Upload
ali-ahmad
View
216
Download
0
Embed Size (px)
Citation preview
7/27/2019 8 Mcb Dms Line
1/5
GE Consumer & IndustrialPower Protection
GE imagination at work
sp
eiall
e
l
d
for
stic i talla
tio
s
New
DMS-lineMCB's and RCCB's / RCBO'sfor domestic installations
7/27/2019 8 Mcb Dms Line
2/5
Clear identification:
- Current rating - Tripping curve
- Interrupting capacity
- Selectivity class
- Product codification
- Laserprinting
DMS-line
Compliant with domestic standards EN/IEC 60898-1 and EN/IEC 61008/9-1
Bistable & dynamic clips
Ensure easy and reliable fixations
Flat and pozidrive screwdrivers
Quality clips
Easy fixation on DIN rail
User friendly and reliable
RCCB
No unwanted tripping
Flat and flush mounted orange push-button
GE imagination at work
Safety terminals:
protects the installer
by excluding all risks.Safe installation ensured
7/27/2019 8 Mcb Dms Line
3/5
DMS-line
Strong and stable terminals
Torque
2007
20082009
2010Time
3.5 Nm
Protected terminals IP 20
High capacity terminals
25mm2 or 2 x 10mm2 for MCB's
35mm2 or 2 x 16mm2 for RCCB's
Fork connection possibilities
BS
High torque terminals
3.5 Nm for MCB's
4.5 Nm for RCCB's
Abaco and Europe Line:
Insulated enclosures suited
for DMS-line installations
7/27/2019 8 Mcb Dms Line
4/5
Re
f.C
/4525
/E/EX1
.0E
d.
01
/07
Copyrig
htGEPowerContro
ls2007
40171
Performances
Thermal setting In 6-63A
230/400V
C
4.5kA / 6kA
3
25 or 2 x 10 mm2
1, 2, 3
115g/pole
Rated voltage AC Un
Tripping characteristic
Short-circuit capacity acc EN/IEC 60898-1
Selectivity class
Terminal capacity
Poles
Weight
DMS-line
MCB's EN/IEC 60898-14500
36000
3
MCB's - Characteristic B 4.5kA MCB's - Characteristic C 4.5kA
In (A) Cat. No. Ref. No.
6
10
16
20
25
3240
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
DG41 B06
DG41 B10
DG41 B16
DG41 B20
DG41 B25
DG41 B32DG41 B40
DG41 B50
DG41 B63
DG42 B06
DG42 B10
DG42 B16
DG42 B20
DG42 B25
DG42 B32
DG42 B40
DG42 B50
DG42 B63
DG43 B06
DG43 B10
DG43 B16
DG43 B20
DG43 B25
DG43 B32
DG43 B40
DG43 B50
DG43 B63
690668690669690670690671690672
690673690674690675690676690677690678690679690680690681690682690683690684690685690686690687690688690689690690
690691690692690693690694
In (A) Cat. No. Ref. No.
6
10
16
20
25
3240
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
DG41 C06
DG41 C10
DG41 C16
DG41 C20
DG41 C25
DG41 C32DG41 C40
DG41 C50
DG41 C63
DG42 C06
DG42 C10
DG42 C16
DG42 C20
DG42 C25
DG42 C32
DG42 C40
DG42 C50
DG42 C63
DG43 C06
DG43 C10
DG43 C16
DG43 C20
DG43 C25
DG43 C32
DG43 C40
DG43 C50
DG43 C63
690695690696690697690698690699
690700690701690702690703690704690705690706690707690708690709690710690711690712690713690714690715690716690717
690718690719690720690721
12
12
12
12
12
1212
12
12
6
6
6
6
6
6
6
6
6
4
4
4
4
4
4
4
4
4
Pack.
MCB's - Characteristic B 6kA MCB's - Characteristic C 6kA
In (A) Cat. No. Ref. No.
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
DG61 B06
DG61 B10
DG61 B16
DG61 B20
DG61 B25
DG61 B32
DG61 B40
DG61 B50
DG61 B63
DG62 B06
DG62 B10
DG62 B16
DG62 B20
DG62 B25
DG62 B32
DG62 B40
DG62 B50
DG62 B63
DG63 B06
DG63 B10
DG63 B16
DG63 B20
DG63 B25
DG63 B32
DG63 B40
DG63 B50
DG63 B63
690722690723690724690725690726690727690728690729690730690731690732690733690734690735690736690737690738690739690740690741690742690743690744690745690746690747
690748
In (A) Cat. No. Ref. No.
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
6
10
16
20
25
32
40
50
63
DG61 C06
DG61 C10
DG61 C16
DG61 C20
DG61 C25
DG61 C32
DG61 C40
DG61 C50
DG61 C63
DG62 C06
DG62 C10
DG62 C16
DG62 C20
DG62 C25
DG62 C32
DG62 C40
DG62 C50
DG62 C63
DG63 C06
DG63 C10
DG63 C16
DG63 C20
DG63 C25
DG63 C32
DG63 C40
DG63 C50
DG63 C63
690553690554690555690556690557690558690559690560690561690569690586690570690571690572690573690574690575690576690577690578690579690580690581690582690583690584
690585
12
12
12
12
12
12
12
12
12
6
6
6
6
6
6
6
6
6
4
4
4
4
4
4
4
4
4
Pack.
7/27/2019 8 Mcb Dms Line
5/5
Re
f.C
/4525
/E/EX1
.0E
d.
01
/07
Copyrig
htGEPowerContro
ls2007
40171
DMS-line
Performances
Thermal setting in 25 - 63A
30-300mA
2P: 230-400V
Inc = 6000A at 230V fuse 63A gG
AC: 250A 8/20s
35mm2 or 2 x 16mm2
2
2P: 210g
Residual Current I m
Rated voltage AC Un
Short-circuit capacity
Nuisance tripping resistance
Terminal capacity
Poles
Weight
RCCB's EN/IEC 61008-1 - Type AC
RCCB's - Type AC
In (A) Cat. No. Ref. No. Pack.
25
40
63
25
4063
25
40
63
25
40
63
DCG225/030
DCG240/030
DCG263/030
DCG425/030
DCG440/030DCG463/030
DCG225/300
DCG240/300
DCG263/300
DCG425/300
DCG440/300
DCG463/300
690776
690778
608413
608415
608417608419
690777
690779
608414
608416
608418
608420
690776690778608413608415608417608419690777690779608414608416608418608420
Performances
Thermal setting in 6 - 40A30mA
2P: 230-400V
Inc = 6000A
AC: 250A 8/20s
35mm2 or 2 x 16mm2
2
2P: 210g
Residual Current I m
Rated voltage AC Un
Short-circuit capacity
Nuisance tripping resistance
Terminal capacity
Poles
Weight
RCBO's EN/IEC 61009-1 - Type AC
6
6
6
6
66
6
6
6
6
6
6
In (A) Cat. No. Ref. No. Pack.
6
10
16
20
25
32
40
DDM60C06/030
DDM60C10/030
DDM60C16/030
DDM60C20/030
DDM60C25/030
DDM60C32/030
DDM60C40/030
690788
690789
690790
690791
690792
690793
690794
690788690789690790690791690792690793690794
6
6
6
6
6
6
6
RCBO's - Type AC
GE POWER CONTROLSInternational SalesNieuwevaart 51B-9000 Gent - Belgium