View
2
Download
0
Category
Preview:
Citation preview
SUBURBAN
SUBSTATION
UNDERGROUND
HIGH SPEED
STATION
URBAN
INTERURBAN
• TechnergyTMRailway & Undergroundcables include a full range ofFire Resistant cables specificallydeveloped for underground linesand tunnels. For human andequipment safety purposes, inthese types of installations,emergency exits and vital lifeguardservices must operate properlyeven under fire conditions, for aminimum time necessary to letpeople out and to permit theintervention of firefighters. Forthese applications, Prysmianoffers a complete range of cables,which exceed the most severefire resistance standards, evenfor communication purposes.
• Prysmian has always been atthe forefront of meeting therequirements of the mostadvanced railway standardswithin the ERTMS (EuropeanRail Traffic Management System)and according to the requirementsof European transportationcompanies, railway designersand installers. New standardsare aimed at creating a singlerailway signalling and controlsystem, which guarantees interoperability throughout theEuropean Rail Network. TheERTMS require high levels ofEMC performance.
TechnergyTMRailway & Undergroundcables are designed and built tocomply with such demanding EMCrequirements and use specialmaterials and screening designs.
• Prysmian has an internationalnetwork of technically skilledsales offices coordinated by theheadquarters, which ensuresthat our customers have a localand easy-to-reach sales andtechnical contact point.
• Full project documentation andtechnical consulting is suppliedto all of our customers as partof our sales support program.
• TechnergyTMRailway & Undergroundcables are available on shortlead times or from stock.
> Fire Resistant Cables
> ERTMS Compliance > Contract Managementand Stock Availability
TRAVELLING IN COMPLETE SAFETY
Furthermore, new cable designs and materials have been developed in order to meet the most demandingrequirements of the Railway and Underground industry.TechnergyTM provides a full range of products that incorporate these railway technologies, including Medium andLow Voltage Power cables, Communication cables, and Control and Signalling cables.
TechnergyTM Railway & Underground cables offer Rail and MTR authorities and operators, contractors,specifiers, system designers and installers the following benefits:
EVEREXHigh Performance Compound INIATURISEDM
SAFETY LINETM
fumex® Application
Benefits
The rapid development of railway technologies in recent years has impacted all areas, from mass transit tohigh-speed lines. The railway systems themselves, from DC to 2x25 kV AC, have undergone a similar evolution.System complexity and reliability, as well as safety, are the key results of this remarkable change.A key effect of these advances is the development of cables with high levels of performance in terms of chemicaland mechanical resistance, fire resistance, EMC behaviour and transmission capacity.
• Durability: TechnergyTM Railway& Underground cables have aproven track record in extendedworking lifetime versus standardrailway cables and need minimummaintenance.
• E0 and easy-stripping compoundsmake installation easier, fasterand - as a result - less expensive.
• Components: Prysmian suppliessets of assembly components, tailor-made to your needs thatsignificantly reduce installationtime.
• Completeness: a comprehensiveproduct range, covering all functionalities (MV/LV, Controland Signalling, Video and DataTransmission, Optical Fibers).
• Railway’s Cable Outfit: TechnergyTM
Railway & Underground cablesare suitable for any power andcommunication system, as wellas signalling andcontrol devices.Prysmian provides cables, such asBOA, EUROBALISE, ENCODER-BOA,ZCO3, for the most demandingand advanced applications.
• Customised Cable Design: Prysmiancan provide cables and compoundstailor-made to specific applications,according to specified customerrequirements (e.g. for extraordinarilyheavy duty and harsh environments).
• Prysmian has always focused itsattention on both human andmaterial safety in all workingconditions. In railway applications,cables are often installed in verycritical conditions such as tunnelsand deep underground lines. Inthis case, it is very important touse cables that under fireconditions, do not increase firerelated hazards and that ensure theproper running of safety devicesunder extreme circumstances.
Under fire conditions the typicallyrequired light transmittance forLSOH cables’ smoke emissionsis not lower than 60%.TechnergyTM
Railway & Underground cablescomply with the highest standards,which establish that smokeemissions must have a lighttransmittance higher than 75%.
RAILWAY & UNDERGROUND
> Lower Total Costof Ownership
> Unique Safetyin Fire Hazard
> OutstandingProduct
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Railway &Underground
Cables
deg
a d
esig
n gr
oupWorld Wide Excellence Center
tel. +33 3 8695 7769, fax +33 3 8695 7781
Head OfficePrysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com
ARGENTINAPrysmian Energía Cables y Sistemasde Argentina S. A.Fábrica La Rosa, Av. da Argentina 67841439 Capital Federaltel. +54 11 46302000fax +54 11 46302100
AUSTRALIAPrysmian Power Cables & SystemsAustralia PTY LTD1 Heathcote RoadLocked Bag 7042, Liverpool Business Centre 1871NSWtel. +61 2 96000 777fax +61 2 96000 747
AUSTRIAPrysmian OEKW GmbHLembockgasse 47A, 1230 Wientel. +43 1 866770fax +43 1 86677109
BRAZILPrysmian Energia Cabos e Sistemas do Brasil S. A.Av. Alexandre de Gusmao 14509110-900 Santo André - SPtel. +55 11 49984000fax +55 11 49984811
CHINAPrysmian Tianjin Cables Co. Ltd.513, Huang He Road, Nankai DistrictTianjin, 300112tel. +86 22 2753 9679fax +86 22 2753 3485
EGYPTPrysmian Cables & Systems8 Abd El Azim Aoudallah st. Hegaz sq.Heliopolis - Cairotel. +20 2 2418557fax +20 2 6381327
FINLANDPrysmian Cables & Systems OyP.O. Box 13FIN-02401 Kirkkonummitel. +358 10 77551fax +358 9 2982204
FRANCEPrysmian Energie Cables et Systèmes France s.a.19, Avenue de la Paix - BP 712Paron - 89100, Sens Cedextel. +33 3 86957769fax +33 3 86957781
GERMANYPrysmian Kabel und Systeme GmbHAustrasse 9996465 Neustadt bei Coburgtel. +49 9568 93 2697fax +49 9568 93 2527
HONG KONGPrysmian Cable Systems Pte. Ltd.Unit A, 18/F, China Overseas Building139 Hennessy RoadWanchai, Hong Kongtel. +85 2 2827 8308fax +85 2 2827 7212
HUNGARYPrysmian MKM Magyar Hungarian CableWorks Co. Ltd.Baràzda u. 38H-1116 Budapesttel. +36 1 3822222fax +36 1 3822202
INDONESIAPT. Prysmian Cables IndonesiaGedung BRI II, Suite 1502Jln. Jend Sudirman No 44-46Jakarta 10210tel. +62 264 351222fax +62 264 351780
ITALYPrysmian Cavi e Sistemi Energia Italia SrlViale Sarca 222, 20126 Milanotel. +39 02 6449 69753fax +39 02 6449 5096
MALAYSIAPrysmian Cable Systems Pte. Ltd.Lot 2 Jalan Kawat 15/18, 40702 Shah AlamSelangor Darul Ehsantel. +60 3 5518 4575fax +60 3 5511 9590
NETHERLANDSPrysmian Cables and Systems B.V.Schieweg 9, 2627 AN Delft P.O. Box 495, 2600 AL DelftThe Netherlandstel. +31 15 260 5260 fax +31 15 261 3808
NEW ZEALANDPrysmian Cables & Systems71 Hugi Johnson Drice, P.O. Box 12162Penrose, Aucklandtel. +64 9 5251260fax +64 9 5251262
NORTH AMERICAPrysmian Cables & Systems North America700 Industrial DriveLexington, SC 29072 - USAtel. +1 803 9511130fax +1 803 9511092
NORWAYPrysmian Kabler og Systmer ASP.O.Box 1384, N - 1401 Skitel. +47 64 915713fax +47 64 915714
ROMANIAPrysmian Cabluri si Sisteme SASoseaua Draganesti, Km. 40500 Slatinatel. +40 49 435699fax +40 49 433484
RUSSIAPrysmian Cables and Systems20/12, Str.1, Podsosenskiy Per.Moscow 105062, Russiatel. +7 095 933 7036fax +7 095 933 7035
SINGAPOREPrysmian Cable Systems Pte. Ltd.No 4 Tuas Avenue 12. 3rd Storey639047 Singaporetel. +65 6862 9866fax +65 6862 9877
SLOVAKIAPrysmian Kablo s.r.oTovarenska 11812 61 Bratislavatel. +421 7 50211111fax +421 7 52961773
SPAINPrysmian Cables y Sistemas S.L.Carretera C-15, Km. 208800 Vilanova i la Geltrú (Barcelona) tel. +34 93 811 6181fax +34 93 811 6011
SWEDENPrysmian Kablar och System AbGustavslundsvägen 141P.O.Box 14147SE-16714 Brommatel. +46 8 260416fax +46 8 260413
TURKEYTurk Prysmian Kablo ve Sistemleri A.S.Buyukdere Caddesi No 11734394 Gayrettepe, Istanbultel. +90 212 3551500fax +90 212 2175810
U.A.E. (Dubai)Prysmian Cabels and Systems Middle EastP.O. Box 72125, Dubai tel. +971 4 345 7870fax +971 4 345 7101
UKPrysmian Cables & Systems LimitedP. O. Box 6Leigh RoadEastleighHampshire, SO50 9YEtel. +44 2380 295555fax +44 2380 295111
SUBURBAN
SUBSTATION
UNDERGROUND
HIGH SPEED
STATION
URBAN
INTERURBAN
• TechnergyTMRailway & Undergroundcables include a full range ofFire Resistant cables specificallydeveloped for underground linesand tunnels. For human andequipment safety purposes, inthese types of installations,emergency exits and vital lifeguardservices must operate properlyeven under fire conditions, for aminimum time necessary to letpeople out and to permit theintervention of firefighters. Forthese applications, Prysmianoffers a complete range of cables,which exceed the most severefire resistance standards, evenfor communication purposes.
