12
Portfolio Huawei WDM Enterprise Network

波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Embed Size (px)

Citation preview

Page 1: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Portfolio

Huawei WDM

Enterprise Network

Page 2: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

OSN902

01

Dimensions (H x W x D) (mm)

Cabinet

Number of Slots for ServiceBoardsService Type

Supported Pluggable Optical Modules

Line Rate

Network-level Protection

Management Interfaces

Nominal Working Voltage

Heat Dissipation

Power Consumption

Operating Environment(Temperature)

Operating Environment(Relative Humidity)

86.1 x 442 x 600

5% to 95%

0°C (32°F) to 40°C (104°F)

1200W (max.)

Front air inlet and rear air outlet

90V to 264V AC, 50/60 Hz192V to 288V HVDC

CLI/SNMP/U2000

Client 1+1 protection, intra-board 1+1 protection,and optical line protection

1 + 1 power supply backup, 2 +1 backup for the fan tray assembly

100G (PDM-QPSK) programmable200G (PDM-16QAM) programmable

QSFP+, QSFP28

10GE, 40GE, and 100GE

6

19-inch cabinet

Equipment-level Protection

Page 3: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Dimensions (H x W x D) (mm)

Cabinet

Service Type

Transport Capacity

Protection

Nominal Working Voltage

Heat Dissipation

Power Consumption

Weight

Operation Environment(Temperature)Operation Environment(Relative Humidity)

43.6 x 220 x 200

Installed in a 19-inch cabinet,placed on a desk, or mounted on the wall.

GE, 10GE LAN

10G

LPT

100V to 240V AC, 50/60 Hz

Natural heat dissipation

1.6 kg (3.53lb)

0°C (32 °F) to 45°C (113 °F)

17W (max.)

5% to 95%

Dimensions (H x W x D) (mm)

Cabinet

Service Type

Transport Capacity

Protection

Nominal Working Voltage

Power Consumption

Weight

Protection Rating

420 x 300 x 90

Supports pole-mounted installation, wall-mounted installation, and installation with Huawei Blade RRU.

GE, 10GE LAN, CPRI 2/3/4/5/6/7/8, OBSAI 4x/8x, and STM-1/4/16

50G/100G

LPT

-57V to -36V DC85V to 290V AC

≤ 12 kg (26.46 lb)

Solar radiation (≤ 1120 W/m2) running: -40°C (-40°F) to 50°C (122°F)No solar radiation running: -40°C (-40°F) to 55°C (131°F)

100W (max.)/50G130W (max.)/100G

IP65

01 OSN 81003

OSN 85002

Operation Environment(Temperature)

Page 4: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

DC-powered chassis: 3AC-powered chassis: 1

DC-powered chassis: 7AC-powered chassis: 5

DC-powered chassis: 15AC-powered chassis: 12

88 x 442 x 220

N63E, N63B,19-inch cabinet, 19-inch open rack,and F01S300 cabinet (only when working with F3SCC)

221 x 442 x 224 44 x 442 x 220

1-degree to 4-degree ROADM

N63E, N63B,19-inch cabinet,Minishelter outdoorcabinet

1-degree to 9-degree ROADM

OTN: 700G ODUk(k=0, 1, 2, 2e, 3, 4, or �ex)Packet: 700G TDM: 280G VC-4 40G VC-3/VC-12

Supports inter-board cross-connections of any services at a rate lower than 1.25 Gbit/s and 10GE LAN services.Supports intra-board cross-connections of any services at a rate lower than 2.5 Gbit/s; intra-board cross-connection of VC-4 or VC-12; and ODUk (k=0, 1, 2, or �ex) services.

Dimensions (H x W x D) (mm)

Cabinet

Number of Slotsfor Service Boards

Optical Switching Capability

Electrical SwitchingCapability

1800 I Compact 1800 II Compact

04 1800 V

DWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1), 80 wavelengthsCWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2), 8 wavelengths

Wavelength Range and Max. Number of Wavelengths

OSN 1800

Page 5: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

1800 V1800 I/II Compact

2.5G/10G/100G

Operation Environment(Temperature)

Operation Environment(Relative Humidity)

Network-level Protection (OTN)

Network-level Protection (Packet)

Network-level Protection (OCS)

Synchronization

TSDN

Nominal Working Voltage

Service Type

Line Rate

Equipment-level Protection

SFP, SFP+, XFP, TXFP, CFP, CFP2, and QSFP+

Control, cross-connect, and clock integrated board redundancy, power supply redundancy, and fan redundancy

