16
fagerhult e-sense Added intelligence

FAGERHULT | e-sense

Embed Size (px)

Citation preview

Page 1: FAGERHULT | e-sense

fagerhult e-sense

Added intelligence

Page 2: FAGERHULT | e-sense

Some forms of technology have been steeped in

mystery to the extent that they negate the purpose

for which they were designed.

Light control is such an example. A technology

that was born from our need of ergonomic and

energy-saving lighting. Obvious, yet too diffi cult

to understand. Both to those planning, the person

installing, and to the person who has to use it.

At last the technology has fi nally matured and Fa-

gerhult can now introduce a unique concept. e-Sense

– added intelligence. All you need to do is to connect

the luminaire and press a button.

Our aim has been to eliminate all the hidden costs

of installation, operation and maintenance. To avoid

switches and complicated settings. You install a nor-

mal luminaire, but get a complete control system.

With e-Sense each luminaire in the room can

think for itself, or as one system. The luminaires

have a newly developed multisensor that detects

movement in the room, measures the daylight and

and adapts the output accordingly. You determine

its level of intelligence by selecting from two system

models, the fully featured e-Sense ActiLume or the

basic model e-Sense SmartSwitch. No matter what

you choose the luminaire takes care of itself.

On the other hand, there is nothing more frustra-

ting than infl exible technology. If you want to you

can control the light yourself, with the help of a pull

switch. And if you want to refurnish your offi ce, it's

not a problem as the luminaire is an independent

working unit. Time consuming and costly repro-

gramming is no longer needed.

e-Sense represents ease of use, effi ciency, energy

and economy. Easy to install and use. Effective with

regard to light treatment and energy consumption

– you save up to 75 per cent. Ergonomic as you look

after visual and psychological needs. Economy is the

sum of all parts. We have integrated light control

into the system, so you can divert your energies

elsewhere. A smart move we think.

Fagerhult e-Sense – lighting control made simple

Page 3: FAGERHULT | e-sense

Fagerhult e-Sense – you control the design

Fagerhult e-Sense is the smart way to save energy.

One of the most diffi cult choices you have to make is between form

and function. This has been the case for a long time within light control.

Choosing a light control function limited the number of luminaire models

available, while those who gave priority to design had to cope with com-

plicated control systems – or no control at all. This was an insult to all the

architects, light planners and interior designers that applied a holistic ap-

proach to their work. Consequently, we now offer e-Sense on virtually all

luminaires in our product range. Which refl ects the growing importance

we attach to integrated lighting control.

Initially we will offer various leading products in an e-Sense design with

ready-to-install order numbers. Install, connect and start experiencing the

benefi ts of control.

We also offer e-Sense MLS, with a range of existing luminaires incorpo-

rating the new miniaturized sensor from Ex-Or, the DH sensor.

Further details available on request.

Fagerhult e-sense is the easiest, quickest way to install light control. All you have to do is to connect it. And the system is up and running. If you want to make personal set-tings, you can do this by pressing the service button and selecting between the two most common operating functions. It couldn’t be easier.

Page 4: FAGERHULT | e-sense

BA

Fagerhult e-Sense luminaires are equipped with integrated light control. An attractive, easy installation without the need of add-on or external sensors. No connections – no problems.

e-Sense ActiLume

ActiLume is a control system based on

the DALI protocol. The system consists of

a detector and a controller. The sensor

has three different parts: a detector for

presence, a sensor for daylight control and

an IR receiver should you want to use a

remote control.

e-Sense ActiLume offers maximum

comfort and energy savings up to 75 %.

The immense energy saving potential gives

the possibility of repaying the investment

quickly.

The system also offers the user the

chance to adjust the lighting to his/her

personal level with the help of a retractable

switch, pull cord or a remote control.

The master luminaire can control ten

others (11 HF-ballasts). The system has two

channels, A and B. Channel B has a 30 %

offset, which means that Channel B starts

to be regulated when channel A drops to

70 %. When channel A is regulated to 10 %,

channel B is then set to 40 %.