• Prysmian has always been atthe forefront of meeting therequirements of the mostadvanced railway standardswithin the ERTMS (EuropeanRail Traffic Management System)and according to the requirementsof European transportationcompanies, railway designersand installers. New standardsare aimed at creating a singlerailway signalling and controlsystem, which guarantees interoperability throughout theEuropean Rail Network. TheERTMS require high levels ofEMC performance.
TechnergyTMRailway & Undergroundcables are designed and built tocomply with such demanding EMCrequirements and use specialmaterials and screening designs.
• Prysmian has an internationalnetwork of technically skilledsales offices coordinated by theheadquarters, which ensuresthat our customers have a localand easy-to-reach sales andtechnical contact point.
• Full project documentation andtechnical consulting is suppliedto all of our customers as partof our sales support program.
• TechnergyTMRailway & Undergroundcables are available on shortlead times or from stock.
> Fire Resistant Cables
> ERTMS Compliance > Contract Managementand Stock Availability
TRAVELLING IN COMPLETE SAFETY
Furthermore, new cable designs and materials have been developed in order to meet the most demandingrequirements of the Railway and Underground industry.TechnergyTM provides a full range of products that incorporate these railway technologies, including Medium andLow Voltage Power cables, Communication cables, and Control and Signalling cables.
TechnergyTM Railway & Underground cables offer Rail and MTR authorities and operators, contractors,specifiers, system designers and installers the following benefits:
EVEREXHigh Performance Compound INIATURISEDM
SAFETY LINETM
fumex® Application
Benefits
The rapid development of railway technologies in recent years has impacted all areas, from mass transit tohigh-speed lines. The railway systems themselves, from DC to 2x25 kV AC, have undergone a similar evolution.System complexity and reliability, as well as safety, are the key results of this remarkable change.A key effect of these advances is the development of cables with high levels of performance in terms of chemicaland mechanical resistance, fire resistance, EMC behaviour and transmission capacity.
• Durability: TechnergyTM Railway& Underground cables have aproven track record in extendedworking lifetime versus standardrailway cables and need minimummaintenance.
• E0 and easy-stripping compoundsmake installation easier, fasterand - as a result - less expensive.
• Components: Prysmian suppliessets of assembly components, tailor-made to your needs thatsignificantly reduce installationtime.
• Completeness: a comprehensiveproduct range, covering all functionalities (MV/LV, Controland Signalling, Video and DataTransmission, Optical Fibers).
• Railway’s Cable Outfit: TechnergyTM
Railway & Underground cablesare suitable for any power andcommunication system, as wellas signalling andcontrol devices.Prysmian provides cables, such asBOA, EUROBALISE, ENCODER-BOA,ZCO3, for the most demandingand advanced applications.
• Customised Cable Design: Prysmiancan provide cables and compoundstailor-made to specific applications,according to specified customerrequirements (e.g. for extraordinarilyheavy duty and harsh environments).
• Prysmian has always focused itsattention on both human andmaterial safety in all workingconditions. In railway applications,cables are often installed in verycritical conditions such as tunnelsand deep underground lines. Inthis case, it is very important touse cables that under fireconditions, do not increase firerelated hazards and that ensure theproper running of safety devicesunder extreme circumstances.
Under fire conditions the typicallyrequired light transmittance forLSOH cables’ smoke emissionsis not lower than 60%.TechnergyTM
Railway & Underground cablescomply with the highest standards,which establish that smokeemissions must have a lighttransmittance higher than 75%.
RAILWAY & UNDERGROUND
> Lower Total Costof Ownership
> Unique Safetyin Fire Hazard
> OutstandingProduct
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Railway &Underground
Cables
deg
a d
esig
n gr
oupWorld Wide Excellence Center
tel. +33 3 8695 7769, fax +33 3 8695 7781
Head OfficePrysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com
ARGENTINAPrysmian Energía Cables y Sistemasde Argentina S. A.Fábrica La Rosa, Av. da Argentina 67841439 Capital Federaltel. +54 11 46302000fax +54 11 46302100
AUSTRALIAPrysmian Power Cables & SystemsAustralia PTY LTD1 Heathcote RoadLocked Bag 7042, Liverpool Business Centre 1871NSWtel. +61 2 96000 777fax +61 2 96000 747
AUSTRIAPrysmian OEKW GmbHLembockgasse 47A, 1230 Wientel. +43 1 866770fax +43 1 86677109
BRAZILPrysmian Energia Cabos e Sistemas do Brasil S. A.Av. Alexandre de Gusmao 14509110-900 Santo André - SPtel. +55 11 49984000fax +55 11 49984811
CHINAPrysmian Tianjin Cables Co. Ltd.513, Huang He Road, Nankai DistrictTianjin, 300112tel. +86 22 2753 9679fax +86 22 2753 3485
EGYPTPrysmian Cables & Systems8 Abd El Azim Aoudallah st. Hegaz sq.Heliopolis - Cairotel. +20 2 2418557fax +20 2 6381327
FINLANDPrysmian Cables & Systems OyP.O. Box 13FIN-02401 Kirkkonummitel. +358 10 77551fax +358 9 2982204
FRANCEPrysmian Energie Cables et Systèmes France s.a.19, Avenue de la Paix - BP 712Paron - 89100, Sens Cedextel. +33 3 86957769fax +33 3 86957781
GERMANYPrysmian Kabel und Systeme GmbHAustrasse 9996465 Neustadt bei Coburgtel. +49 9568 93 2697fax +49 9568 93 2527
HONG KONGPrysmian Cable Systems Pte. Ltd.Unit A, 18/F, China Overseas Building139 Hennessy RoadWanchai, Hong Kongtel. +85 2 2827 8308fax +85 2 2827 7212
HUNGARYPrysmian MKM Magyar Hungarian CableWorks Co. Ltd.Baràzda u. 38H-1116 Budapesttel. +36 1 3822222fax +36 1 3822202
INDONESIAPT. Prysmian Cables IndonesiaGedung BRI II, Suite 1502Jln. Jend Sudirman No 44-46Jakarta 10210tel. +62 264 351222fax +62 264 351780
ITALYPrysmian Cavi e Sistemi Energia Italia SrlViale Sarca 222, 20126 Milanotel. +39 02 6449 69753fax +39 02 6449 5096
MALAYSIAPrysmian Cable Systems Pte. Ltd.Lot 2 Jalan Kawat 15/18, 40702 Shah AlamSelangor Darul Ehsantel. +60 3 5518 4575fax +60 3 5511 9590
