aP[sf p
190185180175170165160155150145140135130125120115110105100
959085807570656055504540353025201510
50
pfs
_E[IN
H2O
]
0,760,740,720,70,680,660,640,620,60,580,560,540,520,50,480,460,440,420,40,380,360,340,320,30,280,260,240,220,20,180,160,140,120,10,080,060,040,020
]aP[s
f p
1
2
3
4
Measurement: LU-107128
Air performance measured as per ISO 5801Installation category A. For detailedinformation on the measuring set-up, pleasecontact ebm-papst. Suction-side noiselevels: LwA measured as per ISO 13347 /LpA measured with 1m distance to fan axis.The values given are valid under themeasuring conditions mentioned above andmay vary according to the actual installationsituation. With any deviation from thestandard set-up, the specific values have tobe checked and reviewed with the unitinstalled.
Measured values
1234
UV230230230230
fHz50505050
nmin-1
1380135513301300
Pe
W513571623680
IA2.252.502.733.00
LpAin
dB(A)68656365
LwAin
dB(A)75727072
LwAout
dB(A)75727071
qvm3/h8905793067055140
pfs
Pa050100150
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side · LwAout = Sound power level outlet sideqv = Air flow · pfs = Pressure increase
Item no. 10081-5-9980 · Revision 74126 · Release 2011-09-26 · Page 5 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)with guard grille for short nozzle
S4E500-AM03-01
Charts: Air flow 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]13.00012.00011.00010.0009.0008.0007.0006.0005.0004.0003.0002.0001.0000
qv[cfm]7.0006.0005.0004.0003.0002.0001.0000
]aP[sf p
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
pfs
_E[IN
H2O
]
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
]aP[s
f p
1
2
3
4
Measurement: LU-107130
Air performance measured as per ISO 5801Installation category A. For detailedinformation on the measuring set-up, pleasecontact ebm-papst. Suction-side noiselevels: LwA measured as per ISO 13347 /LpA measured with 1m distance to fan axis.The values given are valid under themeasuring conditions mentioned above andmay vary according to the actual installationsituation. With any deviation from thestandard set-up, the specific values have tobe checked and reviewed with the unitinstalled.
Measured values
1234
UV230230230230
fHz60606060
nmin-1
1530148514501400
Pe
W793828853880
IA3.453.613.733.88
LpAin
dB(A)70686665
LwAin
dB(A)77757372
LwAout
dB(A)78757372
qvm3/h9850899082207300
pfs
Pa04070100
U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side · LwAout = Sound power level outlet sideqv = Air flow · pfs = Pressure increase
Item no. 10081-5-9980 · Revision 74126 · Release 2011-09-26 · Page 6 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com