1. 1 2013 2014 ZKUENOSTI A PRAKTICK UKZKY Z REALIZAC PASIVNCH A
TM NULOVCH DOM www.abatelier.cz Ale Brotnek 2012 CESTY K NEZVISL
ARCHITEKTUE.
2. 2 EPBD 2 Tm nulov dm CZ 2013 S MINIMEM ENERGIE Z OZE MINIMLN
POHODL! Plusov nezvisl dm 1984 ektro- spotebie VZT Ohev TUV Vytpn
Pasivn dm Tm nulov dm EU Nulov dm V jak ARCHITEKTUE se ilo ped 150
lety Z OBNOVITELNCH ZDROJ? ohev UV+ vytpn z OZE 0 50 100 150 200
250 Zstavba 20.stolet celkovenergie[kWh/m2a] Nzkoenergetick dm
Zstavba 19.stolet SN 730540 2011 cca15-50kWh/(m2a) Pomal rozvoj dle
mstnch podmnek a zdroj s prakticky bezodpadovmi technologiemi v du
s ekosystmem a respektovnm PIROZENCH LIMIT PROSTED! ARCHITEKTURA
BYLA PASIVN NZKOENERGETICK www.abatelier.cz ZDROJ : CPD
3. 3 Plusov nezvisl dm 1984 ektro- spotebie VZT Ohev TUV Vytpn
Pasivn dm Tm nulov dm EU Nulov dm ohev UV+ vytpn z OZE 0 50 100 150
200 250 Zstavba 20.stolet celkovenergie[kWh/m2a] 180-240kWh/(m2a)
Nzkoenergetick dm Zstavba 19.stolet SN 730540 2011
cca15-50kWh/(m2a) EPBD 2 Tm nulov dm CZ 2013 Jak je ddictv
ARCHITEKTURY 20.stol. v e zdnliv NEONEOMEZENCH ZDROJ? Rozvoj
technologi otevel netuen monosti, ale technicky architekturu
ponechal na rovni 19.stol se zabezpeenm pohodl jen dky obrovskmu
nrstu spoteby energie a dky IGNOROVNM LIMIT PROSTED. ARCHITEKTURA
ZVISL NA FOSILNCH ZDROJCH S MAXIMEM ENERGIE PROBLEMATICK IVOTN
POHODL! Od prvn ropn krize a rstu cen energie zhorovn kvality
vnitnho prosted na NEBEZPEN K POBVN. ZDROJ : CPD
4. 4 Nzkoenergetick zatky 80 kWh/m2 za rok 1990-93 50 kWh/m2 za
rok 1996-99 36 kWh/m2 za rok 1997-00 1984 35 kWh/m2 za rok
5. 5 Na prvnm mst lze doshnout nejefektivnji snen energetick
nronosti objektu ZATEPLENM! (u rekonstrukc jak to jen dovol
technick een domu) Vsledn vlastnosti domu ur tvar, kvalita oken a
proveden Bez zen vmny vzduchu s rekuperac nelze zajistit kvalitu
vnitnho prosed Na konci je dilema, jak zajistit zbytkovou
MINISPOTEBU energie? Nejlpe z obnovitelnch zdroj (optimln k danm
podmnkm) Autor tech graf: Ing. V. ra JAK JE LOGICK POSLOUPNOST
OPATEN PI NAVRHOVN NED a PD rozvaha z roku 2001
6. 6 CESTA EFEKTIVITY A ZJEDNODUOVN NED+PD a VZT Prvn vvojov
rekuperan jednotka upraven pro prvn dva NE RD 1995 1996
7. 7 NVRAT K ODDLEN ZENHO VTRN S REKUPERAC (OVLDANHO IDLEM CO2
) OD VYTPN TEPLOVODNM PANELEM S TERMOSTATEM A INTEGROVANOU VSTKOU
PVODU VZDUCHU CESTA EFEKTIVITY A ZJEDNODUOVN VZT PODSTROPN ROZVODY
A ODDLEN VTRN A VYTPN +TERMIKA A DEVO Souasn jednotka se snadno
istitelnmi plastovmi rozvody
8. 8 Markta Spodniakov, Pavel Spodniak a Ale Brotnek DM U
MODRHO KKU 2007-10
9. 9 DM U MODRHO KKU ZDROJ TEPLA - krbov vloka Hoxter WK8 S
OHEVEM VODY +IZT+ TEPLOVODN SLUNEN KOLEKTORY CESTA EFEKTIVITY A
ZJEDNODUOVN OBNOVITELNCH ZDROJ ENERGIE
10. 10 DM U MODRHO KKU ZDROJ TEPLA - krbov vloka Hoxter WK8 S
OHEVEM VODY +IZT+ TEPLOVODN SLUNEN KOLEKTORY CESTA EFEKTIVITY A