NETHERLANDSPrysmian Cables and Systems B.V.Schieweg 9, 2627 AN Delft P.O. Box 495, 2600 AL DelftThe Netherlandstel. +31 15 260 5260 fax +31 15 261 3808
NEW ZEALANDPrysmian Cables & Systems71 Hugi Johnson Drice, P.O. Box 12162Penrose, Aucklandtel. +64 9 5251260fax +64 9 5251262
NORTH AMERICAPrysmian Cables & Systems North America700 Industrial DriveLexington, SC 29072 - USAtel. +1 803 9511130fax +1 803 9511092
NORWAYPrysmian Kabler og Systmer ASP.O.Box 1384, N - 1401 Skitel. +47 64 915713fax +47 64 915714
ROMANIAPrysmian Cabluri si Sisteme SASoseaua Draganesti, Km. 40500 Slatinatel. +40 49 435699fax +40 49 433484
RUSSIAPrysmian Cables and Systems20/12, Str.1, Podsosenskiy Per.Moscow 105062, Russiatel. +7 095 933 7036fax +7 095 933 7035
SINGAPOREPrysmian Cable Systems Pte. Ltd.No 4 Tuas Avenue 12. 3rd Storey639047 Singaporetel. +65 6862 9866fax +65 6862 9877
SLOVAKIAPrysmian Kablo s.r.oTovarenska 11812 61 Bratislavatel. +421 7 50211111fax +421 7 52961773
SPAINPrysmian Cables y Sistemas S.L.Carretera C-15, Km. 208800 Vilanova i la Geltrú (Barcelona) tel. +34 93 811 6181fax +34 93 811 6011
SWEDENPrysmian Kablar och System AbGustavslundsvägen 141P.O.Box 14147SE-16714 Brommatel. +46 8 260416fax +46 8 260413
TURKEYTurk Prysmian Kablo ve Sistemleri A.S.Buyukdere Caddesi No 11734394 Gayrettepe, Istanbultel. +90 212 3551500fax +90 212 2175810
U.A.E. (Dubai)Prysmian Cabels and Systems Middle EastP.O. Box 72125, Dubai tel. +971 4 345 7870fax +971 4 345 7101
UKPrysmian Cables & Systems LimitedP. O. Box 6Leigh RoadEastleighHampshire, SO50 9YEtel. +44 2380 295555fax +44 2380 295111
SUBURBAN
SUBSTATION
UNDERGROUND
HIGH SPEED
STATION
URBAN
INTERURBAN
• TechnergyTMRailway & Undergroundcables include a full range ofFire Resistant cables specificallydeveloped for underground linesand tunnels. For human andequipment safety purposes, inthese types of installations,emergency exits and vital lifeguardservices must operate properlyeven under fire conditions, for aminimum time necessary to letpeople out and to permit theintervention of firefighters. Forthese applications, Prysmianoffers a complete range of cables,which exceed the most severefire resistance standards, evenfor communication purposes.
• Prysmian has always been atthe forefront of meeting therequirements of the mostadvanced railway standardswithin the ERTMS (EuropeanRail Traffic Management System)and according to the requirementsof European transportationcompanies, railway designersand installers. New standardsare aimed at creating a singlerailway signalling and controlsystem, which guarantees interoperability throughout theEuropean Rail Network. TheERTMS require high levels ofEMC performance.
TechnergyTMRailway & Undergroundcables are designed and built tocomply with such demanding EMCrequirements and use specialmaterials and screening designs.
• Prysmian has an internationalnetwork of technically skilledsales offices coordinated by theheadquarters, which ensuresthat our customers have a localand easy-to-reach sales andtechnical contact point.
• Full project documentation andtechnical consulting is suppliedto all of our customers as partof our sales support program.
• TechnergyTMRailway & Undergroundcables are available on shortlead times or from stock.
> Fire Resistant Cables
> ERTMS Compliance > Contract Managementand Stock Availability
TRAVELLING IN COMPLETE SAFETY
Furthermore, new cable designs and materials have been developed in order to meet the most demandingrequirements of the Railway and Underground industry.TechnergyTM provides a full range of products that incorporate these railway technologies, including Medium andLow Voltage Power cables, Communication cables, and Control and Signalling cables.
TechnergyTM Railway & Underground cables offer Rail and MTR authorities and operators, contractors,specifiers, system designers and installers the following benefits:
EVEREXHigh Performance Compound INIATURISEDM
SAFETY LINETM
fumex® Application
Benefits
The rapid development of railway technologies in recent years has impacted all areas, from mass transit tohigh-speed lines. The railway systems themselves, from DC to 2x25 kV AC, have undergone a similar evolution.System complexity and reliability, as well as safety, are the key results of this remarkable change.A key effect of these advances is the development of cables with high levels of performance in terms of chemicaland mechanical resistance, fire resistance, EMC behaviour and transmission capacity.
• Durability: TechnergyTM Railway& Underground cables have aproven track record in extendedworking lifetime versus standardrailway cables and need minimummaintenance.
• E0 and easy-stripping compoundsmake installation easier, fasterand - as a result - less expensive.
• Components: Prysmian suppliessets of assembly components, tailor-made to your needs thatsignificantly reduce installationtime.
• Completeness: a comprehensiveproduct range, covering all functionalities (MV/LV, Controland Signalling, Video and DataTransmission, Optical Fibers).
• Railway’s Cable Outfit: TechnergyTM
Railway & Underground cablesare suitable for any power andcommunication system, as wellas signalling andcontrol devices.Prysmian provides cables, such asBOA, EUROBALISE, ENCODER-BOA,ZCO3, for the most demandingand advanced applications.
• Customised Cable Design: Prysmiancan provide cables and compoundstailor-made to specific applications,according to specified customerrequirements (e.g. for extraordinarilyheavy duty and harsh environments).
• Prysmian has always focused itsattention on both human andmaterial safety in all workingconditions. In railway applications,cables are often installed in verycritical conditions such as tunnelsand deep underground lines. Inthis case, it is very important touse cables that under fireconditions, do not increase firerelated hazards and that ensure theproper running of safety devicesunder extreme circumstances.
Under fire conditions the typicallyrequired light transmittance forLSOH cables’ smoke emissionsis not lower than 60%.TechnergyTM
Railway & Underground cablescomply with the highest standards,which establish that smokeemissions must have a lighttransmittance higher than 75%.
