Davies Supply Group Ltd. Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433 Flame Safeguard Davies Is Your Authorized Fireye & Honeywell Burner Management Controls Distributor Honeywell RM7800 Series Relay Modules Fireye M Series II Chassis Sub-bases Purge Cards Flame Amplifiers Keyboard Display Modules Communications Controls Programmer Modules Reset Switches Expansion Modules Infrared Scanners UV & Vacuum Tubes We carry a full line of Burner & Boiler Controls & related Flame Safeguard Products including: A190 31/01/14

Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Embed Size (px)

Citation preview

Page 1: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard

Davies Is Your Authorized Fireye & Honeywell Burner Management Controls Distributor

Honeywell RM7800 Series Relay Modules

Fireye M Series II Chassis

Sub-bases Purge Cards Flame Amplifiers Keyboard Display Modules Communications Controls

Programmer Modules Reset Switches Expansion Modules Infrared Scanners UV & Vacuum Tubes

We carry a full line of Burner & Boiler Controls & related Flame Safeguard Products including:

A190 31/01/14

Page 2: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Microprocessor-based integrated flame switch for detecting a flame using rectification, ultraviolet (UV) or infrared (IR) source

Three LEDs to indicate power, flame and alarm Access for external electrical voltage checks Non-volatile memory Shutter drive output Honeywell RM7800 Series

Flame Safeguard - 7800 Series Relay Modules

Flame Switch

Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications

Five LEDs provide sequence information Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after

power loss Selectable relight or lockout on loss of flame Honeywell RM 7800 Series

On-Off Primary Control

Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications

Five LEDs provide sequence information Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after

power loss Selectable relight or lockout on loss of flame Airflow switch check Honeywell RM7800 Series

On-Off Primary Control with Purge

A191 04/29/05

Contact Davies Experts For Details & Proper Application

Page 3: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications

Functions include automatic burner sequencing, flame supervision, system status indications, system or self-diagnostics and troubleshooting

Access for external electrical voltage checks Five LEDs provide sequence information Five function Run/Test switch Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after

power loss Selectable AirFlow switch check Honeywell RM7800 Series

Flame Safeguard - 7800 Series Relay Modules

Programmer

Microprocessor-based integrated primary burner control with pilot hold function for industrial semi-automatically fired gas, oil, coal or combination fuel single burner applications

C alarms only on safety shutdown and requires ST7800C purge timer Access for external electrical voltage checks Five LEDs provide sequence information Five function Run/Test switch Interchangeable plug-in flame amplifiers Local or remote annunciation of operation and fault information Nonvolatile memory retains history files and sequencing status after

power loss Pilot valve hold function requires plug-in flame signal amplifier Honeywell RM7800 Series

Programmer - Manual Start Industrial

Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications

Functions include automatic burner sequencing, flame supervision, system status indications, system or self-diagnostics and troubleshooting

Access for external electrical voltage checks Application flexibility and communication interface capability Five LEDs provide sequence information Five function Run/Test switch Interchangeable plug-in flame amplifiers Nonvolatile memory retains history files and sequencing status after

power loss Selectable AirFlow check Honeywell RM7800 Series

Programmers with Annunciator

A192

Contact Davies Experts For Details & Proper Application

Page 4: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard - 7800 Series Required Components

Support remote mounting of S7800 keyboard display module, personal computer communications interface and remote reset

Use with remotely mounted S7800 keyboard display module Installs directly on front of 7800 series relay modules Honeywell S7800 Series

Data ControlBus™ Module

For select 7800 series relay modules Honeywell S7800 Series

Keyboard Display Module

Microprocessor-based expanded Annunciator to support the 7800 series relay modules for first-out annunciation, sequencing, system or self-diagnostics and troubleshooting

Twenty-six status LEDs Front panel LED array-arranged to indicate flow of line-voltage

through string of limits, controls and interlocks Selectable current and first-out LED array display status Twenty-one monitored contact points Access for external electrical voltage points Honeywell S7800 Series

Annunciator - First Out Expanded

A193

Contact Davies Experts For Details & Proper Application

Page 5: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Burner, panel or wall mount subbases for relay modules or expanded Annunciator Makes electrical connections through bifurcated contacts Provides terminals for field wiring Twenty-two terminals Honeywell Q7800 Series

