Upload
ashwani-kumar
View
306
Download
1
Embed Size (px)
Citation preview
321
INDUSTRIAL TRAINING ATNORTHERN RAILWAYS(COACH CARE CENTRE,NZM)
ASHWANI KUMAR (04413304912) ANAND PRAKASH GAUTAM
(00313304912) BHARAT GAUTAM (04913304912) NIKHIL KUMAR RATHI (0501304912) RAHUL RANJAN (04713304912)
History
Organizational Structure
Linke-Hofman & Busch (LHB) Coaches
CONTENTS
• Railways were first introduced to India in 1853 from Bombay to Thane. • In 1951 the systems were nationalized as one unit• Indian state-owned enterprise, owned and operated by the Government of India through the Ministry of Railways.
HISTORY
It is one of the world's largest railway networks comprising 115,000 km (71,000 mi) of track over a route of 65,000 km (40,000 mi) and 7,500 stations.
As of December 2012, it transported over 25 million passengers daily (over 9 billion on an annual basis).
2011, IR carried over 8,900 million passengers annually or more than 24 million passengers daily (roughly half of which were suburban passengers) and 2.8 million tons of freight daily.
2011–2012 Indian Railways had revenues of
Total revenue 1119848.9 million (Us$17 billion)
Freight 696759.7 million (US$11 billion)
Passengers tickets 286455.2 million (US$4.4 billion)
Top •Ministry of railway •Railway board
Middle •16 zones headed by general manager•68 divisions headed by division railway manager
Bottom •Station masters who control individual station
ORGANIZATIONAL STRUCTURE
LHB COACHES
IV COUPLER
EXT.SUPPLY SOCKET
BATTERIES BATTERY FUSE BOX
AC PACKAGE UNIT FRESH AIR INTAKE EXHAUST
FANS
GENERAL FEATURES OF LHB COACH MICRO-PROCESSOR BASED AC PACKAGE INTEGRATED SWITCH BOARD CABINET
INTERVEHICULAR COUPLER (IVC) PANTRY EQUIPMENTS IGBT BASED BATTERY CHARGER EPOXY COATED TRANSFORMER VARIOUS LIGHT FITTINGS MICRO-PROCESSOR BASED PUMP UNIT WHEEL SET EARTHING DEVICE SMF BATTERIES FEEDER JUNCTION BOX DC-DC CONVERTERS
ALTERNATOR
Connection StarGenerated voltage 97V ACRating 4.5kWNo. Of V grooves 4
The alternator is mounted between two wheels. The V belts are attached in the V grooves on the pulley attached to the shaft and the axis of the wheel.
RECTIFIER CUM REGULATOR UNIT (RRU)
Speed Range 550 RPM to 2500 RPMVoltage 124VRating 4.5kWFull Load Current 38A
RRU is connected just beside the alternator to rectify the output of the generator.
The RRU has following functions:
1. To rectify the 3-phase AC output of the alternator through DC full wave bridge rectifier.
2. Regulator the voltage generated by the alternator at the set value.
3. Regulating the output current.
The output of the RRU is given to battery box to charge the battery .
In a non AC coaches a battery box consist of 18 cells(6V/120Ah each) ,In AC coaches 2 battery box 56 cells(2V/1100Ah each) used.
BCT is provided for external charging of the batteries at stations or maintenance lines.
Used Battery in train is VRLA (Valve Regulated Lead Acid) types advantages -
1. Topping up with water is not required.2. Periodical checking of specific gravity is not
required.3. Regular maintenance to avoid sulphation of
terminals and connections not required.
Battery and Battery Charging Terminals: -
110 V , 70 Ah , VRLA BATTERY MAIN FEATURES CONSTRUCTIONAL FEATURES • PURE LEAD -TIN PLATE ( THIN ) • 12 VOLTS BATTERY MODULE • UL 94 V-O NORYL PLASTIC CONTAINER WITH METAL JACKET• M6 (F) NO MAINTENANCE TERMINALS • CAN BE MOUNTED IN ANY ORIENTATION PERFORMANCE FEATURES• WIDE TEMPERATURE RANGE : -40 Deg.C to +55 Degree C• 400 + FULL DEPTH OF DISCHARGE CYCLES • 8+ YEARS FLOAT LIFE @ 25 Degree C• 2 YEARS SHELF LIFE • HIGH DISCHARGE RATE @ 25Degree C• RAPID RECHARGE • DEEP DISCHARGE RECOVERY
110V,70AH VRLA LIGHT WEIGHT BATTERIES
9 MODULES OF 12 VOLTS EACHTOTAL WEIGHT 235 Kgs
Rotary Junction Box is provided inside the coaches.
It is used to arrange and control the power supply to various circuit of the
coaches (e.g. light, fan) with the help of rotary switches and HRC fuses.
4 Rotary switches are connected in Rotary Junction Box:
1. The first switch is used to supply 70% light load in coach.
2. The second switch is used to supply 30% light load in coach.
3. . The third switch is used to supply fan load in coach.
4. The fourth switch is known as EFT switch.
ROTARY JUNCTION BOX
It is provided at the both end of the coach to feed the
additional supply to the adjacent coach in case of emergency.
Supply from the healthy coach may be extended to him/dark
coach by connecting wire(1.5x2 meter) for supply to the
positive and negative terminals of the EFT.
