A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 2 o f 13 R e l ease , 22 -Ju l y -2010
Publication Information
2007-2010 Harris Corporation. All rights reserved. Harris Proprietary Information.
This document and its contents are considered confidential and proprietary by HarrisCorporation. This publication, or any part thereof, may not be reproduced in any form,by any method, for any purpose, without the written consent of Harris Corporation.
Contact Harris Corporation for permission to use materials as well as guidelinesconcerning foreign language translation and publication. A reasonable number ofcopies of this document may be made for internal use only. All others uses areillegal.
This publication is designed to assist in the use of the product as it exists on the dateof publication of this manual, and may not reflect the product at the current time or anunknown time in the future. This publication does not in any way warrant descriptionaccuracy or guarantee the use for the product to which it refers.
Harris Corporation reserves the right, without notice to make such changes inequipment, design, specifications, components, or documentation as progress maywarrant to improve the performance of the product.
TrademarksThe Harris logo, assuredcommunications, D-Series and ADC are trademarksof Harris Corporation or its subsidiaries. Microsoftand Windowsare registeredtrademarks of Microsoft Corporation. All other marks are the property of theirrespective owners.
Contact Information
Contact Harris Corporation at:
The Americas
9800 S. Meridian Blvd
Englewood, CO 80112 USA
Ph +1 303 476 5000 Fax +1 303 476 5004
England
Eskdale Road
Winnersh Triangle
Reading, Berkshire
England RG41 5TS
Ph +44 (0) 118 9648000
France
Immeuble le Signac
5 alle des Bas Tilliers
92 230 Gennevilliers, FranceTel: +33 01 47 92 44 00 Fax: +33 01 47 98 29 67
Australia/Pacific
Level 1, 14 Rodborough Road, Frenchs Forest
NSW 2086 Australia
Ph +61 (2) 9975 9700 Fax +61 (2) 9975 3519
7/31/2019 ADC Rackmount Reference g4
3/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence C on ten ts
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 3 o f 13 R e l ease , 22 -Ju l y -2010
Contents
About this Manual............................................................................... 5Audience ..................................................................................................................................... 5Automation System-specific Documentation Sets ...................................................................... 5Measurement Standards............................................................................................................. 5Product Unpacking Notes ........................................................................................................... 6
Standard ADC System Hardware.......................................................7Equipment and Dimensions ........................................................................................................ 7Harris Supplied Items.................................................................................................................. 7Miscellaneous Items.................................................................................................................... 8
Supported Peripheral Control Devices ...............................................9Operator Control Panel (OCP).................................................................................................... 9
Summary of Panel Features ................................................................................................. 10Specifications........................................................................................................................ 10
Ingest Control Panel (ICP) ........................................................................................................ 10Summary of Panel Features ................................................................................................. 11Specifications........................................................................................................................ 11
Rackmounting .................................................................................. 12The Device Controller Package ................................................................................................ 12
Mounting Hints ...................................................................................................................... 12Rackmounting Sequence .......................................................................................................... 12
7/31/2019 ADC Rackmount Reference g4
4/13
7/31/2019 ADC Rackmount Reference g4
5/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence A bou t th i s Manua l
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 5 o f 13 R e l ease , 22 -Ju l y -2010
About this Manual
Audience
This manual is intended as a general reference and for use by engineers ortechnicians when installing Harris professional automation computers.
Automation System-specific DocumentationSets
Common Hardware Platform documentation sets are collated based on theautomation system being installed.
ADC playout automation
CHP Device Controller 2RU Hardware Reference
CHP Device Controller 4RU Hardware Reference
CHP Cabling Standards Reference
ADC CHP Board Set Reference
ADC Hardware Control Panels Reference ADC System Rackmount Reference
Measurement Standards
The following measurement standards are used in this manual:
Rack Unit (RU) is an Imperial standard measurement for device height. (Whilealso seen as U.) [1RU = 44.45mm = 1.75 inches]
19 Rack Standard is an international standard for racking width. [19 Rackmount
standard = 482.6mm] Other measures for in-document conversion: (1m = 3.281ft), (0.3048m = 1ft),
(25.4mm = 1in), (1kg = 2.205lb)
Website for length & weight conversions: http://www.convert-me.com/en/convert
7/31/2019 ADC Rackmount Reference g4
6/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence A bou t th i s Manua l
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 6 o f 13 R e l ease , 22 -Ju l y -2010
Product Unpacking Notes
Thoroughly inspect all articles immediately upon receipt. Any damage discoveredshould be cause for a damage claim against the carrier.
7/31/2019 ADC Rackmount Reference g4
7/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence S tanda rd A D C S ys tem H a rdw are
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 7 o f 13 R e l ease , 22 -Ju l y -2010
Standard ADC System Hardware
Equipment and Dimensions
This section describes the hardware components for the deployable CHP DeviceController and dimensions for the overall ADC Playout Automation Systemequipment.
