Enterprise Network
OSN902
01
Dimensions (H x W x D) (mm)
Cabinet
Number of Slots for ServiceBoardsService Type
Supported Pluggable Optical Modules
Line Rate
Network-level Protection
Management Interfaces
Nominal Working Voltage
Heat Dissipation
Power Consumption
Operating Environment(Temperature)
Operating Environment(Relative Humidity)
86.1 x 442 x 600
5% to 95%
0°C (32°F) to 40°C (104°F)
1200W (max.)
Front air inlet and rear air outlet
90V to 264V AC, 50/60 Hz192V to 288V HVDC
CLI/SNMP/U2000
Client 1+1 protection, intra-board 1+1 protection,and optical line protection
1 + 1 power supply backup, 2 +1 backup for the fan tray assembly
100G (PDM-QPSK) programmable200G (PDM-16QAM) programmable
QSFP+, QSFP28
10GE, 40GE, and 100GE
6
19-inch cabinet
Equipment-level Protection
Dimensions (H x W x D) (mm)
Cabinet
Service Type
Transport Capacity
Protection
Nominal Working Voltage
Heat Dissipation
Power Consumption
Weight
Operation Environment(Temperature)Operation Environment(Relative Humidity)
43.6 x 220 x 200
Installed in a 19-inch cabinet,placed on a desk, or mounted on the wall.
GE, 10GE LAN
10G
LPT
100V to 240V AC, 50/60 Hz
Natural heat dissipation
1.6 kg (3.53lb)
0°C (32 °F) to 45°C (113 °F)
17W (max.)
5% to 95%
Dimensions (H x W x D) (mm)
Cabinet
Service Type
Transport Capacity
Protection
Nominal Working Voltage
Power Consumption
Weight
Protection Rating
420 x 300 x 90
Supports pole-mounted installation, wall-mounted installation, and installation with Huawei Blade RRU.
GE, 10GE LAN, CPRI 2/3/4/5/6/7/8, OBSAI 4x/8x, and STM-1/4/16
50G/100G
LPT
-57V to -36V DC85V to 290V AC
≤ 12 kg (26.46 lb)
Solar radiation (≤ 1120 W/m2) running: -40°C (-40°F) to 50°C (122°F)No solar radiation running: -40°C (-40°F) to 55°C (131°F)
100W (max.)/50G130W (max.)/100G
IP65
01 OSN 81003
OSN 85002
Operation Environment(Temperature)
DC-powered chassis: 3AC-powered chassis: 1
DC-powered chassis: 7AC-powered chassis: 5
DC-powered chassis: 15AC-powered chassis: 12
88 x 442 x 220
N63E, N63B,19-inch cabinet, 19-inch open rack,and F01S300 cabinet (only when working with F3SCC)
221 x 442 x 224 44 x 442 x 220
1-degree to 4-degree ROADM
N63E, N63B,19-inch cabinet,Minishelter outdoorcabinet
1-degree to 9-degree ROADM
OTN: 700G ODUk(k=0, 1, 2, 2e, 3, 4, or �ex)Packet: 700G TDM: 280G VC-4 40G VC-3/VC-12
Supports inter-board cross-connections of any services at a rate lower than 1.25 Gbit/s and 10GE LAN services.Supports intra-board cross-connections of any services at a rate lower than 2.5 Gbit/s; intra-board cross-connection of VC-4 or VC-12; and ODUk (k=0, 1, 2, or �ex) services.