Terminal Universal Wiring Subbases

Flame Safeguard - 7800 Series Required Components

Provides the prepurge timing for select 7800 series relay modules Honeywell ST7800 Series

Plug In Purge Timers

Serves as link between remote pushbutton and relay module Reset button can be installed up to 1000' away Installs directly on front of 7800 series relay modules Honeywell S7800 Series

Remote Reset Module

A194

Panel Mount

Burner/Wall Mount

Contact Davies Experts For Details & Proper Application

Page 6: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard - 7800 Series Part & Accessories

7800 Series - Parts & Accessories Description Application Brand Part Number

Carrying Case For S7800 Display Honeywell 206311

ControlBus™ Module 3-Wire Electrical Connector For S7800 Display Honeywell 203541

Display Extension Cable - 60 inches For S7800 Display Honeywell 221818A

Dust Cover For 7800 Relay Modules Honeywell 221729A

Nema 1 Cover Assembly For Mounting S7800 Display Honeywell 204718B

Nema 4 Cover Assembly with Reset Button For Mounting S7800 Display Honeywell 204718C

Plug-in Power Supply (13 Vdc) For Remote Mounting S7800 Display Honeywell 203968A

Remote Mounting Bracket For S7800 Display Honeywell 203765

Solid State Ignition Transformer For use only in interrupted ignition applications and used

with C7027, C7035 or C7044 Minipeeper Ultraviolet flame Detectors

Honeywell Q624A1014

Terminal Slot Cover For Q7800 Honeywell 221779

A195

203968A

204718B

204718C

221729A

221818A Q624A1014

203541

Contact Davies Experts For Details & Proper Application

Page 7: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Amplifiers - 7800 Series Required Components

Solid State plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 series relay modules

Flame signal strength ranges from 0.0 to 5.0 Vdc Plug into 7800 relay module through printed circuit board edge

connector keyed for proper orientation Flame signal test jacks to measure amplifier flame signal voltage Color-coded label identifies flame detection type Honeywell R7800 Series

Flame Signal Amplifiers

Type Color Flame Failure Response Time

Self Checking Description Brand Part Number

Infrared Red 2.0 sec or 3.0 sec None Use with Flame Sensor: Gas, Oil, Coal: Infrared (lead sulfide) C7015

Honeywell R7848A1008

Infrared Red 2.0 sec or 3.0 sec Ampli-check Use with Flame Sensor: Gas, Oil, Coal: Infrared (lead sulfide) C7015

Honeywell R7848B1006

Rectification Green 0.8 sec or 1.0 sec None Use with Flame Sensor: Gas: Rectifying Flame Rods C7004, C7005, C7007, C7008,

C7009, Q179

Honeywell R7847A1025

Rectification Green 2.0 sec or 3.0 sec None Use with Flame Sensor: Gas, Oil, Coal: Ultraviolet Flame Sensor C7012A,C or

Gas: Rectifying Flame Rods C7004, C7005, C7007, C7008, C7009, Q179

Honeywell R7847A1033

Rectification Green 2.0 sec or 3.0 sec Dynamic Self-Check

Use with Flame Sensor: Gas, Oil, Coal: Ultraviolet Flame Sensor C7012E,F

Honeywell R7847C1005

Ultraviolet Purple 0.8 sec or 1.0 sec None Use with Flame Sensor: Gas, Oil: Minipeeper C7027A, C7035A, C7044

Honeywell R7849A1015

Ultraviolet Purple 2.0 sec or 3.0 sec None Use with Flame Sensor: Gas, Oil: Minipeeper C7027A, C7035A, C7044

Honeywell R7849A1023

Ultraviolet Purple 2.0 sec or 3.0 sec Ampli-check Use with Flame Sensor: Gas, Oil: Minipeeper C7027A, C7035A, C7044

Honeywell R7849B1021

Ultraviolet Blue 2.0 sec or 3.0 sec Dynamic Self-Check

Use with Flame Sensor: Gas, Oil, Coal: Adjustable Sensitivity Ultraviolet Flame

Sensor C7076

Honeywell R7886A1001

A196

Contact Davies Experts For Details & Proper Application

Page 8: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

A196-1 04/29/05

Flame Safeguard - ControLinks™ - 7999 Series

Simultaneously controls up to four actuators When used with the ML7999 Universal parallel positioning actuator,

it represents a value added replacement of mechanical cam and linkage assembly controlling the relationship between fuel, airflow and flue gas recirculation (if used) on a power burner.

