============================================================================================3 Health Check Before Upgrade============================================================================================
3.4.1 Check Cell/Link/Device status< Read MO's ><1>1. lt ^utrancell|^pch|rach|fach|hsdsch|eul|iublink|nbap|nodesync2. lt mtp3b|sccp|m3ua|sctp|ranap|rnsap|gigabit|ipacc|ipinter|ipeth|ether|vcltp3. lt ccdev|dcdev|pdr|packetd|spm|plugin|spdev|rncfeature|stp|aal|upgradepa
< Alarm ><2>1. alt
< Link status ><3>1. st sccp|mtp3b|m3ua|sctp|ranap|rnsap2. st sccp|mtp3b|m3ua|sctp|ranap|rnsap dis
3. st iublink4. st iublink dis5. lst iublink dis
6. lst vcltp dis7. pget m3ua|sctp
8. st gigabit|ipaccesshost
9. sget GigaBitEthernet link.state|activelink
10. sget ipint.* (0|1)state
11. st IpEthPacketDataRouter
12. pmx IpEthPacketDataRouter
< Traffic status ><4>1. lh ranapmp ueregprint sum2. lh ranapmp ranap status3. lh ranapmp ranap conn4. lh ranapmp rnsap status5. lh ranapmp rnsap dumpRoTable
< Cell status ><5>1. st utrancell2. st utrancell dis3. lst utrancell4. lst utrancell dis5. str
< Device status ><6>1. st ccdev|dcdev|pdr|packetd|spm|plugin2. st ccdev|dcdev|pdr|packetd|spm|plugin dis3. std4. lh mod drh_dcrh_topdata5. sget spdevicepool6. lh mod drh_ccrh_topdata7. cedr8. lh mod drh_trbr_data iphost
< Other status ><7>1. cabx2. lgaevsmor 5h3. lgusrm 5h4. lh all llog -l5. cabr6. dump list -a7. all err8. hget rncfeature state9. readclock
10. lst EthernetSwitchPort11. sget switchportstp stprole12. each capi check lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> x lh ranapmp capi type pri <x> lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> y lh ranapmp capi type pri <y> 13. invr14. sget switchportstp manualpathcost15. sget RabHandling=1 maxAllowedGbrUlPsSpeech
< Disk capacity ><8>1. cabd2. lh coremp vols /c3. lh coremp vols /d4. lh coremp ls /c/loadmodules |awk '{print $1}' |uniq -c5. lh coremp ls /d/loadmodules |awk '{print $1}' |uniq -c
< Initializing trace ><9> only nighttime preHC1. lh mod te default -restart2. lh mod te default *
< Check trace status ><10>1. lh mp te s -restart2. cabe (if using latest moshell, lh mp fte s.
< DB check ><11> only daytime1. ftget /d/configuration/cv/<latest CV name>2. nowshell -d db.dat (from cv folder on tp server.3. dbc db.dat (on offline mode.
3.4.2 Check the status of Reliable Programs1. lh mp sma -all
3.4.3 Check the FTC state in Main MP1. lh coremp mirror s2. getAttrObj me
FTC switch<<< RNC3810 >>>1) bl 0011002) acc 001100 manualrestart3) getAttrObj me4) deb 0011005) lh coremp mirror s6) getAttrObj me
<<< RNC3820 >>>1) bl 0024002) acc 002400 manualrestart3) getAttrObj me4) deb 0024005) lh coremp mirror s6) getAttrObj me
3.4.4 Check Traffic availability (Night)1. lh ranapmp ueregprint sum2. pmrup -m 1
3.4.5 Check the Flash disk failure in all MPs (Day)1. lh mp ls /d |grep -i not2. lh mp ls /c |grep -i not
3.5.1 Check the number of CVs (Day)
1. cvls2. cvls
3.5.2 Set the latest CV in Rollback list and check the rollback list (Night)1. cvls2. cv rbset < Latest CV >3. cvls4. lh coremp cat /d/rollback.lst
3.5.3 Backup the cv.ptr (Night)1. cvcu2. cat /d/cv.ptr3. cp /d/cv.ptr /d/cv.ptr.org4. cat /d/cv.ptr.org5. cat /d/cv.ptr
=For emergency Recovery=> reload -- (minus minus)> cp cv.ptr.org cv.ptr> reload========================
3.6 Make a connection to Serial Console Server (Day, Night)1. tp machine> telnet -e "^A" <ip address of gateway server> User/Pass: support/support123
2. serial server> telnet -e "^A" <host name> <port no> User/Pass: support/support123
3.7 Install the License Key File (Day)1. license server2. license key
3. license lkf
3.8 Deletion of Aal0TpVccTp1. alt2. lst aal0TpVccTp3. trun <MO script for RNC>4. alt5. lt aal0TpVccTp6. lst aal0TpVccTp7. mobatch <MOS script for RBS> (e.g.)mobatch -p 1 TRNC70_AAL0_cleanup_RBSlist.txt RBS_TRNC70_AAL0_cleanup.mos8. alt
3.9.1 Check Upgrade Controll file (Day/Night)
cksum CXP9014711%4_R2EA.xmlcat CXP9014711%4_R2EA.xml | egrep "confirm|WaitForConfirm_BeforeRestart"
3.9.2 Get MO dump<<< RNC3810 >>>Terminal 11. l+m [Node]_dump_[SWname]_beforeUp.log2. lhsh 001200 capi prio3. lt all4. lhsh 001200 capi prio5. kget6. lhsh 001200 capi prio7. l-
Terminal 21. l+ [Node]_dump_[SWname]_beforeUp_ldmon.log2. for 20003. lhsh 001200 capi prio4. done
<<< RNC3820 >>>Terminal 11. l+m [Node]_dump_[SWname]_beforeUp.log2. lhsh 000500 capi prio3. lt all
4. lhsh 000500 capi prio5. kget6. lhsh 000500 capi prio7. l-
Terminal 21. l+ [Node]_dump_[SWname]_beforeUp_ldmon.log2. for 20003. lhsh 000500 capi prio4. done
