A B C D F
A B C D F
01 01
02 02
03 03
2a
04
05
0606
05
E
04
Da
10 x 16,17/30
13 x 16,17/30
22 x1
6,6/
28
Pav02
Pav04
Pav05
Pav07
Pav07
D-Pav03-A
D-Pav07
D-Pav09-B
Pav09
D-Pav09-A
Pav10
m²11.4
m²11.3
Pav07 m²4.9
m²49.7 m²38.7 m²49.7
m²64.0m²143.0
m²298.3
m²48.8
m²21.4
m²21.4
m²49.1 m²21.5
Pav04
Pav04
Pav04 Pav04
Pav04 Pav04 Pav04
Pav04
A B C D F
A B C D F
01 01
02 02
03 03
2a
04
05
0606
05
E
04
Da
10 x 16,17/30
22 x
16,6
/90
ALLACCIAMENTO ACQUE MISTE(vedi tavola H.PE.618)
diverso
Pav06
D-Pav01-AD-Pav03-A
Pav06
Pav06
Pav05
Pav08
Pav08
Pav08
m²9.0
m²21.4
m²3.9
m²384.2
m²33.3
m²8.06
m²44.0
m²11.3
m²10.9
m²4.8m²49.7 m²42.6
m²30.0
m²38.6
m²9.2
Pav08 m²6.8
Pav08
m²8.9Pav06
m²4.7
Pav01
Pav03
Pav03
Pav03
Pav03
Pav03
Pav03 Pav03
PAVIMENTAZIONE INTERNA - Pav035mm: pavimento in linoleum (colore e finitura a scelta DL)6cm: massetto galleggiante- strato separatore foglio PE2,5cm: isolamento anticalpestio doppio strato (5+20mm)10cm: isolamento termico in pannelli XPS8,5cm: massetto alleggerito4mm: barriera al vapore /guaina bituminosa5cm: cappa in c.a.40cm: vespaio areato con sistema a igloo10cm: magrone in cls
tessuto non tessutoterreno
LI
IP
0,5
2,5
108,
55
4010
+0,15
-0,18
-0,58
6
-1,08
5010
Battiscopa inlegno di roveremassiccio
5310
8
27,5
PAVIMENTAZIONE INTERNA - Pav015mm: pavimento in linoleum (colore e finitura a scelta DL)6cm: massetto galleggiante con pavimento radiante- strato separatore foglio PE2,5cm: isolamento anticalpestio doppio strato (5+20mm)10cm: isolamento termico in pannelli XPS8,5cm: massetto alleggerito4mm: barriera al vapore /guaina bituminosa5cm: cappa in c.a.40cm: vespaio areato con sistema a igloo10cm: magrone in cls
tessuto non tessutoterreno
LI
0,5 +0,15
62,
510
8,5
540
10
IP
-0,18
-0,58
1,5 30 1,5
5010
-1,08
Battiscopa inlegno di rovere
massiccio
8
27,5
53
30
+3.87
+3.62
PAVIMENTAZIONE INTERNA - Pav071cm: piastrelle in gres porcellanato (colore e formato a scelta DL)6cm: massetto galleggiante- strato separatore foglio PE2,5cm: isolamento anticalpestio doppio strato (5+20mm)15cm: massetto alleggerito- solaio in cemento armato secondo strutturale
16
2,5
15
PG
30120,5
PG
2
24,5
0,7
PAVIMENTAZIONE INTERNA - Pav055mm: pavimento pedata in linoleum
(colore e finitura a scelta DL)5cm: malta- scala in cemento armato
secondo elaborato A.PE.
5mm: finitura alzata in linoleum(colore e finitura a scelta DL)
3cm: malta
0,5
5
0,5 3
+1,93
LI
+1,88
0,5
515
+173
16,2
30
LI
1,4%
1,5 7,5 2 11 2 7,5 1,5
30va
r.va
r.