Dimensions (H x W x D) (mm)
Cabinet
Number of Slotsfor Service Boards
Optical Switching Capability
Electrical SwitchingCapability
1800 I Compact 1800 II Compact
04 1800 V
DWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1), 80 wavelengthsCWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2), 8 wavelengths
Wavelength Range and Max. Number of Wavelengths
OSN 1800
1800 V1800 I/II Compact
2.5G/10G/100G
Operation Environment(Temperature)
Operation Environment(Relative Humidity)
Network-level Protection (OTN)
Network-level Protection (Packet)
Network-level Protection (OCS)
Synchronization
TSDN
Nominal Working Voltage
Service Type
Line Rate
Equipment-level Protection
SFP, SFP+, XFP, TXFP, CFP, CFP2, and QSFP+
Control, cross-connect, and clock integrated board redundancy, power supply redundancy, and fan redundancy
Supported PluggableOptical Modules
SDH, PDH, OTN, Ethernet, CPRI, OBSAI, SAN, video
Optical line protection,intra-board 1+1 protection,client 1+1 protection, ODUk SNCP, tributary SNCP, and LPT
SDH protection: SNCP, linear MSP, and ring MSPEoS protection: LAG, DLAG, LCAS, LPT,and STP/RSTP
Tunnel APS, PW APS/FPS,MC-LAG, ERPS, LAG, packet SNCP, MRPS, and LPT
Supported
-48V/-60V DC110V/220V ACLong-term operation:-5°C (23 °F) to 50°C (122 °F)Short-term operation: -10°C (14 °F) to 55°C (131 °F)
–
–
Power supply redundancy ,fan redundancy
SDH, PDH, OTN, Ethernet, CPRI, OBSAI, SAN, video, SONET
Optical line protection,intra-board 1+1 protection,client 1+1 protection, ODUk SNCP, and LPT
Not supported
-48V/-60V DC110V/220V ACLong-term operation: -5°C (23 °F) to 55°C (131 °F)Short-term operation: -10°C (14 °F) to 55°C (131 °F)
Long-term operation: 5% to 85%Short-term operation: 5% to 95%
OTN: physical clock, IEEE 1588v2, ITU-T G.8275.1/G.8273.2TDM: SDH synchronization clock, synchronous Ethernet clock
Packet: physical clock, IEEE 1588v2–
900 x 498 x 580
N66B
64
900 x 498 x 295
N63B, N66B
32
1-degree to 20-degree ROADM
ODUk (k=0, 1, 2, 2e, 3, 4, or �ex)
OTN: 6.4T ODUkTDM:1.28T VC-4 80G VC-3/VC-12
OTN: 3.2T ODUk Packet: 1.6TTDM: 1.28T VC-4 80G VC-3/VC-12
N63B, N66B
450 x 498 x 295
16
OTN: 1.6T ODUk Packet: 800GTDM: 640G VC-4 20G VC-3/VC-12
DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1),Fixed grid: 80/96 wavelengthsFlexiable grid: con�gurableCWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2),8 wavelengths
SDH, SONET, Ethernet, SAN, OTN, and video
2.5G/10G/40G/100G/200G
Dimensions (H x W x D) (mm)Cabinet
Number of Slotsfor Service Boards
Optical SwitchingCapability
Electrical SwitchingCapability
Wavelength Range and Max. Number of Wavelengths
Service Type
Line Rate
OSN 8800 T16 OSN 8800 T32 OSN 8800 T64
05
Supported Pluggable Optical Modules
eSFP, SFP+, XFP, CFP, and QSFP28
Supported
Supports application of extended C band in submarine scenarios
-48V/-60V DC
Power supply redundancy , fan redundancy, cross-connect board redundancy, system control and communication board redundancy,centralized clock board redundancy, and AUX board 1+1 redundancy
Optical line protection, intra-board 1+1 protectionclient 1+1 protection, ODUk SNCP, tributary SNCP, and ODUk SPRing protection
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP/RSTP, Tunnel APS, and VLAN SNCP
Long-term operation: 5°C (41 °F) to 45°C (113 °F)Short-term operation: -5°C(23 °F) to 55°C (131 °F)
Long-term operation: 5% to 85%Short-term operation: 5% to 95%
LMSP, MSP ring, Transoceanic MSP ring, SNCP, and SNCTP
OTN: physical clock, IEEE 1588v2, and ITU-T G.8275.1/G.8273.2Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock
OTN network: Optical-layer ASON, Electrical-layer ASONOCS network: SDH ASON
OSN 8800 T16 OSN 8800 T32 OSN 8800 T64
ASON
OperatingEnvironment(Temperature)
OperatingEnvironment(Relative Humidity)
Equipment-levelProtection
Network-level Protection (OTN)
Network-level Protection (Packet)
Network-levelProtection (OCS)
Synchronization
Submarine Features
TSDN
Nominal Working Voltage
2200 x 600 x 600
The subrack is integrated into a cabinet
64
1900 x 498 x 295
N63B, N66B
ODUk (k=0, 1, 2, 2e, 3, 4, or �ex)
32
OTN: 25.6T ODUkPacket: 12.8TTDM: 5.12T VC-4 80G VC-3/VC-12
OTN: 12.8T ODUkPacket: 6.4TTDM: 2.56T VC-4 80G VC-3/VC-12
847 x 442 x 295
N63B, N66B19-Inch Cabinet
14
OTN: 5.6T ODUkPacket: 2.8TTDM: 1.12T VC-4 80G VC-3/VC-12
DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)Fixed grid: 80/96 wavelengthsFlexiable grid: con�gurable
SDH, SONET, Ethernet, SAN, OTN, and video
10G/40G/100G/200G/400G
Dimensions (H x W x D) (mm)
Cabinet
Number of Slotsfor Service Boards
Electrical SwitchingCapability
Wavelength Range and Max.Number of Wavelengths
Service Type
Line Rate
OSN 9800 U16 OSN 9800 U32 OSN 9800 U64
06
Supported Pluggable Optical Modules
eSFP, SFP+, XFP, CFP, CXP, and CFP2
Supported
Supports application of extended C band in submarine scenarios.