============================================================================================4 RNC Software Install============================================================================================4.4 Check and Store the Si CV for recovery GPB (Night)1. lh coremp cv csum <Si_xxxx>2. ftget /d/configuration/cv/Si_xxxx
4.5 Put prepared CV to increase heap size for prevention of cyclic restarts after rollback
ftput xRNCxx_prepared_CV_for_Rollback /d/configuration/cv/ls /d/configuration/cv/
============================================================================================5 RNC Software Upgrade============================================================================================
5.1 Remove the PM scanners for user-defined1. pst2. pst
5.3 Switch Targetmonitor to Active coreMP1. lt ReliableProgramUniter 2. pr ReliableProgramUniter 3. lh coremp sma -all (Find the targetmonitor RPU)4. lsget ReliableProgramUniter userLabel target 5. sget ReliableProgramUniter=xxxxxxxx (xxxx = ReliableProgramUniterId)
6. acl ReliableProgramUniter=xxxxxxxxxxx (xxxx = ReliableProgramUniterId) 7. acc ReliableProgramUniter=xxxxxxxxxxx switch (xxxx = ReliableProgramUniterId) 8. sget ReliableProgramUniter=xxxxxxxx 9. lsget ReliableProgramUniter userLabel target 10. lh coremp sma -all (Find the targetmonitor RPU)
<<< RNC3810 >>>11. sget ReliableProgramUniter=xxxxxx 12. set ReliableProgramUniter=xxxxxxx admActiveSlot Subrack=MS,Slot=1013. set ReliableProgramUniter=xxxxxxx admPassiveSlot Subrack=MS,Slot=1114. sget ReliableProgramUniter=xxxxxx (confirm right configuration)<<< RNC3820 >>>11. sget ReliableProgramUniter=xxxxxx 12. set ReliableProgramUniter=xxxxxxx admActiveSlot Subrack=MS,Slot=513. set ReliableProgramUniter=xxxxxxx admPassiveSlot Subrack=MS,Slot=2414. sget ReliableProgramUniter=xxxxxx (confirm right configuration)
15. lh coremp sma -all (Find the targetmonitor RPU)
(Extra info)<<< RNC3810 >>>1. lhsh 001000 sma -all 2. sget ReliableProgramUniter rpuid <RPU id> 3. sget ReliableProgramUniter=<MO identity> <<< RNC3820 >>>1. lhsh 000500 sma -all 2. sget ReliableProgramUniter rpuid <RPU id>
3. sget ReliableProgramUniter=<MO identity>
5.4 Perform Software upgrade
1.lt upgradepackage2.pr upgradepackagesget UpgradePackage=CXP9014711/4_R2EA prog|stat3.actl UpgradePackage=CXP9014711/4_R2EAacc UpgradePackage=CXP9014711/4_R2EA rebootNodeUpgrade
5.5 Upgrade Status and KPI Monitoring1. sget [UpgradePackage] state|prog2. pmrup -m 1
5.6 Upgrade restart execution
sget UpgradePackage=CXP9014711/4_R2EA state|prog
actl UpgradePackage=CXP9014711/4_R2EAacc UpgradePackage=CXP9014711/4_R2EA confirmUpgrade
5.7.1 Check the UE connectivity to the Core network<<< RNC3810 >>>1. l+ xrncxx_PostQHC.log2. lhsh 001700 ueregprint sum3. lhsh 001700 ranap status4. lhsh 001700 ranap conn5. lhsh 001800 rnsap status6. lhsh 001800 rnsap conn7. lgevsmur 30m
<<< RNC3820 >>>1. l+ xrncxx_PostQHC.log2. lhsh 002200 ueregprint sum3. lhsh 000700 ranap status4. lhsh 000700 ranap conn5. lhsh 002200 rnsap status6. lhsh 002200 rnsap conn7. lgevsmur 30m
5.7.2 Check ET-M4 Overload1. lgsemr 10m2. lhsh xxxxxx(target ETB) capi tot
5.7.3 Check program crashes after Upgrade (CSR1783379)1. lgsemr 10m
================================a) Terminal 1 (logfile1) repeatably collect:for ever;lhsh 000700 rof_info_esig lap;lhsh 000700 poolinfo -lwait 1done
b) Terminal 2, (logfile2) repeatably collect:for ever
;sctphost_stat -assoc -all;lhsh 000700 rof_link_counterswait 1done
c) Terminal 3, (logfile3) repeatably collect:for ever;lhsh 000700 poolinfo -l CXC1720925_R74G39wait 1done
d) Terminal 4, (logfile4) collect:with telnet >lhsh 000700 ps|grep RnhLmRanapCPT --- check pid>lhsh 000700 ps|grep Scc_server_proc --- check pide.g.)SQRNC12> lhsh 000700 ps|grep RnhLmRanapCPT00010320 RnhLmRanapCPT p23 CXC1727616%4_R1JA04 161 rcv (RncLmRanap)SQRNC12> lhsh 000700 ps|grep Scc_server_proc000101d5 Scc_server_proc p19 CXC1720925_R74G39 50 rcv (SccServer)
>lhsh 000700 sigs 000101d5 >lhsh 000700 sigs 00010320
then moshellfor ever;lhsh 000700 sigs 000101d5;lhsh 000700 sigs 00010320wait 1done
================================
2. lgsemr 10m3. cv cu
(RNC3810)4. lhsh 001000 sma -all lhsh 001100 sma -all5. cv cu6. lgsemr 10m7. lhsh 001000 sma -all lhsh 001100 sma -all alt8. lst 0010009. bl 00100010. lst 00100011. lhsh 001000 sma -all lhsh 001100 sma -all12. alt13. lst 00100014. deb 00100015. lst 00100016. lgsemr 10m
17. lhsh 001000 sma -all lhsh 001100 sma -all
(RNC3820)4. lhsh 000500 sma -all lhsh 002400 sma -all5. cv cu6. lgsemr 10m7. lhsh 000500 sma -all lhsh 002400 sma -all alt8. lst 0005009. bl 00050010. lst 00050011. lhsh 000500 sma -all lhsh 002400 sma -all12. alt13. lst 00050014. deb 00050015. lst 00050016. lgsemr 10m17. lhsh 000500 sma -all lhsh 002400 sma -all