ZJEDNODUOVN OBNOVITELNCH ZDROJ ENERGIE
11. 11 Markta Spodniakov, Pavel Spodniak a Ale Brotnek DM U
MODRHO KKU Hmota do konstrukce domu MASIVN HLINN OMTKY
12. 12 Markta Spodniakov, Pavel Spodniak a Ale Brotnek DM U
MODRHO KKU Hmota do konstrukce domu MASIVN HLINN OMTKY
13. 13 Markta Spodniakov, Pavel Spodniak a Ale Brotnek DM U
MODRHO KKU Hmota do konstrukce domu MASIVN HLINN OMTKY
14. 14 Markta Spodniakov, Pavel Spodniak a Ale Brotnek DM U
MODRHO KKU Zdroj tepla - krbov vloka Hoxter WK8 S OHEVEM VODY
15. 19 KOMPOSTOVAC TOALETA - ET 50% SPOTEBY VODY
16. 20 TM PASIVN RD dle PHPP 25 kWh/(m2a), A/V 0,83 , TEST
TSNOSTI 0,33h-1 STAVBA 2007-9
17. 21
18. 22
19. 23 Kostomlaty 2007- 09 TM PASIVN RD dle PHPP 25 kWh/(m2a),
A/V 0,83 , TEST TSNOSTI 0,33h-1 STAVBA 2007-9 ZA ROK SPOTEBA NA
OHEV VODY A DOVYTPN 1m3 DEVA
20. 24 Kniha rozhovor s investory - Klra Brotnkov, Ale Brotnek
REFLEXE NAVRHOVN A UVN OD PRVNHO NED V R (1995) DO SOASNOSTI PD
(2012)
21. 25 Rekonstrukce podle princip pasivnho stavn Jak dalece je
mon se pi rekonstrukci piblit parametrm 15 kWh/(m2a ) ? Dostavba a
rekonstrukce jedn budovy v rmci kolnho arelu Z Mstsk sti
Praha-Slivenec ABATELIER Ale Brotnek, Jan Preisler, Jan Mrton, Ji
ech
22. 26 Pvodn poteba tepla na vytpn 203 kWh/m2/rok Dosaen poteba
tepla na vytpn 21 kWh/m2/rok Byla to drah rekonstrukce? Rozpoet
pvodn bn rekonstrukce 11mil Rozpoet pasivn rekonstrukce pedpokldan
12mil Ve vbrovm zen vysouten cena rekonstrukce za 11,3 mil spora
89,8 % Jde ale jen o spory energie? Dostavba a rekonstrukce jedn
budovy v rmci kolnho arelu Z Mstsk sti Praha-Slivenec
23. 27 Dostavba a rekonstrukce koln budovy Z Slivenec
Rekonstrukce podle princip pasivnho stavn Vzduchotechnika V pate,
kde jsou kabinety a uebny, je vzduchotechnika piznan viditeln >
obtn zakryt, vtvarn prvek, edukan el na pvodu i odvodu jsou osazeny
uzavrac klapky ovldan ze tdy > ppad, e nejsou ve td ci, nen tda
provtrvna
24. 28 Dostavba a rekonstrukce koln budovy Z Slivenec
Rekonstrukce podle princip pasivnho stavn Vzduchotechnika pvod a
odsvn vzduchu jsou vdy na protilehl stran tdy rozvody do
jednotlivch ueben a kabinet zstaly piznan
25. 29 Prbh koncentrac CO2 bhem SIMULOVAN VYUOVAC HODINY pi
tiskov konferenci 18.12.2010 Experimentln zkouka kvality vnitnho
prosted DLE JEN LZE ODVODIT, E BHEM DALCH 15minut VYSTOUPALA
KONCENTRACE CO2 NA 2500ppmMIC ZAZEN JI NEDOKE VY KONCENTRACE MIT PO
VYPNUT ZEN VMNY VZDUCHU S REKUPERAC NASTAL PRUDK NRST KONCENTRACE
CO2 A BHEM 45minut DOSHL 2000ppm PI ZATKU TISKOV KONFERENCE BYLO V
PROSTED UEBNY NAMENO 550ppm OPTIMLN KONCENTRACE CO2 DO 700-800 ppm
venkovn prosted dve 330ppm, dnes 450ppm (pi inverzi tak i 700ppm)
do 1000-1100 ppm - pijateln, ale ji s pachy a odry do 1500 ppm -
sniovn koncentrace, nava a ospalost nad 1500 ppm prohlubovn navy a
dle ji i kody na zdrav NA KOLIK SE ZVILA KONCENTRACE CO2 ppm po
45minutch?