RAILWAY & UNDERGROUND
> Lower Total Costof Ownership
> Unique Safetyin Fire Hazard
> OutstandingProduct
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Railway &Underground
Cables
deg
a d
esig
n gr
oupWorld Wide Excellence Center
tel. +33 3 8695 7769, fax +33 3 8695 7781
Head OfficePrysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com
ARGENTINAPrysmian Energía Cables y Sistemasde Argentina S. A.Fábrica La Rosa, Av. da Argentina 67841439 Capital Federaltel. +54 11 46302000fax +54 11 46302100
AUSTRALIAPrysmian Power Cables & SystemsAustralia PTY LTD1 Heathcote RoadLocked Bag 7042, Liverpool Business Centre 1871NSWtel. +61 2 96000 777fax +61 2 96000 747
AUSTRIAPrysmian OEKW GmbHLembockgasse 47A, 1230 Wientel. +43 1 866770fax +43 1 86677109
BRAZILPrysmian Energia Cabos e Sistemas do Brasil S. A.Av. Alexandre de Gusmao 14509110-900 Santo André - SPtel. +55 11 49984000fax +55 11 49984811
CHINAPrysmian Tianjin Cables Co. Ltd.513, Huang He Road, Nankai DistrictTianjin, 300112tel. +86 22 2753 9679fax +86 22 2753 3485
EGYPTPrysmian Cables & Systems8 Abd El Azim Aoudallah st. Hegaz sq.Heliopolis - Cairotel. +20 2 2418557fax +20 2 6381327
FINLANDPrysmian Cables & Systems OyP.O. Box 13FIN-02401 Kirkkonummitel. +358 10 77551fax +358 9 2982204
FRANCEPrysmian Energie Cables et Systèmes France s.a.19, Avenue de la Paix - BP 712Paron - 89100, Sens Cedextel. +33 3 86957769fax +33 3 86957781
GERMANYPrysmian Kabel und Systeme GmbHAustrasse 9996465 Neustadt bei Coburgtel. +49 9568 93 2697fax +49 9568 93 2527
HONG KONGPrysmian Cable Systems Pte. Ltd.Unit A, 18/F, China Overseas Building139 Hennessy RoadWanchai, Hong Kongtel. +85 2 2827 8308fax +85 2 2827 7212
HUNGARYPrysmian MKM Magyar Hungarian CableWorks Co. Ltd.Baràzda u. 38H-1116 Budapesttel. +36 1 3822222fax +36 1 3822202
INDONESIAPT. Prysmian Cables IndonesiaGedung BRI II, Suite 1502Jln. Jend Sudirman No 44-46Jakarta 10210tel. +62 264 351222fax +62 264 351780
ITALYPrysmian Cavi e Sistemi Energia Italia SrlViale Sarca 222, 20126 Milanotel. +39 02 6449 69753fax +39 02 6449 5096
MALAYSIAPrysmian Cable Systems Pte. Ltd.Lot 2 Jalan Kawat 15/18, 40702 Shah AlamSelangor Darul Ehsantel. +60 3 5518 4575fax +60 3 5511 9590
NETHERLANDSPrysmian Cables and Systems B.V.Schieweg 9, 2627 AN Delft P.O. Box 495, 2600 AL DelftThe Netherlandstel. +31 15 260 5260 fax +31 15 261 3808
NEW ZEALANDPrysmian Cables & Systems71 Hugi Johnson Drice, P.O. Box 12162Penrose, Aucklandtel. +64 9 5251260fax +64 9 5251262
NORTH AMERICAPrysmian Cables & Systems North America700 Industrial DriveLexington, SC 29072 - USAtel. +1 803 9511130fax +1 803 9511092
NORWAYPrysmian Kabler og Systmer ASP.O.Box 1384, N - 1401 Skitel. +47 64 915713fax +47 64 915714
ROMANIAPrysmian Cabluri si Sisteme SASoseaua Draganesti, Km. 40500 Slatinatel. +40 49 435699fax +40 49 433484
RUSSIAPrysmian Cables and Systems20/12, Str.1, Podsosenskiy Per.Moscow 105062, Russiatel. +7 095 933 7036fax +7 095 933 7035
SINGAPOREPrysmian Cable Systems Pte. Ltd.No 4 Tuas Avenue 12. 3rd Storey639047 Singaporetel. +65 6862 9866fax +65 6862 9877
SLOVAKIAPrysmian Kablo s.r.oTovarenska 11812 61 Bratislavatel. +421 7 50211111fax +421 7 52961773
SPAINPrysmian Cables y Sistemas S.L.Carretera C-15, Km. 208800 Vilanova i la Geltrú (Barcelona) tel. +34 93 811 6181fax +34 93 811 6011
SWEDENPrysmian Kablar och System AbGustavslundsvägen 141P.O.Box 14147SE-16714 Brommatel. +46 8 260416fax +46 8 260413
TURKEYTurk Prysmian Kablo ve Sistemleri A.S.Buyukdere Caddesi No 11734394 Gayrettepe, Istanbultel. +90 212 3551500fax +90 212 2175810
U.A.E. (Dubai)Prysmian Cabels and Systems Middle EastP.O. Box 72125, Dubai tel. +971 4 345 7870fax +971 4 345 7101
UKPrysmian Cables & Systems LimitedP. O. Box 6Leigh RoadEastleighHampshire, SO50 9YEtel. +44 2380 295555fax +44 2380 295111
Single core medium voltage cables 1.8 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - 1,8 kV
TERAIL
POWER COMMUNICATION Multicore cables
General signalling system, detection and survey.
TERAIL - S - M
General Description
Use
Multicore cables Armoured
General signalling system, detection and survey when mechanical protection is required.
TERAIL - S - MA
General Description
Use
Unscreened (T) multipair cables Armoured
General signalling system when mechanical protection is required.
TERAIL - S - TA
General Description
Use
Screened (T) mutlipair and multiquad cables with (X) anti-inductive Armour
Signalling system in lines with 25 kV rated voltage and "high speed lines".
TERAIL - S - TSAX
General Description
Use
Flexible Multicore cables
Cabling of indoor equipment of signalling circuits.
TERAIL - S - FM
General Description
Use
Screened Flexible Multicore cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FMS
General Description
Use
Flexible (T) multipair cables
Cabling of signalling circuits, indoor equipment.
TERAIL - S - FT
General Description
Use
Screened Flexible (T) multipair cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FTS
General Description
Use
Fire Resistant signalling cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - S - FR
General Description
Use
SIGNALLING TERAIL
SIGNALLING CABLES TERAIL
COMMUNICATION CABLES
General Description
Use
Multicore medium voltage cables 1.8/3 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - M3 kV
General Description
Use
Single core medium voltage cables 25 kV
Power cabling with special fire performance used for track side aerial lines.
TERAIL - P - 25 kV
General Description
Use
Multicore low voltage cables 0.6/1 kV
Power cables used for lighting and low voltage circuits.
TERAIL - P - M
General Description
Use
Multicore medium voltage cables 3.6/6 kV
Power cables for the supply of signalling and auxiliary circuits.
TERAIL - P - M6 kV
General Description
Use
Single core low voltage cables 0.45/0.75 kV
Power flexible cables for equipment and rail track connections.
TERAIL - P - 0,75 kV
General Description
Use
Fire Resistant Power cables adapted to provide all services listed above
Fire hazard safety systems for general indoor use.
TERAIL - P - FR
General Description
Use
Screened (T) multipair and multiquads cables Armoured
Cabling of line and local Telecommunication systems.
TERAIL - C - TSA
General Description
Use
Screened (T) multipair and multiquad cables
Cabling of local Telecommunication systems.
TERAIL - C - TS
General Description
Use
75 Ohm COAXial cable
Video communication systems.
TERAIL - C - COAX
General Description
Use
Single mode and multi mode OPTICal fiber cables
High bit-rate data transmission with dangerous EMC conditions and long distance connections.
TERAIL - C - OPTIC
General Description
Use
Fire Resistant communication cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - C - FR
General Description
Use
POWER CABLES
Prysmian Cables & Systems is a world-classmultinational company. Founded in 1872 as “DittaPirelli & C.”, it has achieved a leading position formore than a century of operations in its two keyinternational markets - ”Energy Cables & Systems”and ”Telecom Cables & Systems”.
Prysmian Cables and Systems is the world’s largestmanufacturer of power and telecommunicationscables, with 52 manufacturing facilities in 21 countriesin five continents and a market share in excess of 10%.
Prysmian Energy Cables and Systems is a globalsolutions provider, offering a wide range ofintegrated solutions, such as cable systems,system design and engineering, project management,installation and post-sale services.
Prysmian Energy Cables and Systems concentrateson continuous product innovation and on achievinga competitive edge by focusing on research anddevelopment. This is done through Prysmian’s ownR&D centres and by co-operating with universities,scientific institutions and above all, our customers.Prysmian’s world-wide organisation makes anddelivers advanced technological solutions tocustomers anywhere in the world.
Prysmian’s TECHNERGY integrated cabling solutionsTM
is one of the world’s most comprehensiveand technologically advanced answers to industry,infrastructure, contractors and OEM’s specificrequirements.
TECHNERGY integrated cabling solutionsTM are designedand structured into twelve different product lines. Eachof these offer tailored designs and added value solutionsto the most diverse functional and environmentalrequirements in the following fields:
> Trains > Cranes & Mobile Equipments
> Marine > Electro-Mechanical
> Oil & Gas > Data & Communication
> Plant & Petrochem > Transportation Infrastuctures
> Mining & Tunnelling > Building & Civil Engineering
> Defence > Power Plants
To find out more about the TECHNERGY integratedcabling solutionsTM, Prysmian Cables and Systemsinvites you to visit the web site: www.prysmian.com
About us Cable families at a glance
RAILWAY & UNDERGROUND TRAVELLING IN COMPLETE SAFETY
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Prysmian has a built in, multi-step quality assuranceprogram, covering the production process from cabledesign and raw material purchasing to final inspectionand testing documentation.
The quality control system of Prysmian has beenassessed and approved and is audited regularly byLloyd's Register of Quality Assurance to the ISO9001 and ISO 14001 Quality System Standards.