In recessed installations channel A can

control the luminaires close to the window

where there is more incoming daylight, and

channel B control luminaires away from

the windows.

In pendant three lamp luminaires (with

two ballasts) we use the system to control

the direct and indirect light separately with

channel B controlling the indirect light.

Fagerhult e-Sense – two systems, same simplicity

Page 5: FAGERHULT | e-sense

e-Sense SmartSwitch

SmartSwitch is an on/off-sensor that con-

trols the connected luminaire via the mains

voltage. There is also a model with pull dim

for individual setting of the lighting level

available. SmartSwitch gives automatic ig-

nition/extinguishing controlled by presence

and the ambient light. The presence detec-

tion can be set with a delay of between 1

to 30 minutes.

When the amount of ambient light

(daylight) is suffi cient the lighting is swit-

ched off, the lighting level that activates

switching off can be set between 50–2000

lux. This function can be omitted.

e-Sense SmartSwitch absence dimming

A control function adapted to a room in an

offi ce which is used sparingly, for example,

a copying room, stockroom, corridors or

a cloakroom. The lighting level is set at a

constant low level to counteract the im-

pression of a darkened room. Any presence

is detected and the lighting is adjusted to

100 %. The time delay to return to the low

level (10 %) can be short unlike control with

a switch off function where you need to av-

oid unnecessary starting of the fl uorescent

lamp. If you wish to switch off the lumin-

aire completely, this can be done centrally

once working hours are over.

In addition, with the setting for lux

on/off you can prevent control if there is

already suffi cient light in the room. Adjust-

ment of the time and lux level are made on

the rear of the sensor.

Fagerhult e-Sense – two systems, same simplicity

Page 6: FAGERHULT | e-sense

BA

e-Sense ActiLumeFunctions offered by e-Sense luminaires equipped with ActiLume

Presence detection

Presence control switches the lighting on and off auto-

matically. After the last presence detection the lighting

is switched off with a 15 minutes delay.

Daylight control

A sensor adapts the lighting output to the amount of

incidental light (natural light). If there is no daylight,

this function regulates the light output to maintain

the required illumination level.

IR-receiver

To control and programme using the remote control if

required. The remote control is an accessory.

Manual control (touch)

Full manual control via pull dim in the luminaire or

retractive switch on the wall.

Channel B 30 % offset

Channel B has a 30 % offset, which means that channel

B starts to be regulated when channel A drops to 70 %.

When channel A is regulated to 10 %, channel B is then

set to 40 %.

ActiLume offers maximum comfort and au-

tomatic energy saving. ActiLume adapts the

level of light to the surrounding environ-

ment and when the room is not in use the

light is switched off.

When the sensor detects presence, the

system automatically switches the light

on. If there is suffi cient daylight in a room

the level is automatically dampened. The

light is switched off when the room has

been empty for some time. As light is only

on when needed, the system can give the

energy savings up to 75 %.

Night: The offi ce is in darkness. 07:56 The luminaire is switched on with presence as the daylight does not satisfy the lighting need.

Daylight reduces the luminaire light accordingly, also known as daylight control.

Adjustment is performed slowly and constantly according to a set value. When dimmed, the uplight is 30% higher than the downlight.

The series of pictures shows what happens in the room. The curve shows how the luminaire's energy use varies throughout the day.

Page 7: FAGERHULT | e-sense

e-Sense ActiLume – pendant 2-lamp luminaires

Choices for presence detection: Automatic ON Automatic OFF (delay 15 minutes)

Manual ON (with a light level over 600 lux) Automatic OFF (delay 15 minutes)(Always adjustment to low level before OFF).

Choices for daylight sensor: Automatic setting to 600 lux.Manual setting adjustment.

Choices for manual control: Pull dim (only pendant luminaires) or retractive switch on/off and control.