26. 30 Vsledky vzkumu vtrn v rakouskch kolch NAPROSTOU V TINU
AKTIVNHO VYU OVACHO ASU TRV D TI V PROST ED, KTER VE KOLCH NEM
NIKDY NASTAT A KTER ODPORUJE VYHLCE O OBECN TECHNICKCH PODMNKCH VE
VSTAVB ! PROST ED ZDRAV K POBVN NASTV POUZE V DOB KDY VUKA NEPROBH
Simulace pirozenho vtrn uebny pro rzn varianty vtrn a jeho dopadu
na koncentraci oxidu uhliitho. Vsledky simulace ukazuj, e i v
idelnch ppadech vtrn pestvky nedochz k dostatenmu provtrn prostoru.
(Men kvality vzduchu v kolch v Hornm Rakousku, Amt der O. LR., Abt.
Umwelt- und Anlagentechnik) ZDROJ: PUBLIKACE CENTRA PASIVNHO DOMU -
Nucen vtrn s monost rekuperace odpadnho tepla v objektech pro
vzdln
27. 31 Vsledky vzkumu vtrn v Rakouskch kolch Takov je i stav ve
VECH eskch kolch, kde nen zajit no zen v trn !
28. 32 KONCENTRACE CO2 NAD 1500-5000ppm NA PRACOVITI I PI
STUDIU 1. NEPJEMN ODRY, PACHY A OSPALOST 2. SNIOVN SOUSTEDN,
POZORNOSTI A VKONOSTI = snen efektivita prce i vuky 3. SNIOVN
SCHOPNOSTI ZAPAMATOVAT SI INFORMACE KONCENTRACE CO2 NAD
1500-5000ppm PI ODPOINKU A VE SPNKU 1. POCITY NEDOSPALOSTI, NAVA A
NSLEDN USNN BHEM STEREOTYPNCH INNOST, PI TEN A PI ZEN MOTOROVHO
VOZIDLA. 2. PI VYCH KONCENTRACCH BOLESTI HLAVY, ZVYOVN KREVNHO
TLAKU, KTER ME POSTIHOVAT POKOZOVN MOZKOVCH BUK 3. PORUCHY PAMTI A
NPADN KORELACE SE ZVYOVNM VSKYTU MOZKOVCH NEMOC VE SPOLENOSTI
(nap.Alzheimerova choroba, v r. 2000 zhruba 5070 tisc osob, v r.