The ISO 14001 is the environment quality standard.
Prysmian's TechnergyTM cable factories have approvalsfor their cables at:
> APPROVALSATM - Ferrovie dello StatoMetropolitana MilaneseRail Track - RATP - SNCF
Prysmian works closely with major classification societies.
Qualitycommitment
Accessoriesand modular systems
Referencesproject
Today's industrial world recognises the importance of“system solutions” in many areas. A system gives morethan raw materials alone: it gives benefits and addedvalue that mean competitive advantage. Traditionalinstallation methods for tunnels, bridges and streetlighting involve a considerable amount of on-siteconnection work through the preparation of terminationboxes or cable joints.
LIGHTING MODULAR SYSTEMFlexoTM modular power cable systems have integralsocket outlets, which are factory produced throughoutthe length of the main supply cable. This allows simpleplug-in connections that remove the need for junctionboxes and time-consuming on-site glanding andtermination. The plug leads can be connected to thelights prior to their being secured. The main cablesystem, with integrated sockets, supplied on standarddrums can then be installed as simply as a cable. Wheninstalled, the sockets align with the light fittings andconnections are made by a simple plug-in action.
BENEFITS> Cost
Installation cost savings of up 30%> Speed
Typically 250m can be installed in only 90 minutes> Skill
Reduced skill requirement for plug-in connections> Flexibility
Selectable phase loading easily achieved> Accuracy
Right first time, every time, guaranteed> Reliability
Factory produced and tested to ensure highestquality connections
> SimplicityMaintenance free, simple light fitting replacement
Project Customer CountryAlta Velocità,(Tratta Roma-Napoli) Ansaldo, Alstom ItalyCTRL(High Speed London-Channel) CSEE U.K.Eurotunnel Eurotunnel France, U.K.LUL Central Line Westinghouse U.K.LUL Northern Line LUL U.K.Metro Milano ATM ItalyMetro Napoli Ansaldo, Italtel ItalyMTR North-East Line Singapore Technology SingaporeMTRC Hong Kong Matra Transport Hong KongOslo Metro Westinghouse NorwayRailways Mexico Matra International MexicoTram Lisbonne CSEE Portugal
EVEREXHigh Performance Compound
SAFETY LINETM
Single core medium voltage cables 1.8 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - 1,8 kV
TERAIL
POWER COMMUNICATION Multicore cables
General signalling system, detection and survey.
TERAIL - S - M
General Description
Use
Multicore cables Armoured
General signalling system, detection and survey when mechanical protection is required.
TERAIL - S - MA
General Description
Use
Unscreened (T) multipair cables Armoured
General signalling system when mechanical protection is required.
TERAIL - S - TA
General Description
Use
Screened (T) mutlipair and multiquad cables with (X) anti-inductive Armour
Signalling system in lines with 25 kV rated voltage and "high speed lines".
TERAIL - S - TSAX
General Description
Use
Flexible Multicore cables
Cabling of indoor equipment of signalling circuits.
TERAIL - S - FM
General Description
Use
Screened Flexible Multicore cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FMS
General Description
Use
Flexible (T) multipair cables
Cabling of signalling circuits, indoor equipment.
TERAIL - S - FT
General Description
Use
Screened Flexible (T) multipair cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FTS
General Description
Use
Fire Resistant signalling cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - S - FR
General Description
Use
SIGNALLING TERAIL
SIGNALLING CABLES TERAIL
COMMUNICATION CABLES
General Description
Use
Multicore medium voltage cables 1.8/3 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - M3 kV
General Description
Use
Single core medium voltage cables 25 kV
Power cabling with special fire performance used for track side aerial lines.
TERAIL - P - 25 kV
General Description
Use
Multicore low voltage cables 0.6/1 kV
Power cables used for lighting and low voltage circuits.
TERAIL - P - M
General Description
Use
Multicore medium voltage cables 3.6/6 kV
Power cables for the supply of signalling and auxiliary circuits.
TERAIL - P - M6 kV
General Description
Use
Single core low voltage cables 0.45/0.75 kV
Power flexible cables for equipment and rail track connections.
TERAIL - P - 0,75 kV
General Description
Use
Fire Resistant Power cables adapted to provide all services listed above
Fire hazard safety systems for general indoor use.
TERAIL - P - FR
General Description
Use
Screened (T) multipair and multiquads cables Armoured
Cabling of line and local Telecommunication systems.
TERAIL - C - TSA
General Description
Use
Screened (T) multipair and multiquad cables
Cabling of local Telecommunication systems.
TERAIL - C - TS
General Description
Use
75 Ohm COAXial cable
Video communication systems.
TERAIL - C - COAX
General Description
Use
Single mode and multi mode OPTICal fiber cables
High bit-rate data transmission with dangerous EMC conditions and long distance connections.
TERAIL - C - OPTIC
General Description
Use
Fire Resistant communication cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - C - FR
General Description
Use
POWER CABLES
Prysmian Cables & Systems is a world-classmultinational company. Founded in 1872 as “DittaPirelli & C.”, it has achieved a leading position formore than a century of operations in its two keyinternational markets - ”Energy Cables & Systems”and ”Telecom Cables & Systems”.
Prysmian Cables and Systems is the world’s largestmanufacturer of power and telecommunicationscables, with 52 manufacturing facilities in 21 countriesin five continents and a market share in excess of 10%.
Prysmian Energy Cables and Systems is a globalsolutions provider, offering a wide range ofintegrated solutions, such as cable systems,system design and engineering, project management,installation and post-sale services.
Prysmian Energy Cables and Systems concentrateson continuous product innovation and on achievinga competitive edge by focusing on research anddevelopment. This is done through Prysmian’s ownR&D centres and by co-operating with universities,scientific institutions and above all, our customers.Prysmian’s world-wide organisation makes anddelivers advanced technological solutions tocustomers anywhere in the world.
Prysmian’s TECHNERGY integrated cabling solutionsTM
is one of the world’s most comprehensiveand technologically advanced answers to industry,infrastructure, contractors and OEM’s specificrequirements.
TECHNERGY integrated cabling solutionsTM are designedand structured into twelve different product lines. Eachof these offer tailored designs and added value solutionsto the most diverse functional and environmentalrequirements in the following fields:
> Trains > Cranes & Mobile Equipments
> Marine > Electro-Mechanical
> Oil & Gas > Data & Communication
> Plant & Petrochem > Transportation Infrastuctures
> Mining & Tunnelling > Building & Civil Engineering
> Defence > Power Plants
To find out more about the TECHNERGY integratedcabling solutionsTM, Prysmian Cables and Systemsinvites you to visit the web site: www.prysmian.com
About us Cable families at a glance
RAILWAY & UNDERGROUND TRAVELLING IN COMPLETE SAFETY
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Prysmian has a built in, multi-step quality assuranceprogram, covering the production process from cabledesign and raw material purchasing to final inspectionand testing documentation.
The quality control system of Prysmian has beenassessed and approved and is audited regularly byLloyd's Register of Quality Assurance to the ISO9001 and ISO 14001 Quality System Standards.
The ISO 14001 is the environment quality standard.
Prysmian's TechnergyTM cable factories have approvalsfor their cables at:
> APPROVALSATM - Ferrovie dello StatoMetropolitana MilaneseRail Track - RATP - SNCF
Prysmian works closely with major classification societies.
Qualitycommitment
Accessoriesand modular systems
Referencesproject
Today's industrial world recognises the importance of“system solutions” in many areas. A system gives morethan raw materials alone: it gives benefits and addedvalue that mean competitive advantage. Traditionalinstallation methods for tunnels, bridges and streetlighting involve a considerable amount of on-siteconnection work through the preparation of terminationboxes or cable joints.
LIGHTING MODULAR SYSTEMFlexoTM modular power cable systems have integralsocket outlets, which are factory produced throughoutthe length of the main supply cable. This allows simpleplug-in connections that remove the need for junctionboxes and time-consuming on-site glanding andtermination. The plug leads can be connected to thelights prior to their being secured. The main cablesystem, with integrated sockets, supplied on standarddrums can then be installed as simply as a cable. Wheninstalled, the sockets align with the light fittings andconnections are made by a simple plug-in action.