5.7.4 Confirm Mirroring to be finished1. lh coremp mirror s2. getAttrObj me
5.7.5 Normality check< Read MO's ><1>1. lt ^utrancell|^pch|rach|fach|hsdsch|eul|iublink|nbap|nodesync2. lt mtp3b|sccp|m3ua|sctp|ranap|rnsap|gigabit|ipacc|ipinter|ipeth|ether|vcltp3. lt ccdev|dcdev|pdr|packetd|spm|plugin|spdev|rncfeature
< Alarm ><2>1. alt
< Link status ><3>1. st sccp|mtp3b|m3ua|sctp|ranap|rnsap dis2. st gigabit|ipaccesshost3. sget GigaBitEthernet link.state|activelink4. sget ipint.* (0|1).state5. st IpEthPacketDataRouter6. lpget m3ua pmnoofdatamsg (Check the counter values increases gradually)
< Cell status ><4>1. st utrancell dis2. lst utrancell|pch|rach|fach|hsdsch|eul dis3. str
< Device status ><5>1. st ccdev|dcdev|pdr|packetd|spm|plugin dis2. std
< Other status ><6>1. lgaevsmour 1h
<RNC3810>2. each capi check lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> x lh ranapmp capi type pri <x> lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> y lh ranapmp capi type pri <y> <RNC3820>2. each capi check (Repeat the following for 3 times) lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> x lh sccpmp capi type pri <x> lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> y lh sccpmp capi type pri <y>
5.8 Take the node trace logs1. vii2. run dcg_datacollection_8.0r_modified_110608.mos <A> <B> e <A> Path of the log output. <B> Node name. (used for log file naming)3. (only 3810) run dcg_script_noOMS_version_090813_ES3_4_ver6.mos run dcg_script_noOMS_version_090813_ES11_12_ver6.mos
5.9 Switch Targetmonitor to Standby coreMP1. lt ReliableProgramUniter 2. pr ReliableProgramUniter 3. lh coremp sma -all (Find the targetmonitor RPU)4. lsget ReliableProgramUniter userLabel target 5. sget ReliableProgramUniter=xxxxxxxx (xxxx = ReliableProgramUniterId)
6. acl ReliableProgramUniter=xxxxxxxxxxx (xxxx = ReliableProgramUniterId) 7. acc ReliableProgramUniter=xxxxxxxxxxx switch (xxxx = ReliableProgramUniterId) 8. sget ReliableProgramUniter=xxxxxxxx 9. lsget ReliableProgramUniter userLabel target 10. lh coremp sma -all (Find the targetmonitor RPU)
<<< RNC3810 >>>11. sget ReliableProgramUniter=xxxxxx 12. set ReliableProgramUniter=xxxxxxx admActiveSlot Subrack=MS,Slot=1113. set ReliableProgramUniter=xxxxxxx admPassiveSlot Subrack=MS,Slot=1014. sget ReliableProgramUniter=xxxxxx (confirm right configuration)<<< RNC3820 >>>11. sget ReliableProgramUniter=xxxxxx 12. set ReliableProgramUniter=xxxxxxx admActiveSlot Subrack=MS,Slot=2413. set ReliableProgramUniter=xxxxxxx admPassiveSlot Subrack=MS,Slot=514. sget ReliableProgramUniter=xxxxxx
(confirm right configuration)
15. lh coremp sma -all (Find the targetmonitor RPU)
(Extra info)<<< RNC3810 >>>1. lhsh 001000 sma -all 2. sget ReliableProgramUniter rpuid <RPU id> 3. sget ReliableProgramUniter=<MO identity> <<< RNC3820 >>>1. lhsh 000500 sma -all 2. sget ReliableProgramUniter rpuid <RPU id> 3. sget ReliableProgramUniter=<MO identity>
5.10 Activate the DailyTrace1. lh all te alt status |egrep overload2.(optional) lh all te alt stop 3. lh mod te e trace1 UEH_EXCEPTION4. lh mod te e trace3 IU_IF
5. lh mod te s UEH_EXCEPTION6. lh mod te s IU_IF
7. Tp machine> ps -ef |egrep -i logsp8. Tp machine> kill -9 <processID>
9.<<< RNC3810 >>>Tokyo, tp03) /export/home/tpuser/users/p3/bin/startmon4.sh trncxxTokai, tp03) /export/home/tpuser/users/p3/bin/startmon4.sh crncxxxKansai, tp01) /export/home/tpuser/users/p3/bin/startmon4.sh krncxxx<<< RNC3820 >>>Tokyo, tp03) /export/home/tpuser/users/p3/bin/startmon4_3820.sh trncxxTokai, tp03) /export/home/tpuser/users/p3/bin/startmon4_3820.sh crncxxxKansai, tp01) /export/home/tpuser/users/p3/bin/startmon4_3820.sh krncxxx
5.11 Confirm Upgrade and monitor upgrade status
sget UpgradePackage=CXP9014711/4_R2EA prog|stat
acc UpgradePackage=CXP9014711/4_R2EA confirmupgrade
sget UpgradePackage=CXP9014711/4_R2EA prog|stat
5.13 Check the KPI after RNC restart1. pmrup -m 1 (0.25 and 0.5 should be used 1st and 2nd ROP)
5.14 Activate the User defined PM scanner1. pst
5.15 Check and WA for RANAP high load<RNC3810>1. each capi check lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> x lh ranapmp capi type pri <x> lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> y lh ranapmp capi type pri <y> <RNC3820>1. each capi check lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> x lh sccpmp capi type pri <x> lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> y lh sccpmp capi type pri <y>
