Upload
muhammad-rizki
View
18
Download
6
Embed Size (px)
DESCRIPTION
3G DT Verification Report Surrounding Jakarta Design Center 210814
Citation preview
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 1
3G DT Verification Report Surrounding Jakarta Design CenterTSEL JABODETABEK
August, 21st , 2014
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 2
3G Executive Summary
► Background :
- Pak Ade reported dropped call and access failure at surrounding Jakarta Design Center on last 2 days (19 th august 2014)
- DT conducted 3 Rounds from Plaza semanggi to Slipi on August 21 st , 2014.
► 3G DT Observation at route from plaza semanggi to slipi :
- RSCP observed in good level, dominant (0 to -65)
- ECNO observed in good quality avg ( -6 to -9) except front of PINTUTOLSLIPIDNSMW
- Found 6x CAD and 2x CAF :
CAD : All 6x Dropped Call happen at front of JDC / PINTU TOLL SLIPI due to dragging, late HO from JKTDESIGNCTRMW to PINTUTOLSLIPIDNSMW and PLNSLIPIMW to PINTUTOLSLIPIDNSMW due to Suspect alarm IP CLOCK LINK Failure.
CAF : All 2x Call Access Failure happen at front of JDC / PINTU TOLL SLIPI while UE serving by PINTUTOLSLIPIDNSMW due to suspect alarm IP CLOCK LINK Failure
► Solution
- Follow up to speedup clearing alarm IP Clock Link Failure.
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 3
Drive Test 3G Lock Long call RSCP vs ECNO at Surrounding JDC
RSCP ECNO Comment :
- RSCP observed in good level, dominant (0 to -65)
- ECNO observed in good quality avg ( -6 to -9) except front of PINTUTOLSLIPIDNSMW
- Found 6x CAD and 2x CAF :
CAD : All 6x Dropped Call happen at front of JDC / PINTU TOLL SLIPI due to dragging, late HO from JKTDESIGNCTRMW to PINTUTOLSLIPIDNSMW and PLNSLIPIMW to PINTUTOLSLIPIDNSMW due to Suspect alarm IP CLOCK LINK Failure.
CAF : All 2x Call Access Failure happen at front of JDC / PINTU TOLL SLIPI while serving by PINTUTOLSLIPIDNSMW due to suspect alarm IP CLOCK LINK Failure
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 4
Dropped Call Front Of Jakarta Design Center Comment :- From 3 Round trip
Drive testLong Call Lock 3G, every pass through front of JDC both from different direction DT having dropped call experience. - From observation
dropped call happen while UE Served with good level of RSCP but poor od ECNO due to dragging, late HO from PLNSLIPIMW or JKTDESIGNCENTERMW to PINTUTOLSLIPIDNSMW (always happened ).
- Intermittent active alarm IP Clock Link failure is as suspect root cause of dropped call issue.
Solution :Speedup clearing alarm IP
Clock Link Failure at PINTUTOLSLIPIDNSMW
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 5
Dropped Call Front Of Jakarta Design Center Comment :- From 3 Round trip
Drive testLong Call Lock 3G, every pass through front of JDC both from different direction DT having dropped call experience. - From observation
dropped call happen while UE Served with good level of RSCP but poor od ECNO due to dragging, late HO from PLNSLIPIMW or JKTDESIGNCENTERMW to PINTUTOLSLIPIDNSMW (always happened ).
- Intermittent active alarm IP Clock Link failure is as suspect root cause of dropped call issue.
Solution :Speedup clearing alarm IP
Clock Link Failure at PINTUTOLSLIPIDNSMW
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 6
Call Access Failure Front Of Jakarta Design Center Comment :- From 3 Round trip
Drive testLong Call Lock 3G , DT was having 2x call access failure experience. - From observation 2x
call access failure happen while UE Served by PINTUTOLSLIPIDNSMW.
- Intermittent active IP Clock Link Failure is as suspect root cause of call access failure issue.
Solution :Speedup clearing alarm IP
Clock Link Failure at PINTUTOLSLIPIDNSMW
HISILICON SEMICONDUCTORHUAWEI TECHNOLOGIES CO., LTD. Page 7