BENEFITS> Cost
Installation cost savings of up 30%> Speed
Typically 250m can be installed in only 90 minutes> Skill
Reduced skill requirement for plug-in connections> Flexibility
Selectable phase loading easily achieved> Accuracy
Right first time, every time, guaranteed> Reliability
Factory produced and tested to ensure highestquality connections
> SimplicityMaintenance free, simple light fitting replacement
Project Customer CountryAlta Velocità,(Tratta Roma-Napoli) Ansaldo, Alstom ItalyCTRL(High Speed London-Channel) CSEE U.K.Eurotunnel Eurotunnel France, U.K.LUL Central Line Westinghouse U.K.LUL Northern Line LUL U.K.Metro Milano ATM ItalyMetro Napoli Ansaldo, Italtel ItalyMTR North-East Line Singapore Technology SingaporeMTRC Hong Kong Matra Transport Hong KongOslo Metro Westinghouse NorwayRailways Mexico Matra International MexicoTram Lisbonne CSEE Portugal
EVEREXHigh Performance Compound
SAFETY LINETM
Single core medium voltage cables 1.8 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - 1,8 kV
TERAIL
POWER COMMUNICATION Multicore cables
General signalling system, detection and survey.
TERAIL - S - M
General Description
Use
Multicore cables Armoured
General signalling system, detection and survey when mechanical protection is required.
TERAIL - S - MA
General Description
Use
Unscreened (T) multipair cables Armoured
General signalling system when mechanical protection is required.
TERAIL - S - TA
General Description
Use
Screened (T) mutlipair and multiquad cables with (X) anti-inductive Armour
Signalling system in lines with 25 kV rated voltage and "high speed lines".
TERAIL - S - TSAX
General Description
Use
Flexible Multicore cables
Cabling of indoor equipment of signalling circuits.
TERAIL - S - FM
General Description
Use
Screened Flexible Multicore cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FMS
General Description
Use
Flexible (T) multipair cables
Cabling of signalling circuits, indoor equipment.
TERAIL - S - FT
General Description
Use
Screened Flexible (T) multipair cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FTS
General Description
Use
Fire Resistant signalling cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - S - FR
General Description
Use
SIGNALLING TERAIL
SIGNALLING CABLES TERAIL
COMMUNICATION CABLES
General Description
Use
Multicore medium voltage cables 1.8/3 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - M3 kV
General Description
Use
Single core medium voltage cables 25 kV
Power cabling with special fire performance used for track side aerial lines.
TERAIL - P - 25 kV
General Description
Use
Multicore low voltage cables 0.6/1 kV
Power cables used for lighting and low voltage circuits.
TERAIL - P - M
General Description
Use
Multicore medium voltage cables 3.6/6 kV
Power cables for the supply of signalling and auxiliary circuits.
TERAIL - P - M6 kV
General Description
Use
Single core low voltage cables 0.45/0.75 kV
Power flexible cables for equipment and rail track connections.
TERAIL - P - 0,75 kV
General Description
Use
Fire Resistant Power cables adapted to provide all services listed above
Fire hazard safety systems for general indoor use.
TERAIL - P - FR
General Description
Use
Screened (T) multipair and multiquads cables Armoured
Cabling of line and local Telecommunication systems.
TERAIL - C - TSA
General Description
Use
Screened (T) multipair and multiquad cables
Cabling of local Telecommunication systems.
TERAIL - C - TS
General Description
Use
75 Ohm COAXial cable
Video communication systems.
TERAIL - C - COAX
General Description
Use
Single mode and multi mode OPTICal fiber cables
High bit-rate data transmission with dangerous EMC conditions and long distance connections.
TERAIL - C - OPTIC
General Description
Use
Fire Resistant communication cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - C - FR
General Description
Use
POWER CABLES
Prysmian Cables & Systems is a world-classmultinational company. Founded in 1872 as “DittaPirelli & C.”, it has achieved a leading position formore than a century of operations in its two keyinternational markets - ”Energy Cables & Systems”and ”Telecom Cables & Systems”.
Prysmian Cables and Systems is the world’s largestmanufacturer of power and telecommunicationscables, with 52 manufacturing facilities in 21 countriesin five continents and a market share in excess of 10%.
Prysmian Energy Cables and Systems is a globalsolutions provider, offering a wide range ofintegrated solutions, such as cable systems,system design and engineering, project management,installation and post-sale services.
Prysmian Energy Cables and Systems concentrateson continuous product innovation and on achievinga competitive edge by focusing on research anddevelopment. This is done through Prysmian’s ownR&D centres and by co-operating with universities,scientific institutions and above all, our customers.Prysmian’s world-wide organisation makes anddelivers advanced technological solutions tocustomers anywhere in the world.
Prysmian’s TECHNERGY integrated cabling solutionsTM
is one of the world’s most comprehensiveand technologically advanced answers to industry,infrastructure, contractors and OEM’s specificrequirements.
TECHNERGY integrated cabling solutionsTM are designedand structured into twelve different product lines. Eachof these offer tailored designs and added value solutionsto the most diverse functional and environmentalrequirements in the following fields:
> Trains > Cranes & Mobile Equipments
> Marine > Electro-Mechanical
> Oil & Gas > Data & Communication
> Plant & Petrochem > Transportation Infrastuctures
> Mining & Tunnelling > Building & Civil Engineering
> Defence > Power Plants
To find out more about the TECHNERGY integratedcabling solutionsTM, Prysmian Cables and Systemsinvites you to visit the web site: www.prysmian.com
About us Cable families at a glance
RAILWAY & UNDERGROUND TRAVELLING IN COMPLETE SAFETY
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Prysmian has a built in, multi-step quality assuranceprogram, covering the production process from cabledesign and raw material purchasing to final inspectionand testing documentation.
The quality control system of Prysmian has beenassessed and approved and is audited regularly byLloyd's Register of Quality Assurance to the ISO9001 and ISO 14001 Quality System Standards.
The ISO 14001 is the environment quality standard.
Prysmian's TechnergyTM cable factories have approvalsfor their cables at:
> APPROVALSATM - Ferrovie dello StatoMetropolitana MilaneseRail Track - RATP - SNCF
Prysmian works closely with major classification societies.
Qualitycommitment
Accessoriesand modular systems
Referencesproject
Today's industrial world recognises the importance of“system solutions” in many areas. A system gives morethan raw materials alone: it gives benefits and addedvalue that mean competitive advantage. Traditionalinstallation methods for tunnels, bridges and streetlighting involve a considerable amount of on-siteconnection work through the preparation of terminationboxes or cable joints.
LIGHTING MODULAR SYSTEMFlexoTM modular power cable systems have integralsocket outlets, which are factory produced throughoutthe length of the main supply cable. This allows simpleplug-in connections that remove the need for junctionboxes and time-consuming on-site glanding andtermination. The plug leads can be connected to thelights prior to their being secured. The main cablesystem, with integrated sockets, supplied on standarddrums can then be installed as simply as a cable. Wheninstalled, the sockets align with the light fittings andconnections are made by a simple plug-in action.
BENEFITS> Cost
Installation cost savings of up 30%> Speed
Typically 250m can be installed in only 90 minutes> Skill
Reduced skill requirement for plug-in connections> Flexibility
Selectable phase loading easily achieved> Accuracy
Right first time, every time, guaranteed> Reliability
Factory produced and tested to ensure highestquality connections
> SimplicityMaintenance free, simple light fitting replacement
Project Customer CountryAlta Velocità,(Tratta Roma-Napoli) Ansaldo, Alstom ItalyCTRL(High Speed London-Channel) CSEE U.K.Eurotunnel Eurotunnel France, U.K.LUL Central Line Westinghouse U.K.LUL Northern Line LUL U.K.Metro Milano ATM ItalyMetro Napoli Ansaldo, Italtel ItalyMTR North-East Line Singapore Technology SingaporeMTRC Hong Kong Matra Transport Hong KongOslo Metro Westinghouse NorwayRailways Mexico Matra International MexicoTram Lisbonne CSEE Portugal
EVEREXHigh Performance Compound
SAFETY LINETM
Single core medium voltage cables 1.8 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - 1,8 kV
TERAIL
POWER COMMUNICATION Multicore cables
General signalling system, detection and survey.
TERAIL - S - M
General Description
Use
Multicore cables Armoured
General signalling system, detection and survey when mechanical protection is required.