2. pmr -m 1 >>> select 3) check IuSigSuc3. sget <upgradepackage MO> prog|state4. acc 001700 manualrestart5. lh ranapmp sma -all6. lt ranap7. st ranap8. lk ranap
<RNC3810>9. each capi check lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> x lh ranapmp capi type pri <x> lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> y lh ranapmp capi type pri <y> <RNC3820>9. each capi check lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> x lh sccpmp capi type pri <x> lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> y lh sccpmp capi type pri <y>
10. cvls11. acc 0 manualrestart
5.16 WA for Ranap disabled after upgrade1. lt ranap|mtp3b|m3ua|ip|aal|sccp|sctp|atmport2. alt3. lst ranap4. lk Ranap=<target ranap>
5. acl <target m3ua(SGSN1)> 6. acc <target m3ua(SGSN1)> setAutoDown7. lst M3uAssociation=<target m3ua(SGSN1)>8. acl <target m3ua(SGSN2)> 9. acc <target m3ua(SGSN2)> setAutoDown10. lst M3uAssociation=<target m3ua(SGSN2)>
11. acl <target m3ua(SGSN1)> 12. acc <target m3ua(SGSN1)> setAutoActivate13. lst M3uAssociation=<target m3ua(SGSN1)>14. acl <target m3ua(SGSN2)> 15. acc <target m3ua(SGSN2)> setAutoActivate16. lst M3uAssociation=<target m3ua(SGSN2)>
17. alt18. lst ranap19. lk Ranap=<target ranap>
20. u+ ranap_rec21. del ranap=<target ranap>22. u-23. run <created mos>
24. alt25. lst ranap26. lk ranap=<target ranap>
5.17 WA for Synchronization alarms from DUW sites(RBS operation)1. alt2. sget Synchronization3. rm /d/nss_tum_data. 4. cvls5. acc 0 manualrestart6. alt7. sget Synchronization
5.18 WA for DISABLED cells without alarm after upgrade1. st utarncell=<target sites>
(Optional)lh <MOD> te e trace1 trace6 trace7 DLCODE_CELLlh <MOD> te e trace3 trace6 trace7 HSDSCH_CONFIG_CELL lh <MOD> te e trace5 trace6 trace7 rnhCellRoC[<CELL_RO>]lh ommp te e trace6 trace7 roamFroUtranCellRoProxyC lh ommp te e trace6 trace7 roamFroHsdschRoRnhProxyClh <MOD> cellenable -cid <CELL_ID>
lh <MOD> rrt-RncLmCell info 1/1/1/1/2/1.<CELL_CAPS>/6 lh <MOD> rrt-RncLmCell history 1/1/1/1/2/1.<CELL_CAPS>/6 lh <MOD> rrt-RncLmCell system 1/1/1/1 lh <MOD> rrt-RncLmCell getattr 1/1/1/1/2/1.<CELL_CAPS> cellAlarmList lh <MOD> rrt-RncLmCell history 1/1/1/1/2/1.<CELL_CAPS>fget <AFFECTED_HSDSCH> froId
<MOD>, <CELL_ID>, CELL_CAPS> - on cedr printout pick affected cell and use values from proper columns: <MOD> - 'MOD' column <CELL_ID> - 'cid' column<CELL_RO> - value from 'ro' column <CELL_CAPS> - 'ro' column increased by 1 ('ro' + 1)
After finished taking the log, need to disable tracesh <MOD> te d trace1 trace6 trace7 DLCODE_CELLlh <MOD> te d trace3 trace6 trace7 HSDSCH_CONFIG_CELL lh <MOD> te d trace5 trace6 trace7 rnhCellRoC[<CELL_RO>]lh ommp te d trace6 trace7 roamFroUtranCellRoProxyC lh ommp te d trace6 trace7 roamFroHsdschRoRnhProxyClh <MOD> celldisable -cid <CELL_ID>
2. bl <target hsdsch>3. deb <target hsdsch>4. bl <target utrancell>5. deb <target utrancell>
6. lbl <target utrancell>7. deb <target commonCH>
8. deb <target utrancell>9. deb <target hsdsch>10. deb <target eul>
11. bl <target hsdsch> <target Eul>12. u+13. del <Eul on target cell>14. del <Hsdsch on target cell>15. u-16. run <created mos>17. deb <target hsdsch> <target Eul>
18. cvls19. acc 0 manualrestart
20. strt21. acc mod<target mod> manualrestart22. st utrancell
5.19 WA for RBS alarm 乬 Carrier_RejectSignalFromHardware 乭(RNC)1. lt ^utrancell|fach|rach|^pch|hsdsch|eul2. lst utrancell=<target site>3. alt(RBS)4. alt5. cvls6. acc 0 manualrestart7. cvls(RNC)8. alt9. lst utrancell=<target site>(RBS)10. alt
5.20 WA for RBS alarm NodeSynch_Phase_Difference_Measurement_Failed
1) Check if the alarm appeared from all RBS or not. - If all the alarm appears from all RBS, Restart active TUB borad.cabbl 000400st 000400acc 000400 manualrestart
2) Check which subracks the impacted RBS refer to.strtsget IubLink=XXX|XXX|XXX rncModuleRef(XXX = iublink name)st modX ##orstd
3) Check which Ccdevices the impacted RBS usecedr | sort -k 27 | egrep -i "XXX|XXX|XXX"(XXX = cell name)
- If the impacted RBS use a same Ccdevice, restart SPB board which has the Ccdevicebl (target board name)st XXXacc XXX manualrestart
4) Check if the impacted RBS are ATM RBS or IP RBS.strt -s XXXXXX = ms, es-1 (target subrack)
5.21 Check and WA for WCDMA carrier issue1. shget wcdmacarrier2. ex) perl ichigo_wcdmacarrier_detection_paX.pl -rnc krnc569 -carrier 5,6Tokyo, tp03) cd /home/tpuser/users/emotshi/111124_TRNC83_wcdmacarrier/ perl ichigo_wcdmacarrier_detection_pa7.pl -rnc trncxx -carrier 5,6
######not confirmed below yet #####################Tokai, tp03) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc crncxx -carrier 5,6Kansai,tp01) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc krncxx -carrier 5,6
