Product Data Sheet 00813-0100-4690, Rev EA Catalog 2002 2003 Model 2088 www.rosemount.com A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS Absolute and gage pressure ranges from 010 psi to 04,000 psi (069 to 0276 bar) 0.20% reference accuracy, including linearity, hysteresis, and repeatability 20:1 turndown Lightweight, compact size makes for easy installation and handling 0.1% High accuracy option Content Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-173 Hazardous Locations Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-176 Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-177 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-179 Configuration Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-181 Model 2088 Absolute and Gage Pressure Transmitter

Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS� Absolute and gage pressure ranges from

0�10 psi to 0�4,000 psi (0�69 to 0�276 bar)

� 0.20% reference accuracy, including linearity, hysteresis, and repeatability

� 20:1 turndown

� Lightweight, compact size makes for easy installation and handling

� 0.1% High accuracy option

www.rosemount.com

ContentSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-173

Hazardous Locations Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-176

Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-177

Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-179

Configuration Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page Pressure-181

Model 2088 Absolute and Gage Pressure Transmitter

Page 2: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EA

Catalog 2002 � 2003Model 2088

The Model 2088

The Rosemount® Model 2088 Smart Pressure Transmitter is an economical addition to the Rosemount pressure transmitter line of instruments. The Model 2088 is designed with reliability, long-term performance, and maintainability in mind. Model 2088 transmitters maintain a specification conformance of at least 30�(1). The rugged, reliable performance for which Rosemount transmitters are famous-coupled with its smart capabilities-make these transmitters exceptional values.

The Model 2088 is available in either gauge or absolute pressure in pressure ranges to 4,000 psi (275 bar). It utilizes a solid-state, polysilicon pressure sensor with a choice of either 316L or Hastelloy isolating diaphragms. The low oil fill of this design has very little temperature effect and outstanding accuracy.

(1) Sigma (�) is a statistical symbol to designate the stan-dard deviation from the mean value of normal distribu-tion.

Pressure-172

FeaturesThe Model 2088 provides accurate, stable, and reliable pressure measurement in your most difficult applications. Its small compact design allows it to be directly connected to your process providing a quick, easy, and cost effective installation.

The Model 2088 standard process connection is 1/2 inch NPT but a variety of optional connections area available. Optional connections range from multiple threaded connections to our full line of manifolds and remote diaphragm seals that provide solutions for virtually any connection.

The Model 2088 also features a fully configurable digital LCD meter that displays pressure and diagnostic information. The information displayed is directly from the microprocessor which accounts for its accuracy and reliability.

Rosemount Pressure Solutions

Model 3051S Series of Instrumentation

Scalable pressure, flow and level measurement solutions improve installation and maintenance practices. See product data sheet 00813-0100-4801.

Model 3095MV Mass Flow Transmitter

Accurately measures differential pressure, static pressure and process temperature to dynamically calculate fully compensated mass flow. See product data sheet 00813-0100-4716.

Model 305 and 306 Integral Manifolds

Factory-assembled, calibrated and seal-tested manifolds reduce on-site installation costs. See product data sheet 00813-0100-4733.

Model 1199 Diaphragm Seals

Provides reliable, remote measurements of process pressure and protects the transmitter from hot, corrosive, or viscous fluids. See product data sheet 00813-0100-4016.

Model 1195 Integral Orifice and ProPlate/Mass ProPlate Flowmeters

Convenient ready-to-install assembly designed for small-bore flow measurement of any clean gas, liquid, or vapor. See product data sheet 00813-0100-4686.

Annubar Flowmeter Series

A series of highly accurate and repeatable insertion-type flowmeters available in 2-in. to 72-in. (50.8 to 1829 mm) line sizes. See product data sheet 00813-0100-4809.

Model 405P Compact Orifice

A wafer style primary element with an integral three-valve manifold. See product data sheet 00813-0100-4810.

Page 3: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

Specifications

Functional Specifications

ServiceLiquid, gas, and vapor applications

Ranges

OutputCode S: 4�20 mA dcCode M: 1-5 volt dc, low power(Outputs are directly proportional to the input pressure)

RangedownCode S: 20 to 1Code M: 10 to 1

Load LimitationsReverse polarity protection is standard. Maximum loop resistance is determined by the power supply voltage as described by the following equations:

Power SupplyExternal power supply required. Transmitter operates on 10.5�36 V dc with no load. Reverse polarity protection is standard.