2008 ji 120 tisc osob, (zdroj MZ) pibv alergik, ) 4. PORUCHY
IMUNITY, ZVEN PROBLMY ALERGIK A ASTMATIK. JAK ME MT NEKVALITN
PROSTED ARCHITEKTURY DSLEDKY A NSLEDKY? 1990 Ulm-Eggingen. Martin
Wamsler Architektengemeinschaft Reiter & Rentzsch
29. 33 200520052013 2007 EPBD 2 Tm nulov dm CZ 2013 Plusov
nezvisl dm 1984 ektro- spotebie VZT Ohev TUV Vytpn Pasivn dm - 90%
do15kWh/(m2a) Tm nulov Dm EU Nulov dm JAK VELK POTENCIL SPOR M
SOUASN ARCHITEKTURA? ohev UV+ vytpn z OZE 0 50 100 150 200 250
Zstavba 20.stolet celkovenergie[kWh/m2a] - 80% 180-240kWh/(m2a)
Nzkoenergetick dm do50kWh/(m2a) Zstavba 19.stolet SN 730540 2011
do90kWh/(m2a) cca15-50kWh/(m2a) 1984 1990 1995 1996 2003 PO PRVN
ROPN KRIZI ARCHITEKTURA UKZALA, E M POTENCIL SPOR 2001 80 -- 90%
KONCEPT PASIVNHO DOMU S MINIMEM SPOTEBY ENERGIE POSKYTNE ZDRAV
POHODL S VYM KOMFORTEM ZDROJ : CPD
30. 34 www.abatelier.cz SMRNICE EU = STANOVEN SPOLENCH CL A ZJM
SVRCHOVAN STTY (PODLE SVCH PRIORIT) ODPOVDN HLEDAJ PROSTEDKY K
JEJICH NAPLNN dle svch specifik HLAVN CL - SNIT SPOTEBU ZDROJ (PEZ)
NA MINIMUM SPOLEN ANCE - MINIMUM SPOTEBY (NEN TK) POKRT OZE
Performance of Buildings Directive (EPBD2) 2010/31/EU 19. 5 2010
Zdroj: (EPBD2) 2010/31/EU 19. 5 2010
31. 35 www.abatelier.cz Pi provozu budov se spotebovv 40%
energie. K tomu stopa celho cyklu ivota stavby (vroba materil,
doprava, vstavba, drba, reinvestice a likvidace stavby) = vce ne
50% energie. Souasn architektura je nejvt ekologickou stopou na
civilizace, a proto tak nejvt nadj, pokud dokeme vyuit POTENCILU
SPOR! Zdroj: Eurostat, zvry Paesovi komise 1 Paesova komise 1:
MONOSTI ENERGETICK RENOVACE BUDOV JSOU DVAKRT VT NE CEL SPOR O
LIMITY TBY UHL JAK SE PODL ARCHITEKTURA NA SPOTEB ENERGIE?
32. 36 BALKY SLMY POUZE JAKO NENOSN IZOLACE V EVROP rakousk
model -vpl ze slmy v nosn konstrukci Ale Brotnek
33. 37 COUNTRY LIFE Nenaovice 2002-05 DOSTAVBA SE SPOLEENSKM
SLEM (SOBOTN KAPL) Ale Brotnek
34. 38 VYUIT BALK ZE SLMY KE STAVB PILO Z NEBRASKY V USA - -
SLMA JAKO NOSN PRVEK Ale Brotnek
35. 39 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
36. 40 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
37. 41 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
38. 42 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
39. 43 HRADANYU TINOVA II. 2006-10 AUTOI: A.BROTNEK,J.PRAISLER
PROLNN IZOLACE Z BALK S NEHRANNOU KULATINOU KONSTRUKCE
40. 44
41. 45 POCTIV ZJITN, E POKUS O ZDRAV BYDLEN BEZ ZENHO VTRN KON
RNO V LONICI ATMOSFROU S 2500ppm
42. 46 bonus stavebn firmy anda RDLO - 2010-11 STAVT PED
KONSTRUKCI, DOPLOVAT JET DAL IZOLAC
43. 47 RDLO - 2010-11 RATMICE 2011-14 DOPLOVAT JET DAL IZOLAC
PED, NEBO ZA PLYNOTSNOU VRSTVOU?