TERAIL - S - MA
General Description
Use
Unscreened (T) multipair cables Armoured
General signalling system when mechanical protection is required.
TERAIL - S - TA
General Description
Use
Screened (T) mutlipair and multiquad cables with (X) anti-inductive Armour
Signalling system in lines with 25 kV rated voltage and "high speed lines".
TERAIL - S - TSAX
General Description
Use
Flexible Multicore cables
Cabling of indoor equipment of signalling circuits.
TERAIL - S - FM
General Description
Use
Screened Flexible Multicore cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FMS
General Description
Use
Flexible (T) multipair cables
Cabling of signalling circuits, indoor equipment.
TERAIL - S - FT
General Description
Use
Screened Flexible (T) multipair cables
Cabling of signalling circuits indoor equipment with EMC requirements.
TERAIL - S - FTS
General Description
Use
Fire Resistant signalling cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - S - FR
General Description
Use
SIGNALLING TERAIL
SIGNALLING CABLES TERAIL
COMMUNICATION CABLES
General Description
Use
Multicore medium voltage cables 1.8/3 kV
Power cabling with special fire performance, used for track feeder circuits.
TERAIL - P - M3 kV
General Description
Use
Single core medium voltage cables 25 kV
Power cabling with special fire performance used for track side aerial lines.
TERAIL - P - 25 kV
General Description
Use
Multicore low voltage cables 0.6/1 kV
Power cables used for lighting and low voltage circuits.
TERAIL - P - M
General Description
Use
Multicore medium voltage cables 3.6/6 kV
Power cables for the supply of signalling and auxiliary circuits.
TERAIL - P - M6 kV
General Description
Use
Single core low voltage cables 0.45/0.75 kV
Power flexible cables for equipment and rail track connections.
TERAIL - P - 0,75 kV
General Description
Use
Fire Resistant Power cables adapted to provide all services listed above
Fire hazard safety systems for general indoor use.
TERAIL - P - FR
General Description
Use
Screened (T) multipair and multiquads cables Armoured
Cabling of line and local Telecommunication systems.
TERAIL - C - TSA
General Description
Use
Screened (T) multipair and multiquad cables
Cabling of local Telecommunication systems.
TERAIL - C - TS
General Description
Use
75 Ohm COAXial cable
Video communication systems.
TERAIL - C - COAX
General Description
Use
Single mode and multi mode OPTICal fiber cables
High bit-rate data transmission with dangerous EMC conditions and long distance connections.
TERAIL - C - OPTIC
General Description
Use
Fire Resistant communication cables with all options listed above
Fire hazard safety systems for general indoor use.
TERAIL - C - FR
General Description
Use
POWER CABLES
Prysmian Cables & Systems is a world-classmultinational company. Founded in 1872 as “DittaPirelli & C.”, it has achieved a leading position formore than a century of operations in its two keyinternational markets - ”Energy Cables & Systems”and ”Telecom Cables & Systems”.
Prysmian Cables and Systems is the world’s largestmanufacturer of power and telecommunicationscables, with 52 manufacturing facilities in 21 countriesin five continents and a market share in excess of 10%.
Prysmian Energy Cables and Systems is a globalsolutions provider, offering a wide range ofintegrated solutions, such as cable systems,system design and engineering, project management,installation and post-sale services.
Prysmian Energy Cables and Systems concentrateson continuous product innovation and on achievinga competitive edge by focusing on research anddevelopment. This is done through Prysmian’s ownR&D centres and by co-operating with universities,scientific institutions and above all, our customers.Prysmian’s world-wide organisation makes anddelivers advanced technological solutions tocustomers anywhere in the world.
Prysmian’s TECHNERGY integrated cabling solutionsTM
is one of the world’s most comprehensiveand technologically advanced answers to industry,infrastructure, contractors and OEM’s specificrequirements.
TECHNERGY integrated cabling solutionsTM are designedand structured into twelve different product lines. Eachof these offer tailored designs and added value solutionsto the most diverse functional and environmentalrequirements in the following fields:
> Trains > Cranes & Mobile Equipments
> Marine > Electro-Mechanical
> Oil & Gas > Data & Communication
> Plant & Petrochem > Transportation Infrastuctures
> Mining & Tunnelling > Building & Civil Engineering
> Defence > Power Plants
To find out more about the TECHNERGY integratedcabling solutionsTM, Prysmian Cables and Systemsinvites you to visit the web site: www.prysmian.com
About us Cable families at a glance
RAILWAY & UNDERGROUND TRAVELLING IN COMPLETE SAFETY
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Prysmian has a built in, multi-step quality assuranceprogram, covering the production process from cabledesign and raw material purchasing to final inspectionand testing documentation.
The quality control system of Prysmian has beenassessed and approved and is audited regularly byLloyd's Register of Quality Assurance to the ISO9001 and ISO 14001 Quality System Standards.
The ISO 14001 is the environment quality standard.
Prysmian's TechnergyTM cable factories have approvalsfor their cables at:
> APPROVALSATM - Ferrovie dello StatoMetropolitana MilaneseRail Track - RATP - SNCF
Prysmian works closely with major classification societies.
Qualitycommitment
Accessoriesand modular systems
Referencesproject
Today's industrial world recognises the importance of“system solutions” in many areas. A system gives morethan raw materials alone: it gives benefits and addedvalue that mean competitive advantage. Traditionalinstallation methods for tunnels, bridges and streetlighting involve a considerable amount of on-siteconnection work through the preparation of terminationboxes or cable joints.
LIGHTING MODULAR SYSTEMFlexoTM modular power cable systems have integralsocket outlets, which are factory produced throughoutthe length of the main supply cable. This allows simpleplug-in connections that remove the need for junctionboxes and time-consuming on-site glanding andtermination. The plug leads can be connected to thelights prior to their being secured. The main cablesystem, with integrated sockets, supplied on standarddrums can then be installed as simply as a cable. Wheninstalled, the sockets align with the light fittings andconnections are made by a simple plug-in action.
BENEFITS> Cost
Installation cost savings of up 30%> Speed
Typically 250m can be installed in only 90 minutes> Skill
Reduced skill requirement for plug-in connections> Flexibility
Selectable phase loading easily achieved> Accuracy
Right first time, every time, guaranteed> Reliability
Factory produced and tested to ensure highestquality connections
> SimplicityMaintenance free, simple light fitting replacement
Project Customer CountryAlta Velocità,(Tratta Roma-Napoli) Ansaldo, Alstom ItalyCTRL(High Speed London-Channel) CSEE U.K.Eurotunnel Eurotunnel France, U.K.LUL Central Line Westinghouse U.K.LUL Northern Line LUL U.K.Metro Milano ATM ItalyMetro Napoli Ansaldo, Italtel ItalyMTR North-East Line Singapore Technology SingaporeMTRC Hong Kong Matra Transport Hong KongOslo Metro Westinghouse NorwayRailways Mexico Matra International MexicoTram Lisbonne CSEE Portugal
EVEREXHigh Performance Compound
SAFETY LINETM
SUBURBAN
SUBSTATION
UNDERGROUND
HIGH SPEED
STATION
URBAN
INTERURBAN
• TechnergyTMRailway & Undergroundcables include a full range ofFire Resistant cables specificallydeveloped for underground linesand tunnels. For human andequipment safety purposes, inthese types of installations,emergency exits and vital lifeguardservices must operate properlyeven under fire conditions, for aminimum time necessary to letpeople out and to permit theintervention of firefighters. Forthese applications, Prysmianoffers a complete range of cables,which exceed the most severefire resistance standards, evenfor communication purposes.
• Prysmian has always been atthe forefront of meeting therequirements of the mostadvanced railway standardswithin the ERTMS (EuropeanRail Traffic Management System)and according to the requirementsof European transportationcompanies, railway designersand installers. New standardsare aimed at creating a singlerailway signalling and controlsystem, which guarantees interoperability throughout theEuropean Rail Network. TheERTMS require high levels ofEMC performance.
TechnergyTMRailway & Undergroundcables are designed and built tocomply with such demanding EMCrequirements and use specialmaterials and screening designs.
• Prysmian has an internationalnetwork of technically skilledsales offices coordinated by theheadquarters, which ensuresthat our customers have a localand easy-to-reach sales andtechnical contact point.
