3 | Technical Seminar | HVACR Indonesia | October 2014
Cold room Control – Single & Three Phase
Cold Room control can Be donein a number of ways from simple Mechanical Thermostat to high end Electronic controls.
Danfoss offers all of the above,But today we will focus on theElectronic Controls for Single andThree Phase systems.
5 | Technical Seminar | HVACR Indonesia | October 2014
ERC 21x Project Scope
• Introduce a new low-mid end product range to gain market share in the Commercial Refrigeration segment with focus on the following applications:
5│
• Replacing existing EKC102 with a product range having additional features, an
improved usability and more competitive price level
6 | Technical Seminar | HVACR Indonesia | October 2014
Single Phase Solution for Medium & Low Temperature Applications – ERC 21x
Type Description S-PackCode no.
ERC 211 Red LED, 230 V, 1 relay, 1 sensor 080G3263
ERC 213 Red LED, 230 V, 3 relay, 2 sensors 080G3265
A7 Booklet
6 languages(EN, RU, PL, ES, PT, FR)
NTC Sensor10kOhm at 25°C
1,5m cable
ERC 21X
&
Mounting Clip
Kit placed in existing box
Box with
accessory
7 | Technical Seminar | HVACR Indonesia | October 2014
Display Icon and Button Description
Press and hold: Factory reset
Press once : BackPress & hold : Pull down
Press once : Temp set point/OKPress & hold : Menu
Press once : UPPress & hold : ON/OFF
Press once : DOWNPress & hold : Defrost
9 | Technical Seminar | HVACR Indonesia | October 2014
Technical SpecificationsPower Supply
Input
UL60730 EN60730
DO1 (Compressor relay)120 V a.c.: 16 A resistive/FLA16/LRA72240 V a.c.: 10 A resistive/FLA10/LRA60
16 (16) A
DO2 (Defrost/Alarm) 8A resistive, FLA 2 / LRA 12 2 (2) ADO3 (Fan) 3A resistive, FLA 2 / LRA 12 2 (2) ADO4 (Light / Alarm) 2A 2A
Probes
Connectors
Mounting
Display
Keypad
Operating Conditions
Storage conditions
Range of Measurement
Protection
Envirnomental
Resistance to heat & fire Category D (UL94-V0)
Output
4 buttons (integrated IP65 design), user programmable
-10°C to 55°C
-40°C to 105°C, 93% RH
-40°C to 70°C
Front: IP65, Rear: water and dust protection corresponds to IP31, accessibility of connectors limit rear part rating to IP00
Pollution degree II, non-condensing
LED display, 3 digit, decimal point and multi functionality icons; °C/°F scale
115VAC/230VAC 50-60Hz Galvanic isolated low voltage regulated power supply.
4 inputs: 2 analogue, 1 analogue/digital, 1 digital
Compatable with below SensorsNTC 5000 ohm @ 25 °CNTC 10000 ohm @ 25 °CPTC (990 ohm @ 25°C)Pt 1000 (1000 ohm @ 0 °C)
Screw terminal connetors for both input and output connections.
Rear mounting (Insert the controller from front and lock with clips from rear)
10 | Technical Seminar | HVACR Indonesia | October 2014
Easy Menu Structure
- The parameters are structured in
groupswhich makes finding the right
parameter a lot faster.
- We introduced quick installation and
service menus to make installation
and service faster.
- Alphanumeric codes for easy
recognizability
11 | Technical Seminar | HVACR Indonesia | October 2014
Patented
Largest Display in Product ClassERC 21x has a display size of 29X17 cm which is largest among our competitors
Support widest range of sensorsNone of the main competitors support 4 types of Sensors. This gives ERC 21x maximum flexibility in replacement sales
No compromise on accuracy with deviation of+/- 0.5K Between -35 to +25˚C+/- 1K Between -40 to -35˚C +/- 1K Between +25 to 105˚C
Flat Front Design Most of our competitors do not have Flat front Design with clear feedback on button click and no grooves around buttons, which makes it easy to clean and also avoid filth
EU Design
Registration
Longest LifeWith Zero Cross Technology on all relays, ERC 21x’s life increases up to 33% (2 years) longer as compared to competitors
ReliabilityNone of the main competitors protects the compressor by monitoring:- the power supply voltage level- the condenser temperature with 2
levels of alarms
Application Based setupERC 21x has pre configured applications making setup quick and easy
Single Phase Solution for Medium & Low Temperature Applications – ERC 21x
14 | Technical Seminar | HVACR Indonesia | October 2014
AK-RC 101/103 OPTYMA Controller
Single-phase
Three-phase
Three-phase
15 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – single-phase
Transparent cover allows access to the protections
(IP65 rating)
Innovative design
.