RangeMinimum Span (Smart)

Minimum Span (Low Power)

URL/Max. span/ Sensor Limit

0 N/A 1 psi (69 mbar)

8 psi(552 mbar)

1 1.5 psi (103 mbar)

3 psi(207 mbar)

30 psi(2.06 bar)

2 7.5 psi (517 mbar)

15 psi(1 bar)

150 psi (10.34 bar)

3 40 psi(2.76 bar)

80 psi(5.5 bar)

800 psi (55.15 bar)

4 200 psi(13.8 bar)

400 psi27.6 bar)

4000 psi (275.79 bar)

2

Load

(ohm

s)

Operating Region

Power Supply Output Code S (dc Volts)

(1) For hazardous location approvals, power supply must not exceed 36 V.

(2) For CENELEC Ex ia approval, the power supply must not exceed 30 volts

Max. Loop Resistance = 43.5 (Power Supply Voltage � 10.5)

Zero Elevation and SuppressionZero can be suppressed between atmosphere or 0 psia and upper range limit, provided the calibrated span is equal to or greater than the minimum span, and the upper range value does not exceed the upper range limit. For vacuum calibrations, the compound range option is available (Option Code CR).

Compound Range CapabilitySelect the Compound Range (CR) option for use in negative gage pressure applications. An enhanced sensor is in transmitters with the CR option code.

Overpressure LimitsRanges 0 and 1: 120 psig maxAll other ranges: twice the upper range limit

Time ResponseTime Constant: 200 millisecondsDead time: less than 50 msUpdate rate: 20 times per second minimum

Temperature Limits

Process Silicone fill sensor: �40 to 250 °F (�40 to 121 °C)Inert fill sensor: �22 to 250 °F (�30 to 121 °C)

Ambient: �40 to 185 °F (�40 to 85 °C)�4 to 175 °F (�20 to 80 °C) with LCD meter

Storage: �50 to 230 °F (�46 to 110 °C)�40 to 185 °F (�40 to 85 °C) with LCD meterProcess Temperatures above 185 °F (85 °C) require derating the ambient limits by a 1.5:1 ratio:

Humidity Limits0�100% relative humidity

Volumetric DisplacementLess than 0.00042 cm3

185 Process Temp 185–( )1.5

-----------------------------------------------------------–=Maximum AmbientTemperature in °F

85 Process Temp 85–( )1.5

--------------------------------------------------------–=Maximum AmbientTemperature in °C

Pressure-173

Page 4: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EA

Catalog 2002 � 2003Model 2088

Turn-on Time

Output Code S2.0 seconds, no warm-up required

Ouput Code M0.3 seconds maximum at reference operating conditions

Failure Mode

Output Code SIf self-diagnostics detect a sensor or microprocessor failure, the analog signal is driven either high or low to alert the user. High or low failure mode is user-selectable with a jumper on the transmitter. The values to which the transmitter drives its output in failure mode depend on whether it is factory-configured to standard or NAMUR-compliant operation. The values for each are as follows:

Standard OperationLinear Output:3.9 ≤ I ≤ 20.8Fail High:I ≥ 21.75 mALow:I ≤ 3.75 mA

NAMUR-Compliant OperationLinear Output:3.8 ≤ I ≤ 20.5Fail High: I ≥ 22.5 mALow:I ≤ 3.6 mA

Transmitter Security (output code S)Activating the transmitter security function prevents changes to the transmitter configuration, including local zero and span adjustments. Security is activated by an internal switch.

Performance Specifications(Zero-based spans, reference conditions, silicone oil fill, and 316 SST isolating diaphragm.)

Reference Accuracy

Output Code S±0.20% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability

Output Code M±0.25% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability

Ambient Temperature EffectExpressed as a total effect per 100 °F (56 °C)

Output Code S± (0.3% URL + 0.3% of span) from �40 to 185 °F

Pressure-174

Output Code M

Total effect includes zero and span effects.

Stability

Output Code S±0.10% of upper range limit for 12 months

Output Code M±0.25% of upper range limit for 12 months

Vibration EffectLess than ±0.1% of upper range limit when subjected to vibration of: peak to peak constant displacement of 4 mm (5�15 Hz) and constant acceleration of 2 g (15�150 Hz) and 1 g (150�2000 Hz).

