1. - Condensate pump and feed pump trip! -Turbine trips! 2

Embed Size (px)

Citation preview

Page 1: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

1

Page 2: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Condensate pump and feed pump trip!- Turbine trips!

2

Page 3: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Condensate pump and feed pump trip!- Turbine trips!- Temperature and pressure in the primary loop is increasing!

3

Page 4: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Relief valves opens in the pressurizer !

OPEN

4

Page 5: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Control rods are inserted !

OPENINSERTED

5

Page 6: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Pressure in the primary loop is decreasing !

INSERTED

6OPEN

Page 7: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Emergency feed pump is now in operation !

INSERTED

OPERATION

7OPEN

Page 8: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Relief valve is closed !

INSERTED

OPERATION

8

Page 9: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Pressure in the primary loop is decreasing !

INSERTED

OPERATION

9

Page 10: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level in the stream generator is decreasing !

INSERTED

OPERATION

10

Page 11: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Pressure in the primary loop is decreasing !

INSERTED

OPERATION

11

Page 12: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

INSERTED

OPERATION

12

- Water level in the pressurizer is gradually increasing !- Pressure in the primary loop is decreasing !

Page 13: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

INSERTED

OPERATION

13NO WATER

- There is no water in the steam generator !

Page 14: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

INSERTED

OPERATION

14NO WATER

- Water level in the pressurizer is gradually increasing !- Pressure in the primary loop is decreasing !

Page 15: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

INSERTED

OPERATION

15NO WATER

- Why is pressure in the primary loop decreasing even though water level is increasing?

Page 16: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

INSERTED

OPERATION

16NO WATER

- Water level in the pressurizer is gradually increasing !- Pressure in the primary loop is decreasing !

Page 17: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Emergency core cooling system is now in operation !

INSERTED

OPERATION

WATER IS INJECTED

17NO WATER

Page 18: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !

INSERTED

OPERATION

WATER IS INJECTED

18NO WATER

Page 19: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- It might be dangerous if the amount of water is too much in the primary loop…

INSERTED

OPERATION

WATER IS INJECTED

19NO WATER

Page 20: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !

INSERTED

OPERATION

WATER IS INJECTED

20NO WATER

Page 21: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Emergency core cooling system is operated by the manual mode from now !

INSERTED

OPERATION

WATER IS INJECTED

21NO WATER

Page 22: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !

INSERTED

OPERATION

WATER IS INJECTED

22NO WATER

Page 23: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- One of two emergency core cooling systems is manually stopped and the injection water from the other one is reduced.

INSERTED

OPERATION

WATER IS INJECTED

23NO WATER

Page 24: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level in the pressurizer is increasing !- Pressure in the primary loop is decreasing !

INSERTED

OPERATION

WATER IS INJECTED

24NO WATER

Page 25: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level is reaching the top of the pressurizer !

INSERTED

OPERATION

WATER IS INJECTED

25NO WATER

FULL WATER

Page 26: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water in the pressurizer is full, but measurement data at other positions in the primary loop do NOT show consistent results…

INSERTED

OPERATION

WATER IS INJECTED

26NO WATER

FULL WATER

Page 27: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

INSERTED

OPERATION

WATER IS INJECTED

27NO WATER

FULL WATER

- Water level is at the top of the pressurizer !- Pressure of the primary loop is decreasing !

Page 28: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- Water level is at the top of the pressurizer !- Pressure of the primary loop is decreasing !- Water in the containment sump is moved to the auxiliary building.

INSERTED

OPERATION

WATER IS INJECTED

28NO WATER

FULL WATER

Page 29: 1. - Condensate pump and feed pump trip! -Turbine trips! 2

- The block values on the emergency feed water line pump have been CLOSE ! Why !

- Now it is OPEN !

INSERTED

OPERATION

WATER IS INJECTED

29FULL WATER