+3.87
+3.62
PFC
+3.32
PFL
PAVIMENTAZIONE ESTERNA - Pav096cm: sistema di pavimento sopraelevato con piastre in ghiaino lavato
piedini distanziatori con guarnizione di appoggio a protezione della guaina
- guaina impermeabile10/18cm pannelli pendenzati di isolamento in poliuretano4mm: guaina bituminosa / barriera al vapore30cm: solaio in cemento armato secondo strutturale
6
30
Raccordo a flange con la guaina impermeabileTubo pluviale INOX Ø110
IPIP
CG
24,5
PFC
IE
+3.87
+3.62
+3.32
PAVIMENTAZIONE ESTERNA - Pav096cm: sistema di pavimento sopraelevato con piastre in ghiaino lavato- piedini distanziatori con guarnizione di appoggio a protezionedella guaina- guaina impermeabile10/18cm pannelli pendenzati di isolamento in poliuretano4mm: guaina bituminosa / barriera al vapore30cm: solaio in cemento armato secondo strutturale16cm: isolamento a cappotto in polistirene espanso
tasselli annegati con rondelle di chiusura in polistirene espanso finitura con intonaco strutturato (vedi prospetti)
630
var.
var.
0,7
160,
5
12 0,7 30 0,7 12 0,5
IE
24,5
Linoleum
LN-2
Linoleum - scale
LN-S
Linoleum
LN-1
PG-1
Piastrella in gres
Pav02
Pav04
Pav07
Pav05
Pav01
Pav03
Pav06
PG-2
PFC
Piastrella in gres
Pavimento flottante in ghiaino lavato
PG-S
Piastrelle in gres per esterni - scala
Pav09
Pav08
Pav10
Battiscopa in legno di rovere massiccio 10x80 mm
Progetto
Committente
PROGETTO ESECUTIVO - PROGETTO ARCHITETTONICO
Servizio Urbanistica, ambiente, assetto del territorio lavori pubblici, via Fiori dei Liberi n.23 - 33040 Premariacco (UD)tel. 0432/729009 | e-mail: [email protected]
Comune di PremariaccoProvincia di Udine
Responsabile del procedimento: Geom. Marco Toti
33040 Premariacco
Via Fiore dei Liberi n.23
tel. 0432/729009 | fax 0432/729072
Contenuto
Via della Chiesa n.32 - 33040 Premariacco
Lavori di ristrutturazione, ampliamento eadeguamento alle norme di sicurezza
della scuola elementare di Premariacco
CUP: E16J16000690006
Tecnico
Dr. Arch. Matteo ScagnolMoDus architects
Progettista architettonico
39042 BressanoneFallmerayerstraße, 7tel./fax. 0472/[email protected]
FirmaFirma
Regione Autonoma Friuli Venezia Giulia - Provincia di UdineCOMUNE DI PREMARIACCO
A
Responsabile del procedimentoGeom. Marco Toti
Elaborato Nr. Progetto Data Scala Indice Modifica
0215 26.05.2017 - -
Tavola n. / File n.
Dr. Arch. Matteo ScagnolMoDus architects
39042 Bressanone (BZ)Via Fallmerayer 7tel./fax. 0472/[email protected]
PARCIANELLO & PARTNERSengineering srl
32016 Farra D'Alpago (BL)Via G. Matteotti 30/dtel./fax. 0437 46100 / 0437 [email protected]
Cooprogettisocietá cooperativa
06024 Gubbio (PG)Via della Piaggiola 152tel./fax. 075 923011 / 075 [email protected]
dr. for. Alessandro Rocco
32100 BellunoVia E. De Amicis 209tel. 0437 [email protected]
Raggruppamento temporaneo di professionisti
file:
P:\0
215
Prem
aria
cco(
UD)\1
2 PE
\DW
G\A.
PE.1
10-1
19 P
AVIM
ENTI
E S
OFFI
TTI\0
215
A.PE
.110
-119
PAV
IMEN
TI S
OFFI
TTI.d
wg25
.05.