44. 48 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 mrn
poteba tepla na vytpn dle PHPP: 18-2318-23 kWh/(m2 a)
45. 49 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 mrn
poteba tepla na vytpn dle PHPP: 18-2318-23 kWh/(m2 a)
46. 50 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 mrn
poteba tepla na vytpn dle PHPP: 18-2318-23 kWh/(m2 a) 2kWp
47. 51 Dm .05 pro EKOPARK O.P.S . PROSPERITA 2010 A.BROTNEK
KONSTRUKCE STN Z NOSN SLMY SPOLUPRCE J.MRTON, J.ECH
48. 52 VUT-PORN ZKOUKY obvodovch stn pro NE/PAS domy s tepelnmi
izolacemi na bzi slmy SPOLUPRCE A.BROTNEK J.MRTON, J.ECH VYBRAN
VLASTNOSTI PRODNCH A DALCH STAVEBNCH MATERIL, STAVEBNCH PRVK A
BUDOV z programu Efekt, MPO R. USA REI 120 min CZ ??? SKLADBA 01 -
NOSN SLAMN STNA - RM 3x3 m 30 MM VNJ VPENN OMTKA 500 MM SLAMN BALKY
ZTLAEN NA 91KG/M3 50 MM VNITN HLINN OMTKA TVRSTV
49. 53 VUT-PORN ZKOUKY obvodovch stn pro NE/PAS domy s tepelnmi
izolacemi na bzi slmy SPOLUPRCE A.BROTNEK J.MRTON, J.ECH VYBRAN
VLASTNOSTI PRODNCH A DALCH STAVEBNCH MATERIL, STAVEBNCH PRVK A
BUDOV z programu Efekt, MPO R. SKLADBA 01 - NOSN SLAMN STNA - RM
3x3 m
50. 54 VUT-PORN ZKOUKY obvodovch stn pro NE/PAS domy s tepelnmi
izolacemi na bzi slmy SPOLUPRCE A.BROTNEK J.MRTON, J.ECH VYBRAN
VLASTNOSTI PRODNCH A DALCH STAVEBNCH MATERIL, STAVEBNCH PRVK A
BUDOV z programu Efekt, MPO R. SKLADBA 01 - NOSN SLAMN STNA - RM
3x3 m
51. 55 VUT-PORN ZKOUKY obvodovch stn pro NE/PAS domy s tepelnmi
izolacemi na bzi slmy SPOLUPRCE A.BROTNEK J.MRTON, J.ECH VYBRAN
VLASTNOSTI PRODNCH A DALCH STAVEBNCH MATERIL, STAVEBNCH PRVK A
BUDOV z programu Efekt, MPO R. REI 120 min (1 h 26 min.)SKLADBA 01
- NOSN SLAMN STNA - RM 3x3 m
52. 56 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 mrn
poteba tepla na vytpn dle PHPP: 18-2318-23 kWh/(m2 a)
53. 57 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 mrn
poteba tepla na vytpn dle PHPP: 18-2318-23 kWh/(m2 a) VKON 12 kWp
ZNAMEN REZERVU PRO DM SOBSTAN PLUSOV 2020 2kWp6kWp + REZERVA 6kWp
36m2 = 6kWp OHEV TV + PROVOZ DOMU V OSTROVNM REIMU + VYUIT PEBYTK
PRO ELEKTROMOBIL 36m2 = 6kWp REZERVA NE PECHOD DO ZCELA NEZVISLHO
REIMU
54. 58 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 DNES
JI INSTALOVAN VKON 2 kWp NA OHEV TEPL UITKOV VODY 2014 Dnes ji
instalovny 2kWp s anc pidat podle vvoje
55. 59JIHOZPAD
56. 60 www.abatelier.czROZKLAD NA VODK NEBO NOV TYPY BATERI
Technologie odstartovaly zvod, kdo dve a lpe umon ukldat el.energii
v ase a s nejlep innost, ten bude zkladem dom tm nulovch.
57. 61 EPBD 2 Tm nulov dm CZ 2013 Plusov nezvisl dm 1984 ektro-
spotebie VZT Ohev TUV Vytpn Pasivn dm - 90% do15kWh/(m2a) Tm nulov
Dm EU Nulov dm ARCHITEKTURA M POTENCIL SPOR 80-90% A CO CHYTRHO DL?
