Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
CAPITOL Veranstaltungs- und Gastronomie GmbH
Venue:Schwarzer Bär 2
30449 Hanover
Management: Ferdinand-Wilhelm-Fricke-Weg 8
30169 Hannover
Phone +49 (0) 511 / 929 88 - 0
Fax +49 (0) 511 / 929 88 - 49
www.capitol-hannover.de
Welcome! ...................................................... 03
Photos ................................................... 04 / 05
Layout ground floor ............................................ 06
Layout 1st and 2nd floors ...................................... 07
Horizontal plan views ........................................ 08
Top view stage ................................................ 09
Hall data ..................................................... 10
............... stneve trecnoc evil rof thgiL & dnuoS tnempiuqE 11
Equipment Sound & Light for Disco events ...................... 12
............................................... metsyS gnithgiL 13
.................................................... snoitceriD 14
Inhalt
page 2
The CAPITOL red-brick high-rise building was erected in the 20’s of the
last century and has become a well known iconic landmark of the City
of Hanover. The listed building is situated by the banks of the river
Ihme in the heart of Hanover, beautifully visible from afar.
Until 1986 CAPITOL was a cinema theatre, but nowadays it has become
a spacious event location, offering the appropriate facilities for
your concepts: from concerts with national or international stars, for
theme parties or Abitur finals’ celebration, student’s parties as well as
elaborate customer events and incentives – anything is possible!
The premises of CAPITOL have a unique charm that emanates a very
intimate atmosphere. As the space spreading over 2 floors with several
rooms is variable, CAPITOL is the perfect venue for events of any size,
from 400 to 1.600 guests – offering the latest equipment for sound
video and lighting and a fully equipped stage: simply the right choice
for your event!
Optionally we can organise and plan your complete event including
artist performance, customized decoration to suit your event and first
class catering according to your specifications.
We organise the accommodation for your guests, service staff, technical
equipment and security. Are you looking to leave a lasting impression
and memorable on your guests? CAPITOL is the perfect location for you!
We look forward to meeting you in person and are at your disposition to
discuss your requirements.
The CAPITOL Team
Welcome! References
page 3
page 4
page 5
1 Entrance
2 Ticket office
3 Foyer
4 Bar
5 Merchandising
6 Cloakroom
7 Platform
8 Main hall
9 Platform for the disabled
10 Delivery entrance
11 Ramp
12 Stage
13 Electronic equipment room
14 Storage
15 Arcades
1
2 3
4
5
4
4
4
67
7
8
9
12
13
11
1015
14
Loading area
Layout Ground floor
M 1:300
page 6
Layout 1st floor / 2nd floor
1311a 11b
8
8
99
13
1011
12
2
1
1
1
12
6 7
5
3
4
1 Bar
2 Projectors
3 Balcony
4 Level 2
5 Level 1
6 Main hall
7 Stage
8 Office / production
9 Artist’s dressing rooms
10 Kitchen
11 Bath & WC
a Gentlemen
b Ladies
12 Catering
13 Smoker’s lounge
First floor(1. OG)
Second floor(2. OG)
98
M 1:300
1
page 7
Horizontalviews
12
11
12
13
1110
9
4321
56
78
1 Entrance
2 Foyer
3 Platforms
4 Main hall