Power Supply EffectLess than 0.01% of calibrated span per volt

Mounting Position EffectZero shift of up to 1.2 inH2O (0.30 kPa), which can be calibrated out. No span effect.

RFI EffectLess than ±0.25% of upper range limit from20�1000 MHz at 30 V/m with leads in conduit. Less than ±0.25% of upper range limit from 20-1000 MHz at 10 V/m with unshielded twisted pair (no conduit).

Transient Protection Limits

IEEE 587 Category B6 kV Crest (1.2 � 50 �s)3 kV Crest (8 � 20 �s)6 kV Crest (0.5 �s by 100 kHz)

IEEE 472SWC 2.5 kV Crest,1 MHz waveform

General SpecificationsTested to IEC 801-3

Temperature Ranges 1�4 Range 0�40 to 0 °F

(�40 to �18 °C)±(0.7% URL + 0.8% Span)

±(1.3% URL + 0.5% Span)

0 to 140 °F(�18 to 60 °C)

±(0.5% URL + 0.5% Span)

±(1.0% URL + 0.5% Span)

140 to 185 °F (60 to 85 °C)

±(0.7% URL + 0.8% Span)

±(1.3% URL + 0.5% Span)

Page 5: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

Physical Specifications

Electrical Connection1/2�14 NPT, M20 � 1.5 (CM20), PG 13.5, or G 1/2 female (PF 1/2 female) conduit entry

Process Connection1/2�14 NPT female, DIN 16288 G 1/2 male, RC 1/2 female (PT 1/2 female), M20 � 1.5 (CM20) male

Process Wetted Parts

Isolating Diaphragm316L stainless steel or Hastelloy C-276

Process Connector316L stainless steel CF-3M (Cast version of 316L SST, material per ASTM_A743) or Hastelloy C-276

Non-wetted Parts

Electronics HousingLow-copper aluminum, NEMA 4X, IP65, IP67,CSA enclosure Type 4X

PaintPolyurethane

Cover O-ringsBuna-N

Fill FluidSilicone or inert fill

WeightSmart: Approximately 2.44 lb (1.11 kg)Low Power: Approximately 1.9 lb (0.86 kg)

TaggingThe transmitter is tagged, at no charge, in accordance with customer requirements. All tags are stainless steel. The standard tag is wired to the transmitter. Tag character height is 1/8 in. (0.318 cm). A permanently attached tag is available upon request.

Accessory Block and Bleed Valve (S5 Option)Model 306 Integral Manifold is pre-assembled to transmitter and leak checked.

Pressure-175

Page 6: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EA

Catalog 2002 � 2003Model 2088

Hazardous Locations Certifications

Ordinary Location CertificationFactory Mutual (FM) Approval

As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

Hazardous Locations Certifications Factory Mutual (FM) ApprovalE5 Explosion Proof for Class I, Division 1, Groups B, C, and D.

Dust-Ignition Proof for Class II, Division 1, Groups E, F, G, Class III, Division 1, indoor and outdoor (NEMA 4X) hazardous locations; factory sealed.

I5 Instrinsically safe for use in Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G; and Class III, Division 1 when connected in accordance with Rosemount drawing 02088-1018. Non-incendive for Class I, Division 2, Groups A, B, C, and D.

K5 Combination of E5 and I5

I5 Connection Parameters

Canadian Standards Association (CSA) ApprovalsC6 Explosion Proof for Class I, Division 1, Groups B, C, and D.

Dust-Ignition Proof for Class II, Division 1, Groups E, F, G, Class III, indoor and outdoor hazardous locations. CSA enclosure Type 4X; factory sealed. Suitable for Class I, Division 2, Groups A, B, C, and D. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. Temp. Code T3C. (Intrinsically safe when connected with approved barriers in accordance with Rosemount drawing 02088-1024.)