.
Circuit breaker accessible from the front panel,
which cuts the general power supply
Control for complete management of refrigeration systems with single-phase compressor up to 1,5 kW (2 HP) and defrost heaters 3 KW
16 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – single-phase
.
Electronic control with wide LED display and easy to use
buttons
Easy installation and opening with new hinged cover
17 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – single-phase
.
..
.
Easy wiring on the internal terminal block with voltage
(230V) outputs
Protection cover for the controller PCB
Sticker for connectionLarge internal space
18 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – three-phase
.
Adjustable motor circuit breaker for compressor protection
accessible from the front panel
Magnetothermic circuit breaker for auxiliary circuits
..
Magnetothermic circuit breaker accessible from the front panel,which cuts the general power
supply
Three-phase systems series for 5,5 kW (7,5HP):Total control of three-phase refrigeration plant up to 5.5 kW, static or ventilated, with off-cycle or electrical defrosting.
• 11 to 16A• 14 to 20A
Three-phase systems series for 3 kW (4 HP):Total control of three-phase refrigeration plant up to 3 kW, static or ventilated, with off-cycle or electrical defrosting.
• 4,5 to 6,3A• 7 to 10A
19 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – three-phase
Contactors for:• Compressor• Defrost• Fan• Light
20 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – spare parts NTC sensor
EKS 221 NTC sensor 3,5m
code no. : 084N3210
IP 67
Tolerance 1%
Ohmic check : 10Kohm / 25 °C
e
EKS 211 NTC sensor 3,5m
code no. : 084B4404
IP 67
Tolerance 1%
Ohmic check : 5Kohm / 25 °C
WARNING !! EKS 211 for EKC 102,202 can not be used !!
21 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – programming
Level 1 – Programming (User Level)To gain access to the Level 1 configuration menu proceed as follows:
1.Press the UP (▲) and DOWN (▼) keys simultaneous and keep them pressed for a few seconds until the first program variable appears on the display.
2.Release the UP (▲) and DOWN (▼) keys.
3.Select the variable to be modified using the UP (▲) and DOWN (▼) keys.
4.When the variable has been selected it is possible to:•display the settings by pressing the SET key •modify the setting by pressing the SET key together with the UP (▲) and DOWN (▼) keys.
When configuration values have been set, you can exit the menu by pressing the UP (▲) and DOWN (▼) keys simultaneous for a few seconds until the cold room temperature appears.
5.The new settings are saved automatically when you exit the configuration menu.
23 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control – programming
Level 2 – Programming (Installer Level)To access to the second level press the UP (▲) and DOWN (▼) keys and the LIGHT key simultaneous for a few seconds.
When the first programming variable appears thesystem automatically goes to stand-by.
1.Select the variable to be modified by pressing the UP (▲) and DOWN (▼) keys. When the parameter has been selected it is possible to:
2.View the setting by pressing the SET key.
3.Modify the setting by holding the SET key down and press the UP (▲) and DOWN (▼) keys.
4.When configuration settings have been completed you can exit the menu by pressing the UP (▲) and DOWN (▼) keys simultaneous and keeping them pressed until the room temperature reappears.
5.Changes are saved automatically when you exit the configuration menu.
6.Press the STAND-BY key to enable electronic control.
30 | Technical Seminar | HVACR Indonesia | October 2014
OPTYMA Control on test application
This nice photo of a test application with OPTYMA Controller and OPTYMA PLUS Condensing unit
This also Clearly shows the OPTYMA controller and Condensing are a Perfect match…!
31 | Technical Seminar | HVACR Indonesia | October 2014
Smart Store Product Portfolio
3rd Party HVAC, Light, Controllers
Evaporator Control
Customized SolutionsBasic Control
Pack Control HVAC, Light, Aux. Control
System Manager StoreViewDesktop
SiteService App Remote Management Tool
Web Browser
Basic
High-End
OPTYMA Controller Mid-RangeHFC
High EndHFC/CO2
I/O ModulesHumidity Sensor
Light Sensor
Energy MeterGas Sensor
Sto
re L
evel
Sto
re L
evel
Chain
Level
Chain
Level
Applic
ation L
evel
Applic
ation L
evel
Act
uato
r/se
nso
rAct
uato
r/se
nso
r
Enterprise ManagerDanfoss Electronically Delivered Services
CO2 Valves
Aux. Components
TXV EEV Sensors Drives
Heat Exchangers
Open XML interface for 3rd party integration
Balancing Valves Condensing Units
Compressors