Hardware Height Width (FacePlate)
Depth
CHP DeviceController 4RU
7
(17.78 cm) (4RU)
19
(48.26 cm)
20
(50.8 cm)
CHP DeviceController 2RU
3.5
(8.89 cm) (2RU)
19
(48.26 cm)
19
(48.26 cm)
Transfer Switch 1.75
(4.44 cm) (1RU)
19
(48.26 cm)
3.25
(8.25 cm)
Cloning ControlPanel
1.75
4.44 cm) (1RU)
19
(48.26 cm)
20
(50.8 cm)
Relay Panel 1.75
(4.44 cm) (1RU)
19
(48.26 cm)
1.25
(3.16 cm)
GPI Breakout 1.75
(4.44 cm) (1RU)
19
(48.26 cm)
1.75
(4.44 cm)
24 port 1000 Base-TNetwork Switch50739
1.75
(4.45 cm)
19
(48.23 cm)
Due to continuous product improvements, dimensions may change, particularlywith respect to the client PC. Contact your Harris Project Manager for moreinformation.
Unless otherwise requested, customers supply their own monitors and KVMswitch.
Harris Supplied Items
The following cables are supplied with Harris components (if ordered):
7/31/2019 ADC Rackmount Reference g4
8/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence S tanda rd A D C S ys tem H a rdw are
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 8 o f 13 R e l ease , 22 -Ju l y -2010
Client Control Panel MCS Transport
Harris supplies the interconnect cable which runs from the clients transport panel toCom Port 1. This is a 9-pin male to female cable approximately 6 feet (2 meters)long and is wired pin-to-pin.
Media Client Control Panel MCS-Clip24
Harris supplies the interconnect cable which runs from the MCS-Clip24 configuarableLCD button panel to Com Port 1. This is a 9-pin male to female cable approximately6 feet (2 meters) long and is wired pin-to-pin.
File Server Interconnection
If you have purchased two File Servers with co-standby File Server backup, Harrissupplies the interconnect cable between File Servers which enables automaticmirroring.
RS-232 to RS-422 Converters
Harris supplies RS-232 to RS-422 adapters for certain devices that support only RS-
232 serial protocol.
Miscellaneous Items
Devices
Prepare all devices such as VTRs, videodisks, switchers and cart machines forautomation installation using user notes supplied by Harris.
Important:
Confirm device model/version and obtain correct manufacturer's software andfirmware on disk/proms as needed.
Ensure that any internal DIP switches are set for the correct communicationparameters (Baud rate, parity, etc).
Printer(s)
Harris does not supply any printers with your system. You may, however, purchase aprinter and connect it to the File Server or Media Client workstations parallel port.Optionally, you may choose to provide a print server available on the network toconnect to the printer. A standard Windows driver for any installed printer(s) shouldbe available for installation on Harris computers as needed.
7/31/2019 ADC Rackmount Reference g4
9/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence S uppo r ted P e r i phe ra l C on t ro l D ev i ces
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 9 o f 13 R e l ease , 22 -Ju l y -2010
Supported Peripheral ControlDevices
Operator Control Panel (OCP)
The Operator Control Pane is a mid-sized desktop controller that provides instantaudio or video playback and control for broadcast automation, post production andother applications. This panel gives operators a choice in controlling automationenvironments by providing unambiguous button control in addition to conventionalkeyboard and mouse operations.
Panel Functions
The OCP comes with 24, hi-res, remotely-relegendable 64 x 32 LCD buttons, 10bank buttons, and 17 additional function and navigation switches.
The hi-res LCD buttons can display text (up to 40 characters) and graphics using builtin command driven serial interfaces. They integrate a graphical LCD with RGBbacklighting, and are capable of displaying up to 64 colors. Software controls theinterface, display and backlighting. Data only needs to be transmitted when a changeis made to the display or background colors.
These LCD buttons can be programmed to provide a range of functions. Mostcommonly used when breakdowns or other failures occur, each button on the OCP
can call up actions needed in a hurry.For example, a button can be configured to:
Cut back to Network, or even backup device with a ready content.
Display a full-screen apology slide or trigger a caption for missing audio.
7/31/2019 ADC Rackmount Reference g4
10/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence S uppo r ted P e r i phe ra l C on t ro l D ev i ces
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 10 o f 13 R e l ease , 22 -Ju l y -2010
Summary of Panel Features
24 LCD buttons
4x10, 3x8, 2x7, Icons
64 colors
23 additional buttons 18 have LEDs - 5 can be used to menus
2 line x 40 character display
Up to 10 banks of 6 buttons can be configured (i.e. the top row of LCD buttons onthe panel) and assigned to specific channels to provide a range of standardactions.