CSA I. S. Connection Parameters

FM I5 Connection Parameters Approved GroupsVmax = 30 V dc A�GImax = 165 mA A�GImax = 225 mA C�GPmax = 1 W A�GCi = 0.01 �F A�GLi = 10 �H A�GLi = 1.06 mH (T1 option) A-GI max = 160 mA (T1 option) A, B

CSA I. S. Connection Parameters Approved GroupsVmax = 30 V dc/Rmin = 330 Ohms A, B, C, D

Vmax = 28 V dc/Rmin = 300 Ohms A, B, C, D

Vmax = 25 V dc/Rmin = 200 Ohms A, B, C, D

Vmax = 22 V dc/Rmin = 180 Ohms A, B, C, D

Vmax = 30 V dc/Rmin = 150 Ohms C, D

Pressure-176

BASEEFA/CENELEC Intrinsic Safety ATEX ApprovalAnalogI1 Certificate No.: 90C2158

EEx ia IIC T5 (Tamb = 40 °C)EEx ia IIC T4 (Tamb = 70°C)

ATEX I1 Certificate No.: BAS00ATEX1166X

ATEX Marking: II 1GEEx ia IIC T5 (Tamb = �55 to 40 °C)EEx ia IIC T4 (Tamb = �55 to 70°C)

BASEEFA/CENELEC I1 Connection Parameters

SPECIAL CONDITIONS FOR SAFE USEWhen the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a 500V rms test to case. This must be taken into account on any installation in which it is used, for example by assuring that the supply to the apparatus is galvanically isolated.

N1 BASEEFA Type N Certification (Ex 97Y4277X) Ex N IIC T5 (Tamb = -40 to 70 °C)

Special Conditions for Safe Use (x):When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a 500 V r.m.s. test to case. This must be taken into account on any installation in which it is used, for example, by assuring that the supply to the apparatus is galvanically isolated.

KEMA/CENELEC ATEX Flameproof Certification No. KEMA97ATEX2378ATEX Marking: Ex II 1/2 GED EEx d IIC T6 (Ta = -20 °C to 40°C)

T4 (Ta = -20 °C to 80 °C)

JIS Flameproof CertificationE4 Ex d IIC T6 (Tamb = 85 °C)

Combinations of ApprovalsKB K5 and C6 CombinationKH K5, ED and I1 Combination

Parameters GroupsWmax = 0.67 W AnalogCeq = 0.06 AnalogUi = 30 V dc Analog and SmartIi = 200 mA Analog and SmartPi = 0.9 W SmartCi = 0.012 �F Smart

Page 7: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

Dimensional Drawings

Model 2088

Model 2088 Low Power

Transmitter Field Wiring

2 � ½�14 NPT*Conduit

ConnectionTerminal

Connections

5.0 (125)

OptionalMeter Cover

TransmitterCircuitry

4.3 (110) Max.

0.75 (20)Clearancefor CoverRemoval

Certifications Tag

2 �¼�20 UNC-2BMounting Holes

½�14 NPT Female�

Process Connection

3.9 (100)

5.4 (140)Typical

4.7 (120)

� M20 � 1.5 Female (CM20), PG 13.5, and G 1/2 Female

(PF 1/2) also available as options

0.75 (20) Clearancefor Cover Removal

Terminal Connections

CertificationsTag

3.80 (97) Max.4.36 (119)

OptionalMeter Cover

TransmitterCircuitry

2 � ½�14 NPTConduit

Connection

Nameplate

2 �¼�20 UNC-2BMounting Holes

2.80m (71)

4.29 (109)

5.10 (130)Typical

½�14 NPT Female�

Process Connection� DIN 16288 G 1/2 Male, RC 1/2 Female (PT 1/2), and M20 � 1.5 Male

(CM20) also available as options 2088

-208

8A07

A, B

07A;

208

8S-2

088A

07A,

B07

A

MODEL 2088 ANALOG, 1�5 V dc (LOW POWER)MODEL 2088 SMART, 4�20 mA dc

Power Supply

Signal Loop may be grounded at any single point, or may be left ungrounded.

Shield

Power Supply

HART® Communicator may be connected at any termination point in the signal loop

A to D Converter

2088

S-20

88C

02C

; 208

8B02

F

Pressure

-177
Page 8: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EA

Catalog 2002 � 2003Model 2088

Transmitter Mounting Configurations with Optional Mounting Bracket

PIPE

MO

UN

TIN

GPA

NEL

MO

UN

TIN

G

6.0 (150)2.5 (63)

3.5(90)

5.0(140)

1.25 (32)HEX

3.0 (80)

2-inch U-Boltfor Pipe Mounting

Smart:4.0 (100)

6.2(160)2.8

(70)

4.75 (120)

7.0 (175)

NOTEDimensions are in inches (millimeters).