IR-transmitter on/off and control (accessory).

e-Sense ActiLumeFunctions offered by e-Sense luminaires equipped with ActiLume

e-Sense ActiLume – pendant 3-lamp luminaires

Choices for presence detection: Automatic ON Automatic OFF (delay 15 minutes).

Manual ON (with a light level over 600 lux) Automatic OFF (delay 15 minutes).

(Always adjustment to low level before OFF).

Choices for daylight sensor: Automatic setting to 600 lux.Manual setting adjustment.

Choices for manual control: Pull dim (only pendant luminaires) or retractive switch on/off and common control of downlight/uplight.IR-transmitter on/off and control (accessory).

Special functions, pendant or recessed installations: 30 % offset, uplight adjusted to 30 % above the downlight with dimming.

In recessed installations channel A can control the luminaires close to the win-dow where there is more incoming daylight, and channel B controls luminaires away from the windows.

Lunch: After the last presence, the light is softened and switched off after 15 minutes.

The luminaire is not switched by presence as the light requirement is provided by incidental daylight.

Manual or automatic control to satisfy the lighting requirement.

After the last presence, the light is dimmed and switched off after 15 minutes.

Page 8: FAGERHULT | e-sense

e-Sense SmartSwitchFunctions offered by e-Sense luminaires equipped with SmartSwitch

Presence detection Presence control switches the lighting on and off. After

the last presence detection the light is automatically

switched off. The time between detection and swit-

ching off is adjustable, 1–30 minutes.

Lux level setting

Setting the threshold value prevents the presence de-

tector reacting when daylight is suffi cient.

Manual control

Icons suggest that retractable switch operation

is also possible.

Absence dimming

The presence detector adjusts to a high light level on

detection and returns to a low level after a short period

of time. No switch off function.

Night: The offi ce is in darkness 07:56 Automatic ignition. Manual control of uplights and downlights.

The light is switched off according to the time set on the sensor, approximately 15 minutes.

Night: The light is set to a low basic level.

The light switches to a higher level when presence is detected.

The delay after the last presence is short, approx. 5 minutes.

After 5 minutes the light is adjusted down to the basic level.

The series of pictures show two SmartSwitch models. The upper series of pictures shows a combination with manual control, e-Sense

Smart Switch ensures that the light in the room is switched off when not in use. The lower series of pictures shows how energy usage

reduces considerably with the use of absence dimming.

Page 9: FAGERHULT | e-sense

e-Sense SmartSwitch On/Off – luminaires without dim-mable HF ballasts

Choices for presence detection: Automatic ON/OFF (set time 1–30 minutes).Not ON (when the lux level is above the set value) Automatic OFF.

Choices for the Lux sensor: Not ON with high lux level.Manual modifi cation of the setting for the lux level (50–2000 lux).

Note: The luminaire does not have a dimmable HF-ballast, the function is only ON/OFF.

e-Sense SmartSwitch – pendant luminaire with dimma-ble HF-ballast

Choices for presence detection: Automatic ON/OFF (set time 1–30 minutes).

Choices for manual control: Pull dim ON/OFF and dimming.

Special functions: The luminaire is equipped with an ECO-lp HF-ballast with memory function when switched off.

Note: Do not use a lux level setting. If the room is bright and the sensor does not ignite, the cord will not work.

e-Sense SmartSwitchFunctions offered by e-Sense luminaires equipped with a Tridonic SmartSwitch

e-Sense SmartSwitch with absence dimming – with dimmable HF-ballast

Choices for presence detection: Automatic HIGH/LOW (set time 1–30 minutes).If the lux level is above the set value light remains on low level.

Choices for manual control: None.

Special functions: The luminaire is equipped with an ECO-lp HF-ballast that automatically repli-cates the Absence dimming function after fi ve minutes.

Note: No OFF function, the level is permanently set to 10 % value if no presence is detected.

Page 10: FAGERHULT | e-sense

Loop Light is a well-designed

classic from Fagerhult. The lu-

minaire has white or alu-grey

body of extruded aluminium

and ends of cast metal.

