2
www.Prosurge.com Part No. Pole Nominal Voltage (Vdc) Max. Permitted DC Voltage, Vpvdc (V) Nominal Discharge Current, In (8/20μs) (kA) Max. Discharge Current, Imax (8/20μs) (kA) Voltage Protection Rating, VPR (kV) SCCR Rating (kArms) Type 1ca Type 2ca SPV48-V-S SPV48-V-S/C 1 48 85 20 50 0.4 30 SPV500-V-S SPV500-V-S/C 1 500 560 20 50 1.5 100 SPV600-V-S SPV600-V-S/C 1 600 670 20 50 1.5 50 Part No. Pole Nominal Voltage (Vdc) Max. Permitted DC Voltage, Vpvdc (V) Nominal Discharge Current, In (8/20μs) (kA) Max. Discharge Current, Imax (8/20μs) (kA) Voltage Protection Rating, VPR (kV) SCCR Rating (kArms) Type 1ca Type 2ca SPV48-V-C-S SPV48-V-C-S/C 2 48 85 20 50 0.4 30 SPV500-V-C-S SPV500-V-C-S/C 2 500 560 20 50 1.5 100 SPV600-V-C-S SPV600-V-C-S/C 2 600 670 20 50 1.5 50 Dimension drawing Basic circuit diagram Dimension drawing Basic circuit diagram Prosurge SPV series is a Type 1CA SPD according to UL 1449 4th, designed for Photovoltaic system DC-side protection against the damage from surges caused by lightning and other electrical sources. V Configuration protection Single mode or I Configuration protection DC Power / Photovoltaic System SPDs SPV Rating: Max. permitted DC voltage (Vpvdc): 85V~1500Vdc Surge capacity (8/20μs): 50kA Short circuit current rating (SCCR): 100kArms - tested without external CB or fuse Technical Features: UL recognized Type 1CA SPD (ANSI/UL1449 4th), Type 2CA SPD (CSA-C22.2 ) for PV/ Photovoltaic system. (UL File No. E319871). Pluggable design with window fault indication Remote alarm signal optional Meet worldwide standards of UL 1449-4th, IEC 61643-31:2018 & EN50539-11:2013 Global patented thermal disconnector design with arc extinguishing device, fail-safe & self-protected, quick thermal response and perfect circuit cutoff function. No additional over-current protection devices required. Maximum Safety in Surge Protection 35

DC Power / Photovoltaic System SPDs SPV · Prosurge SPV series is a Type 1CA SPD according to UL 1449 4th, designed for Photovoltaic system DC-side protection against the damage from

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: DC Power / Photovoltaic System SPDs SPV · Prosurge SPV series is a Type 1CA SPD according to UL 1449 4th, designed for Photovoltaic system DC-side protection against the damage from

www.Prosurge.com

Part No.

PoleNominal Voltage (Vdc)

Max. Permitted DC Voltage, Vpvdc (V)

Nominal Discharge Current, In (8/20μs)

(kA)

Max. Discharge

Current, Imax (8/20μs)

(kA)

Voltage Protection

Rating, VPR (kV)

SCCR Rating

(kArms)Type 1ca Type 2ca

SPV48-V-S SPV48-V-S/C 1 48 85 20 50 0.4 30

SPV500-V-S SPV500-V-S/C 1 500 560 20 50 1.5 100

SPV600-V-S SPV600-V-S/C 1 600 670 20 50 1.5 50

Part No.

PoleNominal Voltage (Vdc)

Max. Permitted

DC Voltage, Vpvdc (V)

Nominal Discharge Current, In (8/20μs)

(kA)

Max. Discharge

Current, Imax (8/20μs)

(kA)

Voltage Protection

Rating, VPR (kV)

SCCR Rating

(kArms)Type 1ca Type 2ca

SPV48-V-C-S SPV48-V-C-S/C 2 48 85 20 50 0.4 30

SPV500-V-C-S SPV500-V-C-S/C 2 500 560 20 50 1.5 100

SPV600-V-C-S SPV600-V-C-S/C 2 600 670 20 50 1.5 50

• Dimension drawing • Basic circuit diagram

• Dimension drawing • Basic circuit diagram

Prosurge SPV series is a Type 1CA SPD according to UL 1449 4th, designed for Photovoltaic system DC-side protection against the damage from

surges caused by lightning and other electrical sources.

V Configuration protection

Single mode or I Configuration protection

DC Power / Photovoltaic System SPDs SPV

Rating: • Max. permitted DC voltage (Vpvdc): 85V~1500Vdc

• Surge capacity (8/20μs): 50kA

• Short circuit current rating (SCCR): 100kArms - tested without external CB or fuse

Technical Features: • UL recognized Type 1CA SPD (ANSI/UL1449 4th), Type 2CA SPD (CSA-C22.2 ) for PV/ Photovoltaic system. (UL File No. E319871).

• Pluggable design with window fault indication

• Remote alarm signal optional

• Meet worldwide standards of UL 1449-4th, IEC 61643-31:2018 & EN50539-11:2013

• Global patented thermal disconnector design with arc extinguishing device, fail-safe & self-protected, quick thermal response and perfect

circuit cutoff function. No additional over-current protection devices required.

Maximum Safety in Surge Protection

35

Page 2: DC Power / Photovoltaic System SPDs SPV · Prosurge SPV series is a Type 1CA SPD according to UL 1449 4th, designed for Photovoltaic system DC-side protection against the damage from

www.Prosurge.com

Part No.

PoleNominal Voltage (Vdc)

Max. Permitted

DC Voltage, Vpvdc (V)

Nominal Discharge Current, In (8/20μs)

(kA)

Max. Discharge Current,

Imax (8/20μs)

(kA)

Voltage Protection

Rating, VPR (kV)

SCCR Rating

(kArms)Type 1ca Type 2ca

SPV600-V-CD-S SPV600-V-CD-S/C 3 600 700 20 50 1.8 50

SPV800-V-CD-S SPV800-V-CD-S/C 3 800 920 20 50 2.5 50

SPV1000-V-CD-S SPV1000-V-CD-S/C 3 1000 1120 20 50 2.5 50

SPV1200-V-CD-S SPV1200-V-CD-S/C 3 1200 1340 20 50 3.0 50

SPV1500-V-CD-S SPV1500-V-CD-S/C 3 1500 1500 20 50 4.0 50

Part No.

PoleNominal Voltage (Vdc)

Max. Permitted

DC Voltage,

Vpvdc (V)

Nominal Discharge Current, In (8/20μs)

(kA)

Max. Discharge Current,

Imax (8/20μs)

(kA)

Voltage Protection

Rating, VPR (kV)

SCCR Rating

(kArms)Type 1ca Type 2ca

SPV600-V-CD2-S SPV600-V-CD2-S/C 3 600 700 20 50 1.8 50

SPV800-V-CD2-S SPV800-V-CD2-S/C 3 800 920 20 50 2.5 50

SPV1000-V-CD2-S SPV1000-V-CD2-S/C 3 1000 1120 20 50 2.5 50

SPV1200-V-CD2-S SPV1200-V-CD2-S/C 3 1200 1340 20 50 3.0 50

SPV1500-V-CD2-S SPV1500-V-CD2-S/C 3 1500 1500 20 50 4.0 50

• Dimension drawing • Basic circuit diagram

• Dimension drawing • Basic circuit diagram

2Y Configuration protection

Y Configuration protection

DC Power / Photovoltaic System SPDs SPVMaximum Safety in Surge Protection

36