ohev UV+ vytpn z OZE 0 50 100 150 200 250 Zstavba 20.stolet
celkovenergie[kWh/m2a] - 80% 180-240kWh/(m2a) Nzkoenergetick dm
do50kWh/(m2a) Zstavba 19.stolet SN 730540 2011 do90kWh/(m2a)
cca15-50kWh/(m2a) cca35kWh/(m2a) K NAPLOVN CL SMRNICE EU EPBD2 JE
ZAVEDEN POJEM TM NULOV DM KONCEPT PASIVNHO DOMU + ZAJITN OZE V MST
Jde o realitu nebo utopii? PD je vyzkouen koncept realizacemi a
vhodn pro vechny typy budov nejen pro bydlen a RD! Optimalizovan
TEAMOV nvrh OVEN V PHPP nezvyuje nklady na realizaci! PESTO Tm
nulov dm CZ 2013 ME BT JEN LEP NZKOENERGETICK DM RACIONLN EENM BY
MLA BT SNAHA REALIZACE PD NA CO NEJEFEKTIVNJ ROVNI!
59. 63 ASIVN (dle PHPP 13,7 kWh/(m2a) INDIVIDULN DEVOSTAVBA -
2012 NAHRADIT OHEV UV PANELY TEPLOVODNMI ZA OHEV PES FOTOVOLTAIKU =
2kWp JE VHODN ZA NI CENU JI DNES SROVNATELN TEPLOVODN SYSTM NA OHEV
UV cca s mont 110110 tis.tis. nkl. materil 8585 tistis FT PANELY S
VKONEM 2KwP cca s mont 9595 tis.tis. nkl. materil 7575 tistis
zdroj. Ing.Pavel Min PTIMALIZACE ZSOBOVN EL. ENERGI Z OZE - leden
2013
60. 64 N RD (dle PHPP 13,7 kWh/(m2a) INDIVIDULN DEVOSTAVBA -
2012 ZDE BUDE VHODNJ POUT STEN KRYTINU S INTEGROVANOU FOTOVOLTAIKOU
7PS = 2kWp 21 PS = 6kWp S MNIEM A AKUMULAC ME CELORON ZAJISTIT
ZKLADN PROVOZ DOMU, NA JAE A NA PODZIM I POTEBU UITKOV VODY A
VECHNY DAL PEBYTKY LZE VYUT PRO ELEKTROMOBIL Vize k realizaci po
roce 2016 v perodu po dokonen studii na TM NULOV DM - 2013
61. 6565 TM PASIVN RD dle PHPP 21 kWh/(m2a)
62. 66 TM PASIVN RD dle PHPP 21 kWh/(m2a)
63. 67 ENERGETICKY PASIVN BYTOV VILA POD ALTNEM VSLEDN
PARAMETRY DOMU DKY OPTIMALIZACI www. ABATELIER Ale Brotnek, Jan
Praisler nadmosk vka: 225 m n. m. PRAHA10, Stranice mrn poteba
tepla na vytpn dle PHPP: 14,714,7 kWh/(m2 a) mrn poteba tepla na
vytpn dle TNI 730329: 14,0 kWh/(m2 a) Uitn plocha dle PHPP: 591,6
m2 Uitn plocha dle TNI : 621,5 m2 obestavn vytpn prostor : 2427 m3
blower door test: 0,38 0,50,38 0,5 h-1 meno po bytech faktor A/V:
0,40,4 stna: U= 0,117 W/( m2 K) stecha: U= 0,092 W/( m2 K) podlaha
nad suternem: U= 0,146 W/( m2 K) okna: rm devo 88 PF = 1,14 W/( m2
K) Ug = 0,6W/( m2 K), g = 62 % obdob projektovn: 2009 2011 (28 msc)
obdob realizace: 2011 - 2012 (12 msc) vytpn/ temperovn: slavmi
panely s integrovanou vystkou vzduchu a hladk raditory v obvacch
pokojch vtrn: decentrln systm vtrn zen idlem CO2 zdroj: minimln
kondenzan plynov kotel Cena K/m3 z celkovho obestavnho prostoru,
bez DPH): 6500,-6500,- AUTOR: ABATELIER Ale Brotnek, Jan Praisler
INVESTOR: DEVELOPER JRD s.r.o.