The sensor unit is located in

the luminaire's end cap.

Loop Light Beta ActiLume SmartSwitch SmartSwitch SmartSwitch

Pull dim On/Off Pull dim Absence

dimm.

FDH Finish

2x28 W White 19248 -217 -219 -220 -218

2x28 W Grey 19268 -217 -219 -220 -218

2x35 W White 19249 -217 -219 -220 -218

2x35 W Grey 19269 -217 -219 -220 -218

Loop Light Beta e-Sense

Page 11: FAGERHULT | e-sense

Ten° Line offers an excellent indirect

light contribution which gives high

lighting comfort, ideal when working

with a computer monitor.

Body of sheet steel in a white or

alu-grey structured enamelled fi nish.

e-Sense luminaires are available with

both alu-grey cross-blade louvre or

with double parabolic, Beta-louvre in

satin matt metallized aluminium.

The sensor in the cross-blade design

is placed in the body and in the Beta

design in the louvre’s fi rst cell.

Ten° Line e-Sense

Ten° Line ActiLume SmartSwitch SmartSwitch SmartSwitch

Pull dim On/Off Pull dim Absence

dimm.

FDH Finish

Lamell

3x28 W White 26115 -217 -219 -220 -218

3x28 W Grey 26116 -217 -219 -220 -218

2x35 W White 26123 -217 -219 -220 -218

2x35 W Grey 26124 -217 -219 -220 -218

Beta

3x28 W White 26235 -308 -314 -315 -309

3x28 W Grey 26236 -308 -314 -315 -309

Page 12: FAGERHULT | e-sense

Above is Indigo Combo 1-cell presented wth e-Sense suffi x codes. Indigo Combo is also available with two louvre cells, see main catalogue.

The uncomplicated and clean

recessed design combined with

high effi ciency and technical

performance allows Indigo

Combo to create comfortable

environments.

Combo is available in square

or rectangular designs and in

two sizes with one or two louv-

re cells with up to four light

sources. The active Beta louvre

is combined with indirect light

distribution in the luminaire’s

secondary refl ector. The sensor

unit is placed in the fi rst cell.

Indigo Combo e-Sense

Indigo Combo, 1-cell, for visible T-bars ActiLume SmartSwitch

FDH Absence dimm.

300x1200

1x28 W 24855 -308 -309

2x28 W 24856 -308 -309

1x54 W 24857 -308 -309

600x600

2x14 W 24862 -308 -309

600x1200

1x28 W 24871 -308 -309

2x28 W 24872 -308 -309

1x54 W 24873 -308 -309

Page 13: FAGERHULT | e-sense

Tigris, a luminaire with a clean

design and compact footprint

represents design united with

technology. Developed for offi ce

environments and conference

rooms where a luminaire with

its own style is sought.

Body of sheet steel in white

or alu-grey structured enamel-

led fi nish. Tigris Beta has two

fl uorescent lamps for the up-

light and the third is placed in

a double parabolic, Beta-louvre

in satin matt metallized alumi-

nium. In Tigris the sensor unit is

mounted in the body.

Tigris e-Sense

Tigris Beta ActiLume SmartSwitch SmartSwitch SmartSwitch

FDH Pull dim On/Off Pull dim Absence dimm.

3x28 W 26810 -217 -219 -220 -218

3x35 W 26811 -217 -219 -220 -218

3x54 W 26812 -217 -219 -220 -218

Page 14: FAGERHULT | e-sense

Manual control

Any retractable switch can be connected to the manual light

control, quickly pressing for on/off. While pressing and holding

gives a dimmer function. Pull switch not required for the UK.

IR remote controls IRT 8010 and IRT 8050

A basic remote control for

general use. The units have

only two buttons, one to

switch on/increase the light

level and one to switch off/

reduce the light level. Aim

the transmitter towards the

Acti Lume sensor in the lu-

minaire and adjust the light

level. A holder is provided

so that the remote control

is always kept in the same place. The same control functions are

offered by the transmitter IRT 8050 for fi xed wall installation

(small picture). Handheld remote control Cat. no 86153.