The remaining three rows of 6 buttons each (18 buttons) can be programmed toprovide a range of standard actions.
Specifications
The following table provides a brief list of specifications for a Ingest Control Panel.
Specification Description
Size 9.25 x 10.0 x 2.5
Weight 17 lbs (37.49KG)
Power Requirements The ICP comes with a universal, 12 volt DC switchingpower supply. If you need a power cord specific to yourlocation, please contact your local distributor.
Warning: Using a power supply other than the unitspecified can result in damage to the panel and/or otherequipment which is not covered by the manufactures
Warranty.
Typical Location In close proximity to the operator workstation.
MountingRequirements
No mounting is required. Since this is a desktop unit,only sufficient desk space is required.
Ingest Control Panel (ICP)
The Ingest Control Panel (ICP) provides basic transport and jog/shuttle controls in acompact desktop unit. This panel gives operators a choice in controlling ingest
environments by providing desktop device transport button control in addition to anautomation GUIs Device Control Interface and a broadcast devices conventionaltransport controls.
When used in conjunction with an automation playout or ingest workstation, theworkstation displays the events to be controlled and the ICP provides a hands-onuser interface
7/31/2019 ADC Rackmount Reference g4
11/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence S uppo r ted P e r i phe ra l C on t ro l D ev i ces
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 11 o f 13 R e l ease , 22 -Ju l y -2010
Summary of Panel Features
Ingest Control Panel features include:
Sony Jog Shuttle knobThe jog/shuttle mechanism is a weighted jog wheel and a concentric shuttle ring.
18 control buttons
5 dedicated transport controls
Can be directly connected to workstation or ganged to Operator Control Panel
SpecificationsThe following table provides a brief list of specifications for a Ingest Control Panel.
Specification Description
Size 11.5 x 8.0 x 2.5
Weight 13.23 lbs (KG)
Power Requirements The ICP comes with a universal, 12 volt DC switchingpower supply. If you need a power cord specific to yourlocation, please contact your local distributor.
Warning: Using a power supply other than the unitspecified can result in damage to the panel and/or otherequipment which is not covered by the manufacturesWarranty.
Typical Location In close proximity to the operator workstation.
MountingRequirements
No mounting is required. Since this is a desktop unit,only sufficient desk space is required.
7/31/2019 ADC Rackmount Reference g4
12/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence R ackmoun t i ng
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 12 o f 13 R e l ease , 22 -Ju l y -2010
Rackmounting
The Device Controller Package
Device Controller(s) are rack mountable devices and ship with rack rails. Transferswitches, relay panels, GPI breakouts, network hub(s) and keyboard/video/mouse(KVM) switch are supplied with rack mount ears for easy installation.
Mounting Hints
17 monitors come standard with the Harris system. If you require smaller or
larger monitors, this must be specified at the time of the order. Mount the 8-port relay panels and GPI breakouts in the back of the rack. The
relay panels are connected to the transfer switch or to the cloning panel if cloninghas been ordered as an option.
Your Device Controller comes with a rack size keyboard, ideal for storage in akeyboard drawer. However, both the keyboard drawer and rack mount kits formonitors and client PCs must be purchased separately if needed.
Appropriate power cords are provided for all equipment. If any, or all, of thepower cords supplied with the system are incorrect, contact Harris Automation forassistance.
While most, if not all, equipment is equipped with auto sensing power supplies, itis essential that care be taken to ensure that any line voltage settings present areproperly set prior to applying power to any equipment.
Rackmounting Sequence
Install your Device Controller(s), transfer switch, keyboard/video/mouse switch,Application/File Server(s) and network hub in the same rack, or in adjacent racks.This rack should also contain an uninterruptible power supply (UPS) for your DeviceController(s).
We recommend installing the equipment in a least used to most used
configuration from the top of the rack to the bottom, with user controls convenientlyplaced. If this configuration is followed, system components are installed from thetop to the bottom of the rack in this order:
Application/File Server (Installation and setup of this sever are addressed underseparate documentation.)
Network hub(s)
Monitor
7/31/2019 ADC Rackmount Reference g4
13/13
A D C p l ayou t au toma t i on sys temR ackmoun t R e fe rence R ackmoun t i ng
C opy r i gh t 2007 -2010 H a r r i s C o rpo ra t i on H a r r i s P rop r i e ta ry In fo rma t i on
P age 13 o f 13 R e l ease , 22 -Ju l y -2010
Transfer switch
Keyboard/Video/Mouse switch
Keyboard and mouse
Main Device Controller
Backup Device Controller
UPS
Sample Rack Configuration
The following is a sample rack configuration of the Harris automation equipment.