64. 68 ENERGETICKY PASIVN BYTOV VILA POD ALTNEM decentrln VZT
jednotka v podhledu umstn v komoe otopn tleso s integrovanm pvodem
vtracho vzduchu idla pohybu a CO2 mal otopn tlesa nemus bt pod okny
Vysok kvalita vnitnho prosted s minimem technologi, jednoduch
ovladatelnost jednoduch ovladatelnost
65. 69 ENERGETICKY PASIVN BYTOV VILA POD ALTNEM technick
mstnost : mal plynov kotel + zsobnk TV technick mstnost : mal
plynov kotel + rozdlova a sbra PASIVN DM PIPRAVEN VYMNIT KOTEL ZA
PALIVOV LNEK
66. 70 ENERGETICKY PASIVN BYTOV VILA POD ALTNEM technick
mstnost : mal plynov kotel + zsobnk TV technick mstnost : mal
plynov kotel + rozdlova a sbra PASIVN DM PIPRAVEN VYMNIT KOTEL ZA
PALIVOV LNEK
67. 71 RD dle PHPP - 9 kWh/(m2a) S PPRAVOU NA NEZVISL PROVOZ
DOMU pprava na aktivn FV obklad celho 2.NP
2014www.abatelier.cz
68. 72 RD dle PHPP - 9 kWh/(m2a) S PPRAVOU NA NEZVISL PROVOZ
DOMU pprava na aktivn FV obklad celho 2.NP
2014www.abatelier.cz
69. 73 N RD dle PHPP - 9 kWh/(m2a) S PPRAVOU NA NEZVISL PROVOZ
DOMU vbr barevnosti aktivnho FV obkladu celho 2.NP
2014www.abatelier.cz Slunce kter v zim slou a v lt nekod
70. 74 le PHPP - 9 kWh/(m2a) S PPRAVOU NA NEZVISL PROVOZ DOMU
vbr barevnosti aktivnho FV obkladu celho 2.NP 2014www.abatelier.cz
Zdroj: SOLARTEC
71. 75 Solrn lnky s barevnm vzhledem Zkladn barevn kla jedna
vrstva 50 100 150 190 nm Procesy - CVD, PVD Souasn innost S
........ 18,5% Ped nkolika lety pouze8% monokrystalick kemkov solrn
lnky matn texturovan povrch tmav modr vzhled REDUKN FAKTOR BARVY
Tmav modr (75nm) .0,93 Svtle modr (110nm).....0,87 Hnd (50nm)
..........0,86 Zelen (240nm) ...0,79 Zlat (155nm) ...........0,78
Fialov (190nm)...........0,77 Stbrn (30nm)..0,73
72. 76 RD dle PHPP (6) kWh/(m2a) REDUKOVAN ZASTNNM ZELEN NA 9
kWh/(m2a) AVOU NA NEZVISL PROVOZ DOMU mon pprava na aktivn FV
stenho plt 2014
73. 77 Zdroj: SOLARTEC, R. Bainka 184 229 319 4 49 139 PASIVN
RD dle PHPP (6) kWh/(m2a) REDUKOVAN ZASTNNM ZELEN NA 9 kWh/(m2a)
2014 ORIENTACE SITUACE KE SVTOVM STRANM
74. 78 plocha jm.vkon prm. ron vroba prm. PR ron suma spec.