-48V/-60V DC
Power supply redundancy , fan redundancy, cross-connect board redundancy, communication control and clock processing unit redundancy
Client 1+1 protection, intra-board 1+1 protection, LPT,ODUk SNCP, tributary SNCP, and Port-level M: N protection
ERPS, LAG, LPT, MC-LAG, LMSP, MC-LMSP, MRPS, PW APS, MC-PW APS, and tunnel APS
Long-term operation: 5% to 85%Short-term operation: 5% to 90%
LMSP, SNCP
OTN: Physical clock, IEEE 1588v2, and ITU-T G.8275.1Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock
Electrical-layer ASON
OSN 9800 U16 OSN 9800 U32/U64
ASON
Operation Environment(Temperature)
Operation Environment(Relative Humidity)
Equipment-level Protection
Network-levelProtection (OTN)
Network-level Protection (Packet)
Network-levelProtection (OCS)
Synchronization
Submarine Features
TSDN
Nominal WorkingVoltage
Long-term operation: 5°C (41 °F) to 40°C (104 °F)Short-term operation: -5°C (23 °F) to 50°C (122 °F)
Long-term operation: 5°C (41 °F) to 40°C (104 °F)Short-term operation: -5°C (23 °F) to 45°C (113 °F)
397 x 442 x 295
N63B, N66B, 19-Inch Cabinet
16
1-degree to 20-degree ROADM
DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)Fixed grid: 80/96 wavelengthsFlexiable grid: con�gurable
SDH, SONET, Ethernet, SAN, OTN, and video
2.5G/10G/40G/100G/200G
07
Power supply redundancy , fan redundancysystem control and communication board redundancy
OSN 8800 UPS OSN 9800 UPS
eSFP, SFP+, XFP, CFP, and QSFP28
Dimensions(H x W x D) (mm)
Cabinet
Number of Slots forService Boards
Optical SwitchingCapability
Wavelength Rangeand Max. Numberof Wavelengths
Service Type
Line Rate
Equipment-level Protection
Supported Pluggable Optical Modules
Supported
Supports application of extended C band in submarine scenarios
-48V/-60V DC110V/120V AC
Long-term operation: 5°C (41 °F) to 45°C (113 °F)Short-term operation: -5°C (23 °F) to 55°C (131 °F)
Optical-layer ASONASON
Operation Environment(Temperature)
Operation Environment(Relative Humidity)
Network-level Protection (OTN)
Synchronization
Submarine Features
TSDN
Nominal Working Voltage
OSN 8800 UPS OSN 9800 UPS
OTN: physical clock, IEEE 1588v2, and ITU-T G.8275.1Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock
Optical line protection,intra-board 1+1 protection,client 1+1 protection,and LPT
Long-term operation: 5% to 85%Short-term operation: 5% to 95%
OTN: physical clock, IEEE 1588v2, and ITU-TG.8275.1/G.8273.2Packet: physical clock, IEEE 1588v2TDM: SDH synchronization clock, synchronous Ethernet clock
Long-term operation: 5% to 85%Short-term operation: 5% to 90%