Wall mounted remote control Cat. no 86151.

Programming of additional functions with IRT 8099

The simplicity of the

ActiLume system is based

on the ability to start the

system by pressing the

service button on the sen-

sor. Should you require a

modifi ed function, several

modes can be programmed

with the help of the remote

control IRT 8099. The system

comes with nine pre-pro-

grammed modes for e.g. schools, corridors, etc. The fi rst two are

accessed using the service button, see the left-hand column. Cat.

no 86155.

Detection over a larger area with IRT 8118

An ActiLume sensor placed

in a luminaire approxi-

mately 2.3 m above the fl oor

has a presence detector

with a detection range of

about 5 x 6 metres. If you

wish to detect presence over

a greater area, one or more

detectors type IRT 8118

can be connected to one of

the DALI terminals in the

luminaire. No programming or commissioning is necessary. IRT

8118 is ideally placed in the ceiling, and has a detection area of

approximately 7 x 7 metres. IRT 8118 is only a presence detec-

tor. Cat. no 86152.

Product description

The system consists of

a small, compact sensor

unit and a controller de-

signed for assembly in

the luminaire. ActiLume

is a simple system

produced for “plug and

play” lighting solutions

in offi ce areas. The

combination presence

detector – light sensor

– dimmable HF-ballasts gives a vast range of choices. With

the experience of knowing which combinations are used

the most, you can easily attain the perfect solution for light

control in an offi ce.

To start an ActiLume installation is easy – just connect it!

ActiLume has a factory

setting that automati-

cally sets the lighting

level. However, you

should make your own

setting for the room in

question. NOTE! Avoid

the infl uence of daylight

when doing this.

Press in the service

button for longer than

3 seconds (the fl uorescent lamp fl ashes once). After 30

seconds the adjustment is made (the fl uorescent lamp

fl ashes again). A delay of 30 seconds is used to give time to

move away a ladder or anything else that may obstruct the

normal reading of the work surface with a sensor. ActiLume

adjusts the light level automatically to approximately 80 %

of the new light value. This corresponds to about 600 lux

(500 lux + 0.8 maintenance factor) on the work surface

in an offi ce with the normal placement of the luminaire.

Adjustment to 80% is as the new, maintained, light level

is usually higher than the normal value. You already make

savings with this setting.

You can easily choose one of two standard functions by

pressing the sensor unit's service button (press less than

3 seconds). When the button is released the fl uorescent

lamp indicates by fl ashing once or twice:

Flashing once = “Mode 1” Offi ce (the light is switched off

approximately 15 minutes after last presence detection).

Flashing twice = “Mode 2” Landscape offi ce solution (the

light is adjusted down to a low level after the last presence

detection and is completely switched off 2 hours later).

ActiLume functionality and commissioning

Page 15: FAGERHULT | e-sense

SmartSwitch functionality and commissioning

Product description

SmartSwitch consists of a

small sensor unit and the

combined relay/power sup-

ply. The capacity of the relay

is 200 VA, which means you

can connect one or two HF-

ballasts for ignition/switch-

ing off.

The sensor is a PIR-unit

(Passive Infra Red) with a

detection area of approxi-

mately 4 x 3 metres when the

luminaire is placed at a height of 2.1 metres. Within this area the

sensor detects IR radiation from the body whereby the relay closes

and the lamp in the luminaire comes on.

At the rear of the sensor unit

on SmartSwitch there is also

a setting for the lux level.

This is a threshold value that

prevents the sensor from re-

acting to presence if there is

already suffi cient light in the

room. This setting has been

removed in luminaires with

Pull dim, so that you can al-

ways manually switch on and

switch off in a bright room.