###################################################
3. tpuser@nrjtotp03 trnc83]$ gzip -dc 2011-11-25_120* | /opt/tools/decoder/3.1t/decoder/concat_segmented_rlib_traces.pl | grep -i wcdmacarrierex)[2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 4 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 5
4. ex) perl ichigo_wcdmacarrier_remedy_paX.pl -rnc krnc569 -carrier 1,2,3,4,5,6Tokyo, tp03) perl ichigo_wcdmacarrier_remedy_pa4.pl -rnc trncxx -carrier 1,2,3,4,5,6
######not confirmed below yet #####################Tokai, tp03) perl ichigo_wcdmacarrier_remedy_pa4.pl -rnc crncxx -carrier 1,2,3,4,5,6Kansai,tp01) perl ichigo_wcdmacarrier_remedy_pa4.pl -rnc krncxx -carrier 1,2,3,4,5,6###################################################
5. ex) perl ichigo_wcdmacarrier_detection_paX.pl -rnc krnc569 -carrier 1,2,3,4,5,6Tokyo, tp03) cd /home/tpuser/users/emotshi/111124_TRNC83_wcdmacarrier/ perl ichigo_wcdmacarrier_detection_pa7.pl -rnc trncxx -carrier 1,2,3,4,5,6
######not confirmed below yet #####################Tokai, tp03) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc crncxx -carrier 1,2,3,4,5,6Kansai,tp01) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc krncxx -carrier 1,2,3,4,5,6###################################################
6. tpuser@nrjtotp03 trnc83]$ gzip -dc 2011-11-25_120* | /opt/tools/decoder/3.1t/decoder/concat_segmented_rlib_traces.pl | grep -i wcdmacarrierex)
[2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 1 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 2 [2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 3 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 4 [2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 5 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 6
7. shget wcdmacarrier
5.23.2 tnResAllocSrbHspa parameter check
lt RabHandlingsget RabHandling=1 tnResAllocSrbHspa
============================================================================================6 Health Check After Upgrade============================================================================================
6.1 Check overall RNC traffic status1. pmrup -m 1
6.2.1 Get MO dump<<< RNC3810 >>>Terminal 11. l+m [Node]_dump_[SWname]_afterUp.log2. lhsh 001200 capi prio3. lt all4. lhsh 001200 capi prio5. kget6. lhsh 001200 capi prio7. l-
Terminal 21. l+ [Node]_dump_[SWname]_afterUp_ldmon.log2. for 20003. lhsh 001200 capi prio4. done
<<< RNC3820 >>>Terminal 11. l+m [Node]_dump_[SWname]_beforeUp.log2. lhsh 000500 capi prio3. lt all4. lhsh 000500 capi prio5. kget6. lhsh 000500 capi prio7. l-
Terminal 21. l+ [Node]_dump_[SWname]_beforeUp_ldmon.log2. for 20003. lhsh 000500 capi prio4. done
6.3.1 Check Cell/Link/Device status< Read MO's ><1>1. lt ^utrancell|^pch|rach|fach|hsdsch|eul|iublink|nbap|nodesync2. lt mtp3b|sccp|m3ua|sctp|ranap|rnsap|gigabit|ipacc|ipinter|ipeth|ether|vcltp
3. lt ccdev|dcdev|pdr|packetd|spm|plugin|spdev|rncfeature|stp|aal|upgradepa
< Alarm ><2>1. alt
< Link status ><3>1. st sccp|mtp3b|m3ua|sctp|ranap|rnsap2. st sccp|mtp3b|m3ua|sctp|ranap|rnsap dis
3. st iublink4. st iublink dis5. lst iublink dis
6. lst vcltp dis7. pget m3ua|sctp
8. st gigabit|ipaccesshost
9. sget GigaBitEthernet link.state|activelink
10. sget ipint.* (0|1)state
11. st IpEthPacketDataRouter
12. pmx IpEthPacketDataRouter
< Traffic status ><4>1. lh ranapmp ueregprint sum2. lh ranapmp ranap status3. lh ranapmp ranap conn4. lh ranapmp rnsap status5. lh ranapmp rnsap dumpRoTable
< Cell status ><5>1. st utrancell2. st utrancell dis3. lst utrancell4. lst utrancell dis5. str
< Device status ><6>
1. st ccdev|dcdev|pdr|packetd|spm|plugin2. st ccdev|dcdev|pdr|packetd|spm|plugin dis3. std4. lh mod drh_dcrh_topdata5. sget spdevicepool6. lh mod drh_ccrh_topdata7. cedr8. lh mod drh_trbr_data iphost
< Other status ><7>1. cabx2. lgaevsmor 5h3. lgusrm 5h4. lh all llog -l5. cabr6. dump list -a7. all err8. hget rncfeature state9. readclock
10. lst EthernetSwitchPort11. sget switchportstp stprole12. each capi check lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> x lh ranapmp capi type pri <x> lh ranapmp capi tot lh ranapmp capi tot lh ranapmp capi prio --> select high load pri -> y lh ranapmp capi type pri <y> 13. invr14. sget switchportstp manualpathcost15. sget RabHandling=1 maxAllowedGbrUlPsSpeech
< Disk capacity ><8>1. cabd2. lh coremp vols /c3. lh coremp vols /d
4. lh coremp ls /c/loadmodules |awk '{print $1}' |uniq -c5. lh coremp ls /d/loadmodules |awk '{print $1}' |uniq -c
< Check trace status ><9>1. lh mp te s -restart2. cabe (if using latest moshell, lh mp fte s.