1.30 (33)

2.8 (70)

5/16× 1½ Boltsfor Panel Mounting

(not supplied)

5/16× 1½ Boltsfor Panel Mounting

(not supplied)

2088

S-20

88A0

4A, B

04A,

C04

A; 2

088-

2088

A04A

, A04

B

Pressure-178

Page 9: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

Ordering InformationModel Product Description2088 Pressure TransmitterCode Transmitter Type

A AbsoluteG Gage

Code Range Minimum Span (Smart) Minimum Span (Low Power) URL/Max.span/Sensor Limit0(1) 0-8 psi (0-552 mbar) N/A 1 psi (69 bar) 8 psi (552 mbar)1 0�30 psi (0�2 bar) 1.5 psi (103 mbar) 3 psi (207 mbar) 30 psi (2.06 bar)2 0�150 psi (0�10.3 bar) 7.5 psi (517 mbar) 15 psi (1 bar) 150 psi (10.34 bar)3 0�800 psi (0�55.15 bar) 40 psi (2.76 bar) 80 psi (5.5 bar) 800 psi (55.15 bar)4 0�4,000 psi (0�275.79 bar) 200 psi (13.8 bar) 400 psi (27.6 bar) 4000 psi (275.79 bar)

Code OutputM 1-5 V dc Low PowerS 4�20 mA dc/Digital HART Protocol

MATERIALS OF CONSTRUCTIONCode Process Connection Isolating Diaphragm Oil Fill22(2) 316L SST 316L SST Silicone33(2) Hastelloy C-276(3) Hastelloy C-276(3) Silicone2B(2) 316L SST 316L SST Inert(3)

Code Process ConnectionA(4) ½�14 NPT FemaleB DIN 16288 G ½ MaleC RC ½ Female (PT ½ Female)D M20 � 1.5 Male (CM20 Male)

Code Conduit Thread1 ½�14 NPT2 M20 � 1.5 Female (CM20)3 PG 13.54 G ½ Female (PF ½ Female)

Continued on next page

Pressure-179

Page 10: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EA

Catalog 2002 � 2003Model 2088

Code Options

T1(5)Accessory OptionsTransient Protection

M5 LCD Meter, scaled 0�100%M7 LCD Meter, Special ConfigurationB4 SST Mounting Bracket with SST BoltsS1 Attachment of one Diaphragm Seal S5 Assembly to Model 306 Integral Manifold

I1 (6)Hazardous Locations Certifications OptionsBASEEFA Intrinsic Safety Approval

N1(6) BASEEFA Type N CertificationED(6) KEMA (CENELEC) Flame-Proof ApprovalC6 CSA Explosion-Proof, Intrinsic Safety, and Non-Incendive ApprovalK6 CSA/CENELEC Explosion-Proof and Intrinsic Safety Approval CombinationE5 FM Explosion-Proof ApprovalI5 FM Non-Incendive and Intrinsic Safety ApprovalK5 E5 and I5 CombinationE4 JIS Flameproof Certification (available with Output Code S, smart option, Conduit Thread

Code 4, G1/2 Female, and with or without LCD meter)KB K5 and C6 CombinationKH K5, ED, and I1 CombinationDW NSF Drinking Water Approval (limited to 316 SST diaphragm with 1/2-14 NPT process connection

CRConfiguration OptionsCompound Range Calibration Capability

P1 Hydrostatic TestingP2 Cleaning for Special ServiceP8 0.1% Accuracy to 10:1 TurndownQ4 Calibration CertificateQ8 Material Traceability per EN 10204 3.1.BC4 Analog Output Levels Compliant with NAMUR Recommendation NE43, 18-January-1994 (Available with Output Code S only)C9 Software Configuration (Available with Output Code S only)

(1) Range 0 is not available with Output Code S. Range 0 turndown is 8 to 1.

(2) Meets NACE material recommendations.

(3) Inert fill fluid and Hastelloy materials are not available with Range 0 transmitters.

(4) Use Process Connection code A when ordering the Integral Manifold (S5 Option).

(5) Available with Approvals E5, ED, I5, C6, and K5.

(6) Not available with low-power option (Option code M).