The lux level is more usable with absence dimming. A luminaire

with SmartSwitch only needs to be connected to the mains supply

– it's then ready.

Application areas

SmartSwitch has been developed to suit most offi ce buildings,

individual rooms as well as open offi ce landscapes. Smart Switch is

also ideal for entrances, corridors and small meeting rooms.

SmartSwitch ON/OFF

After the last detection the sensor switches off automati-

cally. The delay can be adjusted between 1 to 30 minutes. You

should not have a shorter switching off delay than 15 minutes.

If the luminaire switches on and off too often, this affects the

life of the fl uorescent lamp.

SmartSwitch ON/OFF has a setting for the lux level, if the

light is suffi cient the lamp is not switched on. e-Sense SmartS-

witch ON/OFF does not feature dimmable HF-ballasts.

SmartSwitch pull dim

Using the pull switch you can easily adjust the light level as

well as switch on and off. This is an advantage especially when

using adjustable desks. In the highest position the light level on

the work surface can be double that of when in sitting position.

The luminaire has a memory for the last setting, which with

detection means that it reignites at the level it was previously

switched off at. The setting for the lux level has been removed

so that you can always switch on and switch off the luminaire

manually using the pull cord even in a bright room.

e-Sense SmartSwitch pull dim is equipped with an ECO lp

device for dimming via the pull switch, one or two switches

depending on the luminaire. The switch provides switching on

and switching off functions as well as manual dimming.

SmartSwitch absence dimming

Control between high/low levels. This function is very much

in demand. there is still a need to adequately light areas of

low presence these include copying rooms, cloakrooms, paper

stores, etc. Frequently switching a luminaire on and off has a

negative affect on the life of the fl uorescent lamp, however,

adjusting between two levels is perfectly acceptable. The

minimum level in the function is set to approximately 10 %,

which gives basic light in the room. When presence is detected

the level is adjusted directly to 100 %. The time delay back to

the low level can be short, about 1-2 minutes. This function

provides the opportunity of major energy savings in rooms with

short periods of presence without jeopardizing the life of the

fl uorescent lamp. Switching off should be controlled centrally

in the system, for example, via a time switch.

The absence dimming function also features a setting for the

lux level, if the light is suffi cient the level is not adjusted.

e-Sense functions ActiLume SmartSwitch SmartSwitch SmartSwitch

On/Off Pull dim Absense dimming

Presence detection

Absense dimming (high/low)

Fixed absense time (15 min)

Adjustable absense time (1–30 min)

Constant light

Automatic setting of lighting level (600 lx)

Lux level setting (50 – 2000 lx)

IR-receiver

Possibility to choose more settings (Modes)

1 pull dim in 2-lamp luminaires

1 pull dim in 3-lamp luminaires

2 pull dim in 3-lamp luminaires (separate direct/indirect)

Offset function 30%

Possibility to control more luminaires (master function)

Page 16: FAGERHULT | e-sense

Fagerhult develops, manufactures and markets

professional lighting systems for public environ-

ments such as offi ces, schools, industries and

hospitals. Our operations are run with a constant

focus on design, function, fl exibility and energy

saving solutions.

Fagerhult is a member of the Fagerhult Group, the

largest lighting group in the Nordic region and a

leading company in Europe. We have sales com-

panies in more than 15 countries and production

units in Europe, China and Australia. In 2007 the

group had sales of SEK 2.5 billion and is listed on

the OMX Nordic Exchange in Stockholm,

Mid Cap list

fagerhult head office sweden

Fagerhults Belysning AB

566 80 Habo

Sweden

Tel +46 36 10 85 00

Fax +46 36 10 86 99

[email protected]

www.fagerhult.com

UNITED KINGDOM

Fagerhult Lighting Ltd

50 Southwark Street

London, SE1 1UN

Tel +44 (0) 207 403 4123

Fax +44 (0) 207 378 0906

[email protected]

www.fagerhult.co.uk

74

3.EX

P.1

.08

.23

.3