Power Input: 100 to 120 Vac (+10/-15%), 50/60Hz (±10%) Maximum Power Consumption: 10VA With one communications port the R7999 provides communications

capabilities similar to those found in the 7800 series controls Required Components: R7999 fuel air controller, Q7999 wiring

subbase, ML7999 universal parallel positioning actuator & ZM7999 software configuration tool

Honeywell R7999A series

ControLinks™ Fuel Air Control System - Fuel Air Controller

Provides 100lb-in torque, pulse-width-modulating (PWM) control of combustion air dampers, butterfly has valves, oil modulation valves and flue gas recirculation systems.

Must be used with the R7999 Fuel Air Controller Password protected with an eight digit hexadecimal identifications

signal Couples directly to a 1/2" shaft with no additional parts required Power Input: 100 to 240Vac +10/-15%, 50/60Hz Maximum Power Consumption: 15VA Enclosure: NEMA2/IP50 Honeywell ML7999A series

ControLinks™ Fuel Air Control System - Universal Parallel-Positioning Actuator - 7999 System Required Component

Contact Davies Experts For Details & Proper Application

Page 9: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Amplifiers - BC7000/R4140 Amplifiers

Solid state plug-in amplifiers respond to flame detector signal and indicate presence of flame Use with BC7000; R4075C,D,E; R4138C,D flame safeguard controls and appropriate flame detector and FSP5075A1,

FSP5075A3 flame amplifier modules Honeywell R7200 Series

Flame Amplifiers

Solid state, plug-in units allow use of rectification flame detection Use with R4795A,D flame safeguard primary controls and appropri-

ate flame detector Honeywell R7200 Series

Flame Safeguard Amplifiers

A197

R7247C1001 R7249A1003

R7289A1004

Contact Davies Experts For Details & Proper Application

Page 10: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Detectors - Infrared Flame Sensors

C7015A combination mount and 104662B and D plug-in lead sulfide cell senses infrared radiation from gas, oil, coal or dual-fuel flames

Used for combination or dual-fuel applications Detects pilot and main flame Mounts quickly and easily on a standard 3/4" sighting pipe Works where flame rod or rectifying photocell mounts are difficult to apply Includes 110634A bushing with magnifying lens and 105134-00021 orifice Uses photoconductive lead sulfide cells 104662B and D Honeywell C7000 Series

Infrared (Lead Sulfide) Flame Detector

Solid state electronic flame detectors for use with Honeywell flame safeguard controls and amplifiers

Sense ultraviolet radiation produced by combustion of gas, oil, coal or other fuels

Replace C70123 vacuum tube models Mount horizontally, vertically or at any angle in between Provide quick electrical hookup with threaded conduit fitting and

color coded wires Reduced nuisance shutdowns by wiring two in parallel Honeywell C7000 Series

Solid State Purple Peeper™ Ultraviolet Flame Detector

Minipeeper™ Ultraviolet Flame Detector

A198

C7027A1023/1031

C7027A1049

Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers

Applications include coal, gas and oil fired burners Use on Honeywell flame safeguard primary safety controls and

burners requiring ultraviolet flame detection Mounts on a 1/2" sighting pipe by using an integral collar Can be wired in parallel for difficult sighting applications Seals against pressures as high as 5 psi when correctly installed Allows for blast tube mounting due to compact size Vibration 0.5 G max Electrical Connections: 2 NEC Class 1 leadwires Used With Flame Amplifiers:

R7249A, B, R7849A ,B ,R7749B, R7259, R7290 Honeywell C7027A Series

07/12/12

Contact Davies Experts For Details & Proper Application

Page 11: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Compact flame detector for use with flame safeguard controls with ultraviolet amplifiers

Use on Honeywell flame safeguard primary safety controls and burners requiring ultraviolet flame

Mounts on a 1/2 sighting pipe by using an integral collar Protect the sensing tube with a shield Wires in parallel for difficult sighting applications Seals against pressures as high as 5 psi when correctly installed Field replaceable ultraviolet sensing tube Honeywell C7000 Series