Emergency Feed Terminals (EFT)
ROOF MOUNTED AC PACKAGE UNITCAPACITY
COOLING - 22.5KW ( 6.4 TON ) HEATING - 6.1KW
•POWER INPUT - 17KVA•OPERATING VOLTAGE - 3 PHASE,415V,50HZ•WEIGHT - 630KG•DIMENSIONS - 2330X2000X500•COMPRESSOR - BRISTOL MAKE TYPE H23A 563 DBE
SALIENT FEATURES•NTC TYPE TEMP. SENSORS•SERVO MOTOR CONTROLLED FRESH AIR DAMPERS• MICRO-PROCESSOR CONTROL ( WITH RS232 PORT )•HARTING CONNNECTORS •HUMIDITY CONTROL•CAPACITY CONTROL THROUGH BYPASS SOLENOID VALVE •MOTORS ARE PROTECTED WITH THERMAL SWITCHES•ANALOGUE LP/HP DATA DISPLAY
ROOF MOUNTED AC PACKAGE UNIT
CONDENSOR FANS AIR INTAKE FOR THE CONDENSOR FANS
MCB’S
ANTI-SKID DEVICE
DISCONNECTING AND EARTHING DEVICE
BATTERY CAHRGER
SPACE FOR THE MAIN CONTACTORS
DC DC CONVERTERS
SWITCH BOARD CABINET
SALIENT FEATURES
• CAPABLE OF SWITCHNING , CONTROLLING , ADJUSTING AND MONITORING OF AIR CONDITIONING , PANTRY , LIGHTING , PUMP , SANITARY & ANTI-SKID PROTECTION .
• DIMENSIONS : 1850 ( H ) x 1280 ( W ) x 1040 ( D )
• EASY FRONT ACCESS FOR MAINTENANCE WITH SEPARATE HOUSING FOR BATTERY CHARGER , DISCONNECTING AND EARTHING DEVICES
• SEGREGATION FOR DIFFERENT VOLTAGE LEVELS
• EXTERNALLY VENTILATED
SWITCH BOARD CABINET
400 AMPS INTERVEHICLE COUPLER
IVC PLUG
IVC PLUGHOUSING ( AL. DIE CAST )
MAIN CONTACTS( 400 AMPS ) CONTROL PINS
( 25 AMPS )
TERMINALS
MAIN CABLES
FEEDER JUNCTION BOX
CARBON BRUSH( 20 x 42 x 52 )
COPPERBRAIDED CABLE
BRUSH HOLDER
DETAILED VIEW OF THE CARBON BRUSH
60 KVA TRANSFORMER WITH EPOXY ENCAPSULATION
TERMINAL BOARD
PERFORATED SS HOUSING
MOUNTING ARRGT. WITH AVM’S
• TYPE - EPOXY COATED ENCAPSULATED , WATER PROOF
WINDING
• RATING- 3ø , 50Hz , 60KVA, 750/415V
• INSULATION - CLASS H
• NATURAL AIR COOLED
• WEIGHT - 335KG ( Max.)
• DIMENSIONS - 600X530X626
• DEGREE OF PROTECTION -
IP-21 HOUSING
IP-65 TERMINAL BOX & WINDING
60 KVA TRANSFORMER
WATER PUMP WITH CONTROLLER
WATER LEVEL SENSOR PUMP BOX
• SELF PRIMING MONO BLOCK TYPE MICR-CONTROLLER BASED WITH INFRA-RED SENSOR FOR DRY RUN PROTECTION PUMP• OPERATING VOLTAGE : 3 PHASE,415V+/-5%,50HZ• POWER RATING : 200W (MAX.)• RPM : 2700• DISCHARGE CAPACITY : 10 LPM• WEIGHT : 6.5 KG• PROTECTION : IP-54MICRO-CONTROLLER• INPUT SUPPLY : 24V DC +/-10% WATER LEVEL SENSOR
TYPE OPTICAL LEVEL SENSOR WITH UNMODULATED INFRA-RED TYPE, 24V DC 20 mA HOUSED IN POLYSULPHANE ENCUMBENT
OTHER DETAILS OPERATING AT 0-100 LUX AT 30HZ WITH PRESSURE WITHSTANDING AT 10 BAR AT 60ºC ,INTERFACE PIPE THREADING 3/8”
WATER PUMP WITH MICRO-CONTROLLER AND SENSOR
AIR CONDITIONING SYSTEM
Principle of Operation of the AC System:
LATENT PRINCIPLE
EXPANSION PRINCIPLE
THE REFRIGERATION CYCLE
TYPES
• FLOURESCENT TUBES 18 WATTS
• INCANDESCENT LAMPS 10 WATTS ( FOR NIGHT LIGHT AND PANTRY)
• HALOGEN LAMPS 10 WATTS ( READING LIGHTS )
FLOURESCENT TUBES USED AS GENERAL LIGHTING , VESTIBULE , TOILET , PANTRY
AND EMERGENCY WORKING AT 110 VOLTS AC/DC WITH INVERTER
AND WITH POLYCARBONATE DIFFUSERS
TECHNICAL DATA OF THE INVERTER FOR FL. LAMP ( SIZE - 48x36x252 )
NOMINAL INPUT VOLTAGE 110 V AC/ 50 Hz ( 88 -138 V RANGE )
TECHNICAL DATA OF THE INVERTER FOR READING LIGHTS ( SIZE - 36x31x296 )
NOMINAL INPUT /OUTPUT VOLTAGE 110 V DC / 12 V DC
POWER 0 - 60 W / 12 V
COACH LIGHTING