Substation Name 220KV SS Location MSETCL Relay Serial Number 0 CT Secondary Current 1 AmpLine Length of Protected Zone 100 kmLine Impedance of Protected Zone 10 OhmsCT Primary Current 1000 AmpPT Primary Voltage 400000 VoltPT Secondary Voltage 110 VoltLine Impedance of Protected Zone 2.75 OhmsEnable Zone1 YES Zone1 FW X1 1 OhmsR1ph 1.25 OhmsR1E 2.5 Ohmst1 for Zone1 0.04 secondsEnable Zone1X YES Zone1X FW X1A 1 OhmsR1Aph 1.25 OhmsR1AE 2.5 Ohmst1 for Zone1X 0.04 secondsEnable Zone2 YES Zone2 FW X2 2 OhmsR2ph 2.5 OhmsR2E 5 Ohmst2 for Zone2 0.342 secondsEnable Zone3 YES Zone3 RW X3 3 OhmsR3ph 5 OhmsR3E 10 Ohmst3 for Zone3 0.645 secondsRE/RL 1 XE/XL 1 X+A 20 OhmsX-A 20 OhmsRA1 5 OhmsRA2 10 OhmsAngle-A 30 DegreeRA1E 15 OhmsRA2E 20 OhmsAngle-AE 30 DegreeDir Line Ang1 (Ph-Ph) -30 DegreeDir Line Ang2 (Ph-Ph) 120 DegreeDir Line Ang1 (Ph-E) -30 DegreeDir Line Ang2 (Ph-E) 120 DegreeLine Angle 75 Degree