Minipeeper™ Ultraviolet Flame Detector with Shield

Flame Detectors - Infrared Flame Sensor

Flame Detector Parts - 7800 Series

Description Application Brand Part Number

1/2" Internal to 1/2" External Adapter For C7015 Honeywell 133711

Ant-Vibration Mount For C7012, C7024 or C7061 Honeywell 123539

Bulk Pack - 20 psi Window For C7012E, F; C7024; C7061 Honeywell 114372

Kanthal Flame Rod - 18" For C7007A, C7011A Honeywell 102709B

Kanthal Flame Rod - 24" For C7008 Honeywell 105478D

Kanthal Flame Rod - 48" For C7007A, C7011A Honeywell 102709E

Lead Sulphide Cell, Medium Sensitivity For C7015 Honeywell 104662B

Lead Sulphide Cell, High Sensitivity For C7015 Honeywell 104662D

Swivel Mount For C7012, C7015, C7024, C7027, C7035, C7061, C7076 Honeywell 118367A

UV Power Tube (-40 to 250F) For C7035, C7061 Honeywell 129464N

UV Sensing Tube For C7012, C7024 Honeywell 113228

Vacuum Tube For C7012 Honeywell 113236

A199

104662B 104662D 113228 114372 129464N 133711

102709B 102709E 105478D

Contact Davies Experts For Details & Proper Application

Page 12: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard - Network Interface - Data Acquisition

A200

Allows remote monitoring and diagnostics of the BCS7700 or 7800 series relay modules

Provides local and remote annunciation of 7800 series and BCS7700 faults

Up to six ControlBus™ modules per network interface unit Modular construction, NEMA 1 rated enclosure

Network Interface ControlBus™ Modules

Description PC Requirements Brand Part Number

Network Interface ControlBus™ Module for use with RM7800

series

486 IBM™ compatible personal computer and ZM7850A

combustion system manager Honeywell QS7800A1001

Allows remote monitoring and diagnostics of the BCS7700 or 7800 series with an IBM™ compatible personal computer

Connects with GCS7700s or 7800 series systems Auto-dialout on BCS7700 or 7800 series faults up to three telephone

numbers Access control, password protection Dialout override for service alarms Internal software clock for date and time stamping of faults Light emitting diode (LED) status indication Modular construction. On-line data logging Personal computer interface; user friendly and menu driven

Network Interface Unit

Weight PC Requirements Brand Part Number

4 lbs, 10 oz. 2.l kg

486 DX2 66 MHz IBM™ compatible. 16 MB memory, 50 MB available hard disk space, 2X CD-ROM drive, Super VGA color

monitor, 3.5" diskette drive, serial port for modem, mouse or touch screen, parallel port for printer, printer, keyboard

Honeywell Q7700A1014

Electrical Ratings

120 Vac

Description Brand Part Number

ControlBus™ Module 3-Wire Electrical Connector

Honeywell 203541

Network Interface Parts

Page 13: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard - Primary Controls

A201

Provides solid state, electronic flame safeguard protection for industrial and commercial single or dual fuel burners

Uses rectification principle of electronic flame detection Relights once after flame failure in attempt to re-establish pilot before

lockout. Safe-start check prevents start-up if flame-simulating failure occurs in flame detector circuit

Includes built-in protection against ignition crossover in flame rods and SPDT alarm contacts

Solid state circuitry Mounts and removes easily through use of captive mounting screws Mounting base is made of strong thermoplastic

RA890F Protectorelay™ Primary Control - Rectification

Electrical Rating Flame Failure Response Time

Safety Switch Timing

Description Brand Part Number

120 Vac 0.8 sec 15 sec Rectification, with alarm contacts Honeywell RA890F1270

120 Vac 3.0 sec 15 sec Rectification, with alarm contacts Honeywell RA890F1288

120 Vac 3.0 sec 30 sec Rectification, with alarm contacts Honeywell RA890F1346

240 Vac 3.0 sec 15 sec Rectification, with alarm contacts Honeywell RA890F1387

Prepurge timer for R4795 Control Systems

Provides solid state, electronic flame safeguard protection for com-mercial and industrial single or dual fuel burners