2017
PAVIMENTI Piano Terra, Piano Primo
MP
A.PE.110
1:100 - 1:10 -
LEGENDA IMPIANTI TECNICI
LEGENDA SIMBOLI
FORO SOLAIO SOTTOSTANTE Lu/La - FSI
FORO PARETE Lu/A - FP
SCANALATURA A PARETE Lu/La - SPNICCHIA NELLA PARETE Lu/La/A - NP
FSI 120x20
SP 100x20x40/SP 40x20QI=Pav.Fin. +80
ESTINTORE - NASPO A MURO
FSS 120x20
FP 120x20
FORO SOLAIO SOPRASTANTE Lu/La - FSS
IMPIANTO TERMOIDRAULICO
CANALETTA
LEGENDA PORTE LEGENDA FINESTRA
LEGENDA PARETI SOLAI
NUOVO CEMENTO ARMATO
SALTO DI QUOTA NEL SOLAIO GREZZO
-0,2
7
-1,0
2
-1,3
0
-0,5
5
IMPIANTO ANTINCENDIO
RADIATORE
FORO FONDAZIONI Lu/La - FFPOZZETTO A PAVIMENTO Lu/La - PP
Ø 10PLUVIALE Ø cm
E
PULSANTE D'ALLARME
ESISTENTE STRUTTURA PORTANTE
NUOVA STRUTTURA PORTANTE
NUOVO MURATURA IN MATTONI
C.A. FACCIAVISTA CLASSE III
PIASTRELLE IN CERAMICAPIASTRELLE IN GRES
LINOLEUM
POLIURETANO
PCPG
LI
PUR
GRIGLIA
VETRO CELLULARE
POLISTIRENE ESTRUSOLANA DI ROCCIA
GR
SG
XPS
LR
MATERIALE
RESINA RPAVIMENTO INDUSTRIALE PINDPOLISTIRENE ESTRUSO EPS
LASTRE IN PIETRA NATURALE PT
GOMMA GM
TAVOLATO IN LEGNO TL
LASTRE DI CALCESTRUZZO BP
PAV. FLOTTANTE IN GHIAINO LAVATO
PAVIMENTO IN LEGNO L
TETTO VERDE TV
PFC
IMPIANTO ELETTRICO
PROGETTO STATICO
APPALTO ARREDO
QUOTA PAVIMENTO FINITO
QUOTA SUPERIORE SOLAIO GREZZO
+0,00- 0,19
QUOTA INFERIORE SOLAIO FINITO
+0,45
+0,20 QUOTA SUPERIORE SOLAIO GREZZO
QUOTA INFERIORE SOLAIO GREZZO +3,98
LEGENDA FORI LEGENDA QUOTE
QUOTA INFERIORE TRAVE DA PAVIMENTO FINITO hTHPHN
QUOTA PARAPETTO DA PAVIMENTO FINITO
ALTEZZA NETTA AMBIENTE DA PAVIMENTO FINITO
LEGENDA RIFERIMENTI
IP
LEGENDA TABELLE
m²scalaSC.01 18,5
24 12,5 / 30H
CODICE: Livello. Nr. ambiente
NOME AMBIENTE
AREAPERIMETRO
QUOTA PAV. FINITOQUOTA SOLAIO GREZZO
AREA
ALZATA / PEDATA FINITO
DIMENSIONI VANO
NUMERO PERSONEPORTATA
ascensore
KG
A.02 120 x 220
121,000
13
A
B
C
DALTEZZE: Altez. netta
CODICE: Ascensore. Numero
CODICE ASCENSORE
CODICE AMBIENTE
FINITURE SUPERF.: pavimento - solaio
CODICE SCALA
PAVIMENTAZIONENr. ALZATE
CODICE: Scala. Numero
B-D-BA-018
CODICE SVILUPPO AMBIENTI
CODICE DETTAGLIO
VEDI DETTAGLIO NR.