< DB check ><10> only daytime1. ftget /d/configuration/cv/<latest CV name2. nowshell -d db.dat (from cv folder on tp server.3. dbc db.dat (on offline mode.
6.3.2 Check the status of Reliable Programs1. lh mp sma -all
6.6.2 Check final CV1. lh coremp cv csum <xRNCxx>
============================================================================================8 Rollback============================================================================================
8.2.1 Check the UE connectivity to the Core network<<< RNC3810 >>>1. l+ xrncxx_PostQHC.log2. lhsh 001700 ueregprint sum3. lhsh 001700 ranap status4. lhsh 001700 ranap conn5. lhsh 001800 rnsap status6. lhsh 001800 rnsap conn7. lgevsmur 30m
<<< RNC3820 W10B CU3 EU11 >>>1. l+ xrncxx_PostQHC.log2. lhsh 000700 ueregprint sum3. lhsh 000700 ranap status4. lhsh 000700 ranap conn5. lhsh 000700 rnsap status6. lhsh 000700 rnsap conn7. lgevsmur 30m<<< RNC3820 W10B AD78, W11B >>>1. l+ xrncxx_PostQHC.log2. lhsh 002200 ueregprint sum3. lhsh 000700 ranap status4. lhsh 000700 ranap conn5. lhsh 002200 rnsap status6. lhsh 002200 rnsap conn7. lgevsmur 30m
8.2.2 ET-M4 Overload1. lgsemr 10m2. lhsh xxxxxx(target ETB) capi tot
8.2.3 Check program crashes after Upgrade (CSR1783379)1. lgsemr 10m2. lgsemr 10m3. cv cu
(RNC3810)4. lhsh 001000 sma -all lhsh 001100 sma -all5. cv cu6. lgsemr 10m7. lhsh 001000 sma -all lhsh 001100 sma -all alt8. lst 0010009. bl 00100010. lst 00100011. lhsh 001000 sma -all lhsh 001100 sma -all12. alt
13. lst 00100014. deb 00100015. lst 00100016. lgsemr 10m17. lhsh 001000 sma -all lhsh 001100 sma -all
(RNC3820)4. lhsh 000500 sma -all lhsh 002400 sma -all5. cv cu6. lgsemr 10m7. lhsh 000500 sma -all lhsh 002400 sma -all alt8. lst 0005009. bl 00050010. lst 00050011. lhsh 000500 sma -all lhsh 002400 sma -all12. alt13. lst 00050014. deb 00050015. lst 00050016. lgsemr 10m17. lhsh 000500 sma -all lhsh 002400 sma -all
8.2.4 Confirm Mirroring to be finished1. lh coremp mirror s2. getAttrObj me
8.2.5 Normality check< Read MO's ><1>1. lt ^utrancell|^pch|rach|fach|hsdsch|eul|iublink|nbap|nodesync2. lt mtp3b|sccp|m3ua|sctp|ranap|rnsap|gigabit|ipacc|ipinter|ipeth|ether|vcltp
3. lt ccdev|dcdev|pdr|packetd|spm|plugin|spdev|rncfeature
< Alarm ><2>1. alt
< Link status ><3>1. st sccp|mtp3b|m3ua|sctp|ranap|rnsap dis2. st gigabit|ipaccesshost3. sget GigaBitEthernet link.state|activelink4. sget ipint.* (0|1).state5. st IpEthPacketDataRouter6. lpget m3ua pmnoofdatamsg (Check the counter values increases gradually)
< Cell status ><4>1. st utrancell dis2. lst utrancell|pch|rach|fach|hsdsch|eul dis3. str
< Device status ><5>1. st ccdev|dcdev|pdr|packetd|spm|plugin dis2. std
< Other status ><6>1. lgaevsmour 1h2. each capi check (Repeat the following for 3 times) lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> x lh sccpmp capi type pri <x> lh sccpmp capi tot lh sccpmp capi tot lh sccpmp capi prio --> select high load pri -> y lh sccpmp capi type pri <y>
8.3 Take the node trace logs1. vii2. run dcg_datacollection_8.0r_modified_110608.mos <A> <B> e <A> Path of the log output.