• Full project documentation andtechnical consulting is suppliedto all of our customers as partof our sales support program.
• TechnergyTMRailway & Undergroundcables are available on shortlead times or from stock.
> Fire Resistant Cables
> ERTMS Compliance > Contract Managementand Stock Availability
TRAVELLING IN COMPLETE SAFETY
Furthermore, new cable designs and materials have been developed in order to meet the most demandingrequirements of the Railway and Underground industry.TechnergyTM provides a full range of products that incorporate these railway technologies, including Medium andLow Voltage Power cables, Communication cables, and Control and Signalling cables.
TechnergyTM Railway & Underground cables offer Rail and MTR authorities and operators, contractors,specifiers, system designers and installers the following benefits:
EVEREXHigh Performance Compound INIATURISEDM
SAFETY LINETM
fumex® Application
Benefits
The rapid development of railway technologies in recent years has impacted all areas, from mass transit tohigh-speed lines. The railway systems themselves, from DC to 2x25 kV AC, have undergone a similar evolution.System complexity and reliability, as well as safety, are the key results of this remarkable change.A key effect of these advances is the development of cables with high levels of performance in terms of chemicaland mechanical resistance, fire resistance, EMC behaviour and transmission capacity.
• Durability: TechnergyTM Railway& Underground cables have aproven track record in extendedworking lifetime versus standardrailway cables and need minimummaintenance.
• E0 and easy-stripping compoundsmake installation easier, fasterand - as a result - less expensive.
• Components: Prysmian suppliessets of assembly components, tailor-made to your needs thatsignificantly reduce installationtime.
• Completeness: a comprehensiveproduct range, covering all functionalities (MV/LV, Controland Signalling, Video and DataTransmission, Optical Fibers).
• Railway’s Cable Outfit: TechnergyTM
Railway & Underground cablesare suitable for any power andcommunication system, as wellas signalling andcontrol devices.Prysmian provides cables, such asBOA, EUROBALISE, ENCODER-BOA,ZCO3, for the most demandingand advanced applications.
• Customised Cable Design: Prysmiancan provide cables and compoundstailor-made to specific applications,according to specified customerrequirements (e.g. for extraordinarilyheavy duty and harsh environments).
• Prysmian has always focused itsattention on both human andmaterial safety in all workingconditions. In railway applications,cables are often installed in verycritical conditions such as tunnelsand deep underground lines. Inthis case, it is very important touse cables that under fireconditions, do not increase firerelated hazards and that ensure theproper running of safety devicesunder extreme circumstances.
Under fire conditions the typicallyrequired light transmittance forLSOH cables’ smoke emissionsis not lower than 60%.TechnergyTM
Railway & Underground cablescomply with the highest standards,which establish that smokeemissions must have a lighttransmittance higher than 75%.
RAILWAY & UNDERGROUND
> Lower Total Costof Ownership
> Unique Safetyin Fire Hazard
> OutstandingProduct
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
technergytechnergyINTEGRATED CABLING SOLUTIONS
TM
Railway &Underground
Cablesd
ega
des
ign
grou
pWorld Wide Excellence Centertel. +33 3 8695 7769, fax +33 3 8695 7781
Head OfficePrysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com
ARGENTINAPrysmian Energía Cables y Sistemasde Argentina S. A.Fábrica La Rosa, Av. da Argentina 67841439 Capital Federaltel. +54 11 46302000fax +54 11 46302100
AUSTRALIAPrysmian Power Cables & SystemsAustralia PTY LTD1 Heathcote RoadLocked Bag 7042, Liverpool Business Centre 1871NSWtel. +61 2 96000 777fax +61 2 96000 747
AUSTRIAPrysmian OEKW GmbHLembockgasse 47A, 1230 Wientel. +43 1 866770fax +43 1 86677109
BRAZILPrysmian Energia Cabos e Sistemas do Brasil S. A.Av. Alexandre de Gusmao 14509110-900 Santo André - SPtel. +55 11 49984000fax +55 11 49984811
CHINAPrysmian Tianjin Cables Co. Ltd.513, Huang He Road, Nankai DistrictTianjin, 300112tel. +86 22 2753 9679fax +86 22 2753 3485
EGYPTPrysmian Cables & Systems8 Abd El Azim Aoudallah st. Hegaz sq.Heliopolis - Cairotel. +20 2 2418557fax +20 2 6381327
FINLANDPrysmian Cables & Systems OyP.O. Box 13FIN-02401 Kirkkonummitel. +358 10 77551fax +358 9 2982204
FRANCEPrysmian Energie Cables et Systèmes France s.a.19, Avenue de la Paix - BP 712Paron - 89100, Sens Cedextel. +33 3 86957769fax +33 3 86957781
GERMANYPrysmian Kabel und Systeme GmbHAustrasse 9996465 Neustadt bei Coburgtel. +49 9568 93 2697fax +49 9568 93 2527
HONG KONGPrysmian Cable Systems Pte. Ltd.Unit A, 18/F, China Overseas Building139 Hennessy RoadWanchai, Hong Kongtel. +85 2 2827 8308fax +85 2 2827 7212
HUNGARYPrysmian MKM Magyar Hungarian CableWorks Co. Ltd.Baràzda u. 38H-1116 Budapesttel. +36 1 3822222fax +36 1 3822202
INDONESIAPT. Prysmian Cables IndonesiaGedung BRI II, Suite 1502Jln. Jend Sudirman No 44-46Jakarta 10210tel. +62 264 351222fax +62 264 351780
ITALYPrysmian Cavi e Sistemi Energia Italia SrlViale Sarca 222, 20126 Milanotel. +39 02 6449 69753fax +39 02 6449 5096
MALAYSIAPrysmian Cable Systems Pte. Ltd.Lot 2 Jalan Kawat 15/18, 40702 Shah AlamSelangor Darul Ehsantel. +60 3 5518 4575fax +60 3 5511 9590
NETHERLANDSPrysmian Cables and Systems B.V.Schieweg 9, 2627 AN Delft P.O. Box 495, 2600 AL DelftThe Netherlandstel. +31 15 260 5260 fax +31 15 261 3808
NEW ZEALANDPrysmian Cables & Systems71 Hugi Johnson Drice, P.O. Box 12162Penrose, Aucklandtel. +64 9 5251260fax +64 9 5251262
NORTH AMERICAPrysmian Cables & Systems North America700 Industrial DriveLexington, SC 29072 - USAtel. +1 803 9511130fax +1 803 9511092
NORWAYPrysmian Kabler og Systmer ASP.O.Box 1384, N - 1401 Skitel. +47 64 915713fax +47 64 915714
ROMANIAPrysmian Cabluri si Sisteme SASoseaua Draganesti, Km. 40500 Slatinatel. +40 49 435699fax +40 49 433484
RUSSIAPrysmian Cables and Systems20/12, Str.1, Podsosenskiy Per.Moscow 105062, Russiatel. +7 095 933 7036fax +7 095 933 7035
SINGAPOREPrysmian Cable Systems Pte. Ltd.No 4 Tuas Avenue 12. 3rd Storey639047 Singaporetel. +65 6862 9866fax +65 6862 9877
SLOVAKIAPrysmian Kablo s.r.oTovarenska 11812 61 Bratislavatel. +421 7 50211111fax +421 7 52961773
SPAINPrysmian Cables y Sistemas S.L.Carretera C-15, Km. 208800 Vilanova i la Geltrú (Barcelona) tel. +34 93 811 6181fax +34 93 811 6011
SWEDENPrysmian Kablar och System AbGustavslundsvägen 141P.O.Box 14147SE-16714 Brommatel. +46 8 260416fax +46 8 260413
TURKEYTurk Prysmian Kablo ve Sistemleri A.S.Buyukdere Caddesi No 11734394 Gayrettepe, Istanbultel. +90 212 3551500fax +90 212 2175810
U.A.E. (Dubai)Prysmian Cabels and Systems Middle EastP.O. Box 72125, Dubai tel. +971 4 345 7870fax +971 4 345 7101
UKPrysmian Cables & Systems LimitedP. O. Box 6Leigh RoadEastleighHampshire, SO50 9YEtel. +44 2380 295555fax +44 2380 295111
Recommended