Use with rectification or ultraviolet type flame detectors depending on the interchangeable, plug-in amplifier being used

Recycle once after flame failure in attempt to re-establish pilot before lockout

Include manual push-to-reset safety switch in a dust-resistant enclosure

Includes SPDT alarm contacts

Primary Control

Connections Description Brand Part Number

Alarm contacts: male quick connect terminals

120V 50/60 HZ less Amplifier and Prepurge

Timer Honeywell R4795A1016

Prepurge Timer

Purging Time Brand Part Number

Honeywell ST71A1000 7 sec

30 sec Honeywell ST71A1018

60 sec Honeywell ST71A1026

90 sec Honeywell ST71A1034

Page 14: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard - Primary Controls

A202

Used with RA890 and R4795 controls Serves as junction box for connecting to external circuits Contains terminal blocks with coded terminals and screws

Provides solid state, electronic flame safeguard protection for industrial and commercial single or dual fuel burners

Designed for interrupted ignition with intermittent pilot on gas burners, and interrupted or intermittent ignition on oil burners

Use with a C7027, C7035 or C7044 Minipeeper™ ultraviolet flame detector for flame sensing

Relights once after flame failure in attempt to re-establish pilot before lockout

Solid state circuitry, eliminates warm-up and increases resistance to vibration

RA890G Protectorelay™ Primary Control - Ultraviolet

Electrical Rating Flame Failure Response Time

Safety Switch Timing

Description Brand Part Number

120 Vac 0.8 sec 15 sec Ultraviolet, with SPDT alarm contacts Honeywell RA890G1229

120 Vac 3.0 sec 15 sec Ultraviolet, with SPDT alarm contacts Honeywell RA890G1260

Wiring Mount Base

Description Brand Part Number

Wire Mounting Base for RA890 & R4795 controls Honeywell Q270A1024

Page 15: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Intelligent microcomputer-based integrated control system for automatically fired commercial and industrial single burner applications Requires a PM720G,L or M program module

Provides higher levels of protection than conventional flame safeguard programmers to reduce service, maintenance, downtime and energy costs

Referred to as the Blue Chip because of its computer "chip" technology and its distinctive blue color Directly replaces R4150 and R4140 in most applications: mounts directly on the same Q520A subbase. Sequences

burner motor, firing rate motor (PM720G and L models only), ignition, pilot valve and main fuel valve(s). Safety shutdown on flame failure (lockout). Ten second pilot flame establishing period. Flame failure response time: 2-4 seconds. Lockout switch timing: less than 1 second

Features Dynamic Self-Check Logic - Provides Safety Improvement A major breakthrough in safety through advanced microcomputer technology has allowed the extension of the original Honeywell Dynamic Self Check/Max Safety concept (formerly restricted to the flame detection circuit) to the basic program logic system - Dynamic Self Check Logic is a comprehensive family of unique safety provi-sions that continuously monitors the total system performance to provide the highest degree of safety available Annunciation and Self Diagnostics - Cut Service Costs With "Plug-Instantly" burner system startup, control, troubleshooting and repair have never been easier. Integral first-out annunciation and self-diagnostic functions reduce service costs and minimize the inconvenience and cost associated with downtime. These important new features are called "Plug-Instant" , because they are a standard provision of the BC7000 system - no additional hardware need to be purchased or installed or maintained Energy Saving Innovations - Reduce Fuel Consumption Unnecessary purge-related heat losses are minimized by innovative BC7000 system program logic provisions. Microcomputer intelligence is employed to reduce fuel consumption by optimizing the pre-purge and terminating wasteful blower operation when the system encounters an inoperative field interlock. This condition can cause con-ventional sequences to permanently stall in an unproductive purge Universal System Chassis - Minimizes Inventory Investment Now, through the flexibility of microcomputer technology, a single control chassis can be universally applied to perform any standard burner program. Solid state program modules plug in to implement the required burner se-quence of operation, timings and desired features. The universal BC7000 system chassis allows you to cover the full range of applications, supports, standardization and minimizes inventory investment

"Blue Chip" Microcomputer Burner Control System

Flame Safeguard - Programmers

Description Brand Part Number

Use with PM720G,L or M program module, R7247, R7248, R7249 or R7476 amplifier and matching rectification, infrared, or ultraviolet flame detector. Mounts on Q520A mounting subbase