5 Projectors
6 Level 2
7 Balcony
8 Level 1
9 Gallery
10 Stage pit
11 Stage
12 Internal PA system
13 Gallery DJ / LJ
M 1:3005 m
M 1:2005 m
Horizontal view bb`
Horizotal view aa`
page 8
Top View Stage
Light or sound 2 x 125 A CEE, 3-phase power
1 x 32 A CEE, 3-phase power
1 x 16 A CEE, 3-phase power
1
2 3
4 45
9
8
6 8
7
3
1114
1210
Power connection 10
13
15
16
17
1 Main hall
2 Storage
3 Disco and light system
4 Internal PA system
5 Screen
6 Stage pit
7 Barriers
8 Premises’ lights
9 Stage
10 Power connection
11 Stage side room
12 Stage anteroom
13 Exit stage
14 Ramp
15 Delivery entrance
16 Artist’s WC
17 Arcade passage
M 1:300
page 9
Hall data
Contact person
Managing Director Michael Lohmann / Nico Röger
Booking Melanie Stockem-Schroeder
Tel.: +49 (0) 511/929 88 - 13
Phone +49 (0) 511 / 929 88 - 0
Fax +49 (0) 511 / 929 88 - 49
Technical manager Detlef Schumann Tel.: +49 (0) 151 / 46 10 94 36
Capacity without seating 1.600
Visibility obstructions no
Special features Balcony without seating: 700
Dance floor without seating 900
Partial seating 400 seats incl. bar stools
700 standing space
Platform for wheelchairs yes, stage left
Low emission zone
Because CAPITOL is located in the centre of town, it is also within the low emissi-on zone (UMWELTZONE), and therefore since 1st January 2008 you can only drive to our doorstep only if your car has been awarded the green environmental badge (Umweltpla-kette), which is available from the car registration office, TÜV, DEKRA or certified garages. Further information to UMWELTZONE, please see www.hannover.de (Umweltzone).
Stage
Hall type Club
Stage system fixed
Stage width 10,5 m front edge / 7,40 m centre /
9,00 m back edge
Stage depth 8,00 m
Stage hight 1,56 m
PA-Wings not available
PA hanging
Lights hight front 9,00 m / centre 5,00 m / back 6,00 m
Barrier fixed safety grids at front of stage
Loading path 10,00 m
Forklift truck no
CAPITOL Veranstaltungs- und Gastronomie GmbH
Venue:Schwarzer Bär 230449 Hannover
Management:Ferdinand-Wilhelm-Fricke-Weg 830169 Hannover
Phone +49 (0) 511 / 929 88 - 0Fax +49 (0) 511 / 929 88 - 49
Power connection
Power #1 2 x 3 x 125 Amp stage right CEE
Power #2 1 x 3 x 32 Amp. stage right CEE
Power #3 1 x 3 x 16 Amp. stage right CEE
Spotlights chasers positioned on the balcony
In-house sound system on stage, no side wings available
Suspension points (light) front 2 points ea. 500 kg back 4 points ea. 400 kg
Suspension specifications for events with a follow-up disco only 4 suspen-sion points available
Cable routing hanging from ceiling
Backstage area
Catering room Corridor in front of cloakroom
Gas connection no
Cloakrooms 3 cloakrooms, 2 production offices / 3 showers
Extras Washing machine, clothes dryer, ice cube maker
Miscellaneous
Production communication charges per unit 0,15 €, telephone lines, fax lines without devises, DSL / W-LAN
FOH - Mixer - Position by agreement
Parking Limited parking available for 2 long vehicles (1 truck + 1 nightliner or 2 nightliners).Nightliner must be parked first and backwards. Truck must be parked forward and loading in direction to the bridge.
Power connection Power Nightliner: 32 A CEE, 16 A CEE,16 A Cekon blau, 16 A Schuko
Merchandise limited by the defined area, 110 €
Sound volume limit 99 dba
Sound check from 4 p.m.