energie m 2 Wp kWh % kWh/kWp J 184 34,60 5 017 3 509 79,0 699,4 JZ
229 18,00 2 610 1 620 78,2 620,7 JV 139 18,00 2 610 1 772 79,2
678,9 S 4 21,40 3 103 699 69,3 225,3 SZ 319 49,50 7 178 2 102 72,1
292,9 SV 49 48,50 7 033 2 352 73,7 334,4 CELKEM 190,00 27 550 12
054 orientace PASIVN RD dle PHPP (6) kWh/(m2a) REDUKOVAN ZASTNNM
ZELEN NA 9 kWh/(m2a) 2014 Vkon a mnostv vyroben energie
75. 81 MODEL PRODNHO A PASIVNHO RD dle PHPP 15 kWh/(m2a),
76. 82 MODEL PRODNHO A PASIVNHO RD dle PHPP 15 kWh/(m2a),
77. 83 MODEL PRODNHO A PASIVNHO RD dle PHPP 15 kWh/(m2a), Datov
kamna - nov zpsob vytpn pomoc vkonnch server
78. 84 www.abatelier.cz ROPN ZLOM (peak oil) ANCE K VYUIT
NABDKY NEBO OHROEN? Zdroj: Zda si zvolme pozitivn nebo negativn scn
je pouze na ns 1984 NYN JSME ZDE S ROZVOJEM TECHNOLOGI ZA POMOCI
FOSILI PEAK OIL DVE SVAZUJC LIMIT ZTRA ANCE ZAJISTIT KOMFORT POMOC
OZEOZE NROKY 21.st. + OPTIMALIZOVAN PD + CHYTR TECHNOLOGIE ANCE
PROPOJIT
79. 85 www.abatelier.cz Zdroj: Pozitivn scn efektivnj vyuit
energie a zapojen OZE ji 2016? Zkladn bukou CHYTR ST je bytov
jednotka nebo RD v pasivnm standardu z 90-120% zajiujc i el
energii. Rozvoj dopravy ELEKTRO MOBILITOU umon flexibiln akumultory
s dobjenm bhem 10-15 minut (netoxick, 1/3 vhy, trojnsobn kapacita-
ji ve vrob s masovm rozenm ) s aknm rdiusem 300- 600 km dle
zte.(TESLA-spojen Americ a Dnsk technologie) Budovy poskytuj ZDRAV
KOMFORT, na 100 % funkn i po BLACKOUTU pechodem do OSTROVNHO SYSTMU
odpojenm zbytnch funkc a prunou kooperac s ELEKTROMOBILITOU OZE
poskytuj nezvislost MIXEM ZDROJ (vodn, vtrn, fotovoltaick, bioplyn,
biomasa) a voln kapacita elektrobateri vetn elektromobil,
peerpvacch ndr, bioplynovch genertor, vodkovch akumultor atp. je
vyuvna v rmci nadazenho ostrovnho systmu CHYTRCH ST 1984 CHYTR
ENERGIE, OZE, ST, DM, ELEKTROMOBIL = CHYTR ROPN ZLOM CHYTR S
INTELIGENTN ST (SMART GRIDS) JSOU SILOV ELEKTRICK A KOMUNIKAN ST,
KTER UMOUJ REGULOVAT VROBU A SPOTEBU ELEKTRICK ENERGIE V RELNM
ASE
80. 86 www.abatelier.cz Ale Brotnek ASOV PLN REALIZACE SMRNICE
EPBD2
81. 87 2013 2014 ZKUENOSTI A PRAKTICK UKZKY Z REALIZAC PASIVNCH
A TM NULOVCH DOM www.abatelier.cz Ale Brotnek 2012 CESTY K NEZVISL
ARCHITEKTUE.
82. 88 ZKUENOSTI A PRAKTICK UKZKY Z REALIZAC PASIVNCH A TM
NULOVCH DOM www.abatelier.cz Ale Brotnek DKUJI ZA POZORNOST!
83. 89
84. 90
85. 91
86. 92
87. 93
88. 94
89. 95
90. 96
91. 97
92. 98 VYUIT BALK ZE SLMY KE STAVB PILO Z NEBRASKY V USA - -
SLMA JAKO NOSN PRVEK Ale Brotnek
93. 99 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
94. 100 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
95. 101 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
96. 102 Prvn kurzy stavn ze slmy - Libeves 1996-99 EXPERIMENTLN
KOLEKTIVN VESTAVBA VE STODOLE VIDOVICCH NAD MLNIC
97. 103 TEHOV - 2005-06 STAVT PED KONSTRUKCI, KTER ZSTV
VIDITELN V INTERIERU Ale Brotnek
98. 104 DM STROM PROJEKT 2009-11 AUTOI:J.SMOLA,
A.BROTNEK,J.PRAISLER VKLDN IZOLACE Z BALK MEZI INOSNKY V OBVODOVM
PLTI
99. 105 HRADANYU TINOVA II. 2006-10 AUTOI: A.BROTNEK,J.PRAISLER
PROLNN IZOLACE Z BALK S NEHRANNOU KULATINOU KONSTRUKCE
100. 106 M PASIVN PZEMN DEVOSTAVBA SE SLMOU A HLNOU - 2011 mrn
poteba tepla na vytpn dle PHPP: 18-2318-23 kWh/(m2 a) 2kWp