<B> Node name. (used for log file naming)3. (only 3810) run dcg_script_noOMS_version_090813_ES3_4_ver6.mos run dcg_script_noOMS_version_090813_ES11_12_ver6.mos
8.5 Switch Targetmonitor to Standby coreMP1. lt ReliableProgramUniter 2. pr ReliableProgramUniter 3. lh coremp sma -all (Find the targetmonitor RPU)4. lsget ReliableProgramUniter userLabel target 5. sget ReliableProgramUniter=xxxxxxxx (xxxx = ReliableProgramUniterId)
6. acl ReliableProgramUniter=xxxxxxxxxxx (xxxx = ReliableProgramUniterId) 7. acc ReliableProgramUniter=xxxxxxxxxxx switch (xxxx = ReliableProgramUniterId) 8. sget ReliableProgramUniter=xxxxxxxx 9. lsget ReliableProgramUniter userLabel target 10. lh coremp sma -all (Find the targetmonitor RPU)
<<< RNC3810 >>>11. sget ReliableProgramUniter=xxxxxx 12. set ReliableProgramUniter=xxxxxxx admActiveSlot Subrack=MS,Slot=1113. set ReliableProgramUniter=xxxxxxx admPassiveSlot Subrack=MS,Slot=1014. sget ReliableProgramUniter=xxxxxx (confirm right configuration)<<< RNC3820 >>>11. sget ReliableProgramUniter=xxxxxx 12. set ReliableProgramUniter=xxxxxxx admActiveSlot Subrack=MS,Slot=2413. set ReliableProgramUniter=xxxxxxx admPassiveSlot Subrack=MS,Slot=514. sget ReliableProgramUniter=xxxxxx (confirm right configuration)
15. lh coremp sma -all (Find the targetmonitor RPU)
(Extra info)<<< RNC3810 >>>1. lhsh 001000 sma -all 2. sget ReliableProgramUniter rpuid <RPU id> 3. sget ReliableProgramUniter=<MO identity> <<< RNC3820 >>>1. lhsh 000500 sma -all 2. sget ReliableProgramUniter rpuid <RPU id> 3. sget ReliableProgramUniter=<MO identity>
8.6 Activate the DailyTrace1. lh all te alt status |egrep overload2.(optional) lh all te alt stop 3. lh mod te e trace1 UEH_EXCEPTION4. lh mod te e trace3 IU_IF
5. lh mod te s UEH_EXCEPTION6. lh mod te s IU_IF
7. Tp machine> ps -ef |egrep -i logsp8. Tp machine> kill -9 <processID>
9.<<< RNC3810 >>>Tokyo, tp04) /export/home/tpuser/users/p3/bin/startmon4.sh trncxxTokai, tp03) /export/home/tpuser/users/p3/bin/startmon4.sh crncxxxKansai, tp01) /export/home/tpuser/users/p3/bin/startmon4.sh krncxxx<<< RNC3820 >>>Tokyo, tp04) /export/home/tpuser/users/p3/bin/startmon4_3820.sh trncxxTokai, tp03) /export/home/tpuser/users/p3/bin/startmon4_3820.sh crncxxxKansai, tp01) /export/home/tpuser/users/p3/bin/startmon4_3820.sh krncxxx
8.7 Check the KPI after RNC restart
1. pmrup -m 1 (0.25 and 0.5 should be used 1st and 2nd ROP)
8.8 Activate the User defined PM scanner1. pst
8.9 Check and WA for RANAP high load<<< RNC3810 >>>1. each capi check lhsh 001700 capi tot lhsh 001700 capi tot lhsh 001700 capi prio --> select high load pri -> x lhsh 001700 capi type pri <x> lhsh 001800 capi tot lhsh 001800 capi tot lhsh 001800 capi prio --> select high load pri -> y lhsh 001800 capi type pri <y> <<< RNC3820 >>>1. each capi check lhsh 000700 capi tot lhsh 000700 capi tot lhsh 000700 capi prio --> select high load pri -> x lhsh 000700 capi type pri <x> lhsh 002200 capi tot lhsh 002200 capi tot lhsh 002200 capi prio --> select high load pri -> y lhsh 002200 capi type pri <y> 2. pmr -m 1 >>> select 3) check IuSigSuc3. sget <upgradepackage MO> prog|state4. acc 001700 manualrestart5. lh ranapmp sma -all6. lt ranap7. st ranap8. lk ranap<<< RNC3810 >>>9. each capi check
lhsh 001700 capi tot lhsh 001700 capi tot lhsh 001700 capi prio --> select high load pri -> x lhsh 001700 capi type pri <x> lhsh 001800 capi tot lhsh 001800 capi tot lhsh 001800 capi prio --> select high load pri -> y lhsh 001800 capi type pri <y> <<< RNC3820 >>>9. each capi check lhsh 000700 capi tot lhsh 000700 capi tot lhsh 000700 capi prio --> select high load pri -> x lhsh 000700 capi type pri <x> lhsh 002200 capi tot lhsh 002200 capi tot lhsh 002200 capi prio --> select high load pri -> y lhsh 002200 capi type pri <y>
10. cvls11. acc 0 manualrestart
8.10 WA for Ranap disabled after upgrade1. lt ranap|mtp3b|m3ua|ip|aal|sccp|sctp|atmport2. alt3. lst ranap4. lk Ranap=<target ranap>
5. acl <target m3ua(SGSN1)> 6. acc <target m3ua(SGSN1)> setAutoDown7. lst M3uAssociation=<target m3ua(SGSN1)>8. acl <target m3ua(SGSN2)> 9. acc <target m3ua(SGSN2)> setAutoDown10. lst M3uAssociation=<target m3ua(SGSN2)>
11. acl <target m3ua(SGSN1)> 12. acc <target m3ua(SGSN1)> setAutoActivate
13. lst M3uAssociation=<target m3ua(SGSN1)>14. acl <target m3ua(SGSN2)> 15. acc <target m3ua(SGSN2)> setAutoActivate16. lst M3uAssociation=<target m3ua(SGSN2)>
17. alt18. lst ranap19. lk Ranap=<target ranap>
20. u+ ranap_rec21. del ranap=<target ranap>22. u-23. run <created mos>
24. alt25. lst ranap26. lk ranap=<target ranap>
8.11 WA for Synchronization alarms from DUW sites(RBS operation)1. alt2. sget Synchronization3. rm /d/nss_tum_data. 4. cvls5. acc 0 manualrestart6. alt7. sget Synchronization
8.12 WA for DISABLED cells without alarm after upgrade1. st utarncell=<target sites>
(Optional)lh <MOD> te e trace1 trace6 trace7 DLCODE_CELLlh <MOD> te e trace3 trace6 trace7 HSDSCH_CONFIG_CELL