Honeywell BC7000L1000

A203

Page 16: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Flame Safeguard - Programmer Controls

A204

Plug-in programming module designed to provide burner program sequence, timing and features for BC7000 universal system

Selectable AirFlow check Features: Pre-ignition running and low fire interlocks 5 Second early spark termination Interrupted Pilot 15 Second Postpurge Pre-ignition 60 Hz Frequency

Bag Assembly for Fireye to R4140 conversion

Programming Module

Description Flame Establishing Period

Brand Part Number Pilot Main

Program Module, LHL, Proven Low Fire PrePurge 40 sec 10 sec 10 sec Honeywell PM720G2005

Program Module, On-Off, Proven Low Fire 30 sec 90 sec 10 sec 10 sec Honeywell PM720M2002

PrePurge

Programmer Control Parts

Description Brand Part Number

Includes adapter, cover insert, 2 plugs and #8-32 screw Honeywell 4074BZU

Page 17: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Designed as a replacement for the Fireye M1 Series "relight" controls Provides ignition and flame safeguard for heating or process light oil

or gas fired burners Programmer module should be selected based on the type of flame

failure response time Fireye M Series II

Amplifier module should be selected based on the type of flame failure response time

Fireye M Series II

Designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process burners that use gas and/or light oil fuels

In the event of ignition failure, or following a safety shutdown, the unit locks out, activating an alarm circuit. Reset is required

Controls incorporate a safety checking circuit that is operative on each start. If flame (real or simulated) is detected prior to start or during e purge, the fuel valves will not be energized, and the unit will lock out

Replaceable fuse Fireye M Series II

Flame Safeguard - M Series II

Chassis

Amplifiers

Programmer Modules

A205 31/01/14

Contact Davies Experts For Details & Proper Application

Page 18: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

A compact, microprocessor based, modular burner management system designed to provide automatic ignition and continuous flame monitoring for commercial sizes of heating and process equipment firing any type of fuel

Designed to be backward compatible with existing M-Series controls Advantages are zero dependence on discrete components previously

used for timing functions Fireye Micro M Series

Flame Safeguard - Micro M Series

Chassis

Amplifier module should be selected based on the type of flame failure response time and type of flame scanner

Fireye Micro M Series

Amplifiers

Programmers are micro-controller based modules that control the sequence of operation and also interface with plug-in amplifiers

LED indicators on the programmer modules indicate the current operating status of the control and during a lockout condition displays the fault as a coded sequence

Fireye Micro M Series

Programmer Modules

The reset switch will force the Micro M to recycle if depressed and released during the purge or run period

Fireye Micro M Series

Reset Switch

A206 31/01/14

Contact Davies Experts For Details & Proper Application

Page 19: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Amplifier module should be selected based on the type of flame failure response time and type of flame scanner

Fireye E Series

Provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas and combination fuel burners

On a safety shutdown, the display module will advise the operator that the control is in "lockout" and indicate the cause as well as the position in the operating sequence that it occurred

Fireye E Series

Flame Safeguard - E Series

Chassis

Amplifiers

Provides both current and historical information pertaining to the operation of the control

This module is a 2 line by 16 character LCD with keypad Mounts directly onto the front face of the EP and EPD style programmers RJ style connector for connection to the EP and EPD style programmers Fireye E Series

The functional operation, flame failure response time, purge timings, firing rate motor circuit, trial for ignition timings, recycling function and display messages are determined by the programmer

Take note of the programming sequence chart for each programming module for the proper explanation of prepurge timings

Fireye E Series

Programmers

Display Modules - LCD

A207 31/01/14

Contact Davies Experts For Details & Proper Application

Page 20: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

The E500 display module can be remotely mounted in the ED400 remote display housing in either of two ways; as a stand alone unit or flush mounted to a panel

The ED400 is a two piece rigid plastic assembly with mounting holes and comes with a right angle plug adapter for easy

Fireye E Series

Flame Safeguard - E Series

Remote Display Housing

Ribbon cable for connecting the E300 expansion module to any EB700 chassis

Fireye E Series

Provides an easy, efficient method to panel mount the ED510 display module.

