If you can't read please download the document
Upload
caitir
View
89
Download
1
Embed Size (px)
DESCRIPTION
Electrochemical sensing at Acreo - electrochemistry and impedance Anatol Krozer, Sensor Systems, Göteborg. Hudiksvall ( Optical fibers, R&D and production ). Kista, Stockholm ( Optical Fibers R&D, Nano, SiC ) …. Norrköping ( Printed electronics ). Göteborg, Sensor Systems. - PowerPoint PPT Presentation
Citation preview
PowerPoint Presentation
Electrochemical sensing at Acreo- electrochemistry and impedanceAnatol Krozer, Sensor Systems, Gteborg
Kista, Stockholm (Optical Fibers R&D, Nano, SiC) Norrkping (Printed electronics)Hudiksvall (Optical fibers, R&D and production)Gteborg,Sensor SystemsAcreo, Sensor Systems - people involved
Lei Ye, Keichii Yoshimatsu, - Applied Biochemistry, Lund UnivKristina Reimhult, Lu Sun, Cristina RusuFredrik AhrentorpJakob BlomgrenChrister JohanssonKristina FogelDag IlverAndrea AstalanTorbjrnPetterssonBoris StoevJohn RsvallAKFluid response to variable voltage - global vs local VACIACLocal (at electrodes): artificial biofilm self assembled pH sensitive peptide monolayer
Designed, pH sensitive, thiol terminated peptides well known adsorption properties on the gold surface dense and insulating monolayer is formedC linear = CKHEYKHEYKHEYKHEYKEHEHEHH (-COOH)E - Glutamic acid; C - Cystein; K - Lysine; H - Histidine; Y TyrosinePeptide layer thickness < 50nmThickness changes of few nm can be detectedDetection of small changes of ion concentrationQuantitative detection by data fitting
pH responseGlobal: aging of lubricants for cutting tools at Volvo Skvde plantPlanparallel electrodesPlanar coil
Adding lubrication oilLubricantTwo approaches: plane electrodes: f < 1MHzPlanar coil: f 5MHz Vinnova grant water quality monitoring SensationLocal: Biofouling - capacitive detection
Similar principle applies for planar electrodes facing each other (see previous slide), for the interdigitated finger configuration or for planar coils as shown here.Planar electrodes: Sensing depth is of the order of electrode electrode distance.MIPMIPMIPPassive polymer matrixMIP+Si wafer/glas+-BufferMIPMIPMIPPassive polymer matrixMIPSi wafer/glas-+Example: Milk handling - biofilmMolecularly imprinted polymers on microelectrodes
Polymers with molecular memory artificial antibodiesApplicable mainly to molecules < kDa but imprints of peptides, proteins and even microorganisms are under developmentRobust (shelf life years)Toxins, eg., marine toxins or volatile mould productsNarcoticsChemical warfare agentsExplosivesPeptidesPharmaceutical wasteTannins, coffeinesSugars, (sorbitol, glucose)
AFM170nm S-MIP in PET
2,4m S-MIP particles in PET
SECURITY - Emergency Support System no: 217951
to PCWatersupplyZephyr - measuring ion content and moisture of earth
Results compared with the commercially available sensorDrawbacks (lack of electronics for field conditions)measures only Impedance amplitude! Phase info is lost (but Kramers-Krnig relations are often applicable)Measures only at descrete number of frequencies (here at 2 frequencies) requires extensive calibrations & modelling
Electronics underway (see eg., http://sciospec.de/cms/home)
Similar results for fits with less datapoints
Grant ENV.2012.6.3-1: ZEPHYR no: 308313 Zephyr - Improved model for soil measurements
Grant ENV.2012.6.3-1: ZEPHYR no: 308313 Coil as an electric componentRLCFrequencyR0f < f0 Inductorf > f0Capacitancef