INDICAZIONE FINITURA
es. INTONACO PITTURATO
QUOTA SUPERIORE PAVIMENTO FINITO
+0,45
MASSETTO LEVIGATO ML
ZERBINO INCASSATO Z
SISTEMA DI ISOL. A CAPPOTTO WDVS
CARTONGESSO
CEM. ARMATO A VISTA CON CLASSE
INTONACO PITTURATO
CARTONGESSO
PANNELLO IN LEGNO
INTONACO PITTURATO LAVABILE
PANNELLO FONOASSORBENTE IN FIBRE DI LEGNO
CEM. ARMATO A VISTA PITTURATO
CARTONGES. FORATO FONOASSORBENTE
INTONACO ESTERNO
INTONACO ACUSTICO A SPRUZZO
METALLO
PANNELLI IN GESSOFIBRA
PITTURA
MTSB I-II-III
IPL
SBA
IP
P
IA
CGCA
IE
PFL
GFPL
SILICATO DI CALCIO KS
PROTEZIONE SOLARE MANUALEPROTEZIONE SOLARE ELETTRICA
T02
80 220
EL-P-ETO-EI 60
SHPH
PSPSE
PROTEZIONE OSCURANTE ELETTRICA POE
SERRATURA S
FINESTRA TIPO F10CORNICE TIPO B1
PSE CON 2 MOTORI PSE(2)
AELFINESTRA AUTOMATICA
MKCONTATTO MAGNETICO ANTINTRUS.
MANIGLIA ANTIPANICO P
EVACUAZIONE FUMI RA
2,35
1,80 LUCE GREZZA
ALT. GREZZA(da pav. finito)
EL
PMANIGLIONE ANTIPANICO
APRIPORTA ELETTRICO
OTSCHIUDIPORTA IN ALTOBTSCHIUDIPORTA A PAVIMENTO
EI 60RESISTENZA AL FUOCO 60 MIN.MKCONTATTO MAGNETICO ANTIINTRUSIONEAELPORTA AUTOMATICA
ETOFERMA PORTA A CONTATTO ELETTR. SUPER.ETBFERMA PORTA A CONTATTO ELETTR. INFER.
TSCHIUDIPORTA A MOLLA
PORTA TIPO 02
LUCE NETTAALT. NETTA (da pav. finito)
EL P
OTS
BTS
MK
ETO
ETB
TS
ALTEZZA DELLA TRAVE (da quota superiore pav. finito)
ALTEZZA PARAPETTO (da quota superiore pav. finito)
CARATTERISTICHECARATTERISTICHE
+2,80+0,60
POE
PSE-S
F10
B1
Tutte le misure sono da controllare e da verificare in cantiere da parte della ditta appaltatrice, che è responsabile della loro esattezza.Tutti i disegni esecutivi architettonici sono da considerarsi sempre insieme agli elaborati esecutivi dei tecnici incaricati. Le indicazioni rispetto a particolari dettagli sono da prendere in considerazione. Eventuali discrepanze con ilprogetto vanno comunicate alla D.L. prima dell'inizio dei lavori. Tutte le indicazioni per fori e scanalature vanno verificate prima dell'esecuzione da parte dell'impresa appaltratrice. Tutte le misure di nuova costruzione si riferiscono, ovenon diversamente specificato, al grezzo senza intonacatura o rivestimento. Le misure delle costruzioni esistenti sono misure dello stato di fatto, sono tutte da verificare in cantiere e possono variare dalle misure indicate nelle tavole diprogetto. Le altezze delle porte sono indicate dal pavimento finito al grezzo dell'architrave. Le altezze dei parapetti sono indicate dal pavimento finito al grezzo del parapetto. Tutte le scatole e i tubi da inserire prima del getto in clssono da eseguire esattamente come indicato nel progetto elettrico e dell'impiantista.
NUOVO C.A. IMPERMEABILE
H
m² mVANO TECNICO
-01.08
2,60 -3,60
-3,90DB PA
18,0063,00
LEGENDA ISOLAMENTI
FIBRA DI LEGNO - LANA MINERALE
EPS - POLISTIROLO ESPANSO
SG - VETRO CELLULARE
XPS - POLISTIROLO ESTRUSO
PIR - POLYSO
SIRENA
LAMIERA METALLICA FORATA LMF
GHIAIA LAVATA GLCEMENTO SPAZZOLATO CS
INDICE DATA ELAB. MODIFICA
Pianta piano primo
PAVIMENTI
Pianta piano terra
PAVIMENTI
DETTAGLIO Pav07
1:10
DETTAGLIO Pav06
1:10
DETTAGLIO Pav01
1:10
DETTAGLIO Pav03
1:10
DETTAGLIO Pav09 - B
1:10
DETTAGLIO Pav09 - A
1:10
LEGENDA PAVIMENTI