Kit contains a mounting plate, gasket, two 8-32 x 1 1/4" mounting screws, and ED58-8 cable

Fireye E Series

Provides increased interlock supervision capability of the FLAME- MONITOR™ system. It connects to any EB700 chassis by means of a ribbon cable

The module does not interfere with the normal operation of the FLAME-MONITOR™ system, it expands the message and diagnostic capability

Provides operational information and reduces troubleshooting time by identifying the specific limit in the operating control circuit and running interlock circuit which caused the burner to shutdown or lockout

Fireye E Series

Expansion Module

Expansion Module Cable

Remote Display Mounting Kit

A208 31/01/14

Contact Davies Experts For Details & Proper Application

Page 21: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Plug-in amplifier modules permit the selection of flame detection method

Meter test jacks on each amplifier module provides flame single readout with a DC voltmeter

Fireye D Series

Flame Safeguard - D Series / M Series (Old Style)

Amplifiers

Solid state programmer is a plug-in module A test switch permits the operator to stop the start-up programming

prior to energizing the main fuel valves, for test purposes Fireye D Series

Programmer Module

Designed for heating or automatically ignited process burners using light oil, gas or combination light oil/gas fuels (single or multiple burner installations)

Controls monitor pilot and main flames Fireye M Series (Old Style)

Chassis

A209 01/02/08

Contact Davies Experts For Details & Proper Application

Page 22: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Replacement cell for Infrared scanners

Has rugged die cast housing that mounts on pipe with setscrew Vertical mounting of UV tube provides greater sensitivity UV tube is replaceable Scanner is non self-checking Fireye 45UV Series

Designed to detect low frequency IR signals from gas or oil flames Mounting collar is 1/2" NPT Fireye 48PT Series

Flame Safeguard - Cells, Tubes & Scanners

Cells

Scanners - Infrared

Scanners - Ultraviolet - Standard

Scanners - UV - Self-Check

A210

For continuously fired applications where recycling is infrequent or absent The self-checking circuit checks the electronics and the UV tube for

proper operation every six seconds during the firing period Suitable for fuel gases and oil Replaceable UV tube Mounting 1" NPT

Description Brand Part Number

UV Self-check scanner with 8 foot lead. Use w/P-Series Fireye 45UV5-1005

UV Self-check scanner with 8 foot lead. 1" NPT threads. 120 VAC shutter. Use w/EUVS4, 72DUVS4 or 72DUVS1T

Fireye 45UV5-1009

UV Self-check scanner with 8 foot lead. 1" NPT threads. Preferred Scanner

Fireye 45UV5-1000

45UV5-1009 45UV5-1000

31/01/14

Contact Davies Experts For Details & Proper Application

Page 23: Davies Is Your Authorized Fireye & Honeywell Burner ... · PDF fileDavies Is Your Authorized Fireye & Honeywell Burner Management ... Microprocessor-based integrated primary burner

Davies Supply Group Ltd.

Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377 (403) 244-2161 (403) 381-7707 (306) 933-2433

Miniature non self-checking scanners used in applications where scanners to flame distance does not exceed 20"

Suitable for fuel gases and number 2 oil Non-replaceable tube 1/2" NPT mounting collar Fireye UV1A Series

Flame Safeguard - Cells, Tubes & Scanners

Scanners - UV - Miniature

Tubes - UV

Description Brand Part Number

For 45UV5 scanners Fireye 4-320-1

Replacement UV tubes

Tubes - Vacuum

Replacement UV tubes

A211

Description Brand Part Number

Vacuum tube, 12SN-GT for 26SJ5, 26RJ8, 26UJ5, 29RF5-1000 series, F18T3, 47FU9, 27VH6

Fireye 4-84

Vacuum tube, 12AX7, 26RJ8, 26SJ5 and 29RF5 Fireye 4-91

Vacuum tube, 12H6, 26SJ5, 26RJ8, 26UJ5, 29RP5-1000 series

Fireye 4-98

Vacuum tube 12SL7GT, 26RJ8, 26SJ5, 29F5-1000 series Fireye 4-100

Vacuum tube 12BH7A, 26RJ8, 26SJ5, 29RF5, all 5000 and 6000 series

Fireye 4-204

31/01/14

Contact Davies Experts For Details & Proper Application