Supported PluggableOptical Modules

SDH, PDH, OTN, Ethernet, CPRI, OBSAI, SAN, video

Optical line protection,intra-board 1+1 protection,client 1+1 protection, ODUk SNCP, tributary SNCP, and LPT

SDH protection: SNCP, linear MSP, and ring MSPEoS protection: LAG, DLAG, LCAS, LPT,and STP/RSTP

Tunnel APS, PW APS/FPS,MC-LAG, ERPS, LAG, packet SNCP, MRPS, and LPT

Supported

-48V/-60V DC110V/220V ACLong-term operation:-5°C (23 °F) to 50°C (122 °F)Short-term operation: -10°C (14 °F) to 55°C (131 °F)

Power supply redundancy ,fan redundancy

SDH, PDH, OTN, Ethernet, CPRI, OBSAI, SAN, video, SONET

Optical line protection,intra-board 1+1 protection,client 1+1 protection, ODUk SNCP, and LPT

Not supported

-48V/-60V DC110V/220V ACLong-term operation: -5°C (23 °F) to 55°C (131 °F)Short-term operation: -10°C (14 °F) to 55°C (131 °F)

Long-term operation: 5% to 85%Short-term operation: 5% to 95%

OTN: physical clock, IEEE 1588v2, ITU-T G.8275.1/G.8273.2TDM: SDH synchronization clock, synchronous Ethernet clock

Packet: physical clock, IEEE 1588v2–

Page 6: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

900 x 498 x 580

N66B

64

900 x 498 x 295

N63B, N66B

32

1-degree to 20-degree ROADM

ODUk (k=0, 1, 2, 2e, 3, 4, or �ex)

OTN: 6.4T ODUkTDM:1.28T VC-4 80G VC-3/VC-12

OTN: 3.2T ODUk Packet: 1.6TTDM: 1.28T VC-4 80G VC-3/VC-12

N63B, N66B

450 x 498 x 295

16

OTN: 1.6T ODUk Packet: 800GTDM: 640G VC-4 20G VC-3/VC-12

DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1),Fixed grid: 80/96 wavelengthsFlexiable grid: con�gurableCWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2),8 wavelengths

SDH, SONET, Ethernet, SAN, OTN, and video

2.5G/10G/40G/100G/200G

Dimensions (H x W x D) (mm)Cabinet

Number of Slotsfor Service Boards

Optical SwitchingCapability

Electrical SwitchingCapability

Wavelength Range and Max. Number of Wavelengths

Service Type

Line Rate

OSN 8800 T16 OSN 8800 T32 OSN 8800 T64

05

Page 7: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Supported Pluggable Optical Modules

eSFP, SFP+, XFP, CFP, and QSFP28

Supported

Supports application of extended C band in submarine scenarios

-48V/-60V DC

Power supply redundancy , fan redundancy, cross-connect board redundancy, system control and communication board redundancy,centralized clock board redundancy, and AUX board 1+1 redundancy

Optical line protection, intra-board 1+1 protectionclient 1+1 protection, ODUk SNCP, tributary SNCP, and ODUk SPRing protection

DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP/RSTP, Tunnel APS, and VLAN SNCP

Long-term operation: 5°C (41 °F) to 45°C (113 °F)Short-term operation: -5°C(23 °F) to 55°C (131 °F)

Long-term operation: 5% to 85%Short-term operation: 5% to 95%

LMSP, MSP ring, Transoceanic MSP ring, SNCP, and SNCTP

OTN: physical clock, IEEE 1588v2, and ITU-T G.8275.1/G.8273.2Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock

OTN network: Optical-layer ASON, Electrical-layer ASONOCS network: SDH ASON

OSN 8800 T16 OSN 8800 T32 OSN 8800 T64

ASON

OperatingEnvironment(Temperature)

OperatingEnvironment(Relative Humidity)

Equipment-levelProtection

Network-level Protection (OTN)

Network-level Protection (Packet)

Network-levelProtection (OCS)

Synchronization

Submarine Features

TSDN

Nominal Working Voltage

Page 8: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

2200 x 600 x 600

The subrack is integrated into a cabinet

64

1900 x 498 x 295

N63B, N66B

ODUk (k=0, 1, 2, 2e, 3, 4, or �ex)