lh <MOD> te e trace5 trace6 trace7 rnhCellRoC[<CELL_RO>]lh ommp te e trace6 trace7 roamFroUtranCellRoProxyC lh ommp te e trace6 trace7 roamFroHsdschRoRnhProxyClh <MOD> cellenable -cid <CELL_ID>
lh <MOD> rrt-RncLmCell info 1/1/1/1/2/1.<CELL_CAPS>/6 lh <MOD> rrt-RncLmCell history 1/1/1/1/2/1.<CELL_CAPS>/6 lh <MOD> rrt-RncLmCell system 1/1/1/1 lh <MOD> rrt-RncLmCell getattr 1/1/1/1/2/1.<CELL_CAPS> cellAlarmList lh <MOD> rrt-RncLmCell history 1/1/1/1/2/1.<CELL_CAPS>fget <AFFECTED_HSDSCH> froId
<MOD>, <CELL_ID>, CELL_CAPS> - on cedr printout pick affected cell and use values from proper columns: <MOD> - 'MOD' column <CELL_ID> - 'cid' column<CELL_RO> - value from 'ro' column <CELL_CAPS> - 'ro' column increased by 1 ('ro' + 1)
After finished taking the log, need to disable tracesh <MOD> te d trace1 trace6 trace7 DLCODE_CELLlh <MOD> te d trace3 trace6 trace7 HSDSCH_CONFIG_CELL lh <MOD> te d trace5 trace6 trace7 rnhCellRoC[<CELL_RO>]lh ommp te d trace6 trace7 roamFroUtranCellRoProxyC lh ommp te d trace6 trace7 roamFroHsdschRoRnhProxyClh <MOD> celldisable -cid <CELL_ID>
2. bl <target hsdsch>3. deb <target hsdsch>4. bl <target utrancell>5. deb <target utrancell>
6. lbl <target utrancell>7. deb <target commonCH>8. deb <target utrancell>9. deb <target hsdsch>10. deb <target eul>
11. bl <target hsdsch> <target Eul>12. u+13. del <Eul on target cell>
14. del <Hsdsch on target cell>15. u-16. run <created mos>17. deb <target hsdsch> <target Eul>
18. cvls19. acc 0 manualrestart
20. strt21. acc mod<target mod> manualrestart22. st utrancell
8.13 WA for RBS alarm 乬 Carrier_RejectSignalFromHardware 乭(RNC)1. lt ^utrancell|fach|rach|^pch|hsdsch|eul2. lst utrancell=<target site>3. alt(RBS)4. alt5. cvls6. acc 0 manualrestart7. cvls(RNC)8. alt9. lst utrancell=<target site>(RBS)10. alt
8.16 WA for RBS alarm NodeSynch_Phase_Difference_Measurement_Failed
1) Check if the alarm appeared from all RBS or not. - If all the alarm appears from all RBS, Restart active TUB borad.cabbl 000400st 000400
acc 000400 manualrestart
2) Check which subracks the impacted RBS refer to.strtsget IubLink=XXX|XXX|XXX rncModuleRef(XXX = iublink name)st modX ##orstd
3) Check which Ccdevices the impacted RBS usecedr | sort -k 27 | egrep -i "XXX|XXX|XXX"(XXX = cell name)
- If the impacted RBS use a same Ccdevice, restart SPB board which has the Ccdevicebl (target board name)st XXXacc XXX manualrestart
4) Check if the impacted RBS are ATM RBS or IP RBS.strt -s XXXXXX = ms, es-1 (target subrack)
8.17 Check and WA for WCDMA carrier issue1. shget wcdmacarrier2. ex) perl ichigo_wcdmacarrier_detection_paX.pl -rnc krnc569 -carrier 5,6Tokyo, tp03) cd /home/tpuser/users/emotshi/111124_TRNC83_wcdmacarrier/ perl ichigo_wcdmacarrier_detection_pa7.pl -rnc trncxx -carrier 5,6
######not confirmed below yet #####################Tokai, tp03) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc crncxx -carrier 5,6Kansai,tp01) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc krncxx -carrier 5,6###################################################
3. tpuser@nrjtotp03 trnc83]$ gzip -dc 2011-11-25_120* |
/opt/tools/decoder/3.1t/decoder/concat_segmented_rlib_traces.pl | grep -i wcdmacarrierex)[2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 4 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 5
4. ex) perl ichigo_wcdmacarrier_remedy_paX.pl -rnc krnc569 -carrier 1,2,3,4,5,6Tokyo, tp03) perl ichigo_wcdmacarrier_remedy_pa4.pl -rnc trncxx -carrier 1,2,3,4,5,6
######not confirmed below yet #####################Tokai, tp03) perl ichigo_wcdmacarrier_remedy_pa4.pl -rnc crncxx -carrier 1,2,3,4,5,6Kansai,tp01) perl ichigo_wcdmacarrier_remedy_pa4.pl -rnc krncxx -carrier 1,2,3,4,5,6###################################################
5. ex) perl ichigo_wcdmacarrier_detection_paX.pl -rnc krnc569 -carrier 1,2,3,4,5,6Tokyo, tp03) cd /home/tpuser/users/emotshi/111124_TRNC83_wcdmacarrier/ perl ichigo_wcdmacarrier_detection_pa7.pl -rnc trncxx -carrier 1,2,3,4,5,6
######not confirmed below yet #####################Tokai, tp03) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc crncxx -carrier 1,2,3,4,5,6Kansai,tp01) cd /home/tpuser/users/ichigo perl ichigo_wcdmacarrier_detection_pa6.pl -rnc krncxx -carrier 1,2,3,4,5,6###################################################
6. tpuser@nrjtotp03 trnc83]$ gzip -dc 2011-11-25_120* | /opt/tools/decoder/3.1t/decoder/concat_segmented_rlib_traces.pl | grep -i wcdmacarrierex)[2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 1 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not
retrive data from config for FRO id = 2 [2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 3 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 4 [2011-11-25 03:04:47.832] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 5 [2011-11-25 03:07:31.380] 010200/RncLmUePT(uehUeCtxtFroObjectWcdmaCarrierC) ../src/UehUeCtxtFroObjectWcdmaCarrierC.cpp:140 ERROR:setWcdmaCarrierValidData(): could not retrive data from config for FRO id = 6
7. shget wcdmacarrier