page 10
for live concert events
Equipment Sound & Light
CAPITOL Veranstaltungs- und Gastronomie GmbH
Venue:Schwarzer Bär 230449 Hannover
Management:Ferdinand-Wilhelm-Fricke-Weg 830169 Hannover
Phone +49 (0) 511 / 929 88 - 0Fax +49 (0) 511 / 929 88 - 49
FOH
Yamaha PM5D 48ch
Playbacks
1x Multicore analog with Monitor-Split, 48x Send/ 8x Return
1x Sony CD P-297
2x Cat 5 e from FOH to Stage
1x Tecpro MS 731 Intercom Station, 1x Beltpack, 2x Headset
Mic‘s and DJ´s
2x Beyerdynamic M 201 N C
1x Shure Beta 52A
4x Shure Beta 56A
1x Shure Beta 58A
1x Shure Beta 87A
1x Shure Beta 91A
6x Shure SM 57
5x Shure SM 58
3x Shure SM 81
1x Sennheiser e905
3x Sennheiser e908 D
PA
12x Kling & Freitag Sequenza 10N
6x Kling & Freitag Sequenza 10W
6x Kling & Freitag Systemrack
4x Kling & Freitag Sequenza 10B
(Lab.grupen FP 10000Q, CD-44 )
6x Kling & Freitag Nomos XLC
2x Kling & Freitag CA 1215-6 (Nearfill)
2x Kling & Freitag CA 1001–SP (Delay under balcony)
2x Kling & Freitag CA 1515-6-SP (Delay on balcony)
2x Kling & Freitag HK VT-112 (Delay Smoker)
2x Kling & Freitag HK VT-112 (Delay anteroom)
Audio-, video-, DVD-equipment
electric projection screen 10x8 m, front projection,permanent installation, downstage edge
portable projection screen, front projection withstandard legs, formats: 4x3 m (4:3), 4x2,25 m (16:9)
hanging in the fronttruss
7x
1x Epson EB-1980WU, WUXGA resolution and 4400 Lumen,
TV monitors
Monitor
Yamaha M7cl 48ch
10x Kling & Freitag CA 1515-6 - SP
2x Kling & Freitag Line 212-6 – SP
2x Kling & Freitag SW 215E – SP
2
4x Sennheiser e 300 IEM G3 with receiver
x Kling & Freitag SW 115 – SP
2x Sennheiser e914
2x Sennheiser e945
1x Sennheiser MD609
2x Sennheiser SKM 2000 with capsules e 935 and e 965
2x Talkback-Microphone with switch
2x ACC DI-Four
4x Palmer PAN 02
3x IMG Stageline DIB 100
page 11
for Disco events
Balcony: 2x Kling & Freitag CA 1515
Dance floor balcony: 2x HK VT 112 1x CPA 15“ Bass Box
CAPITOL Veranstaltungs- und Gastronomie GmbH
Venue:Schwarzer Bär 230449 Hannover
Management:Ferdinand-Wilhelm-Fricke-Weg 8 30169 Hannover
Phone +49 (0) 511 / 929 88 - 0 Fax +49 (0) 511 / 929 88 - 49
page 12
Disco main console
16x Martin Roboscan 218 MKII
2x Martin Atomic 3000
2x Clay Paky Alpha Spot HPE 575
30x LED Par 56 RGB
1x mirror ball 75cm
diverse Par 16
CAPITOL balcony console
diverse Par 36
DJ Truss
8x LED Par 56 RGB
1x 4light Blinder
LJ Truss
8x LED Par 56 RGB
1x 4light Blinder
Light controls Disco
MA on PC Faderwing
2x 512 DMX-channels
Sound system Disco Kling & Freitag
PA same as live concert events
DJ Mixer: Pioneer DJM-900 NXS2, DJM-800CD Player: 2 x Pioneer CDJ-900 NXS, Denon DN-4500 MK2, Numark CDN 77Turntable: 2 x Technics 1210 MK2
12
16
7
5
300 300
300 300 300
400ATOMIC
3000
ATOMIC3000
Hazer
ACL ACL
ACLACL
ACL
ATOMIC3000
Hazer
6er-Bar CP88 (3)
6er-Bar CP60 (4) top mount
4er-Bar ACL (4) top mount
4-Lite DWE (4)
CP Alpha Spot HPE 300 (8)
GLP Impression 90 RGB (6)
Martin Atomic 3000 (2)
Look Unique 2.1 (1)
CP Alpha Wash 700 (4)
5x dimmer4x fix power
5x dimmer2x fix power
4x dimmer4x fix power
Floor:4x dimmer
up to 8 lines DMX to FOH
Lighting System
page 13
99
10
12
6
ATOMIC3000
ACL
ATOMIC3000
Hazer
6er-Bar CP88 (3)
6er-Bar CP60 (4) top mount
4er-Bar ACL (4) top mount
4-Lite DWE (4)
Varilite VL 3000 Spot (6)
GLP Impression 90 RGB (6)
Martin Atomic 3000 (2)
Look Unique 2.1 (1)
CP Alpha Wash 700 (4)
4x dimmer4x fix power
99
10
12
12
67
ATOMIC3000
ACL
ATOMIC3000
Hazer
6er-Bar CP88 (3)
6er-Bar CP60 (4) top mount
4er-Bar ACL (4) top mount
4-Lite DWE (4)
CP Alpha Spot HPE 300 (8)
Robe Robin 800 LedWash (6)
Martin Atomic 3000 (2)
Look Unique 2.1 (1)
CP Alpha Wash 700 (4)
4x dimmer4x fix power
discolight
epage 13
DirectionsBy public transport...
