View
217
Download
3
Category
Preview:
Citation preview
Industrial Electric Tankless Water HeatersPhD TECHNOLOGY
#1 US BRAND OF TANKLESS WATER HEATING SOLUTIONS
PROVEN PERFORMANCE WITH
PARABOLIC HEAT DESIGN
Faster speed to temperature, moreprecise temperature control, and
less wasted energy.
For Safety Applications
For Commercial & Industrial Applications
WHY EEMAX WITH PhD TANKLESS?• Use as primary heat source rather than
heater• Use as in-line booster to supplement central
boiler or hot water systems• Eliminates need for large storage tanks,
recirculation loops and mixing valves• Simple installation compared to gas fired or
steam systems• Maintenance free operation • Vent and T&P valve NOT REQUIRED• Compact Design
Wall or drop ceiling mountable• Eliminates scalding hazards associated with
traditional boiler loop mixing• No need for hot water purging due to
overshoot• BMS Connectivity• Accurate temperature output (+/- 1°F)
regardless of incoming water temperature• 99% Energy Efficient
APPLICATIONS:• 40 GPM Domestic Hot Water• Eye/Face Wash & Emergency Drench
Showers• Process Water• Batch Heating• In-line Boosting for Precise Temperature
Control• Hydronic Heating• Geothermal Backup• Commercial Kitchen• 180°F Sanitizing Washdown
N LEAD*The wetted surface of this product contacted by water contains less than 0.25% lead and meets California and Vermont Lead Free laws.
Eemax, Inc., 400 Captain Neville Drive, Waterbury, CT 06705
(800) 543-6163 Toll Free
info@eemaxinc.com | www.eemax.com © 2016 Eemax, Inc. All Rights Reserved. EX09001-57 REV 12/2016
Industrial Electric Tankless Water HeatersPhD TECHNOLOGY
Eemax, Inc., 400 Captain Neville Drive, Waterbury, CT 06705
(800) 543-6163 Toll Free
info@eemaxinc.com | www.eemax.com © 2016 Eemax, Inc. All Rights Reserved. EX09001-57 REV 12/2016
OPTIONAL FEATURES• NEMA 4 (powder coated steel) enclosure• NEMA 4X (304, 316 stainless) enclosure• Explosion Proof Class 1/Division 2• Freeze protection down to -30°F• Electrical disconnect (fused or non-fused)• Ground Fault Circuit Interrupter (GFCI)• Siren and/or beacon• Data logging• SafeAdvantage model: Factory limit 90°F
output for ANSI Z358.1 tepid water• Remote mount control box• Leak Detection• Multiple unit configuration (series or
parallel)• Others by customer request
PRODUCT SPECIFICATIONS• Rated Pressure, 150 PSI• Temp Output, 80° - 180°F (model specific)• Temp Accuracy, +/- 1°F at steady state• Max Flow Rate of 40 GPM• Turn On as low as 1 GPM (model specific)• 600v, 480v and 208v 3 Phase Δ (3 live, 1
ground)• UL Listed: UL 499 and NSF/ANSI 372• ETL Listed: CSA 22.2 No 88
AP144480, AP061600, AP071600, AP102600, AP130600, AP150600; may be followed by S, EFD, N4, N4X, 6
• US Patent Pending
UNIT
SIZ
ES
36 - 48 kW 480V (123,000-164,000 Btu/h)
17.2”H x 17.7”W x 10.5”D 42lbs
32 - 64 kW 208V (109,000-218,000 Btu/h)
54 - 144 kW 480V (184,000-491,000 Btu/h)
61 - 150 kW 600V (208,000-512,000 Btu/h)
17.4”H x 26.2”W x 10.3”D 68 lbs
Recommended