32

OTN: 25.6T ODUkPacket: 12.8TTDM: 5.12T VC-4 80G VC-3/VC-12

OTN: 12.8T ODUkPacket: 6.4TTDM: 2.56T VC-4 80G VC-3/VC-12

847 x 442 x 295

N63B, N66B19-Inch Cabinet

14

OTN: 5.6T ODUkPacket: 2.8TTDM: 1.12T VC-4 80G VC-3/VC-12

DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)Fixed grid: 80/96 wavelengthsFlexiable grid: con�gurable

SDH, SONET, Ethernet, SAN, OTN, and video

10G/40G/100G/200G/400G

Dimensions (H x W x D) (mm)

Cabinet

Number of Slotsfor Service Boards

Electrical SwitchingCapability

Wavelength Range and Max.Number of Wavelengths

Service Type

Line Rate

OSN 9800 U16 OSN 9800 U32 OSN 9800 U64

06

Page 9: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Supported Pluggable Optical Modules

eSFP, SFP+, XFP, CFP, CXP, and CFP2

Supported

Supports application of extended C band in submarine scenarios.

-48V/-60V DC

Power supply redundancy , fan redundancy, cross-connect board redundancy, communication control and clock processing unit redundancy

Client 1+1 protection, intra-board 1+1 protection, LPT,ODUk SNCP, tributary SNCP, and Port-level M: N protection

ERPS, LAG, LPT, MC-LAG, LMSP, MC-LMSP, MRPS, PW APS, MC-PW APS, and tunnel APS

Long-term operation: 5% to 85%Short-term operation: 5% to 90%

LMSP, SNCP

OTN: Physical clock, IEEE 1588v2, and ITU-T G.8275.1Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock

Electrical-layer ASON

OSN 9800 U16 OSN 9800 U32/U64

ASON

Operation Environment(Temperature)

Operation Environment(Relative Humidity)

Equipment-level Protection

Network-levelProtection (OTN)

Network-level Protection (Packet)

Network-levelProtection (OCS)

Synchronization

Submarine Features

TSDN

Nominal WorkingVoltage

Long-term operation: 5°C (41 °F) to 40°C (104 °F)Short-term operation: -5°C (23 °F) to 50°C (122 °F)

Long-term operation: 5°C (41 °F) to 40°C (104 °F)Short-term operation: -5°C (23 °F) to 45°C (113 °F)

Page 10: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

397 x 442 x 295

N63B, N66B, 19-Inch Cabinet

16

1-degree to 20-degree ROADM

DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)Fixed grid: 80/96 wavelengthsFlexiable grid: con�gurable

SDH, SONET, Ethernet, SAN, OTN, and video

2.5G/10G/40G/100G/200G

07

Power supply redundancy , fan redundancysystem control and communication board redundancy

OSN 8800 UPS OSN 9800 UPS

eSFP, SFP+, XFP, CFP, and QSFP28

Dimensions(H x W x D) (mm)

Cabinet

Number of Slots forService Boards

Optical SwitchingCapability

Wavelength Rangeand Max. Numberof Wavelengths

Service Type

Line Rate

Equipment-level Protection

Supported Pluggable Optical Modules

Page 11: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Supported

Supports application of extended C band in submarine scenarios

-48V/-60V DC110V/120V AC

Long-term operation: 5°C (41 °F) to 45°C (113 °F)Short-term operation: -5°C (23 °F) to 55°C (131 °F)

Optical-layer ASONASON

Operation Environment(Temperature)

Operation Environment(Relative Humidity)

Network-level Protection (OTN)

Synchronization

Submarine Features

TSDN

Nominal Working Voltage

OSN 8800 UPS OSN 9800 UPS

OTN: physical clock, IEEE 1588v2, and ITU-T G.8275.1Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock

Optical line protection,intra-board 1+1 protection,client 1+1 protection,and LPT

Long-term operation: 5% to 85%Short-term operation: 5% to 95%

OTN: physical clock, IEEE 1588v2, and ITU-TG.8275.1/G.8273.2Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock

Long-term operation: 5% to 85%Short-term operation: 5% to 90%

Page 12: 波分全家福 en 阅读版 - g11n.ltd Convergence... · OSN 1800. 1800 I/II Compact 1800 V 2.5G/10G/100G Operation Environment (Temperature) Operation Environment (Relative Humidity)

Copyright © Huawei Technologies Co.,Ltd. 2017. ALL rights reserved.

[email protected]

http://e.huawei.com/go/trans-en

Experience more documents