Tram• from Hanover main station (Hauptbahnhof) Tram No. 9 (towards Empelde)or Tram No. 17 (towards Wallensteinstraße) get off at Schwarzer Bär• or Tram No. 3 or 7 (towards Wettbergen) get off at Waterloo
Bus• from Aegi: Bus No.120 (towards Ahlem)• from Hanover main station (Hauptbahnhof): Bus No. 500 (towards Ronnenberg/Gehrden) or Bus No. 300(towards Pattensen) get off at Schwarzer Bär
By car...
arriving from the motorway A2 • exit the motorway at Hannover-Herrenhausen, onto the B6 (Westschnellweg)• follow the B6 towards Hannover Linden / Ihme-Zentrum, take the exit and• turn left into Fössestraße, and stay on it for about 800 m, then• turn right into Blumenauerstraße• turn left into the multi-storey car park of Ihmezentrum[further parking available in the car park at Humboldtstraße]
[further parking available in the car park at Humboldtstraße]
arriving from the motorway A7 • at the motorway crossing Kreuz Hannover Nord, take the A 352 or 354 towards Dortmund,• exit at Hannover-Herrenhausen onto B6 (Westschnellweg)• turn left into Fössestraße, and stay on it for about 800 m, then• turn right into Blumenauerstraße• turn left into the multi-storey car park of Ihmezentrum
arriving from Hanover Messe • take the Messeschnellweg towards Zentrum / Minden / Hameln• carry on straight ahead (do not take the exit Zentrum!), until you get to a roundabout• at the roundabout take the first exit to the right• carry on straight ahead until the next roundabout “Ricklinger Kreisel”• straight ahead over the roundabout, then carry on straight ahead towards Ihmezentrumon the left hand lane until the roundabout Deisterkreisel• in the roundabout Deisterkreisel take the first exit into Deisterstraße,• then carry on straight ahead, Deisterstraße ends at Schwarzer Bär• take the curve to the right now CAPITOL is on your left• at the next option make a U turn so that CAPITOL is on your right• drive past CAPITOL and turn right into Blumenauerstraße• turn right into the multi-storey car park of Ihmezentrum
CAPITOL Veranstaltungs- und Gastronomie GmbH
Venue:Schwarzer Bär 230449 Hannover
Management:Ferdinand-Wilhelm-Fricke-Weg 830169 Hannover
Phone +49 (0) 511 / 929 88 - 0Fax +49 (0) 511 / 929 88 - 49
Low emission zone
Because CAPITOL is located in the centre of town, it is also within the low emission zone (UMWELTZONE), and therefore since 1st January 2008 youcan only drive to our doorstep only if your car has been awarded the green environmental badge (Umweltplakette), which is available from the car registration office, TÜV, DEKRA or certified garages.
Further information to UMWELTZONE, please see www.hannover.de(Umweltzone).
page 14
[further parking available in the car park at Humboldtstraße]