00806-0100-4690EnglishRev. AA

Pressure-180

Page 11: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

Configuration Data Sheet

★ = Defaults

CONFIGURATION DATA SHEET

Customer _____________________________________________ P.O. No. ________________________________________________

Model No. _____________________________________________ Line Item _______________________________________________

SST Tag No: ____________________________________________________________________________________________________

Software Tag: |__|__|__|__|__|__|__|__|

OUTPUT INFORMATION: (Software Selectable)

Pressure Units: � InH2O ★ � psi ★ � Pa � ftH2O

� inHg � bar � kPa � g/cm2

� mbar � Torr � mmH2O � inH2O at 4 °C(1)

� Atm � kg/cm2 � mmHg � mmH2O at 4 °C(1)

Range Points: 4mA = |__|__|__|__|__|__|__| (0) ★ 20mA = |__|__|__|__|__|__|__| (URL) ★ (2)

Damping:(1) � 0.00 seconds � 0.05 seconds � 0.10 seconds � 0.20 seconds

� 0.40 seconds★ � 0.80 seconds � 1.60 seconds � 3.20 seconds

� 12.8 seconds � 25.6 seconds

(1) Not available with low power output

(2) Default values may be different outside the U.S.A. Consult your Rosemount Sales Representative.

TRANSMITTER INFORMATION: (Software Selectable)

Descriptor:(1) |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__| (16 Characters)

Message:(1) |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__| (32 Characters)Date:(1) � �/� �/� �

Day/Month/YearLocal Span and Zero: � Enabled★ � Disabled

(1) C9 Option required for configuration of this parameter.

Pressure-181

Page 12: Catalog 2002 Œ 2003 Model 2088 Absolute and Gage Pressure … · 00813-0100-4690, Rev EA Model 2088 Catalog 2002 Œ 2003 Pressure-174 Turn-on Time Output Code S 2.0 seconds, no warm-up

Product Data Sheet00813-0100-4690, Rev EACatalog 2002 � 2003 Model 2088

LCD METER INFORMATION: (Software Adjustable - M7 option must be specified in model number)Meter Display Type:(1) � Eng. Units Only � Alternate Eng. Units & % of Range★

� % of Range Only � Alternate Eng. Units & Custom Display(2)

� Custom Display Only(2) � Alternate % of Range & Custom Display(2)

Custom Display Configuration: Decimal Point Position (fixed)(Must be filled out if Custom Display is selected as meter type) Indicate decimal point location X� X� X� X� X�

Enter Lower Range Value (Decimal point must be in the same position as specified above.)(circle sign) + � � � � � � Default is

+000.00Enter Upper Range Value (Decimal point must be in the same position as specified above.)

(circle sign) + � � � � � � Default is +100.00

Custom Units Available characters: A-z, 0-9, /, *, %, (blank)� � � � � Default is

%RNGE

(1) C9 Option required for configuration of this parameter.(2) Not available with low power output.

HARDWARE SELECTABLE INFORMATION

Alarm Option: � High★ � LowTransmitter Security: � Off★ � On

NOTE: Specify C4 Option in model structure when ordering NAMUR-compliant alarm and saturation limits.(1)

(1) Available with smart electronics only.

SIGNAL SELECTION: (Software Selectable)

� 4�20 mA with simultaneous digital signal based on HART protocol★� Burst mode of HART digital process variable(1)

Burst mode output options:� Primary variable in engineering units� Primary variable in percent of range� All dynamic variables in engineering units� All dynamic variables in engineering units and the primary variable mA value

� Multidrop Communication(1) (2) Choose transmitter address (1-15)(3): _______________

(1) C9 Option required for configuration of this parameter.

(2) This option fixes the transmitter analog output at 4mA.

(3) Default address is 1 if multidrop communication is selected.

Emerson Process Management

© 2002 Rosemount Inc. All rights reserved.

¢00813-0100-4690*¤

Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.HART is a registered trademark of the HART Communications Foundation.Hastelloy and Hastelloy C-276 are registered trademarks of Haynes International.PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.All other marks are the property of their respective owners.

Rosemount Inc.8200 Market BoulevardChanhassen, MN 55317 USAT (U.S.) 1-800-999-9307T (International) (952) 906-8888F (952) 949-7001

www.rosemount.com

Fisher-Rosemount GmbH & Co.Shipping Address:Argelsrieder Feld 382234 WesslingGermanyTel 49 (8153) 9390Fax 49 (8153) 939172

Fisher-Rosemount Singapore Pte Ltd.1 Pandan CrescentSingapore 128461Tel (65) 777-8211Fax (65) [email protected]